• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4634180)   Today's Articles (2312)   Subscriber (49987)
For: Goiato MC, Pellizzer EP, da Silva EVF, Bonatto LDR, dos Santos DM. Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review. Oral Maxillofac Surg 2015;19:229-242. [PMID: 25910993 DOI: 10.1007/s10006-015-0494-5] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Accepted: 03/26/2015] [Indexed: 05/28/2023]
Number Cited by Other Article(s)
1
Sharon E, Engel I. The Effect of Prosthetic Factors on the Long-Term Survival of Dental Implants: A Narrative Review. Oral Maxillofac Surg Clin North Am 2024:S1042-3699(24)00060-8. [PMID: 39261213 DOI: 10.1016/j.coms.2024.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/13/2024]
2
Ribeiro MCDO, Vargas-Moreno VF, Gomes RS, Faot F, Del Bel Cury AA, Marcello-Machado RM. Implant-supported crowns with locking taper implant-abutment connection: A systematic review and meta-analysis. J Prosthet Dent 2024;132:369-380. [PMID: 35864024 DOI: 10.1016/j.prosdent.2022.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 06/09/2022] [Accepted: 06/09/2022] [Indexed: 10/17/2022]
3
Aung YT, Eo MY, Sodnom-Ish B, Kim MJ, Kim SM. Long-term survival rates of tapered self-tapping bone-level implants after immediate placement: a positional effective rationale. Maxillofac Plast Reconstr Surg 2024;46:17. [PMID: 38727979 PMCID: PMC11087388 DOI: 10.1186/s40902-024-00428-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2024] [Accepted: 05/02/2024] [Indexed: 05/13/2024]  Open
4
Vinhas AS, Salazar F, Mendes JM, Silva AS, Ríos-Carrasco B, Ríos-Santos JV, Gil J, Herrero-Climent M, Aroso C. SEM Analysis and Micro-CT Evaluation of Four Dental Implants after Three Different Mechanical Requests-In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2024;17:434. [PMID: 38255602 PMCID: PMC10820107 DOI: 10.3390/ma17020434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/24/2023] [Accepted: 01/07/2024] [Indexed: 01/24/2024]
5
Shen L, Dong C, Chen J, Bai X, Yang F, Wang L. The mechanical and clinical influences of prosthetic index structure in Morse taper implant-abutment connection: a scoping review. BMC Oral Health 2023;23:775. [PMID: 37865734 PMCID: PMC10590505 DOI: 10.1186/s12903-023-03545-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Accepted: 10/16/2023] [Indexed: 10/23/2023]  Open
6
Verma V, Hazari P, Verma P. Biomechanical efficiency of different implant-abutment connection: a systematic review of studies using photoelastic stress analysis. Evid Based Dent 2023;24:92. [PMID: 37188921 DOI: 10.1038/s41432-023-00884-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 03/22/2023] [Indexed: 05/17/2023]
7
Mendes TA, Vilhena L, Portugal J, Caramês J, Ramalho AL, Lopes LP. Wear of Titanium Implant Platforms with Different Abutment Connections and Abutment Materials: A Pilot Study. J Funct Biomater 2023;14:jfb14040178. [PMID: 37103268 PMCID: PMC10146395 DOI: 10.3390/jfb14040178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/21/2023] [Accepted: 03/22/2023] [Indexed: 04/28/2023]  Open
8
Hariharan AS, Sivaswamy V, Subhashini R. Implant-Abutment Connections: A Structured Review. J Long Term Eff Med Implants 2022;33:47-56. [PMID: 36382704 DOI: 10.1615/jlongtermeffmedimplants.2022042610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
9
Bacterial infiltration and detorque at the implant abutment morse taper interface after masticatory simulation. Sci Rep 2022;12:17103. [PMID: 36224228 PMCID: PMC9556662 DOI: 10.1038/s41598-022-20915-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 09/20/2022] [Indexed: 01/04/2023]  Open
10
Marginal Bone Loss in Internal Conical Connection Implants Placed at the Crestal and Subcrestal Levels before Prosthetic Loading: A Randomized Clinical Study. MATERIALS 2022;15:ma15103729. [PMID: 35629754 PMCID: PMC9145780 DOI: 10.3390/ma15103729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 05/17/2022] [Accepted: 05/18/2022] [Indexed: 12/04/2022]
11
