1
|
Guérit F, Middlebrooks JC, Gransier R, Richardson ML, Wouters J, Carlyon RP. Exploring the Use of Interleaved Stimuli to Measure Cochlear-Implant Excitation Patterns. J Assoc Res Otolaryngol 2024; 25:201-213. [PMID: 38459245 PMCID: PMC11018570 DOI: 10.1007/s10162-024-00937-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 02/15/2024] [Indexed: 03/10/2024] Open
Abstract
PURPOSE Attempts to use current-focussing strategies with cochlear implants (CI) to reduce neural spread-of-excitation have met with only mixed success in human studies, in contrast to promising results in animal studies. Although this discrepancy could stem from between-species anatomical and aetiological differences, the masking experiments used in human studies may be insufficiently sensitive to differences in excitation-pattern width. METHODS We used an interleaved-masking method to measure psychophysical excitation patterns in seven participants with four masker stimulation configurations: monopolar (MP), partial tripolar (pTP), a wider partial tripolar (pTP + 2), and, importantly, a condition (RP + 2) designed to produce a broader excitation pattern than MP. The probe was always in partial-tripolar configuration. RESULTS We found a significant effect of stimulation configuration on both the amount of on-site masking (mask and probe on same electrode; an indirect indicator of sharpness) and the difference between off-site and on-site masking. Differences were driven solely by RP + 2 producing a broader excitation pattern than the other configurations, whereas monopolar and the two current-focussing configurations did not statistically differ from each other. CONCLUSION A method that is sensitive enough to reveal a modest broadening in RP + 2 showed no evidence for sharpening with focussed stimulation. We also showed that although voltage recordings from the implant accurately predicted a broadening of the psychophysical excitation patterns with RP + 2, they wrongly predicted a strong sharpening with pTP + 2. We additionally argue, based on our recent research, that the interleaved-masking method can usefully be applied to non-human species and objective measures of CI excitation patterns.
Collapse
Affiliation(s)
- François Guérit
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England.
| | - John C Middlebrooks
- Department of Otolaryngology, University of California at Irvine, Irvine, CA, USA
- Department of Neurobiology and Behavior, University of California at Irvine, Irvine, CA, USA
- Department of Biomedical Engineering, University of California at Irvine, Irvine, CA, USA
| | - Robin Gransier
- Department of Neurosciences, ExpORL KU Leuven, Leuven, Belgium
- Leuven Brain Institute KU Leuven, Leuven, Belgium
| | - Matthew L Richardson
- Department of Otolaryngology, University of California at Irvine, Irvine, CA, USA
| | - Jan Wouters
- Department of Neurosciences, ExpORL KU Leuven, Leuven, Belgium
- Leuven Brain Institute KU Leuven, Leuven, Belgium
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| |
Collapse
|
2
|
Huang Z, Chen S, Zhang G, Almadhor A, Li R, Li M, Abbas M, Nguyen Le B, Zhang J, Huang Y. Nanocatalysts as fast and powerful medical intervention: Bridging cochlear implant therapies and advanced modelling using Hidden Markov Models (HMMs) for effective treatment of infections. ENVIRONMENTAL RESEARCH 2023:116285. [PMID: 37301496 DOI: 10.1016/j.envres.2023.116285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 05/23/2023] [Accepted: 05/29/2023] [Indexed: 06/12/2023]
Abstract
As human population growth and waste from technologically advanced industries threaten to destabilise our delicate ecological equilibrium, the global spotlight intensifies on environmental contamination and climate-related changes. These challenges extend beyond our external environment and have significant effects on our internal ecosystems. The inner ear, which is responsible for balance and auditory perception, is a prime example. When these sensory mechanisms are impaired, disorders such as deafness can develop. Traditional treatment methods, including systemic antibiotics, are frequently ineffective due to inadequate inner ear penetration. Conventional techniques for administering substances to the inner ear fail to obtain adequate concentrations as well. In this context, cochlear implants laden with nanocatalysts emerge as a promising strategy for the targeted treatment of inner ear infections. Coated with biocompatible nanoparticles containing specific nanocatalysts, these implants can degrade or neutralise contaminants linked to inner ear infections. This method enables the controlled release of nanocatalysts directly at the infection site, thereby maximising therapeutic efficacy and minimising adverse effects. In vivo and in vitro studies have demonstrated that these implants are effective at eliminating infections, reducing inflammation, and fostering tissue regeneration in the ear. This study investigates the application of hidden Markov models (HMMs) to nanocatalyst-loaded cochlear implants. The HMM is trained on surgical phases in order to accurately identify the various phases associated with implant utilisation. This facilitates the precision placement of surgical instruments within the ear, with a location accuracy between 91% and 95% and a standard deviation between 1% and 5% for both sites. In conclusion, nanocatalysts serve as potent medicinal instruments, bridging cochlear implant therapies and advanced modelling utilising hidden Markov models for the effective treatment of inner ear infections. Cochlear implants loaded with nanocatalysts offer a promising method to combat inner ear infections and enhance patient outcomes by addressing the limitations of conventional treatments.
Collapse
|
3
|
Tahmasebi S, Segovia-Martinez M, Nogueira W. Optimization of Sound Coding Strategies to Make Singing Music More Accessible for Cochlear Implant Users. Trends Hear 2023; 27:23312165221148022. [PMID: 36628453 PMCID: PMC9837293 DOI: 10.1177/23312165221148022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
Cochlear implants (CIs) are implantable medical devices that can partially restore hearing to people suffering from profound sensorineural hearing loss. While these devices provide good speech understanding in quiet, many CI users face difficulties when listening to music. Reasons include poor spatial specificity of electric stimulation, limited transmission of spectral and temporal fine structure of acoustic signals, and restrictions in the dynamic range that can be conveyed via electric stimulation of the auditory nerve. The coding strategies currently used in CIs are typically designed for speech rather than music. This work investigates the optimization of CI coding strategies to make singing music more accessible to CI users. The aim is to reduce the spectral complexity of music by selecting fewer bands for stimulation, attenuating the background instruments by strengthening a noise reduction algorithm, and optimizing the electric dynamic range through a back-end compressor. The optimizations were evaluated through both objective and perceptual measures of speech understanding and melody identification of singing voice with and without background instruments, as well as music appreciation questionnaires. Consistent with the objective measures, results gathered from the perceptual evaluations indicated that reducing the number of selected bands and optimizing the electric dynamic range significantly improved speech understanding in music. Moreover, results obtained from questionnaires show that the new music back-end compressor significantly improved music enjoyment. These results have potential as a new CI program for improved singing music perception.
Collapse
Affiliation(s)
- Sina Tahmasebi
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence Hearing4all, Hannover, Germany
- Sina Tahmasebi, Karl-Wiechert-Allee 3, 30625 Hannover, Germany.
Waldo Nogueira, Karl-Wiechert-Allee 3, 30625 Hannover, Germany.
| | | | - Waldo Nogueira
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence Hearing4all, Hannover, Germany
- Sina Tahmasebi, Karl-Wiechert-Allee 3, 30625 Hannover, Germany.
Waldo Nogueira, Karl-Wiechert-Allee 3, 30625 Hannover, Germany.
| |
Collapse
|
4
|
Guérit F, Middlebrooks JC, Richardson ML, Arneja A, Harland AJ, Gransier R, Wouters J, Carlyon RP. Tonotopic Selectivity in Cats and Humans: Electrophysiology and Psychophysics. J Assoc Res Otolaryngol 2022; 23:513-534. [PMID: 35697952 PMCID: PMC9437197 DOI: 10.1007/s10162-022-00851-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 05/02/2022] [Indexed: 01/06/2023] Open
Abstract
We describe a scalp-recorded measure of tonotopic selectivity, the "cortical onset response" (COR) and compare the results between humans and cats. The COR results, in turn, were compared with psychophysical masked-detection thresholds obtained using similar stimuli and obtained from both species. The COR consisted of averaged responses elicited by 50-ms tone-burst probes presented at 1-s intervals against a continuous noise masker. The noise masker had a bandwidth of 1 or 1/8th octave, geometrically centred on 4000 Hz for humans and on 8000 Hz for cats. The probe frequency was either - 0.5, - 0.25, 0, 0.25 or 0.5 octaves re the masker centre frequency. The COR was larger for probe frequencies more distant from the centre frequency of the masker, and this effect was greater for the 1/8th-octave than for the 1-octave masker. This pattern broadly reflected the masked excitation patterns obtained psychophysically with similar stimuli in both species. However, the positive signal-to-noise ratio used to obtain reliable COR measures meant that some aspects of the data differed from those obtained psychophysically, in a way that could be partly explained by the upward spread of the probe's excitation pattern. Our psychophysical measurements also showed that the auditory filter width obtained at 8000 Hz using notched-noise maskers was slightly wider in cat than previous measures from humans. We argue that although conclusions from COR measures differ in some ways from conclusions based on psychophysics, the COR measures provide an objective, noninvasive, valid measure of tonotopic selectivity that does not require training and that may be applied to acoustic and cochlear-implant experiments in humans and laboratory animals.
Collapse
Affiliation(s)
- Francois Guérit
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - John C. Middlebrooks
- grid.266093.80000 0001 0668 7243Department of Otolaryngology, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Neurobiology and Behavior, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Cognitive Sciences, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Biomedical Engineering, University of California at Irvine, Irvine, CA USA
| | - Matthew L. Richardson
- grid.266093.80000 0001 0668 7243Department of Otolaryngology, University of California at Irvine, Irvine, CA USA
| | - Akshat Arneja
- grid.266093.80000 0001 0668 7243Department of Cognitive Sciences, University of California at Irvine, Irvine, CA USA
| | - Andrew J. Harland
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - Robin Gransier
- Dept. of Neurosciences, ExpORL, Leuven, Louvain, KU Belgium
| | - Jan Wouters
- Dept. of Neurosciences, ExpORL, Leuven, Louvain, KU Belgium
| | - Robert P. Carlyon
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| |
Collapse
|
5
|
Recent Advances in Cochlear Implant Electrode Array Design Parameters. MICROMACHINES 2022; 13:mi13071081. [PMID: 35888898 PMCID: PMC9323156 DOI: 10.3390/mi13071081] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 06/29/2022] [Accepted: 06/30/2022] [Indexed: 02/04/2023]
Abstract
Cochlear implants are neural implant devices that aim to restore hearing in patients with severe sensorineural hearing impairment. Here, the main goal is to successfully place the electrode array in the cochlea to stimulate the auditory nerves through bypassing damaged hair cells. Several electrode and electrode array parameters affect the success of this technique, but, undoubtedly, the most important one is related to electrodes, which are used for nerve stimulation. In this paper, we provide a comprehensive resource on the electrodes currently being used in cochlear implant devices. Electrode materials, shape, and the effect of spacing between electrodes on the stimulation, stiffness, and flexibility of electrode-carrying arrays are discussed. The use of sensors and the electrical, mechanical, and electrochemical properties of electrode arrays are examined. A large library of preferred electrodes is reviewed, and recent progress in electrode design parameters is analyzed. Finally, the limitations and challenges of the current technology are discussed along with a proposal of future directions in the field.
