1
|
Lee D, Lewis JD. Inter-Subject Variability in the Dependence of Medial-Olivocochlear Reflex Strength on Noise Bandwidth. Ear Hear 2023; 44:544-557. [PMID: 36477401 DOI: 10.1097/aud.0000000000001302] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/15/2023]
Abstract
OBJECTIVES The objective of the study was to quantify inter-subject variability in the dependence of the medial-olivocochlear reflex (MOCR) on noise bandwidth. Of specific interest was whether inter-subject variability in MOCR dependence on bandwidth explained variability in the MOCR response elicited by wideband noise. DESIGN Thirty-two young adults with normal hearing participated in the study. Click-evoked otoacoustic emissions were measured in the ipsilateral ear with and without noise presented in the contralateral ear. Presentation of contralateral noise served to activate the MOCR. The MOCR was activated using five different noise stimuli with bandwidths ranging from 1- to 5-octaves wide (center frequency of 2 kHz; bandwidth incremented in 1-octave steps). Noise spectral levels (19.6 dB SPL/Hz) were held constant across all bandwidths. MOCR metrics included the normalized-percent change in the otoacoustic emission (OAE), the MOCR-induced OAE magnitude shift, and the MOCR-induced OAE phase shift. Linear mixed-effect models were fit to model the dependence of MOCR-induced OAE magnitude and phase changes on noise bandwidth. The use of a mixed-effect modeling approach allowed for the estimation of subject-specific model parameters that capture on- and off-frequency contributions to the MOCR effects. Regression analysis was performed to evaluate the predictive capacity of subject-specific model parameters on the MOCR response elicited by wideband noise. RESULTS All OAE-based MOCR metrics increased as the noise bandwidth increased from 1- to 5-octaves wide. The dependence of MOCR-induced OAE magnitude and phase shifts on activator bandwidth was well approximated using a linear model with intercept and slope terms. On average, MOCR-induced magnitude and phase shifts increased at a rate of 0.3 dB/octave and 0.01 cycles/octave, respectively, as bandwidth extended beyond the predicted region of OAE generation. A statistically significant random effect of subject was found for both the intercept and slope parameter of each model. Subject-specific slope estimates were statistically significant predictors of a repeated measure of the wideband MOCR response. A higher slope was predictive of larger wideband MOCR effects. CONCLUSIONS MOCR-induced changes to the OAE are greatest when the MOCR is elicited using wideband noise. Variability in the process of spectral integration within the MOCR pathway appears to explain, in part, inter-subject variability in OAE-based estimates of the MOCR response elicited by wideband noise.
Collapse
Affiliation(s)
- Donguk Lee
- Department of Audiology and Speech Pathology, University of Tennessee Health Science Center, Knoxville, Tennessee, USA
| | | |
Collapse
|
2
|
Pacheco D, Rajagopal N, Prieve BA, Nangia S. Joint Profile Characteristics of Long-Latency Transient Evoked and Distortion Otoacoustic Emissions. Am J Audiol 2022; 31:684-697. [PMID: 35862753 DOI: 10.1044/2022_aja-21-00182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE In clinical practice, otoacoustic emissions (OAEs) are interpreted as either "present" or "absent." However, OAEs have the potential to inform about etiology and severity of hearing loss if analyzed in other dimensions. A proposed method uses the nonlinear component of the distortion product OAEs together with stimulus frequency OAEs to construct a joint reflection-distortion profile. The objective of the current study is to determine if joint reflection-distortion profiles can be created using long-latency (LL) components of transient evoked OAEs (TEOAEs) as the reflection-type emission. METHOD LL TEOAEs and the nonlinear distortion OAEs were measured from adult ears. Individual input-output (I/O) functions were created, and OAE level was normalized by dividing by the stimulus level yielding individual gain functions. Peak strength, compression threshold, and OAE level at compression threshold were derived from individual gain functions to create joint reflection-distortion profiles. RESULTS TEOAEs with a poststimulus window starting at 6 ms had I/O functions with compression characteristics similar to LL TEOAE components. The model fit the LL gain functions, which had R 2 > .93, significantly better than the nonlinear distortion OAE gain functions, which had R 2 = .596-.99. Interquartile ranges for joint reflection-distortion profiles were larger for compression threshold and OAE level at compression threshold but smaller for peak strength than those previously published. CONCLUSIONS The gain function fits LL TEOAEs well. Joint reflection-distortion profiles are a promising method that could enhance diagnosis of hearing loss, and use of the LL TEOAE in the profile for peak strength may be important because of narrow interquartile ranges. SUPPLEMENTAL MATERIAL https://doi.org/10.23641/asha.20323593.