In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs. MATERIALS 2022;15:ma15041392. [PMID: 35207933 PMCID: PMC8879145 DOI: 10.3390/ma15041392] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 02/02/2022] [Accepted: 02/10/2022] [Indexed: 02/04/2023]
12
Shah AH, Patel P, Trivedi A, Shah A, Desai N, Talati M. A comparison of marginal bone loss, survival rate, and prosthetic complications in implant-supported splinted and nonsplinted restorations: A systematic review and meta-analysis. J Indian Prosthodont Soc 2022;22:111-121. [PMID: 36511022 PMCID: PMC9132503 DOI: 10.4103/jips.jips_365_21] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]  Open
13
Friedmann A, Winkler M, Diehl D, Yildiz MS, Bilhan H. One-year performance of posterior narrow diameter implants in hyperglycemic and normo-glycemic patients-a pilot study. Clin Oral Investig 2021;25:6707-6715. [PMID: 33939006 PMCID: PMC8602141 DOI: 10.1007/s00784-021-03957-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 04/19/2021] [Indexed: 12/14/2022]
14
Bittencourt ABBC, Neto CLDMM, Penitente PA, Pellizzer EP, Dos Santos DM, Goiato MC. Comparison of the Morse Cone Connection with the Internal Hexagon and External Hexagon Connections Based on Microleakage - Review. Prague Med Rep 2021;122:181-190. [PMID: 34606430 DOI: 10.14712/23362936.2021.15] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]  Open
15
Asbi T, Hussein HA, Horwitz J, Gabay E, Machtei EE, Giladi HZ. A single application of chlorhexidine gel reduces gingival inflammation and interleukin 1-β following one-stage implant placement: A randomized controlled study. Clin Implant Dent Relat Res 2021;23:726-734. [PMID: 34378862 DOI: 10.1111/cid.13041] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 07/14/2021] [Accepted: 08/02/2021] [Indexed: 12/24/2022]
16
Moergel M, Rocha S, Messias A, Nicolau P, Guerra F, Wagner W. Clinical and radiographic performance of self-locking conical connection implants in the posterior mandible: Five-year results of a two-centre prospective study. Clin Oral Implants Res 2021;32:998-1007. [PMID: 34115893 PMCID: PMC8457113 DOI: 10.1111/clr.13794] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 05/09/2021] [Accepted: 05/23/2021] [Indexed: 12/12/2022]
17
Tokgöz SE, Bilhan H. The influence of the implant-abutment complex on marginal bone and peri-implant conditions: A retrospective study. J Adv Prosthodont 2021;13:46-54. [PMID: 33747394 PMCID: PMC7943754 DOI: 10.4047/jap.2021.13.1.46] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 02/02/2021] [Accepted: 02/05/2021] [Indexed: 11/23/2022]  Open
18
D’Addazio G, Sinjari B, Arcuri L, Femminella B, Murmura G, Santilli M, Caputi S. Mechanical Pull-Out Test of a New Hybrid Fixture-Abutment Connection: An In Vitro Study. MATERIALS 2021;14:ma14061555. [PMID: 33810040 PMCID: PMC8004755 DOI: 10.3390/ma14061555] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 03/06/2021] [Accepted: 03/18/2021] [Indexed: 11/16/2022]
19
Cytotoxic effects of submicron- and nano-scale titanium debris released from dental implants: an integrative review. Clin Oral Investig 2021;25:1627-1640. [PMID: 33616805 DOI: 10.1007/s00784-021-03785-z] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 01/07/2021] [Indexed: 12/12/2022]
20
Montero J. A Review of the Major Prosthetic Factors Influencing the Prognosis of Implant Prosthodontics. J Clin Med 2021;10:jcm10040816. [PMID: 33671394 PMCID: PMC7921991 DOI: 10.3390/jcm10040816] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/28/2021] [Accepted: 02/15/2021] [Indexed: 11/16/2022]  Open
21
Sicilia A, Gallego L, Sicilia P, Mallo C, Cuesta S, Sanz M. Crestal bone loss associated with different implant surfaces in the posterior mandible in patients with a history of periodontitis. A retrospective study. Clin Oral Implants Res 2021;32:88-99. [PMID: 33210774 DOI: 10.1111/clr.13682] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 08/26/2020] [Accepted: 10/25/2020] [Indexed: 12/26/2022]
22
