1
|
Guérit F, Harland AJ, Richardson ML, Gransier R, Middlebrooks JC, Wouters J, Carlyon RP. Electrophysiological and Psychophysical Measures of Temporal Pitch Sensitivity in Normal-hearing Listeners. J Assoc Res Otolaryngol 2023; 24:47-65. [PMID: 36471208 PMCID: PMC9971391 DOI: 10.1007/s10162-022-00879-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Accepted: 11/17/2022] [Indexed: 12/12/2022] Open
Abstract
To obtain combined behavioural and electrophysiological measures of pitch perception, we presented harmonic complexes, bandpass filtered to contain only high-numbered harmonics, to normal-hearing listeners. These stimuli resemble bandlimited pulse trains and convey pitch using a purely temporal code. A core set of conditions consisted of six stimuli with baseline pulse rates of 94, 188 and 280 pps, filtered into a HIGH (3365-4755 Hz) or VHIGH (7800-10,800 Hz) region, alternating with a 36% higher pulse rate. Brainstem and cortical processing were measured using the frequency following response (FFR) and auditory change complex (ACC), respectively. Behavioural rate change difference limens (DLs) were measured by requiring participants to discriminate between a stimulus that changed rate twice (up-down or down-up) during its 750-ms presentation from a constant-rate pulse train. FFRs revealed robust brainstem phase locking whose amplitude decreased with increasing rate. Moderate-sized but reliable ACCs were obtained in response to changes in purely temporal pitch and, like the psychophysical DLs, did not depend consistently on the direction of rate change or on the pulse rate for baseline rates between 94 and 280 pps. ACCs were larger and DLs lower for stimuli in the HIGH than in the VHGH region. We argue that the ACC may be a useful surrogate for behavioural measures of rate discrimination, both for normal-hearing listeners and for cochlear-implant users. We also showed that rate DLs increased markedly when the baseline rate was reduced to 48 pps, and compared the behavioural and electrophysiological findings to recent cat data obtained with similar stimuli and methods.
Collapse
Affiliation(s)
- François Guérit
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - Andrew J Harland
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - Matthew L Richardson
- Department of Otolaryngology, University of California at Irvine, Irvine, CA, USA
| | | | - John C Middlebrooks
- Department of Otolaryngology, University of California at Irvine, Irvine, CA, USA
- Department of Neurobiology and Behavior, University of California at Irvine, Irvine, CA, USA
- Department of Cognitive Sciences, University o f California at Irvine, Irvine, CA, USA
- Department of Biomedical Engineering, University of California at Irvine, Irvine, CA, USA
| | - Jan Wouters
- Department of Neurosciences, ExpORL, Leuven, Belgium
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England.
| |
Collapse
|
2
|
Guérit F, Middlebrooks JC, Richardson ML, Arneja A, Harland AJ, Gransier R, Wouters J, Carlyon RP. Tonotopic Selectivity in Cats and Humans: Electrophysiology and Psychophysics. J Assoc Res Otolaryngol 2022; 23:513-534. [PMID: 35697952 PMCID: PMC9437197 DOI: 10.1007/s10162-022-00851-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 05/02/2022] [Indexed: 01/06/2023] Open
Abstract
We describe a scalp-recorded measure of tonotopic selectivity, the "cortical onset response" (COR) and compare the results between humans and cats. The COR results, in turn, were compared with psychophysical masked-detection thresholds obtained using similar stimuli and obtained from both species. The COR consisted of averaged responses elicited by 50-ms tone-burst probes presented at 1-s intervals against a continuous noise masker. The noise masker had a bandwidth of 1 or 1/8th octave, geometrically centred on 4000 Hz for humans and on 8000 Hz for cats. The probe frequency was either - 0.5, - 0.25, 0, 0.25 or 0.5 octaves re the masker centre frequency. The COR was larger for probe frequencies more distant from the centre frequency of the masker, and this effect was greater for the 1/8th-octave than for the 1-octave masker. This pattern broadly reflected the masked excitation patterns obtained psychophysically with similar stimuli in both species. However, the positive signal-to-noise ratio used to obtain reliable COR measures meant that some aspects of the data differed from those obtained psychophysically, in a way that could be partly explained by the upward spread of the probe's excitation pattern. Our psychophysical measurements also showed that the auditory filter width obtained at 8000 Hz using notched-noise maskers was slightly wider in cat than previous measures from humans. We argue that although conclusions from COR measures differ in some ways from conclusions based on psychophysics, the COR measures provide an objective, noninvasive, valid measure of tonotopic selectivity that does not require training and that may be applied to acoustic and cochlear-implant experiments in humans and laboratory animals.
