1
|
Grillo A, Hyder Z, Mudera V, Kureshi A. Evaluation of hernia surgical meshes sterilised with ethylene oxide for adoption under UK regulations. Surg Endosc 2023; 37:9556-9562. [PMID: 37730855 PMCID: PMC10709235 DOI: 10.1007/s00464-023-10460-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 09/06/2023] [Indexed: 09/22/2023]
Abstract
BACKGROUND Low-cost meshes (LCM) have been successfully used in low-income countries (LIC) over the past decades, demonstrating comparable surgical outcomes to commercial meshes at a fraction of the cost. However, LIC sterilisation standards (autoclave sterilisation at 121 °C) do not meet UK regulations for medical devices, which require either ethylene oxide (EO) sterilisation or steam sterilisation at 134 °C. Therefore, the aim of this study was to sterilise UK LCM and characterise their mechanical properties and in vitro biocompatibility to verify whether EO sterilisation causes changes in the mechanical properties and biocompatibility of LCM. METHODS EO sterilised LCM were used. Uniaxial tensile tests were performed to measure mechanical properties. Biocompatibility was measured through viability and morphology of Human Dermal Fibroblasts (HDFs) cultured in mesh-conditioned media, and by calculating the metabolic activity and proliferation of HDFs attached on the meshes, with alamarBlue assay. RESULTS Break stress of LCM1 was significantly higher than LCM2 (p < 0.0001), while Young's modulus of LCM1 was significantly lower than LCM2 (p < 0.05) and there was no significant difference in break strain. Viability and morphology showed no significant difference between LCM and control. Attachment and proliferation of HDFs on LCM showed a better proliferation on LCM2 than LCM1, with values similar to the control at the final time point. CONCLUSIONS We demonstrated that EO sterilisation affects LCM mechanical properties, but they still have values closer to the native tissues than the commercially available ones. We also showed that in vitro biocompatibility of LCM2 is not affected by EO sterilisation, as HDFs attached and proliferated on the mesh, while EO affected attachment on LCM1. A more detailed cost analysis of the potential savings for healthcare systems around the world needs to be performed to strengthen the cost-effectiveness of this frugal innovation.
Collapse
Affiliation(s)
- Alessandra Grillo
- Centre for 3D Models of Health and Disease, Division of Surgery & Interventional Science, UCL, London, UK.
| | - Zargham Hyder
- Hydermed Limited, Woodford Green, UK
- Homerton University Hospital, NHS Trust, London, UK
| | - Vivek Mudera
- Centre for 3D Models of Health and Disease, Division of Surgery & Interventional Science, UCL, London, UK
| | - Alvena Kureshi
- Centre for 3D Models of Health and Disease, Division of Surgery & Interventional Science, UCL, London, UK
| |
Collapse
|
2
|
Adult groin hernia surgery in sub-Saharan Africa: a 20-year systematic review and meta-analysis. Hernia 2023; 27:157-172. [PMID: 36066755 DOI: 10.1007/s10029-022-02669-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 08/25/2022] [Indexed: 11/04/2022]
Abstract
PURPOSE To realize a systematic review to evaluate groin hernia surgery for adults in sub-Saharan Africa. METHODS We conducted a systematic review and meta-analysis, the primary objective of which was to determine the surgical techniques used for unilateral groin hernia surgery in sub-Saharan Africa. Studies published in the last 20 years were considered. A meta-analysis estimated the pooled prevalence with 95% confidence interval (CI) of mortality, chronic pain and recurrence. A subgroup analysis compared the rate of complications between complicated or uncomplicated hernia. RESULTS We included 113 articles. The most used technique was Bassini in 40.1%, followed by Lichtenstein in 29.9% and Shouldice in 12.6%. The overall mortality rate was 0.6% (95% CI 0.4-0.9). The pooled recurrence rate was 1.4% (95% CI 1.05-1.9). The pooled rate of chronic pain was 2.7% (95% CI 1.9-3.7). We found that mortality rate for complicated hernias (6.4%) was higher compared to uncomplicated hernias (0.2%). This difference was statistically significant [p ≤ 0.001; OR = 47.7; 95 CI (27.2-83.47)]. CONCLUSION This review showed that pure tissue repairs are the most used techniques with Bassini and Shouldice as leading procedures. The post-operative rates of recurrence and chronic pain are low. However, there is a high heterogeneity between studies than can underestimate these pooled prevalences. The consultation at complication stage remains frequent and associated with a higher mortality. Futures studies should focus on improving the quality of studies in terms of design and follow-up to increase the degree of evidence.
Collapse
|
3
|
Chate NN, Motiram NS, Jogdand BM, Birajdar MD. Study of Operative Outcomes of Hernioplasty Using Mosquito Net Mesh at a Tertiary Hospital. Cureus 2022; 14:e28525. [PMID: 36185890 PMCID: PMC9514146 DOI: 10.7759/cureus.28525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 08/28/2022] [Indexed: 11/22/2022] Open
Abstract
Background Synthetic mesh is the most efficient way to repair groin hernias. However, many patients in low and middle-income countries cannot afford the above-mentioned mesh. This study's goal was to describe the mosquito net mesh's (MNM) safety, viability, complications, and recurrence rate in hernioplasty done in rural populations. Material and methods This study was a single-centre, prospective, descriptive study, conducted in patients >18 years of age, of either gender, with unilateral or bilateral primary inguinal hernias (reducible/irreducible/bilateral hernia), admitted for elective or emergency open inguinal hernia mesh repair. The surgery was performed using reasonably priced (affordable to people of low socioeconomic status) polyethylene mosquito net mesh, which was cut into 8x16 cm rectangles and wrapped in two sealed plastic bags. They were sterilised using the ethylene oxide sterilisation (EtO) method. The type of hernia (unilateral or bilateral), post-operative pain, and complications were noted. Results Among 400 study participants, the incidence of inguinal hernia was highest in the 60-79 year age group (51.5%). Direct inguinal hernia (67.5 %) was higher compared to indirect inguinal hernia (32.5 %). While a majority of the participants had a hernia on the right side (50%), 164 patients (41%) had a hernia on the left side, and 36 patients (9%) had a bilateral inguinal hernia. The average operative time for unilateral inguinal hernia was 73.96 minutes and for bilateral inguinal hernia was 106.66 minutes. Out of 400 patients, 355 patients (88.75%) had no complications. Among the postoperative patients, 14 patients (3.5%) experienced surgical site infection; 9 patients (2.25%) experienced headache; 5 patients (1.25%) experienced hematoma; 12 patients (3%) experienced urinary retention; and 5 patients (1.25%) experienced testicular pain. The average hospital stay of patients was 4.25 days. Patients returned to their daily activities and employment in an average of 7.29 days. The market cost of a single standard polypropylene mesh was Rs.1,660/-. For making a single mosquito net mesh of the same size, we had an expenditure of Rs. 11.83/- including the cost of sterilization. In this study, 382 patients (95.5%) gave us good feedback, 11 patients (2.75) gave satisfactory feedback, and 7 patients (1.75%) gave excellent feedback. Conclusion In environments with limited resources, using mosquito net mesh for hernioplasty is reasonable, acceptable, doable, and economical.
Collapse
|
4
|
In vitro characterisation of low-cost synthetic meshes intended for hernia repair in the UK. Hernia 2021; 26:325-334. [PMID: 33797680 PMCID: PMC8881267 DOI: 10.1007/s10029-021-02401-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 03/17/2021] [Indexed: 11/20/2022]
Abstract
Purpose Low-cost meshes (LCM) were repurposed for the repair of hernias in the developing world. In vivo studies have shown LCM to have comparable results to commercial meshes (CM) at a fraction of the cost. However, little has been done to characterise the mechanical and biocompatible properties of LCM, preventing its clinical use in the UK. The objectives of the research are to assess mechanical and ultrastructural properties of two UK-sourced low-cost meshes (LCM) and the characterisation of the LCMs in vitro biocompatibility. Methods Mechanical properties of the two LCM were measured through uniaxial tensile test and ultrastructure was evaluated with Scanning Electron Microscopy. LIVE/DEAD® Viability/Cytotoxicity Assay kit and alamarBlue were used to assess cellular viability and proliferation, respectively. Images were acquired with a fluorescence microscope and analysed using ImageJ (NIH, USA). Results LCM1 and LCM2 were both multifilament meshes, with the first having smaller pores than the latter. LCM1 exhibited significantly higher tensile strength (p < 0.05) than LCM2 but significantly lower extensibility (p < 0.0001), while Young’s Modulus of the two samples was not significantly different. No significant difference was found in the cellular viability and morphology cultured in LCM1 and LCM2 conditioned media. Metabolic assay and fluorescence imaging showed cellular attachment and proliferation on both LCMs over 14 days. Conclusion The characterisation of the two UK-sourced LCMs showed in vitro biocompatibility and mechanical and ultrastructural properties comparable to the equivalent CM. This in vitro data represents a step forward for the feasibility of adopting LCM for surgical repair of hernias in the UK.
