1
|
Goda B, Hamdi K, Eltoukhy RI, Ali AI, Mahmoud SH. Clinical performance of different bulk-fill composite resin systems in class II cavities: A 2-year randomized clinical trial. J ESTHET RESTOR DENT 2024; 36:1122-1137. [PMID: 38400614 DOI: 10.1111/jerd.13212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 01/04/2024] [Accepted: 02/10/2024] [Indexed: 02/25/2024]
Abstract
OBJECTIVES This study evaluated the clinical performance of bulk-fill resin composite systems with different viscosities in class II cavities. MATERIALS AND METHODS A total of 80 class II restorations were performed with a single operator in 50 patients using four different bulk-fill resin composite materials: Filtek™ Bulk Fill, Heated Filtek™ Bulk Fill, G-ænial™ BULK Injectable, and SonicFill3. A double-blinded randomized clinical trial was designed to evaluate the two-year clinical performance of the four bulk-fill composite resins using modified FDI criteria. Data were analyzed descriptively. Level of significance was set at 0.05. Differences between groups were tested using Wilcoxon-signed-rank and Mann-Whitney-U test as nonparametric tests. RESULTS Data were analyzed using Kruskal-Wallis, Mann-Whitney U, and Wilcoxon signed rank tests (p < 0.05). Eighty restorations were available for evaluation, with a survival function of 100%. No statistically significant differences were observed between the four groups regarding assessing esthetic, functional, and biological properties during different follow-up periods. CONCLUSIONS After 2 years of clinical follow-up, the bulk-fill composite systems with different viscosities seem to be esthetically, functionally, and biologically acceptable, with a promising clinical performance in class II cavities.
Collapse
Affiliation(s)
- Badria Goda
- Operative Department, Faculty of Dentistry, Horus University, New Damietta, Egypt
| | - Kareem Hamdi
- Operative Dentistry Department, Faculty of Dentistry, Zagazig University, Zagazig, Egypt
- Faculty of Dentistry, New Mansoura University, New Mansoura, Egypt, Egypt
| | - Radwa I Eltoukhy
- Operative Department, Faculty of Dentistry, Horus University, New Damietta, Egypt
- Operative Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Ashraf I Ali
- Operative Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Salah Hasab Mahmoud
- Operative Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
2
|
Aboelnor MM, Kamel MA. Cavity preparation and cementation of indirect adhesive posterior restorations using three different composite resins with a one-year follow-up: A clinical report. J Prosthet Dent 2024:S0022-3913(24)00462-1. [PMID: 39084922 DOI: 10.1016/j.prosdent.2024.06.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 06/01/2024] [Accepted: 06/04/2024] [Indexed: 08/02/2024]
Abstract
Adhesive cementation of contemporary indirect restorations can be achieved using a composite resin. An established protocol with preheated composite resin was used, along with 2 recently introduced types of composite resin. All 3 are evaluated for clinical performance.
Collapse
Affiliation(s)
- Menna Moataz Aboelnor
- Master's student, Department of Operative Dentistry, Faculty of Dentistry, Ain Shams University, Cairo, Egypt; and Teaching Assistant, Department of Conservative Dentistry, School of Dentistry, New Giza University, Giza, Egypt.
| | - Mohamed Amr Kamel
- Associate Professor, Department of Operative Dentistry, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| |
Collapse
|
3
|
Bueno T, Masoud N, Akkus A, Silva I, McPherson K, Furuse AY, Rizzante F. Effects of pre-heating on physical-mechanical-chemical properties of contemporary resin composites. Odontology 2024:10.1007/s10266-024-00953-x. [PMID: 38797796 DOI: 10.1007/s10266-024-00953-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 05/09/2024] [Indexed: 05/29/2024]
Abstract
This research assessed the effects of pre-heating on the physical-mechanical-chemical properties of different resin composites. For this, resin composites were evaluated in 6 levels: Admira/ADM, Vitra/VIT, Filtek Supreme/FS, Filtek Supreme Flowable/FSF, Filtek One/FO, and Filtek Bulk Fill Flowable/FBF; temperature was evaluated in 4 levels using a composite heater: room temperature/22 ºC, 37 ºC, 54 ºC, and 68 ºC. Response variables were: degree of conversion/DC, flexural strength/FS and color stability/ΔE (immediately after light curing/LC, after 7 days of dark-dry-storage, and after 24 h and 3 days of artificial aging in water at 60 ºC). Data were subjected to 2-way ANOVA (DC and FR) and 3-way repeated measurements ANOVA (ΔE), all followed by Tukey's test (α = 5%). DC were similar (FBF, FS, and FSF) or increased (ADM, FO, and VIT) as the temperature increased. Results of FR were unchanged or increased for all composites except VIT and ADM. High-viscosity composites (VIT and FS) showed higher FR values than low-viscosity composite (FSF). For bulk-fill composites, FBF and FO showed similar results, but lower than high-viscosity composites. Results of color stability showed acceptable values up to 3 days aging except for ADM and FSF. ΔE was not influenced by pre-heating and, overall, ΔE: FS < VIT < FO < FSF < ADM < FBF. Only VIT and FS showed ΔE ≤ 3.3 (clinical threshold). Therefore, the effects of pre-heating depend on the material. The tested materials generally showed similar or enhanced properties after pre-heating (except ADM and VIT).
Collapse
Affiliation(s)
| | - Nivien Masoud
- Department of Comprehensive Care, School of Dental Medicine, Case Western Reserve University, Cleveland, OH, USA
| | - Anna Akkus
- Lubrizol Advanced Materials, Inc, Brecksville, OH, USA
| | - Italo Silva
- Department of Macromolecular Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Karen McPherson
- Department of Reconstructive and Rehabilitation Sciences, James B. Edwards College of Dental Medicine, Department of Oral Rehabilitation, Medical University of South Carolina, 173 Ashley Ave, BSB 550E, Charleston, SC, 29425, USA
| | - Adilson Yoshio Furuse
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - Fabio Rizzante
- Department of Reconstructive and Rehabilitation Sciences, James B. Edwards College of Dental Medicine, Department of Oral Rehabilitation, Medical University of South Carolina, 173 Ashley Ave, BSB 550E, Charleston, SC, 29425, USA.
| |
Collapse
|
4
|
Nezir M, Özcan S. In Vitro Evaluation of Mechanical, Surface, and Optical Properties of Restorative Materials Applied with Different Techniques. J Funct Biomater 2024; 15:128. [PMID: 38786640 PMCID: PMC11122343 DOI: 10.3390/jfb15050128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 05/09/2024] [Accepted: 05/13/2024] [Indexed: 05/25/2024] Open
Abstract
(1) Background: currently, the advantages of bulk-fill resin composite and high-viscosity glass ionomer materials have increased their use in dentistry; accordingly, their mechanical, surface, and optical properties have become more important. This study aimed to evaluate the mechanical, surface, and optical properties of three different restorative materials (a high-viscosity bulk-fill resin composite (TNC), a flowable bulk-fill resin composite (EBF), and a high-viscosity glass ionomer (FIX)) after application using different techniques (control, heat application, and ultrasonic activation). (2) Methods: specimens were prepared to assess the color stability and surface roughness (n = 12). The specimens were immersed in two different solutions for 14 days. For the compressive strength test, specimens were prepared using a Teflon mold (n = 12). (3) Results: among the specimens applied according to the manufacturer's instructions and immersed in distilled water, it was observed that the surface roughness values of FIX on the 7th day were statistically significantly higher than the other materials (p < 0.05). The compressive strength values of EBF applied using ultrasonic activation were significantly lower than those of EBF applied using the other techniques (p < 0.05). (4) Conclusions: coffee can negatively affect the color stability of restorative materials, but discoloration may vary depending on differences in the content of the material. All materials evaluated in this study exhibited clinically acceptable surface roughness values. It can be concluded that flowable bulk-fill resin composite is the most durable material in terms of compressive strength, so it can be used in the restoration of posterior teeth, especially those exposed to intensive stress.
Collapse
Affiliation(s)
- Merve Nezir
- Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, 06490 Ankara, Turkey;
| | | |
Collapse
|
5
|
Elkady M, Abdelhakim S, Riad M. The clinical performance of dental resin composite repeatedly preheated: A randomized controlled clinical trial. J Dent 2024; 144:104940. [PMID: 38490324 DOI: 10.1016/j.jdent.2024.104940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/22/2024] [Accepted: 03/12/2024] [Indexed: 03/17/2024] Open
Abstract
OBJECTIVES To assess the clinical performance of class II restorations performed by repeatedly preheated resin composite "RC" at 68 °C up to ten times. METHODS 105 patients were selected and randomized into three groups, each comprising 35 patients. Each patient was provided with a single class II Bulk-fill resin composite "BF-RC" posterior restoration based on the number of preheating cycles; group I (H0): The BF-RC was packed non-heated, group II (H1): BF-RC preheated once, and group III(H10): BF-RC preheated ten cycles. These restorations were evaluated at 1, 3,6, and 12 months, using the modified United States Public Health Service "USPHS". Statistical analysis was performed using Kruskal-Wallis test, Mann Whitney U test, and Friedmann test, where p = 0.05. RESULTS All the 105 restorations did not suffer from any clinical situation that recommended replacement regarding retention, fracture, secondary caries, or anatomical form. Although all performed restorations did have Alpha and Bravo scores with good clinical performance, the non-preheated RC restorations"" suffered from relatively inferior clinical performance through the follow-up period regarding marginal adaptation, marginal discoloration, and color matching when compared to preheated groups. One and ten times of preheating conducted better clinical performance. CONCLUSIONS After 12-months follow-up, although no restoration needed replacement or repair in the 3 tested groups, restorations with single and ten times of preheating aided in better clinical performance of RC restorations compared to the non-preheated restorations. Preheating of RC for 10 times could be used safely with good clinical performance of restorations. CLINICAL SIGNIFICANCE By continually preheating RC syringe up to ten times, the dentist will not only benefit from the enhanced clinical performance and easiness of application but also will use preheated RC syringes without hesitation, relying on the absence of drawbacks related to multiple preheating cycles.