Collapse
|
6
|
Landsberger DM, Stupak N, Spitzer ER, Entwisle L, Mahoney L, Waltzman SB, McMenomey S, Friedmann DR, Svirsky MA, Shapiro W, Roland JT. Stimulating the Cochlear Apex Without Longer Electrodes: Preliminary Results With a New Approach. Otol Neurotol 2022; 43:e578-e581. [PMID: 35283466 PMCID: PMC9149041 DOI: 10.1097/mao.0000000000003529] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE To investigate a new surgical and signal processing technique that provides apical stimulation of the cochlea using a cochlear implant without extending the length of the electrode array. PATIENTS Three adult patients who underwent cochlear implantation using this new technique. INTERVENTIONS The patients received a cochlear implant. The surgery differed from the standard approach in that a ground electrode was placed in the cochlear helicotrema via an apical cochleostomy rather than in its typical location underneath the temporalis muscle. Clinical fitting was modified such that low frequencies were represented using the apically placed electrode as a ground. MAIN OUTCOME MEASURES Pitch scaling and speech recognition. RESULTS All surgeries were successful with no complications. Pitch scaling demonstrated that use of the apically placed electrode as a ground lowered the perceived pitch of electric stimulation relative to monopolar stimulation. Speech understanding was improved compared with preoperative scores. CONCLUSIONS The new surgical approach and clinical fitting are feasible. A lower pitch is perceived when using the apically placed electrode as a ground relative to stimulation using an extracochlear ground (i.e., monopolar mode), suggesting that stimulation can be provided more apically without the use of a longer electrode array. Further work is required to determine potential improvements in outcomes and optimal signal processing for the new approach.
Collapse
Affiliation(s)
- David M Landsberger
- Department of Otolaryngology, New York University Grossman School of Medicine, New York, New York
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Garadat SN, Colesa DJ, Swiderski DL, Raphael Y, Pfingst BE. Estimating health of the implanted cochlea using psychophysical strength-duration functions and electrode configuration. Hear Res 2022; 414:108404. [PMID: 34883366 PMCID: PMC8761176 DOI: 10.1016/j.heares.2021.108404] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 11/17/2021] [Accepted: 11/25/2021] [Indexed: 02/03/2023]
Abstract
It is generally believed that the efficacy of cochlear implants is partly dependent on the condition of the stimulated neural population. Cochlear pathology is likely to affect the manner in which neurons respond to electrical stimulation, potentially resulting in differences in perception of electrical stimuli across cochlear implant recipients and across the electrode array in individual cochlear implant users. Several psychophysical and electrophysiological measures have been shown to predict cochlear health in animals and were used to assess conditions near individual stimulation sites in humans. In this study, we examined the relationship between psychophysical strength-duration functions and spiral ganglion neuron density in two groups of guinea pigs with cochlear implants who had minimally-overlapping cochlear health profiles. One group was implanted in a hearing ear (N = 10) and the other group was deafened by cochlear perfusion of neomycin, inoculated with an adeno-associated viral vector with an Ntf3-gene insert (AAV.Ntf3) and implanted (N = 14). Psychophysically measured strength-duration functions for both monopolar and tripolar electrode configurations were then compared for the two treatment groups. Results were also compared to their histological outcomes. Overall, there were considerable differences between the two treatment groups in terms of their psychophysical performance as well as the relation between their functional performance and histological data. Animals in the neomycin-deafened, neurotrophin-treated, and implanted group (NNI) exhibited steeper strength-duration function slopes; slopes were positively correlated with SGN density (steeper slopes in animals that had higher SGN densities). In comparison, the implanted hearing (IH) group had shallower slopes and there was no relation between slopes and spiral ganglion density. Across all animals, slopes were negatively correlated with ensemble spontaneous activity levels (shallower slopes with higher ensemble spontaneous activity levels). We hypothesize that differences in strength-duration function slopes between the two treatment groups were related to the condition of the inner hair cells, which generate spontaneous activity that could affect the across-fiber synchrony and/or the size of the population of neural elements responding to electrical stimulation. In addition, it is likely that spiral ganglion neuron peripheral processes were present in the IH group, which could affect membrane properties of the stimulated neurons. Results suggest that the two treatment groups exhibited distinct patterns of variation in conditions near the stimulating electrodes that altered detection thresholds. Overall, the results of this study suggest a complex relationship between psychophysical detection thresholds for cochlear implant stimulation and nerve survival in the implanted cochlea. This relationship seems to depend on the characteristics of the electrical stimulus, the electrode configuration, and other biological features of the implanted cochlea such as the condition of the inner hair cells and the peripheral processes.
Collapse
Affiliation(s)
- Soha N. Garadat
- Department of Hearing and Speech Sciences, The University of Jordan, Amman, 11942, Jordan,Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| | - Deborah J. Colesa
- Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| | - Donald L. Swiderski
- Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| | - Yehoash Raphael
- Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| | - Bryan E. Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology—Head and Neck Surgery, University of Michigan, Ann Arbor, MI 48109-5616, USA
| |
Collapse
|
8
|
Jahn KN, DeVries L, Arenberg JG. Recovery from forward masking in cochlear implant listeners: Effects of age and the electrode-neuron interface. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:1633. [PMID: 33765782 PMCID: PMC8267874 DOI: 10.1121/10.0003623] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 02/12/2021] [Accepted: 02/12/2021] [Indexed: 06/12/2023]
Abstract
Older adults exhibit deficits in auditory temporal processing relative to younger listeners. These age-related temporal processing difficulties may be further exacerbated in older adults with cochlear implant (CIs) when CI electrodes poorly interface with their target auditory neurons. The aim of this study was to evaluate the potential interaction between chronological age and the estimated quality of the electrode-neuron interface (ENI) on psychophysical forward masking recovery, a measure that reflects single-channel temporal processing abilities. Fourteen CI listeners (age 15 to 88 years) with Advanced Bionics devices participated. Forward masking recovery was assessed on two channels in each ear (i.e., the channels with the lowest and highest signal detection thresholds). Results indicated that the rate of forward masking recovery declined with advancing age, and that the effect of age was more pronounced on channels estimated to interface poorly with the auditory nerve. These findings indicate that the quality of the ENI can influence the time course of forward masking recovery for older CI listeners. Channel-to-channel variability in the ENI likely interacts with central temporal processing deficits secondary to auditory aging, warranting further study of programming and rehabilitative approaches tailored to older listeners.
Collapse
Affiliation(s)
- Kelly N Jahn
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington 98105, USA
| | - Lindsay DeVries
- Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland 20742, USA
| | - Julie G Arenberg
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington 98105, USA
| |
Collapse
|
9
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition with cochlear implants as a function of the number of channels: Effects of electrode placement. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:3646. [PMID: 32486813 PMCID: PMC7255811 DOI: 10.1121/10.0001316] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 05/08/2020] [Accepted: 05/08/2020] [Indexed: 05/28/2023]
Abstract
This study investigated the effects of cochlear implant (CI) electrode array type and scalar location on the number of channels available to CI recipients for maximum speech understanding and sound quality. Eighteen post-lingually deafened adult CI recipients participated, including 11 recipients with straight electrode arrays entirely in scala tympani and 7 recipients with translocated precurved electrode arrays. Computerized tomography was used to determine electrode placement and scalar location. In each condition, the number of channels varied from 4 to 22 with equal spatial distribution across the array. Speech recognition (monosyllables, sentences in quiet and in noise), subjective speech sound quality, and closed-set auditory tasks (vowels, consonants, and spectral modulation detection) were measured acutely. Recipients with well-placed straight electrode arrays and translocated precurved electrode arrays performed similarly, demonstrating asymptotic speech recognition scores with 8-10 channels, consistent with the classic literature. This finding contrasts with recent work [Berg, Noble, Dawant, Dwyer, Labadie, and Gifford. (2019). J. Acoust. Soc. Am. 145, 1556-1564] that found precurved electrode arrays well-placed in scala tympani demonstrate continuous performance gains beyond 8-10 channels. Given these results, straight and translocated precurved electrode arrays are theorized to have less channel independence secondary to their placement farther away from neural targets.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
10
|
Feng L, Oxenham AJ. Auditory enhancement and the role of spectral resolution in normal-hearing listeners and cochlear-implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:552. [PMID: 30180692 PMCID: PMC6072550 DOI: 10.1121/1.5048414] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 06/25/2018] [Accepted: 07/11/2018] [Indexed: 05/17/2023]
Abstract
Detection of a target tone in a simultaneous multi-tone masker can be improved by preceding the stimulus with the masker alone. The mechanisms underlying this auditory enhancement effect may enable the efficient detection of new acoustic events and may help to produce perceptual constancy under varying acoustic conditions. Previous work in cochlear-implant (CI) users has suggested reduced or absent enhancement, due perhaps to poor spatial resolution in the cochlea. This study used a supra-threshold enhancement paradigm that in normal-hearing listeners results in large enhancement effects, exceeding 20 dB. Results from vocoder simulations using normal-hearing listeners showed that near-normal enhancement was observed if the simulated spread of excitation was limited to spectral slopes no shallower than 24 dB/oct. No significant enhancement was observed on average in CI users with their clinical monopolar stimulation strategy. The variability in enhancement between CI users, and between electrodes in a single CI user, could not be explained by the spread of excitation, as estimated from auditory nerve evoked potentials. Enhancement remained small, but did reach statistical significance, under the narrower partial-tripolar stimulation strategy. The results suggest that enhancement may be at least partially restored by improvements in the spatial resolution of current CIs.
Collapse
Affiliation(s)
- Lei Feng
- Department of Psychology, University of Minnesota, N218 Elliott Hall, 75 East River Parkway, Minneapolis, Minnesota 55455, USA
| | - Andrew J Oxenham
- Department of Psychology, University of Minnesota, N218 Elliott Hall, 75 East River Parkway, Minneapolis, Minnesota 55455, USA
| |
Collapse
|
11
|
Spitzer ER, Hughes ML. Effect of Stimulus Polarity on Physiological Spread of Excitation in Cochlear Implants. J Am Acad Audiol 2018; 28:786-798. [PMID: 28972468 DOI: 10.3766/jaaa.16144] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Contemporary cochlear implants (CIs) use cathodic-leading, symmetrical, biphasic current pulses, despite a growing body of evidence that suggests anodic-leading pulses may be more effective at stimulating the auditory system. However, since much of this research on humans has used pseudomonophasic pulses or biphasic pulses with unusually long interphase gaps, the effects of stimulus polarity are unclear for clinically relevant (i.e., symmetric biphasic) stimuli. PURPOSE The purpose of this study was to examine the effects of stimulus polarity on basic characteristics of physiological spread-of-excitation (SOE) measures obtained with the electrically evoked compound action potential (ECAP) in CI recipients using clinically relevant stimuli. RESEARCH DESIGN Using a within-subjects (repeated measures) design, we examined the differences in mean amplitude, peak electrode location, area under the curve, and spatial separation between SOE curves obtained with anodic- and cathodic-leading symmetrical, biphasic pulses. STUDY SAMPLE Fifteen CI recipients (ages 13-77) participated in this study. All were users of Cochlear Ltd. devices. DATA COLLECTION AND ANALYSIS SOE functions were obtained using the standard forward-masking artifact reduction method. Probe electrodes were 5-18, and they were stimulated at an 8 (of 10) loudness rating ("loud"). Outcome measures (mean amplitude, peak electrode location, curve area, and spatial separation) for each polarity were compared within subjects. RESULTS Anodic-leading current pulses produced ECAPs with larger average amplitudes, greater curve area, and less spatial separation between SOE patterns compared with that for cathodic-leading pulses. There was no effect of polarity on peak electrode location. CONCLUSIONS These results indicate that for equal current levels, the anodic-leading polarity produces broader excitation patterns compared with cathodic-leading pulses, which reduces the spatial separation between functions. This result is likely due to preferential stimulation of the central axon. Further research is needed to determine whether SOE patterns obtained with anodic-leading pulses better predict pitch discrimination.
