Resan M, Cvejic Z, Pancevski I, Thumann G, Kropp M, Guber I, Ristic D, Vojvodic D, Pajic B. Interleukin 12 in the Acute Phase of the Immune Response after Excimer Laser Treatment. J Clin Med 2023; 12:4472. [PMID: 37445506 DOI: 10.3390/jcm12134472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 06/20/2023] [Accepted: 06/30/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND AND OBJECTIVES The aim of the research was to investigate the differences in the concentrations of IL-12, IL-4, IL-10, and IFN-γ in tears after LASIK and PRK procedures. MATERIALS AND METHODS The study included 68 myopic eyes up to -3.0 D refractive spherical equivalent, divided into two groups: Group 1 LASIK (n = 31) and Group 2 PRK (n = 37). Three tear samples were taken from each eye: immediately before the procedure (t0), 1 h after the procedure (t1), and 24 h after the procedure (t2). The concentrations of IL-12p70, IL-4, IL-10, and IFN-γ in the tear samples were determined by flow cytometry. Participants were not taking anti-inflammatory therapy 24 h after the procedure. RESULTS IL-4 levels 1 h after treatment did not differ between LASIK and PRK (p = 0.990), while 24 h after PRK there was a significant decrease in IL-4 levels (p < 0.05), but not after LASIK (p = 0.476). In both the LASIK (p < 0.05) and PRK (p < 0.05) groups, there is an increase in IL-10 concentrations 1 h after treatment, which persists 24 h after LASIK (p < 0.05) but not after PRK (p = 0.081). There is an increase in IL-12p70 concentration 1 h after treatment in both the LASIK (p < 0.001) and PRK groups (p < 0.001). There is also an increase in IL-12p70 concentration 24 h after PRK (p < 0.005), but not after LASIK (p = 0.775). CONCLUSIONS IL-4 concentration shows a significantly higher value in the LASIK group than in the PRK group after 24 h. IL-10 and IL-12p70 levels increase one hour after surgery in both groups. After 24 h, the IL-10 levels remain elevated in the LASIK group, and the IL-12p70 levels remain elevated in the PRK group. Thus, LASIK and PRK procedures show different inflammatory dynamics.
Collapse
Affiliation(s)
- Mirko Resan
- Eye Clinic, Military Medical Academy, 11000 Belgrade, Serbia
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia
| | - Igor Pancevski
- Eye Clinic, Military Medical Academy, 11000 Belgrade, Serbia
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
| | - Gabriele Thumann
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
| | - Martina Kropp
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
| | - Ivo Guber
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
| | - Dragana Ristic
- Eye Clinic, Military Medical Academy, 11000 Belgrade, Serbia
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
| | - Danilo Vojvodic
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
- Department for Clinical and Experimental Immunology, Institute for Medical Research, Military Medical Academy, 11000 Belgrade, Serbia
| | - Bojan Pajic
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
- Eye Clinic ORASIS, Swiss Eye Research Foundation, 5734 Reinach, Switzerland
| |
Collapse
|
2
|
Sanmillan IL, Thumann G, Kropp M, Cvejic Z, Pajic B. Predictability of Astigmatism Correction by Arcuate Incisions with a Femtosecond Laser Using the Gaussian Approximation Calculation. Micromachines (Basel) 2023; 14:mi14051009. [PMID: 37241632 DOI: 10.3390/mi14051009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/01/2023] [Accepted: 05/04/2023] [Indexed: 05/28/2023]
Abstract
Planning astigmatic correction is a complex task. Biomechanical simulation models are useful for predicting the effects of the physical procedure on the cornea. Algorithms based on these models allow preoperative planning and simulate the outcome of patient-specific treatment. The objective of this study was to develop a customised optimisation algorithm and determine the predictability of astigmatism correction by femtosecond laser arcuate incisions. In this study, biomechanical models and Gaussian approximation curve calculations were used for surgical planning. Thirty-four eyes with mild astigmatism were included, and corneal topographies were evaluated before and after femtosecond laser-assisted cataract surgery with arcuate incisions. The follow-up time was up to 6 weeks. Retrospective data showed a significant reduction in postoperative astigmatism. A total of 79.4% showed a postoperative astigmatic value less than 1 D. Clinical refraction was significantly reduced from -1.39 ± 0.79 D preoperatively to -0.86 ± 0.67 D postoperatively (p 0.02). A positive reduction in topographic astigmatism was also observed (p < 0.00). The best-corrected visual acuity increased postoperatively (p < 0.001). We can conclude that customised simulations based on corneal biomechanics are a valuable tool for correcting mild astigmatism with corneal incisions in cataract surgery to improve postoperative visual outcomes.