Collapse
Affiliation(s)
- Devon Pacheco
- Department of Communication Sciences and Disorders, Syracuse University, NY
| | - Nandhini Rajagopal
- Department of Biomedical and Chemical Engineering, Syracuse University, NY
| | - Beth A Prieve
- Department of Communication Sciences and Disorders, Syracuse University, NY
| | - Shikha Nangia
- Department of Biomedical and Chemical Engineering, Syracuse University, NY
| |
Collapse
|
3
|
Distortion Product Otoacoustic Emission Component Behavior as a Function of Primary Frequency Ratio and Primary Level. Ear Hear 2022; 43:1824-1835. [PMID: 35853351 PMCID: PMC9588520 DOI: 10.1097/aud.0000000000001251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES Distortion product otoacoustic emissions (DPOAEs) are composed of distortion and reflection components. Much is known about the influence of the stimulus frequency ratio (f 2 /f 1 ) on the overall/composite DPOAE level. However, the influence of f 2 /f 1 on individual DPOAE components is not as well examined. The goals of this pilot study were to systematically evaluate the effects of f 2 /f 1 on DPOAE components in clinically normal-hearing young adult ears. To extend the limited reports in the literature, this examination was carried out over an extended frequency range using two stimulus-level combinations. DESIGN DPOAEs were recorded from seven normal-hearing, young adult ears for f 2 frequencies between 0.75 and 16 kHz over a range of f 2 /f 1 using two stimulus-level combinations. The distortion (DPOAE D ) and reflection (DPOAE R ) components were separated using an inverse fast Fourier transform algorithm. Optimal ratios for the composite DPOAE and DPOAE components were determined from smoothed versions of level versus ratio functions in each case. RESULTS The optimal ratio for the composite DPOAE level increased with stimulus level and decreased as a function of frequency above 1 kHz. The optimal ratios for the DPOAE components followed a similar trend, decreasing with increasing frequency. The optimal ratio for DPOAE D was generally higher than that for DPOAE R . The overall level for DPOAE D was greater than that of DPOAE R , both decreasing with increasing frequency. DPOAE R , but not DPOAE D , became unrecordable above the noise floor at the higher frequencies. CONCLUSIONS DPOAE components behave similarly but not identically as a function of f 2 /f 1 . The ear canal DPOAE is generally dominated by DPOAE D . The behavior of DPOAE D as a function of f 2 /f 1 is entirely consistent with known properties of cochlear mechanics. The behavior of DPOAE R is more variable across ears, perhaps reflective of the increased number of parameters that influence its final form. Attempting to use an f 2 /f 1 that would allow a greater bias of the ear canal DPOAE toward one component or the other does not appear to be practical.
Collapse
|
4
|
Charaziak KK, Shera CA. Reflection-Source Emissions Evoked with Clicks and Frequency Sweeps: Comparisons Across Levels. J Assoc Res Otolaryngol 2021; 22:641-658. [PMID: 34606020 DOI: 10.1007/s10162-021-00813-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 08/22/2021] [Indexed: 02/07/2023] Open
Abstract
According to coherent reflection theory, otoacoustic emissions (OAE) evoked with clicks (clicked-evoked, CE) or tones (stimulus frequency, SF) originate via the same mechanism. We test this hypothesis in gerbils by investigating the similarity of CE- and SFOAEs across a wide range of stimulus levels. The results show that OAE transfer functions measured in response to clicks and sweeps have nearly equivalent time-frequency characteristics, particularly at low stimulus levels. At high stimulus levels, the two OAE types are more dissimilar, reflecting the different dynamic properties of the evoking stimulus. At mid to high stimulus levels, time-frequency analysis reveals contributions from at least two OAE source components of varying latencies. Interference between these components explains the emergence of strong spectral microstructure. Time-frequency filtering based on mean basilar-membrane (BM) group delays (τBM) shows that late-latency OAE components (latency ~ 1.6τBM) dominate at low stimulus intensities and exhibit highly compressive growth with increasing stimulus intensity. In contrast, early-latency OAE components (~ 0.7τBM) are small at low stimulus levels but can come to dominate the overall response at higher intensities. Although the properties of long-latency OAEs are consistent with an origin via coherent reflection near the peak of the traveling wave, the generation place and/or mechanisms responsible for the early-latency OAE components warrant further investigation. Because their delay remains in constant proportion to τBM across sound intensity, long-latency OAEs, whether evoked with tones or clicks, can be used to predict characteristics of cochlear processing, such as the sharpness of frequency tuning, even at high stimulus levels.