Collapse
Affiliation(s)
- Emily R Spitzer
- Boys Town National Research Hospital, Omaha, NE.,University of North Carolina-Chapel Hill, Chapel Hill, NC
| | | |
Collapse
|
12
|
Quass GL, Kurt S, Hildebrandt KJ, Kral A. Electrical stimulation of the midbrain excites the auditory cortex asymmetrically. Brain Stimul 2018; 11:1161-1174. [PMID: 29853311 DOI: 10.1016/j.brs.2018.05.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 05/09/2018] [Accepted: 05/10/2018] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Auditory midbrain implant users cannot achieve open speech perception and have limited frequency resolution. It remains unclear whether the spread of excitation contributes to this issue and how much it can be compensated by current-focusing, which is an effective approach in cochlear implants. OBJECTIVE The present study examined the spread of excitation in the cortex elicited by electric midbrain stimulation. We further tested whether current-focusing via bipolar and tripolar stimulation is effective with electric midbrain stimulation and whether these modes hold any advantage over monopolar stimulation also in conditions when the stimulation electrodes are in direct contact with the target tissue. METHODS Using penetrating multielectrode arrays, we recorded cortical population responses to single pulse electric midbrain stimulation in 10 ketamine/xylazine anesthetized mice. We compared monopolar, bipolar, and tripolar stimulation configurations with regard to the spread of excitation and the characteristic frequency difference between the stimulation/recording electrodes. RESULTS The cortical responses were distributed asymmetrically around the characteristic frequency of the stimulated midbrain region with a strong activation in regions tuned up to one octave higher. We found no significant differences between monopolar, bipolar, and tripolar stimulation in threshold, evoked firing rate, or dynamic range. CONCLUSION The cortical responses to electric midbrain stimulation are biased towards higher tonotopic frequencies. Current-focusing is not effective in direct contact electrical stimulation. Electrode maps should account for the asymmetrical spread of excitation when fitting auditory midbrain implants by shifting the frequency-bands downward and stimulating as dorsally as possible.
Collapse
Affiliation(s)
- Gunnar Lennart Quass
- Institute of AudioNeuroTechnology (VIANNA), Dept. of Experimental Otology, ENT Clinics, Hannover Medical School, 30625 Hannover, Germany; Cluster of Excellence "Hearing4all", Germany.
| | - Simone Kurt
- Institute of AudioNeuroTechnology (VIANNA), Dept. of Experimental Otology, ENT Clinics, Hannover Medical School, 30625 Hannover, Germany; Cluster of Excellence "Hearing4all", Germany
| | - K Jannis Hildebrandt
- Cluster of Excellence "Hearing4all", Germany; Research Center Neurosensory Science, University of Oldenburg, 26111 Oldenburg, Germany
| | - Andrej Kral
- Institute of AudioNeuroTechnology (VIANNA), Dept. of Experimental Otology, ENT Clinics, Hannover Medical School, 30625 Hannover, Germany; Cluster of Excellence "Hearing4all", Germany
| |
Collapse
|
13
|
Carlyon RP, Deeks JM, Undurraga J, Macherey O, van Wieringen A. Spatial Selectivity in Cochlear Implants: Effects of Asymmetric Waveforms and Development of a Single-Point Measure. J Assoc Res Otolaryngol 2017; 18:711-727. [PMID: 28755309 PMCID: PMC5612920 DOI: 10.1007/s10162-017-0625-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Accepted: 05/05/2017] [Indexed: 01/07/2023] Open
Abstract
Three experiments studied the extent to which cochlear implant users' spatial selectivity can be manipulated using asymmetric waveforms and tested an efficient method for comparing spatial selectivity produced by different stimuli. Experiment 1 measured forward-masked psychophysical tuning curves (PTCs) for a partial tripolar (pTP) probe. Maskers were presented on bipolar pairs separated by one unused electrode; waveforms were either symmetric biphasic ("SYM") or pseudomonophasic with the short high-amplitude phase being either anodic ("PSA") or cathodic ("PSC") on the more apical electrode. For the SYM masker, several subjects showed PTCs consistent with a bimodal excitation pattern, with discrete excitation peaks on each electrode of the bipolar masker pair. Most subjects showed significant differences between the PSA and PSC maskers consistent with greater masking by the electrode where the high-amplitude phase was anodic, but the pattern differed markedly across subjects. Experiment 2 measured masked excitation patterns for a pTP probe and either a monopolar symmetric biphasic masker ("MP_SYM") or pTP pseudomonophasic maskers where the short high-amplitude phase was either anodic ("TP_PSA") or cathodic ("TP_PSC") on the masker's central electrode. Four of the five subjects showed significant differences between the masker types, but again the pattern varied markedly across subjects. Because the levels of the maskers were chosen to produce the same masking of a probe on the same channel as the masker, it was correctly predicted that maskers that produce broader masking patterns would sound louder. Experiment 3 exploited this finding by using a single-point measure of spread of excitation to reveal significantly better spatial selectivity for TP_PSA compared to TP_PSC maskers.
Collapse
Affiliation(s)
- Robert P Carlyon
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK
| | - John M Deeks
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK.
| | - Jaime Undurraga
- ExpORL, Department of Neurosciences, KULeuven, Herestraat 49 bus 721, 3000, Leuven, Belgium
| | - Olivier Macherey
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB1 3DA, UK
- LMA-CNRS, UPR 7051, Aix-Marseille University, Centrale Marseille, 4, Impasse Nikola Tesla, CS40006, 13453, Marseille Cedex 13, France
| | - Astrid van Wieringen
- ExpORL, Department of Neurosciences, KULeuven, Herestraat 49 bus 721, 3000, Leuven, Belgium
| |
Collapse
|
14
|
Pure-Tone Masking Patterns for Monopolar and Phantom Electrical Stimulation in Cochlear Implants. Ear Hear 2017; 39:124-130. [PMID: 28700446 DOI: 10.1097/aud.0000000000000471] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Monopolar stimulation of the most apical electrode produces the lowest pitch sensation in cochlear implants clinically. A phantom electrode that uses out-of-phase electrical stimulation between the most apical and the neighboring basal electrode can produce a lower pitch sensation than that associated with the most apical electrode. However, because of the absence of contacts beyond the apical tip of the array, the ability to assess the spread of electrical excitation associated with phantom stimulation is limited in the typical cochlear implant subject with no residual hearing. In the present study, the spread of electrical excitation associated with monopolar and phantom stimulation of the most apical electrode was assessed using electrical masking of acoustic thresholds in cochlear implant subjects with residual, low-frequency, acoustic hearing. DESIGN Eight subjects with an Advanced Bionics cochlear implant and residual hearing in the implanted ear participated in this study (nine ears in total). Unmasked and masked thresholds for acoustic pure tones were measured at 125, 250, 500, 750, 1000, and 2000 Hz in the presence of monopolar and phantom electrode stimulation presented at the apical-most end of the array. The current compensation for phantom electrode stimulation was fixed at 50%. The two electrical maskers were loudness balanced. Differences between the unmasked and masked acoustic thresholds can be attributed to (1) the electrical stimulus-induced interference in the transduction/conduction of the acoustic signal through cochlear periphery and the auditory nerve and/or (2) masking at the level of the central auditory system. RESULTS The results show a significant elevation in pure-tone thresholds in the presence of the monopolar and phantom electrical maskers. The unmasked thresholds were subtracted from the masked thresholds to derive masking patterns as a function of the acoustic probe frequency. The masking patterns show that phantom stimulation was able to produce more masking than that associated with the monopolar stimulation of the most apical electrode. CONCLUSION These results suggest that for some cochlear implant subjects, phantom electrode stimulation can shift the neural stimulation pattern more apically in the cochlea, which is consistent with reports that phantom electrode stimulation produces lower pitch sensations than those associated with monopolar stimulation of the most apical electrode alone.
Collapse
|
15
|
Hughes ML, Goehring JL, Baudhuin JL, Schmid KK. Effects of stimulus level and rate on psychophysical thresholds for interleaved pulse trains in cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:2297. [PMID: 27794318 PMCID: PMC6910005 DOI: 10.1121/1.4963903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 09/09/2016] [Accepted: 09/14/2016] [Indexed: 06/06/2023]
Abstract
This study examined channel interactions using interleaved pulse trains to assess masking and potential facilitative effects in cochlear-implant recipients using clinically relevant stimuli. Psychophysical thresholds were measured for two adjacent mid-array electrodes; one served as the masker and the other as the probe. Two rates representative of those found in present-day strategies were tested: 1700 and 3400 pulses per second per channel. Four masker levels ranging from sub-threshold to loud-but-comfortable were tested. It was hypothesized that low-level maskers would produce facilitative effects, shifting to masking effects at high levels, and that faster rates would yield smaller masking effects due to greater stochastic neural firing patterns. Twenty-nine ears with Cochlear or Advanced Bionics devices were tested. High-level maskers produced more masking than low-level maskers, as expected. Facilitation was not observed for sub-threshold or threshold-level maskers in most cases. High masker levels yielded reduced probe thresholds for two Advanced Bionics subjects. This was partly eliminated with a longer temporal offset between each masker-probe pulse pair, as was used with Cochlear subjects. These findings support the use of temporal gaps between stimulation of subsequent electrodes to reduce channel interactions.
Collapse
Affiliation(s)
- Michelle L Hughes
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Jenny L Goehring
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Jacquelyn L Baudhuin
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Kendra K Schmid
- Department of Biostatistics, 984375 University of Nebraska Medical Center, Omaha, Nebraska 68198-4375, USA
| |
Collapse
|
16
|
George SS, Shivdasani MN, Fallon JB. Effect of current focusing on the sensitivity of inferior colliculus neurons to amplitude-modulated stimulation. J Neurophysiol 2016; 116:1104-16. [PMID: 27306672 DOI: 10.1152/jn.00126.2016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Accepted: 06/15/2016] [Indexed: 11/22/2022] Open
Abstract
In multichannel cochlear implants (CIs), current is delivered to specific electrodes along the cochlea in the form of amplitude-modulated pulse trains, to convey temporal and spectral cues. Our previous studies have shown that focused multipolar (FMP) and tripolar (TP) stimulation produce more restricted neural activation and reduced channel interactions in the inferior colliculus (IC) compared with traditional monopolar (MP) stimulation, suggesting that focusing of stimulation could produce better transmission of spectral information. The present study explored the capability of IC neurons to detect modulated CI stimulation with FMP and TP stimulation compared with MP stimulation. The study examined multiunit responses of IC neurons in acutely deafened guinea pigs by systematically varying the stimulation configuration, modulation depth, and stimulation level. Stimuli were sinusoidal amplitude-modulated pulse trains (carrier rate of 120 pulses/s). Modulation sensitivity was quantified by measuring modulation detection thresholds (MDTs), defined as the lowest modulation depth required to differentiate the response of a modulated stimulus from an unmodulated one. Whereas MP stimulation showed significantly lower MDTs than FMP and TP stimulation (P values <0.05) at stimulation ≤2 dB above threshold, all stimulation configurations were found to have similar modulation sensitivities at 4 dB above threshold. There was no difference found in modulation sensitivity between FMP and TP stimulation. The present study demonstrates that current focusing techniques such as FMP and TP can adequately convey amplitude modulation and are comparable to MP stimulation, especially at higher stimulation levels, although there may be some trade-off between spectral and temporal fidelity with current focusing stimulation.
