1
|
Zhao Y, Hu G, Yan Y, Wang Z, Liu X, Shi H. Biomechanical analysis of ocular diseases and its in vitro study methods. Biomed Eng Online 2022; 21:49. [PMID: 35870978 PMCID: PMC9308301 DOI: 10.1186/s12938-022-01019-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Accepted: 07/13/2022] [Indexed: 12/25/2022] Open
Abstract
Ocular diseases are closely related to the physiological changes in the eye sphere and its contents. Using biomechanical methods to explore the relationship between the structure and function of ocular tissue is beneficial to reveal the pathological processes. Studying the pathogenesis of various ocular diseases will be helpful for the diagnosis and treatment of ocular diseases. We provide a critical review of recent biomechanical analysis of ocular diseases including glaucoma, high myopia, and diabetes. And try to summarize the research about the biomechanical changes in ocular tissues (e.g., optic nerve head, sclera, cornea, etc.) associated with those diseases. The methods of ocular biomechanics research in vitro in recent years are also reviewed, including the measurement of biomechanics by ophthalmic equipment, finite element modeling, and biomechanical analysis methods. And the preparation and application of microfluidic eye chips that emerged in recent years were summarized. It provides new inspiration and opportunity for the pathogenesis of eye diseases and personalized and precise treatment.
Collapse
|
2
|
Correlation study of biomechanical changes between diabetic eye disease and glaucoma using finite element model of human eye with different iris-lens channel distances. Med Eng Phys 2022; 109:103910. [DOI: 10.1016/j.medengphy.2022.103910] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 10/08/2022] [Accepted: 10/16/2022] [Indexed: 11/06/2022]
|
3
|
Foster WJ, Berg BW, Luminais SN, Hadayer A, Schaal S. Computational Modeling of Ophthalmic Procedures: Computational Modeling of Ophthalmic Procedures. Am J Ophthalmol 2022; 241:87-107. [PMID: 35358485 PMCID: PMC9444883 DOI: 10.1016/j.ajo.2022.03.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 01/16/2022] [Accepted: 03/17/2022] [Indexed: 11/01/2022]
Abstract
PURPOSE To explore how finite-element calculations can continue to contribute to diverse problems in ophthalmology and vision science, we describe our recent work on modeling the force on the peripheral retina in intravitreal injections and how that force increases with shorter, smaller gauge needles. We also present a calculation that determines the location and stress on a retinal pigment epithelial detachment during an intravitreal injection, the possibility that stress induced by the injection can lead to a tear of the retinal pigment epithelium. BACKGROUND Advanced computational models can provide a critical insight into the underlying physics in many surgical procedures, which may not be intuitive. METHODS The simulations were implemented using COMSOL Multiphysics. We compared the monkey retinal adhesive force of 18 Pa with the results of this study to quantify the maximum retinal stress that occurs during intravitreal injections. CONCLUSIONS Currently used 30-gauge needles produce stress on the retina during intravitreal injections that is only slightly below the limit that can create retinal tears. As retina specialists attempt to use smaller needles, the risk of complications may increase. In addition, we find that during an intravitreal injection, the stress on the retina in a pigment epithelial detachment occurs at the edge of the detachment (found clinically), and the stress is sufficient to tear the retina. These findings may guide physicians in future clinical research. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.
Collapse
Affiliation(s)
- William J Foster
- From the Department of Bioengineering (W.J.F.), Lewes Katz School of Medicine (B.W.B., S.N.L.), Temple University, Philadelphia, Pennsylvania, USA; Altasciences, Montréal, Québec, Canada (W.J.F.).
| | - Brian W Berg
- From the Department of Bioengineering (W.J.F.), Lewes Katz School of Medicine (B.W.B., S.N.L.), Temple University, Philadelphia, Pennsylvania, USA
| | - Steven N Luminais
- From the Department of Bioengineering (W.J.F.), Lewes Katz School of Medicine (B.W.B., S.N.L.), Temple University, Philadelphia, Pennsylvania, USA
| | - Amir Hadayer
- Department of Ophthalmology, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel (A.H.)
