1
|
Picciariello A, Annicchiarico A, Gallo G, Dezi A, Grossi U. Evaluation of the da Vinci single-port system in colorectal cancer surgery: a scoping review. Updates Surg 2024:10.1007/s13304-024-02014-y. [PMID: 39369142 DOI: 10.1007/s13304-024-02014-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2024] [Accepted: 09/25/2024] [Indexed: 10/07/2024]
Abstract
Minimally invasive surgery for the treatment of colon and rectal cancer has gained popularity due to its association with reduced postoperative pain, shorter hospital stays, and quicker recovery. The Da Vinci Single-Port (SP) System combines single-port laparoscopy with robotic assistance. This scoping review aims to evaluate the safety and short-term postoperative outcomes of utilizing the Da Vinci SP platform in colorectal cancer surgery. A scoping review was conducted adhering to the PRISMA-ScR guidelines. Data were collected from PubMed, Embase, and the Web of Science Library as of December 22, 2023. Studies were screened and selected based on predefined criteria, focusing on the application of the SP robotic system in colorectal procedures. Data extraction included demographics, surgical details, intraoperative and postoperative outcomes. A narrative summary of the results was provided due to the heterogeneity in study designs. From an initial 2312 articles, 22 studies were selected for analysis, encompassing 465 patients undergoing robotic SP colorectal surgeries. Of these, 384 (82.6%) had a cancer diagnosis. The median age was 65 years, with approximately 60% being male. The median operative time was 225 min, with docking times averaging 12-20 min. Conversion to multi-port laparoscopy occurred in 4.2% of cases, with no conversions to open surgery. Mean intraoperative blood loss ranged from 50 to 150 ml. The mean number of lymph nodes retrieved ranged from 15 to 28. A diverting ileostomy was constructed in 20.3% of patients. Median times to flatus and soft diet were 2.5 and 3 days, respectively, with hospital stays ranging from 3 to 11 days. Perioperative complications occurred in 15.1% of patients, including wound infections (5.1%), anastomotic leakage (3.7%), and postoperative ileus (2.8%). Negative margin status (R0 resection) was achieved in 95% of cases. The Da Vinci SP robotic platform demonstrates promising safety and effectiveness in colorectal cancer surgery. It achieves high rates of successful oncological resection, adequate lymph node retrieval, and minimal intraoperative blood loss. Postoperative outcomes indicate quicker recovery times and manageable complication rates. However, longer follow-up studies are necessary to fully assess recurrence rates and long-term survival benefits associated with this innovative surgical approach.
Collapse
Affiliation(s)
| | - Alfredo Annicchiarico
- Department of Medicine and Surgery, University of Parma, Parma, Italy
- Department of General Surgery, Vaio Hospital, Fidenza, Italy
| | - Gaetano Gallo
- Department of Surgery, La Sapienza" University of Rome, Rome, Italy
| | - Agnese Dezi
- Department of Precision and Regenerative Medicine and Ionian Area, University Aldo Moro of Bari, Piazza G. Cesare, 11, 70124, Bari, Italy.
| | - Ugo Grossi
- Department of Surgery, Oncology and Gastroenterology-DiSCOG, University of Padova, Padua, Italy
| |
Collapse
|
2
|
Sarin A, Barnes KE, Shui AM, Nakamura Y, Hoffman DB, Romero-Hernandez F, Chern H. Initial Experience With Single-Port Robotic Right Colectomies: Results of an Investigator-Initiated Investigational Device Exemption Study Using a Novel Single-Port Robotic Platform. Dis Colon Rectum 2024; 67:e1600-e1606. [PMID: 39250792 DOI: 10.1097/dcr.0000000000003352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/11/2024]
Abstract
BACKGROUND Minimally invasive surgical techniques have been widely adopted in colorectal surgery. New technological breakthroughs have led to even less invasive alternatives like single-port surgery, but this has been hindered by technical challenges such as the collision of robotic arms within a limited space. The Intuitive da Vinci Single-Port robotic platform is a novel system that overcomes some of these challenges. IMPACT OF INNOVATION This study aimed to assess the safety and feasibility of the Intuitive da Vinci Single-Port robotic platform in right segmental colectomies among adult patients. These findings may set the stage for more widespread use of single-port robotic surgery. TECHNOLOGY, MATERIALS, AND METHODS The Intuitive da Vinci Single-Port robot is a system designed specifically for single-port robotic surgery. This platform enables flexible port location and efficient internal and external range of motion using a single C-shaped arm. In the present study, right colectomies were performed in adult patients using this platform between May 2022 and November 2022, and they were compared to right colectomies in adult patients performed using the standard multiport platform between January 2019 and December 2022. The main outcome measure was safety and quality event rates. PRELIMINARY RESULTS Of 30 patients, 16.7% of patients (n = 5) underwent single-port robotic right colectomy and 83.3% (n = 25) underwent multiport right colectomy. In the single-port group, 40% of patients (n = 2) developed a safety/quality event (postoperative portal vein thrombosis and excessive postoperative pain). In the multiport group, 32% of patients (n = 8) developed 1 safety/quality event and 8% (n = 2) had more than 1 event. CONCLUSIONS AND FUTURE DIRECTIONS This preliminary study, one of the first Food and Drug Administration-approved, investigator-initiated uses of this platform in colorectal surgeries, shows that this platform is a safe and feasible option for right colectomies. On preliminary evaluation, it appears comparable in terms of relevant safety/quality events to the multiport platform. CLINICAL TRIAL REGISTRATION Clinicaltrials.gov NCT05321134.