Collapse
Affiliation(s)
- Shefin S George
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| | - Mohit N Shivdasani
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| | - James B Fallon
- The Bionics Institute, East Melbourne, Australia; and Department of Medical Bionics, University of Melbourne, Melbourne, Australia
| |
Collapse
|
17
|
Bierer JA, Litvak L. Reducing Channel Interaction Through Cochlear Implant Programming May Improve Speech Perception: Current Focusing and Channel Deactivation. Trends Hear 2016; 20:20/0/2331216516653389. [PMID: 27317668 PMCID: PMC4948253 DOI: 10.1177/2331216516653389] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Abstract
Speech perception among cochlear implant (CI) listeners is highly variable. High degrees of channel interaction are associated with poorer speech understanding. Two methods for reducing channel interaction, focusing electrical fields, and deactivating subsets of channels were assessed by the change in vowel and consonant identification scores with different program settings. The main hypotheses were that (a) focused stimulation will improve phoneme recognition and (b) speech perception will improve when channels with high thresholds are deactivated. To select high-threshold channels for deactivation, subjects’ threshold profiles were processed to enhance the peaks and troughs, and then an exclusion or inclusion criterion based on the mean and standard deviation was used. Low-threshold channels were selected manually and matched in number and apex-to-base distribution. Nine ears in eight adult CI listeners with Advanced Bionics HiRes90k devices were tested with six experimental programs. Two, all-channel programs, (a) 14-channel partial tripolar (pTP) and (b) 14-channel monopolar (MP), and four variable-channel programs, derived from these two base programs, (c) pTP with high- and (d) low-threshold channels deactivated, and (e) MP with high- and (f) low-threshold channels deactivated, were created. Across subjects, performance was similar with pTP and MP programs. However, poorer performing subjects (scoring < 62% correct on vowel identification) tended to perform better with the all-channel pTP than with the MP program (1 > 2). These same subjects showed slightly more benefit with the reduced channel MP programs (5 and 6). Subjective ratings were consistent with performance. These finding suggest that reducing channel interaction may benefit poorer performing CI listeners.
Collapse
|
18
|
Wu CC, Luo X. Excitation Patterns of Standard and Steered Partial Tripolar Stimuli in Cochlear Implants. J Assoc Res Otolaryngol 2015; 17:145-58. [PMID: 26691160 DOI: 10.1007/s10162-015-0549-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2015] [Accepted: 11/25/2015] [Indexed: 11/25/2022] Open
Abstract
Current steering in partial tripolar (pTP) mode has been shown to improve pitch perception and spectral resolution with cochlear implants (CIs). In this mode, a fraction (σ) of the main electrode current is returned within the cochlea and steered between the basal and apical flanking electrodes (with a proportion of α and 1 - α, respectively). Pitch generally decreases when α increases from 0 to 1, although the salience of pitch change varies across CI users. This study aimed to identify the mechanism of pitch changes with pTP-mode current steering and the factors contributing to the intersubject variability in pitch-ranking sensitivity. The electrical fields were measured for steered pTP stimuli on the same main electrode with α = 0, 0.5, and 1 in five implanted ears using electrical field imaging (EFI). The related excitation patterns were also measured physiologically using evoked compound action potential (ECAP) and psychophysically using psychophysical forward masking (PFM). Consistent with the pitch-ranking results in this study, the EFI, ECAP, and PFM centroids shifted apically with increasing α. An apical shift was also observed for the PFM peak but not for the EFI or ECAP peak. The pattern width was similar with different α values within a given measure (e.g., EFI, ECAP, or PFM), but the ECAP patterns were broader than the EFI and PFM patterns, possibly because ECAP was measured with smaller σ values than EFI and PFM. The amount of pattern shift with α depended on σ (i.e., the total amount of current used for steering) but was not correlated with the pitch-ranking sensitivity across subjects. The results revealed that the pitch changes elicited by pTP-mode current steering were not only driven by the shifts of excitation centroid.
Collapse
Affiliation(s)
- Ching-Chih Wu
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, IN, 47907, USA
- School of Electrical and Computer Engineering, Purdue University, 715 Clinic Drive, West Lafayette, IN, 47907, USA
| | - Xin Luo
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, IN, 47907, USA.
- Department of Speech and Hearing Science, Arizona State University, Coor Hall, 975 S. Myrtle Av., P. O. Box 870102, Tempe, AZ, 85287, USA.
| |
Collapse
|
19
|
Galvin JJ, Oba SI, Başkent D, Chatterjee M, Fu QJ. Envelope Interactions in Multi-Channel Amplitude Modulation Frequency Discrimination by Cochlear Implant Users. PLoS One 2015; 10:e0139546. [PMID: 26431043 PMCID: PMC4592255 DOI: 10.1371/journal.pone.0139546] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Accepted: 09/15/2015] [Indexed: 11/29/2022] Open
Abstract
Rationale Previous cochlear implant (CI) studies have shown that single-channel amplitude modulation frequency discrimination (AMFD) can be improved when coherent modulation is delivered to additional channels. It is unclear whether the multi-channel advantage is due to increased loudness, multiple envelope representations, or to component channels with better temporal processing. Measuring envelope interference may shed light on how modulated channels can be combined. Methods In this study, multi-channel AMFD was measured in CI subjects using a 3-alternative forced-choice, non-adaptive procedure (“which interval is different?”). For the reference stimulus, the reference AM (100 Hz) was delivered to all 3 channels. For the probe stimulus, the target AM (101, 102, 104, 108, 116, 132, 164, 228, or 256 Hz) was delivered to 1 of 3 channels, and the reference AM (100 Hz) delivered to the other 2 channels. The spacing between electrodes was varied to be wide or narrow to test different degrees of channel interaction. Results Results showed that CI subjects were highly sensitive to interactions between the reference and target envelopes. However, performance was non-monotonic as a function of target AM frequency. For the wide spacing, there was significantly less envelope interaction when the target AM was delivered to the basal channel. For the narrow spacing, there was no effect of target AM channel. The present data were also compared to a related previous study in which the target AM was delivered to a single channel or to all 3 channels. AMFD was much better with multiple than with single channels whether the target AM was delivered to 1 of 3 or to all 3 channels. For very small differences between the reference and target AM frequencies (2–4 Hz), there was often greater sensitivity when the target AM was delivered to 1 of 3 channels versus all 3 channels, especially for narrowly spaced electrodes. Conclusions Besides the increased loudness, the present results also suggest that multiple envelope representations may contribute to the multi-channel advantage observed in previous AMFD studies. The different patterns of results for the wide and narrow spacing suggest a peripheral contribution to multi-channel temporal processing. Because the effect of target AM frequency was non-monotonic in this study, adaptive procedures may not be suitable to measure AMFD thresholds with interfering envelopes. Envelope interactions among multiple channels may be quite complex, depending on the envelope information presented to each channel and the relative independence of the stimulated channels.
Collapse
Affiliation(s)
- John J. Galvin
- Department of Head and Neck Surgery, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, United States of America
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Research School of Behavioral and Cognitive Neurosciences, Graduate School of Medical Sciences, University of Groningen, Groningen, The Netherlands
- * E-mail: (JG)
| | - Sandra I. Oba
- Department of Head and Neck Surgery, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, United States of America
| | - Deniz Başkent
- Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Research School of Behavioral and Cognitive Neurosciences, Graduate School of Medical Sciences, University of Groningen, Groningen, The Netherlands
| | - Monita Chatterjee
- Auditory Prostheses & Perception Lab, Boys Town National Research Hospital, Omaha, Nebraska, United States of America
| | - Qian-Jie Fu
- Department of Head and Neck Surgery, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, United States of America
| |
Collapse
|
20
|
Egger K, Majdak P, Laback B. Channel Interaction and Current Level Affect Across-Electrode Integration of Interaural Time Differences in Bilateral Cochlear-Implant Listeners. J Assoc Res Otolaryngol 2015; 17:55-67. [PMID: 26377826 DOI: 10.1007/s10162-015-0542-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Accepted: 08/30/2015] [Indexed: 11/26/2022] Open
Abstract
Sensitivity to interaural time differences (ITDs) is important for sound localization. Normal-hearing listeners benefit from across-frequency processing, as seen with improved ITD thresholds when consistent ITD cues are presented over a range of frequency channels compared with when ITD information is only presented in a single frequency channel. This study aimed to clarify whether cochlear-implant (CI) listeners can make use of similar processing when being stimulated with multiple interaural electrode pairs transmitting consistent ITD information. ITD thresholds for unmodulated, 100-pulse-per-second pulse trains were measured in seven bilateral CI listeners using research interfaces. Consistent ITDs were presented at either one or two electrode pairs at different current levels, allowing for comparisons at either constant level per component electrode or equal overall loudness. Different tonotopic distances between the pairs were tested in order to clarify the potential influence of channel interaction. Comparison of ITD thresholds between double pairs and the respective single pairs revealed systematic effects of tonotopic separation and current level. At constant levels, performance with double-pair stimulation improved compared with single-pair stimulation but only for large tonotopic separation. Comparisons at equal overall loudness revealed no benefit from presenting ITD information at two electrode pairs for any tonotopic spacing. Irrespective of electrode-pair configuration, ITD sensitivity improved with increasing current level. Hence, the improved ITD sensitivity for double pairs found for a large tonotopic separation and constant current levels seems to be due to increased loudness. The overall data suggest that CI listeners can benefit from combining consistent ITD information across multiple electrodes, provided sufficient stimulus levels and that stimulating electrode pairs are widely spaced.