| | - Shlomit Schaal
- Department of Ophthalmology, University of Massachusetts Medical School, Worcester, Massachusetts, USA (S.S.)
| |
Collapse
|
4
|
Yang J, Wu S, Ren Q, Wang J, Gao Z, Li X, Chen W. Adhesion is safe to the refractive surgeries: A theoretical analysis. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2022.100136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
5
|
Li H, Chen M, Zhou Q, Pan X, Cheng J, Cong L, Zhang T, Dong Y, Xie L. Biomechanical Effects of Deep Anterior Lamellar Keratoplasty and Penetrating Keratoplasty for Keratoconus: A Finite Element Analysis. Transl Vis Sci Technol 2021; 10:15. [PMID: 34388236 PMCID: PMC8363774 DOI: 10.1167/tvst.10.9.15] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To theoretically compare corneal displacement and the von Mises (VM) stress distribution of deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) for keratoconus (KC) and to evaluate the effects of residual stromal thickness (RST) and intraocular pressure (IOP) on postoperative corneal biomechanics. Methods We performed DALK and PK simulations using Ansys by employing anisotropic nonlinear hyperelastic corneal material properties. We analyzed corneal displacement and VM stress in DALK and PK models under IOPs of 10, 15, 20, and 25 mmHg. We established two DALK models: The ideal-type DALK ensured that postoperative central corneal thickness was constant at 560 µm and the corneal graft thickness varied with RST. The clinical-type DALK ensured that corneal grafts had the same thickness (500 µm) regardless of RST. Then we analyzed the effects of RST and IOP on postoperative corneal displacement and VM stress. Results Corneal displacement and VM stress were lower in the DALK than in the PK model. In the ideal-type DALK model, an increase in RST was associated with increased deformation and decreased VM stress in the healing zone, except for a RST of 0 µm. In the clinical-type DALK model, deformation and VM stress in the healing zone decreased with an increase in RST, except for a RST of 0 µm. Conclusions DALK showed more stability than PK. For the ideal-type DALK model, an increase in RST resulted in decreased postoperative corneal biomechanics in the healing zone. For the clinical-type DALK model, corneal deformation and VM stress decreased with an increase in RST, which provides numerical evidence for the design of corneal transplantation for patients with KC. Translational Relevance In this computational modeling study, we first theoretically compared corneal biomechanics between DALK and PK for KC. Then, the effects of RST and IOP on postoperative corneal biomechanics were investigated. Our findings provide novel insights into the optimal design for corneal transplantation for patients with KC.
Collapse
Affiliation(s)
- Hua Li
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Min Chen
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Qingdao, China.,Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Qingjun Zhou
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Qingdao, China.,Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Xiaojing Pan
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Qingdao, China.,Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Jun Cheng
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Qingdao, China.,Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Lin Cong
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Qingdao, China.,Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Ting Zhang
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Qingdao, China.,Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Yanling Dong
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Qingdao, China.,Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| | - Lixin Xie
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Qingdao, China.,Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
| |
Collapse
|
6
|
Bagheri NM, Kadkhodaei M, Pirhadi S, Mosaddegh P. Effects of intracorneal ring segments implementation technique and design on corneal biomechanics and keratometry in a personalized computational analysis. Sci Rep 2021; 11:14433. [PMID: 34257343 PMCID: PMC8277910 DOI: 10.1038/s41598-021-93821-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 06/30/2021] [Indexed: 11/08/2022] Open
Abstract