Collapse
Affiliation(s)
- Mahmoud Elkady
- Conservative Dentistry Department, Faculty of Dentistry, Assiut University, Egypt
| | - Safaa Abdelhakim
- Operative Dentistry Department, Faculty of Dentistry, Minia University, Egypt
| | - Mona Riad
- Conservative Dentistry Department, Faculty of Dentistry, 11 El-Saraya St, Cairo UniversityManial, Cairo 11553, Egypt.
| |
Collapse
|
6
|
Favoreto MW, Carneiro TDS, Ñaupari-Villasante R, Cordeiro DC, Cochinski GD, Machado do Nascimento TVP, Matos TDP, Bandeca MC, Reis A, Loguercio AD. Clinical performance of preheating thermoviscous composite resin for non-carious cervical lesions restoration: A 24-month randomized clinical trial. J Dent 2024; 144:104930. [PMID: 38471581 DOI: 10.1016/j.jdent.2024.104930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 02/17/2024] [Accepted: 03/05/2024] [Indexed: 03/14/2024] Open
Abstract
OBJECTIVES This 24-month, double-blind, split-mouth randomized clinical trial aimed to compare the retention rates of a preheated thermoviscous composite resin (PHT) compared to a non-heated composite resin (NHT) in non-carious cervical lesions (NCCLs). METHODS A total of 120 restorations were restored on NCCLs using a preheated (VisCalor bulk, Voco GmbH) and a non-heated (Admira Fusion, Voco GmbH) composite resins with 60 restorations per group. A universal adhesive in the selective enamel conditioning was applied. In the PHT group, composite was heated at 68 °C for using a bench heater. In the NHT group, no heating was employed. Both restorative materials were dispensed into caps and inserted into the NCCLs. The restorations were evaluated at baseline, 6, 12, 18, and after 24 months of clinical service using the FDI criteria. Statistical analysis was performed with Kaplan-Meier estimation analysis for retention/fracture rate and Chi-square test for the other FDI parameters (α=0.05). RESULTS After 24 months 108 restorations were assessed. Seven restorations were lost (two for PHT group and five for NHT group), and the retention rates (95 % confidence interval [CI]) were 96.7 % (81.5-99.9) for PHT group and 90.8 % (81.1-96.0) for NHT group, with no statistical differences between them (p > 0.05). The hazard ratio (95 % CI) was 0.52 (0.27 to 1.01), with no significant difference within groups. In terms of all other FDI parameters that were assessed, all restorations were deemed clinically acceptable. CONCLUSIONS Both composites showed high rates of retention rates after 24 months. CLINICAL SIGNIFICANCE The clinical performance of the new preheated thermoviscous was found to be as good as the non-heated composite after 24-month of clinical evaluation in non-carious cervical lesions. REGISTRATION OF CLINICAL TRIALS RBR-6d6gxxz.
Collapse
Affiliation(s)
- Michael Willian Favoreto
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil; School of Dentistry, Tuiuti University, Curitiba, Paraná, Brazil
| | - Taynara de Souza Carneiro
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil; Department of Stomatology, IDIBO research group, Health Sciences Faculty, Rey Juan Carlos University, Alcorcón, Madrid, Spain
| | - Romina Ñaupari-Villasante
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
| | - Deisy Cristina Cordeiro
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
| | - Gabriel David Cochinski
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
| | | | | | - Matheus Coelho Bandeca
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil
| | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil.
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, Paraná, Brazil.
| |
Collapse
|
7
|
Elkady M, Abdelhakim SH, Riad M. Impact of repeated preheating of bulk-fill resin composite on postoperative hypersensitivity; a randomized controlled clinical trial. BMC Oral Health 2024; 24:453. [PMID: 38622629 PMCID: PMC11017642 DOI: 10.1186/s12903-024-04170-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 03/20/2024] [Indexed: 04/17/2024] Open
Abstract
BACKGROUND This clinical study was conducted aiming to evaluate the impact of repeated preheating of bulk-fill resin composite on postoperative hypersensitivity. METHODS A total of 105 eligible, consenting adults were recruited. Patients had posterior teeth suffering from proximal decay with no signs of irreversible pulpitis. Patients were prepared for Class II restorations and restored with bulk-fill resin composite. Patients were randomized into three groups of 35 patients according to the number of preheating cycles for the resin composite syringe used; group I: no preheating; control group at room temperature, group II: Resin composite preheated once, and group III: Resin composite preheated ten cycles. Patients were assessed for postoperative dentin hypersensitivity using the visual analogue scale (VAS) at three-time intervals: day one, one week and by the end of one month after restorative treatment. Statistical analysis was performed; ANOVA with a single factor was used to test for significance at a p value ≤ 0.05. For nonparametric data, the Kruskal‒Wallis test was used to compare the three testing groups. Friedman's test was used to study the changes within each group. Dunn's test was used for pairwise comparisons when the Kruskal‒Wallis test or Friedman's test was significant. RESULTS The scores of the three groups through the three time intervals were almost zero except for the first day where VAS scores were recorded with maximum score of 3 for groups I and II. Groups II and III; there was no statistically significant change in hypersensitivity scores by time with P-values 0.135 and 0.368, respectively. However, for group I there was a significant difference from VAS score recorded on first day and the two following time intervals. CONCLUSION The repeated preheating cycles of bulk-fill resin composite prior to curing had no adverse effect on the patients regarding postoperative dentin hypersensitivity. This information could be of utmost significance, as the same resin composite syringe can undergo numerous preheating cycles clinically before it is completely consumed with the advantage of improvement on the handling properties. TRIAL REGISTRATION The protocol of the current study was registered at www. CLINICALTRIALS gov , with the identification number NCT05289479 on 21/03/2022. All procedures involving human participants were performed in accordance with the ethical standards of the Research Ethics Committee of the Faculty of Dentistry, Minia University, Egypt, under the approval number 73/440 on 11/09/2020.
Collapse
Affiliation(s)
- Mahmoud Elkady
- Conservative Dentistry Department, Faculty of Dentistry, Assiut University, Assiut, Egypt
| | | | - Mona Riad
- Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt.
| |
Collapse
|
8
|
Poubel DLDN, da Silva RC, Ribeiro APD, Garcia FCP. Effect of preheating on the viscosity of composite resins. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:360-365. [PMID: 38779215 PMCID: PMC11108411 DOI: 10.4103/jcde.jcde_75_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 02/20/2024] [Accepted: 03/26/2024] [Indexed: 05/25/2024]
Abstract
Aim To determine the effects of time and temperature on the viscosity of preheated composite resins. Materials and Methods Eleven composite resins were heated to 60°C, and temperature analyses were performed at intervals of 1 min until they had cooled to 25°C. The permanent oscillatory shear test was performed at 25°C, 35°C, 50°C, and 60°C for three composite resins under a shear rate of 1s-1. One- and two-way analysis of variance were used for the analysis (α = 0.05). Results There was no significant interaction between the composite resin and time (P = 0.9304), and only the main effect time was significantly different (P < 0.0001). A difference was observed between T0 and T6 (P < 0.001), but not after T7. The increase in temperature resulted in a viscosity reduction (P < 0.05). At 25°C, Beautifil II presented higher viscosity. Palfique LX5 showed a significant viscosity reduction with increasing temperature compared with the others (P < 0.05). For Beautifil II and Z100, there was no difference at temperatures of 50°C and 60°C, while for Palfique LX5, no statistical difference was observed at 35°C, 50°C, and 60°C. Conclusions Ten minutes of preheating were sufficient to reach a temperature of 60°C, reducing viscosity by at least 84%. However, 5 min after removal, the composite resin cooled to room temperature. Clinical Significance Preheating composite resin has potential benefits. To determine how this approach will work in clinical practice, it is important to define the effects of time and temperature in the protocol of this technique and understand its limitations.
Collapse
|
9
|
Souza TJSD, Freitas ADS, Ferreira DMTP, Maia LC, Rabello TB. Does the use of preheated restorative resin composite as a luting agent influence the adaptation of fixed dental prostheses? A systematic review. J Prosthet Dent 2024; 131:384-391. [PMID: 35300849 DOI: 10.1016/j.prosdent.2022.02.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 02/03/2022] [Accepted: 02/04/2022] [Indexed: 11/18/2022]
Abstract
STATEMENT OF PROBLEM Although studies have explored the physical and mechanical properties of different composite resins with the preheating technique, evidence that the use of preheated restorative composite resin as a luting agent influences the adaptation of fixed dental prostheses is lacking. PURPOSE The purpose of this systematic review was to answer the question: Does the use of preheated restorative composite resin as a luting agent influence the adaptation of fixed dental prostheses? MATERIAL AND METHODS Seven databases and nonpeer-reviewed literature were searched, without language or year restrictions. Studies directly comparing the adaptation of fixed dental prostheses cemented with preheated restorative composite resin or resin cement were considered eligible for inclusion. Assessment of the risk of bias was based on a 9-item checklist. RESULTS Of 2109 retrieved articles, 4 in vitro studies met the inclusion criteria. Three of them concluded that preheated restorative composite resin produced a greater mismatch than resin cement, and the remaining study reported that composite resin improved the adaptation of fixed dental prostheses. All included studies had a medium risk of bias. The high level of heterogeneity among the studies precluded meta-analysis. CONCLUSIONS The use of preheated restorative composite resin as a luting agent seems to negatively influence the adaptation of fixed dental prostheses. It was not possible to evaluate whether variables such as the formulation of the resin material or its heating time and temperature influence the adaptation of fixed dental prostheses because of the high heterogeneity of the included studies.