Collapse
Affiliation(s)
- Karolina K Charaziak
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, CA, USA.
| | - Christopher A Shera
- Caruso Department of Otolaryngology, University of Southern California, Los Angeles, CA, USA.,Department of Physics and Astronomy, University of Southern California, Los Angeles, CA, USA
| |
Collapse
|
5
|
Goodman SS, Boothalingam S, Lichtenhan JT. Medial olivocochlear reflex effects on amplitude growth functions of long- and short-latency components of click-evoked otoacoustic emissions in humans. J Neurophysiol 2021; 125:1938-1953. [PMID: 33625926 DOI: 10.1152/jn.00410.2020] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Functional outcomes of medial olivocochlear reflex (MOCR) activation, such as improved hearing in background noise and protection from noise damage, involve moderate to high sound levels. Previous noninvasive measurements of MOCR in humans focused primarily on otoacoustic emissions (OAEs) evoked at low sound levels. Interpreting MOCR effects on OAEs at higher levels is complicated by the possibility of the middle-ear muscle reflex and by components of OAEs arising from different locations along the length of the cochlear spiral. We overcame these issues by presenting click stimuli at a very slow rate and by time-frequency windowing the resulting click-evoked (CE)OAEs into short-latency (SL) and long-latency (LL) components. We characterized the effects of MOCR on CEOAE components using multiple measures to more comprehensively assess these effects throughout much of the dynamic range of hearing. These measures included CEOAE amplitude attenuation, equivalent input attenuation, phase, and slope of growth functions. Results show that MOCR effects are smaller on SL components than LL components, consistent with SL components being generated slightly basal of the characteristic frequency region. Amplitude attenuation measures showed the largest effects at the lowest stimulus levels, but slope change and equivalent input attenuation measures did not decrease at higher stimulus levels. These latter measures are less commonly reported and may provide insight into the variability in listening performance and noise susceptibility seen across individuals.NEW & NOTEWORTHY The auditory efferent system, operating at moderate to high sound levels, may improve hearing in background noise and provide protection from noise damage. We used otoacoustic emissions to measure these efferent effects across a wide range of sound levels and identified level-dependent and independent effects. Previous reports have focused on level-dependent measures. The level-independent effects identified here may provide new insights into the functional relevance of auditory efferent activity in humans.
Collapse
Affiliation(s)
- Shawn S Goodman
- Department of Communication Sciences and Disorders, University of Iowa, Iowa City, Iowa
| | - Sriram Boothalingam
- Department of Communication Sciences and Disorders, Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin
| | - Jeffery T Lichtenhan
- Department of Otolaryngology, Washington University School of Medicine in St. Louis, St. Louis, Missouri
| |
Collapse
|
6
|
Vencovský V, Vetešník A, Gummer AW. Nonlinear reflection as a cause of the short-latency component in stimulus-frequency otoacoustic emissions simulated by the methods of compression and suppression. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:3992. [PMID: 32611132 DOI: 10.1121/10.0001394] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Accepted: 05/22/2020] [Indexed: 06/11/2023]
Abstract
Stimulus-frequency otoacoustic emissions (SFOAEs) are generated by coherent reflection of forward traveling waves by perturbations along the basilar membrane. The strongest wavelets are backscattered near the place where the traveling wave reaches its maximal amplitude (tonotopic place). Therefore, the SFOAE group delay might be expected to be twice the group delay estimated in the cochlear filters. However, experimental data have yielded steady-state SFOAE components with near-zero latency. A cochlear model is used to show that short-latency SFOAE components can be generated due to nonlinear reflection of the compressor or suppressor tones used in SFOAE measurements. The simulations indicate that suppressors produce more pronounced short-latency components than compressors. The existence of nonlinear reflection components due to suppressors can also explain why SFOAEs can still be detected when suppressors are presented more than half an octave above the probe-tone frequency. Simulations of the SFOAE suppression tuning curves showed that phase changes in the SFOAE residual as the suppressor frequency increases are mostly determined by phase changes of the nonlinear reflection component.