Yu P, Zhi Li, Tan X, Yu H. Effect of sealing gel on the microleakage resistance and mechanical behavior during dynamic loading of 3 implant systems. J Prosthet Dent 2020;127:308-317. [PMID: 33246561 DOI: 10.1016/j.prosdent.2020.05.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 05/20/2020] [Accepted: 05/20/2020] [Indexed: 02/05/2023]
23
Vinhas AS, Aroso C, Salazar F, López-Jarana P, Ríos-Santos JV, Herrero-Climent M. Review of the Mechanical Behavior of Different Implant-Abutment Connections. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020;17:ijerph17228685. [PMID: 33238476 PMCID: PMC7700386 DOI: 10.3390/ijerph17228685] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 11/13/2020] [Accepted: 11/17/2020] [Indexed: 12/20/2022]
24
Marginal Bone Loss in Implants with External Connection versus Internal Conical Connection Prior to Prosthetic Loading. A Randomized Clinical Study. COATINGS 2020. [DOI: 10.3390/coatings10111044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
25
Al-Sawaf O, Tuna T, Rittich A, Kern T, Wolfart S. Randomized clinical trial evaluating the effect of splinting crowns on short implants in the mandible 3 years after loading. Clin Oral Implants Res 2020;31:1061-1071. [PMID: 33463774 DOI: 10.1111/clr.13652] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 08/10/2020] [Accepted: 08/10/2020] [Indexed: 12/25/2022]
26
Farronato D, Pasini PM, Orsina AA, Manfredini M, Azzi L, Farronato M. Correlation between Buccal Bone Thickness at Implant Placement in Healed Sites and Buccal Soft Tissue Maturation Pattern: A Prospective Three-Year Study. MATERIALS 2020;13:ma13030511. [PMID: 31973195 PMCID: PMC7040578 DOI: 10.3390/ma13030511] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 01/14/2020] [Accepted: 01/19/2020] [Indexed: 02/07/2023]
27
Meijndert CM, Raghoebar GM, Santing HJ, Vissink A, Meijer HJA. Performance of bone-level implants with conical connections in the anterior maxilla: A 5-year prospective cohort study. Clin Oral Implants Res 2019;31:173-180. [PMID: 31677294 DOI: 10.1111/clr.13553] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 10/16/2019] [Accepted: 10/19/2019] [Indexed: 11/27/2022]
28
Jung WK, Lee WS, Kwon HB. Effects of abutment screw preload in two implant connection systems: A 3D finite element study. J Prosthet Dent 2019;122:474.e1-474.e8. [DOI: 10.1016/j.prosdent.2019.04.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 04/19/2019] [Accepted: 04/19/2019] [Indexed: 10/25/2022]
29
External Connection versus Internal Connection in Dental Implantology. A Mechanical in vitro Study. METALS 2019. [DOI: 10.3390/met9101106] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
30
do Nascimento C, Nogueira Fernandes FHC, Teixeira W, Pedrazzi V. Iodoform and silver-coated abutments preventing bacterial leakage through the implant-abutment interfaces: In vitro analysis using molecular-based method. Arch Oral Biol 2019;105:65-71. [PMID: 31276940 DOI: 10.1016/j.archoralbio.2019.06.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 06/06/2019] [Accepted: 06/26/2019] [Indexed: 10/26/2022]
31
He Y, Fok A, Aparicio C, Teng W. Contact analysis of gap formation at dental implant-abutment interface under oblique loading: A numerical-experimental study. Clin Implant Dent Relat Res 2019;21:741-752. [PMID: 31087510 DOI: 10.1111/cid.12792] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Revised: 03/25/2019] [Accepted: 04/23/2019] [Indexed: 12/19/2022]
32
Lee DW, Kim NH, Lee Y, Oh YA, Lee JH, You HK. Implant fracture failure rate and potential associated risk indicators: An up to 12-year retrospective study of implants in 5,124 patients. Clin Oral Implants Res 2019;30:206-217. [PMID: 30672029 DOI: 10.1111/clr.13407] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2018] [Revised: 01/12/2019] [Accepted: 01/15/2019] [Indexed: 12/16/2022]
33
Wachtel A, Zimmermann T, Sütel M, Adali U, Abou-Emara M, Müller WD, Mühlemann S, Schwitalla AD. Bacterial leakage and bending moments of screw-retained, composite-veneered PEEK implant crowns. J Mech Behav Biomed Mater 2018;91:32-37. [PMID: 30529984 DOI: 10.1016/j.jmbbm.2018.11.027] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 11/26/2018] [Accepted: 11/27/2018] [Indexed: 10/27/2022]