Collapse
|
5
|
Akoh JA. Improving surgical education in East Africa with a standardized hernia training program. Hernia 2021; 25:1369-1370. [PMID: 33683468 DOI: 10.1007/s10029-021-02388-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Accepted: 02/26/2021] [Indexed: 11/26/2022]
Affiliation(s)
- J A Akoh
- University Hospitals Plymouth NHS Trust, Level 07, Derriford Hospital, Plymouth, PL6 8DH, UK.
| |
Collapse
|
6
|
Vaska AI, Munn Z, Nagra S, Barker TH. Hernioplasty using low-cost mesh compared to surgical mesh in low- and middle-income countries: a systematic review protocol. JBI Evid Synth 2020; 18:178-185. [PMID: 31567555 DOI: 10.11124/jbisrir-d-19-00186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
OBJECTIVE This review aims to assess the differences in surgical outcomes between hernioplasty using low-cost mesh and surgical mesh in adults undergoing elective hernioplasty in low- and middle-income countries. INTRODUCTION The use of untreated mosquito netting in inguinal hernioplasty in low- and middle-income countries has been well described in the literature, with two recent limited systematic reviews finding equivalent postoperative surgical outcomes. This comprehensive review, across a wider set of databases and gray literature, will assess a broader set of outcomes including patient and surgeon preference and sterility, report more granular complication outcomes, and include other low-cost mesh alternatives such as resterilized surgical mesh and indigenous products, alongside mosquito net mesh. INCLUSION CRITERIA Adult patients undergoing elective inguinal hernioplasty with mesh in low- and middle-income countries. METHODS Electronic bibliographic databases (PubMed, Embase, Scopus, Web of Science and the Cochrane Library) and gray literature databases and trial registers will be searched for experimental studies, either randomized or quasi-randomized controlled trials, comparing hernioplasty with surgical mesh versus low-cost mesh, published in any language from 2000 to the present. Two independent reviewers will conduct the literature search, screen titles and abstracts, assess full-text studies for inclusion, assess methodological quality using the Cochrane Risk of Bias 2 tool, and extract data using a custom extraction tool. Synthesis will involve pooling for statistical meta-analysis with either a random-effects or fixed-effects model, as appropriate, and where this is not possible, findings will be presented in narrative form. SYSTEMATIC REVIEW REGISTRATION NUMBER PROSPERO CRD42019136028.
Collapse
Affiliation(s)
- Ashish Immanuel Vaska
- Joanna Briggs Institute, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, Australia
- Department of Surgery, Barwon Health, Geelong, Australia
| | - Zachary Munn
- Joanna Briggs Institute, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, Australia
| | - Sonal Nagra
- Department of Surgery, Barwon Health, Geelong, Australia
| | | |
Collapse
|
7
|
Tabiri S, Owusu F, Atindaana Abantanga F, Moten A, Nepogodiev D, Omar O, Bhangu A. Mesh versus suture repair of primary inguinal hernia in Ghana. BJS Open 2019; 3:629-633. [PMID: 31592101 PMCID: PMC6773628 DOI: 10.1002/bjs5.50186] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Accepted: 04/30/2019] [Indexed: 11/30/2022] Open
Abstract
Background Most patients in Ghana undergo suture repair for primary inguinal hernia. Although there is strong evidence from high‐income country settings to indicate superiority of mesh repair for inguinal hernia, the evidence to support the safety and effectiveness of mesh repair in the Ghanaian setting is limited. This study aimed to compare hernia recurrence rates following suture versus mesh repair in Ghana. Methods Men aged 18 years or over presenting with symptomatic, reducible inguinal hernias were included. Over the first 6 months all consecutive patients were enrolled prospectively and underwent a standardized suture repair; an equal number of patients were subsequently enrolled to undergo mesh repair. The primary outcome was hernia recurrence within 3 years of the index operation. Multivariable analysis was adjusted for age and right or left side. Adjusted odds ratios (ORs) with 95 per cent confidence intervals are reported. Results A total of 116 sutured and 116 mesh inguinal hernia repairs were performed. Three years after surgery, follow‐up data were available for 206 of the 232 patients (88·8 per cent). Recurrence occurred significantly more frequently in the suture repair group (23 of 103, 22·3 per cent) than in the mesh group (7 of 103, 6·8 per cent) (P = 0·002). In multivariable analysis, suture repair was independently associated with an increased risk of recurrence (OR 4·51, 95 per cent c.i. 1·76 to 11·52; P = 0·002). Conclusion In Ghana, mesh inguinal hernia repair was associated with reduced 3‐year recurrence compared with sutured repair. Controlled dissemination across Ghana should now be assessed.
Collapse
Affiliation(s)
- S Tabiri
- School of Medicine and Health Sciences University for Development Studies Tamale Ghana.,Tamale Teaching Hospital Tamale Ghana
| | - F Owusu
- St Patrick Hospital Offinso Ghana
| | - F Atindaana Abantanga
- School of Medicine and Health Sciences University for Development Studies Tamale Ghana.,Tamale Teaching Hospital Tamale Ghana
| | - A Moten
- Department of Surgery Temple University Hospital Philadelphia Pennsylvania USA
| | - D Nepogodiev
- National Institute for Health Research Global Health Research Unit on Global Surgery, Institute of Translational Medicine University of Birmingham Birmingham UK
| | - O Omar
- National Institute for Health Research Global Health Research Unit on Global Surgery, Institute of Translational Medicine University of Birmingham Birmingham UK
| | - A Bhangu
- National Institute for Health Research Global Health Research Unit on Global Surgery, Institute of Translational Medicine University of Birmingham Birmingham UK
| |
Collapse
|
8
|
Ahmad MH, Pathak S, Clement KD, Aly EH. Meta-analysis of the use of sterilized mosquito net mesh for inguinal hernia repair in less economically developed countries. BJS Open 2019; 3:429-435. [PMID: 31406956 PMCID: PMC6681152 DOI: 10.1002/bjs5.50147] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 01/18/2019] [Indexed: 11/10/2022] Open
Abstract
Background Inguinal hernias are common in less economically developed countries (LEDCs), and associated with significant morbidity and mortality. Tension-free mesh repair is the standard treatment worldwide. Lack of resources combined with the high cost of commercial synthetic mesh (CSM) have limited its use in LEDCs. Sterilized mosquito net mesh (MNM) has emerged as a low-cost, readily available alternative to CSM. The aim of this systematic review and meta-analysis was to evaluate the safety and efficacy of MNM for the use in hernia repair in LEDCs. Methods A systematic review and data meta-analysis of all published articles from inception to August 2018 was performed. Cochrane Central Register of Controlled Trials, MEDLINE and Embase databases were searched. The primary outcome measure was the overall postoperative complication rate of hernia repair when using MNM. Secondary outcome measures were comparisons between MNM and CSM with regard to overall complication rate, wound infection, chronic pain and haematoma formation. Results A total of nine studies were considered relevant (3 RCTs, 1 non-randomized trial and 5 prospective studies), providing a total cohort of 1085 patients using MNM. The overall complication rate for hernia repair using MNM was 9·3 per cent. There was no significant difference between MNM and CSM regarding the overall postoperative complication rate (odds ratio 0·99, 95 per cent c.i. 0·65 to 1·53; P = 0·98), severe or chronic pain (OR 2·52, 0·36 to 17·42; P = 0·35), infection (OR 0·56, 0·19 to 1·61; P = 0·28) or haematoma (OR 1·05, 0·62 to 1·78; P = 0·86). Conclusion MNM has a low overall postoperative complication rate and is unlikely to be inferior to CSM in terms of safety and efficacy. MNM is a suitable low-cost alternative to CSM in the presence of financial constraint.