Collapse
Affiliation(s)
- Talita Jardim Serra de Souza
- Masters student in Operative Dentistry, Department of Dental Clinic, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil
| | - Alessandra da Silva Freitas
- Masters student in Operative Dentistry, Department of Dental Clinic, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil
| | - Daniele Masterson Tavares Pereira Ferreira
- Doctoral student, Health Information and Communication, Institute of Communication and Scientific Information and Technological in Health, Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro, RJ, Brazil
| | - Lucianne Cople Maia
- Full Professor, Department of Pediatric Dentistry and Orthodontics, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil
| | - Tiago Braga Rabello
- Associate Professor, Department of Dental Clinic, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil.
| |
Collapse
|
10
|
Alshabib A, AlDosary K, Algamaiah H. A comprehensive review of resin luting agents: Bonding mechanisms and polymerisation reactions. Saudi Dent J 2024; 36:234-239. [PMID: 38420009 PMCID: PMC10897588 DOI: 10.1016/j.sdentj.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/06/2023] [Accepted: 11/07/2023] [Indexed: 03/02/2024] Open
Abstract
The field of dentistry is constantly evolving and increasingly embracing minimally invasive approaches. One such approach, which is bonding to the tooth structure, particularly enamel, has been shown to offer the most predictable outcomes. However, there are instances where significant tooth loss may limit treatment options for a restorative dentist. In these scenarios, indirect restoration might be the preferred treatment option. This literature review provides a comprehensive examination of the currently available resin luting agents and their bonding requirements. It provides valuable insights for dental professionals seeking an in-depth understanding of the current state of the field and the future prospects of dental adhesion.
Collapse
Affiliation(s)
- Abdulrahman Alshabib
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Khalid AlDosary
- Dental Department, King Abdulaziz University Hospital, King Saud University, Riyadh, Saudi Arabia
| | - Hamad Algamaiah
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
11
|
Atasoy S, Akarsu S. Effect of repeated preheating on monomer elution from a bulk-fill composite resin. J Dent Res Dent Clin Dent Prospects 2023; 17:265-270. [PMID: 38585001 PMCID: PMC10998168 DOI: 10.34172/joddd.2023.40780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 12/01/2023] [Indexed: 04/09/2024] Open
Abstract
Background Due to incomplete polymerization of composite resin restorations, residual monomers adversely affect their mechanical properties and biocompatibility. Preheating of composite resins is advised to increase the degree of conversion and reduce monomer elution. This study aimed to analyze the effect of preheating and repeated preheating on the amount of monomer released from a bulk-fill composite resin. Methods Forty samples were prepared using Filtek One Bulk Fill Restorative composite resin. Samples in one group were fabricated at room temperature, whereas the composite resins in the other groups were cured after 1, 10, or 20 repeated preheating cycles (55 °C), 10 in each group. Eluted urethane dimethacrylate (UDMA) and bisphenol-A-glycidylmethacrylate (BisGMA) monomers were measured with high-performance liquid chromatography (HPLC) 24 hours and 30 days after immersion. The data were evaluated using one-way ANOVA and post hoc Tukey tests. Paired-sample t tests were used to test the differences between time intervals. Results At both time intervals, the greatest amounts of released BisGMA, UDMA, and total monomers were obtained from the control group, whereas 10 preheating cycles resulted in the least monomer elution. The decrease in monomer elution was not statistically significant after 10 preheating cycles compared with that after one preheating cycle (P>0.05). The group with 20 preheating cycles showed a greater amount of monomer elution compared to that with 1 and 10 cycles, which was statistically significant (P < 0.05). The amount of released monomers on day 30 was significantly higher than on day 1 (P<0.01). Conclusion Preheating of the bulk-fill composite resin was shown to be effective in reducing monomer elution. However, monomer elution was adversely affected after repeated preheating cycles of 20.
Collapse
Affiliation(s)
- Samet Atasoy
- Department of Restorative Dentistry, Faculty of Dentistry, Ordu University, Ordu, Turkey
| | | |
Collapse
|
12
|
Marins LDAV, Araújo-Neto VG, Sahadi BO, André CB, Giannini M. Toothbrushing effects on the surface roughness and cement volume loss of bonded enamel-ceramic interface. Braz Dent J 2023; 34:63-71. [PMID: 38133474 PMCID: PMC10759952 DOI: 10.1590/0103-6440202305459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 10/21/2023] [Indexed: 12/23/2023] Open
Abstract
This study evaluated the effect of toothbrushing on enamel-cementing material-ceramic bonded interfaces, using different cementing materials. MATERIALS AND METHODS Thirty enamel and thirty ceramic blocks were bonded with cementing materials to produce the samples that were bonded with three types of cementing materials: 1- RelyX Ultimate resin cement (REXU), 2- RelyX Unicem 2 self-adhesive resin cement (REU2) and 3- heated Z100 restorative composite (60°C). Bonded interfaces of the samples were toothbrushed and the surfaces of the 3 cementing materials were evaluated for roughness (RG, in µm), roughness profile (RP, in µm), and volume loss (VL, in µm3) (baseline and after 20,000 and 60,000 toothbrushing cycles). Data were evaluated by Generalized Linear Analysis (two factors: "material" and "toothbrushing cycle") and Bonferroni test (α=0.05). RESULTS REXU and Z100 exhibited lower RG than that presented by REU2, except after 60,000 toothbrushing cycles when only Z100 differed from REU2. The increase in toothbrushing cycles increased the RG and RP for all materials. REU2 also showed higher RP than those showed by REXU and Z100 when it was analyzed regarding the enamel. The VL of Z100 was the lowest with 20,000 toothbrushing cycles, regarding the enamel and ceramic. For 60,000 cycles, REXU showed the lowest VL regarding the ceramic, and REU2 had the highest VL regarding the enamel and ceramic. CONCLUSION In general, REXU and Z100 showed the best results regarding the evaluations performed and the REU2 exhibited the highest RG, RP, and VL.
Collapse
Affiliation(s)
| | - Vitaliano Gomes Araújo-Neto
- Dental Materials Division, Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas; Piracicaba, SP, Brazil
| | - Beatriz Ometto Sahadi
- Operative Dentistry Division, Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas; Piracicaba, SP, Brazil
| | - Carolina Bosso André
- Operative Dentistry Division, Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais; Belo Horizonte, MG, Brazil
| | - Marcelo Giannini
- Operative Dentistry Division, Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas; Piracicaba, SP, Brazil
| |
Collapse
|
13
|
Josic U, D'Alessandro C, Miletic V, Maravic T, Mazzitelli C, Jacimovic J, Sorrentino R, Zarone F, Mancuso E, Delgado AH, Breschi L, Mazzoni A. Clinical longevity of direct and indirect posterior resin composite restorations: An updated systematic review and meta-analysis. Dent Mater 2023; 39:1085-1094. [PMID: 37827872 DOI: 10.1016/j.dental.2023.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 09/21/2023] [Accepted: 10/05/2023] [Indexed: 10/14/2023]
Abstract
OBJECTIVES To answer the PICO(S) question: Is there a difference in clinical longevity between direct and indirect resin composite restorations placed on permanent posterior teeth? DATA Randomized controlled clinical trials (RCTs) investigating direct and indirect resin composite restorations in posterior permanent teeth were considered. SOURCES Several electronic databases were searched, with no language or date restrictions. The revised Cochrane Collaboration's tool for assessing risk of bias (RoB-2) was used to analyze the studies; meta-analyses were run and the certainty of evidence was assessed by the GRADE tool. A subgroup meta-analysis was performed for resin composite restorations placed on posterior worn dentition. STUDY SELECTION Twenty-three articles were included in qualitative synthesis, while 8 studies were used for meta-analyses. According to the RoB-2 tool, 5 studies were ranked as "low risk", 7 had "some concerns", while 11 papers were rated as "high risk" of bias. There were no statistically significant differences in short-term (p = 0.27; RR=1.54, 95% CI [0.72, 3.33]), medium-term (p = 0.27; RR=1.87, 95% CI [0.61, 5.72]) and long-term longevity (p = 0.86; RR=0.95, 95% CI [0.57, 1.59]). The choice of restorative technique had no influence on short-term survival of resin composite restorations placed on worn dentition (p = 0.13; RR=0.46, 95% CI [0.17, 1.25]). The certainty of evidence was rated as "very low". CONCLUSIONS Direct and indirect resin composite restorations may show similar clinical longevity in posterior region, regardless of the observation period or substrate (wear-affected and non-affected dentition). The very low quality of evidence suggests that more long-term RCTs are needed to confirm our results.
Collapse
Affiliation(s)
- Uros Josic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Carlo D'Alessandro
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Vesna Miletic
- Sydney Dental School, Faculty of Medicine and Health, University of Sydney, Sydney 2145, Australia
| | - Tatjana Maravic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Claudia Mazzitelli
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Jelena Jacimovic
- Central Library, School of Dental Medicine, University of Belgrade, Serbia
| | - Roberto Sorrentino
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Italy
| | - Fernando Zarone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Italy
| | - Edoardo Mancuso
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - António Hs Delgado
- Egas Moniz Center for Interdisciplinary Research (CiiEM), Monte de Caparica, Almada 2829-511, Portugal; Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, London, UK
| | - Lorenzo Breschi
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy.
| | - Annalisa Mazzoni
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| |
Collapse
|
14
|
Liberato WF, Silikas N, Watts DC, Cavalcante LM, Schneider LFJ. Luting laminate veneers: Do resin-composites produce less polymerization stress than resin cements? Dent Mater 2023; 39:1190-1201. [PMID: 37858420 DOI: 10.1016/j.dental.2023.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/27/2023] [Accepted: 09/27/2023] [Indexed: 10/21/2023]
Abstract
OBJECTIVES Regular composites could produce less polymerization stress than resin cements when luting laminate veneers but there is no proper evidence to support this theory. The current study aimed to determine the degree of conversion, volumetric shrinkage, polymerization stress and the resultant elastic moduli of materials currently used for adhesive cementation and to determine possible correlations. METHODS The study considered (i) regular resin composites (Admira Fusion, Gradia, Grandioso, Palfique, Sirius Z, Viscalor and Z100) at room and pre-warmed (PW) at 69ºC, (ii) flowable composites (Sigma Flow and Grandioso Flow); (iii) solely light-activated cements (AllCem Veneer, Variolink Esthetic and RelyX Veneer); and (iv) one dual-activated resin cement (SpeedCEM). Degree of conversion (DC, n = 3) was accessed with FTIR 1 h after irradiation. Bonded-disk and Bioman II instruments were used to access polymerization shrinkage strain and shrinkage stress, respectively, for 60 min at 23 ± 1◦C (n = 3). The elastic modulus was determined by 3-point bending flexural test (n = 6). The results were submitted to analyse s of variance, Tukey's, and correlation tests. RESULTS For regular composites, the pre-warming did not affect DC, shrinkage and modulus but significantly increased the stress magnitude. Correlation tests indicated a significant relationship only between stress and polymerization shrinkage (r = 0.811343). SIGNIFICANCE Regular composites can produce less polymerization stress than resin cements when luting laminate veneers. Polymerization stress was dependent on the shrinkage magnitude, but not on the degree of conversion nor the elastic modulus.
