1
|
Schairer J, Plathe F, Hudelmaier S, Belau E, Pengelley S, Kruse L, Neusüß C. Ion mobility in gas and liquid phases: How much orthogonality is obtained in capillary electrophoresis-ion mobility-mass spectrometry? Electrophoresis 2024; 45:735-742. [PMID: 38085142 DOI: 10.1002/elps.202300210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/16/2023] [Accepted: 11/30/2023] [Indexed: 04/28/2024]
Abstract
Ion mobility-mass spectrometry (IM-MS) is an ever-evolving tool to separate ions in the gas phase according to electrophoretic mobility with subsequent mass determination. CE is rarely coupled to IM-MS, possibly due to similar separation mechanisms based on electrophoretic mobility. Here, we investigate the orthogonality of CE and ion mobility (IM) by analyzing a complex peptide mixture (tryptic digest of HeLa proteins) with trapped ion mobility mass spectrometry (TIMS-MS). Using the nanoCEasy interface, excellent sensitivity was achieved by identifying thousands of peptides and achieving a peak capacity of 7500 (CE: 203-323 in a 150 cm long capillary, IM: 27-31). Plotting CE versus mass and CE versus (inverse) mobility, a clear grouping in curved striped patterns is observed according to the charge-to-size and mass-to-charge ratios. The peptide charge in the acidic background electrolyte can be estimated from the number of basic amino acids, with a few exceptions where neighboring effects reduce the positive charge. A surprisingly high orthogonality of CE and IM is observed, which is obviously caused by solvation effects leading to different charges and sizes in the liquid phase compared to the gas phase. A high orthogonality of CE and ion mobility is expected to be observed for other peptide samples as well as other substance classes, making CE-IM-MS a promising tool for various applications.
Collapse
Affiliation(s)
- Jasmin Schairer
- Faculty of Chemistry, Aalen University, Aalen, Germany
- Faculty of Science, University of Tübingen, Tübingen, Germany
| | | | | | | | | | - Lena Kruse
- Faculty of Chemistry, Aalen University, Aalen, Germany
| | | |
Collapse
|
2
|
Pade LR, Stepler KE, Portero EP, DeLaney K, Nemes P. Biological mass spectrometry enables spatiotemporal 'omics: From tissues to cells to organelles. MASS SPECTROMETRY REVIEWS 2024; 43:106-138. [PMID: 36647247 PMCID: PMC10668589 DOI: 10.1002/mas.21824] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 09/14/2022] [Accepted: 09/17/2022] [Indexed: 06/17/2023]
Abstract
Biological processes unfold across broad spatial and temporal dimensions, and measurement of the underlying molecular world is essential to their understanding. Interdisciplinary efforts advanced mass spectrometry (MS) into a tour de force for assessing virtually all levels of the molecular architecture, some in exquisite detection sensitivity and scalability in space-time. In this review, we offer vignettes of milestones in technology innovations that ushered sample collection and processing, chemical separation, ionization, and 'omics analyses to progressively finer resolutions in the realms of tissue biopsies and limited cell populations, single cells, and subcellular organelles. Also highlighted are methodologies that empowered the acquisition and analysis of multidimensional MS data sets to reveal proteomes, peptidomes, and metabolomes in ever-deepening coverage in these limited and dynamic specimens. In pursuit of richer knowledge of biological processes, we discuss efforts pioneering the integration of orthogonal approaches from molecular and functional studies, both within and beyond MS. With established and emerging community-wide efforts ensuring scientific rigor and reproducibility, spatiotemporal MS emerged as an exciting and powerful resource to study biological systems in space-time.