Collapse
Affiliation(s)
- Francois Guérit
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - John C. Middlebrooks
- grid.266093.80000 0001 0668 7243Department of Otolaryngology, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Neurobiology and Behavior, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Cognitive Sciences, University of California at Irvine, Irvine, CA USA
- grid.266093.80000 0001 0668 7243Department of Biomedical Engineering, University of California at Irvine, Irvine, CA USA
| | - Matthew L. Richardson
- grid.266093.80000 0001 0668 7243Department of Otolaryngology, University of California at Irvine, Irvine, CA USA
| | - Akshat Arneja
- grid.266093.80000 0001 0668 7243Department of Cognitive Sciences, University of California at Irvine, Irvine, CA USA
| | - Andrew J. Harland
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - Robin Gransier
- Dept. of Neurosciences, ExpORL, Leuven, Louvain, KU Belgium
| | - Jan Wouters
- Dept. of Neurosciences, ExpORL, Leuven, Louvain, KU Belgium
| | - Robert P. Carlyon
- grid.5335.00000000121885934Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| |
Collapse
|
3
|
Richardson ML, Guérit F, Gransier R, Wouters J, Carlyon RP, Middlebrooks JC. Temporal Pitch Sensitivity in an Animal Model: Psychophysics and Scalp Recordings : Temporal Pitch Sensitivity in Cat. J Assoc Res Otolaryngol 2022; 23:491-512. [PMID: 35668206 PMCID: PMC9437162 DOI: 10.1007/s10162-022-00849-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 04/11/2022] [Indexed: 01/28/2023] Open
Abstract
Cochlear implant (CI) users show limited sensitivity to the temporal pitch conveyed by electric stimulation, contributing to impaired perception of music and of speech in noise. Neurophysiological studies in cats suggest that this limitation is due, in part, to poor transmission of the temporal fine structure (TFS) by the brainstem pathways that are activated by electrical cochlear stimulation. It remains unknown, however, how that neural limit might influence perception in the same animal model. For that reason, we developed non-invasive psychophysical and electrophysiological measures of temporal (i.e., non-spectral) pitch processing in the cat. Normal-hearing (NH) cats were presented with acoustic pulse trains consisting of band-limited harmonic complexes that simulated CI stimulation of the basal cochlea while removing cochlear place-of-excitation cues. In the psychophysical procedure, trained cats detected changes from a base pulse rate to a higher pulse rate. In the scalp-recording procedure, the cortical-evoked acoustic change complex (ACC) and brainstem-generated frequency following response (FFR) were recorded simultaneously in sedated cats for pulse trains that alternated between the base and higher rates. The range of perceptual sensitivity to temporal pitch broadly resembled that of humans but was shifted to somewhat higher rates. The ACC largely paralleled these perceptual patterns, validating its use as an objective measure of temporal pitch sensitivity. The phase-locked FFR, in contrast, showed strong brainstem encoding for all tested pulse rates. These measures demonstrate the cat's perceptual sensitivity to pitch in the absence of cochlear-place cues and may be valuable for evaluating neural mechanisms of temporal pitch perception in the feline animal model of stimulation by a CI or novel auditory prostheses.