Collapse
Affiliation(s)
- Ankit Sarin
- Department of Surgery, University of California, Davis, California
| | - Katherine E Barnes
- School of Medicine, University of California, San Francisco, San Francisco, California
| | - Amy M Shui
- Department of Epidemiology and Biostatistics, University of California, San Francisco, San Francisco, California
| | - Yukino Nakamura
- Department of Surgery, University of California, San Francisco, San Francisco, California
| | - Daniel B Hoffman
- Department of Surgery, University of California, San Francisco, San Francisco, California
| | | | - Hueylan Chern
- Department of Surgery, University of California, San Francisco, San Francisco, California
| |
Collapse
|
3
|
Celotto F, Ramacciotti N, Mangano A, Danieli G, Pinto F, Lopez P, Ducas A, Cassiani J, Morelli L, Spolverato G, Bianco FM. Da Vinci single-port robotic system current application and future perspective in general surgery: A scoping review. Surg Endosc 2024; 38:4814-4830. [PMID: 39110221 PMCID: PMC11362253 DOI: 10.1007/s00464-024-11126-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Accepted: 07/27/2024] [Indexed: 09/01/2024]
Abstract
BACKGROUND The da Vinci Single-Port Robot System (DVSP) allows three robotic instruments and an articulated scope to be inserted through a single small incision. It received FDA approval in 2014 and was first introduced in 2018. The aim of this new system was to overcome the limitations of single-incision laparoscopic and robotic surgery. Since then, it has been approved for use only for urologic and transoral surgeries in some countries. It has been used as part of experimental protocols in general surgery. OBJECTIVE By obtaining the CE mark at the end of January 2024, DVSP will soon enter the European market. This review aims to comprehensively describe the applications of DVSP in general surgery. DESIGN A search of PubMed, Embase, and Ebsco databases up to March 2024 was conducted, with registration in PROSPERO (CRD42024536430), following the preferred reporting items for Systematic reviews and Meta-analyses for scoping review (PRISMA-Scr) guidelines. All the studies about the use of DVSP in general surgery were included. RESULTS Fifty-six studies were included. The following surgical areas of use were identified: transabdominal and transanal colorectal, cholecystectomy, abdominal wall repair, upper gastroesophageal tract, liver, pancreas, breast, and thyroid surgery. The reported surgical and short-term outcomes are promising; a wide range of procedures have been performed safely. Some groups have found advantages, such as faster discharge, shorter operative time, and less postoperative pain compared to multiport robotic surgery. CONCLUSION Five years after its initial clinical applications, the use of the DVSP in general surgery procedures has demonstrated feasibility and safety. Hernia repair, cholecystectomy, and colorectal surgery emerge as the most frequently conducted interventions with this robotic system. Nevertheless, there is anticipation for further studies with larger sample sizes and extended follow-up periods to provide more comprehensive insights and data on the long-term outcomes, including the incidence of incisional hernia.
Collapse
Affiliation(s)
- Francesco Celotto
- Department of Surgical, Oncological and Gastroenterological Sciences, University of Padova, Padova, Italy.
| | - Niccolò Ramacciotti
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Alberto Mangano
- Division of General, Minimally Invasive, and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Giacomo Danieli
- Unit of Biostatistics, Epidemiology and Public Health (UBEP), Department of Cardio-Thoraco-Vascular Sciences and Public Health, University of Padua, Padova, Italy
| | - Federico Pinto
- Division of General, Minimally Invasive, and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Paula Lopez
- Division of General, Minimally Invasive, and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Alvaro Ducas
- Division of General, Minimally Invasive, and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Jessica Cassiani
- Division of General, Minimally Invasive, and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Luca Morelli
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Gaya Spolverato
- Department of Surgical, Oncological and Gastroenterological Sciences, University of Padova, Padova, Italy
| | - Francesco Maria Bianco
- Division of General, Minimally Invasive, and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
4
|
Subramaniam S, Piozzi GN, Kim SH, Khan JS. Robotic approach to colonic resection: For some or for all patients? Colorectal Dis 2024; 26:1447-1455. [PMID: 38812078 DOI: 10.1111/codi.17046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Accepted: 05/08/2024] [Indexed: 05/31/2024]
Abstract
The robotic approach is rapidly gaining momentum in colorectal surgery. Its benefits in pelvic surgery have been extensively discussed and are well established amongst those who perform minimally invasive surgery. However, the same cannot be said for the robotic approach for colonic resection, where its role is still debated. Here we aim to provide an extensive debate between selective and absolute use of the robotic approach for colonic resection by combining the thoughts of experts in the field of robotic and minimally invasive colorectal surgery, dissecting all key aspects for a critical view on this exciting new paradigm in colorectal surgery.