Collapse
Affiliation(s)
- Leena R. Pade
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| | - Kaitlyn E. Stepler
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| | - Erika P. Portero
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| | - Kellen DeLaney
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| | - Peter Nemes
- Department of Chemistry & Biochemistry, University of Maryland, 8051 Regents Drive, College Park, MD 20742
| |
Collapse
|
3
|
Han M, Smith R, Rock DA. Capillary Electrophoresis-Mass Spectrometry (CE-MS) by Sheath-Flow Nanospray Interface and Its Use in Biopharmaceutical Applications. Methods Mol Biol 2022; 2531:15-47. [PMID: 35941476 DOI: 10.1007/978-1-0716-2493-7_2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Both capillary electrophoresis (CE) and mass spectrometry (MS) technologies are powerful analytical tools that have been used extensively in the characterization of biologics in the biopharmaceutical industry. The direct coupling of CE with MS is an attractive approach, in that the high separation capability of CE and the ultrasensitive detection and accurate identification performance of MS can be combined to provide a powerful system for the analysis of complex analytes. In this chapter, we discuss the detailed procedure of carrying out CE-MS analysis using a nano sheath-flow interface and its applications including intact mass analysis of monoclonal antibodies and fusion proteins, and a biotransformation study of two Fc-FGF21 molecules in a single-dose pharmacokinetic mice study. Optimization processes, including the finetuning of CE conditions and MS parameters, are illustrated in this chapter, with focuses on method robustness and assay reproducibility.
Collapse
Affiliation(s)
- Mei Han
- Pharmacokinetics and Drug Metabolism, Amgen Research, Amgen Inc., South San Francisco, CA, USA.
| | - Richard Smith
- Pharmacokinetics and Drug Metabolism, Amgen Research, Amgen Inc., South San Francisco, CA, USA
| | - Dan A Rock
- Pharmacokinetics and Drug Metabolism, Amgen Research, Amgen Inc., South San Francisco, CA, USA
| |
Collapse
|
4
|
Schlecht J, Stolz A, Hofmann A, Gerstung L, Neusüß C. nanoCEasy: An Easy, Flexible, and Robust Nanoflow Sheath Liquid Capillary Electrophoresis-Mass Spectrometry Interface Based on 3D Printed Parts. Anal Chem 2021; 93:14593-14598. [PMID: 34719920 DOI: 10.1021/acs.analchem.1c03213] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Capillary electrophoresis-mass spectrometry (CE-MS) is a powerful tool in various fields including proteomics, metabolomics, and biopharmaceutical and environmental analysis. Nanoflow sheath liquid (SL) CE-MS interfaces provide sensitive ionization, required in these fields, but are still limited to a few research laboratories as handling is difficult and expertise is necessary. Here, we introduce nanoCEasy, a novel nanoflow SL interface based on 3D printed parts, including our previously reported two capillary approach. The customized plug-and-play design enables the introduction of capillaries and an emitter without any fittings in less than a minute. The transparency of the polymer enables visual inspection of the liquid flow inside the interface. Robust operation was systematically demonstrated regarding the electrospray voltage, the distance between the emitter and MS orifice, the distance between the separation capillary and emitter tip, and different individual emitters of the same type. For the first time, we evaluated the influence of high electroosmotic flow (EOF) separation conditions on a nanoflow SL interface. A high flow from the separation capillary can be outbalanced by increasing the electrospray voltage, leading to an overall increased electrospray flow, which enables stable operation under high-EOF conditions. Overall, the nanoCEasy interface allows easy, sensitive, and robust coupling of CE-MS. We aspire the use of this sensitive, easy-to-use interface in large-scale studies and by nonexperts.
Collapse
Affiliation(s)
- Johannes Schlecht
- Department of Chemistry, Aalen University, Beethovenstrasse 1, 73430 Aalen, Germany.,Department of Pharmaceutical and Medicinal Chemistry, Friedrich Schiller University Jena, 07743 Jena, Germany
| | - Alexander Stolz
- Department of Chemistry, Aalen University, Beethovenstrasse 1, 73430 Aalen, Germany.,Department of Pharmaceutical and Medicinal Chemistry, Friedrich Schiller University Jena, 07743 Jena, Germany
| | - Adrian Hofmann
- Department of Chemistry, Aalen University, Beethovenstrasse 1, 73430 Aalen, Germany
| | - Lukas Gerstung
- Department of Chemistry, Aalen University, Beethovenstrasse 1, 73430 Aalen, Germany
| | - Christian Neusüß
- Department of Chemistry, Aalen University, Beethovenstrasse 1, 73430 Aalen, Germany
| |
Collapse
|
5
|
Abstract
Peptides play a crucial role in many vitally important functions of living organisms. The goal of peptidomics is the identification of the "peptidome," the whole peptide content of a cell, organ, tissue, body fluid, or organism. In peptidomic or proteomic studies, capillary electrophoresis (CE) is an alternative technique for liquid chromatography. It is a highly efficient and fast separation method requiring extremely low amounts of sample. In peptidomic approaches, CE is commonly combined with mass spectrometric (MS) detection. Most often, CE is coupled with electrospray ionization MS and less frequently with matrix-assisted laser desorption/ionization MS. CE-MS has been employed in numerous studies dealing with determination of peptide biomarkers in different body fluids for various diseases, or in food peptidomic research for the analysis and identification of peptides with special biological activities. In addition to the above topics, sample preparation techniques commonly applied in peptidomics before CE separation and possibilities for peptide identification and quantification by CE-MS or CE-MS/MS methods are discussed in this chapter.
