Takanen M, Strahl S, Schwarz K. Insights Into Electrophysiological Metrics of Cochlear Health in Cochlear Implant Users Using a Computational Model. J Assoc Res Otolaryngol 2024; 25:63-78. [PMID: 38278970 PMCID: PMC10907331 DOI: 10.1007/s10162-023-00924-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 12/18/2023] [Indexed: 01/28/2024] Open
Abstract
PURPOSE The hearing outcomes of cochlear implant users depend on the functional status of the electrode-neuron interface inside the cochlea. This can be assessed by measuring electrically evoked compound action potentials (eCAPs). Variations in cochlear neural health and survival are reflected in eCAP-based metrics. The difficulty in translating promising results from animal studies into clinical use has raised questions about to what degree eCAP-based metrics are influenced by non-neural factors. Here, we addressed these questions using a computational model. METHODS A 2-D computational model was designed to simulate how electrical signals from the stimulating electrode reach the auditory nerve fibers distributed along the cochlea, evoking action potentials that can be recorded as compound responses at the recording electrodes. Effects of physiologically relevant variations in neural survival and in electrode-neuron and stimulating-recording electrode distances on eCAP amplitude growth functions (AGFs) were investigated. RESULTS In line with existing literature, the predicted eCAP AGF slopes and the inter-phase gap (IPG) effects depended on the neural survival, but only when the IPG effect was calculated as the difference between the slopes of the two AGFs expressed in linear input-output scale. As expected, shallower eCAP AGF slopes were obtained for increased stimulating-recording electrode distance and larger eCAP thresholds for greater electrode-neuron distance. These non-neural factors had also minor interference on the predicted IPG effect. CONCLUSIONS The model predictions demonstrate previously found dependencies of eCAP metrics on neural survival and non-neural aspects. The present findings confirm data from animal studies and provide insights into applying described metrics in clinical practice.
Collapse
Affiliation(s)
- Marko Takanen
- MED-EL Medical Electronics, Research and Development, Fürstenweg 77a, 6020, Innsbruck, Austria.
| | - Stefan Strahl
- MED-EL Medical Electronics, Research and Development, Fürstenweg 77a, 6020, Innsbruck, Austria
| | - Konrad Schwarz
- MED-EL Medical Electronics, Research and Development, Fürstenweg 77a, 6020, Innsbruck, Austria
| |
Collapse
|
2
|
Skidmore J, Yuan Y, He S. A new method for removing artifacts from recordings of the electrically evoked compound action potential: Single-pulse stimulation. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2024:2024.01.17.24301435. [PMID: 38293121 PMCID: PMC10827261 DOI: 10.1101/2024.01.17.24301435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Abstract
This report presents a new method for removing electrical artifact contamination from the electrically evoked compound action potential (eCAP) evoked by single cathodic-leading, biphasic-pulse stimulation. The development of the new method is motivated by results recorded in human cochlear implant (CI) users showing that the fundamental assumption of the classic forward masking artifact rejection technique is violated in up to 45% of cases tested at high stimulation levels when using default stimulation parameters. Subsequently, the new method developed based on the discovery that a hyperbola best characterizes the artifacts created during stimulation and recording is described. The eCAP waveforms obtained using the new method are compared to those recorded using the classic forward masking technique. The results show that eCAP waveforms obtained using both methods are comparable when the fundamental assumption of the classic forward masking technique is met. In contrast, eCAP amplitudes obtained using the two methods are significantly different when the fundamental assumption of the classic forward masking technique is violated, with greater differences in the eCAP amplitude for greater assumption violations. The new method also has excellent test-retest reliability (Intraclass correlation > 0.98). Overall, the new method is a viable alternative to the classic forward masking technique for obtaining artifact-free eCAPs evoked by single-pulse stimulation in CI users.