Collapse
Affiliation(s)
- Katharina Egger
- Acoustics Research Institute, Austrian Academy of Sciences, Wohllebengasse 12-14, 1040, Vienna, Austria.
| | - Piotr Majdak
- Acoustics Research Institute, Austrian Academy of Sciences, Wohllebengasse 12-14, 1040, Vienna, Austria.
| | - Bernhard Laback
- Acoustics Research Institute, Austrian Academy of Sciences, Wohllebengasse 12-14, 1040, Vienna, Austria.
| |
Collapse
|
21
|
Perception and coding of interaural time differences with bilateral cochlear implants. Hear Res 2015; 322:138-50. [DOI: 10.1016/j.heares.2014.10.004] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 10/01/2014] [Accepted: 10/07/2014] [Indexed: 11/21/2022]
|
22
|
Shannon RV. Auditory implant research at the House Ear Institute 1989-2013. Hear Res 2015; 322:57-66. [PMID: 25449009 PMCID: PMC4380593 DOI: 10.1016/j.heares.2014.11.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 11/04/2014] [Accepted: 11/07/2014] [Indexed: 11/29/2022]
Abstract
The House Ear Institute (HEI) had a long and distinguished history of auditory implant innovation and development. Early clinical innovations include being one of the first cochlear implant (CI) centers, being the first center to implant a child with a cochlear implant in the US, developing the auditory brainstem implant, and developing multiple surgical approaches and tools for Otology. This paper reviews the second stage of auditory implant research at House - in-depth basic research on perceptual capabilities and signal processing for both cochlear implants and auditory brainstem implants. Psychophysical studies characterized the loudness and temporal perceptual properties of electrical stimulation as a function of electrical parameters. Speech studies with the noise-band vocoder showed that only four bands of tonotopically arrayed information were sufficient for speech recognition, and that most implant users were receiving the equivalent of 8-10 bands of information. The noise-band vocoder allowed us to evaluate the effects of the manipulation of the number of bands, the alignment of the bands with the original tonotopic map, and distortions in the tonotopic mapping, including holes in the neural representation. Stimulation pulse rate was shown to have only a small effect on speech recognition. Electric fields were manipulated in position and sharpness, showing the potential benefit of improved tonotopic selectivity. Auditory training shows great promise for improving speech recognition for all patients. And the Auditory Brainstem Implant was developed and improved and its application expanded to new populations. Overall, the last 25 years of research at HEI helped increase the basic scientific understanding of electrical stimulation of hearing and contributed to the improved outcomes for patients with the CI and ABI devices. This article is part of a Special Issue entitled .
Collapse
Affiliation(s)
- Robert V Shannon
- Department of Otolaryngology, University of Southern California, Keck School of Medicine of USC, 806 W. Adams Blvd, Los Angeles, CA 90007-2505, USA.
| |
Collapse
|
23
|
Mesnildrey Q, Macherey O. Simulating the dual-peak excitation pattern produced by bipolar stimulation of a cochlear implant: effects on speech intelligibility. Hear Res 2014; 319:32-47. [PMID: 25449010 DOI: 10.1016/j.heares.2014.11.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Revised: 10/28/2014] [Accepted: 11/05/2014] [Indexed: 10/24/2022]
Abstract
Several electrophysiological and psychophysical studies have shown that the spatial excitation pattern produced by bipolar stimulation of a cochlear implant (CI) can have a dual-peak shape. The perceptual effects of this dual-peak shape were investigated using noise-vocoded CI simulations in which synthesis filters were designed to simulate the spread of neural activity produced by various electrode configurations, as predicted by a simple cochlear model. Experiments 1 and 2 tested speech recognition in the presence of a concurrent speech masker for various sets of single-peak and dual-peak synthesis filters and different numbers of channels. Similarly as results obtained in real CIs, both monopolar (MP, single-peak) and bipolar (BP + 1, dual-peak) simulations showed a plateau of performance above 8 channels. The benefit of increasing the number of channels was also lower for BP + 1 than for MP. This shows that channel interactions in BP + 1 become especially deleterious for speech intelligibility when a simulated electrode acts both as an active and as a return electrode for different channels because envelope information from two different analysis bands are being conveyed to the same spectral location. Experiment 3 shows that these channel interactions are even stronger in wide BP configuration (BP + 5), likely because the interfering speech envelopes are less correlated than in narrow BP + 1. Although the exact effects of dual- or multi-peak excitation in real CIs remain to be determined, this series of experiments suggest that multipolar stimulation strategies, such as bipolar or tripolar, should be controlled to avoid neural excitation in the vicinity of the return electrodes.
Collapse
Affiliation(s)
- Quentin Mesnildrey
- LMA-CNRS, UPR 7051, Aix-Marseille Univ., Centrale Marseille, 31 Chemin Joseph Aiguier, 13402 Marseille Cedex 20, France.
| | - Olivier Macherey
- LMA-CNRS, UPR 7051, Aix-Marseille Univ., Centrale Marseille, 31 Chemin Joseph Aiguier, 13402 Marseille Cedex 20, France
| |
Collapse
|
24
|
Zhou N, Pfingst BE. Relationship between multipulse integration and speech recognition with cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 136:1257. [PMID: 25190399 PMCID: PMC4165232 DOI: 10.1121/1.4890640] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Comparisons of performance with cochlear implants and postmortem conditions in the cochlea in humans have shown mixed results. The limitations in those studies favor the use of within-subject designs and non-invasive measures to estimate cochlear conditions. One non-invasive correlate of cochlear health is multipulse integration, established in an animal model. The present study used this measure to relate neural health in human cochlear implant users to their speech recognition performance. The multipulse-integration slopes were derived based on psychophysical detection thresholds measured for two pulse rates (80 and 640 pulses per second). A within-subject design was used in eight subjects with bilateral implants where the direction and magnitude of ear differences in the multipulse-integration slopes were compared with those of the speech-recognition results. The speech measures included speech reception threshold for sentences and phoneme recognition in noise. The magnitude of ear difference in the integration slopes was significantly correlated with the magnitude of ear difference in speech reception thresholds, consonant recognition in noise, and transmission of place of articulation of consonants. These results suggest that multipulse integration predicts speech recognition in noise and perception of features that use dynamic spectral cues.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina 27834
| | - Bryan E Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, Ann Arbor, Michigan 48109-5616
| |
Collapse
|
25
|
Fielden CA, Kluk K, McKay CM. Place specificity of monopolar and tripolar stimuli in cochlear implants: the influence of residual masking. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:4109-4123. [PMID: 23742363 DOI: 10.1121/1.4803909] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This experiment investigated whether place specificity of neural activity evoked by cochlear implant stimulation is improved in tripolar compared to monopolar mode using a forward masking protocol addressing some limitations of previous methods of measurement and analysis. The amount of residual masking (masking remaining at long masker-probe delays) was also measured, and its potential influence on the specificity measures was evaluated. The masker stimulus comprised equally loud interleaved mono- or tripolar stimulation on two electrodes equidistant from a central probe electrode in an apical and basal direction, reducing the influence of off-site listening. The effect of masker-probe distance on the threshold shift of the tripolar probe was analyzed to derive a measure of place specificity. On average, tripolar maskers were more place specific than monopolar maskers, although the mean effect was small. There was no significant effect of masker level on specificity or on the differences observed between modes. The mean influence of residual masking on normalized masking functions was similar for the two modes and, therefore, did not influence the comparison of specificity between the modes. However, variability in amount of residual masking was observed between subjects, and therefore should be considered in forward masking studies that compare place specificity across subjects.
Collapse
Affiliation(s)
- Claire A Fielden
- School of Psychological Sciences, Ellen Wilkinson Building, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom.
| | | | | |
Collapse
|
26
|
Saoji AA, Landsberger DM, Padilla M, Litvak LM. Masking patterns for monopolar and phantom electrode stimulation in cochlear implants. Hear Res 2013; 298:109-16. [PMID: 23299125 PMCID: PMC3755121 DOI: 10.1016/j.heares.2012.12.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2012] [Revised: 12/05/2012] [Accepted: 12/12/2012] [Indexed: 11/16/2022]
Abstract
Phantom electrode (PE) stimulation consists of out-of-phase stimulation of two electrodes. When presented at the apex of the electrode array, phantom stimulation is known to produce a lower pitch sensation than monopolar (MP) stimulation on the most apical electrode. The ratio of the current between the primary electrode (PEL) and the compensating electrode (CEL) is represented by the coefficient σ, which ranges from 0 (monopolar) to 1 (full bipolar). The exact mechanism by which PE stimulation produces a lower pitch sensation is unclear. In the present study, unmasked and masked thresholds were obtained using a forward masking paradigm to estimate the spread of current for MP and PE stimulation. Masked thresholds were measured for two phantom electrode configurations (1) PEL = 4, CEL = 5 (lower pitch phantom) and (2) PEL = 4, CEL = 3 (higher pitch phantom). The unmasked thresholds were subtracted from the masked thresholds to obtain masking patterns which were normalized to their peak. The masking patterns reveal (1) differences in the spread of excitation that are consistent with the direction of pitch shift produced by PE stimulation, and (2) narrower spread of electrical excitation for PE stimulation relative to MP stimulation.
Collapse
Affiliation(s)
- Aniket A. Saoji
- Research and Technology group, Advanced Bionics, LLC, 28515 Westinghouse Place, Valencia CA 91355, USA
| | | | - Monica Padilla
- House Research Institute, 2100 West 3rd Street, Los Angeles, CA 90057, USA
| | - Leonid M. Litvak
- Research and Technology group, Advanced Bionics, LLC, 28515 Westinghouse Place, Valencia CA 91355, USA
| |
Collapse
|
27
|
Spread of excitation varies for different electrical pulse shapes and stimulation modes in cochlear implants. Hear Res 2012; 290:21-36. [DOI: 10.1016/j.heares.2012.05.003] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2012] [Revised: 04/23/2012] [Accepted: 05/04/2012] [Indexed: 11/20/2022]
|
28
|
Preliminary results of the relationship between the binaural interaction component of the electrically evoked auditory brainstem response and interaural pitch comparisons in bilateral cochlear implant recipients. Ear Hear 2012; 33:57-68. [PMID: 21730858 DOI: 10.1097/aud.0b013e31822519ef] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE : The purpose of this study was to investigate the relationship between electrophysiologic measures of the binaural interaction component (BIC) of the electrically evoked auditory brainstem response and psychophysical measures of interaural pitch comparisons in Nucleus bilateral cochlear implant users. DESIGN : Data were collected for 10 postlingually deafened adult cochlear implant users. Each subject conducted an interaural pitch-comparison task using a biphasic pulse train with a pulse rate of 1000 pulses per second (pps) at high stimulation levels. Stimuli were presented in a two-interval, two-alternative forced-choice procedure with roving current variations. A subgroup of four subjects repeated the task at low stimulation levels. BICs were measured using loudness balanced, biphasic current pulses presented at a rate of 19.9 pps for each subject by pairing the electrode 12 (out of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The BIC was measured at high stimulation levels in 10 subjects and at low stimulation levels in 7 subjects. Because of differences in stimulation rate used in BIC measures and interaural pitch comparisons, the actual stimulation levels were different in these two measures. The relationship between BIC responses and results of interaural pitch comparisons was evaluated for each of the individual subjects and at the group level. Evaluation was carried out separately for results obtained at high and low stimulation levels. RESULTS : There was no significant correlation between results of BIC measures and interaural pitch comparisons on either the individual or group levels. Lower stimulation level did not improve the relationship between these two measures. CONCLUSIONS : No significant correlations between psychophysical measures of interaural pitch comparisons and electrophysiologic measures of the BIC of the electrically evoked auditory brainstem response were found. The lack of correlation may be attributed to methods used to quantify the data, small number of subjects retested at low stimulation levels, and central processing components involved in the interaural pitch-comparison task.
Collapse
|
29
|
McKay CM. Forward masking as a method of measuring place specificity of neural excitation in cochlear implants: a review of methods and interpretation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 131:2209-24. [PMID: 22423717 DOI: 10.1121/1.3683248] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
This paper reviews the psychophysical forward masking methods that have been used to investigate place specificity in cochlear implantees. These experiments are relevant for investigating whether the individual variability in outcomes for people using the same device can be explained by individual variations in frequency resolution or whether place specificity is affected by different modes of stimulation (such as bipolar, monopolar or tripolar) in the same person. Unfortunately, there has been no consensus about the methods used to derive electrical forward masking functions, or in the way that they are interpreted in relation to place specificity. Here, the different methods are critically examined to provide insight into the optimal methods that should be used to measure and interpret spatial forward masking functions in electric hearing. It is shown that, in order to separate the temporal effects of masking decay from the place-specificity information, different analyses of the functions are needed depending on whether a fixed-probe or fixed-masker method is employed. The effects of unit of measurement on specificity measures and the effects of subject listening strategy on the forward masked functions are also discussed.