Collapse
|
6
|
Mass spectrometry based metabolomics of volume-restricted in-vivo brain samples: Actual status and the way forward. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
7
|
Largy E, König A, Ghosh A, Ghosh D, Benabou S, Rosu F, Gabelica V. Mass Spectrometry of Nucleic Acid Noncovalent Complexes. Chem Rev 2021; 122:7720-7839. [PMID: 34587741 DOI: 10.1021/acs.chemrev.1c00386] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Nucleic acids have been among the first targets for antitumor drugs and antibiotics. With the unveiling of new biological roles in regulation of gene expression, specific DNA and RNA structures have become very attractive targets, especially when the corresponding proteins are undruggable. Biophysical assays to assess target structure as well as ligand binding stoichiometry, affinity, specificity, and binding modes are part of the drug development process. Mass spectrometry offers unique advantages as a biophysical method owing to its ability to distinguish each stoichiometry present in a mixture. In addition, advanced mass spectrometry approaches (reactive probing, fragmentation techniques, ion mobility spectrometry, ion spectroscopy) provide more detailed information on the complexes. Here, we review the fundamentals of mass spectrometry and all its particularities when studying noncovalent nucleic acid structures, and then review what has been learned thanks to mass spectrometry on nucleic acid structures, self-assemblies (e.g., duplexes or G-quadruplexes), and their complexes with ligands.
Collapse
Affiliation(s)
- Eric Largy
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Alexander König
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Anirban Ghosh
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Debasmita Ghosh
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Sanae Benabou
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| | - Frédéric Rosu
- Univ. Bordeaux, CNRS, INSERM, IECB, UMS 3033, F-33600 Pessac, France
| | - Valérie Gabelica
- Univ. Bordeaux, CNRS, INSERM, ARNA, UMR 5320, U1212, IECB, F-33600 Pessac, France
| |
Collapse
|
8
|
Investigating the position of the separation capillary and emitter tube tips in a nanoflow sheath-liquid CE-ESI-MS interface to decouple the ESI potential. Talanta 2021; 228:122212. [PMID: 33773698 DOI: 10.1016/j.talanta.2021.122212] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 02/08/2021] [Accepted: 02/09/2021] [Indexed: 12/11/2022]
Abstract
Robust decoupling of the ESI potential from the separation potential in CE-ESI-MS interfaces is very important for the high performance of the CE-ESI-MS devices and their applications for highly sensitive analyses of ionogenic compounds. In this study, we utilize a nanoflow sheath-liquid CE-ESI-MS interface composed of a quartz emitter and a separation fused silica capillary treated by etching, which are threaded to cross coupling for sheath liquid and electrode connection. Specifically, we have tested the ability of the interface to decouple the ESI potential from the separation potential at different positions of the separation capillary and ESI emitter tube tips. The interface with the separation capillary tip protruding the emitter tip by 20 μm did not provide sufficient robustness. The real ESI potential (delivered as 2.0 kV from the independent high voltage power supply HV2) ranged from 2.1 kV to 4.5 kV depending on the applied separation voltage (12.0-20.0 kV, provided by the power supply HV1) and electric conductivity of the background electrolyte (BGE) used. The interface robustness was partially improved when the capillary tip was aligned with the emitter tip. However, the complete decoupling of the spray and separation potentials was achieved only when the capillary tip was retracted 20 μm inside the emitter. In this arrangement, the ESI potential was stable and independent of both the separation potential (voltage) and the BGE conductivity. Moreover, this setting provided better sensitivity for the CE-ESI-MS analysis of selected drugs and benzylpyridinium cations than the setup with the capillary tip aligned with or protruding the emitter tip.