Collapse
Affiliation(s)
- Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212, USA
| | - Yi Yuan
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212, USA
| | - Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212, USA
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205, USA
| |
Collapse
|
3
|
Liebscher T, Hornung J, Hoppe U. Electrically evoked compound action potentials in cochlear implant users with preoperative residual hearing. Front Hum Neurosci 2023; 17:1125747. [PMID: 37850038 PMCID: PMC10577430 DOI: 10.3389/fnhum.2023.1125747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 09/08/2023] [Indexed: 10/19/2023] Open
Abstract
Introduction Residual hearing in cochlear implant (CI) candidates requires the functional integrity of the nerve in particular regions of the cochlea. Nerve activity can be elicited as electrically evoked compound action potentials (ECAP) after cochlear implantation. We hypothesize that ECAP thresholds depend on preoperative residual hearing ability. Materials and methods In a retrospective study, we analyzed 84 adult cochlear implant users who had received a Nucleus® CI632 Slim Modiolar Electrode and who preoperatively had had residual hearing. Inclusion criteria were severe to profound hearing loss with preoperative measurable hearing in the ear to receive the implant, postlingual hearing loss, German as native language and correct placement of the electrode, inserted completely into the scala tympani. Electrically evoked compound action potential (ECAP) was recorded intraoperatively. The angular insertion was measured for each electrode contact from postoperative computed tomography to estimate the corresponding spiral ganglion frequency. Pure-tone audiometry and allocated ECAP thresholds were tested to investigate possible correlation. Results The average of hearing thresholds, tested at 0.5, 1, 2, and 4 kHz (4FPTA) was 82 ± 18 (range 47-129) dB HL. The success rate for recording ECAP thresholds was 96.9%. For all comparable pure-tone frequencies (1, 2, 4, and 8 kHz), there was significant correlation between preoperative hearing levels and intraoperative ECAP thresholds (p < 0.001). Higher hearing thresholds are associated with increased ECAP thresholds. Conclusion In CI candidates with adequate residual hearing, intraoperative electrophysiological measurement records lower thresholds. This outcome may be explained by the neural survival density of the peripheral system, with less neural degeneration.
Collapse
Affiliation(s)
- Tim Liebscher
- ENT-Clinic, Department of Audiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | | | | |
Collapse
|
4
|
Hughes ML. Electrically evoked compound action potential polarity sensitivity, refractory-recovery, and behavioral multi-pulse integration as potential indices of neural health in cochlear-implant recipients. Hear Res 2023; 433:108764. [PMID: 37062161 PMCID: PMC10322179 DOI: 10.1016/j.heares.2023.108764] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 03/26/2023] [Accepted: 04/05/2023] [Indexed: 04/18/2023]
Affiliation(s)
- Michelle L Hughes
- University of Nebraska-Lincoln, Dept. of Special Education and Communication Disorders, 276 Barkley Memorial Center, 4072 East Campus Loop, Lincoln, NE, 68583, USA.
| |
Collapse
|
5
|
Schvartz-Leyzac KC, Colesa DJ, Swiderski DL, Raphael Y, Pfingst BE. Cochlear Health and Cochlear-implant Function. J Assoc Res Otolaryngol 2023; 24:5-29. [PMID: 36600147 PMCID: PMC9971430 DOI: 10.1007/s10162-022-00882-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 11/24/2022] [Indexed: 01/06/2023] Open
Abstract
The cochlear implant (CI) is widely considered to be one of the most innovative and successful neuroprosthetic treatments developed to date. Although outcomes vary, CIs are able to effectively improve hearing in nearly all recipients and can substantially improve speech understanding and quality of life for patients with significant hearing loss. A wealth of research has focused on underlying factors that contribute to success with a CI, and recent evidence suggests that the overall health of the cochlea could potentially play a larger role than previously recognized. This article defines and reviews attributes of cochlear health and describes procedures to evaluate cochlear health in humans and animal models in order to examine the effects of cochlear health on performance with a CI. Lastly, we describe how future biologic approaches can be used to preserve and/or enhance cochlear health in order to maximize performance for individual CI recipients.