Collapse
Affiliation(s)
- Matthew L Richardson
- Department of Otolaryngology, Center for Hearing Research, University of California at Irvine, Irvine, CA, USA.
| | - François Guérit
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK
| | - Robin Gransier
- Department of Neurosciences, ExpORL, KU Leuven, Leuven, Belgium
| | - Jan Wouters
- Department of Neurosciences, ExpORL, KU Leuven, Leuven, Belgium
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK
| | - John C Middlebrooks
- Department of Otolaryngology, Center for Hearing Research, University of California at Irvine, Irvine, CA, USA
- Departments of Neurobiology & Behavior, Biomedical Engineering, Cognitive Sciences, University of California at Irvine, Irvine, CA, USA
| |
Collapse
|
4
|
Parida S, Heinz MG. Noninvasive Measures of Distorted Tonotopic Speech Coding Following Noise-Induced Hearing Loss. J Assoc Res Otolaryngol 2020; 22:51-66. [PMID: 33188506 DOI: 10.1007/s10162-020-00755-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Accepted: 04/21/2020] [Indexed: 11/27/2022] Open
Abstract
Animal models of noise-induced hearing loss (NIHL) show a dramatic mismatch between cochlear characteristic frequency (CF, based on place of innervation) and the dominant response frequency in single auditory-nerve-fiber responses to broadband sounds (i.e., distorted tonotopy, DT). This noise trauma effect is associated with decreased frequency-tuning-curve (FTC) tip-to-tail ratio, which results from decreased tip sensitivity and enhanced tail sensitivity. Notably, DT is more severe for noise trauma than for metabolic (e.g., age-related) losses of comparable degree, suggesting that individual differences in DT may contribute to speech intelligibility differences in patients with similar audiograms. Although DT has implications for many neural-coding theories for real-world sounds, it has primarily been explored in single-neuron studies that are not viable with humans. Thus, there are no noninvasive measures to detect DT. Here, frequency following responses (FFRs) to a conversational speech sentence were recorded in anesthetized male chinchillas with either normal hearing or NIHL. Tonotopic sources of FFR envelope and temporal fine structure (TFS) were evaluated in normal-hearing chinchillas. Results suggest that FFR envelope primarily reflects activity from high-frequency neurons, whereas FFR-TFS receives broad tonotopic contributions. Representation of low- and high-frequency speech power in FFRs was also assessed. FFRs in hearing-impaired animals were dominated by low-frequency stimulus power, consistent with oversensitivity of high-frequency neurons to low-frequency power. These results suggest that DT can be diagnosed noninvasively. A normalized DT metric computed from speech FFRs provides a potential diagnostic tool to test for DT in humans. A sensitive noninvasive DT metric could be used to evaluate perceptual consequences of DT and to optimize hearing-aid amplification strategies to improve tonotopic coding for hearing-impaired listeners.
Collapse
Affiliation(s)
- Satyabrata Parida
- Weldon School of Biomedical Engineering, Purdue University, 206 South Martin Jischke Drive, West Lafayette, IN, 47907, USA
| | - Michael G Heinz
- Weldon School of Biomedical Engineering, Purdue University, 206 South Martin Jischke Drive, West Lafayette, IN, 47907, USA.
- Department of Speech, Language, and Hearing Sciences, Purdue University, 715 Clinic Drive, West Lafayette, IN, 47907, USA.