Collapse
Affiliation(s)
- M H Ahmad
- University Hospitals of Leicester Leicester UK
| | - S Pathak
- University Hospitals of Leicester Leicester UK
| | - K D Clement
- Queen Elizabeth University Hospital Glasgow UK
| | - E H Aly
- Department of General Surgery, Aberdeen Royal Infirmary Aberdeen UK.,University of Aberdeen Aberdeen UK
| |
Collapse
|
9
|
Katz MG, Price RR, Nunez JM. Local Research Catalyzes National Surgical Planning Comment on "Global Surgery - Informing National Strategies for Scaling Up Surgery in Sub-Saharan Africa". Int J Health Policy Manag 2018; 7:1058-1060. [PMID: 30624880 PMCID: PMC6326645 DOI: 10.15171/ijhpm.2018.78] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 08/04/2018] [Indexed: 01/20/2023] Open
Abstract
In 2015 the Lancet Commission on Global Surgery (LCoGS) argued that surgical care is important to national health systems along with the economic viability of countries. Gajewski and colleagues outlined how the Commission’s blueprint has been implemented in sub-Saharan Africa, including two funded research projects that were integrated into national surgical plans. Here, we outline how the five processes proposed by Gajewski and colleagues are critical to integrate research, policy, and on-the-ground implementation. We also propose that, moving forward, the most pressing adjunct in many low- and middle-income countries (LMICs) may be a better characterization of rural surgical practices through rigorous research along with models that enable lessons to inform national policy.
Collapse
Affiliation(s)
- Micah G Katz
- Center for Global Surgery, University of Utah School of Medicine, Salt Lake City, UT, USA
| | - Raymond R Price
- Center for Global Surgery, University of Utah School of Medicine, Salt Lake City, UT, USA
| | - Jade M Nunez
- Center for Global Surgery, University of Utah School of Medicine, Salt Lake City, UT, USA
| |
Collapse
|
10
|
Tabiri S, Yenli EMT, Gyamfi FE, Jalali A, Nelson RE, Price RR, Katz MG. The use of mesh for inguinal hernia repair in northern Ghana. J Surg Res 2018; 230:137-142. [PMID: 30100030 DOI: 10.1016/j.jss.2018.04.058] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 04/18/2018] [Accepted: 04/24/2018] [Indexed: 10/16/2022]
Abstract
BACKGROUND Despite the recognition that inguinal hernia (IH) repair is cost-effective, repair rates in low- and middle-income countries remain low. Estimated use of mesh in low- and middle-income countries also remains low despite publications about low-cost, noncommercial mesh. The purpose of our study was to assess the current state of IH repair in the northern and transitional zone of Ghana. MATERIALS AND METHODS A retrospective review of surgical case logs of IH repairs from 2013 to 2017 in 41 hospitals was performed. Multivariate logistic regression was used to determine predictors of mesh use. RESULTS Eight thousand eighty male patients underwent IH repair. The range of IH repair in each region was 96 to 295 (overall 123) per 100,000 population. Most cases were performed at district hospitals (84%) and repaired nonurgently (93%) by nonsurgeon physicians (66%). Suture repair was most common (85%) although mesh was used in 15%. The strongest predictor of mesh use was when a surgeon performed surgery (odds ratio [OR] 3.13, P <0.001), followed by surgery being performed in a teaching hospital (OR 2.31, P <0.001). Repair at a regional hospital was a negative predictor of mesh use (OR 0.08, P <0.001) as was the use of general anesthesia (OR 0.40, P = 0.001). CONCLUSIONS Most IH repairs are performed in district hospitals, by nonsurgeon physicians, and without mesh. Rates of repair and the use of mesh are higher than previous estimates in Ghana and Sub-Saharan Africa but not as high as high-income countries.
Collapse
Affiliation(s)
- Stephen Tabiri
- Department Of Surgery, University for Development Studies, School of Medicine and Health Sciences and Tamale Teaching Hospital, Tamale, Ghana
| | - Edwin M T Yenli
- Department Of Surgery, University for Development Studies, School of Medicine and Health Sciences and Tamale Teaching Hospital, Tamale, Ghana
| | - Frank E Gyamfi
- Department Of Surgery, Holy Family Hospital, Berekum, Brong-Ahafo Region, Ghana
| | - Ali Jalali
- Department of Economics Health Economics Core, Population Health Research Foundation, University of Utah, Salt Lake City, Utah
| | - Richard E Nelson
- Department of Internal Medicine, Veterans Affairs, Salt Lake City Health Care System, University of Utah, Salt Lake City, Utah
| | - Raymond R Price
- Department of Surgery, Intermountain Healthcare, Salt Lake City, Utah; Department of Surgery, University Of Utah, Center for Global Surgery, Salt Lake City, Utah
| | - Micah G Katz
- Department of Surgery, University Of Utah, Center for Global Surgery, Salt Lake City, Utah.
| |
Collapse
|
11
|
Abstract
Purpose: The use of prosthetic biomaterials for reconstructing and reinforcing the posterior wall of the inguinal canal reduces the incidence of hernia recurrence. Cost, availability of mesh, and perhaps reluctance to adopt a new technique are factors which prevent widespread practice of hernioplasty in low-resource settings. Use of resterilized mesh significantly reduces the cost of hernioplasty and is safe. Patients and Methods: Sheets of 30 cm × 30 cm polypropylene mesh were cut into 16 cm × 8 cm to produce mesh strips which were repackaged into SELFSEAL® (Medical Action Industries Inc., USA) sterilizing pouches measuring 90 mm × 230 mm and autoclaved. At repair, the strips are shaped to fit the anatomy of the posterior wall of the inguinal canal, a slit created at one end and applied in Lichtenstein repair of inguinal hernias. Patients were monitored for seroma collection and wound infection up to 2 weeks postoperative period. Results: Sixty inguinal hernia repairs were done in 58 patients using the resterilized mesh; two cases being bilateral. One patient (1.7%) had seroma collection at 2 weeks which was aseptically aspirated. We did not record any case of wound infection. Conclusion: The use of sterilized polypropylene mesh for the repair of inguinal hernias is safe and reduced the cost of hernioplasty by reducing the cost of polypropylene mesh. This technique is recommended in low-resource settings.
Collapse
Affiliation(s)
- Isaac Assam Udo
- Department of Surgery, University of Uyo, University of Uyo Teaching Hospital, Uyo, Akwa Ibom State, Nigeria
| | - Ifeanyi A Onwuezobe
- Department of Medical Microbiology, University of Uyo, University of Uyo Teaching Hospital, Uyo, Akwa Ibom State, Nigeria
| | - Kingsley U Umeh
- Department of Surgery, University of Uyo, University of Uyo Teaching Hospital, Uyo, Akwa Ibom State, Nigeria
| |
Collapse
|
12
|
Rouet J, Bwelle G, Cauchy F, Masso-Misse P, Gaujoux S, Dousset B. Polyester mosquito net mesh for inguinal hernia repair: A feasible option in resource limited settings in Cameroon? J Visc Surg 2018; 155:111-116. [DOI: 10.1016/j.jviscsurg.2017.10.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
13
|
Mitura K, Kozieł S. The influence of different sterilization types on mosquito net mesh characteristics in groin hernia repair. Hernia 2018; 22:483-490. [PMID: 29470735 PMCID: PMC5960478 DOI: 10.1007/s10029-018-1756-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Accepted: 02/16/2018] [Indexed: 12/28/2022]
Abstract
Background In low-resource countries, a suture repair is still in common use due to the limited access to commercial mesh implants. The search for less expensive alternatives to the synthetic meshes has led to using mosquito nets. Sterilized mosquito net appears to be a low-cost and commonly available product that closely resembles commercially available meshes. However, the extent to which sterilization alters the structure of mosquito nets is still unknown. The aim of this research was to assess the effects of different sterilization types on physico-mechanical properties of mosquito nets. Materials and methods Nine different polymers were analyzed (six mosquito nets from low-resource countries, one European net, and two commercial meshes). The analyzed parameters included: polymer type, net surface area, fiber diameter, net thickness, mesh weight, pore size, tensile strength, and tear force. The measurements were taken before sterilization, after sterilization at 121 and at 134 °C. Results Sterilization altered net surface and pore size, but did not significantly alter the single fiber diameter, weave of filaments, or net thickness. Steam sterilization did not affect the tensile strength or tear force. Conclusions The reduction of the mosquito net surface area by more than 40% due to sterilization at 121 °C, results in a loss of macroporous structure, turning the mesh into hard, shrunken, non-pliable masses. Sterilization at 134 °C causes some mosquito nets to melt and completely destroys their porous structure. Maximum pressure in the abdominal cavity is higher than the tensile strength and tear force of some locally available mosquito nets; therefore, these nets should not be used.