Collapse
Affiliation(s)
- Václav Vencovský
- Department of Radioelectronics, Czech Technical University in Prague, Technická 2, 166 27 Prague, Czech Republic
| | - Aleš Vetešník
- Department of Nuclear Chemistry, Czech Technical University in Prague, Břehová 7, 115 19 Prague, Czech Republic
| | - Anthony W Gummer
- Department of Otolaryngology, Section of Physiological Acoustics and Communication, Eberhard-Karls-University Tübingen, Elfriede-Aulhorn-Strasse 5, 72076 Tübingen, Germany
| |
Collapse
|
7
|
Mishra SK. The role of efferents in human auditory development: efferent inhibition predicts frequency discrimination in noise for children. J Neurophysiol 2020; 123:2437-2448. [PMID: 32432503 DOI: 10.1152/jn.00136.2020] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The descending corticofugal fibers originate from the auditory cortex and exert control on the periphery via the olivocochlear efferents. Medial efferents are thought to enhance the discriminability of transient sounds in background noise. In addition, the observation of deleterious long-term effects of efferent sectioning on the response properties of auditory nerve fibers in neonatal cats supports an efferent-mediated control of normal development. However, the role of the efferent system in human hearing remains unclear. The objective of the present study was to test the hypothesis that the medial efferents are involved in the development of frequency discrimination in noise. The hypothesis was examined with a combined behavioral and physiological approach. Frequency discrimination in noise and efferent inhibition were measured in 5- to 12-yr-old children (n = 127) and young adults (n = 37). Medial efferent strength was noninvasively assayed with a rigorous otoacoustic emission protocol. Results revealed an age-mediated relationship between efferent inhibition and frequency discrimination in noise. Efferent inhibition strongly predicted frequency discrimination in noise for younger children (5-9 yr). However, for older children (>9 yr) and adults, efferent inhibition was not related to frequency discrimination in noise. These findings support the role of efferents in the development of hearing-in-noise in humans; specifically, younger children compared with older children and adults are relatively more dependent on efferent inhibition for extracting relevant cues in noise. Additionally, the present findings caution against postulating an oversimplified relationship between efferent inhibition and measures of auditory perception in humans.NEW & NOTEWORTHY Despite several decades of research, the functional role of medial olivocochlear efferents in humans remains controversial and is thought to be insignificant. Here it is shown that medial efferent inhibition strongly predicts frequency discrimination in noise for younger children but not for older children and adults. Young children are relatively more dependent on the efferent system for listening-in-noise. This study highlights the role of the efferent system in hearing-in-noise during childhood development.
Collapse
Affiliation(s)
- Srikanta K Mishra
- Department of Communication Sciences and Disorders, The University of Texas Rio Grande Valley, Edinburg, Texas.,Department of Communication Disorders, New Mexico State University, Las Cruces, New Mexico
| |
Collapse
|
8
|
Lewis JD, Mashburn A, Lee D. Jittering stimulus onset attenuates short-latency, synchronized-spontaneous otoacoustic emission energy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:1504. [PMID: 32237807 DOI: 10.1121/10.0000848] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 02/14/2020] [Indexed: 06/11/2023]
Abstract
Synchronized-spontaneous otoacoustic emissions (SSOAEs) are slow-decaying otoacoustic emissions (OAEs) that persist up to several hundred milliseconds following presentation of a transient stimulus. If the inter-stimulus interval is sufficiently short, SSOAEs will contaminate the stimulus window of the adjacent epoch. In medial-olivocochlear reflex (MOCR) assays, SSOAE contamination can present as a change in the stimulus between quiet and noise conditions, since SSOAEs are sensitive to MOCR activation. Traditionally, a change in the stimulus between MOCR conditions implicates acoustic reflex activation by the contralateral noise; however, this interpretation is potentially confounded by SSOAEs. This study examined the utility of jittering stimulus onset to desynchronize and cancel short-latency SSOAE energy. Transient-evoked (TE) OAEs and SSOAEs were measured from 39 subjects in contralateral-quiet and -noise conditions. Clicks were presented at fixed and quasi-random intervals (by introducing up to 8 ms of jitter). For the fixed-interval condition, spectral differences in the stimulus window between quiet and noise conditions mirrored those in the SSOAE analysis window, consistent with SSOAE contamination. In contrast, spectral differences stemming from SSOAEs were attenuated and/or absent in the stimulus window for the jitter conditions. The use of jitter did not have a statistically significant effect on either TEOAE level or the estimated MOCR.