| |
Collapse
|
5
|
Van Canneyt J, Wouters J, Francart T. From modulated noise to natural speech: The effect of stimulus parameters on the envelope following response. Hear Res 2020; 393:107993. [PMID: 32535277 DOI: 10.1016/j.heares.2020.107993] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 04/28/2020] [Accepted: 05/04/2020] [Indexed: 11/28/2022]
Abstract
Envelope following responses (EFRs) can be evoked by a wide range of auditory stimuli, but for many stimulus parameters the effect on EFR strength is not fully understood. This complicates the comparison of earlier studies and the design of new studies. Furthermore, the most optimal stimulus parameters are unknown. To help resolve this issue, we investigated the effects of four important stimulus parameters and their interactions on the EFR. Responses were measured in 16 normal hearing subjects evoked by stimuli with four levels of stimulus complexity (amplitude modulated noise, artificial vowels, natural vowels and vowel-consonant-vowel combinations), three fundamental frequencies (105 Hz, 185 Hz and 245 Hz), three fundamental frequency contours (upward sweeping, downward sweeping and flat) and three vowel identities (Flemish /a:/, /u:/, and /i:/). We found that EFRs evoked by artificial vowels were on average 4-6 dB SNR larger than responses evoked by the other stimulus complexities, probably because of (unnaturally) strong higher harmonics. Moreover, response amplitude decreased with fundamental frequency but response SNR remained largely unaffected. Thirdly, fundamental frequency variation within the stimulus did not impact EFR strength, but only when rate of change remained low (e.g. not the case for sweeping natural vowels). Finally, the vowel /i:/ appeared to evoke larger response amplitudes compared to /a:/ and /u:/, but analysis power was too small to confirm this statistically. Vowel-dependent differences in response strength have been suggested to stem from destructive interference between response components. We show how a model of the auditory periphery can simulate these interference patterns and predict response strength. Altogether, the results of this study can guide stimulus choice for future EFR research and practical applications.
Collapse
Affiliation(s)
- Jana Van Canneyt
- ExpORL, Dept. of Neurosciences, KU Leuven, Herestraat 49 Bus 721, 3000, Leuven, Belgium.
| | - Jan Wouters
- ExpORL, Dept. of Neurosciences, KU Leuven, Herestraat 49 Bus 721, 3000, Leuven, Belgium.
| | - Tom Francart
- ExpORL, Dept. of Neurosciences, KU Leuven, Herestraat 49 Bus 721, 3000, Leuven, Belgium.
| |
Collapse
|
6
|
Parthasarathy A, Hancock KE, Bennett K, DeGruttola V, Polley DB. Bottom-up and top-down neural signatures of disordered multi-talker speech perception in adults with normal hearing. eLife 2020; 9:e51419. [PMID: 31961322 PMCID: PMC6974362 DOI: 10.7554/elife.51419] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 12/15/2019] [Indexed: 12/16/2022] Open
Abstract
In social settings, speech waveforms from nearby speakers mix together in our ear canals. Normally, the brain unmixes the attended speech stream from the chorus of background speakers using a combination of fast temporal processing and cognitive active listening mechanisms. Of >100,000 patient records,~10% of adults visited our clinic because of reduced hearing, only to learn that their hearing was clinically normal and should not cause communication difficulties. We found that multi-talker speech intelligibility thresholds varied widely in normal hearing adults, but could be predicted from neural phase-locking to frequency modulation (FM) cues measured with ear canal EEG recordings. Combining neural temporal fine structure processing, pupil-indexed listening effort, and behavioral FM thresholds accounted for 78% of the variability in multi-talker speech intelligibility. The disordered bottom-up and top-down markers of poor multi-talker speech perception identified here could inform the design of next-generation clinical tests for hidden hearing disorders.