Collapse
Affiliation(s)
- Walleska Feijó Liberato
- School of Dentistry, Federal Fluminense University, Niteroi, Rio de Janeiro, Brazil; Biomaterials Research Group, School of Medical Sciences, Division of Dentistry, The University of Manchester, Manchester, United Kingdom; Nucleus for Dental Biomaterials Research, Veiga de Almeida University, Rio de Janeiro, Brazil
| | - Nikolaos Silikas
- Biomaterials Research Group, School of Medical Sciences, Division of Dentistry, The University of Manchester, Manchester, United Kingdom
| | - David C Watts
- Biomaterials Research Group, School of Medical Sciences, Division of Dentistry, The University of Manchester, Manchester, United Kingdom
| | | | - Luis Felipe J Schneider
- School of Dentistry, Federal Fluminense University, Niteroi, Rio de Janeiro, Brazil; Nucleus for Dental Biomaterials Research, Veiga de Almeida University, Rio de Janeiro, Brazil.
| |
Collapse
|
15
|
Boruziniat A, Khosravi F, Shahri A, Saeedi M. Effect of preheating nano-hybrid and bulk-fill composites with warm airstream on their microtensile bond strength to dentin. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2023; 26:702-708. [PMID: 38292739 PMCID: PMC10823972 DOI: 10.4103/jcde.jcde_123_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 09/28/2023] [Accepted: 10/01/2023] [Indexed: 02/01/2024]
Abstract
Aims This study assessed the effect of preheating nano-hybrid and bulk-fill composites with warm airstream on their microtensile bond strength (MTBS) to dentin. Materials and Methods In this in vitro study, dentin was exposed in 42 extracted premolars that were assigned to two groups (n = 21) for bonding to EverX Posterior bulk-fill and Grandio nano-hybrid posterior composite. Each group was subdivided into three subgroups for preheating of composite to 50°C by a commercial composite warmer (Subgroup 1), a warm airstream by a hair dryer for 10 s (Subgroup 2), and no heating (room temperature; Subgroup 3). Composite cylinders with a 4-mm height were bonded to the tooth surface with a 5th-generation bonding agent using the incremental technique and cured (each increment for 30 s). The MTBS to dentin was measured, and the bonding interface was evaluated under a stereomicroscope and a scanning electron microscope (SEM). Data were analyzed using one-way and two-way ANOVA, Tukey's test, and independent t-test (α =0.05). Results In both composite groups, the mean MTBS of the warm airstream subgroup was significantly higher than that of warmer (P < 0.001) and control (P < 0.001) subgroups. The mean MTBS of the warmer subgroup was significantly lower than that of control subgroup (P = 0.01). The MTBS of the EverX composite was significantly higher than that of the Grandio composite only in the warmer group (P < 0.05). Adhesive failure occurred more frequently in all groups with the highest frequency in airstream subgroup of both composite types. Conclusion Preheating with a warm airstream significantly increased the MTBS of both composite types to dentin.
Collapse
Affiliation(s)
| | - Farzaneh Khosravi
- Department of Restorative Dentistry, School of Dentistry, Mashhad, Iran
| | | | - Mahdi Saeedi
- Department of Oral and Maxillofacial Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
16
|
Favoreto MW, de Souza Carneiro T, Wendlinger M, Ñaupari-Villasante R, de Matos TP, Kunz PM, Reis A, Loguercio AD. Various ways of pre-heating a bulk-fill thermoviscous composite in restoration in non-carious cervical lesions: 12-month randomized clinical trial. Clin Oral Investig 2023; 27:4345-4359. [PMID: 37217713 DOI: 10.1007/s00784-023-05054-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 04/30/2023] [Indexed: 05/24/2023]
Abstract
OBJECTIVE The objective of the study is to evaluate through a randomized clinical trial the best method to preheat a composite resin, if using a Caps dispenser device associated with Caps Warmer (CD) or with a VisCalor Caps dispenser/warmer (VD) for restorations in non-carious cervical lesions (NCCLs). MATERIAL AND METHODS One hundred and twenty restorations were distributed to two groups (n = 60) according to the pre-heating way of thermoviscous bulk-fill composite resin. For the CD group, pre-heating was carried at 68 °C using a heating bench for 3 min. For the VD group, pre-heating was performed at 68 °C using a heating gun for 30 s. After that, pre-heated bulk-fill composites were directly inserted in the NCCLs. The total working time was recorded. The restorations were evaluated after 6 and 12 months of clinical performance according to the FDI criteria. Statistical analysis was performed using the Student's t test for unpaired samples for working time, and the Chi-square test for restoration clinical performance (α = 0.05). RESULTS Working time was shorter for VD with a statistically significant difference compared to CD (p = 0.01). Few restorations were lost or fractured after 12 months of clinical evaluation (p > 0.05). The retention rates were 96.7% (CI 95 %: 88.6-99.1%) for CD and 98.3% (CI 95 %: 91.1-99.7%) for VD. The other FDI parameters were considered clinically acceptable. CONCLUSIONS The different pre-heating ways did not influence the clinical performance of thermoviscous bulk-fill composite restorations in NCCLs after 12 months. CLINICAL RELEVANCE Regardless of the bulk-fill thermoviscous composite resin pre-heating ways, the restorations are clinically acceptable after 12 months.
Collapse
Affiliation(s)
- Michael Willian Favoreto
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil
| | - Taynara de Souza Carneiro
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil
| | - Michel Wendlinger
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil
| | - Romina Ñaupari-Villasante
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil
| | | | - Patricia Manozzo Kunz
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil
- Department of Restorative Dentistry, Tuiuti University of Parana, Parana, Brazil
| | - Alessandra Reis
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil.
| |
Collapse
|
17
|
Mandurino M, Di Domenico GL, Baldani S, Collivasone G, Gherlone EF, Cantatore G, Paolone G. Dental Restorations. Bioengineering (Basel) 2023; 10:820. [PMID: 37508847 PMCID: PMC10376857 DOI: 10.3390/bioengineering10070820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 07/04/2023] [Indexed: 07/30/2023] Open
Abstract
Fulfilling a patient's request for a healthy, functional and esthetic smile represents a daily challenge for dental practitioners [...].
Collapse
Affiliation(s)
- Mauro Mandurino
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| | | | - Sofia Baldani
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| | - Giacomo Collivasone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| | | | - Giuseppe Cantatore
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| | - Gaetano Paolone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| |
Collapse
|
18
|
da Silva MVM, Batista JMN, Fraga MAA, Correr AB, de Campos EA, Geraldeli S, Sinhoreti MAC. Surface Analysis of a Universal Resin Composite and Effect of Preheating on its Physicochemical Properties. Braz Dent J 2023; 34:115-126. [PMID: 37909634 PMCID: PMC10642265 DOI: 10.1590/0103-6440202305411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 06/22/2023] [Indexed: 11/03/2023] Open
Abstract
This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS) and FS preheated (FSH). The film thickness (FT) test (n = 10) was done using two glass slabs under compression. Flexural strength (FLS) and modulus (FLM) were evaluated using a three-point flexion test (n = 10). Polymerization shrinkage stress (PSS) was evaluated in a universal testing machine (n = 5). Gap width (GW) between composite and mold was measured in internally polished metallic molds (n = 10). The degree of conversion (DC) was evaluated by Fourier Transform Infrared spectroscopy (n = 3). The morphology of the filler particles was checked by scanning electron microscope (SEM) and EDX analysis. Surface gloss (SG) and surface roughness (SR) were evaluated before and after mechanical brushing (n = 10). The outcomes were submitted to 2-way ANOVA and Tukey's test (α = 0.05). Lower mean values of FT were observed for the preheated groups when compared to the non-preheated groups. URH and FSH showed higher mean values of FLS and FLM when compared with UR and FS. No differences were observed between groups in the PSS test. The GW was higher for the UR and FS groups when compared with URH and FSH. The DC was higher for preheated resin composites when compared to the non-preheated groups. The SR of the UR composite was higher than the FS after mechanical brushing, while the SG was higher for the FS groups. In conclusion, the universal resin composite tested generally presented similar physicochemical properties compared with the nanofilled resin composite and either similar or slightly inferior surface properties. The preheating improved or maintained all properties evaluated.
Collapse
Affiliation(s)
- Marcus Vinícyus Manoel da Silva
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - João Marcos Nascimento Batista
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - May Anny Alves Fraga
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Américo Bortolazzo Correr
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Edson Alves de Campos
- Department of Restorative Dentistry, Araraquara Dental School, Sao Paulo State University, Araraquara, SP, Brazil
| | - Saulo Geraldeli
- Division of Biomedical Materials, School of Dental Medicine, East Carolina University, Greenville, NC, USA
| | - Mário Alexandre Coelho Sinhoreti
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
19
|
Bolding KH, Hill AE, Tantbirojn D, Versluis A. Prewarming effect on adaptation, porosities, and strength of a composite resin. J Mech Behav Biomed Mater 2023; 143:105913. [PMID: 37257311 DOI: 10.1016/j.jmbbm.2023.105913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/12/2023] [Accepted: 05/14/2023] [Indexed: 06/02/2023]
Abstract
Warming composite resin before insertion to reduce viscosity is advocated for improving adaptation and reducing voids. This study evaluated how prewarming altered porosities, adaptation, and strength. Twenty composite restorations were placed in 2 increments in typodont teeth with a large Class II preparation. The composite was either at room temperature (control) or prewarmed to 68 °C (n = 10/group). Each increment was light-cured for 20s. After 24h, the restored teeth were sectioned and imaged under a stereomicroscope. Examiners ranked the quality of adaptation to walls and between increments, and the presence of voids on a 0-3 scale. Results were statistically analyzed using Mann-Whitney U Test. Diametral tensile strength of monolithic or incrementally-filled composite cylinders (6 mm diameter × 4 mm height; n = 10/group) made with room temperature or prewarmed composite were tested at 0.5 mm/min. Strength results were analyzed using ANOVA statistics followed by pairwise comparisons. Restorations made with prewarmed composite had significantly fewer large voids and better adaptation to cavity walls and between layers (P < 0.05). Strength of prewarmed composite was higher than room temperature composite, and was significantly higher in monolithic specimens (P < 0.05). It was concluded that prewarming conventional composite can improve its handling, making it handle more like a flowable composite without jeopardizing physical properties. The prewarmed composite was found to have better adaptation and fewer voids, and attained higher strength than composite that was not prewarmed.