Collapse
Affiliation(s)
- Sentilnathan Subramaniam
- Colorectal Surgery Unit, Department of General Surgery, Hospital Selayang, Selangor, Malaysia
- Department of Colorectal Surgery, Portsmouth Hospitals University NHS Trust, Portsmouth, UK
| | | | - Seon-Hahn Kim
- Colorectal Unit, Department of Surgery, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Jim S Khan
- Department of Colorectal Surgery, Portsmouth Hospitals University NHS Trust, Portsmouth, UK
- University of Portsmouth, Portsmouth, UK
| |
Collapse
|
5
|
Erozkan K, Gorgun E. Robotic colorectal surgery and future directions. Am J Surg 2024; 230:91-98. [PMID: 37953126 DOI: 10.1016/j.amjsurg.2023.10.046] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 10/22/2023] [Indexed: 11/14/2023]
Abstract
As the adoption of robotic-assisted procedures expands across various surgical specialties, colorectal surgery stands out as a prominent beneficiary. This rise in usage can be traced back to the increased accessibility of robotic platforms and a growing institutional shift towards cutting-edge surgical methods. When compared with traditional laparoscopic methods, robotic techniques offer distinct advantages. Their true potential shines in surgeries involving complex anatomical regions, where the robot's enhanced dexterity and range of motion prove invaluable. The three-dimensional, magnified view provided by robotic systems further boosts surgical precision and clarity. These advantages render robotic assistance especially suitable for colorectal surgeries, notably in intricate areas such as the rectum and endoluminal spaces. As the medical world emphasizes minimally invasive surgical methods, there's a pressing need to evolve and optimize robotic techniques in colorectal surgery. This article traces the evolution of robotic interventions in colorectal surgeries, highlighting both its historical milestones and anticipated future trends. We'll also explore emerging robotic tools and systems set to reshape the colorectal surgical arena.
Collapse
Affiliation(s)
- Kamil Erozkan
- Department of Colorectal Surgery, Digestive Disease and Surgery Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Emre Gorgun
- Department of Colorectal Surgery, Digestive Disease and Surgery Institute, Cleveland Clinic, Cleveland, OH, USA.
| |
Collapse
|
6
|
Kim HJ, Choi GS, Park JS, Park SY, Song SH, Lee SM, Jeong MH. Comparison of the efficacy and safety of single-port versus multi-port robotic total mesorectal excision for rectal cancer: A propensity score-matched analysis. Surgery 2024; 175:297-303. [PMID: 38036394 DOI: 10.1016/j.surg.2023.09.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 07/28/2023] [Accepted: 09/26/2023] [Indexed: 12/02/2023]
Abstract
BACKGROUND It is unknown whether the da Vinci single-port system performs similarly to the previous multi-port system during complicated procedures, such as rectal cancer surgery. Therefore, we compared the short-term clinical outcomes of single-port and multi-port robotic total mesorectal excision for the treatment of rectal cancer. METHODS This retrospective study reviewed 128 patients who underwent robotic total mesorectal excision between July 2020 and June 2022, of whom 84 (42 each: single-port versus multi-port) were included in the propensity score-matched cohort. Perioperative and pathologic outcomes were compared between groups. RESULTS Median tumor height was similar between groups (single-port versus multi-port, 5.9 ± 2.1 vs 5.6 ± 1.8 cm, P = .719). Preoperative chemoradiotherapy was performed equally. The total operative time was less (160.0 ± 42.2 minutes vs 199.6 ± 78.6 minutes, P = .005), the total length of incision was shorter (4.0 ±0.3 vs 5.4 ± 0.7 cm, P = .003), postoperative hospital stay was shorter (6.2 ±1.7 vs 7.2 ±2.8 days, P = .050), and C-reactive protein levels on postoperative day 3 trended to be lower (7.3 ± 4.7 vs 8.9 ± 5.6 mg/L, P = .096) in the single-port group, compared with the multi-port group. Postoperative complications did not differ between groups (single-port versus multi-port, 11.9% vs 16.6%, P = .864). Anastomotic leakage occurred in 1 and 2 patients in the single-port and multi-port groups, respectively. The circumferential resection margins were positive in 1 patient in the multi-port group. CONCLUSION The perioperative outcomes of single-port robotic total mesorectal excision were comparable to those of multi-port robotic TME. The single-port robot can be considered a surgical option for treating rectal cancer.