Collapse
|
9
|
Capillary Electrophoresis-Mass Spectrometry for Metabolomics: Possibilities and Perspectives. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1336:159-178. [PMID: 34628632 DOI: 10.1007/978-3-030-77252-9_9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Capillary electrophoresis-mass spectrometry (CE-MS) is a very useful analytical technique for the selective and highly efficient profiling of polar and charged metabolites in a wide range of biological samples. Compared to other analytical techniques, the use of CE-MS in metabolomics is relatively low as the approach is still regarded as technically challenging and not reproducible. In this chapter, the possibilities of CE-MS for metabolomics are highlighted with special emphasis on the use of recently developed interfacing designs. The utility of CE-MS for targeted and untargeted metabolomics studies is demonstrated by discussing representative and recent examples in the biomedical and clinical fields. The potential of CE-MS for large-scale and quantitative metabolomics studies is also addressed. Finally, some general conclusions and perspectives are given on this strong analytical separation technique for probing the polar metabolome.
Collapse
|
10
|
Cajic S, Hennig R, Burock R, Rapp E. Capillary (Gel) Electrophoresis-Based Methods for Immunoglobulin (G) Glycosylation Analysis. EXPERIENTIA SUPPLEMENTUM (2012) 2021; 112:137-172. [PMID: 34687009 DOI: 10.1007/978-3-030-76912-3_4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The in-depth characterization of protein glycosylation has become indispensable in many research fields and in the biopharmaceutical industry. Especially knowledge about modulations in immunoglobulin G (IgG) N-glycosylation and their effect on immunity enabled a better understanding of human diseases and the development of new, more effective drugs for their treatment. This chapter provides a deeper insight into capillary (gel) electrophoresis-based (C(G)E) glycan analysis, addressing its impressive performance and possibilities, its great potential regarding real high-throughput for large cohort studies, as well as its challenges and limitations. We focus on the latest developments with respect to miniaturization and mass spectrometry coupling, as well as data analysis and interpretation. The use of exoglycosidase sequencing in combination with current C(G)E technology is discussed, highlighting possible difficulties and pitfalls. The application section describes the detailed characterization of N-glycosylation, utilizing multiplexed CGE with laser-induced fluorescence detection (xCGE-LIF). Besides a comprehensive overview on antibody glycosylation by comparing species-specific IgGs and human immunoglobulins A, D, E, G, and M, the chapter comprises a comparison of therapeutic monoclonal antibodies from different production cell lines, as well as a detailed characterization of Fab and Fc glycosylation. These examples illustrate the full potential of C(G)E, resolving the smallest differences in sugar composition and structure.
Collapse
Affiliation(s)
- Samanta Cajic
- Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany
| | - René Hennig
- Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany.
- glyXera GmbH, Magdeburg, Germany.