Collapse
Affiliation(s)
- K H Bolding
- College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
| | - A E Hill
- Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
| | - D Tantbirojn
- Department of General Dentistry, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
| | - A Versluis
- Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA.
| |
Collapse
|
20
|
Silva G, Marto CM, Amaro I, Coelho A, Sousa J, Ferreira MM, Francisco I, Vale F, Oliveiros B, Carrilho E, Paula AB. Bulk-Fill Resins versus Conventional Resins: An Umbrella Review. Polymers (Basel) 2023; 15:2613. [PMID: 37376259 DOI: 10.3390/polym15122613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 06/02/2023] [Accepted: 06/06/2023] [Indexed: 06/29/2023] Open
Abstract
Currently, composite resins have become the material of choice for the restoration of posterior teeth. Although bulk-fill resins represent a tempting alternative due to their lower complexity and faster use, some dentists are reluctant to use this material. The objective is to compare the performance of bulk-fill resins and conventional resins in direct restorations of posterior teeth based on the literature. The databases that were used to carry out the research were PubMed/MEDLINE, Embase, the Cochrane Library and the WOS. This umbrella literature review complies with PRISMA standards and assesses the quality of studies using the AMSTAR 2 tool. With the application of the criteria of the AMSTAR 2 tool, the reviews were considered low to moderate. The overall meta-analysis, although without statistical significance, favours mostly the use of conventional resin, as it is about five times more likely to obtain a favourable result than bulk-fill resin. Bulk-fill resins result in a simplification of the clinical process of posterior direct restorations, which is an advantage. The performance in terms of several properties of bulk-fill resins and conventional resins showed that they present similar behaviour.
Collapse
Affiliation(s)
- Gonçalo Silva
- Institute of Integrated Clinical Practice, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
| | - Carlos Miguel Marto
- Institute of Integrated Clinical Practice, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute of Experimental Pathology, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
| | - Inês Amaro
- Institute of Integrated Clinical Practice, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
| | - Ana Coelho
- Institute of Integrated Clinical Practice, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
| | - José Sousa
- Institute of Integrated Clinical Practice, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
| | - Manuel Marques Ferreira
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
- Institute of Endodontics, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
| | - Inês Francisco
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
- Institute of Orthodontics, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
| | - Francisco Vale
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
- Institute of Orthodontics, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
| | - Bárbara Oliveiros
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
- Laboratory of Biostatistics and Medical Informatics (LBIM), Faculty of Medicine, University of Coimbra, 3004-531 Coimbra, Portugal
| | - Eunice Carrilho
- Institute of Integrated Clinical Practice, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
| | - Anabela Baptista Paula
- Institute of Integrated Clinical Practice, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Laboratory for Evidence-Based Sciences and Precision Dentistry (LACBE-MDP), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), 3000-354 Coimbra, Portugal
- Center for Innovative Biomedicine and Biotecnhology (CIBB), 3000-354 Coimbra, Portugal
- Institute of Orthodontics, Faculty of Medicine, University of Coimbra, 3000-354 Coimbra, Portugal
| |
Collapse
|
21
|
Prodan CM, Gasparik C, Ruiz-López J, Dudea D. Color and Translucency Variation of a One-Shaded Resin-Based Composite after Repeated Heating Cycles and Staining. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16103793. [PMID: 37241420 DOI: 10.3390/ma16103793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 05/09/2023] [Accepted: 05/16/2023] [Indexed: 05/28/2023]
Abstract
(1) Background: This study aimed to determine the effect of repeated pre-polymerization heating on the color and translucency of a one-shaded resin-based composite and to evaluate whether the heating cycles affect its color stability. (2) Methods: Fifty-six samples of 1-mm thickness were fabricated from Omnichroma (OM) after applying different heating cycles (for one, five, and ten times at 45 °C) before polymerization (n = 14/group) and afterwards were stained with a yellow dye solution. CIE L*, a*, b*, C*, h° coordinates were recorded, and color differences, whiteness, and translucency were calculated, before and after staining. (3) Results: Heating cycles significantly influenced the color coordinates, WID00, and TP00 of OM being higher after one heating cycle and decreasing as the number of heating cycles increased. The color coordinates, WID, and TP00 after staining significantly differed for each group. The color and whiteness differences calculated after staining exceeded the acceptability thresholds for all groups. The color and whiteness variations after staining were clinically unacceptable. (4) Conclusions: Repeated pre-polymerization heating induces a clinically acceptable color and translucency change to OM. Although the color changes resulting after staining are clinically unacceptable, increasing the number of heating cycles up to ten times slightly reduces the color differences.
Collapse
Affiliation(s)
- Corina Mirela Prodan
- Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania
| | - Cristina Gasparik
- Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania
| | - Javier Ruiz-López
- Department of Optics, Faculty of Science, Campus de Fuente Nueva, Edificio Mecenas, University of Granada, ibs-Granada, 18071 Granada, Spain
| | - Diana Dudea
- Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj-Napoca, Romania
| |
Collapse
|
22
|
Nascimento Batista JM, Sinhoreti MAC, Alves Fraga MA, Manoel da Silva MV, Correr AB, Roulet JF, Geraldeli S. Effect of preheating on mechanical properties of a resin-based composite containing elastomeric urethane monomer. J Mech Behav Biomed Mater 2023; 141:105758. [PMID: 36934689 DOI: 10.1016/j.jmbbm.2023.105758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 03/08/2023]
Abstract
This study investigated the effect of preheating an elastomeric urethane monomer (Exothane-24) experimental resin composite on its physicochemical properties. Two resin matrices were formulated: (a) 50 wt% Bisphenol-glycidyl methacrylate (Bis-GMA) and 50 wt% triethylene glycol dimethacrylate (TEGDMA); and (b) 20 wt% Exothane-24, 40 wt% Bis-GMA and 40 wt% TEGDMA. A photoinitiator system (0.25 wt% camphorquinone and 0.50 wt% ethyl-4-dimethylamino benzoate) and 65 wt% of the inorganic filler (20 wt% 0.05 μm silica and 80 wt% 0.7 μm BaBSiO2 glass) were added to both matrices. These formulations were then assigned to four groups: Exothane-24 (E); Exothane-24 plus preheating (EH); no Exothane-24 (NE); and no Exothane-24 plus preheating (NEH). NEH and EH were preheated at 69 °C. The dependent variables were as follows: film thickness (FT); polymerization shrinkage stress (PSS); gap width (GW); maximum rate of polymerization (Rpmax); and degree of conversion (DC). Data were statistically analyzed by two-way ANOVA and Tukey's test (α = 0.05). Preheating reduced FT for both composites. PSS and GW were significantly lower for EH, when compared with E. The DC for EH and NEH and the Rpmax for EH increased significantly. Preheating improved most of the physicochemical properties (FT, PSS, GW, and DC) of the experimental resin composite containing Exothane-24.
Collapse
Affiliation(s)
- João Marcos Nascimento Batista
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Mário Alexandre Coelho Sinhoreti
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.
| | - May Anny Alves Fraga
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Marcus Vinícius Manoel da Silva
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Américo Bortolazzo Correr
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | - Jean-François Roulet
- Department of Restorative Dental Science, College of Dentistry, University of Florida, Gainesville, FL, USA
| | - Saulo Geraldeli
- Division of Biomedical Materials, School of Dental Medicine, East Carolina University, Greenville, NC, USA
| |
Collapse
|
23
|
Hordones Ribeiro MT, Felipe de Bragança G, Sales Oliveira LR, Lourenço Braga SS, Quirino de Oliveira HL, Price RB, Soares CJ. Effect of pre-heating methods and devices on the mechanical properties, post-gel shrinkage, and shrinkage stress of bulk-fill materials. J Mech Behav Biomed Mater 2023; 138:105605. [PMID: 36516543 DOI: 10.1016/j.jmbbm.2022.105605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 11/27/2022] [Accepted: 12/05/2022] [Indexed: 12/13/2022]
Abstract
This study evaluated the effect of using two different pre-heating methods on the three resin-based composite (RBCs). Three paste viscosity bulk-fill RBCs (VisCalor Bulk [VC]; VOCO; x-tra fil Caps [XF], VOCO; Filtek One Bulk Fill [FO], 3 M) were pre-heated using either a VisCalor Dispenser (VOCO) to 65 °C, or the Caps Warmer (VOCO) to 37 °C, 54 °C, or 68 °C. The temperature inside the capsules and cavity was monitored before and after insertion into the matrix. Within 30 s of inserting the RBC, they were light-activated using a VALO (Ultradent) curing light for 20 s. The post-gel shrinkage (Shr - %), Flexural Strength (FS - MPa), Elastic Modulus (E - MPa), degree of conversion (DC - %), Knoop Hardness (KH - N/mm2), diametral tensile strength (DTS - MPa), and compressive strength (CS - MPa) of the RBCs were measured (10 specimens per group). The shrinkage stress was calculated using three-dimensional finite element analysis. Data were analyzed using one-way, two-way ANOVA and Tukey's test (α = 0.05). The temperature fell rapidly after the RBC was inserted into the cavity. Pre-heating the RBCs did not affect the mechanical properties. FO had the lowest E, DC, and KH values, VC had intermediate values, and XF achieved the highest values. The DTS and CS values were not affected by the various pre-heating methods, the temperature, or RBC. Pre-heating methods at 37 °C produced higher shrinkage for all RBCs. VC pre-heated to 65 °C produced the lowest stress when measured at 10 min after light activation.