Collapse
Affiliation(s)
- Colette M McKay
- School of Psychological Sciences, University of Manchester, Oxford Road, Manchester, M33 3GH, United Kingdom.
| |
Collapse
|
30
|
Zhu Z, Tang Q, Zeng FG, Guan T, Ye D. Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation. Hear Res 2012; 283:45-58. [PMID: 22138630 PMCID: PMC3277661 DOI: 10.1016/j.heares.2011.11.005] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2010] [Revised: 10/28/2011] [Accepted: 11/08/2011] [Indexed: 11/21/2022]
Abstract
Sharp spatial selectivity is critical to auditory performance, particularly in pitch-related tasks. Most contemporary cochlear implants have employed monopolar stimulation that produces broad electric fields, which presumably contribute to poor pitch and pitch-related performance by implant users. Bipolar or tripolar stimulation can generate focused electric fields but requires higher current to reach threshold and, more interestingly, has not produced any apparent improvement in cochlear-implant performance. The present study addressed this dilemma by measuring psychophysical and physiological spatial selectivity with both broad and focused stimulations in the same cohort of subjects. Different current levels were adjusted by systematically measuring loudness growth for each stimulus, each stimulation mode, and in each subject. Both psychophysical and physiological measures showed that, although focused stimulation produced significantly sharper spatial tuning than monopolar stimulation, it could shift the tuning position or even split the tuning tips. The altered tuning with focused stimulation is interpreted as a result of poor electrode-to-neuron interface in the cochlea, and is suggested to be mainly responsible for the lack of consistent improvement in implant performance. A linear model could satisfactorily quantify the psychophysical and physiological data and derive the tuning width. Significant correlation was found between the individual physiological and psychophysical tuning widths, and the correlation was improved by log-linearly transforming the physiological data to predict the psychophysical data. Because the physiological measure took only one-tenth of the time of the psychophysical measure, the present model is of high clinical significance in terms of predicting and improving cochlear-implant performance.
Collapse
Affiliation(s)
- Ziyan Zhu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
| | | | | | | | | |
Collapse
|
31
|
Pfingst BE. Effects of electrode configuration on cochlear implant modulation detection thresholds. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:3908-3915. [PMID: 21682413 PMCID: PMC3135147 DOI: 10.1121/1.3583543] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2010] [Revised: 03/18/2011] [Accepted: 04/02/2011] [Indexed: 05/28/2023]
Abstract
Cochlear implant function, as assessed by psychophysical measures, varies from one stimulation site to another within a patient's cochlea. This suggests that patient performance might be improved by selection of the best-functioning sites for the processor map. In evaluating stimulation sites for such a strategy, electrode configuration is an important variable. Variation across stimulation sites in loudness-related measures (detection thresholds and maximum comfortable loudness levels), is much larger for stimulation with bipolar electrode configurations than with monopolar configurations. The current study found that, in contrast to the loudness-related measures, magnitudes of across-site means and the across-site variances of modulation detection thresholds were not dependent on electrode configuration, suggesting that the mechanisms underlying variation in these various psychophysical measures are not all the same. The data presented here suggest that bipolar and monopolar electrode configurations are equally effective in identifying good and poor stimulation sites for modulation detection but that the across-site patterns of modulation detection thresholds are not the same for the two configurations. Therefore, it is recommended to test all stimulation sites using the patient's clinically assigned electrode configuration when performing psychophysical evaluation of a patient's modulation detection acuity to select sites for the processor map.
Collapse
Affiliation(s)
- Bryan E Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology, University of Michigan, Ann Arbor, Michigan 48109-5616, USA.
| |
Collapse
|
32
|
Bierer JA. Probing the electrode-neuron interface with focused cochlear implant stimulation. Trends Amplif 2010; 14:84-95. [PMID: 20724356 DOI: 10.1177/1084713810375249] [Citation(s) in RCA: 91] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can also be highly variable across implant channels. This review discusses evidence that such variability reflects deviations in the electrode-neuron interface, which refers to an implant channel's ability to effectively stimulate the auditory nerve. It is proposed that focused electrical stimulation is ideally suited to assess channel-to-channel irregularities in the electrode-neuron interface. In implant listeners, it is demonstrated that channels with relatively high thresholds, as measured with the tripolar configuration, exhibit broader psychophysical tuning curves and smaller dynamic ranges than channels with relatively low thresholds. Broader tuning implies that frequency-specific information intended for one population of neurons in the cochlea may activate more distant neurons, and a compressed dynamic range could make it more difficult to resolve intensity-based information, particularly in the presence of competing noise. Degradation of both types of cues would negatively affect speech perception.
Collapse
Affiliation(s)
- Julie Arenberg Bierer
- Department of Speech & Hearing Sciences, University of Washington, 1417 NE 42nd Street, Seattle,WA 98105-6246, USA.
| |
Collapse
|
33
|
Effects of stimulation level and electrode pairing on the binaural interaction component of the electrically evoked auditory brain stem response. Ear Hear 2010; 31:457-70. [PMID: 20418771 DOI: 10.1097/aud.0b013e3181d5d9bf] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The purpose of this study was to investigate the effects of stimulation level and electrode pairing on the binaural interaction component (BIC) of the electrically evoked auditory brain stem response (EABR) in Nucleus cochlear implant (CI) users. DESIGN Ten postlingually deafened adult CI users participated in this study. EABRs were measured using loudness balanced, biphasic current pulses presented in the left monaural, right monaural, and bilateral stimulation conditions. BICs were computed based on measures of the EABR obtained for each subject by pairing the electrode 12 (of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The effect of stimulation level on the amplitude of the BIC was investigated by measuring growth functions of the BIC from six subjects. The effect of electrode pairing on the amplitude of the BIC was studied at high stimulation levels in 10 subjects and at low stimulation levels in seven subjects. The high stimulation level was chosen as the 90% point of the subject's dynamic range (DR) or the highest stimulation level in which the electrophysiologic recordings were not contaminated by muscle artifacts. The low stimulation level was chosen as a level that was 10% point of subject's DR higher than the BIC threshold for six of these seven subjects. For one subject, BIC thresholds were not available and the low stimulation level was referred to the 70% point of subject's DR. RESULTS BICs were successfully recorded from all 11 interaural electrode pairs for a majority of subjects tested at both stimulation levels. BIC amplitudes increased with stimulation level. The effect of stimulation level on latencies of the BIC was less robust. At high stimulation levels, BIC amplitudes did not change significantly as the stimulating electrode used in the left ear was systematically varied. When low stimulation levels were used, BIC amplitude was maximal for interaural electrode pairs with similar intracochlear positions and decreased when the offset between interaural electrodes increased. CONCLUSIONS This study demonstrates that stimulation level affects amplitudes of the BIC response. It is possible to record the BIC of the EABR in bilateral CI users even from interaural electrode pairs that have large interaural offsets. This finding suggests that when high-level stimuli are used, there is a broad pattern of current spread within the two cochleae. At lower stimulation levels, the spread of excitation within the cochlea is reduced making the effect of electrode pairing on the amplitude of the BIC more pronounced.
Collapse
|
34
|
Undurraga JA, van Wieringen A, Carlyon RP, Macherey O, Wouters J. Polarity effects on neural responses of the electrically stimulated auditory nerve at different cochlear sites. Hear Res 2010; 269:146-61. [DOI: 10.1016/j.heares.2010.06.017] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2009] [Revised: 06/09/2010] [Accepted: 06/19/2010] [Indexed: 11/16/2022]
|
35
|
Srinivasan AG, Landsberger DM, Shannon RV. Current focusing sharpens local peaks of excitation in cochlear implant stimulation. Hear Res 2010; 270:89-100. [PMID: 20850513 DOI: 10.1016/j.heares.2010.09.004] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2010] [Revised: 08/19/2010] [Accepted: 09/08/2010] [Indexed: 10/19/2022]
Abstract
Cochlear implant (CI) users' spectral resolution is limited by the number of implanted electrodes, interactions between the electrodes, and the underlying neural population. Current steering has been proposed to increase the number of spectral channels beyond the number of physical electrodes, however, electric field interactions may limit CI users' access to current-steered virtual channels (VCs). Current focusing (e.g tripolar stimulation) has been proposed to reduce current spread and thereby reduce interactions. In this study, current steering and current focusing were combined in a four-electrode stimulation pattern, i.e quadrupolar virtual channels (QPVCs). The spread of excitation was measured and compared between QPVC and Monopolar VC (MPVC) stimuli using a forward masking task. Results showed a sharper peak in the excitation pattern and reduced spread of masking for QPVC stimuli. Results from the forward masking study were compared with a previous study measuring VC discrimination ability and showed a weak relationship between spread of excitation and VC discriminability. The results suggest that CI signal processing strategies that utilize both current steering and current focusing might increase CI users' functional spectral resolution by transmitting more channels and reducing channel interactions.
Collapse
Affiliation(s)
- Arthi G Srinivasan
- Department of Communication and Auditory Neuroscience, House Ear Institute, Los Angeles, CA 90057, USA.
| | | | | |
Collapse
|
36
|
Bierer JA, Bierer SM, Middlebrooks JC. Partial tripolar cochlear implant stimulation: Spread of excitation and forward masking in the inferior colliculus. Hear Res 2010; 270:134-42. [PMID: 20727397 DOI: 10.1016/j.heares.2010.08.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2010] [Revised: 07/15/2010] [Accepted: 08/12/2010] [Indexed: 12/01/2022]
Abstract
This study examines patterns of neural activity in response to single biphasic electrical pulses, presented alone or following a forward masking pulse train, delivered by a cochlear implant. Recordings were made along the tonotopic axis of the central nucleus of the inferior colliculus (ICC) in ketamine/xylazine anesthetized guinea pigs. The partial tripolar electrode configuration was used, which provided a systematic way to vary the tonotopic extent of ICC activation between monopolar (broad) and tripolar (narrow) extremes while maintaining the same peak of activation. The forward masking paradigm consisted of a 200 ms masker pulse train (1017 pulses per second) followed 10 ms later by a single-pulse probe stimulus; the current fraction of the probe was set to 0 (monopolar), 1 (tripolar), or 0.5 (hybrid), and the fraction of the masker was fixed at 0.5. Forward masking tuning profiles were derived from the amount of masking current required to just suppress the activity produced by a fixed-level probe. These profiles were sharper for more focused probe configurations, approximating the pattern of neural activity elicited by single (non-masked) pulses. The result helps to bridge the gap between previous findings in animals and recent psychophysical data.