| | | | - Erdmann Rapp
- Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, Germany
- glyXera GmbH, Magdeburg, Germany
| |
Collapse
|
11
|
Thomas SL, Thacker JB, Schug KA, Maráková K. Sample preparation and fractionation techniques for intact proteins for mass spectrometric analysis. J Sep Sci 2020; 44:211-246. [DOI: 10.1002/jssc.202000936] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 10/28/2020] [Accepted: 10/29/2020] [Indexed: 12/17/2022]
Affiliation(s)
- Shannon L. Thomas
- Department of Chemistry & Biochemistry The University of Texas Arlington Arlington Texas USA
| | - Jonathan B. Thacker
- Department of Chemistry & Biochemistry The University of Texas Arlington Arlington Texas USA
| | - Kevin A. Schug
- Department of Chemistry & Biochemistry The University of Texas Arlington Arlington Texas USA
| | - Katarína Maráková
- Department of Pharmaceutical Analysis and Nuclear Pharmacy Faculty of Pharmacy Comenius University in Bratislava Bratislava Slovakia
| |
Collapse
|
12
|
Wells SS, Dawod M, Kennedy RT. CE-MS with electrokinetic supercharging and application to determination of neurotransmitters. Electrophoresis 2019; 40:2946-2953. [PMID: 31502303 PMCID: PMC6947659 DOI: 10.1002/elps.201900203] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Revised: 09/03/2019] [Accepted: 09/05/2019] [Indexed: 12/31/2022]
Abstract
Electrokinetic supercharging (EKS) is known as one of the most effective online electrophoretic preconcentration techniques, though pairing with it with mass spectrometry has presented challenges. Here, EKS is successfully paired with ESI-MS/MS to provide a sensitive and robust method for analysis of biogenic amines in biological samples. Injection parameters including electric field strength and the buffer compositions used for the separation and focusing were investigated to achieve suitable resolution, high sensitivity, and compatibility with ESI-MS. Using EKS, the sensitivity of the method was improved 5000-fold compared to a conventional hydrodynamic injection with CZE. The separation allowed for baseline resolution of several neurotransmitters within 16 min with LODs down to 10 pM. This method was applied to targeted analysis of seven biogenic amines from rat brain stem and whole Drosophila tissue. This is the first method to use EKS with CE-ESI-MS/MS to analyze biological samples.
Collapse
Affiliation(s)
- Shane S Wells
- Department of Chemistry, University of Michigan, Ann Arbor, MI, USA
| | - Mohamed Dawod
- Department of Chemistry, University of Michigan, Ann Arbor, MI, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
13
|
Suzuki-Iwashima A, Matsuura H, Iwasawa A, Shiota M. Metabolomics analyses of the combined effects of lactic acid bacteria and Penicillium camemberti on the generation of volatile compounds in model mold-surface-ripened cheeses. J Biosci Bioeng 2019; 129:333-347. [PMID: 31611057 DOI: 10.1016/j.jbiosc.2019.09.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 09/03/2019] [Accepted: 09/06/2019] [Indexed: 10/25/2022]
Abstract
The flavor of white mold cheese is attributed to the formation of aroma compounds associated with complex effects of bacteria and fungi, resulting in difficulties in flavor design for new cheeses. This study aimed to identify the microbial basis of flavor by identifying the combined effects of LD type lactic acid bacteria (LAB) starters and Penicillium camemberti on the generation of metabolites during the ripening process. Metabolomics analyses were performed on three model cheeses: normal cheese, no-mold cheese with only LAB, and no-LAB cheese with only white mold. Aroma compounds and their potential precursors were analyzed using headspace solid-phase microextraction-gas chromatography/mass spectrometry (GC/MS) and solvent extraction-GC/MS, respectively. Measurements during ripening and multivariate analyses on the data revealed the relationship between the microorganisms and metabolic activities, which were classified into four groups: metabolites generated by LAB and degraded by P. camemberti; metabolites generated by P. camemberti and degraded or inhibited by LAB; metabolites generated by P. camemberti and enhanced by LAB; and metabolites exhibiting no interaction between P. camemberti and LAB. The characteristic compounds in LAB and white mold cheeses were mainly products of sugar and protein metabolism, respectively. The involvement of fatty acids, methyl ketones, and secondary alcohol metabolic pathways in the late-ripening stage was confirmed, and the profiles of volatile metabolites contributing to the characteristic aroma of the white mold cheese in the fermentation process were also confirmed.