Collapse
Affiliation(s)
- Kara C Schvartz-Leyzac
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, 135 Rutledge Ave, Charleston, SC, 29425, USA
| | - Deborah J Colesa
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Donald L Swiderski
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Yehoash Raphael
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Bryan E Pfingst
- Department of Otolaryngology-Head and Neck Surgery, Michigan Medicine, Kresge Hearing Research Institute, University of Michigan, 1150 Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
| |
Collapse
|
6
|
Guevara N, Truy E, Hoen M, Hermann R, Vandersteen C, Gallego S. Electrical Field Interactions during Adjacent Electrode Stimulations: eABR Evaluation in Cochlear Implant Users. J Clin Med 2023; 12:jcm12020605. [PMID: 36675534 PMCID: PMC9865217 DOI: 10.3390/jcm12020605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/06/2023] [Accepted: 01/10/2023] [Indexed: 01/15/2023] Open
Abstract
The present study investigates how electrically evoked Auditory Brainstem Responses (eABRs) can be used to measure local channel interactions along cochlear implant (CI) electrode arrays. eABRs were recorded from 16 experienced CI patients in response to electrical pulse trains delivered using three stimulation configurations: (1) single electrode stimulations (E11 or E13); (2) simultaneous stimulation from two electrodes separated by one (En and En+2, E11 and E13); and (3) stimulations from three consecutive electrodes (E11, E12, and E13). Stimulation level was kept constant at 70% electrical dynamic range (EDR) on the two flanking electrodes (E11 and E13) and was varied from 0 to 100% EDR on the middle electrode (E12). We hypothesized that increasing the middle electrode stimulation level would cause increasing local electrical interactions, reflected in characteristics of the evoked compound eABR. Results show that group averaged eABR wave III and V latency and amplitude were reduced when stimulation level at the middle electrode was increased, in particular when stimulation level on E12 reached 40, 70, and 100% EDR. Compound eABRs can provide a detailed individual quantification of electrical interactions occurring at specific electrodes along the CI electrode array. This approach allows a fine determination of interactions at the single electrode level potentially informing audiological decisions regarding mapping of CI systems.
Collapse
Affiliation(s)
- Nicolas Guevara
- Institut Universitaire de la Face et du Cou, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| | - Eric Truy
- Department of Audiology and Otorhinolaryngology, Edouard Herriot Hospital, Lyon 1 University, 69437 Lyon, France
| | - Michel Hoen
- Clinical Evidence Department, Oticon Medical, 06220 Vallauris, France
- Correspondence:
| | - Ruben Hermann
- Department of Audiology and Otorhinolaryngology, Edouard Herriot Hospital, Lyon 1 University, 69437 Lyon, France
| | - Clair Vandersteen
- Institut Universitaire de la Face et du Cou, Centre Hospitalier Universitaire de Nice, Université Côte d’Azur, 06100 Nice, France
| | - Stéphane Gallego
- Institute for Readaptation Sciences and Techniques, Lyon 1 University, 69373 Lyon, France
| |
Collapse
|
7
|
Changes in the Electrically Evoked Compound Action Potential over time After Implantation and Subsequent Deafening in Guinea Pigs. J Assoc Res Otolaryngol 2022; 23:721-738. [PMID: 35948695 PMCID: PMC9789241 DOI: 10.1007/s10162-022-00864-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 07/12/2022] [Indexed: 01/06/2023] Open
Abstract
The electrically evoked compound action potential (eCAP) is a direct measure of the responsiveness of the auditory nerve to electrical stimulation from a cochlear implant (CI). CIs offer a unique opportunity to study the auditory nerve's electrophysiological behavior in individual human subjects over time. In order to understand exactly how the eCAP relates to the condition of the auditory nerve, it is crucial to compare changes in the eCAP over time in a controlled model of deafness-induced auditory nerve degeneration. In the present study, 10 normal-hearing young adult guinea pigs were implanted and deafened 4 weeks later, so that the effect of deafening could be monitored within-subject over time. Following implantation, but before deafening, most examined eCAP characteristics significantly changed, suggesting increasing excitation efficacy (e.g., higher maximum amplitude, lower threshold, shorter latency). Conversely, inter-phase gap (IPG) effects on these measures - within-subject difference measures that have been shown to correlate well with auditory nerve survival - did not vary for most eCAP characteristics. After deafening, we observed an initial increase in excitability (steeper slope of the eCAP amplitude growth function (AGF), lower threshold, shorter latency and peak width) which typically returned to normal-hearing levels within a week, after which a slower process, probably reflecting spiral ganglion cell loss, took place over the remaining 6 weeks (e.g., decrease in maximum amplitude, AGF slope, peak area, and IPG effect for AGF slope; increase in IPG effect for latency). Our results suggest that gradual changes in peak width and latency reflect the rate of neural degeneration, while peak area, maximum amplitude, and AGF slope reflect neural population size, which may be valuable for clinical diagnostics.