Collapse
|
37
|
Neural response telemetry reconsidered: I. The relevance of ECAP threshold profiles and scaled profiles to cochlear implant fitting. Ear Hear 2010; 31:367-79. [PMID: 20124902 DOI: 10.1097/aud.0b013e3181c9fd86] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE For more than a decade, Neural Response Telemetry (NRT) has provided direct access to the electrically evoked compound action potential (ECAP) as elicited by the Nucleus cochlear implant. When used clinically during fitting, ECAP threshold profiles are applied by shifting the profile to the audible threshold and comfort level boundaries (the T- and C-level profiles, respectively). The resulting profiles, to date, have matched the curvature of the ECAP threshold profile exactly. When compared with psychophysical profiles, previous studies have shown that this approach incurs errors in program levels that are no better than flat or population mean profiles. However, C-level profiles are observed to be flatter than T-level profiles. Accordingly, ECAP threshold profiles are flattened in this study when applied at increasing stimulus levels, and the effectiveness of this approach is evaluated among other methods. DESIGN In phase I, ECAP thresholds (via AutoNRT) and T- and C-levels were measured from 15 adult Nucleus Freedom implantees. Psychophysical levels were measured using pulse train stimuli at six different stimulation rates, spanning 80 to 3500 Hz. The different rates spread T- and C-levels across a range of stimulus levels. At each of these levels, a scaling factor of best fit was calculated such that the shifted ECAP threshold profile, when scaled (0 giving a flat profile, 1 giving an unmodified profile), gave the best fit to the corresponding psychophysical profile. From the 148 such T- and C-level profiles, a single profile scaling model was determined by a simple linear regression. In phase II, the model was tested on data using three separate stimulation rates (250, 900, and 2400 Hz) and 14 additional subjects. The root mean square psychophysical level mismatch of the ECAP threshold profile, the scaled ECAP threshold profile, a flat profile, and a mean population profile was calculated per subject and per stimulation rate, and the differences in the means of these calculations were compared. In phase III, 13 separate subjects evaluated the scaled ECAP-based program during a 2 wk trial, comparing the new program to a flat program and a conventional ECAP-based program with unmodified ECAP threshold profiles. A questionnaire captured their subjective preferences. RESULTS In phase I, the profile scaling model constructed from the data prescribed a flattening of the ECAP threshold profile with increasing mean T- or C-level (in CL units): scale = 1.38 - 0.0043 PsychoMean. In phase II, the scaled ECAP-based profiles were found to fit the psychophysical profiles significantly better in all test configurations (typically of the order of 5% dynamic range) compared with all other profiles. In phase III, 62% of subjects preferred the scaled ECAP-based program, whereas 8% preferred the conventional ECAP-based program, 15% the flat program and 15% had no preference. Analyses of the questionnaires revealed significantly higher ratings for the scaled ECAP-based programs, whereas the conventional ECAP-based programs were not rated differently than the flat programs. CONCLUSIONS The scaled ECAP threshold profile method provides a clinically significant enhancement to ECAP-based fitting methods, confirming the value of the ECAP threshold profile to cochlear implant fitting.
Collapse
|
38
|
Identifying cochlear implant channels with poor electrode-neuron interface: partial tripolar, single-channel thresholds and psychophysical tuning curves. Ear Hear 2010; 31:247-58. [PMID: 20090533 DOI: 10.1097/aud.0b013e3181c7daf4] [Citation(s) in RCA: 108] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The goal of this study was to evaluate the ability of a threshold measure, made with a restricted electrode configuration, to identify channels exhibiting relatively poor spatial selectivity. With a restricted electrode configuration, channel-to-channel variability in threshold may reflect variations in the interface between the electrodes and auditory neurons (i.e., nerve survival, electrode placement, and tissue impedance). These variations in the electrode-neuron interface should also be reflected in psychophysical tuning curve (PTC) measurements. Specifically, it is hypothesized that high single-channel thresholds obtained with the spatially focused partial tripolar (pTP) electrode configuration are predictive of wide or tip-shifted PTCs. DESIGN Data were collected from five cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp., Sylmar, CA). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the pTP configuration for which a fraction of current (sigma) from a center-active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. Forward-masked PTCs were obtained for channels with the highest, lowest, and median tripolar (sigma = 1 or 0.9) thresholds. The probe channel and level were fixed and presented with either the monopolar (sigma = 0) or a more focused pTP (sigma > or = 0.55) configuration. The masker channel and level were varied, whereas the configuration was fixed to sigma = 0.5. A standard, three-interval, two-alternative forced choice procedure was used for thresholds and masked levels. RESULTS Single-channel threshold and variability in threshold across channels systematically increased as the compensating current, sigma, increased and the presumed electrical field became more focused. Across subjects, channels with the highest single-channel thresholds, when measured with a narrow, pTP stimulus, had significantly broader PTCs than the lowest threshold channels. In two subjects, the tips of the tuning curves were shifted away from the probe channel. Tuning curves were also wider for the monopolar probes than with pTP probes for both the highest and lowest threshold channels. CONCLUSIONS These results suggest that single-channel thresholds measured with a restricted stimulus can be used to identify cochlear implant channels with poor spatial selectivity. Channels having wide or tip-shifted tuning characteristics would likely not deliver the appropriate spectral information to the intended auditory neurons, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception.
Collapse
|
39
|
Macherey O, van Wieringen A, Carlyon RP, Dhooge I, Wouters J. Forward-masking patterns produced by symmetric and asymmetric pulse shapes in electric hearing. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 127:326-38. [PMID: 20058980 PMCID: PMC3000474 DOI: 10.1121/1.3257231] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Two forward-masking experiments were conducted with six cochlear implant listeners to test whether asymmetric pulse shapes would improve the place-specificity of stimulation compared to symmetric ones. The maskers were either cathodic-first symmetric biphasic, pseudomonophasic (i.e., with a second anodic phase longer and lower in amplitude than the first phase), or "delayed pseudomonophasic" (identical to pseudomonophasic but with an inter-phase gap) stimuli. In experiment 1, forward-masking patterns for monopolar maskers were obtained by keeping each masker fixed on a middle electrode of the array and measuring the masked thresholds of a monopolar signal presented on several other electrodes. The results were very variable, and no difference between pulse shapes was found. In experiment 2, six maskers were used in a wide bipolar (bipolar+9) configuration: the same three pulse shapes as in experiment 1, either cathodic-first relative to the most apical or relative to the most basal electrode of the bipolar channel. The pseudomonophasic masker showed a stronger excitation proximal to the electrode of the bipolar pair for which the short, high-amplitude phase was anodic. However, no difference was obtained with the symmetric and, more surprisingly, with the delayed pseudomonophasic maskers. Implications for cochlear implant design are discussed.
Collapse
Affiliation(s)
- Olivier Macherey
- ExpORL, Department of Neurosciences, KU Leuven, Herestraat 49, Bus 721, 3000 Leuven, Belgium.
| | | | | | | | | |
Collapse
|
40
|
Excitation patterns of simultaneous and sequential dual-electrode stimulation in cochlear implant recipients. Ear Hear 2009; 30:559-67. [PMID: 19617837 DOI: 10.1097/aud.0b013e3181ab2b6f] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Both simultaneous (SI) and sequential stimulation of intracochlear electrodes can be used to generate pitches that are intermediate to the physical electrodes (PEs). The goal of this study was to compare the spread of neural excitation for SI and sequential dual-electrode stimulation with the spread of neural excitation for the intermediate electrode using electrically evoked compound action potentials. DESIGN Seven Advanced Bionics cochlear implant users with either CII or HiRes 90k implant and HiFocus 1 or HiFocus 1j electrode array participated in this study. A masker-probe subtraction method was used to derive neural excitation patterns for SI nonadjacent dual-electrode stimulation, apical and basal-first sequential nonadjacent dual-electrode stimulation, and the intermediate PE. For apical-first sequential (SEa) stimulation, the masker pulse on the apical electrode immediately preceded the masker pulse on the basal electrode, and vice versa for basal-first sequential stimulation (SEb). The electrodes used for dual-electrode stimulation were separated by an intermediate PE, which represents a spatial distance of approximately 2 mm. Current levels necessary to achieve comfortable loudness were determined for each masker and probe stimulus. During the evoked compound action potential measurements, the masker was fixed in location, whereas the probe was varied across a subset of electrodes in the array. Neural responses were calculated by subtracting the response to the probe from the masked response. RESULTS Neural excitation patterns were normalized to their peak and analyzed in terms of their area and center of gravity. The area and center of gravity for SI nonadjacent dual-electrode stimulation were similar to those of the intermediate PE. In contrast, the area for the two modes of sequential nonadjacent dual-electrode (SEa and SEb) stimulation differed significantly from the intermediate PE. The center of gravity for SEa stimulation also differed significantly from the intermediate PE, whereas there was no significant difference in the center of gravity between SEb stimulation and the intermediate PE. CONCLUSIONS Peripheral neural activation patterns suggest a similar spread of excitation for SI dual-electrode stimulation and the intermediate PE. The spread of excitation associated with sequential dual-electrode stimulation is generally different from the intermediate PE, and it varies depending on the order of the sequential pulses.
Collapse
|
41
|
Klop WMC, Frijns JH, Soede W, Briaire JJ. An objective method to measure electrode independence in cochlear implant patients with a dual-masker forward masking technique. Hear Res 2009; 253:3-14. [DOI: 10.1016/j.heares.2009.03.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2008] [Revised: 03/03/2009] [Accepted: 03/07/2009] [Indexed: 10/21/2022]
|
42
|
Schairer KS, Messersmith J, Jesteadt W. Use of psychometric-function slopes for forward-masked tones to investigate cochlear nonlinearity. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 124:2196-215. [PMID: 19062859 PMCID: PMC2600619 DOI: 10.1121/1.2968686] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2007] [Revised: 07/08/2008] [Accepted: 07/11/2008] [Indexed: 05/24/2023]
Abstract
Schairer et al. [(2003). "Effects of peripheral nonlinearity on psychometric functions for forward-masked tones," J. Acoust. Soc. Am. 133, 1560-1573] demonstrated that cochlear nonlinearity is reflected in psychometric-function (PF) slopes for 4 kHz forward-masked tones. The goals of the current study were to use PF slopes to compare the degree of compression between signal frequencies of 0.25 and 4 kHz in listeners with normal hearing (LNH), and between LNH and listeners with cochlear hearing loss (LHL). Forward-masked thresholds were estimated in LNH and LHL using on- and off-frequency maskers and 0.25 and 4 kHz signals in three experiments. PFs were reconstructed from adaptive-procedure data for each subject in each condition. Trends in PF slopes across conditions suggest comparable compression at 0.25 and 4 kHz, and potentially a wider bandwidth of compression in relative frequency at 0.25 kHz. This is consistent with other recent behavioral studies that revise earlier estimates of less compression at lower frequencies. The preliminary results in LHL demonstrate that PF slopes are abnormally steep at frequencies with HL, but are similar to those for LNH at frequencies with NH. Overall, the results are consistent with the notion that PF slopes reflect degree of cochlear nonlinearity and can be used as an additional measure of compression across frequency.