The implementation of intracorneal ring segments (ICRS) is one of the successfully applied refractive operations for the treatment of keratoconus (kc) progression. The different selection of ICRS types along with the surgical implementation techniques can significantly affect surgical outcomes. Thus, this study aimed to investigate the influence of ICRS implementation techniques and design on the postoperative biomechanical state and keratometry results. The clinical data of three patients with different stages and patterns of keratoconus were assessed to develop a three-dimensional (3D) patient-specific finite-element model (FEM) of the keratoconic cornea. For each patient, the exact surgery procedure definitions were interpreted in the step-by-step FEM. Then, seven surgical scenarios, including different ICRS designs (complete and incomplete segment), with two surgical implementation methods (tunnel incision and lamellar pocket cut), were simulated. The pre- and postoperative predicted results of FEM were validated with the corresponding clinical data. For the pre- and postoperative results, the average error of 0.4% and 3.7% for the mean keratometry value ([Formula: see text]) were predicted. Furthermore, the difference in induced flattening effects was negligible for three ICRS types (KeraRing segment with arc-length of 355, 320, and two separate 160) of equal thickness. In contrast, the single and double progressive thickness of KeraRing 160 caused a significantly lower flattening effect compared to the same type with constant thickness. The observations indicated that the greater the segment thickness and arc-length, the lower the induced mean keratometry values. While the application of the tunnel incision method resulted in a lower [Formula: see text] value for moderate and advanced KC, the induced maximum Von Mises stress on the postoperative cornea exceeded the induced maximum stress on the cornea more than two to five times compared to the pocket incision and the preoperative state of the cornea. In particular, an asymmetric regional Von Mises stress on the corneal surface was generated with a progressive ICRS thickness. These findings could be an early biomechanical sign for a later corneal instability and ICRS migration. The developed methodology provided a platform to personalize ICRS refractive surgery with regard to the patient's keratoconus stage in order to facilitate the efficiency and biomechanical stability of the surgery.
Collapse
Affiliation(s)
- Niksa Mohammadi Bagheri
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran
| | - Mahmoud Kadkhodaei
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran
| | - Shiva Pirhadi
- Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, 14778-93855, Iran
| | - Peiman Mosaddegh
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
| |
Collapse
|
7
|
Goles N, Nerancic M, Konjik S, Pajic-Eggspuehler B, Pajic B, Cvejic Z. Phacoemulsification and IOL-Implantation without Using Viscoelastics: Combined Modeling of Thermo Fluid Dynamics, Clinical Outcomes, and Endothelial Cell Density. SENSORS 2021; 21:s21072399. [PMID: 33808502 PMCID: PMC8037460 DOI: 10.3390/s21072399] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 03/13/2021] [Accepted: 03/19/2021] [Indexed: 11/16/2022]
Abstract
Phacoemulsification is a widely used surgical method in cataract surgery with a high energy ultrasound source. The viscoelastic is considered to be tissue protective. The aim of this study is to investigate during surgery the impact of using viscoelastic versus no viscoelastic on clinical outcomes, potential complications and effect on endothelial cell density. The study group included 64 patients, who were subjected to phacoemulsification using balanced salt solution (BSS). Control group consisted of 62 patients, who underwent phacoemulsification using Hyaloronic acid 1% Healon 1%. Student’s t-test was applied for statistical analysis. The simulations of temperature changes during phacoemulsification were performed by COMSOL Multiphysics software. In the BSS group, a mean endothelial cell loss (ECL) of 4.5% was measured one month postoperatively, while in the Healon group ECL was 5.3%. Data analysis showed no significant difference in ECL between the groups (Student’s t-test, p = 0.8). No significant difference was observed in endothelial cell morphology and IOP between the two groups pre- and postoperatively (all p > 0.05). The modeling of thermo fluid dynamics showed that the heating of the cornea is slightly less when Healon was used as irrigation fluid. The phacoemulsification technique can be performed by an experienced surgeon with viscoelastics or continuous anterior chamber (AC) irrigation on the same level of safety regarding endothelial cell damage, providing equally satisfying clinical outcomes.
Collapse
Affiliation(s)
- Nikola Goles
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia; (N.G.); (M.N.); (B.P.)
| | - Marko Nerancic
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia; (N.G.); (M.N.); (B.P.)
| | - Sanja Konjik
- Department of Mathematics and Informatics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia;
| | | | - Bojan Pajic
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia; (N.G.); (M.N.); (B.P.)
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach AG, Switzerland;
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia; (N.G.); (M.N.); (B.P.)
- Correspondence:
| |
Collapse
|