34
BASTOS JMC, BORDIN D, VASCONCELLOS AAD, MIRANDA ME. Influence of cantilever position and implant connection in a zirconia custom implant-supported fixed partial prosthesis: in silico analysis. REVISTA DE ODONTOLOGIA DA UNESP 2018. [DOI: 10.1590/1807-2577.06718] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]  Open
35
de Souza Batista VE, Verri FR, Lemos CAA, Cruz RS, Oliveira HFF, Gomes JML, Pellizzer EP. Should the restoration of adjacent implants be splinted or nonsplinted? A systematic review and meta-analysis. J Prosthet Dent 2018;121:41-51. [PMID: 29961632 DOI: 10.1016/j.prosdent.2018.03.004] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 03/02/2018] [Accepted: 03/02/2018] [Indexed: 10/28/2022]
36
Kim DH, Kim HJ, Kim S, Koo KT, Kim TI, Seol YJ, Lee YM, Ku Y, Rhyu IC. Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease. J Periodontal Implant Sci 2018;48:103-113. [PMID: 29770239 PMCID: PMC5944221 DOI: 10.5051/jpis.2018.48.2.103] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Accepted: 04/22/2018] [Indexed: 11/08/2022]  Open
37
Gallego L, Sicilia A, Sicilia P, Mallo C, Cuesta S, Sanz M. A retrospective study on the crestal bone loss associated with different implant surfaces in chronic periodontitis patients under maintenance. Clin Oral Implants Res 2018;29:557-567. [DOI: 10.1111/clr.13153] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/16/2018] [Indexed: 01/21/2023]
38
Schwitalla AD, Zimmermann T, Spintig T, Abou-Emara M, Lackmann J, Müller WD, Houshmand A. Maximum insertion torque of a novel implant-abutment-interface design for PEEK dental implants. J Mech Behav Biomed Mater 2017;77:85-89. [PMID: 28898725 DOI: 10.1016/j.jmbbm.2017.09.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2017] [Revised: 08/29/2017] [Accepted: 09/03/2017] [Indexed: 11/25/2022]
39
Apaza-Bedoya K, Tarce M, Benfatti CAM, Henriques B, Mathew MT, Teughels W, Souza JCM. Synergistic interactions between corrosion and wear at titanium-based dental implant connections: A scoping review. J Periodontal Res 2017;52:946-954. [DOI: 10.1111/jre.12469] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/05/2017] [Indexed: 01/15/2023]
40
Minatel L, Verri FR, Kudo GAH, de Faria Almeida DA, de Souza Batista VE, Lemos CAA, Pellizzer EP, Santiago JF. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017;71:35-42. [DOI: 10.1016/j.msec.2016.09.062] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2016] [Revised: 09/17/2016] [Accepted: 09/27/2016] [Indexed: 10/20/2022]
41
Are intra-articular injections of hyaluronic acid effective for the treatment of temporomandibular disorders? A systematic review. Int J Oral Maxillofac Surg 2016;45:1531-1537. [DOI: 10.1016/j.ijom.2016.06.004] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 03/14/2016] [Accepted: 06/06/2016] [Indexed: 11/19/2022]
42
Santiago JF, Verri FR, Almeida DADF, de Souza Batista VE, Lemos CAA, Pellizzer EP. Finite element analysis on influence of implant surface treatments, connection and bone types. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016;63:292-300. [DOI: 10.1016/j.msec.2016.02.061] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 02/02/2016] [Accepted: 02/19/2016] [Indexed: 11/27/2022]
43
Peruzetto WM, Martinez EF, Peruzzo DC, Joly JC, Napimoga MH. Microbiological Seal of Two Types of Tapered Implant Connections. Braz Dent J 2016;27:273-7. [PMID: 27224559 DOI: 10.1590/0103-6440201600604] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Accepted: 04/04/2016] [Indexed: 11/22/2022]  Open
44
In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection. Int J Biomater 2016;2016:8527849. [PMID: 27242903 PMCID: PMC4868898 DOI: 10.1155/2016/8527849] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Revised: 03/12/2016] [Accepted: 04/13/2016] [Indexed: 11/21/2022]  Open
PrevPage 1 of 1 1Next