Collapse
Affiliation(s)
- Maria Tereza Hordones Ribeiro
- Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| | - Gabriel Felipe de Bragança
- Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| | - Laís Rani Sales Oliveira
- Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| | - Stella Sueli Lourenço Braga
- Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| | - Helena Letícia Quirino de Oliveira
- Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.
| | - Carlos José Soares
- Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| |
Collapse
|
24
|
Raposo CC, Nery LMS, Carvalho EM, Ferreira PVC, Ardenghi DM, Bauer J, Lima DM. Effect of preheating on the physicochemical properties and bond strength of composite resins utilized as dental cements: An in vitro study. J Prosthet Dent 2023; 129:229.e1-229.e7. [PMID: 36503853 DOI: 10.1016/j.prosdent.2022.11.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 11/04/2022] [Accepted: 11/07/2022] [Indexed: 12/13/2022]
Abstract
STATEMENT OF PROBLEM Little is known regarding the use of preheated composite resins to bond indirect restorations and its impact on mechanical properties when compared with resin cements. PURPOSE The purpose of this in vitro study was to compare the chemical and physical properties and bond strength to enamel and ceramics of preheated composite resins and resin cements. MATERIAL AND METHODS Two composite resins, the microhybrid Filtek Z250XT and the nanoparticulate Z350XT were tested, and 2 commercially available resin cements, the dual-polymerized Rely-X ARC and the light-polymerized Rely-X Veneer were used as controls. A device (HotSet) was used to preheat the composite resins to 69 °C before light-polymerization. The following properties were tested: flexural strength, modulus of elasticity, fracture toughness, microshear bond strength to enamel and ceramics, degree of conversion, flow, sorption and solubility, and color stability. Statistical analysis was done with ANOVA and Holm-Sidak for multiple comparisons (α=.05). RESULTS Preheating had no significant effect on the degree of conversion, flexural strength, fracture toughness, solubility, or microshear bond strength to the enamel of the tested composite resins (P>.05). However, preheating increased the sorption and reduced the microshear bond strength to the ceramic (P<.05). The flowability of the composite resins increased with heating but showed lower values when compared with both resin cements (P<.05). Color stability was more affected in the preheated composite resins than in the resin cements. CONCLUSIONS The preheating process resulted in little to no benefit in the evaluated properties for the composite resins. Resin cements appear to be the best option for cementing indirect restorations.
Collapse
Affiliation(s)
- Carolina Carramilo Raposo
- PhD student, Dentistry Biomaterials Laboratory (Biomma), School of Dentistry, Federal University of Maranhão (UFMA), São Luís, MA, Brazil
| | - Luanna Marinho Sereno Nery
- PhD student, Dentistry Biomaterials Laboratory (Biomma), School of Dentistry, Federal University of Maranhão (UFMA), São Luís, MA, Brazil
| | - Edilausson Moreno Carvalho
- Professor, Department of Restorative Dentistry, School of Dentistry, University Ceuma, (UNICEUMA) São Luís, MA, Brazil
| | - Paulo Vitor Campos Ferreira
- Professor, Dentistry Biomaterials Laboratory (Biomma), School of Dentistry, Federal University of Maranhão (UFMA), São Luís, MA, Brazil
| | - Diego Machado Ardenghi
- Professor, Department of Oral Health Sciences, Faculty of Dentistry, University of British Columbia (UBC), Vancouver, Canada
| | - José Bauer
- Professor, Dentistry Biomaterials Laboratory (Biomma), School of Dentistry, Federal University of Maranhão (UFMA), São Luís, MA, Brazil.
| | - Darlon Martins Lima
- Professor, Dentistry Biomaterials Laboratory (Biomma), School of Dentistry, Federal University of Maranhão (UFMA), São Luís, MA, Brazil
| |
Collapse
|
25
|
Patussi AFC, Ramacciato JC, da Silva JGR, Nascimento VRP, Campos DES, de Araújo Ferreira Munizz I, de Souza GM, Lima RBW. Preheating of dental composite resins: A scoping review. J ESTHET RESTOR DENT 2022; 35:646-656. [DOI: 10.1111/jerd.12991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 11/18/2022] [Accepted: 11/21/2022] [Indexed: 12/12/2022]
Affiliation(s)
| | | | | | | | - Débora e Silva Campos
- Department of Restorative Dentistry Universidade Federal da Paraíba João Pessoa Brazil
| | | | - Grace M. de Souza
- Departament of Comprehensive Dentistry University Louisville Louisville Kentucky USA
| | | |
Collapse
|
26
|
AL-Ashou WM, Taher R, Ali AH. Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study). Saudi Dent J 2022; 34:779-787. [PMID: 36570578 PMCID: PMC9767841 DOI: 10.1016/j.sdentj.2022.11.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 11/10/2022] [Accepted: 11/16/2022] [Indexed: 11/24/2022] Open
Abstract
This study aimed at comparing shear-bond strength (SBS) of different self-etching adhesive systems (Clearfil S3 Bond Plus, G-Premio BOND and IBond) to dentin without or with diode-laser irradiation before photo-polymerization and to determine the effect of storage and thermo-cycling on SBS of adhesive systems. METHODS The buccal surface of 84 extracted maxillary premolars was grounded to create flat surface. The specimens were allocated into 3 groups (n = 28) depending upon the adhesive systems, then each group was divided into two sub-group (I, II) (n = 14). After the placement of respective adhesive systems on the flat surface, adhesive system in group I was photo-polymerized immediately, while in group II, the adhesive systems were exposed to diode-laser before photo-polymerization. Composite cylinder (4 mm in diameter and 2 mm height) was built on the flat surface of each specimen. Then group I and II were divided into two sub-groups (n = 7) according to the storage time and thermo-cycling (1 day without thermo-cycling or 72 days with thermo-cycling) then all the specimens were stored in distilled water. The SBS was measured at the end of storage period. ANOVA, Duncan's Multiple Range Test and independent t-test "P ≤ 0.05" were used for data analysis. RESULTS G-premio BOND showed the highest mean value of SBS followed by Clearfil S3 Bond plus without significant difference between them, while IBond revealed the least mean value. Laser irradiation had positive effect on the bond-strength of all tested adhesive systems. The results also showed that the storage with thermo-cycling had negative effect on the bond-strength in groups without laser irradiation for all tested adhesive systems, while for groups with laser irradiation, the reduction in the bond-strength of all tested adhesive systems was not significant. CONCLUSION Diode-laser application prior to photo-polymerization of self-etch adhesive systems significantly increased the bond-strength to dentin and can increase the durability of composite adhesion.
Collapse
|
27
|
Radwanski M, Caporossi C, Lukomska-Szymanska M, Luzi A, Sauro S. Complicated Crown Fracture of Permanent Incisors: A Conservative Treatment Case Report and a Narrative Review. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 9:bioengineering9090481. [PMID: 36135027 PMCID: PMC9495796 DOI: 10.3390/bioengineering9090481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 09/04/2022] [Accepted: 09/13/2022] [Indexed: 12/03/2022]
Abstract
Dental trauma may have a severe impact on the social and psychological wellbeing of a patient. Most cases of dental injuries involve anterior teeth, especially the maxillary upper incisors. Crown fractures, with or without pulp exposure, are the most common trauma in permanent dentition. There are many methods of management, in which the initial state of the pulp, the time since the injury, and the presence of an accompanying injury play a key role. This case report aimed at showing a possible conservative treatment after complicated tooth fracture that consisted of partial pulpotomy followed by adhesive reattachment of the tooth fragment using a technique based on heated resin composite. Such a specific procedure represents a conservative approach to traumatic coronal lesions, providing a suitable opportunity to maintain the tooth vitality, aesthetics, and function. Indeed, reattachment of tooth fragment using a composite/adhesive is a simple technique to achieve excellent results in terms of aesthetic and function.
Collapse
Affiliation(s)
- Mateusz Radwanski
- Department of Endodontics Chair, Conservative Dentistry, Endodontics Medical University of Lodz, 251 Pomorska Str., 92-213 Lodz, Poland
| | | | - Monika Lukomska-Szymanska
- Department of General Dentistry, Medical University of Lodz, 251 Pomorska Str., 92-213 Lodz, Poland
- Correspondence: (M.L.-S.); (S.S.); Tel.: +48-426-757461 (M.L.-S.)
| | - Arlinda Luzi
- Group of Dental Biomaterials and Minimally Invasive Dentistry, Department of Dentistry, Cardenal Herrera-CEU Universities, C/Santiago Ramón y Cajal, s/n., Alfara del Patriarca, 46115 Valencia, Spain
| | - Salvatore Sauro
- Group of Dental Biomaterials and Minimally Invasive Dentistry, Department of Dentistry, Cardenal Herrera-CEU Universities, C/Santiago Ramón y Cajal, s/n., Alfara del Patriarca, 46115 Valencia, Spain
- Department of Therapeutic Dentistry, I. M. Sechenov First Moscow State Medical University, 119146 Moscow, Russia
- Correspondence: (M.L.-S.); (S.S.); Tel.: +48-426-757461 (M.L.-S.)
| |
Collapse
|
28
|
El-Askary F, Hassanein A, Aboalazm E, Al-Haj Husain N, Özcan M. A Comparison of Microtensile Bond Strength, Film Thickness, and Microhardness of Photo-Polymerized Luting Composites. MATERIALS 2022; 15:ma15093050. [PMID: 35591383 PMCID: PMC9102044 DOI: 10.3390/ma15093050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/07/2022] [Accepted: 04/20/2022] [Indexed: 02/04/2023]
Abstract
The aim of this study was to evaluate the effect of CAD/CAM composite thickness on micro-tensile bond strength (µTBS), microhardness (HV), and film thickness (FT) of different luting composites. Composite blocks (6.8 mm × 6.8 mm) were divided into 12 groups according to: CAD/CAM thickness and luting composite. For each group, 21 rods (1 mm × 1 mm) were tested in tension at crosshead speed of 1 mm/min. Fracture modes were categorized as adhesive, mixed, and cohesive. Microhardness (n = 5/group) was assessed using microhardness tester. Film thickness (12-rods/group) was evaluated using a stereomicroscope (×40). Data were analyzed using the two-way ANOVA/Tukey’s HSD test (p = 0.05). Parameters “thickness”, “cement”, and “thickness x cement” showed significant difference on µTBS and HV (p < 0.05). At 2 mm, heated x-tra fil composite showed the highest µTBS (45.0 ± 8.5 MPa), while at 4 mm thickness, Grandio Flow revealed the lowest µTBS (33.3 ± 6.3 MPa). Adhesive, mixed, and cohesive failures were reported. The HV of all composites decreased when photo-polymerized through 4 mm thickness (p < 0.05). Regardless of CAD/CAM thickness, photo-polymerized composites can be successfully used for luting CAD/CAM composite.