Collapse
Affiliation(s)
| | - Gabriele Thumann
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
| | - Martina Kropp
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
| | - Zeljka Cvejic
- Faculty of Sciences, Department of Physics, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia
| | - Bojan Pajic
- Eye Clinic ORASIS, Swiss Eye Research Foundation, 5734 Reinach, Switzerland
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
- Faculty of Sciences, Department of Physics, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
| |
Collapse
|
3
|
Slezak F, Thumann G, Kropp M, Cvejic Z, De Clerck EEB, Bravetti GE, Guber I, Pajic B. Comparison of Conventional and Femtosecond Laser-Assisted Cataract Surgery Regarding Macula Behavior and Thickness. Medicina (Kaunas) 2023; 59:medicina59040639. [PMID: 37109597 PMCID: PMC10145739 DOI: 10.3390/medicina59040639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/05/2023] [Accepted: 03/21/2023] [Indexed: 04/29/2023]
Abstract
Background: The aim of the study was to compare macular thickness behavior and clinical outcomes after femtosecond laser-assisted cataract surgery (FLACS) versus phacoemulsification conventional surgery (PCS). Methods: Macular Optical Coherence Tomography OCT was analyzed in 42 patients preoperatively, 1 day, 12 days, 4 weeks and 6 weeks postoperatively according to the 9-field Early Treatment Diabetic Retinopathy Study (ETDRS) grid. Clinical findings were collected in both the FLACS group and the PCS group. Results: There was no significant difference in macular thickness between the FLACS and PCS groups (p > 0.05). However, from postoperative day 12 onwards, there was a significant increase in macular thickness observed in both groups (p < 0.001). In the FLACS group, a significant increase in visual acuity was observed on the first postoperative day, as compared to the PCS group (p = 0.006). Conclusions: The use of a low-energy high-frequency femtosecond laser has potentially no effect on postoperative macular thickness. In the FLACS group, visual rehabilitation was significantly faster as compared to the PCS group. No complications occurred intraoperatively in either group.
Collapse
Affiliation(s)
- Filip Slezak
- Eye Clinic ORASIS, Swiss Eye Research Foundation, 5734 Reinach, Switzerland
| | - Gabriele Thumann
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
| | - Martina Kropp
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
| | - Zeljka Cvejic
- Faculty of Sciences, Department of Physics, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia
| | - Eline Elodie Barbara De Clerck
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
| | - Giorgio Enrico Bravetti
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
| | - Ivo Guber
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
| | - Bojan Pajic
- Eye Clinic ORASIS, Swiss Eye Research Foundation, 5734 Reinach, Switzerland
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Experimental Ophthalmology, University of Geneva, 1205 Geneva, Switzerland
- Faculty of Sciences, Department of Physics, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
| |
Collapse
|
4
|
Pajic B, Pajic-Eggspuehler B, Cvejic Z, Rathjen C, Ruff V. First Clinical Results of a New Generation of Ablative Solid-State Lasers. J Clin Med 2023; 12:jcm12020731. [PMID: 36675659 PMCID: PMC9860716 DOI: 10.3390/jcm12020731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 01/09/2023] [Accepted: 01/12/2023] [Indexed: 01/18/2023] Open
Abstract
In the early 2000s, solid-state lasers emerged as an alternative technology to excimer systems in refractive surgery. Despite some technological limits at the time, good clinical results could be achieved with solid-state laser systems. This prospective case series reports clinical outcomes of five eyes treated with a newly developed solid-state laser system (AquariuZ) in three patients. Patients underwent preoperative examination, including corneal topo-and tomography, aberrometry, and confocal microscopy. All patients received a femtosecond LASIK with the Ziemer LDV Z8, a refractive treatment with the AquariuZ solid-state ablation laser, and were then followed up for a period of up to 12 months. The applied aspheric optimized profiles did not induce higher-order aberrations nor spherical aberration in any of these operated subjects. No eye lost BCVA lines throughout the duration of the follow-up. Six months after surgery, the safety index of patient 1 was 5, and for patients 2 and 3, it equaled 1. Confocal laser microscopy imaging findings were comparable to those seen typically for excimer lasers. The obtained results are encouraging and confirm that the new solid-state laser system is safe.