Collapse
Affiliation(s)
- James D Lewis
- Department of Audiology and Speech Pathology, University of Tennessee Health Science Center, Knoxville, Tennessee 37996, USA
| | - Amy Mashburn
- Department of Audiology and Speech Pathology, University of Tennessee Health Science Center, Knoxville, Tennessee 37996, USA
| | - Donguk Lee
- Department of Audiology and Speech Pathology, University of Tennessee Health Science Center, Knoxville, Tennessee 37996, USA
| |
Collapse
|
9
|
The Effect of Otoacoustic Emission Stimulus Level on the Strength and Detectability of the Medial Olivocochlear Reflex. Ear Hear 2019; 40:1391-1403. [DOI: 10.1097/aud.0000000000000719] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Mishra SK, Biswal M, Amatya A. Efferent-induced alterations in distortion and reflection otoacoustic emissions in children. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:640. [PMID: 29495742 PMCID: PMC5798993 DOI: 10.1121/1.5022793] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Revised: 12/30/2017] [Accepted: 01/13/2018] [Indexed: 06/08/2023]
Abstract
The medial olivocochlear efferent fibers control outer hair cell responses and inhibit the cochlear-amplifier gain. Measuring efferent function is both theoretically and clinically relevant. In humans, medial efferent inhibition can be assayed via otoacoustic emissions (OAEs). OAEs arise by two fundamentally different mechanisms-nonlinear distortion and coherent reflection. Distortion and reflection emissions are typically applied in isolation for studying the efferent inhibition. Such an approach inadvertently assumes that efferent-induced shifts in distortion and reflection emissions provide redundant information. In this study, efferent-induced shifts in distortion and reflection emissions (click-evoked and stimulus frequency OAEs) were measured in the same subjects-5- to 10-yr-old children. Consistent with the OAE generation theory, efferent-induced shifts in distortion and reflection emissions did not correlate, whereas the two reflection emission shifts correlated. This suggests that using either OAE types provides fragmented information on efferent inhibition and highlights the need to use both distortion and reflection emissions for describing efferent effects.
Collapse
Affiliation(s)
- Srikanta K Mishra
- Department of Communication Disorders, New Mexico State University, Las Cruces, New Mexico 88003, USA
| | - Milan Biswal
- Department of Communication Disorders, New Mexico State University, Las Cruces, New Mexico 88003, USA
| | - Anup Amatya
- Department of Public Health Sciences, New Mexico State University, Las Cruces, New Mexico 88003, USA
| |
Collapse
|
11
|
Lewis JD. Comparison of Transient-Evoked Otoacoustic Emission Waveforms and Latencies Between Nonlinear Measurement Techniques. ACTA ACUST UNITED AC 2017. [DOI: 10.1044/persp2.sig6.4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The nonlinear differential technique is commonly used to remove stimulus artifact when measuring transient-evoked otoacoustic emissions (TEOAE). However, to ensure removal of stimulus artifact, the initial 2.5-ms of the sound pressure recording must be discarded. Discarding this portion of the response precludes measurement of TEOAE energy above approximately 5 kHz and may limit measurement of shorter-latency TEOAE components below 5 kHz. The contribution from short-latency components influences the overall latency of the emission, including its dependence on frequency and stimulus level. The double source, double-evoked technique provides an alternative means to eliminate stimulus energy from the TEOAE and permits retention of the entire response. This study describes the effect of measurement technique on TEOAE waveforms and latencies. TEOAEs were measured in 26 normal hearing subjects using the nonlinear differential and double source, double-evoked techniques. The nonlinear differential technique limited measurement of short-latency TEOAE components at frequencies as low as ~3 kHz. Loss of these components biased TEOAE latencies to later moments in time and reduced the dependence of latency on stimulus level and frequency. In studies investigating TEOAE latency, the double source, double-evoked technique is recommended as it permits measurement of the both long- and short-latency components of the TEOAE.
Collapse
Affiliation(s)
- James D. Lewis
- Department of Audiology and Speech Pathology, University of Tennessee Health Science Center Knoxville, TN
| |
Collapse
|
12
|
Liu YW, Liu TC. Quasilinear reflection as a possible mechanism for suppressor-induced otoacoustic emission. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:4193. [PMID: 28040016 DOI: 10.1121/1.4968879] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A frequency-domain iterative approach is developed to compute the change in characteristic impedance in the cochlea due to the presence of a suppressor tone. Based on this approach, a small transient wave passing by the best place (BP) of the suppressor is predicted to be partially reflected because of the suppressor-induced impedance variation. This computational approach is tested on a nonlinear model of cochlear mechanics [Liu, J. Acoust. Soc. Am. 136, 1788-1796 (2014)]. When a 9-kHz suppressor at 60 dB sound pressure level is delivered to the model, the characteristic impedance decreases by ∼20% near its BP. This localized impedance mismatch causes a forward-going wave at 4 kHz to reflect partially, and the magnitude of the reflected component is about -18 dB relative to the forward-going component near the stapes. The reflected components eventually emit from the cochlea to the ear canal, and the predicted amplitude of tone-burst evoked otoacoustic emissions (OAEs) agrees well with time-domain simulation. The present results suggest that, while the "suppressor" is meant to suppress the OAEs in experiments, its very presence might create an otherwise non-existing emission component via nonlinear scattering when its frequency is higher than that of the probe.