Collapse
Affiliation(s)
- Ai Suzuki-Iwashima
- Milk Science Research Institute, Megmilk Snow Brand Co., Ltd., 1-1-2 Minamidai, Kawagoe, Saitama 350-1165, Japan
| | - Hiroaki Matsuura
- Milk Science Research Institute, Megmilk Snow Brand Co., Ltd., 1-1-2 Minamidai, Kawagoe, Saitama 350-1165, Japan
| | - Ai Iwasawa
- Milk Science Research Institute, Megmilk Snow Brand Co., Ltd., 1-1-2 Minamidai, Kawagoe, Saitama 350-1165, Japan; Central Food Analysis Laboratory, Megmilk Snow Brand Co., Ltd., 1-1-2 Minamidai, Kawagoe, Saitama 350-1165, Japan
| | - Makoto Shiota
- Milk Science Research Institute, Megmilk Snow Brand Co., Ltd., 1-1-2 Minamidai, Kawagoe, Saitama 350-1165, Japan.
| |
Collapse
|
14
|
Sasaki K, Sagawa H, Suzuki M, Yamamoto H, Tomita M, Soga T, Ohashi Y. Metabolomics Platform with Capillary Electrophoresis Coupled with High-Resolution Mass Spectrometry for Plasma Analysis. Anal Chem 2018; 91:1295-1301. [PMID: 30500154 DOI: 10.1021/acs.analchem.8b02994] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Metabolome analysis using capillary electrophoresis (CE) coupled with high-resolution mass spectrometry (HRMS) has the potential to improve coverage of metabolite detection because of its high selectivity and sensitivity. Configuration of the interface between CE and HRMS to meet the ground connection is essential for enabling independent regulation of the electrical currents in the CE and electrospray field. In the present study, we applied an electrospray-ionization adapter equipped with a grounded nebulizer to CE-HRMS and tested the analytical performance for 34 charged compounds. The extracted-ion electropherograms, consisting of seven sets of isomers, showed reasonable peak shapes and separation for the annotation of each metabolite. The levels of 34 target analytes in a standard mixture were determined with a dynamic range of at least 102, maintaining linearity with r2 > 0.9. The repeatability and intermediate precision above the lower limit of quantification showed the relative standard deviation to be lower than 20%. In the spike-recovery experiment, 27 of the 34 metabolites in plasma extract were recovered at a rate of 80 to 120%, suggesting high accuracy. Furthermore, we assessed the feasibility of our platform in metabolome analysis using human-plasma extract. The results showed successful detection of 270 metabolites, indicating the potential of our platform to yield higher coverage of the metabolome. In addition, analysis of dilution integrity demonstrated the quantitative ability of metabolome analysis with CE-HRMS, although the existence of saturation or matrix effects were seen in the case of 33 of the metabolites. This study indicates that our platform has great potential for large-scale metabolome analysis of plasma for biological studies and clinical biomarker screening.
Collapse
Affiliation(s)
- Kazunori Sasaki
- Human Metabolome Technologies Inc. , 246-2 Mizukami , Kakuganji, Tsuruoka , Yamagata 997-0052 , Japan.,Institute for Advanced Biosciences , Keio University , 246-2 Mizukami , Kakuganji, Tsuruoka , Yamagata 997-0052 , Japan
| | - Hitoshi Sagawa
- Human Metabolome Technologies Inc. , 246-2 Mizukami , Kakuganji, Tsuruoka , Yamagata 997-0052 , Japan
| | - Makoto Suzuki
- Human Metabolome Technologies Inc. , 246-2 Mizukami , Kakuganji, Tsuruoka , Yamagata 997-0052 , Japan
| | - Hiroyuki Yamamoto
- Human Metabolome Technologies Inc. , 246-2 Mizukami , Kakuganji, Tsuruoka , Yamagata 997-0052 , Japan
| | - Masaru Tomita
- Institute for Advanced Biosciences , Keio University , 246-2 Mizukami , Kakuganji, Tsuruoka , Yamagata 997-0052 , Japan
| | - Tomoyoshi Soga
- Institute for Advanced Biosciences , Keio University , 246-2 Mizukami , Kakuganji, Tsuruoka , Yamagata 997-0052 , Japan
| | - Yoshiaki Ohashi
- Human Metabolome Technologies Inc. , 246-2 Mizukami , Kakuganji, Tsuruoka , Yamagata 997-0052 , Japan
| |
Collapse
|
15
|
Stolz A, Jooß K, Höcker O, Römer J, Schlecht J, Neusüß C. Recent advances in capillary electrophoresis-mass spectrometry: Instrumentation, methodology and applications. Electrophoresis 2018; 40:79-112. [PMID: 30260009 DOI: 10.1002/elps.201800331] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 09/06/2018] [Accepted: 09/07/2018] [Indexed: 12/14/2022]
Abstract
Capillary electrophoresis (CE) offers fast and high-resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user-friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano-electrospray ionization (ESI), matrix-assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE-MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two-dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE-modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized.