Collapse
Affiliation(s)
- Hye Jin Kim
- Colorectal Cancer Center, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu, Korea
| | - Gyu-Seog Choi
- Colorectal Cancer Center, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu, Korea.
| | - Jun Seok Park
- Colorectal Cancer Center, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu, Korea
| | - Soo Yeun Park
- Colorectal Cancer Center, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu, Korea
| | - Seung Ho Song
- Colorectal Cancer Center, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu, Korea
| | - Sung Min Lee
- Colorectal Cancer Center, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu, Korea
| | - Min Hye Jeong
- Colorectal Cancer Center, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu, Korea
| |
Collapse
|
7
|
Marks JH, Yang J, Spitz EM, Salem J, Agarwal S, de Paula TR, Schoonyoung HP, Keller DS. A prospective phase II clinical trial/IDEAL Stage 2a series of single-port robotic colorectal surgery for abdominal and transanal cases. Colorectal Dis 2023; 25:2335-2345. [PMID: 37907449 DOI: 10.1111/codi.16788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 08/30/2023] [Accepted: 09/17/2023] [Indexed: 11/02/2023]
Abstract
AIM Slow laparoscopy adoption accelerated the uptake of robotic surgery. However, the current robotic platforms have limitations in transanal applications and multiple port sites. The da Vinci single-port (SP) robot is currently used on trial for colorectal surgery, and broad assessment of outcomes is needed. We aimed to report findings of a phase II clinical trial of SP robotic colorectal surgery. METHODS A sequentially reported prospective case series was performed on patients using SP robotics at a tertiary referral centre from 1 October 2018 to 31 August 2021. Cases were stratified into abdominal and transanal cohorts. Demographics, intra-operative variables and 30-day postoperative outcomes were evaluated. Univariate analysis was performed, with statistical process control for the docking process. Main outcomes were conversion rates, morbidity, mortality and point of standardization of docking. RESULTS In all, 133 patients were included: 93 (69.92%) abdominal and 40 (30.08%) transanal. The main diagnosis was rectal cancer (n = 59) and the procedure performed a robotic transanal abdominal transanal radical proctosigmoidectomy (n = 30). There were no conversions to open surgery. Two abdominal (2.15%) and three transanal cases (7.50%) were converted to laparoscopy. All colorectal adenocarcinomas had negative margins, proper lymph node harvest and complete mesorectal excision, as appropriate. Docking became a standardized process at cases 34 (abdominal) and 23 (anorectal). After surgery, bowel function returned on mean day 2 (abdominal) and 1 (transanal). The morbidity rate was 15.05% (abdominal) and 27.50% (transanal). There were two major morbidities in each cohort. Overall, there were three (2.65%) readmissions, one reoperation and no mortality. CONCLUSIONS Single-port robotics is feasible for all types of colorectal procedures, with good clinical and oncological outcomes. With this development in colorectal surgery, further studies can develop best practices with this novel technology.