Collapse
Affiliation(s)
- Yi-Wen Liu
- Department of Electrical Engineering, National Tsing Hua University, Hsinchu 300, Taiwan
| | - Tzu-Chi Liu
- Department of Electrical Engineering, National Tsing Hua University, Hsinchu 300, Taiwan
| |
Collapse
|
13
|
Dewey JB, Dhar S. Profiles of Stimulus-Frequency Otoacoustic Emissions from 0.5 to 20 kHz in Humans. J Assoc Res Otolaryngol 2016; 18:89-110. [PMID: 27681700 DOI: 10.1007/s10162-016-0588-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Accepted: 09/09/2016] [Indexed: 02/07/2023] Open
Abstract
The characteristics of human otoacoustic emissions (OAEs) have not been thoroughly examined above the standard audiometric frequency range (>8 kHz). This is despite the fact that deterioration of cochlear function often starts at the basal, high-frequency end of the cochlea before progressing apically. Here, stimulus-frequency OAEs (SFOAEs) were obtained from 0.5 to 20 kHz in 23 young, audiometrically normal female adults and three individuals with abnormal audiograms, using a low-to-moderate probe level of 36 dB forward pressure level (FPL). In audiometrically normal ears, SFOAEs were measurable at frequencies approaching the start of the steeply sloping high-frequency portion of the audiogram (∼12-15 kHz), though their amplitudes often declined substantially above ∼7 kHz, rarely exceeding 0 dB SPL above 8 kHz. This amplitude decline was typically abrupt and occurred at a frequency that was variable across subjects and not strongly related to the audiogram. In contrast, certain ears with elevated mid-frequency thresholds but regions of normal high-frequency sensitivity could possess surprisingly large SFOAEs (>10 dB SPL) above 7 kHz. When also measured, distortion-product OAEs (DPOAEs) usually remained stronger at higher stimulus frequencies and mirrored the audiogram more closely than SFOAEs. However, the high-frequency extent of SFOAE and DPOAE responses was similar when compared as a function of the response frequency, suggesting that middle ear transmission may be a common limiting factor at high frequencies. Nevertheless, cochlear factors are more likely responsible for complexities observed in high-frequency SFOAE spectra, such as abrupt amplitude changes and narrowly defined response peaks above 10 kHz, as well as the large responses in abnormal ears. These factors may include altered cochlear reflectivity due to subtle damage or the reduced spatial extent of the SFOAE generation region at the cochlear base. The use of higher probe levels is necessary to further evaluate the characteristics and potential utility of high-frequency SFOAE measurements.
Collapse
Affiliation(s)
- James B Dewey
- Roxelyn and Richard Pepper Department of Communication Sciences and Disorders, Northwestern University, 2240 Campus Drive, Evanston, IL, 60208, USA.
- Department of Otolaryngology-Head & Neck Surgery, Stanford University, 300 Pasteur Drive, Stanford, CA, 94305, USA.
| | - Sumitrajit Dhar
- Roxelyn and Richard Pepper Department of Communication Sciences and Disorders, Northwestern University, 2240 Campus Drive, Evanston, IL, 60208, USA
- Knowles Hearing Center, Northwestern University, 2240 Campus Drive, Evanston, IL, 60208, USA
| |
Collapse
|
14
|
Keefe DH, Feeney MP, Hunter LL, Fitzpatrick DF. Comparisons of transient evoked otoacoustic emissions using chirp and click stimuli. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:1949. [PMID: 27914441 PMCID: PMC5392097 DOI: 10.1121/1.4962532] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Transient-evoked otoacoustic emission (TEOAE) responses (0.7-8 kHz) were measured in normal-hearing adult ears using click stimuli and chirps whose local frequency increased or decreased linearly with time over the stimulus duration. Chirp stimuli were created by allpass filtering a click with relatively constant incident pressure level over frequency. Chirp TEOAEs were analyzed as a nonlinear residual signal by inverse allpass filtering each chirp response into an equivalent click response. Multi-window spectral and temporal averaging reduced noise levels compared to a single-window average. Mean TEOAE levels using click and chirp stimuli were similar with respect to their standard errors in adult ears. TEOAE group delay, group spread, instantaneous frequency, and instantaneous bandwidth were similar overall for chirp and click conditions, except for small differences showing nonlinear interactions differing across stimulus conditions. These results support the theory of a similar generation mechanism on the basilar membrane for both click and chirp conditions based on coherent reflection within the tonotopic region. TEOAE temporal fine structure was invariant across changes in stimulus level, which is analogous to the intensity invariance of click-evoked basilar-membrane displacement data.