Collapse
Affiliation(s)
- K Mitura
- General Surgery Department, Siedlce Hospital, ul. Narutowicza 25, 08-110, Siedlce, Poland. .,University of Natural Sciences, Siedlce, Poland.
| | - S Kozieł
- General Surgery Department, Beskid Center of Oncology - Municipal Hospital in Bielsko Biala, Bielsko-Biała, Poland.,University of Bielsko-Biala, Bielsko-Biała, Poland
| |
Collapse
|
14
|
Abstract
INTRODUCTION Worldwide, more than 20 million patients undergo groin hernia repair annually. The many different approaches, treatment indications and a significant array of techniques for groin hernia repair warrant guidelines to standardize care, minimize complications, and improve results. The main goal of these guidelines is to improve patient outcomes, specifically to decrease recurrence rates and reduce chronic pain, the most frequent problems following groin hernia repair. They have been endorsed by all five continental hernia societies, the International Endo Hernia Society and the European Association for Endoscopic Surgery. METHODS An expert group of international surgeons (the HerniaSurge Group) and one anesthesiologist pain expert was formed. The group consisted of members from all continents with specific experience in hernia-related research. Care was taken to include surgeons who perform different types of repair and had preferably performed research on groin hernia surgery. During the Group's first meeting, evidence-based medicine (EBM) training occurred and 166 key questions (KQ) were formulated. EBM rules were followed in complete literature searches (including a complete search by The Dutch Cochrane database) to January 1, 2015 and to July 1, 2015 for level 1 publications. The articles were scored by teams of two or three according to Oxford, SIGN and Grade methodologies. During five 2-day meetings, results were discussed with the working group members leading to 136 statements and 88 recommendations. Recommendations were graded as "strong" (recommendations) or "weak" (suggestions) and by consensus in some cases upgraded. In the Results and summary section below, the term "should" refers to a recommendation. The AGREE II instrument was used to validate the guidelines. An external review was performed by three international experts. They recommended the guidelines with high scores. The risk factors for inguinal hernia (IH) include: family history, previous contra-lateral hernia, male gender, age, abnormal collagen metabolism, prostatectomy, and low body mass index. Peri-operative risk factors for recurrence include poor surgical techniques, low surgical volumes, surgical inexperience and local anesthesia. These should be considered when treating IH patients. IH diagnosis can be confirmed by physical examination alone in the vast majority of patients with appropriate signs and symptoms. Rarely, ultrasound is necessary. Less commonly still, a dynamic MRI or CT scan or herniography may be needed. The EHS classification system is suggested to stratify IH patients for tailored treatment, research and audit. Symptomatic groin hernias should be treated surgically. Asymptomatic or minimally symptomatic male IH patients may be managed with "watchful waiting" since their risk of hernia-related emergencies is low. The majority of these individuals will eventually require surgery; therefore, surgical risks and the watchful waiting strategy should be discussed with patients. Surgical treatment should be tailored to the surgeon's expertise, patient- and hernia-related characteristics and local/national resources. Furthermore, patient health-related, life style and social factors should all influence the shared decision-making process leading up to hernia management. Mesh repair is recommended as first choice, either by an open procedure or a laparo-endoscopic repair technique. One standard repair technique for all groin hernias does not exist. It is recommended that surgeons/surgical services provide both anterior and posterior approach options. Lichtenstein and laparo-endoscopic repair are best evaluated. Many other techniques need further evaluation. Provided that resources and expertise are available, laparo-endoscopic techniques have faster recovery times, lower chronic pain risk and are cost effective. There is discussion concerning laparo-endoscopic management of potential bilateral hernias (occult hernia issue). After patient consent, during TAPP, the contra-lateral side should be inspected. This is not suggested during unilateral TEP repair. After appropriate discussions with patients concerning results tissue repair (first choice is the Shouldice technique) can be offered. Day surgery is recommended for the majority of groin hernia repair provided aftercare is organized. Surgeons should be aware of the intrinsic characteristics of the meshes they use. Use of so-called low-weight mesh may have slight short-term benefits like reduced postoperative pain and shorter convalescence, but are not associated with better longer-term outcomes like recurrence and chronic pain. Mesh selection on weight alone is not recommended. The incidence of erosion seems higher with plug versus flat mesh. It is suggested not to use plug repair techniques. The use of other implants to replace the standard flat mesh in the Lichtenstein technique is currently not recommended. In almost all cases, mesh fixation in TEP is unnecessary. In both TEP and TAPP it is recommended to fix mesh in M3 hernias (large medial) to reduce recurrence risk. Antibiotic prophylaxis in average-risk patients in low-risk environments is not recommended in open surgery. In laparo-endoscopic repair it is never recommended. Local anesthesia in open repair has many advantages, and its use is recommended provided the surgeon is experienced in this technique. General anesthesia is suggested over regional in patients aged 65 and older as it might be associated with fewer complications like myocardial infarction, pneumonia and thromboembolism. Perioperative field blocks and/or subfascial/subcutaneous infiltrations are recommended in all cases of open repair. Patients are recommended to resume normal activities without restrictions as soon as they feel comfortable. Provided expertise is available, it is suggested that women with groin hernias undergo laparo-endoscopic repair in order to decrease the risk of chronic pain and avoid missing a femoral hernia. Watchful waiting is suggested in pregnant women as groin swelling most often consists of self-limited round ligament varicosities. Timely mesh repair by a laparo-endoscopic approach is suggested for femoral hernias provided expertise is available. All complications of groin hernia management are discussed in an extensive chapter on the topic. Overall, the incidence of clinically significant chronic pain is in the 10-12% range, decreasing over time. Debilitating chronic pain affecting normal daily activities or work ranges from 0.5 to 6%. Chronic postoperative inguinal pain (CPIP) is defined as bothersome moderate pain impacting daily activities lasting at least 3 months postoperatively and decreasing over time. CPIP risk factors include: young age, female gender, high preoperative pain, early high postoperative pain, recurrent hernia and open repair. For CPIP the focus should be on nerve recognition in open surgery and, in selected cases, prophylactic pragmatic nerve resection (planned resection is not suggested). It is suggested that CPIP management be performed by multi-disciplinary teams. It is also suggested that CPIP be managed by a combination of pharmacological and interventional measures and, if this is unsuccessful, followed by, in selected cases (triple) neurectomy and (in selected cases) mesh removal. For recurrent hernia after anterior repair, posterior repair is recommended. If recurrence occurs after a posterior repair, an anterior repair is recommended. After a failed anterior and posterior approach, management by a specialist hernia surgeon is recommended. Risk factors for hernia incarceration/strangulation include: female gender, femoral hernia and a history of hospitalization related to groin hernia. It is suggested that treatment of emergencies be tailored according to patient- and hernia-related factors, local expertise and resources. Learning curves vary between different techniques. Probably about 100 supervised laparo-endoscopic repairs are needed to achieve the same results as open mesh surgery like Lichtenstein. It is suggested that case load per surgeon is more important than center volume. It is recommended that minimum requirements be developed to certify individuals as expert hernia surgeon. The same is true for the designation "Hernia Center". From a cost-effectiveness perspective, day-case laparoscopic IH repair with minimal use of disposables is recommended. The development and implementation of national groin hernia registries in every country (or region, in the case of small country populations) is suggested. They should include patient follow-up data and account for local healthcare structures. A dissemination and implementation plan of the guidelines will be developed by global (HerniaSurge), regional (international societies) and local (national chapters) initiatives through internet websites, social media and smartphone apps. An overarching plan to improve access to safe IH surgery in low-resource settings (LRSs) is needed. It is suggested that this plan contains simple guidelines and a sustainability strategy, independent of international aid. It is suggested that in LRSs the focus be on performing high-volume Lichtenstein repair under local anesthesia using low-cost mesh. Three chapters discuss future research, guidelines for general practitioners and guidelines for patients. CONCLUSIONS The HerniaSurge Group has developed these extensive and inclusive guidelines for the management of adult groin hernia patients. It is hoped that they will lead to better outcomes for groin hernia patients wherever they live. More knowledge, better training, national audit and specialization in groin hernia management will standardize care for these patients, lead to more effective and efficient healthcare and provide direction for future research.