Collapse
Affiliation(s)
- John H Marks
- Lankenau Institute for Medical Research and Division of Colon and Rectal Surgery, Department of Surgery, Lankenau Medical Center, Wynnewood, Pennsylvania, USA
| | - Jane Yang
- Division of Colon and Rectal Surgery, Department of Surgery, Lankenau Medical Center, Wynnewood, Pennsylvania, USA
| | - Elizabeth M Spitz
- Lankenau Institute for Medical Research, Lankenau Medical Center, Wynnewood, Pennsylvania, USA
| | - Jean Salem
- Department of Surgery, Saline Health System, Benton, Arkansas, USA
| | - Samir Agarwal
- Department of Surgery, Physician First Group, Sarasota Memorial Health Care System, Sarasota, Florida, USA
| | - Thais Reif de Paula
- Lankenau Institute for Medical Research, Lankenau Medical Center, Wynnewood, Pennsylvania, USA
| | - Henry P Schoonyoung
- Lankenau Institute for Medical Research and Division of Colon and Rectal Surgery, Department of Surgery, Lankenau Medical Center, Wynnewood, Pennsylvania, USA
| | - Deborah S Keller
- Lankenau Institute for Medical Research and Division of Colon and Rectal Surgery, Department of Surgery, Lankenau Medical Center, Wynnewood, Pennsylvania, USA
| |
Collapse
|
8
|
Kim HS, Oh BY, Chung SS, Lee RA, Noh GT. Short-term outcomes of single-incision robotic colectomy versus conventional multiport laparoscopic colectomy for colon cancer. J Robot Surg 2023; 17:2351-2359. [PMID: 37402962 DOI: 10.1007/s11701-023-01666-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 07/02/2023] [Indexed: 07/06/2023]
Abstract
Since the da Vinci SP (dVSP) surgical system was introduced, single-incision robotic surgery (SIRS) for colorectal diseases has gained increasing acceptance. Comparison of the short-term outcomes between SIRS using dVSP and those of conventional multiport laparoscopic surgery (CMLS) was performed to verify its efficacy and safety in colon cancer. The medical records of 237 patients who underwent curative resection for colon cancer by a single surgeon were retrospectively reviewed. Patients were divided into two groups according to surgical modality: SIRS (RS group) and CMLS (LS group). Intra- and postoperative outcomes were analyzed. Of the 237 patients, 140 were included in the analysis. Patients in the RS group (n = 43) were predominantly female, younger, and had better general performance than those in the LS group (n = 97). The total operation time was longer in the RS group than in the LS group (232.8 ± 46.0 vs. 204.1 ± 41.7 min, P < 0.001). The RS group showed faster first flatus passing (2.5 ± 0.9 vs. 3.1 ± 1.2 days, P = 0.003) and less opioid analgesic requirement (analgesic withdrawal within 3 postoperative days: 37.2% vs. 18.6%, P = 0.018) than the LS group. The RS group showed a higher immediate postoperative albumin level (3.9 ± 0.3 vs. 3.6 ± 0.4 g/dL, P < 0.001) and lower C-reactive protein level (6.6 ± 5.2 vs. 9.3 ± 5.5 mg/dL, P = 0.007) than the LS group during the postoperative period. On multivariate analysis after adjusting for deviated patient characteristics, no significant difference was observed in short-term outcomes, except for operation time. SIRS with dVSP showed short-term outcomes comparable with those of CMLS for colon cancer.
Collapse
Affiliation(s)
- Ho Seung Kim
- Department of Surgery, Ewha Womans University College of Medicine, Seoul, South Korea
| | - Bo-Young Oh
- Department of Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, South Korea
| | - Soon Sup Chung
- Department of Surgery, Ewha Womans University College of Medicine, Seoul, South Korea
| | - Ryung-Ah Lee
- Department of Surgery, Ewha Womans University College of Medicine, Seoul, South Korea
| | - Gyoung Tae Noh
- Department of Surgery, Ewha Womans University College of Medicine, Seoul, South Korea.
| |
Collapse
|
9
|
Marchegiani F, Siragusa L, Zadoroznyj A, Laterza V, Mangana O, Schena CA, Ammendola M, Memeo R, Bianchi PP, Spinoglio G, Gavriilidis P, de'Angelis N. New Robotic Platforms in General Surgery: What's the Current Clinical Scenario? MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1264. [PMID: 37512075 PMCID: PMC10386395 DOI: 10.3390/medicina59071264] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 07/01/2023] [Accepted: 07/04/2023] [Indexed: 07/30/2023]
Abstract
Background and Objectives: Robotic surgery has been widely adopted in general surgery worldwide but access to this technology is still limited to a few hospitals. With the recent introduction of new robotic platforms, several studies reported the feasibility of different surgical procedures. The aim of this systematic review is to highlight the current clinical practice with the new robotic platforms in general surgery. Materials and Methods: A grey literature search was performed on the Internet to identify the available robotic systems. A PRISMA compliant systematic review was conducted for all English articles up to 10 February 2023 searching the following databases: MEDLINE, EMBASE, and Cochrane Library. Clinical outcomes, training process, operating surgeon background, cost-analysis, and specific registries were evaluated. Results: A total of 103 studies were included for qualitative synthesis after the full-text screening. Of the fifteen robotic platforms identified, only seven were adopted in a clinical environment. Out of 4053 patients, 2819 were operated on with a new robotic device. Hepatopancreatobiliary surgery specialty performed the majority of procedures, and the most performed procedure was cholecystectomy. Globally, 109 emergency surgeries were reported. Concerning the training process, only 45 papers reported the background of the operating surgeon, and only 28 papers described the training process on the surgical platform. Only one cost-analysis compared a new robot to the existing reference. Two manufacturers promoted a specific registry to collect clinical outcomes. Conclusions: This systematic review highlights the feasibility of most surgical procedures in general surgery using the new robotic platforms. Adoption of these new devices in general surgery is constantly growing with the extension of regulatory approvals. Standardization of the training process and the assessment of skills' transferability is still lacking. Further studies are required to better understand the real clinical and economical benefit.