Collapse
Affiliation(s)
- Bojan Pajic
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach, Switzerland
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
- Correspondence: ; Tel.: +41-62-765-6080
| | | | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia
| | | | - Viktor Ruff
- Ziemer Ophthalmic Systems, 2562 Port, Switzerland
| |
Collapse
|
5
|
Pajic B, Massa H, Baenninger PB, Eskina E, Pajic-Eggspuehler B, Resan M, Cvejic Z. Multifocal Femto-PresbyLASIK in Pseudophakic Eyes. J Clin Med 2021; 10:jcm10112282. [PMID: 34070242 PMCID: PMC8197358 DOI: 10.3390/jcm10112282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 05/16/2021] [Accepted: 05/21/2021] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Presbyopia treatment in pseudophakic patients with a monofocal IOL is challenging. This study investigates the refractive results of femto-PresbyLASIK and analyzes presbyopia treatment in pseudophakic eyes. METHODS 14 patients with 28 pseudophakic eyes were treated with femto-PresbyLASIK. The dominant eye was targeted at a distance and the non-dominant eye at -0.5 D. The presbyopic algorithm creates a steepness in the cornea center by using an excimer laser that leads to corneal multifocality. RESULTS 6 months after surgery a refraction of -0.11 ± 0.13 D (p = 0.001), an uncorrected distance visual acuity of 0.05 ± 1.0 logMAR (p < 0.001) and an uncorrected near visual acuity of 0.15 ± 0.89 logMAR (p = 0.001) were achieved in the dominant eye. For the non-dominant eye, the refraction was -0.28 ± 0.22 D (p = 0.002), the uncorrected distance of visual acuity was 0.1 ± 1.49 logMAR, and the uncorrected near visual acuity was 0.11 ± 0.80 logMAR (p < 0.001). Spherical aberrations (Z400) were reduced by 0.21-0.3 µm in 32% of eyes, and by 0.31-0.4 µm in 26% of eyes. CONCLUSION By steepening the central cornea while maintaining spherical aberrations within acceptable limits, PresbyLASIK created a corneal multifocality that safely improved near vision in both eyes. Thus, femto-PresbyLASIK can be used to treat presbyopia in pseudophakic eyes without performing intraocular surgery.
Collapse
Affiliation(s)
- Bojan Pajic
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach, Switzerland;
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia;
- Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, 1205 Geneva, Switzerland;
- Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia;
- Correspondence: ; Tel.: +41-62-765-60-80
| | - Horace Massa
- Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, 1205 Geneva, Switzerland;
| | - Philipp B. Baenninger
- Cantonal Hospital of Lucerne, Department of Ophthalmology, 6006 Lucerne, Switzerland;
| | - Erika Eskina
- Ophthalmological Department of Academy of Postgraduate Education FSBF FRCC of the FMBA of Russia, 125310 Moscow, Russia;
- Laser Surgery Clinic “SPHERE”, 117628 Moscow, Russia
| | | | - Mirko Resan
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia;
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia;
| |
Collapse
|
6
|
Goles N, Nerancic M, Konjik S, Pajic-Eggspuehler B, Pajic B, Cvejic Z. Phacoemulsification and IOL-Implantation without Using Viscoelastics: Combined Modeling of Thermo Fluid Dynamics, Clinical Outcomes, and Endothelial Cell Density. Sensors (Basel) 2021; 21:s21072399. [PMID: 33808502 PMCID: PMC8037460 DOI: 10.3390/s21072399] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 03/13/2021] [Accepted: 03/19/2021] [Indexed: 11/16/2022]
Abstract
Phacoemulsification is a widely used surgical method in cataract surgery with a high energy ultrasound source. The viscoelastic is considered to be tissue protective. The aim of this study is to investigate during surgery the impact of using viscoelastic versus no viscoelastic on clinical outcomes, potential complications and effect on endothelial cell density. The study group included 64 patients, who were subjected to phacoemulsification using balanced salt solution (BSS). Control group consisted of 62 patients, who underwent phacoemulsification using Hyaloronic acid 1% Healon 1%. Student’s t-test was applied for statistical analysis. The simulations of temperature changes during phacoemulsification were performed by COMSOL Multiphysics software. In the BSS group, a mean endothelial cell loss (ECL) of 4.5% was measured one month postoperatively, while in the Healon group ECL was 5.3%. Data analysis showed no significant difference in ECL between the groups (Student’s t-test, p = 0.8). No significant difference was observed in endothelial cell morphology and IOP between the two groups pre- and postoperatively (all p > 0.05). The modeling of thermo fluid dynamics showed that the heating of the cornea is slightly less when Healon was used as irrigation fluid. The phacoemulsification technique can be performed by an experienced surgeon with viscoelastics or continuous anterior chamber (AC) irrigation on the same level of safety regarding endothelial cell damage, providing equally satisfying clinical outcomes.