Collapse
|
15
|
Surgical Site Infections after Inguinal Hernia Repairs Performed in Low- and Middle-Human Development Index Countries: A Systematic Review. Surg Infect (Larchmt) 2018; 19:11-20. [DOI: 10.1089/sur.2017.154] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
16
|
Todros S, Pavan PG, Pachera P, Pace G, Di Noto V, Natali AN. Interplay between physicochemical and mechanical properties of poly(ethylene terephthalate) meshes for hernia repair. J Appl Polym Sci 2017. [DOI: 10.1002/app.46014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Silvia Todros
- Department of Industrial Engineering; Centre for Mechanics of Biological Materials, University of Padova; Via Venezia 1, Padova PD 35131 Italy
| | - Piero Giovanni Pavan
- Department of Industrial Engineering; Centre for Mechanics of Biological Materials, University of Padova; Via Venezia 1, Padova PD 35131 Italy
| | - Paola Pachera
- Department of Industrial Engineering; Centre for Mechanics of Biological Materials, University of Padova; Via Venezia 1, Padova PD 35131 Italy
| | | | - Vito Di Noto
- Section of Chemistry for Technology, Department of Industrial Engineering; University of Padua; Via Marzolo 1, Padova PD 35131 Italy
| | - Arturo Nicola Natali
- Department of Industrial Engineering; Centre for Mechanics of Biological Materials, University of Padova; Via Venezia 1, Padova PD 35131 Italy
| |
Collapse
|
17
|
Todros S, Pachera P, Pavan PG, Natali AN. Investigation of the Mechanical Behavior of Polyester Meshes for Abdominal Surgery: A Preliminary Study. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0337-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
18
|
A systematic review and meta-analysis of the post-operative adverse effects associated with mosquito net mesh in comparison to commercial hernia mesh for inguinal hernia repair in low income countries. Hernia 2017; 21:397-405. [DOI: 10.1007/s10029-017-1608-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Accepted: 04/04/2017] [Indexed: 10/19/2022]
|
19
|
Uribe-Leitz T, Jaramillo J, Maurer L, Fu R, Esquivel MM, Gawande AA, Haynes AB, Weiser TG. Variability in mortality following caesarean delivery, appendectomy, and groin hernia repair in low-income and middle-income countries: a systematic review and analysis of published data. LANCET GLOBAL HEALTH 2017; 4:e165-74. [PMID: 26916818 DOI: 10.1016/s2214-109x(15)00320-4] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Received: 10/30/2014] [Revised: 11/25/2015] [Accepted: 12/08/2015] [Indexed: 12/13/2022]
Abstract
BACKGROUND Surgical interventions occur at lower rates in resource-poor settings, and complication and death rates following surgery are probably substantial but have not been well quantified. A deeper understanding of outcomes is a crucial step to ensure that high quality accompanies increased global access to surgical care. We aimed to assess surgical mortality following three common surgical procedures--caesarean delivery, appendectomy, and groin (inguinal and femoral) hernia repair--to quantify the potential risks of expanding access without simultaneously addressing issues of quality and safety. METHODS We collected demographic, health, and economic data for 113 countries classified as low income or lower-middle income by the World Bank in 2005. We did a systematic review of Ovid, MEDLINE, PubMed, and Scopus from Jan 1, 2000, to Jan 15, 2015, to identify studies in these countries reporting all-cause mortality following the three commonly undertaken operations. Reports from governmental and other agencies were also identified and included. We modelled surgical mortality rates for countries without reported data using a two-step multiple imputation method. We first used a fully conditional specification (FCS) multiple imputation method to establish complete datasets for all missing variables that we considered potentially predictive of surgical mortality. We then used regression-based predictive mean matching imputation methods, specified within the multiple imputation FCS method, for selected predictors for each operation using the completed dataset to predict mortality rates along with confidence intervals for countries without reported mortality data. To account for variability in data availability, we aggregated results by subregion and estimated surgical mortality rates. FINDINGS From an initial 1302 articles and reports identified, 247 full-text articles met our inclusion criteria, and 124 provided data for surgical mortality for at least one of the three selected operations. We identified 42 countries with mortality data for at least one of the three procedures. Median reported mortality was 7·9 per 1000 operations for caesarean delivery (IQR 2·8-19·9), 2·2 per 1000 operations for appendectomy (0·0-17·2), and 4·9 per 1000 operations for groin hernia (0·0-11·7). Perioperative mortality estimates by subregion ranged from 2·8 (South Asia) to 50·2 (East Asia) per 1000 caesarean deliveries, 2·4 (South Asia) to 54·0 (Central sub-Saharan Africa) per 1000 appendectomies, and 0·3 (Andean Latin America) to 25·5 (Southern sub-Saharan Africa) per 1000 hernia repairs. INTERPRETATION All-cause postoperative mortality rates are exceedingly variable within resource-constrained environments. Efforts to expand surgical access and provision of services must include a strong commitment to improve the safety and quality of care. FUNDING None.
Collapse
Affiliation(s)
| | | | - Lydia Maurer
- Stanford University School of Medicine, Stanford, CA, USA
| | - Rui Fu
- Management Science and Engineering, Stanford University, Stanford, CA, USA
| | | | - Atul A Gawande
- Department of Health Policy and Management, Harvard School of Public Health, Boston, MA, USA; Department of Surgery, Brigham and Women's Hospital, Boston, MA, USA
| | - Alex B Haynes
- Ariadne Labs: a Joint Center for Health System Innovation, Boston, MA, USA; Department of Health Policy and Management, Harvard School of Public Health, Boston, MA, USA; Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | | |
Collapse
|
20
|
Raykar NP, Yorlets RR, Liu C, Goldman R, Greenberg SLM, Kotagal M, Farmer PE, Meara JG, Roy N, Gillies RD. The How Project: understanding contextual challenges to global surgical care provision in low-resource settings. BMJ Glob Health 2016; 1:e000075. [PMID: 28588976 PMCID: PMC5321373 DOI: 10.1136/bmjgh-2016-000075] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 10/14/2016] [Accepted: 11/11/2016] [Indexed: 02/02/2023] Open
Abstract
INTRODUCTION 5 billion people around the world do not have access to safe, affordable, timely surgical care. This series of qualitative interviews was launched by The Lancet Commission on Global Surgery (LCoGS) with the aim of understanding the contextual challenges-the specific circumstances-faced by surgical care providers in low-resource settings who care for impoverished patients, and how those providers overcome these challenges. METHODS From January 2014 to February 2015, 20 LCoGS collaborators conducted semistructured interviews with 148 surgical providers in low-resource settings in 21 countries. Stratified purposive sampling was used to include both rural and urban providers, and reputational case selection identified individuals. Interviewers were trained with an implementation manual. Following immersion into de-identified texts from completed interviews, topical coding and further analysis of coded texts was completed by an independent analyst with periodic validation from a second analyst. RESULTS Providers described substantial financial, geographic and cultural barriers to patient access. Rural surgical teams reported a lack of a trained workforce and insufficient infrastructure, equipment, supplies and banked blood. Urban providers face overcrowding, exacerbated by minimal clinical and administrative support, and limited interhospital care coordination. Many providers across contexts identified national health policies that do not reflect the realities of resource-poor settings. Some findings were region-specific, such as weak patient-provider relationships and unreliable supply chains. In all settings, surgical teams have created workarounds to deliver care despite the challenges. DISCUSSION While some differences exist between countries, the barriers to safe surgery and anaesthesia are overall consistent and resource-dependent. Efforts to advance and expand global surgery must address these commonalities, while local policymakers can tailor responses to key contextual differences.