Collapse
Affiliation(s)
- Francesco Marchegiani
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France
| | - Leandro Siragusa
- Department of Surgical Sciences, University of Rome "Tor Vergata", Viale Oxford 81, 00133 Rome, Italy
| | - Alizée Zadoroznyj
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France
| | - Vito Laterza
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France
| | - Orsalia Mangana
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France
| | - Carlo Alberto Schena
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France
| | - Michele Ammendola
- Science of Health Department, Digestive Surgery Unit, University "Magna Graecia" Medical School, 88100 Catanzaro, Italy
| | - Riccardo Memeo
- Unit of Hepato-Pancreato-Biliary Surgery, General Regional Hospital "F. Miulli", 70021 Acquaviva delle Fonti, Italy
| | - Paolo Pietro Bianchi
- Division of General and Robotic Surgery, Department of Health Sciences, San Paolo Hospital, University of Milan, 20142 Milan, Italy
| | - Giuseppe Spinoglio
- Research Institute Against Digestive Cancer (IRCAD), 67000 Strasbourg, France
| | - Paschalis Gavriilidis
- Department of Surgery, Saint Helena General Hospital, Jamestown, Saint Helena STHL 1ZZ, South Atlantic Ocean, UK
| | - Nicola de'Angelis
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France
| |
Collapse
|
10
|
Kim HS, Oh BY, Cheong C, Park MH, Chung SS, Lee RA, Kim KH, Noh GT. Single-incision robotic colorectal surgery with the da Vinci SP® surgical system: initial results of 50 cases. Tech Coloproctol 2023; 27:589-599. [PMID: 36971849 DOI: 10.1007/s10151-023-02791-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 03/14/2023] [Indexed: 06/06/2023]
Abstract
PURPOSE The da Vinci SP® (dVSP) surgical system (Intuitive Surgical, Sunnyvale, CA, USA), a robotic platform designed for single-incision surgery, overcame the need for multiple ports in traditional robotic surgery and issues including triangulation and retraction in single-incision laparoscopic surgery. However, previous studies only included case reports or series with small sample sizes. The aim of this study was to assess the safety and performance of the dVSP surgical system and its instruments and accessories for colorectal procedures. METHODS The medical records of patients who had surgery with the dVSP from March 2019 to September 2021 at Ewha Womans University Seoul Hospital were investigated. The pathologic and follow-up data of patients who had malignant tumors were analyzed separately to evaluate oncological safety. RESULTS Fifty patients (26 male and 24 female) with a median age of 59 years (interquartile range 52.5-63.0 years) were enrolled. The procedures included low anterior resection with total mesorectal excision (n = 16), sigmoid colectomy with complete mesocolic excision and central vessel ligation (CME + CVL) (n = 14), right colectomy with CME + CVL (n = 9), left colectomy with CME + CVL (n = 4), right colectomy (n = 6), and sigmoid colectomy (n = 1). Operative time significantly decreased after 25 cases (early phase vs. late phase; operative time 295.0 min vs. 250.0 min, p = 0.015; docking time 16.0 min vs. 12.0 min, p = 0.001; console time 212.0 min vs. 190.0 min, p = 0.019). Planned procedures were successfully completed in all patients. Postoperative outcomes were acceptable with only six cases of mild adverse events through a 3-month follow-up. No local recurrence and only one case of systemic recurrence occurred within 1 year postoperatively. CONCLUSIONS This study demonstrated the surgical and oncological safety and feasibility of dVSP, which may be a novel surgical platform for colorectal surgery.
Collapse
Affiliation(s)
- H S Kim
- Department of Surgery, Ewha Womans University College of Medicine, 260, Gonghang-Daero, Gangseo-Gu, Seoul, 07804, South Korea
| | - B-Y Oh
- Department of Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, South Korea
| | - C Cheong
- Department of Surgery, Korea University Guro Hospital, Korea University College of Medicine, Seoul, South Korea
| | - M H Park
- Ewha Womans University Seoul Hospital, Seoul, South Korea
| | - S S Chung
- Department of Surgery, Ewha Womans University College of Medicine, 260, Gonghang-Daero, Gangseo-Gu, Seoul, 07804, South Korea
| | - R-A Lee
- Department of Surgery, Ewha Womans University College of Medicine, 260, Gonghang-Daero, Gangseo-Gu, Seoul, 07804, South Korea
| | - K H Kim
- Department of Surgery, Ewha Womans University College of Medicine, 260, Gonghang-Daero, Gangseo-Gu, Seoul, 07804, South Korea
| | - G T Noh
- Department of Surgery, Ewha Womans University College of Medicine, 260, Gonghang-Daero, Gangseo-Gu, Seoul, 07804, South Korea.