Collapse
|
8
|
Arslan NO, Luo X. Assessing the Relationship Between Pitch Perception and Neural Health in Cochlear Implant Users. J Assoc Res Otolaryngol 2022; 23:875-887. [PMID: 36329369 PMCID: PMC9789247 DOI: 10.1007/s10162-022-00876-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022] Open
Abstract
Various neural health estimates have been shown to indicate the density of spiral ganglion neurons in animal and modeling studies of cochlear implants (CIs). However, when applied to human CI users, these neural health estimates based on psychophysical and electrophysiological measures are not consistently correlated with each other or with the speech recognition performance. This study investigated whether the neural health estimates have stronger correlations with the temporal and place pitch sensitivity than with the speech recognition performance. On five electrodes in 12 tested ears of eight adult CI users, polarity effect (PE), multipulse integration (MPI), and interphase gap (IPG) effect on the amplitude growth function (AGF) of electrically evoked compound action potential (ECAP) were measured to estimate neural health, while thresholds of amplitude modulation frequency ranking (AMFR) and virtual channel ranking (VCR) were measured to indicate temporal and place pitch sensitivity. AzBio sentence recognition in noise was measured using the clinical CI processor for each ear. The results showed significantly poorer AMFR and VCR thresholds on the basal electrodes than on the apical and middle electrodes. Across ears and electrodes, only the IPG offset effect on ECAP AGF had a nearly significant negative correlation with the VCR threshold after removing the outliers. No significant across-ear correlations were found between the mean neural health estimates, mean pitch-ranking thresholds, and AzBio sentence recognition score. This study suggests that the central axon demyelination reflected by the IPG offset effect may be important for the place pitch sensitivity of CI users and that the IPG offset effect may be used to predict the perceptual resolution of virtual channels for CI programming.
Collapse
Affiliation(s)
- Niyazi O. Arslan
- Program of Speech and Hearing Science, College of Health Solutions, Arizona State University, 975 S. Myrtle Av., Tempe, AZ 85287 USA
| | - Xin Luo
- Program of Speech and Hearing Science, College of Health Solutions, Arizona State University, 975 S. Myrtle Av., Tempe, AZ 85287 USA
| |
Collapse
|
9
|
Comparison of response properties of the electrically stimulated auditory nerve reported in human listeners and in animal models. Hear Res 2022; 426:108643. [PMID: 36343534 PMCID: PMC9986845 DOI: 10.1016/j.heares.2022.108643] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 09/29/2022] [Accepted: 10/20/2022] [Indexed: 11/04/2022]
Abstract
Cochlear implants (CIs) provide acoustic information to implanted patients by electrically stimulating nearby auditory nerve fibers (ANFs) which then transmit the information to higher-level neural structures for further processing and interpretation. Computational models that simulate ANF responses to CI stimuli enable the exploration of the mechanisms underlying CI performance beyond the capacity of in vivo experimentation alone. However, all ANF models developed to date utilize to some extent anatomical/morphometric data, biophysical properties and/or physiological data measured in non-human animal models. This review compares response properties of the electrically stimulated auditory nerve (AN) in human listeners and different mammalian models. Properties of AN responses to single pulse stimulation, paired-pulse stimulation, and pulse-train stimulation are presented. While some AN response properties are similar between human listeners and animal models (e.g., increased AN sensitivity to single pulse stimuli with long interphase gaps), there are some significant differences. For example, the AN of most animal models is typically more sensitive to cathodic stimulation while the AN of human listeners is generally more sensitive to anodic stimulation. Additionally, there are substantial differences in the speed of recovery from neural adaptation between animal models and human listeners. Therefore, results from animal models cannot be simply translated to human listeners. Recognizing the differences in responses of the AN to electrical stimulation between humans and other mammals is an important step for creating ANF models that are more applicable to various human CI patient populations.