Collapse
Affiliation(s)
- Nikola Goles
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia; (N.G.); (M.N.); (B.P.)
| | - Marko Nerancic
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia; (N.G.); (M.N.); (B.P.)
| | - Sanja Konjik
- Department of Mathematics and Informatics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia;
| | | | - Bojan Pajic
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia; (N.G.); (M.N.); (B.P.)
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach AG, Switzerland;
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, 21000 Novi Sad, Serbia; (N.G.); (M.N.); (B.P.)
- Correspondence:
| |
Collapse
|
7
|
Schroeter A, Kropp M, Cvejic Z, Thumann G, Pajic B. Comparison of Femtosecond Laser-Assisted and Ultrasound-Assisted Cataract Surgery with Focus on Endothelial Analysis. Sensors (Basel) 2021; 21:s21030996. [PMID: 33540680 PMCID: PMC7867300 DOI: 10.3390/s21030996] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 01/26/2021] [Accepted: 01/29/2021] [Indexed: 12/11/2022]
Abstract
Femtosecond laser-assisted cataract surgery has the potential to make critical steps of cataract surgery easier and safer, and reduce endothelial cell loss, thus, improving postoperative outcomes. This study compared FLACS with the conventional method in terms of endothelial cells behavior, clinical outcomes, and capsulotomy precision. METHODS In a single-center, randomized controlled study, 130 patients with cataracta senilis received FLACS or conventional cataract surgery. RESULTS A significant endothelial cell loss was observed postoperatively, compared to the preoperative values in both groups. The endothelial cell counts was significantly better in the FLACS group in cataract grade 2 (p = 0.048) patients, compared to conventionally at 4 weeks. The effective phaco time was notably shorter in grade 2 of the FLACS group (p = 0.007) compared to the conventional. However, no statistically significant differences were found for the whole sample, including all cataract grades, due to the overall cataract density in the FLACS group being significantly higher (2.60 ± 0.58, p < 0.001) as compared to conventional methods (2.23 ± 0.42). CONCLUSIONS Low energy FLACS provides a better result compared to endothelial cell loss, size, and shape variations, as well as in effective phaco time within certain cataract grade subgroups. A complete comparison between two groups was not possible because of the higher cataract grade in the FLACS. FLACS displayed a positive effect on endothelial cell preservation and was proven to be much more precise.
Collapse
Affiliation(s)
- Anna Schroeter
- Department of Ophthalmology, Basel University Hospital, Mittlerestr str. 91, 4056 Basel, Switzerland;
| | - Martina Kropp
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland; (M.K.); (G.T.)
- Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia;
| | - Gabriele Thumann
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland; (M.K.); (G.T.)
- Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland
| | - Bojan Pajic
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland; (M.K.); (G.T.)
- Faculty of Medicine, University of Geneva, 1205 Geneva, Switzerland
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia;
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach, Switzerland
- Faculty of Medicine of the Military Medical Academy, University of Defence, 11000 Belgrade, Serbia
- Correspondence: ; Tel.: +41-62-765-60-80
| |
Collapse
|
8
|
Rigendinger F, Aebersold DM, Cvejic Z, Pajic B. Changes of Corneal Biomechanical Properties upon Exclusive Ytt-/Sr-90 Irradiation of Pterygium. Sensors (Basel) 2021; 21:s21030975. [PMID: 33540506 PMCID: PMC7867194 DOI: 10.3390/s21030975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 01/20/2021] [Accepted: 01/26/2021] [Indexed: 11/16/2022]
Abstract
BACKGROUND It is known that pterygia above a certain size cause astigmatism and other aberrations of the human cornea and thus impair the quality of vision. Exclusive Sr-/Ytt-90 beta irradiation is a highly effective treatment for primary pterygia. The aim of this retrospective study is to determine the extent to which higher order corneal aberrations are affected by this treatment. METHODS Evaluation of corneal topographies and wavefront aberration data of 20 primary pterygia patients generated before and at different points in time in the first year after irradiation. Additionally, the size of the pterygium was measured. RESULTS The study showed a significant increase in coma and triple leaf aberrations in pterygia with a horizontal length of 2 mm and more. It was also found that a pterygium size greater than 2 mm significantly induces astigmatism. Both phenomena reduce visual quality. In none of the patients could a pterygium recurrence be detected after irradiation. CONCLUSIONS If the pterygium size is less than 2 mm, early exclusive Sr/Ytt-90 beta irradiation can be recommended. If the size is more than 2 mm, a pterygium excision 6 months after beta irradiation can be discussed.
Collapse
Affiliation(s)
- Fritz Rigendinger
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach AG, Switzerland;
| | - Daniel M. Aebersold
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, 3012 Bern, Switzerland;
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia;
| | - Bojan Pajic
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach AG, Switzerland;
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia;
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, 1205 Geneva, Switzerland
- Faculty of Medicine of the Military Medical Academy, University of Defense, 11000 Belgrade, Serbia
- Correspondence: ; Tel.: +41-62-765-60-80
| |
Collapse
|
9
|
Pajic B, Cvejic Z, Pajic-Eggspuehler B. Cataract Surgery Performed by High Frequency LDV Z8 Femtosecond Laser: Safety, Efficacy, and Its Physical Properties. Sensors (Basel) 2017. [PMID: 28629164 PMCID: PMC5492121 DOI: 10.3390/s17061429] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: The aim of our study was to investigate the safety and efficacy of the LDV Z8 femtosecond laser in cataract surgery compared to the conventional procedure. Methods: This prospective study was performed at the Swiss Eye Research Foundation, Eye Clinic ORASIS, Reinach, Switzerland. The study included 130 eyes from 130 patients: 68 treated with femtosecond laser-assisted cataract surgery (FLACS) using the FEMTO LDV Z8 and 62 treated with conventional phacoemulsification. Capsulotomy and lens fragmentation in the laser group were performed with the FEMTO LDV Z8 femtosecond laser system, which employs a new, low-energy, high repetition rate laser process for cataract surgery. In the conventional group, the capsulotomy was performed by a cystotome, and lens fragmentation was achieved by the stop-and-chop. Results: Ease of phacoemulsification (on a 4-point scale), the completeness of capsulotomy (on a 10-point scale), effective phacoemulsification time (seconds), uncorrected distance visual acuity (UCVA), best spectacle-corrected distance visual acuity (BSCVA), spherical equivalent (SE), and safety of the procedure were evaluated. The total follow-up time was three months. Conclusions: FLACS with the FEMTO LDV Z8 system was characterized by complete and reproducible capsulotomy and highly effective lens fragmentation. Postoperative visual outcomes were excellent, and the safety of the procedure was optimal.
Collapse
Affiliation(s)
- Bojan Pajic
- Eye Clinic Orasis, Swiss Eye Research Foundation, 5734 Reinach AG, Switzerland.
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia.
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, 1205 Genève, Switzerland.
- Faculty of Medicine of the Military Medical academy, University of Defense, 11000 Belgrade, Serbia.
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovica 4, 21000 Novi Sad, Serbia.
| | | |
Collapse
|
10
|
Abstract
PURPOSE Pterygium is a common lesion affecting the population in countries with high levels of ultraviolet exposure. The final shape of a pterygium is the result of a growth pattern, which remains poorly understood. This manuscript provides a mathematical analysis as a tool to determine the shape of human pterygia. MATERIALS AND METHODS Eighteen patients, all affected by nasal unilateral pterygia, were randomly selected from our patient database independently of sex, origin, or race. We included all primary or recurrent pterygia with signs of proliferation, dry eye, and induction of astigmatism. Pseudopterygia were excluded from this study. Pterygia were outlined and analyzed mathematically using a Cartesian coordinate system with two axes (X, Y) and five accurate landmarks of the pterygium. RESULTS In 13 patients (72%), the shape of the pterygia was hyperbolic and in five patients (28%), the shape was rather elliptical. CONCLUSION This analysis gives a highly accurate mathematical description of the shape of human pterygia. This might help to better assess the clinical results and outcome of the great variety of therapeutic approaches concerning these lesions.
Collapse
Affiliation(s)
- Bojan Pajic
- Eye Clinic ORASIS, Swiss Eye Research Foundation, Reinach AG, Switzerland
- Department of Physics, Faculty of Sciences, University of Novi Sad, Novi Sad
- Faculty of Medicine of the Military Medical Academy, University of Defence, Belgrade, Serbia
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, Geneva, Switzerland
| | - Iraklis Vastardis
- Eye Clinic ORASIS, Swiss Eye Research Foundation, Reinach AG, Switzerland
| | - Predrag Rajkovic
- Department of Mathematics, Faculty of Mechanical Engineering, University of Niš, Niš, Serbia
| | | | - Daniel M Aebersold
- Department of Radiation Oncology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Zeljka Cvejic
- Department of Physics, Faculty of Sciences, University of Novi Sad, Novi Sad
| |
Collapse
|
11
|
Vastardis I, Pajic-Eggspühler B, Müller J, Cvejic Z, Pajic B. Femtosecond laser-assisted in situ keratomileusis multifocal ablation profile using a mini-monovision approach for presbyopic patients with hyperopia. Clin Ophthalmol 2016; 10:1245-56. [PMID: 27478365 PMCID: PMC4951058 DOI: 10.2147/opth.s102008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose To report the visual outcomes of the femtosecond laser-assisted multifocal aspheric corneal ablation profile using a mini-monovision approach and to evaluate if corneal multifocality was effective, and to report the relative benefits of this approach. Patients and methods Bilateral femtosecond laser-assisted in situ keratomileusis using a multifocal aspheric corneal ablation profile was performed on 19 hyperopic patients (38 eyes). They were divided into two groups based on eye dominance: dominant eye (DE) group targeting emmetropia and the nondominant eye (NDE) group targeting −0.5 D slight myopia. The uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and retreatment rates were reported from baseline to 6 months. Results The UNVA, UIVA, and UDVA improved significantly in both groups (Kruskal–Wallis test, DE and NDE: P<0.00001, P<0.000005, and P=0.00001, respectively). Corrected distance visual acuity (CDVA) baseline was better in both groups in comparison to UDVA at 6 months (Wilcoxon test, DE: P<0.001, 95% confidence interval (CI) of the median 0.0–0.0 LogMAR and 0.1000–0.1218 LogMAR and NDE: P=0.010, 95% CI of the median 0.0–0.0 LogMAR and 0.00–0.10 LogMAR). There was a significant loss of lines between CDVA baseline and UDVA at 6 months in both groups (DE group: 68% of eyes lost one line or more; NDE group: 58% of eyes lost one line or more). The corrected near visual acuity baseline compared to UNVA at 6 months was not statistically important (Wilcoxon test, DE: P=0.8125, 95% CI of the median 0.0–0.0 LogMAR and 0.0–0.0 LogMAR and NDE: P=0.82, 95% CI of the median 0.0–0.0 LogMAR and 0.0–0.0 LogMAR). The comparison among the UDVA, UIVA, and UNVA between the two groups at baseline and during all follow-ups was not statistically important. Two cases from the DE group were retreated (6%). Conclusion Use of this multifocal aspheric corneal ablation profile in patients with hyperopic presbyopia significantly improved UDVA, UIVA, and UNVA. This improvement was due to created multifocality of the cornea. The mini-monovision seems not to affect UDVA, UIVA, and UNVA between the two groups. The retreatment rates at the 6-month evaluation were significantly less in our study when compared with other studies. This method seems to improve UDVA, UIVA, and UNVA but could result in a significant statistical difference between CDVA baseline and UDVA at 6 months that leads to loss of lines in distance vision. Despite promising results, this is a preliminary evaluation of this new profile, and a larger number of eyes are needed to verify visual outcomes, retreatment rates, and safety.
Collapse
Affiliation(s)
- Iraklis Vastardis
- Swiss Eye Research Foundation, Orasis Eye Clinic, Aargau, Reinach, Switzerland
| | | | - Jörg Müller
- Swiss Eye Research Foundation, Orasis Eye Clinic, Aargau, Reinach, Switzerland; Faculty of Physics, University of Novi Sad, Novi Sad, Serbia
| | - Zeljka Cvejic
- Faculty of Physics, University of Novi Sad, Novi Sad, Serbia
| | - Bojan Pajic
- Swiss Eye Research Foundation, Orasis Eye Clinic, Aargau, Reinach, Switzerland; Faculty of Physics, University of Novi Sad, Novi Sad, Serbia; Department of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland; Medical Faculty, Military Medical Academy, University of Defence, Belgrade, Serbia
| |
Collapse
|
12
|
Ganezer K, Krmar M, Cvejic Z, Rakic S, Pajic B. SU-E-I-44: Some Preliminary Analysis of Angular Distribution of X-Ray Scattered On Soft Tissues. Med Phys 2015. [DOI: 10.1118/1.4924041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|