| |
Collapse
|
11
|
Lim JH, Yun SH, Lee WY, Kim HC, Cho YB, Huh JW, Park YA, Shin JK. Single-port laparoscopic versus single-port robotic right hemicolectomy: Postoperative short-term outcomes. Int J Med Robot 2023; 19:e2509. [PMID: 36809565 DOI: 10.1002/rcs.2509] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2022] [Revised: 01/31/2023] [Accepted: 02/13/2023] [Indexed: 02/23/2023]
Abstract
BACKGROUND This study aimed to compare the short-term postoperative outcomes of single-port robotic (SPR) using da Vinci SP® system and single port laparoscopic (SPL) right hemicolectomy and determine whether the novel SPR system is safe and feasible. METHODS From January 2019 to December 2020, a total of 141 patients (41 patients for SPR and 100 patients for SPL) who electively underwent right hemicolectomy for colon cancer performed by a single surgeon were included in the study. RESULTS The time to the first bowel movement was 3 (range, 1-4) days after surgery in the SPR group and 3 (2-9, range) days in the SPL group (p = 0.017). However, there were no differences in pathologic outcomes or postoperative complications. CONCLUSIONS SPR is a safe and feasible surgical technique and has an advantage in the time to first postoperative bowel movement over SPL with no other complications.
Collapse
Affiliation(s)
- Ji Ha Lim
- Department of Surgery, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon, Korea
| | - Seong Hyeon Yun
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Woo Yong Lee
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hee Cheol Kim
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yong Beom Cho
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jung Wook Huh
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Yoon Ah Park
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jung Kyong Shin
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
12
|
Minimally invasive surgery for colorectal cancer, a look back to look forward: a personal history. JOURNAL OF MINIMALLY INVASIVE SURGERY 2022; 25:41-48. [PMID: 35821687 PMCID: PMC9218402 DOI: 10.7602/jmis.2022.25.2.41] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 06/10/2022] [Accepted: 06/10/2022] [Indexed: 11/11/2022]
Abstract
While laparoscopic colonoscopy was reported by several surgeons in the early 1990s, laparoscopic colorectal surgery has been attempted sporadically since 1992 in Korea. Then, in 2000, the Korean Laparoscopic Colorectal Surgery Study Group was established. Didactic lectures, videos, and live surgery by the early pioneers of this group inspired and helped many surgeons initiate the laparoscopic approach to the treatment of colorectal disease. As a result, the penetration rate of minimally invasive colorectal cancer surgery nationwide is increasing to 80% in 2018. As a witness on this journey, I would like to share my personal minimally invasive colorectal cancer surgery history and perspectives on future surgery in this field.
Collapse
|
13
|
Cui H, Cui JX, Zhang KC, Liang WQ, Li SY, Huang J, Chen L, Wei B. Can a single-port robot be safely used for robotic total gastrectomy for advanced gastric cancer? First experience using the da Vinci SP platform. Gastroenterol Rep (Oxf) 2022; 10:goac023. [PMID: 35686174 PMCID: PMC9172626 DOI: 10.1093/gastro/goac023] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 05/03/2022] [Accepted: 05/04/2022] [Indexed: 11/13/2022] Open
Abstract
Background Many studies have shown the operative feasibility and safety of robotic gastrectomy. Surgeons are pursuing single-port (SP) surgery to leverage the advantages of minimally invasive gastrectomy. The purpose of this study was to describe technical considerations and short-term outcomes from the first reported SP robotic total gastrectomy (RTG) using the da Vinci SP platform. Methods A 75-year-old patient with a body-mass index of 19.8 kg/m2 and clinical stage III cancer (cT3N+M0) underwent SP RTG on 22 January 2022 at the Department of General Surgery, the Chinese PLA General Hospital. All procedures were performed successfully using the da Vinci SP robotic platform. Results The SP RTG was successfully performed with D2 lymphadenectomy including No. 10 lymph-nodes dissection and extracorporeal Roux-en-Y anastomosis. Except for subcutaneous emphysema, no severe adverse events occurred during the operation. According to a visual analogue scale (VAS), the subjective feeling of post-operative pain was given a VAS score of 3 of 10 on Post-Operative Day 1 (POD 1), 1 of 10 on POD 3, and 1 of 10 on POD 7. We removed the gastric tube on POD 2 and advised sipping water, a liquid diet, and a soft diet on PODs 2, 4, and 6, respectively. The patient was discharged without any complications on POD 8. Conclusion RTG is technically feasible and safe using the da Vinci SP robotic platform. To our knowledge, this is the first study using the da Vinci SP platform in RTG for advanced gastric cancer in elderly patients. To verify its superior operative outcomes, further clinical trials are needed.