Collapse
|
10
|
Hughes ML. Characterizing Polarity Sensitivity in Cochlear Implant Recipients: Demographic Effects and Potential Implications for Estimating Neural Health. J Assoc Res Otolaryngol 2022; 23:301-318. [PMID: 34988867 DOI: 10.1007/s10162-021-00824-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 11/17/2021] [Indexed: 11/29/2022] Open
Abstract
Stimulus polarity can affect both physiological and perceptual measures in cochlear-implant recipients. Large differences between polarities for various outcome measures (e.g., eCAP threshold, amplitude, or slope) theoretically reflect poorer neural health, whereas smaller differences reflect better neural health. Therefore, we expect large polarity effects to be correlated with other measures shown to contribute to poor neural health, such as advanced age or prolonged deafness. Our earlier studies using the electrically evoked compound action potential (eCAP) demonstrated differences in polarity effects between users of Cochlear and Advanced Bionics devices when device-specific clinical pulse designs were used. Since the stimuli differed slightly between devices, the first goal of this study was to determine whether small, clinically relevant differences in pulse phase duration (PD) have a significant impact on eCAP polarity effects to potentially explain the device differences observed previously. Polarity effects were quantified as the difference in eCAP thresholds, mean normalized amplitudes, and slope of the amplitude growth function obtained for anodic-first versus cathodic-first biphasic pulses. The results showed that small variations in PD did not explain the observed differences in eCAP polarity effects between devices. Therefore, eCAP polarity sensitivity measures are relatively robust to small differences in pulse parameters. However, it remains unclear what underlies the observed manufacturer differences, which may limit the utility of eCAP polarity sensitivity measures. The second goal was to characterize polarity sensitivity in a large group of CI recipients (65 ears) to relate polarity sensitivity to age and duration of deafness as a proxy for neural health. The same pulse parameters were used for both device groups. The only significant predictors of eCAP polarity effects were age for threshold and amplitude polarity effects for Cochlear recipients and age and duration of deafness for slope for AB recipients. However, three of these four correlations were in the opposite direction of what was expected. These results suggest that eCAP polarity sensitivity measures likely reflect different mechanisms than the effects that age and duration of deafness induce on the peripheral auditory system.
Collapse
Affiliation(s)
- Michelle L Hughes
- Department of Special Education and Communication Disorders, University of Nebraska-Lincoln, 276 Barkley Memorial Center, Lincoln, NE, 68583, USA.
| |
Collapse
|
11
|
Assessing the relationship between neural health measures and speech performance with simultaneous electric stimulation in cochlear implant listeners. PLoS One 2021; 16:e0261295. [PMID: 34898654 PMCID: PMC8668108 DOI: 10.1371/journal.pone.0261295] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 11/29/2021] [Indexed: 11/19/2022] Open
Abstract
Objectives The relationship between electrode-nerve interface (ENI) estimates and inter-subject differences in speech performance with sequential and simultaneous channel stimulation in adult cochlear implant listeners were explored. We investigated the hypothesis that individuals with good ENIs would perform better with simultaneous compared to sequential channel stimulation speech processing strategies than those estimated to have poor ENIs. Methods Fourteen postlingually deaf implanted cochlear implant users participated in the study. Speech understanding was assessed with a sentence test at signal-to-noise ratios that resulted in 50% performance for each user with the baseline strategy F120 Sequential. Two simultaneous stimulation strategies with either two (Paired) or three sets of virtual channels (Triplet) were tested at the same signal-to-noise ratio. ENI measures were estimated through: (I) voltage spread with electrical field imaging, (II) behavioral detection thresholds with focused stimulation, and (III) slope (IPG slope effect) and 50%-point differences (dB offset effect) of amplitude growth functions from electrically evoked compound action potentials with two interphase gaps. Results A significant effect of strategy on speech understanding performance was found, with Triplets showing a trend towards worse speech understanding performance than sequential stimulation. Focused thresholds correlated positively with the difference required to reach most comfortable level (MCL) between Sequential and Triplet strategies, an indirect measure of channel interaction. A significant offset effect (difference in dB between 50%-point for higher eCAP growth function slopes with two IPGs) was observed. No significant correlation was observed between the slopes for the two IPGs tested. None of the measures used in this study correlated with the differences in speech understanding scores between strategies. Conclusions The ENI measure based on behavioral focused thresholds could explain some of the difference in MCLs, but none of the ENI measures could explain the decrease in speech understanding with increasing pairs of simultaneously stimulated electrodes in processing strategies.