Collapse
Affiliation(s)
- Nakul P Raykar
- Program in Global Surgery and Social Change, Harvard Medical School, Boston, Massachusetts, USA
- Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | | | - Charles Liu
- Program in Global Surgery and Social Change, Harvard Medical School, Boston, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Roberta Goldman
- Alpert Medical School, Brown University, Providence, Rhode Island, USA
- Harvard T. H. Chan School of Public Health, Boston, Massachusetts, USA
| | - Sarah L M Greenberg
- Program in Global Surgery and Social Change, Harvard Medical School, Boston, Massachusetts, USA
- Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Meera Kotagal
- Program in Global Surgery and Social Change, Harvard Medical School, Boston, Massachusetts, USA
- University of Washington, Seattle, Washington, USA
| | - Paul E Farmer
- Program in Global Surgery and Social Change, Harvard Medical School, Boston, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
- Partners in Health, Boston, Massachusetts,USA
- Brigham and Women's Hospital, Division of Global Health Equity, Boston, Massachusetts, USA
| | - John G Meara
- Program in Global Surgery and Social Change, Harvard Medical School, Boston, Massachusetts, USA
- Boston Children's Hospital, Boston, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Nobhojit Roy
- BARC Hospital (Government of India), HBNI University, Mumbai, Maharashtra, India
- Health Systems and Policy Research Group, Department of Public Health Sciences, Karolinska Institutet, Stockholm, Sweden
| | - Rowan D Gillies
- Program in Global Surgery and Social Change, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
21
|
In-vitro examination of the biocompatibility of fibroblast cell lines on alloplastic meshes and sterilized polyester mosquito mesh. Hernia 2016; 21:407-416. [DOI: 10.1007/s10029-016-1550-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Accepted: 11/12/2016] [Indexed: 11/26/2022]
|
22
|
Löfgren J, Nordin P, Ibingira C, Matovu A, Galiwango E, Wladis A. A Randomized Trial of Low-Cost Mesh in Groin Hernia Repair. N Engl J Med 2016; 374:146-53. [PMID: 26760085 DOI: 10.1056/nejmoa1505126] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND The most effective method for repair of a groin hernia involves the use of a synthetic mesh, but this type of mesh is unaffordable for many patients in low- and middle-income countries. Sterilized mosquito meshes have been used as a lower-cost alternative but have not been rigorously studied. METHODS We performed a double-blind, randomized, controlled trial comparing low-cost mesh with commercial mesh (both lightweight) for the repair of a groin hernia in adult men in eastern Uganda who had primary, unilateral, reducible groin hernias. Surgery was performed by four qualified surgeons. The primary outcomes were hernia recurrence at 1 year and postoperative complications. RESULTS A total of 302 patients were included in the study. The follow-up rate was 97.3% after 2 weeks and 95.6% after 1 year. Hernia recurred in 1 patient (0.7%) assigned to the low-cost mesh and in no patients assigned to the commercial mesh (absolute risk difference, 0.7 percentage points; 95% confidence interval [CI], -1.2 to 2.6; P=1.0). Postoperative complications occurred in 44 patients (30.8%) assigned to the low-cost mesh and in 44 patients (29.7%) assigned to the commercial mesh (absolute risk difference, 1.0 percentage point; 95% CI, -9.5 to 11.6; P=1.0). CONCLUSIONS Rates of hernia recurrence and postoperative complications did not differ significantly between men undergoing hernia repair with low-cost mesh and those undergoing hernia repair with commercial mesh. (Funded by the Swedish Research Council and others; Current Controlled Trials number, ISRCTN20596933.).
Collapse
Affiliation(s)
- Jenny Löfgren
- From the Department of Public Health and Clinical Medicine, Unit of Research, Education, and Development, Östersund, Umeå University, Umeå (J.L., P.N.), and the Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm (A.W.) - both in Sweden; and the Schools of Biomedical Sciences (C.I.) and Medicine (A.M.), Makerere University, and the Mulago National Referral Hospital (C.I.), Kampala, and the School of Public Health, Iganga-Mayuge Health and Demographic Surveillance Site, Iganga (E.G.) - all in Uganda
| | | | | | | | | | | |
Collapse
|
23
|
Sharma M, Sharma DB, Chandrakar SK, Sharma D. Histopathological Comparison of Mosquito Net with Polypropylene Mesh for Hernia Repair: An Experimental Study in Rats. Indian J Surg 2016; 77:511-4. [PMID: 26730055 DOI: 10.1007/s12262-013-0904-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2012] [Accepted: 03/18/2013] [Indexed: 11/29/2022] Open
Abstract
Use of mosquito net, in place of polypropylene mesh, had been reported for tension-free hernia repair, as a better cost-effective option. This experimental histopathological study was performed in rats to find out the tissue response and the foreign body reaction and its comparison between commercial polypropylene mesh and the sterilized mosquito net. This experimental study was conducted in the Department of Surgery, Government NSCB, Medical College, Jabalpur (Madhya Pradesh), India. It was carried out in 40 albino rats. A 1.5 × 0.5-cm hernial defect was created by excising full-thickness abdominal wall muscle. All rats underwent on-lay mesh repair of hernial defect (polypropylene mesh, n = 20; mosquito net, n = 20). Half of rats in each group were sacrificed on day 14, and the other half, on day 90. Sections of containing mesh were examined histopathologically for inflammatory infiltrate, giant cells, and collagen deposition. Mosquito net group showed significantly greater number of giant cells and inflammatory cells at 14 and 90 days (p < 0.0001, p < 0.001, p < 0.05, and p < 0.001, respectively), as compared to polypropylene group. Grades of collagen fiber deposition were almost equal in both groups, both at 14 and 90 days (p > 0.05 and p > 0.05, respectively). Results of mosquito net are comparable to conventional polypropylene mesh. In a setup, where cost-effectiveness is of primary importance, use of mosquito net for tension-free hernia repair can be an acceptable alternative as proven histologically, to commercially available polypropylene mesh.
Collapse
Affiliation(s)
- Mukesh Sharma
- Department of Surgery, Government NSCB Medical College, Jabalpur, 482 003 Madhya Pradesh India
| | - Deepti Bala Sharma
- Department of Surgery, Government NSCB Medical College, Jabalpur, 482 003 Madhya Pradesh India ; R-3, Doctors Colony, Medical College, Jabalpur, Madhya Pradesh India
| | - Shiv Kumar Chandrakar
- Department of Pathology, Government NSCB Medical College, Jabalpur, 482 003 Madhya Pradesh India
| | - Dhananjaya Sharma
- Department of Surgery, Government NSCB Medical College, Jabalpur, 482 003 Madhya Pradesh India
| |
Collapse
|
24
|
The Usefulness of International Cooperation in the Repair of Inguinal Hernias in Sub-Saharan Africa. World J Surg 2015. [DOI: 10.1007/s00268-015-3161-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
25
|
Kozieł S, Mitura K, Papaj P, Lorenc Z. Tension-Free Mosquito Net Mesh Inguinal Hernioplasty - an Alternative Exclusively for the Third World? POLISH JOURNAL OF SURGERY 2015; 87:102-7. [PMID: 26146103 DOI: 10.1515/pjs-2015-0027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2014] [Indexed: 11/15/2022]
|
26
|
Oribabor FO, Amao OA, Akanni SO, Fatidinu SO. The use of nontreated mosquito-net mesh cloth for a tension free inguinal hernia repair: our experience. Niger J Surg 2015; 21:48-51. [PMID: 25838767 PMCID: PMC4382643 DOI: 10.4103/1117-6806.152726] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Introduction: The prohibitive costs and scarcity of the imported prosthetic mesh for hernioplasty, has prevented its widespread use in most developing countries. We then set out to ascertain the outcome, complications (undue pain, wound infection, recurrence, and mesh extrusion) and cost implications in the use of a nontreated mosquito-net for inguinal hernioplasty. Materials and Methods: A prospective study of all consecutive adult patients with uncomplicated inguinal hernia who were admitted for open herniorrhaphy between January 2012 and December, 2013 at the Federal Medical Centre, Ido – Ekiti, South West, Nigeria. A sheet of the nontreated mosquito-net mesh 10 cm Χ 8 cm, autoclaved, a day prior to surgery was used for each patient's hernia repair. The operation sites were exposed and examined 3rd and 6th postoperative days. Findings were documented for analysis. Result: A total of 130 adult patients were recruited for this study of which 115 of the patients were males and 15 were females. Forty-four (41.53%) had inguinal hernia and 76 (58.46%) of them had inguinoscrotal hernia. They all had successful repair and were followed-up for complications for a period of 6 weeks to 6 months at the surgical out-patient department. Conclusion: Locally-sourced and autoclaved mosquito-net mesh is an effective alternative for hernioplasty especially in situations where commercial mesh is not readily available or affordable.