Collapse
Affiliation(s)
- Kim S Schairer
- Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA.
| | | | | |
Collapse
|
43
|
Psychophysical versus physiological spatial forward masking and the relation to speech perception in cochlear implants. Ear Hear 2008; 29:435-52. [PMID: 18344869 DOI: 10.1097/aud.0b013e31816a0d3d] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The primary goal of this study was to determine if physiological forward masking patterns in cochlear implants are predictive of psychophysical forward masking (PFM) patterns. It was hypothesized that the normalized amount of physiological masking would be positively correlated with the normalized amount of psychophysical masking for different masker-probe electrode separations. A secondary goal was to examine the relation between the spatial forward masking patterns and speech perception performance. It was hypothesized that subjects with less channel interaction overall (either psychophysically or physiologically) would have better speech perception ability because of better spectral resolution. DESIGN Data were collected for 18 adult cochlear implant recipients [N = 9 Clarion CII or HiRes 90K, N = 9 Nucleus 24R(CS)]. Physiological spatial forward masking patterns were obtained with the electrically evoked compound action potential (ECAP) through the implant telemetry system. PFM patterns were obtained using a three-interval, two-alternative forced-choice adaptive procedure. Both measures used a fixed probe electrode with varied masker location. For each subject, spatial forward masking patterns were obtained for three probe electrodes with five masker locations per probe. RESULTS On an individual basis, the correlation between ECAP FM and PFM was strong for 10 subjects (r = 0.68-0.85, p <or= 0.02), moderately strong for two subjects (r = 0.54-0.55, p = 0.06-0.07), and poor for six subjects (r = 0.13-0.45, p > 0.14). Results across subjects and electrodes showed a highly significant correlation between ECAP FM and PFM (r = 0.55, p < 0.0001); the correlation was strongest for basal electrodes. There was no significant correlation between speech perception and ECAP FM or PFM. Subjects whose ECAP FM patterns correlated well with PFM patterns generally had the poorest speech perception and subjects with the poorest correlations had the best speech perception. CONCLUSIONS ECAP FM and PFM patterns correlated well for two-thirds of the subjects. Although the group correlation was statistically significant, ECAP FM patterns only accounted for 30% of the variance in the PFM measures. This suggests that the ECAP measures alone are not sufficient for accurately predicting PFM patterns for individual subjects.
Collapse
|
44
|
Bonham BH, Litvak LM. Current focusing and steering: modeling, physiology, and psychophysics. Hear Res 2008; 242:141-53. [PMID: 18501539 DOI: 10.1016/j.heares.2008.03.006] [Citation(s) in RCA: 115] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2007] [Revised: 03/20/2008] [Accepted: 03/25/2008] [Indexed: 11/25/2022]
Abstract
Current steering and current focusing are stimulation techniques designed to increase the number of distinct perceptual channels available to cochlear implant (CI) users by adjusting currents applied simultaneously to multiple CI electrodes. Previous studies exploring current steering and current focusing stimulation strategies are reviewed, including results of research using computational models, animal neurophysiology, and human psychophysics. Preliminary results of additional neurophysiological and human psychophysical studies are presented that demonstrate the success of current steering strategies in stimulating auditory nerve regions lying between physical CI electrodes, as well as current focusing strategies that excite regions narrower than those stimulated using monopolar configurations. These results are interpreted in the context of perception and speech reception by CI users. Disparities between results of physiological and psychophysical studies are discussed. The differences in stimulation used for physiological and psychophysical studies are hypothesized to contribute to these disparities. Finally, application of current steering and focusing strategies to other types of auditory prostheses is also discussed.
Collapse
Affiliation(s)
- Ben H Bonham
- Saul and Ida Epstein Laboratory, Department of Otolaryngology-HNS, 533 Parnassus Avenue, Box 0526, University of California, San Francisco, CA 94143-0526, USA.
| | | |
Collapse
|
45
|
Nelson DA, Donaldson GS, Kreft H. Forward-masked spatial tuning curves in cochlear implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 123:1522-43. [PMID: 18345841 PMCID: PMC2432425 DOI: 10.1121/1.2836786] [Citation(s) in RCA: 75] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Forward-masked psychophysical spatial tuning curves (fmSTCs) were measured in twelve cochlear-implant subjects, six using bipolar stimulation (Nucleus devices) and six using monopolar stimulation (Clarion devices). fmSTCs were measured at several probe levels on a middle electrode using a fixed-level probe stimulus and variable-level maskers. The average fmSTC slopes obtained in subjects using bipolar stimulation (3.7 dBmm) were approximately three times steeper than average slopes obtained in subjects using monopolar stimulation (1.2 dBmm). Average spatial bandwidths were about half as wide for subjects with bipolar stimulation (2.6 mm) than for subjects with monopolar stimulation (4.6 mm). None of the tuning curve characteristics changed significantly with probe level. fmSTCs replotted in terms of acoustic frequency, using Greenwood's [J. Acoust. Soc. Am. 33, 1344-1356 (1961)] frequency-to-place equation, were compared with forward-masked psychophysical tuning curves obtained previously from normal-hearing and hearing-impaired acoustic listeners. The average tuning characteristics of fmSTCs in electric hearing were similar to the broad tuning observed in normal-hearing and hearing-impaired acoustic listeners at high stimulus levels. This suggests that spatial tuning is not the primary factor limiting speech perception in many cochlear implant users.
Collapse
Affiliation(s)
- David A Nelson
- Clinical Psychoacoustics Laboratory, Department of Otolaryngology, University of Minnesota, MMC396, 420 Delaware Street S.E., Minneapolis, Minnesota 55455, USA.
| | | | | |
Collapse
|
46
|
Macherey O, Carlyon RP, van Wieringen A, Deeks JM, Wouters J. Higher sensitivity of human auditory nerve fibers to positive electrical currents. J Assoc Res Otolaryngol 2008; 9:241-51. [PMID: 18288537 PMCID: PMC2413083 DOI: 10.1007/s10162-008-0112-4] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2007] [Accepted: 01/16/2008] [Indexed: 11/25/2022] Open
Abstract
Most contemporary cochlear implants (CIs) stimulate the auditory nerve with trains of amplitude-modulated, symmetric biphasic pulses. Although both polarities of a pulse can depolarize the nerve fibers and generate action potentials, it remains unknown which of the two (positive or negative) phases has the stronger effect. Understanding the effects of pulse polarity will help to optimize the stimulation protocols and to deliver the most relevant information to the implant listeners. Animal experiments have shown that cathodic (negative) current flows are more effective than anodic (positive) ones in eliciting neural responses, and this finding has motivated the development of novel speech-processing algorithms. In this study, we show electrophysiologically and psychophysically that the human auditory system exhibits the opposite pattern, being more sensitive to anodic stimulation. We measured electrically evoked compound action potentials in CI listeners for phase-separated pulses, allowing us to tease out the responses to each of the two opposite-polarity phases. At an equal stimulus level, the anodic phase yielded the larger response. Furthermore, a measure of psychophysical masking patterns revealed that this polarity difference was still present at higher levels of the auditory system and was therefore not solely due to antidromic propagation of the neural response. This finding may relate to a particular orientation of the nerve fibers relative to the electrode or to a substantial degeneration and demyelination of the peripheral processes. Potential applications to improve CI speech-processing strategies are discussed.
Collapse
Affiliation(s)
- Olivier Macherey
- ExpORL, Department of Neurosciences, Katholieke Universiteit Leuven, O. & N2, Herestraat 49 bus 721, 3000, Leuven, Belgium,
| | | | | | | | | |
Collapse
|
47
|
Cochlear implant electrode configuration effects on activation threshold and tonotopic selectivity. Hear Res 2007; 235:23-38. [PMID: 18037252 DOI: 10.1016/j.heares.2007.09.013] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2007] [Revised: 08/16/2007] [Accepted: 09/14/2007] [Indexed: 11/20/2022]
Abstract
The multichannel design of contemporary cochlear implants (CIs) is predicated on the assumption that each channel activates a relatively restricted and independent sector of the deaf auditory nerve array, just as a sound within a restricted frequency band activates a restricted region of the normal cochlea The independence of CI channels, however, is limited; and the factors that determine their independence, the relative overlap of the activity patterns that they evoke, are poorly understood. In this study, we evaluate the spread of activity evoked by cochlear implant channels by monitoring activity at 16 sites along the tonotopic axis of the guinea pig inferior colliculus (IC). "Spatial tuning curves" (STCs) measured in this way serve as an estimate of activation spread within the cochlea and the ascending auditory pathways. We contrast natural stimulation using acoustic tones with two kinds of electrical stimulation either (1) a loose fitting banded array consisting of a cylindrical silicone elastomer carrier with a linear series of ring contacts; or (2) a space-filling array consisting of a tapered silicone elastomer carrier that is designed to fit snugly into the guinea pig scala tympani with a linear series of ball contacts positioned along it Spatial tuning curves evoked by individual acoustic tones, and by activation of each contact of each array as a monopole, bipole or tripole were recorded. Several channel configurations and a wide range of electrode separations were tested for each array, and their thresholds and selectivity were estimated. The results indicate that the tapered space-filling arrays evoked more restricted activity patterns at lower thresholds than did the banded arrays. Monopolar stimulation (one intracochlear contact activated with an extracochlear return) using either array evoked broad activation patterns that involved the entire recording array at current levels <6dBSL, but at relatively low thresholds. Bi- and tri-polar configurations of both array types evoked more restricted activity patterns, but their thresholds were higher than those of monopolar configurations. Bipolar and tripolar configurations with closely spaced contacts evoked activity patterns that were comparable to those evoked by pure tones. As the spacing of bipolar electrodes was increased (separations >1mm), the activity patterns became broader and evoked patterns with two distinct threshold minima, one associated with each contact.
Collapse
|
48
|
Carlyon RP, Long CJ, Deeks JM, McKay CM. Concurrent sound segregation in electric and acoustic hearing. J Assoc Res Otolaryngol 2007; 8:119-33. [PMID: 17216383 PMCID: PMC2538412 DOI: 10.1007/s10162-006-0068-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2006] [Accepted: 12/04/2006] [Indexed: 10/23/2022] Open
Abstract
We investigated potential cues to sound segregation by cochlear implant (CI) and normal-hearing (NH) listeners. In each presentation interval of experiment 1a, CI listeners heard a mixture of four pulse trains applied concurrently to separate electrodes, preceded by a "probe" applied to a single electrode. In one of these two intervals, which the subject had to identify, the probe electrode was the same as a "target" electrode in the mixture. The pulse train on the target electrode had a higher level than the others in the mixture. Additionally, it could be presented either with a 200-ms onset delay, at a lower rate, or with an asynchrony produced by delaying each pulse by about 5 ms re those on the nontarget electrodes. Neither the rate difference nor the asynchrony aided performance over and above the level difference alone, but the onset delay produced a modest improvement. Experiment 1b showed that two subjects could perform the task using the onset delay alone, with no level difference. Experiment 2 used a method similar to that of experiment 1, but investigated the onset cue using NH listeners. In one condition, the mixture consisted of harmonics 5 to 40 of a 100-Hz fundamental, with the onset of either harmonics 13 to 17 or 26 to 30 delayed re the rest. Performance was modest in this condition, but could be improved markedly by using stimuli containing a spectral gap between the target and nontarget harmonics. The results suggest that (a) CI users are unlikely to use temporal pitch differences between adjacent channels to separate concurrent sounds, and that (b) they can use onset differences between channels, but the usefulness of this cue will be compromised by the spread of excitation along the nerve-fiber array. This deleterious effect of spread-of-excitation can also impair the use of onset cues by NH listeners.
Collapse
Affiliation(s)
- Robert P Carlyon
- MRC Cognition & Brain Sciences Unit, 15 Chaucer Rd, Cambridge, CB2 7EF, England.
| | | | | | | |
Collapse
|