Collapse
Affiliation(s)
- Farid El-Askary
- Operative Dentistry Department, Faculty of Dentistry, Ain Shams University, Cairo 11566, Egypt
- Correspondence:
| | - Abdullah Hassanein
- Conservative Dentistry Department, Faculty of Oral and Dental Medicine, Egyptian-Russian University, Cairo 11829, Egypt; (A.H.); (E.A.)
| | - Emad Aboalazm
- Conservative Dentistry Department, Faculty of Oral and Dental Medicine, Egyptian-Russian University, Cairo 11829, Egypt; (A.H.); (E.A.)
| | - Nadin Al-Haj Husain
- Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (N.A.-H.H.); (M.Ö.)
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3008 Bern, Switzerland
| | - Mutlu Özcan
- Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, 8032 Zurich, Switzerland; (N.A.-H.H.); (M.Ö.)
| |
Collapse
|
29
|
Composite Resin Preheating Techniques for Cementation of Indirect Restorations. Int J Biomater 2022; 2022:5935668. [PMID: 35368409 PMCID: PMC8967568 DOI: 10.1155/2022/5935668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 02/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose Resin-based materials have been preheated by using different techniques and commercial devices. However, a consensus on the clinical protocol for cementing with preheated composite resins is lacking. The aim of this scoping review was to identify the different methods used for heating composite resins as used for cementing indirect adhesive restorations and to determine the benefits and limitations. Study Selection. A search was performed on PubMed/MEDLINE, Embase, Cochrane, Web of Science, Scopus, LIVIVO, and the nonpeer-reviewed literature database. Studies on preheating composite resins for cementing indirect restorations were included, with no restrictions on the type of study, year of publication, or language. The following data were extracted: preheating technique, the device used for preheating, preset temperature, and warming time. Results In total, 304 studies were identified. After removing duplicates, 270 articles were selected, and 14 articles were included in the final evaluation. Half of the included studies reported similar preheating techniques using the Calset device for composite resins. The temperatures of 54°C and 68°C were most frequently reported, with a mean warming time of 5 minutes. Conclusions Preheating composite resins for the cementation of indirect restorations reduces viscosity, but the material must be used promptly after removal from the device. Practical Implications. Different methodologies for preheating composite resins have been reported and used in clinical dental practice. To achieve good results and guide the clinician on use, the techniques for heating composite resins for cementation need to be standardized. Keeping the material warm until the restorative procedure, the thickness of the indirect restoration, and the composition of the composite resins can directly affect the outcome of the procedure.
Collapse
|
30
|
Almiro M, Marinho B, Delgado AHS, Rua J, Monteiro P, Santos IC, Proença L, Mendes JJ, Gresnigt MMM. Increasing Acid Concentration, Time and Using a Two-Part Silane Potentiates Bond Strength of Lithium Disilicate-Reinforced Glass Ceramic to Resin Composite: An Exploratory Laboratory Study. MATERIALS 2022; 15:ma15062045. [PMID: 35329495 PMCID: PMC8950098 DOI: 10.3390/ma15062045] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 02/21/2022] [Accepted: 03/04/2022] [Indexed: 02/04/2023]
Abstract
There is still a lack of consensus concerning the recommended etching concentration, application time and type of silane when bonding lithium disilicate-reinforced glass ceramics manufactured by CAD/CAM. The purpose of this study was thus to conduct an in vitro study which investigates the influence of hydrofluoric acid (HF) concentration, etching time and silane type on the microtensile bond strength (μTBS) of lithium disilicate to resin composites. Thirty-nine IPS e.max CAD blocks were randomly divided between thirteen groups (n = 3). The variables were HF concentration (9.5 or 4.9%), etching time (20 or 60 s) and silane type (Bis-Silane, Monobond Plus and ESPE Sil Silane). The blocks were cut into beams, aged for 10,000 cycles in a thermocycler and submitted to tensile stress to determine μTBS. A control group featuring the Monobond Etch & Prime (MEP) agent that combines etching/silanisation into a simultaneous process was also added. This group was discarded from the analysis due to only having pre-test failures. The data were analysed using a three-way ANOVA (α = 0.05). The HF concentration, etching time and silane type significantly influenced μTBS (p < 0.001). Significant interactions between time and silane type (p = 0.004), HF concentration and silane type (p < 0.001) and among the three factors (p < 0.001) were noted. Etching lithium disilicate with 9.5% HF (60 s), followed by the application of Bis-Silane, resulted in the highest μTBS (16.6 ± 9.0 MPa). The highest concentration and etching time under study, combined with a two-part silane, resulted in the highest bond strength, while the application of MEP showed a complete pre-test failure.
Collapse
Affiliation(s)
- Matilde Almiro
- Department of Conservative Dentistry, Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (M.A.); (B.M.)
| | - Beatriz Marinho
- Department of Conservative Dentistry, Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (M.A.); (B.M.)
| | - António H. S. Delgado
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
- Division of Biomaterials and Tissue Engineering, Eastman Dental Institute, University College London (UCL), London NW3 2PF, UK
| | - João Rua
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - Paulo Monteiro
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - Inês Caetano Santos
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - Luís Proença
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - José João Mendes
- Centro de Investigação Interdisciplinar Egas Moniz (CiiEM), Instituto Universitário Egas Moniz (IUEM), Monte de Caparica, 2829-511 Almada, Portugal; (A.H.S.D.); (J.R.); (P.M.); (I.C.S.); (L.P.); (J.J.M.)
| | - Marco M. M. Gresnigt
- University Medical Center Groningen, Department of Restorative Dentistry and Biomaterials, Center for Dentistry and Oral Hygiene, University of Groningen, 9713 AV Groningen, The Netherlands
- Department of Special Dental Care, Martini Hospital, 9728 NT Groningen, The Netherlands
- Faculty of Health Sciences, University Arthuro Prat, Iquique 2120, Chile
- Correspondence:
| |
Collapse
|
31
|
A systematic review and meta-analysis on using preheated resin composites as luting agents for indirect restorations. Clin Oral Investig 2022; 26:3383-3393. [PMID: 35149906 DOI: 10.1007/s00784-022-04406-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 02/06/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVES This systematic review investigated the hypothesis that preheated resin composites (RCs) used as luting agents improve the mechanical properties, physicochemical performance, and color of indirect ceramic restorations. MATERIALS AND METHODS Literature search was performed in three databases (Medline/PubMed, Scopus, and Web of Science) and in the grey literature (OpenGrey, ProQuest, and Catalog of Theses & Dissertations from CAPES). Eligibility criteria included only studies comparing at least one preheated RC used as a luting agent with resin cements. RESULTS Data regarding the mechanical properties, physicochemical characteristics, and color were analyzed qualitatively, and the microtensile bond strength and film thickness were also evaluated by meta-analysis. The search strategy identified 3894 papers, and 28 were full-text screened. Seven studies were included in the review, and 5 were included in the meta-analysis. No significant difference was found for microtensile bond strength (P = 0.14). Preheated RCs showed significantly higher film thickness than resin cements (P = 0.001). CONCLUSION Overall, the use of preheated RCs as luting agents offers similar to poorer performance than using resin cements for bonding indirect restorations. CLINICAL RELEVANCE Despite the claim that preheated RC could be used as a luting agent, further studies should investigate the effect of clinically unacceptable film thickness.
Collapse
|
32
|
Kimyai S, Mashayekhi Z, Mohammadi N, Bahari M, Abed Kahnamouei M, Ebrahimi Chaharom ME. Comparison of the effect of preheating on the flexural strength of giomer and nanohybrid composite resin. J Dent Res Dent Clin Dent Prospects 2022; 16:159-163. [PMID: 36704183 PMCID: PMC9871171 DOI: 10.34172/joddd.2022.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 10/08/2022] [Indexed: 01/20/2023] Open
Abstract
Background. Considering the increased use of preheating and novel resin-based materials to restore teeth, the present study investigated the impact of preheating on the flexural strength of a giomer and compared it with a nanohybrid composite resin. Methods. Two restorative materials (Beautifil II giomer and Alpha III nanohybrid composite resin) were used. Thirty rod-shaped samples (adding up to 60 samples) were prepared from the materials above and divided into two subgroups: with and without preheating (n=15). Before sample preparation, the giomer and nanohybrid composite resin tubes were preheated at 68ºC for 15 minutes in the preheating subgroups. In the subgroups without preheating, the tubes were kept in a room at 25ºC. Then the flexural strength was compared between the two groups with two-way ANOVA at a significance level of P<0.05. Results. The results showed significantly higher flexural strength in the preheated subgroups than in the non-preheated subgroups (P<0.001). In addition, the mean flexural strength values were significantly higher in the giomer groups than in the nanohybrid composite resin groups (P<0.001). Conclusion. Preheating increased the studied materials' flexural strengths significantly. The flexural strength of the giomer restorative material was higher than that of the nanohybrid composite resin, irrespective of preheating.