Collapse
Affiliation(s)
- Hao Cui
- Department of General Surgery, The First Medical Center, Chinese PLA General Hospital , Beijing, P. R. China
- School of Medicine, Nankai University , Tianjin, P. R. China
| | - Jian-Xin Cui
- Department of General Surgery, The First Medical Center, Chinese PLA General Hospital , Beijing, P. R. China
| | - Ke-Cheng Zhang
- Department of General Surgery, The First Medical Center, Chinese PLA General Hospital , Beijing, P. R. China
| | - Wen-Quan Liang
- Department of General Surgery, The First Medical Center, Chinese PLA General Hospital , Beijing, P. R. China
| | - Shu-Yan Li
- Foreign Languages College, Shandong University of Traditional Chinese Medicine , Jinan, Shandong, P. R. China
| | - Jun Huang
- Department of General Surgery, The First Medical Center, Chinese PLA General Hospital , Beijing, P. R. China
- School of Medicine, Nankai University , Tianjin, P. R. China
| | - Lin Chen
- Department of General Surgery, The First Medical Center, Chinese PLA General Hospital , Beijing, P. R. China
- School of Medicine, Nankai University , Tianjin, P. R. China
| | - Bo Wei
- Department of General Surgery, The First Medical Center, Chinese PLA General Hospital , Beijing, P. R. China
- School of Medicine, Nankai University , Tianjin, P. R. China
| |
Collapse
|
14
|
Piozzi GN, Kim JS, Choo JM, Shin SH, Kim JS, Lee TH, Baek SJ, Kwak JM, Kim J, Kim SH. Da Vinci SP robotic approach to colorectal surgery: two specific indications and short-term results. Tech Coloproctol 2022; 26:461-470. [PMID: 35182278 DOI: 10.1007/s10151-022-02597-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 02/04/2022] [Indexed: 01/17/2023]
Abstract
BACKGROUND Da Vinci® Single Port (dvSP) was recently developed. Its application in colorectal surgery is under investigation. The aim of this study was to explore the safety and feasibility of dvSP for intersphincteric (dvSP-ISR), right colectomy (dvSP-RC), and transverse colectomy (dvSP-TC). Surgical indication and short-term results were analyzed. METHODS All consecutive patients from a prospective database of patients who underwent dvSP-ISR, dvSP-RC, and dvSP-TC at Korea University Anam Hospital from November 2020 to December 2021, were analyzed. Perioperative, pathological, and oncological short-term outcomes were analyzed. RESULTS A total of 7 dvSP-ISR, 5 dvSP-RC, and 1 dvSP-TC were performed. Median age was 56.0 (55.0-61.0) years for the dvSP-ISR and 54.0 (44.7-63.5) years for the dvSP-RC/TC. Median body mass index was 22.8 (17.1-24.8) kg/m2 for the dvSP-ISR and 23.6 (20.8-26.9) kg/m2 for the dvSP-RC/TC. All dvSP-ISR patients received neoadjuvant long-course chemoradiotherapy, including one patient with squamocellular carcinoma who was treated with 5-fluorouracil (5-FU)/mitomycin. All other patients, excluding one dvSP-RC patient with Crohn's disease, had an adenocarcinoma. Median operation time was 280 (240-370) minutes for the dvSP-ISR and 220 (201-270) minutes for the dvSP-RC/TC. Estimated blood loss was insignificant. No intraoperative complications or conversions to multiport/open surgery was reported. Median post-operative stay was 7.0 (6.0-10.0) days for the dvSP-ISR and 5.0 (4.0-6.7) days for the dvSP-RC/TC. Quality of mesorectum was complete for six patients, and nearly complete for one. Median number of retrieved lymph nodes were 21 (17-25) for the dvSP-ISR and 28 (24-49) for the dvSP-RC/TC. Proximal and distal resection margins were tumor free. Four patients experienced post-operative complications not related to the platform which were: ileus, voiding dysfunction, infected pelvic hematoma, and wound infection. Median follow-up was 9 (6-11) months and 11 (7-17) months for the dvSP-ISR and dvSP-RC/TC, respectively. Two patients had systemic recurrence; all others were tumor free. CONCLUSIONS The dvSP platform is safe and feasible for intersphincteric resection with right lower quadrant access, and right/transverse colectomy with suprapubic access. Further studies are needed to evaluate benefit differences compared to multiport robotic platform.
Collapse
Affiliation(s)
- G N Piozzi
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - J-S Kim
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - J M Choo
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - S H Shin
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - J S Kim
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - T-H Lee
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - S-J Baek
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - J-M Kwak
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - J Kim
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - S H Kim
- Division of Colon and Rectal Surgery, Department of Surgery, Korea University Anam Hospital, Korea University College of Medicine, 73 Goryodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
| |
Collapse
|