Collapse
|
12
|
Carlyon RP, Goehring T. Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update. J Assoc Res Otolaryngol 2021; 22:481-508. [PMID: 34432222 PMCID: PMC8476711 DOI: 10.1007/s10162-021-00811-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 08/02/2021] [Indexed: 12/22/2022] Open
Abstract
Cochlear implants (CIs) are the world's most successful sensory prosthesis and have been the subject of intense research and development in recent decades. We critically review the progress in CI research, and its success in improving patient outcomes, from the turn of the century to the present day. The review focuses on the processing, stimulation, and audiological methods that have been used to try to improve speech perception by human CI listeners, and on fundamental new insights in the response of the auditory system to electrical stimulation. The introduction of directional microphones and of new noise reduction and pre-processing algorithms has produced robust and sometimes substantial improvements. Novel speech-processing algorithms, the use of current-focusing methods, and individualised (patient-by-patient) deactivation of subsets of electrodes have produced more modest improvements. We argue that incremental advances have and will continue to be made, that collectively these may substantially improve patient outcomes, but that the modest size of each individual advance will require greater attention to experimental design and power. We also briefly discuss the potential and limitations of promising technologies that are currently being developed in animal models, and suggest strategies for researchers to collectively maximise the potential of CIs to improve hearing in a wide range of listening situations.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK.
| | - Tobias Goehring
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK
| |
Collapse
|
13
|
Imsiecke M, Büchner A, Lenarz T, Nogueira W. Amplitude Growth Functions of Auditory Nerve Responses to Electric Pulse Stimulation With Varied Interphase Gaps in Cochlear Implant Users With Ipsilateral Residual Hearing. Trends Hear 2021; 25:23312165211014137. [PMID: 34181493 PMCID: PMC8243142 DOI: 10.1177/23312165211014137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Amplitude growth functions (AGFs) of electrically evoked compound action
potentials (eCAPs) with varying interphase gaps (IPGs) were measured in cochlear
implant users with ipsilateral residual hearing (electric-acoustic stimulation
[EAS]). It was hypothesized that IPG effects on AGFs provide an objective
measure to estimate neural health. This hypothesis was tested in EAS users, as
residual low-frequency hearing might imply survival of hair cells and hence
better neural health in apical compared to basal cochlear regions. A total of 16
MED-EL EAS subjects participated, as well as a control group of 16 deaf cochlear
implant users. The IPG effect on the AGF characteristics of slope, threshold,
dynamic range, and stimulus level at 50% maximum eCAP amplitude
(level50%) was investigated. AGF threshold and
level50% were significantly affected by the IPG in both EAS and
control group. The magnitude of AGF characteristics correlated with electrode
impedance and electrode-modiolus distance (EMD) in both groups. In contrast, the
change of the AGF characteristics with increasing IPG was independent of these
electrode-specific measures. The IPG effect on the AGF level50% in
both groups, as well as on the threshold in EAS users, correlated with the
duration of hearing loss, which is a predictor of neural health. In EAS users, a
significantly different IPG effect on level50% was found between
apical and medial electrodes. This outcome is consistent with our hypothesis
that the influence of IPG effects on AGF characteristics provides a sensitive
measurement and may indicate better neural health in the apex compared to the
medial cochlear region in EAS users.
Collapse
Affiliation(s)
- Marina Imsiecke
- Clinic for Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - Andreas Büchner
- Clinic for Otorhinolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing4All," Hannover, Germany
| | - Thomas Lenarz
- Clinic for Otorhinolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing4All," Hannover, Germany
| | - Waldo Nogueira
- Clinic for Otorhinolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence "Hearing4All," Hannover, Germany
| |
Collapse
|
14
|
The effect of increased channel interaction on speech perception with cochlear implants. Sci Rep 2021; 11:10383. [PMID: 34001987 PMCID: PMC8128897 DOI: 10.1038/s41598-021-89932-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Accepted: 04/29/2021] [Indexed: 11/30/2022] Open
Abstract
Cochlear implants (CIs) are neuroprostheses that partially restore hearing for people with severe-to-profound hearing loss. While CIs can provide good speech perception in quiet listening situations for many, they fail to do so in environments with interfering sounds for most listeners. Previous research suggests that this is due to detrimental interaction effects between CI electrode channels, limiting their function to convey frequency-specific information, but evidence is still scarce. In this study, an experimental manipulation called spectral blurring was used to increase channel interaction in CI listeners using Advanced Bionics devices with HiFocus 1J and MS electrode arrays to directly investigate its causal effect on speech perception. Instead of using a single electrode per channel as in standard CI processing, spectral blurring used up to 6 electrodes per channel simultaneously to increase the overlap between adjacent frequency channels as would occur in cases with severe channel interaction. Results demonstrated that this manipulation significantly degraded CI speech perception in quiet by 15% and speech reception thresholds in babble noise by 5 dB when all channels were blurred by a factor of 6. Importantly, when channel interaction was increased just on a subset of electrodes, speech scores were mostly unaffected and were only significantly degraded when the 5 most apical channels were blurred. These apical channels convey information up to 1 kHz at the apical end of the electrode array and are typically located at angular insertion depths of about 250 up to 500°. These results confirm and extend earlier findings indicating that CI speech perception may not benefit from deactivating individual channels along the array and that efforts should instead be directed towards reducing channel interaction per se and in particular for the most-apical electrodes. Hereby, causal methods such as spectral blurring could be used in future research to control channel interaction effects within listeners for evaluating compensation strategies.