Collapse
Affiliation(s)
- Felix O Oribabor
- Department of Surgery, Federal Medical Centre, Ido Ekiti, Ekiti, Nigeria
| | - Oluwasegun A Amao
- Department of General Surgery Division, Federal Medical Centre, Ido Ekiti, Ekiti, Nigeria
| | - Saheed O Akanni
- Department of General Surgery Division, Federal Medical Centre, Ido Ekiti, Ekiti, Nigeria
| | - Samuel O Fatidinu
- Department of General Surgery Division, Federal Medical Centre, Ido Ekiti, Ekiti, Nigeria
| |
Collapse
|
27
|
Ambroziak A, Szepietowska K, Lubowiecka I. Mechanical properties of mosquito nets in the context of hernia repair. Comput Methods Biomech Biomed Engin 2015; 19:286-296. [PMID: 25756655 DOI: 10.1080/10255842.2015.1016004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The paper deals with issue of applying mosquito nets as implants in hernia repair, which have already been used in resource-poor developing countries. Uniaxial tensile tests have been conducted on polyester mosquito meshes in two orthogonal directions. Non-linear elastic constitutive laws parameters have been identified to be applied in dense net material models. Mechanical performance of tested mosquito nets has been compared with properties of commercial implants used in treatment of hernia and with properties of human tissue. This study contributes to mechanical knowledge of hernia repair issue by investigation of cheaper alternative to commercial implants.
Collapse
Affiliation(s)
- Andrzej Ambroziak
- a Department of Structural Mechanics , Faculty of Civil and Environmental Engineering, Gdansk University of Technology , Narutowicza 11/12, 80 - 233 Gdańsk , Poland
| | - Katarzyna Szepietowska
- a Department of Structural Mechanics , Faculty of Civil and Environmental Engineering, Gdansk University of Technology , Narutowicza 11/12, 80 - 233 Gdańsk , Poland
| | - Izabela Lubowiecka
- a Department of Structural Mechanics , Faculty of Civil and Environmental Engineering, Gdansk University of Technology , Narutowicza 11/12, 80 - 233 Gdańsk , Poland
| |
Collapse
|
28
|
Oppong FC. Innovation in income-poor environments. Br J Surg 2015; 102:e102-7. [DOI: 10.1002/bjs.9712] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Accepted: 10/10/2014] [Indexed: 12/11/2022]
Abstract
Abstract
Background
At the core of surgical development in any economic environment lies innovation. Innovation in high-income countries (HICs) often derives from research, whereas innovation in low- and middle-income countries (LMICs) may be spontaneous owing to a desperate drive to meet a local need. The local needs are substantial because of the unequal access to healthcare in LMICs.
Methods
The experience of the author in working in LMICs through Operation Hernia, a medical charity, provides a backdrop for this review. Other published innovative devices and models are discussed.
Results
Innovation in income-poor countries has provided cost-effective but efficient solutions to local health needs. Some innovations have been enhanced and adopted worldwide.
Conclusion
HICs can learn more from innovative strategies adopted in LMICs.
Collapse
Affiliation(s)
- F C Oppong
- Colorectal Unit, Derriford Hospital, Plymouth PL6 8DH, UK
| |
Collapse
|
29
|
Abstract
Short-term medical service trips (MSTs) aim to address unmet health care needs of low- and middle-income countries. The lack of critically reviewed empirical evidence of activities and outcomes is a concern. Developing evidence-based recommendations for health care delivery requires systematic research review. I focused on MST publications with empirical results. Searches in May 2013 identified 67 studies published since 1993, only 6% of the published articles on the topic in the past 20 years. Nearly 80% reported on surgical trips. Although the MST field is growing, its medical literature lags behind, with nearly all of the scholarly publications lacking significant data collection. By incorporating data collection into service trips, groups can validate practices and provide information about areas needing improvement.
Collapse
Affiliation(s)
- Kevin J Sykes
- Kevin J. Sykes is with the Department of Health Policy and Management in the School of Medicine at the University of Kansas Medical Center, Kansas City
| |
Collapse
|
30
|
Assessing the impact of short-term surgical education on practice: a retrospective study of the introduction of mesh for inguinal hernia repair in sub-Saharan Africa. Hernia 2014; 18:549-56. [DOI: 10.1007/s10029-014-1255-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Accepted: 04/10/2014] [Indexed: 12/31/2022]
|
31
|
Sanders DL, Kingsnorth AN. Prosthetic mesh materials used in hernia surgery. Expert Rev Med Devices 2014; 9:159-79. [DOI: 10.1586/erd.11.65] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
32
|
An estimate of hernia prevalence in Sierra Leone from a nationwide community survey. Hernia 2013; 18:297-303. [PMID: 24241327 DOI: 10.1007/s10029-013-1179-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2013] [Accepted: 10/31/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE A large number of unrepaired inguinal hernias is expected in sub-Saharan Africa where late presentation often results in incarceration, strangulation, or giant scrotal hernias. However, no representative population-based data are available to quantify the prevalence of hernias. We present data on groin masses in Sierra Leone to estimate prevalence, barriers to care, and associated disability. METHODS A cluster randomized, cross-sectional household survey of 75 clusters of 25 households with 2 respondents each was designed to calculate the prevalence of and disability caused by groin hernias in Sierra Leone using a verbal head-to-toe examination. Barriers to hernia repairs were assessed by asking participants the main reason for delay in surgical care. RESULTS Information was obtained from 3,645 respondents in 1,843 households, of which 1,669 (46%) were male and included in the study. In total, 117 males or 7.01% (95% CI 5.64-8.38) reported a soft or reducible swelling likely representing a hernia with four men having two masses. Of the 93.2% who indicated the need for health care, only 22.2% underwent a procedure, citing limited funds (59.0%) as the major barrier to care. On disability assessment, 20.2% were not able to work secondary to the groin swelling. CONCLUSIONS The results indicate groin masses represent a major burden for the male population in Sierra Leone. Improving access to surgical care for adult patients with hernias and early intervention for children will be vital to address the burden of disease and prevent complications or limitations of daily activity.
Collapse
|
33
|
Sanders DL, Kingsnorth AN, Moate R, Steer JA. An in vitro study assessing the infection risk of low-cost polyethylene mosquito net compared with commercial hernia prosthetics. J Surg Res 2013; 183:e31-7. [DOI: 10.1016/j.jss.2013.01.047] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2012] [Revised: 12/27/2012] [Accepted: 01/24/2013] [Indexed: 10/27/2022]
|
34
|
Gil J, Rodríguez JM, Hernández Q, Gil E, Balsalobre MD, González M, Torregrosa N, Verdú T, Alcaráz M, Parrilla P. Do hernia operations in african international cooperation programmes provide good quality? World J Surg 2013; 36:2795-801. [PMID: 22976790 DOI: 10.1007/s00268-012-1768-9] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Hernia is especially prevalent in developing countries where the population is obliged to undertake strenuous work in order to survive, and International Cooperation Programmes are helping to solve this problem. However, the quality of surgical interventions is unknown. The objective of the present study was to evaluate the quality of hernia repair processes carried out by the Surgical Solidarity Charity in Central African States. MATERIALS AND METHODS A total of 524 cases of inguinal hernia repair carried out in Cameroon and Mali during 2005 to 2009 were compared with 386 cases treated in a Multicentre Spanish Study (2003). General data (clinical, demographic, etc.), type of surgery, complications, and effectiveness and efficiency indicators were collected. RESULTS Preoperative studies in the Spanish group were greater in number than in the African group. The use of local anesthesia was similar. Antibiotic prophylaxis was higher in the African group (100% to 75.4%). The use of mesh was similar. The incidence of hematomas was higher in the Spanish group (11.61% to 4.61%), but the incidence of infection of the wound and of hernia recurrence was similar, although follow-up was only carried out in 20.97% in the African group (70% in the Spanish group). Hospital stay of more than 24 h was higher in the Spanish group. CONCLUSIONS The standard quality of surgery for the treatment of hernia in developing countries with few instrumental means, and in sub-optimal surgical conditions is similar to that provided in Spain.