Collapse
Affiliation(s)
- Aravindakshan Parthasarathy
- Eaton-Peabody LaboratoriesMassachusetts Eye and Ear InfirmaryBostonUnited States
- Department of Otolaryngology – Head and Neck SurgeryHarvard Medical SchoolBostonUnited States
| | - Kenneth E Hancock
- Eaton-Peabody LaboratoriesMassachusetts Eye and Ear InfirmaryBostonUnited States
- Department of Otolaryngology – Head and Neck SurgeryHarvard Medical SchoolBostonUnited States
| | - Kara Bennett
- Bennett Statistical Consulting IncBallstonUnited States
| | - Victor DeGruttola
- Department of BiostatisticsHarvard TH Chan School of Public HealthBostonUnited States
| | - Daniel B Polley
- Eaton-Peabody LaboratoriesMassachusetts Eye and Ear InfirmaryBostonUnited States
- Department of Otolaryngology – Head and Neck SurgeryHarvard Medical SchoolBostonUnited States
| |
Collapse
|
7
|
Takeuti AA, Fávero ML, Zaia EH, Ganança FF. Auditory brainstem function in women with vestibular migraine: a controlled study. BMC Neurol 2019; 19:144. [PMID: 31248379 PMCID: PMC6595618 DOI: 10.1186/s12883-019-1368-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Accepted: 06/17/2019] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Vestibular migraine (VM) has been recognized as a diagnostic entity over the past three decades. It affects up to 1% of the general population and 7% of patients seen in dizziness clinics. It is still underdiagnosed; consequently, it is important to conduct clinical studies that address diagnostic indicators of VM. The aim of this study was to assess auditory brainstem function in women with vestibular migraine using electrophysiological testing, contralateral acoustic reflex and loudness discomfort level. METHODS The study group consisted of 29 women with vestibular migraine in the interictal period, and the control group comprised 25 healthy women. Auditory brainstem response, frequency following response, binaural interaction component and assessment of contralateral efferent suppression were performed. The threshold of loudness discomfort and the contralateral acoustic reflex were also investigated. The results were compared between the groups. RESULTS There was a statistically significant difference between the groups in the frequency following response and the loudness discomfort level. CONCLUSIONS The current study suggested that temporal auditory processing and loudness discomfort levels are altered in VM patients during the interictal period, indicating that these measures may be useful as diagnostic criteria.
Collapse
Affiliation(s)
- Alice A Takeuti
- Departamento de Otorrinolaringologia e Cirurgia de Cabeça e Pescoço, Universidade Federal de São Paulo, São Paulo, Brazil.
| | - Mariana L Fávero
- Divisão de Educação e Reabilitação dos Distúrbios da Comunicação (DERDIC), Pontíficia Universidade Catolica de São Paulo, São Paulo, Brazil
| | | | - Fernando F Ganança
- Departamento de Otorrinolaringologia e Cirurgia de Cabeça e Pescoço, Universidade Federal de São Paulo, São Paulo, Brazil
| |
Collapse
|
8
|
Wang L, Bharadwaj H, Shinn-Cunningham B. Assessing Cochlear-Place Specific Temporal Coding Using Multi-Band Complex Tones to Measure Envelope-Following Responses. Neuroscience 2019; 407:67-74. [PMID: 30826519 DOI: 10.1016/j.neuroscience.2019.02.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Revised: 02/04/2019] [Accepted: 02/06/2019] [Indexed: 11/16/2022]
Abstract
Previous studies suggest that envelope-following responses (EFRs) reveal important differences in temporal coding fidelity amongst listeners who have normal hearing thresholds, consistent with these listeners differing in the degree to which they suffer from cochlear synaptopathy. Like conventional hearing loss, the severity of cochlear synaptopathy may vary along the cochlea. A number of earlier studies have suggested methods for estimating EFRs driven by specific frequency regions of the cochlea, which would allow synaptopathy to be estimated as a function of cochlear place. Here, we tested a method for measuring EFRs from multiple locations along the cochlea simultaneously, using narrowband stimuli. We compared responses to multiple simultaneous narrowband complex harmonic tones in three non-overlapping frequency bands, each having a unique fundamental frequency, to responses to the individual narrowband stimuli alone, and to responses when noise was added to different combinations of the frequency bands. Our results suggest that simultaneous presentation of multiple tone complexes with different fundamental frequencies leads to repeatable measures of temporal coding fidelity at the cochlear frequency regions corresponding to the narrowband carrier frequencies. Other results suggested that while off-frequency contributions to EFRs driven by narrowband signals (due to spread of excitation) can add destructively to the on frequency response, these interactions were small compared to EFR magnitude. Overall, our results point to the utility of using multi-band complex tone stimuli to estimate the profile of temporal coding fidelity, and thus the degree of synaptopathy, as a function of cochlear place. This article is part of a Special Issue entitled: Hearing Loss, Tinnitus, Hyperacusis, Central Gain.