Collapse
Affiliation(s)
- Douglas H Keefe
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - M Patrick Feeney
- National Center for Rehabilitative Auditory Research, Department of Veterans Affairs, Portland Health Care System, 3710 SW US Veterans Hospital Road, Portland, Oregon 97239, USA
| | - Lisa L Hunter
- Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, Ohio 45229, USA
| | - Denis F Fitzpatrick
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| |
Collapse
|
15
|
Mishra SK, Dinger Z. Influence of medial olivocochlear efferents on the sharpness of cochlear tuning estimates in children. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:1060. [PMID: 27586737 DOI: 10.1121/1.4960550] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The present study objectively quantified the efferent-induced changes in the sharpness of cochlear tuning estimates and compared these alterations in cochlear tuning between adults and children. Click evoked otoacoustic emissions with and without contralateral broadband noise were recorded from 15 young adults and 14 children aged between 5 and 10 yrs. Time-frequency distributions of click evoked otoacoustic emissions were obtained via the S-transform, and the otoacoustic emission latencies were used to estimate the sharpness of cochlear tuning. Contralateral acoustic stimulation caused a significant reduction in the sharpness of cochlear tuning estimates in the low to mid frequency region, but had no effect in the higher frequencies (3175 and 4000 Hz). The magnitude of efferent-induced changes in cochlear tuning estimates was similar between adults and children. The current evidence suggests that the stimulation of the medial olivocochlear efferent neurons causes similar alterations in cochlear frequency selectivity in adults and children.
Collapse
Affiliation(s)
- Srikanta K Mishra
- Department of Special Education/Communication Disorders, New Mexico State University, Las Cruces, New Mexico 88003-8001, USA
| | - Zoë Dinger
- Department of Special Education/Communication Disorders, New Mexico State University, Las Cruces, New Mexico 88003-8001, USA
| |
Collapse
|
16
|
Mishra SK, Biswal M. Time–frequency decomposition of click evoked otoacoustic emissions in children. Hear Res 2016; 335:161-178. [DOI: 10.1016/j.heares.2016.03.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Revised: 02/25/2016] [Accepted: 03/07/2016] [Indexed: 02/07/2023]
|
17
|
Within- and Across-Subject Variability of Repeated Measurements of Medial Olivocochlear-Induced Changes in Transient-Evoked Otoacoustic Emissions. Ear Hear 2016; 37:e72-84. [DOI: 10.1097/aud.0000000000000244] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
18
|
Berezina-Greene MA, Guinan JJ. Stimulus Frequency Otoacoustic Emission Delays and Generating Mechanisms in Guinea Pigs, Chinchillas, and Simulations. J Assoc Res Otolaryngol 2015; 16:679-94. [PMID: 26373935 DOI: 10.1007/s10162-015-0543-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Accepted: 08/30/2015] [Indexed: 11/30/2022] Open
Abstract
According to coherent reflection theory (CRT), stimulus frequency otoacoustic emissions (SFOAEs) arise from cochlear irregularities coherently reflecting energy from basilar membrane motion within the traveling-wave peak. This reflected energy arrives in the ear canal predominantly with a single delay at each frequency. However, data from humans and animals indicate that (1) SFOAEs can have multiple delay components, (2) low-frequency SFOAE delays are too short to be accounted for by CRT, and (3) "SFOAEs" obtained with a 2nd ("suppressor") tone ≥2 octaves above the probe tone have been interpreted as arising from the area basal to the region of cochlear amplification. To explore these issues, we collected SFOAEs by the suppression method in guinea pigs and time-frequency analyzed these data, simulated SFOAEs, and published chinchilla SFOAEs. Time-frequency analysis revealed that most frequencies showed only one SFOAE delay component while other frequencies had multiple components including some with short delays. We found no systematic patterns in the occurrence of multiple delay components. Using a cochlear model that had significant basilar membrane motion only in the peak region of the traveling wave, simulated SFOAEs had single and multiple delay components similar to the animal SFOAEs. This result indicates that multiple components (including ones with short delays) can originate from cochlear mechanical irregularities in the SFOAE peak region and are not necessarily indicative of SFOAE sources in regions ≥2 octaves basal of the SFOAE peak region. We conclude that SFOAEs obtained with suppressors close to the probe frequency provide information primarily about the mechanical response in the region that receives amplification, and we attribute the too-short SFOAE delays at low frequencies to distortion-source SFOAEs and coherent reflection from multiple cochlear motions. Our findings suggest that CRT needs revision to include reflections from multiple motions in the cochlear apex.