Collapse
Affiliation(s)
- J Gil
- General and Gastrointestinal Surgery Service, Virgen de la Arrixaca University Hospital, El Palmar, Murcia, Spain.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
35
|
Mosquito Net Mesh for Abdominal Wall Hernioplasty: A Comparison of Material Characteristics with Commercial Prosthetics. World J Surg 2013; 37:737-45. [DOI: 10.1007/s00268-012-1900-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
36
|
Beard JH, Oresanya LB, Ohene-Yeboah M, Dicker RA, Harris HW. Characterizing the Global Burden of Surgical Disease: A Method to Estimate Inguinal Hernia Epidemiology in Ghana. World J Surg 2012; 37:498-503. [DOI: 10.1007/s00268-012-1864-x] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
37
|
|
38
|
The use of sterilized mosquito nets for hernioplasty: a systematic review. Hernia 2012; 16:621-5. [DOI: 10.1007/s10029-012-0973-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2011] [Accepted: 07/12/2012] [Indexed: 10/28/2022]
|
39
|
Abstract
BACKGROUND We report through a retrospective analysis our experience of providing surgical care and on-the-job training through mobile surgical missions in southern Sudan during the post conflict period between 2005 and 2009. METHODS Three surgical teams conducted 23 missions in 5 primary health care centers sited in remote areas of southern Sudan. King's analytical framework for surgical care in developing countries is adopted to evaluate the appropriateness of services rendered. Exact logistic regression was performed to investigate differences in mortality depending on the level of training of the operators and anesthetists. RESULTS A total of 1,543 patients were operated on during a 5 year period, of which 9 (0.58%) died. The majority of operations were elective surgery cases (which may help contextualize the exceptionally low mortality rate). Several adaptations to surgical techniques adopted and preoperative and postoperative care were required. There were no statistically significant differences in mortality between operations performed by expatriate specialists and local midlevel providers with lower level training. CONCLUSIONS This experience in southern Sudan demonstrates that surgical services can be established utilizing simple facilities and equipment and employing local personnel selected and trained on-the-job by teams composed of a consultant surgeon, anesthetist, and scrub nurse. Delegation of tasks relating to anesthesia and surgery to midlevel health providers is an appropriate approach in developing countries facing shortage and maldistribution of more qualified health workers.
Collapse
|
40
|
Randomized controlled multicenter international clinical trial of self-gripping Parietex™ ProGrip™ polyester mesh versus lightweight polypropylene mesh in open inguinal hernia repair: interim results at 3 months. Hernia 2012; 16:287-94. [PMID: 22453675 DOI: 10.1007/s10029-012-0900-y] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2011] [Accepted: 01/13/2012] [Indexed: 11/27/2022]
Abstract
PURPOSE To compare clinical outcomes following sutureless Parietex™ ProGrip™ mesh repair to traditional Lichtenstein repair with lightweight polypropylene mesh secured with sutures. METHODS This is a 3-month interim report of a 1-year multicenter international study. Three hundred and two patients were randomized; 153 were treated with Lichtenstein repair (L group) and 149 with Parietex™ ProGrip™ precut mesh (P group) with or without fixation. The primary outcome measure was postoperative pain using the visual analog scale (VAS, 0-150 mm); other outcomes were assessed prior to surgery and up to 3 months postoperatively. RESULTS Compared to baseline, pain score was lower in the P group at discharge (-10%) and at 7 days (-13%), while pain increased in the L group at discharge (+39%) and at 7 days (+21%). The difference between groups was significant at both time points (P = 0.007 and P = 0.039, respectively). In the P group, patients without fixation suffered less pain compared to those with single-suture fixation (1 month: -20.9 vs. -6.15%, P = 0.02; 3 months: -24.3 vs. -7.7%, P = 0.01). The infection rate was significantly lower in the P group during the 3-month follow-up (2.0 vs. 7.2%, P = 0.032). Surgery duration was significantly shorter in the P group (32.4 vs. 39.1 min; P < 0.001). No recurrence was observed at 3 months in both groups. CONCLUSIONS Surgery duration, early postoperative, pain and infection rates were significantly reduced with self-gripping polyester mesh compared to Lichtenstein repair with polypropylene mesh. The use of fixation increased postoperative pain in the P group. The absence of early recurrence highlights the gripping efficiency effect.
Collapse
|
41
|
Prospective randomized controlled study using polyethylene mesh for inguinal hernia meshplasty as a safe and cost-effective alternative to polypropylene mesh. Updates Surg 2011; 64:37-42. [DOI: 10.1007/s13304-011-0103-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2011] [Accepted: 08/02/2011] [Indexed: 10/17/2022]
|
42
|
Coda A, Lamberti R, Martorana S. Classification of prosthetics used in hernia repair based on weight and biomaterial. Hernia 2011; 16:9-20. [PMID: 21837484 DOI: 10.1007/s10029-011-0868-z] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2010] [Accepted: 07/22/2011] [Indexed: 12/12/2022]
Abstract
PURPOSE The aim of this study was to classify the polymeric prosthetics used for hernia repair based on biomaterial composition and weight in an effort to clarify to surgeons what kinds of material they are dealing with and to provide a standardized system of categorization. MATERIALS AND METHODS An intensive research effort was carried out on prosthetics that are commercially available worldwide. We conducted a search of the medical literature and companies' websites to find the weights and thicknesses of commercially available prosthetics. Where these data were lacking, we contacted manufacturers directly in order to render the research more complete. A total of 166 products were considered for classification based on biomaterial properties. Among these, a homogeneous group of 80 polypropylene monofilament knitted or woven prosthetics was selected for classification based on weight. Weights were provided for 70 prosthetics (87%), and both the weight and thickness was provided for 40 prosthetics (50%). RESULTS Classification based on weight: Ultra-light <35 g/m(2), Light ≥35 < 70 g/m(2), Standard ≥70 < 140 g/m(2), Heavy ≥140 g/m(2). Classification based on biomaterial composition: simple (prosthetics made of one pure biomaterial); composite (prosthetics made of two or more different layers); combined (prosthetics made of two materials knitted or woven together); and biologic. CONCLUSION Weight and biomaterial classifications were proposed after an extensive analysis of commercially available prosthetics. The need for a common terminology is important to avoid misunderstandings among clinicians and technicians.
Collapse
Affiliation(s)
- A Coda
- Surgical Department, Clinica Cellini, Turin, Italy.
| | | | | |
Collapse
|
43
|
Safety and Sterilization of Mosquito Net Mesh for Humanitarian Inguinal Hernioplasty. World J Surg 2011; 35:1957-60. [DOI: 10.1007/s00268-011-1176-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
44
|
Low-cost mesh for inguinal hernia repair in resource-limited settings. Hernia 2011; 15:485-9. [DOI: 10.1007/s10029-011-0827-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2011] [Accepted: 04/22/2011] [Indexed: 10/18/2022]
|
45
|
Jacquetin B. [Introduction to the diagnosis and management of adult female urinary incontinence]. J Gynecol Obstet Hum Reprod 2009; 38:S135-S137. [PMID: 20141911 DOI: 10.1016/s0368-2315(09)73571-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
46
|
Corrections to 'The use of sterilised polyester mosquito net mesh for inguinal hernia repair in Ghana'. Hernia 2009; 13:669. [PMID: 19809861 DOI: 10.1007/s10029-009-0565-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2009] [Accepted: 09/18/2009] [Indexed: 10/20/2022]
|
47
|
|
48
|
Some aspects of the epidemiology of external Hernias in Kumasi, Ghana. Hernia 2009; 13:529-32. [DOI: 10.1007/s10029-009-0491-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2008] [Accepted: 03/01/2009] [Indexed: 10/21/2022]
|