Collapse
Affiliation(s)
- Soodabeh Kimyai
- Dental and Periodontal Research Center, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran,Department of Operative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran,Corresponding author: Soodabeh Kimyai,
| | - Zahra Mashayekhi
- Department of Operative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Narmin Mohammadi
- Department of Operative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahmoud Bahari
- Department of Operative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahdi Abed Kahnamouei
- Department of Operative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | | |
Collapse
|
33
|
Dutta G, Sajjan G, Varma KM, Satish RK, Pulidindi A, Kolla V. One-year clinical evaluation of bulk-fill composite resin restorations plasticized by preheating and ultrasonics: A randomized clinical trial. J Conserv Dent 2022; 25:88-92. [PMID: 35722076 PMCID: PMC9200177 DOI: 10.4103/jcd.jcd_333_21] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 12/26/2021] [Accepted: 12/27/2021] [Indexed: 11/04/2022] Open
Abstract
Introduction: Aim: Methodology: Results: Conclusion:
Collapse
|
34
|
Ohse L, Stona D, Sly MM, Burnett Júnior LH, Spohr AM. Fracture strength of teeth restored with milled ultrathin occlusal veneers made of polymer-infiltrated ceramic. Braz Dent J 2021; 32:105-113. [PMID: 34877972 DOI: 10.1590/0103-6440202104530] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 09/24/2021] [Indexed: 11/22/2022] Open
Abstract
The purpose was to evaluate, in vitro, the fracture strength of teeth restored with 0.3- or 0.6-mm-thick occlusal veneers made of Vita Enamic® bonded to enamel or dentin. Fifty third molars were allocated into five groups (n=10): Group C - control (sound teeth); Group 0.3E - 0.3-mm-thick occlusal veneers bonded to enamel; Group 0.6E - 0.6-mm-thick occlusal veneers bonded to enamel; Group 0.3D - 0.3-mm-thick occlusal veneers bonded to dentin; Group 0.6D - 0.6-mm-thick occlusal veneers bonded to dentin. After luting with Single Bond Universal and Filtek Z-100, the samples were subjected to fracture strength test in a universal testing machine. The fractures were classified as irreparable and reparable. Data were analyzed with 2-way and 1-way ANOVA (α=.05) followed by Tukey's test. The teeth restored with 0.3-mm-thick occlusal veneers (2658 N) achieved significantly higher fracture strength compared to the teeth restored with 0.6-mm-thick occlusal veneers (2070 N) (p=0.017). The teeth restored with occlusal veneers bonded to enamel (2648 N) had significantly higher fracture strength compared to the teeth restored with occlusal veneers bonded to dentin (2049 N) (p=0.015). Group C (3355 N) and Group 0.3E (2965 N) did not differ significantly from each other, being the fracture strength significantly higher than the other groups (p<0.05). The fractures were predominantly reparable. The teeth restored with 0.3-mm-thick occlusal veneers achieved higher fracture strength compared to the teeth restored with 0.6-mm-thick occlusal veneers. The supporting substrate influenced the fracture strength, which was higher for the teeth restored with occlusal veneers bonded to enamel.
Collapse
Affiliation(s)
- Laerte Ohse
- Department of Restorative Dentistry, Pontifícia Universidade Católica do Rio Grande do Sul - PUC-RS, Porto Alegre, RS, Brazil
| | - Deborah Stona
- Department of Restorative Dentistry, Pontifícia Universidade Católica do Rio Grande do Sul - PUC-RS, Porto Alegre, RS, Brazil
| | - Marília M Sly
- Restorative Dentistry and Prosthodontics, Universtity of Texas, UTHealth Houston School of Dentistry, Texas, Houston, USA
| | - Luiz Henrique Burnett Júnior
- Department of Restorative Dentistry, Pontifícia Universidade Católica do Rio Grande do Sul - PUC-RS, Porto Alegre, RS, Brazil
| | - Ana Maria Spohr
- Department of Restorative Dentistry, Pontifícia Universidade Católica do Rio Grande do Sul - PUC-RS, Porto Alegre, RS, Brazil
| |
Collapse
|
35
|
Pre-endodontic restoration of structurally compromised teeth: current concepts. Br Dent J 2021; 231:343-349. [PMID: 34561585 PMCID: PMC8463293 DOI: 10.1038/s41415-021-3467-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 02/21/2021] [Indexed: 11/29/2022]
Abstract
Teeth that require endodontic treatment are often structurally compromised and this considerably complicates endodontic procedures. Therefore, pre-endodontic restoration is a key approach that dentists should consider for such teeth. This article discusses current concepts of pre-endodontic restoration, with a focus on adhesive restorative methods and surgical/orthodontic techniques, and provides a relevant decision-making flowchart. Highlights the importance of pre-endodontic restoration for the predictability of endodontic treatment. Discusses restorability aspects for structurally compromised teeth. Reviews current restorative and surgical/orthodontic techniques for pre-endodontic restoration and provides a decision-making flowchart.
Collapse
|
36
|
Gebril M, Grüll MP, Brillant MS, Sullivan B, Price RB. Effect of repeated heating and cooling cycles on the degree of conversion and microhardness of four resin composites. J ESTHET RESTOR DENT 2021; 33:1201-1209. [PMID: 34424606 DOI: 10.1111/jerd.12815] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 08/06/2021] [Accepted: 08/09/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE This study evaluated the effect of repeatedly heating and cooling four resin-based composites (RBCs) for up to six cycles. MATERIALS AND METHODS Four commercial RBCs were heated to 68°C and cooled to room temperature for up to six cycles before photocuring at 30°C. Specimens spent a total of 0, 30, 60, 90, 120, 150 min, or 7 days at 68°C. The degree of conversion (DC) was measured at the bottom of the specimens immediately after photocuring. The Vickers microhardness was measured at the top and bottom of the RBC surfaces 24 h after photocuring. The data were analyzed using one-way analysis of variance, Dunnett's or Bonferroni post-hoc tests, and Spearman correlation analysis (α = 0.05). RESULTS For two brands of RBC, the DC decreased at various time points; however, these decreases were small, and there was no correlation (negative or positive) between the number of heating cycles and the DC for any of the RBCs. Repeated heated and cooling resulted in small changes in the hardness (compared to the control) in both directions (Dunnett; p < 0.05). Two of the RBCs showed a significant, positive correlation between the number of heating cycles and their hardness at the bottom surface. CONCLUSION Repeated heating, cooling, and then reheating the RBCs for up to 1 week had little overall effect on their DC and microhardness values. The 2 mm thick specimens of all four RBCs achieved a bottom: top hardness ratio exceeding 0.8 after a 20 s exposure to light from a commercial LED curing light CLINICAL SIGNIFICANCE: Six repeated dry heating and cooling cycles of up to 1 week in duration had little effect on the DC and the microhardness of four commercial resin-based composites.
Collapse
Affiliation(s)
- Mohamed Gebril
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Canada
| | - Marc P Grüll
- Faculty of Dentistry, Dalhousie University, Halifax, Canada
| | | | | | - Richard B Price
- Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, Canada
| |
Collapse
|
37
|
Sun C, Xu D, Hou C, Zhang H, Li Y, Zhang Q, Wang H, Zhu M. Core-shell structured SiO 2@ZrO 2@SiO 2 filler for radiopacity and ultra-low shrinkage dental composite resins. J Mech Behav Biomed Mater 2021; 121:104593. [PMID: 34090118 DOI: 10.1016/j.jmbbm.2021.104593] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 05/09/2021] [Accepted: 05/11/2021] [Indexed: 11/15/2022]
Abstract
To overcome the interfacial problem between X-ray radiopaque ZrO2 fillers and polymer resin in dental composites, monodispersed SiO2@ZrO2@SiO2 (SZS) microspheres with narrow size distribution were prepared by a controlled sol-gel method. In the presence of SiO2 coating layer over SiO2@ZrO2 (SZ) microspheres, they were easily silanized same as SiO2 microspheres. Ethoxylated bisphenol A dimethacrylate (EBPADMA) with a higher molecular weight and a lower viscosity was used as base resin monomer mixed with a low amount of diluent triethylene glycol dimethacrylate (TEGDMA). Additionally, the addition of a small amount of pore agent acetone dicarboxylic acid (ADCA) produced some voids, thereby effectively reducing the polymerization shrinkage of the resin. The prepared dental composites combining 52 wt% monodispersed silica microsphere, 20 wt% SZS microspheres, exhibited significantly enhanced capacity in radiopacity (higher than tooth enamel) and very low shrinkage (<0.1%). It also has better mechanical properties than resin composites filled with SiO2 microspheres, and its strength can meet practical applications. The properties of the radiopaque dental composite were to be further tuned by varying the amount of SZS microspheres contents, and the radiopaque resin has an advantage over the commercial one in that it is clinically nondestructive.
Collapse
Affiliation(s)
- Chuanyue Sun
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, PR China
| | - Dongyu Xu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, PR China
| | - Chengyi Hou
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, PR China
| | - Hui Zhang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, PR China.
| | - Yaogang Li
- Engineering Research Center of Advanced Glasses Manufacturing Technology, Ministry of Education, Donghua University, Shanghai, 201620, PR China
| | - Qinghong Zhang
- Engineering Research Center of Advanced Glasses Manufacturing Technology, Ministry of Education, Donghua University, Shanghai, 201620, PR China.
| | - Hongzhi Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, PR China
| | - Meifang Zhu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, PR China
| |
Collapse
|
38
|
Ferracane JL, Lawson NC. Probing the hierarchy of evidence to identify the best strategy for placing class II dental composite restorations using current materials. J ESTHET RESTOR DENT 2020; 33:39-50. [PMID: 33206440 DOI: 10.1111/jerd.12686] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Accepted: 11/02/2020] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The objective of this review is to present a synopsis of the existing clinical and in vitro evidence regarding placement of direct class II restorations with dental composites of varying viscosities, focusing on the marginal integrity achievable. OVERVIEW The literature on class II composites placed with various techniques was searched through PubMed, Scopus, and the citations of identified articles, focusing on aspects related to adaptation and clinical performance. Studies comparing layering of conventional composite to layering with a flowable liner, including the "snow plow technique," use of warmed composite, flowable bulk-fill liners with a conventional composite capping layer, and bulk-fill restorative in a single or incremental fill (including placement with sonic energy and dual-curing) CONCLUSIONS: In vitro and clinical evidence does not support any one specific method or material type for achieving optimal performance when restoring class II cavity preparations with current dental composites. CLINICAL SIGNIFICANCE Although there are many available placement methods and types of composite materials on the market for use in class II restorations, the reasonable success presented in the clinical and laboratory literature for the various approaches suggests that the most important factor for achieving success is likely careful and proper placement and light-curing technique, independent of the approach.
Collapse
Affiliation(s)
- Jack L Ferracane
- Department of Restorative Dentistry, Oregon Health and Science University, School of Dentistry, Portland, Oregon, USA
| | - Nathaniel C Lawson
- Division of Biomaterials, University of Alabama at Birmingham, School of Dentistry, Birmingham, Alabama, USA
| |
Collapse
|