Collapse
Affiliation(s)
- Le Wang
- Biomedical Engineering, Boston University, 610 Commonwealth Ave, Boston, MA 02215, USA.
| | - Hari Bharadwaj
- Speech, Language, and Hearing Sciences, Purdue University, Lyles-Porter Hall, 715 Clinic Dr., West Lafayette, IN 47907, USA.
| | - Barbara Shinn-Cunningham
- Biomedical Engineering, Boston University, 610 Commonwealth Ave, Boston, MA 02215, USA; Neuroscience Institute, Carnegie Mellon University, Room 115C, 4400 Fifth Ave., Pittsburgh, PA 15213, USA.
| |
Collapse
|
9
|
Peng F, McKay CM, Mao D, Hou W, Innes-Brown H. Auditory Brainstem Representation of the Voice Pitch Contours in the Resolved and Unresolved Components of Mandarin Tones. Front Neurosci 2018; 12:820. [PMID: 30505262 PMCID: PMC6250765 DOI: 10.3389/fnins.2018.00820] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Accepted: 10/22/2018] [Indexed: 11/24/2022] Open
Abstract
Accurate perception of voice pitch plays a vital role in speech understanding, especially for tonal languages such as Mandarin. Lexical tones are primarily distinguished by the fundamental frequency (F0) contour of the acoustic waveform. It has been shown that the auditory system could extract the F0 from the resolved and unresolved harmonics, and the tone identification performance of resolved harmonics was better than unresolved harmonics. To evaluate the neural response to the resolved and unresolved components of Mandarin tones in quiet and in speech-shaped noise, we recorded the frequency-following response. In this study, four types of stimuli were used: speech with either only-resolved harmonics or only-unresolved harmonics, both in quiet and in speech-shaped noise. Frequency-following responses (FFRs) were recorded to alternating-polarity stimuli and were added or subtracted to enhance the neural response to the envelope (FFRENV) or fine structure (FFRTFS), respectively. The neural representation of the F0 strength reflected by the FFRENV was evaluated by the peak autocorrelation value in the temporal domain and the peak phase-locking value (PLV) at F0 in the spectral domain. Both evaluation methods showed that the FFRENV F0 strength in quiet was significantly stronger than in noise for speech including unresolved harmonics, but not for speech including resolved harmonics. The neural representation of the temporal fine structure reflected by the FFRTFS was assessed by the PLV at the harmonic near to F1 (4th of F0). The PLV at harmonic near to F1 (4th of F0) of FFRTFS to resolved harmonics was significantly larger than to unresolved harmonics. Spearman's correlation showed that the FFRENV F0 strength to unresolved harmonics was correlated with tone identification performance in noise (0 dB SNR). These results showed that the FFRENV F0 strength to speech sounds with resolved harmonics was not affected by noise. In contrast, the response to speech sounds with unresolved harmonics, which were significantly smaller in noise compared to quiet. Our results suggest that coding resolved harmonics was more important than coding envelope for tone identification performance in noise.
Collapse
Affiliation(s)
- Fei Peng
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Chongqing, China.,The Bionics Institute of Australia, East Melbourne, VIC, Australia.,Medical Bionics Department, University of Melbourne, Melbourne, VIC, Australia.,Collaborative Innovation Center for Brain Science, Chongqing University, Chongqing, China
| | - Colette M McKay
- The Bionics Institute of Australia, East Melbourne, VIC, Australia.,Medical Bionics Department, University of Melbourne, Melbourne, VIC, Australia
| | - Darren Mao
- The Bionics Institute of Australia, East Melbourne, VIC, Australia.,Department of Biomedical Engineering, University of Melbourne, Melbourne, VIC, Australia
| | - Wensheng Hou
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Chongqing, China.,Collaborative Innovation Center for Brain Science, Chongqing University, Chongqing, China.,Chongqing Engineering Research Center of Medical Electronics Technology, Chongqing University, Chongqing, China
| | - Hamish Innes-Brown
- The Bionics Institute of Australia, East Melbourne, VIC, Australia.,Medical Bionics Department, University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|