• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4607262)   Today's Articles (3164)   Subscriber (49375)
For: Fontenele RC, Farias Gomes A, Nejaim Y, Freitas DQ. Do the tube current and metal artifact reduction influence the diagnosis of vertical root fracture in a tooth positioned in the vicinity of a zirconium implant? A CBCT study. Clin Oral Investig 2020;25:2229-2235. [PMID: 32827079 DOI: 10.1007/s00784-020-03538-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 08/18/2020] [Indexed: 10/23/2022]
Number Cited by Other Article(s)
1
Gonzalez-Passos T, Barros-Costa M, Oliveira ML, Freitas DQ. Influence of tube current and metal artifact reduction on the diagnosis of external cervical resorption in teeth adjacent to a dental implant in CBCT: an ex-vivo study. Clin Oral Investig 2024;28:356. [PMID: 38834721 DOI: 10.1007/s00784-024-05750-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 05/27/2024] [Indexed: 06/06/2024]
2
Barros-Costa M, Barros-Candido JR, Sampaio-Oliveira M, Freitas DQ, Sverzut AT, Oliveira ML. Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide. Imaging Sci Dent 2024;54:191-199. [PMID: 38948193 PMCID: PMC11211021 DOI: 10.5624/isd.20240016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/26/2024] [Accepted: 04/05/2024] [Indexed: 07/02/2024]  Open
3
Capel CP, da Motta RJG, Pauwels R, Gaêta-Araujo H, Oliveira-Santos C, Tirapelli C. Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography. Dentomaxillofac Radiol 2024;53:233-239. [PMID: 38466923 PMCID: PMC11056797 DOI: 10.1093/dmfr/twae008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 02/13/2024] [Accepted: 02/16/2024] [Indexed: 03/13/2024]  Open
4
Ruiz DC, Reis LDO, Fontenele RC, Miranda-Viana M, Farias-Gomes A, Freitas DQ. Influence of an adjacent zirconium implant, tube current, and metal artifact reduction algorithm on horizontal root fracture diagnosis in cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol 2024;137:190-198. [PMID: 37940483 DOI: 10.1016/j.oooo.2023.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 09/21/2023] [Accepted: 10/01/2023] [Indexed: 11/10/2023]
5
Liu X, Lv H, Chen M, Chen S, Jia K, Quni S, Zhang L, Zhou Y. Case report and literature review: autonomous robotic system assisted palatal implantation at an anterior teeth site compromised by periapical cyst. Front Med (Lausanne) 2024;11:1335043. [PMID: 38288274 PMCID: PMC10822917 DOI: 10.3389/fmed.2024.1335043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 01/02/2024] [Indexed: 01/31/2024]  Open
6
Kuusisto N, Abushahba F, Syrjänen S, Huumonen S, Vallittu P, Närhi T. Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study. Dentomaxillofac Radiol 2023;52:20230252. [PMID: 37641961 DOI: 10.1259/dmfr.20230252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/31/2023]  Open
7
Cascante-Sequeira D, Fontenele RC, Martins LAC, Brasil DM, Oliveira ML, Freitas DQ, Haiter-Neto F. Does the shape of the field-of-view influence the magnitude of artefacts from high-density materials in cone-beam computed tomography? Dentomaxillofac Radiol 2023;52:20230147. [PMID: 37493606 PMCID: PMC10552126 DOI: 10.1259/dmfr.20230147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 06/12/2023] [Accepted: 06/14/2023] [Indexed: 07/27/2023]  Open
8
Orhan K, Kocyigit D, Firincioglulari M, Adisen MZ, Kocyigit S. Quantitative assessment of image artifacts from zygoma implants on CBCT scans using different exposure parameters. Proc Inst Mech Eng H 2023;237:1082-1090. [PMID: 37528643 DOI: 10.1177/09544119231190447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/03/2023]
9
Nomier AS, Gaweesh YSED, Taalab MR, El Sadat SA. Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study. BMC Oral Health 2022;22:615. [PMID: 36528573 PMCID: PMC9759909 DOI: 10.1186/s12903-022-02663-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022]  Open
10
Effect of the Field of View Size on CBCT Artifacts Caused by the Presence of Metal Objects in the Exomass. Int J Dent 2022;2022:2071108. [PMID: 36117513 PMCID: PMC9481401 DOI: 10.1155/2022/2071108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 08/08/2022] [Accepted: 08/26/2022] [Indexed: 11/29/2022]  Open
11
Moshfeghi M, Safi Y, Różyło-Kalinowska I, Gandomi S. Does the size of an object containing dental implant affect the expression of artifacts in cone beam computed tomography imaging? Head Face Med 2022;18:20. [PMID: 35765076 PMCID: PMC9241278 DOI: 10.1186/s13005-022-00326-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 06/13/2022] [Indexed: 11/29/2022]  Open
12
Sawicki P, Zawadzki PJ, Regulski P. The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review. Cureus 2022;14:e23035. [PMID: 35419219 PMCID: PMC8994570 DOI: 10.7759/cureus.23035] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/10/2022] [Indexed: 01/09/2023]  Open
13
Farias-Gomes A, Fontenele RC, Rosado LPL, Neves FS, Freitas DQ. The metal post material influences the performance of artefact reduction algorithms in CBCT images. Braz Dent J 2022;33:31-40. [DOI: 10.1590/0103-6440202204222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 05/08/2021] [Indexed: 11/22/2022]  Open
14
Bagis N, Kurt MH, Evli C, Camgoz M, Atakan C, Peker Ozturk H, Orhan K. Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study. Oral Radiol 2021;38:325-335. [PMID: 34387842 DOI: 10.1007/s11282-021-00561-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 08/03/2021] [Indexed: 11/30/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA