1
|
Yang Y, Yuan T, Rodriguez Y Baena F, Dini D, Zhan W. Effect of infusion direction on convection-enhanced drug delivery to anisotropic tissue. J R Soc Interface 2024; 21:20240378. [PMID: 39353562 PMCID: PMC11444765 DOI: 10.1098/rsif.2024.0378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 08/12/2024] [Accepted: 08/13/2024] [Indexed: 10/04/2024] Open
Abstract
Convection-enhanced delivery (CED) can effectively overcome the blood-brain barrier by infusing drugs directly into diseased sites in the brain using a catheter, but its clinical performance still needs to be improved. This is strongly related to the highly anisotropic characteristics of brain white matter, which results in difficulties in controlling drug transport and distribution in space. In this study, the potential to improve the delivery of six drugs by adjusting the placement of the infusion catheter is examined using a mathematical model and accurate numerical simulations that account simultaneously for the interstitial fluid (ISF) flow and drug transport processes in CED. The results demonstrate the ability of this direct infusion to enhance ISF flow and therefore facilitate drug transport. However, this enhancement is highly anisotropic, subject to the orientation of local axon bundles and is limited within a small region close to the infusion site. Drugs respond in different ways to infusion direction: the results of our simulations show that while some drugs are almost insensitive to infusion direction, this strongly affects other compounds in terms of isotropy of drug distribution from the catheter. These findings can serve as a reference for planning treatments using CED.
Collapse
Affiliation(s)
- Yi Yang
- School of Engineering, University of Aberdeen, Aberdeen, UK
| | - Tian Yuan
- Department of Mechanical Engineering, Imperial College London, London, UK
| | | | - Daniele Dini
- Department of Mechanical Engineering, Imperial College London, London, UK
| | - Wenbo Zhan
- School of Engineering, University of Aberdeen, Aberdeen, UK
| |
Collapse
|
2
|
Yuan T, Zhan W, Terzano M, Holzapfel GA, Dini D. A comprehensive review on modeling aspects of infusion-based drug delivery in the brain. Acta Biomater 2024; 185:1-23. [PMID: 39032668 DOI: 10.1016/j.actbio.2024.07.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 07/10/2024] [Accepted: 07/11/2024] [Indexed: 07/23/2024]
Abstract
Brain disorders represent an ever-increasing health challenge worldwide. While conventional drug therapies are less effective due to the presence of the blood-brain barrier, infusion-based methods of drug delivery to the brain represent a promising option. Since these methods are mechanically controlled and involve multiple physical phases ranging from the neural and molecular scales to the brain scale, highly efficient and precise delivery procedures can significantly benefit from a comprehensive understanding of drug-brain and device-brain interactions. Behind these interactions are principles of biophysics and biomechanics that can be described and captured using mathematical models. Although biomechanics and biophysics have received considerable attention, a comprehensive mechanistic model for modeling infusion-based drug delivery in the brain has yet to be developed. Therefore, this article reviews the state-of-the-art mechanistic studies that can support the development of next-generation models for infusion-based brain drug delivery from the perspective of fluid mechanics, solid mechanics, and mathematical modeling. The supporting techniques and database are also summarized to provide further insights. Finally, the challenges are highlighted and perspectives on future research directions are provided. STATEMENT OF SIGNIFICANCE: Despite the immense potential of infusion-based drug delivery methods for bypassing the blood-brain barrier and efficiently delivering drugs to the brain, achieving optimal drug distribution remains a significant challenge. This is primarily due to our limited understanding of the complex interactions between drugs and the brain that are governed by principles of biophysics and biomechanics, and can be described using mathematical models. This article provides a comprehensive review of state-of-the-art mechanistic studies that can help to unravel the mechanism of drug transport in the brain across the scales, which underpins the development of next-generation models for infusion-based brain drug delivery. More broadly, this review will serve as a starting point for developing more effective treatments for brain diseases and mechanistic models that can be used to study other soft tissue and biomaterials.
Collapse
Affiliation(s)
- Tian Yuan
- Department of Mechanical Engineering, Imperial College London, SW7 2AZ, UK.
| | - Wenbo Zhan
- School of Engineering, University of Aberdeen, Aberdeen, AB24 3UE, UK
| | - Michele Terzano
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering, NTNU, Trondheim, Norway
| | - Daniele Dini
- Department of Mechanical Engineering, Imperial College London, SW7 2AZ, UK.
| |
Collapse
|
3
|
Wan Y, González-Cruz RD, Hoffman-Kim D, Kesari H. A mechanics theory for the exploration of a high-throughput, sterile 3D in vitro traumatic brain injury model. Biomech Model Mechanobiol 2024; 23:1179-1196. [PMID: 38970736 DOI: 10.1007/s10237-024-01832-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 02/19/2024] [Indexed: 07/08/2024]
Abstract
Brain injuries resulting from mechanical trauma represent an ongoing global public health issue. Several in vitro and in vivo models for traumatic brain injury (TBI) continue to be developed for delineating the various complex pathophysiological processes involved in its onset and progression. Developing an in vitro TBI model that is based on cortical spheroids is especially of great interest currently because they can replicate key aspects of in vivo brain tissue, including its electrophysiology, physicochemical microenvironment, and extracellular matrix composition. Being able to mechanically deform the spheroids are a key requirement in any effective in vitro TBI model. The spheroids' shape and size, however, make mechanically loading them, especially in a high-throughput, sterile, and reproducible manner, quite challenging. To address this challenge, we present an idea for a spheroid-based, in vitro TBI model in which the spheroids are mechanically loaded by being spun by a centrifuge. (An experimental demonstration of this new idea will be published shortly elsewhere.) An issue that can limit its utility and scope is that imaging techniques used in 2D and 3D in vitro TBI models cannot be readily applied in it to determine spheroid strains. In order to address this issue, we developed a continuum mechanics-based theory to estimate the spheroids' strains when they are being spun at a constant angular velocity. The mechanics theory, while applicable here to a special case of the centrifuge-based TBI model, is also of general value since it can help with the further exploration and development of TBI models.
Collapse
Affiliation(s)
- Yang Wan
- School of Engineering, Brown University, Providence, RI, 02912, USA
| | - Rafael D González-Cruz
- Department of Neuroscience, Brown University, Providence, RI, 02912, USA
- Robert J. and Nancy D. Carney Institute for Brain Science, Brown University, Providence, RI, 02906, USA
| | - Diane Hoffman-Kim
- Department of Neuroscience, Brown University, Providence, RI, 02912, USA
- Robert J. and Nancy D. Carney Institute for Brain Science, Brown University, Providence, RI, 02906, USA
- Center for Biomedical Engineering, Brown University, Providence, RI, 02912, USA
| | - Haneesh Kesari
- School of Engineering, Brown University, Providence, RI, 02912, USA.
| |
Collapse
|
4
|
Yuan T, Shen L, Dini D. Porosity-permeability tensor relationship of closely and randomly packed fibrous biomaterials and biological tissues: Application to the brain white matter. Acta Biomater 2024; 173:123-134. [PMID: 37979635 DOI: 10.1016/j.actbio.2023.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 10/09/2023] [Accepted: 11/06/2023] [Indexed: 11/20/2023]
Abstract
The constitutive model for the porosity-permeability relationship is a powerful tool to estimate and design the transport properties of porous materials, which has attracted significant attention for the advancement of novel materials. However, in comparison with other materials, biomaterials, especially natural and artificial tissues, have more complex microstructures e.g. high anisotropy, high randomness of cell/fibre dimensions/position and very low porosity. Consequently, a reliable microstructure-permeability relationship of fibrous biomaterials has proven elusive. To fill this gap, we start a mathematical derivation from the fundamental brain white matter (WM) formed by nerve fibres. This is augmented by a numerical characterisation and experimental validations to obtain an anisotropic permeability tensor of the brain WM as a function of the tissue porosity. A versatile microstructure generation software (MicroFiM) for fibrous biomaterial with complex microstructure and low porosity was built accordingly and made freely accessible here. Moreover, we propose an anisotropic poro-hyperelastic model enhanced by the newly defined porosity-permeability tensor relationship which precisely captures the tissues macro-scale permeability changes due to the microstructural deformation in an infusion scenario. The constitutive model, theories and protocols established in this study will both provide improved design strategies to tailor the transport properties of fibrous biomaterials and enable the non-invasive characterisation of the transport properties of biological tissues. This will lead to the provision of better patient-specific medical treatments, such as drug delivery. STATEMENT OF SIGNIFICANCE: Due to the microstructural complexity, a reliable microstructure-permeability relationship of fibrous biomaterials has proven elusive, which hinders our way of tuning the fluid transport property of the biomaterials by directly programming their microstructure. The same problem hinders non-invasive characterisations of fluid transport properties in biological tissues, which can significantly improve the efficiency of treatments e.g. drug delivery, directly from the tissues accessible microstructural information, e.g. porosity. Here, we developed a validated mathematical formulation to link the random microstructure to a fibrous material's macroscale permeability tensor. This will advance our capability to design complex biomaterials and make it possible to non-invasively characterise the permeability of living tissues for precise treatment planning. The newly established theory and protocol can be easily adapted to various types of fibrous biomaterials.
Collapse
Affiliation(s)
- Tian Yuan
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
| | - Li Shen
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - Daniele Dini
- Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
| |
Collapse
|
5
|
de Lucio M, Leng Y, Wang H, Ardekani AM, Vlachos PP, Shi G, Gomez H. Computational modeling of the effect of skin pinch and stretch on subcutaneous injection of monoclonal antibodies using autoinjector devices. Biomech Model Mechanobiol 2023; 22:1965-1982. [PMID: 37526775 DOI: 10.1007/s10237-023-01746-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 07/06/2023] [Indexed: 08/02/2023]
Abstract
Subcutaneous injection of monoclonal antibodies (mAbs) has experienced unprecedented growth in the pharmaceutical industry due to its benefits in patient compliance and cost-effectiveness. However, the impact of different injection techniques and autoinjector devices on the drug's transport and uptake is poorly understood. Here, we develop a biphasic large-deformation chemomechanical model that accounts for the components of the extracellular matrix that govern solid deformation and fluid flow within the subcutaneous tissue: interstitial fluid, collagen fibers and negatively charged proteoglycan aggregates. We use this model to build a high-fidelity representation of a virtual patient performing a subcutaneous injection of mAbs. We analyze the impact of the pinch and stretch methods on the injection dynamics and the use of different handheld autoinjector devices. The results suggest that autoinjector base plates with a larger device-skin contact area cause significantly lower tissue mechanical stress, fluid pressure and fluid velocity during the injection process. Our simulations indicate that the stretch technique presents a higher risk of intramuscular injection for autoinjectors with a relatively long needle insertion depth.
Collapse
Affiliation(s)
- Mario de Lucio
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Yu Leng
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Hao Wang
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Arezoo M Ardekani
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Pavlos P Vlachos
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Galen Shi
- Eli Lilly and Company, Indianapolis, IN, USA
| | - Hector Gomez
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA.
| |
Collapse
|
6
|
Gholampour S. Why Intracranial Compliance Is Not Utilized as a Common Practical Tool in Clinical Practice. Biomedicines 2023; 11:3083. [PMID: 38002083 PMCID: PMC10669292 DOI: 10.3390/biomedicines11113083] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 11/14/2023] [Accepted: 11/15/2023] [Indexed: 11/26/2023] Open
Abstract
Intracranial compliance (ICC) holds significant potential in neuromonitoring, serving as a diagnostic tool and contributing to the evaluation of treatment outcomes. Despite its comprehensive concept, which allows consideration of changes in both volume and intracranial pressure (ICP), ICC monitoring has not yet established itself as a standard component of medical care, unlike ICP monitoring. This review highlighted that the first challenge is the assessment of ICC values, because of the invasive nature of direct measurement, the time-consuming aspect of non-invasive calculation through computer simulations, and the inability to quantify ICC values in estimation methods. Addressing these challenges is crucial, and the development of a rapid, non-invasive computer simulation method could alleviate obstacles in quantifying ICC. Additionally, this review indicated the second challenge in the clinical application of ICC, which involves the dynamic and time-dependent nature of ICC. This was considered by introducing the concept of time elapsed (TE) in measuring the changes in volume or ICP in the ICC equation (volume change/ICP change). The choice of TE, whether short or long, directly influences the ICC values that must be considered in the clinical application of the ICC. Compensatory responses of the brain exhibit non-monotonic and variable changes in long TE assessments for certain disorders, contrasting with the mono-exponential pattern observed in short TE assessments. Furthermore, the recovery behavior of the brain undergoes changes during the treatment process of various brain disorders when exposed to short and long TE conditions. The review also highlighted differences in ICC values across brain disorders with various strain rates and loading durations on the brain, further emphasizing the dynamic nature of ICC for clinical application. The insight provided in this review may prove valuable to professionals in neurocritical care, neurology, and neurosurgery for standardizing ICC monitoring in practical application related to the diagnosis and evaluation of treatment outcomes in brain disorders.
Collapse
Affiliation(s)
- Seifollah Gholampour
- Department of Neurological Surgery, University of Chicago, Chicago, IL 60637, USA
| |
Collapse
|
7
|
Yuan T, Zhan W, Dini D. Linking fluid-axons interactions to the macroscopic fluid transport properties of the brain. Acta Biomater 2023; 160:152-163. [PMID: 36781040 DOI: 10.1016/j.actbio.2023.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 01/25/2023] [Accepted: 02/06/2023] [Indexed: 02/13/2023]
Abstract
Many brain disorders, including Alzheimer's Disease and Parkinson's Disease, and drug delivery procedures are linked to fluid transport in the brain; yet, while neurons are extremely soft and can be easily deformed, how the microscale channel flow interacts with the neuronal structures (especially axons) deformation and how these interactions affect the macroscale tissue function and transport properties is poorly understood. Misrepresenting these relationships may lead to the erroneous prediction of e.g. disease spread, drug delivery, and nerve injury in the brain. However, understanding fluid-neuron interactions is an outstanding challenge because the behaviours of both phases are not only dynamic but also occur at an extremely small length scale (the width of the flow channel is ∼100 nm), which cannot be captured by state-of-the-art experimental techniques. Here, by explicitly simulating the dynamics of the flow and axons at the microstructural level, we, for the first time, establish the link between micromechanical tissue response to the physical laws governing the macroscopic transport property of the brain white matter. We found that interactions between axons and the interstitial flow are very strong, thus playing an essential role in the brain fluid/mass transport. Furthermore, we proposed the first anisotropic pressure-dependent permeability tensor informed by microstructural dynamics for more accurate brain modelling at the macroscale, and analysed the effect of the variation of the microstructural parameters that influence such tensor. These findings will shed light on some unsolved issues linked to brain functions and medical treatments relying on intracerebral transport, and the mathematical model provides a framework to more realistically model the brain and design brain-tissue-like biomaterials. STATEMENT OF SIGNIFICANCE: This study reveals how neurons interact with the fluid flowing around them and how these microscale interactions affect macroscale transport behaviour of the brain tissue. The findings provide unprecedented insights into some unsolved issues linked to brain functions and medical treatments relying on intracerebral fluid transport. Furthermore, we, for the first time, established a microstructure-informed permeability tensor as a function of local hydraulic pressure and pressure gradient for the brain tissue, which inherently captures the dynamic transport property of the brain. This study is a cornerstone to advance the predicting accuracy of brain tissue transport property and neural tissue engineering.
Collapse
Affiliation(s)
- Tian Yuan
- Department of Mechanical Engineering, Imperial College London, London, SW7 2AZ, UK.
| | - Wenbo Zhan
- School of Engineering, King's College, University of Aberdeen, Aberdeen, AB24 3UE, UK
| | - Daniele Dini
- Department of Mechanical Engineering, Imperial College London, London, SW7 2AZ, UK.
| |
Collapse
|
8
|
Mathematical Optimisation of Magnetic Nanoparticle Diffusion in the Brain White Matter. Int J Mol Sci 2023; 24:ijms24032534. [PMID: 36768857 PMCID: PMC9917052 DOI: 10.3390/ijms24032534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 01/20/2023] [Accepted: 01/26/2023] [Indexed: 01/31/2023] Open
Abstract
Magnetic nanoparticles (MNPs) are a promising drug delivery system to treat brain diseases, as the particle transport trajectory can be manipulated by an external magnetic field. However, due to the complex microstructure of brain tissues, particularly the arrangement of nerve fibres in the white matter (WM), how to achieve desired drug distribution patterns, e.g., uniform distribution, is largely unknown. In this study, by adopting a mathematical model capable of capturing the diffusion trajectories of MNPs, we conducted a pilot study to investigate the effects of key parameters in the MNP delivery on the particle diffusion behaviours in the brain WM microstructures. The results show that (i) a uniform distribution of MNPs can be achieved in anisotropic tissues by adjusting the particle size and magnetic field; (ii) particle size plays a key role in determining MNPs' diffusion behaviours. The magnitude of MNP equivalent diffusivity is reversely correlated to the particle size. The MNPs with a dimension greater than 90 nm cannot reach a uniform distribution in the brain WM even in an external magnitude field; (iii) axon tortuosity may lead to transversely anisotropic MNP transport in the brain WM; however, this effect can be mitigated by applying an external magnetic field perpendicular to the local axon track. This study not only advances understanding to answer the question of how to optimise MNP delivery, but also demonstrates the potential of mathematical modelling to help achieve desired drug distributions in biological tissues with a complex microstructure.
Collapse
|
9
|
Bernardini A, Trovatelli M, Kłosowski MM, Pederzani M, Zani DD, Brizzola S, Porter A, Rodriguez Y Baena F, Dini D. Reconstruction of ovine axonal cytoarchitecture enables more accurate models of brain biomechanics. Commun Biol 2022; 5:1101. [PMID: 36253409 PMCID: PMC9576772 DOI: 10.1038/s42003-022-04052-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 09/29/2022] [Indexed: 12/03/2022] Open
Abstract
There is an increased need and focus to understand how local brain microstructure affects the transport of drug molecules directly administered to the brain tissue, for example in convection-enhanced delivery procedures. This study reports a systematic attempt to characterize the cytoarchitecture of commissural, long association and projection fibres, namely the corpus callosum, the fornix and the corona radiata, with the specific aim to map different regions of the tissue and provide essential information for the development of accurate models of brain biomechanics. Ovine samples are imaged using scanning electron microscopy combined with focused ion beam milling to generate 3D volume reconstructions of the tissue at subcellular spatial resolution. Focus is placed on the characteristic cytological feature of the white matter: the axons and their alignment in the tissue. For each tract, a 3D reconstruction of relatively large volumes, including a significant number of axons, is performed and outer axonal ellipticity, outer axonal cross-sectional area and their relative perimeter are measured. The study of well-resolved microstructural features provides useful insight into the fibrous organization of the tissue, whose micromechanical behaviour is that of a composite material presenting elliptical tortuous tubular axonal structures embedded in the extra-cellular matrix. Drug flow can be captured through microstructurally-based models using 3D volumes, either reconstructed directly from images or generated in silico using parameters extracted from the database of images, leading to a workflow to enable physically-accurate simulations of drug delivery to the targeted tissue. Imaging and reconstruction of sheep brain axonal cytoarchitecture provides insight for brain biomechanics models that simulate drug delivery and other biological processes governed by interstitial fluid flow and transport.
Collapse
Affiliation(s)
- Andrea Bernardini
- Department of Mechanical Engineering, Imperial College London, London, SW7 2AZ, UK.
| | - Marco Trovatelli
- Faculty of Veterinary Medicine, Università degli Studi di Milano Statale, 26900, Lodi, Italy
| | | | - Matteo Pederzani
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy
| | - Davide Danilo Zani
- Faculty of Veterinary Medicine, Università degli Studi di Milano Statale, 26900, Lodi, Italy
| | - Stefano Brizzola
- Faculty of Veterinary Medicine, Università degli Studi di Milano Statale, 26900, Lodi, Italy
| | - Alexandra Porter
- Department of Materials, Imperial College London, London, SW7 2AZ, UK
| | | | - Daniele Dini
- Department of Mechanical Engineering, Imperial College London, London, SW7 2AZ, UK.
| |
Collapse
|