Collapse
|
15
|
The Panoramic ECAP Method: Estimating Patient-Specific Patterns of Current Spread and Neural Health in Cochlear Implant Users. J Assoc Res Otolaryngol 2021; 22:567-589. [PMID: 33891218 PMCID: PMC8476702 DOI: 10.1007/s10162-021-00795-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 03/04/2021] [Indexed: 11/24/2022] Open
Abstract
The knowledge of patient-specific neural excitation patterns from cochlear implants (CIs) can provide important information for optimizing efficacy and improving speech perception outcomes. The Panoramic ECAP (‘PECAP’) method (Cosentino et al. 2015) uses forward-masked electrically evoked compound action-potentials (ECAPs) to estimate neural activation patterns of CI stimulation. The algorithm requires ECAPs be measured for all combinations of probe and masker electrodes, exploiting the fact that ECAP amplitudes reflect the overlapping excitatory areas of both probes and maskers. Here we present an improved version of the PECAP algorithm that imposes biologically realistic constraints on the solution, that, unlike the previous version, produces detailed estimates of neural activation patterns by modelling current spread and neural health along the intracochlear electrode array and is capable of identifying multiple regions of poor neural health. The algorithm was evaluated for reliability and accuracy in three ways: (1) computer-simulated current-spread and neural-health scenarios, (2) comparisons to psychophysical correlates of neural health and electrode-modiolus distances in human CI users, and (3) detection of simulated neural ‘dead’ regions (using forward masking) in human CI users. The PECAP algorithm reliably estimated the computer-simulated scenarios. A moderate but significant negative correlation between focused thresholds and the algorithm’s neural-health estimates was found, consistent with previous literature. It also correctly identified simulated ‘dead’ regions in all seven CI users evaluated. The revised PECAP algorithm provides an estimate of neural excitation patterns in CIs that could be used to inform and optimize CI stimulation strategies for individual patients in clinical settings.
Collapse
|
16
|
Brochier T, McKay CM, Carlyon RP. Interpreting the Effect of Stimulus Parameters on the Electrically Evoked Compound Action Potential and on Neural Health Estimates. J Assoc Res Otolaryngol 2020; 22:81-94. [PMID: 33108575 PMCID: PMC7823000 DOI: 10.1007/s10162-020-00774-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Accepted: 10/14/2020] [Indexed: 02/03/2023] Open
Abstract
Variations in the condition of the neural population along the length of the cochlea can degrade the spectral and temporal representation of sounds conveyed by CIs, thereby limiting speech perception. One measurement that has been proposed as an estimate of neural survival (the number of remaining functional neurons) or neural health (the health of those remaining neurons) is the effect of stimulation parameters, such as the interphase gap (IPG), on the amplitude growth function (AGF) of the electrically evoked compound action potential (ECAP). The extent to which such measures reflect neural factors, rather than non-neural factors (e.g. electrode orientation, electrode-modiolus distance, and impedance), depends crucially upon how the AGF data are analysed. However, there is currently no consensus in the literature for the correct method to interpret changes in the ECAP AGF due to changes in stimulation parameters. We present a simple theoretical model for the effect of IPG on ECAP AGFs, along with a re-analysis of both animal and human data that measured the IPG effect. Both the theoretical model and the re-analysis of the animal data suggest that the IPG effect on ECAP AGF slope (IPG slope effect), measured using either a linear or logarithmic input-output scale, does not successfully control for the effects of non-neural factors. Both the model and the data suggest that the appropriate method to estimate neural health is by measuring the IPG offset effect, defined as the dB offset between the linear portions of ECAP AGFs for two stimuli differing only in IPG.
Collapse
Affiliation(s)
- Tim Brochier
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK.
| | - Colette M McKay
- Bionics Institute, 384-388 Albert Street, East Melbourne, VIC, 3002, Australia
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| |
Collapse
|