Collapse
Affiliation(s)
- Maria A Berezina-Greene
- Eaton-Peabody Lab, Mass. Eye and Ear Infirmary, 243 Charles St, Boston, MA, 02114, USA. .,Harvard-MIT HST Speech and Hearing Bioscience and Technology Program, Cambridge, MA, USA.
| | - John J Guinan
- Eaton-Peabody Lab, Mass. Eye and Ear Infirmary, 243 Charles St, Boston, MA, 02114, USA. .,Harvard-MIT HST Speech and Hearing Bioscience and Technology Program, Cambridge, MA, USA. .,Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
19
|
Killan EC, Lutman ME, Thyer NJ. Simultaneous suppression of tone burst-evoked otoacoustic emissions: Two and three-tone burst combinations. Hear Res 2015; 327:28-34. [PMID: 25959270 DOI: 10.1016/j.heares.2015.04.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Revised: 04/23/2015] [Accepted: 04/28/2015] [Indexed: 11/17/2022]
Abstract
Previous investigations have shown that components of a tone burst-evoked otoacoustic emission (TBOAE) evoked by a 1 kHz tone burst (TB1) can be suppressed by the simultaneous presence of a 2 kHz tone burst (TB2) or a pair of tone bursts at 2 and 3 kHz (TB2 and TB3 respectively). No previous study has measured this "simultaneous suppression of TBOAEs" for both TB2 alone and TB2 and TB3 from the same ears, so that the effect of the additional presence of TB3 on suppression caused by TB2 is not known. In simple terms, three outcomes are possible; suppression increases, suppression is reduced or suppression is not affected. Comparison of previously reported simultaneous suppression data suggests TB3 causes a reduction in suppression, though it is not clear if this is a genuine effect or simply reflects methodological and ear differences between studies. This issue has implications for previously proposed mechanisms of simultaneous suppression of TBOAEs and the interpretation of clinical data, and is clarified by the present study. Simultaneous suppression of TBOAEs was measured for TB1 and TB2 as well as TB1, TB2 and TB3 at 50, 60 and 70 dB p.e. SPL from nine normal human ears. Results showed no significant difference between mean suppression obtained for the two and three-tone burst combinations, indicating the reduction of suppression inferred from comparison of previous data is likely a result of methodological and ear differences rather than a genuine effect.
Collapse
Affiliation(s)
| | - Mark E Lutman
- Institute of Sound and Vibration Research, University of Southampton, UK
| | | |
Collapse
|
20
|
Boothalingam S, Purcell DW. Influence of the stimulus presentation rate on medial olivocochlear system assays. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:724-32. [PMID: 25698007 DOI: 10.1121/1.4906250] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Click evoked otoacoustic emissions (CEOAEs) are commonly used both in research and clinics to assay the medial olivocochlear system (MOC). Clicks presented at rates >50 Hz in the contralateral ear have previously been reported to evoke contralateral MOC activity. However, in typical MOC assays, clicks are presented in the ipsilateral ear in conjunction with MOC elicitor (noise) in the contralateral ear. The effect of click rates in such an arrangement is currently unknown. A forward masking paradigm was used to emulate typical MOC assays to elucidate the influence of ipsilateral click presentation rates on MOC inhibition of CEOAEs in 28 normal hearing adults. Influence of five click rates (20.83, 25, 31.25, 41.67, and 62.5 Hz) presented at 55 dB peSPL was tested. Results indicate that click rates as low as 31.25 Hz significantly enhance contralateral MOC inhibition, possibly through the activation of ipsilateral and binaural MOC neurons with potential contributions from the middle ear muscle reflex. Therefore, click rates ≤25 Hz are recommended for use in MOC assays, at least for 55 dB peSPL click level.
Collapse
Affiliation(s)
- Sriram Boothalingam
- National Centre for Audiology, Western University, London, Ontario N6G 1H1, Canada
| | - David W Purcell
- National Centre for Audiology, Western University, London, Ontario N6G 1H1, Canada
| |
Collapse
|