Collapse
Affiliation(s)
| | - Kevin Jooß
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Research Unit Analytical BioGeoChemistry, Helmholtz Zentrum München, Neuherberg, Germany
| | - Oliver Höcker
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Instrumental Analytical Chemistry, University of Duisburg-Essen, Essen, Germany
| | - Jennifer Römer
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Regensburg, Germany
| | - Johannes Schlecht
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Department of Pharmaceutical/Medicinal Chemistry, Friedrich Schiller University, Jena, Germany
| | | |
Collapse
|
16
|
|
17
|
Ramautar R, Somsen GW, de Jong GJ. CE-MS for metabolomics: Developments and applications in the period 2016-2018. Electrophoresis 2018; 40:165-179. [PMID: 30232802 PMCID: PMC6586046 DOI: 10.1002/elps.201800323] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 09/09/2018] [Accepted: 09/10/2018] [Indexed: 12/16/2022]
Abstract
In the field of metabolomics, CE-MS is now recognized as a strong analytical technique for the analysis of (highly) polar and charged metabolites in a wide range of biological samples. Over the past few years, significant attention has been paid to the design and improvement of CE-MS approaches for (large-scale) metabolic profiling studies and for establishing protocols in order to further expand the role of CE-MS in metabolomics. In this paper, which is a follow-up of a previous review paper covering the years 2014-2016 (Electrophoresis 2017, 38, 190-202), main advances in CE-MS approaches for metabolomics studies are outlined covering the literature from July 2016 to June 2018. Aspects like developments in interfacing designs and data analysis tools for improving the performance of CE-MS for metabolomics are discussed. Representative examples highlight the utility of CE-MS in the fields of biomedical, clinical, microbial, and plant metabolomics. A complete overview of recent CE-MS-based metabolomics studies is given in a table, which provides information on sample type and pretreatment, capillary coatings and MS detection mode. Finally, some general conclusions and perspectives are given.
Collapse
Affiliation(s)
- Rawi Ramautar
- Biomedical Microscale Analytics, Leiden Academic Center for Drug Research, Leiden University, Leiden, The Netherlands
| | - Govert W Somsen
- Division of BioAnalytical Chemistry, Amsterdam Institute for Molecules, Medicines and Systems, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Gerhardus J de Jong
- Biomolecular Analysis, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
18
|
Characterization of a nanoflow sheath liquid interface and comparison to a sheath liquid and a sheathless porous-tip interface for CE-ESI-MS in positive and negative ionization. Anal Bioanal Chem 2018; 410:5265-5275. [DOI: 10.1007/s00216-018-1179-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Revised: 05/24/2018] [Accepted: 05/30/2018] [Indexed: 01/22/2023]
|
19
|
Schlecht J, Jooß K, Neusüß C. Two-dimensional capillary electrophoresis-mass spectrometry (CE-CE-MS): coupling MS-interfering capillary electromigration methods with mass spectrometry. Anal Bioanal Chem 2018; 410:6353-6359. [PMID: 29862434 DOI: 10.1007/s00216-018-1157-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Revised: 05/17/2018] [Accepted: 05/23/2018] [Indexed: 11/24/2022]
Abstract
Electromigration separation techniques often demand certain compounds in the electrolyte to achieve the required selectivity and efficiency. These compounds, including the electrolyte itself, ampholytes, polymeric compounds for sieving, complexing agents, tensides, etc. are often non-volatile. Thus, interference with the electrospray ionization process is a common issue, impeding direct coupling of such electrolyte systems to mass spectrometry. Still, several options exist to obtain mass spectra after separation, including offline fractionation, alternative ionization, dilution, or the change to volatile constituents. In the first part of this article, these methods are discussed. However, all of these options are a compromise of separation performance and sensitivity of mass spectrometric detection. Two-dimensional capillary electrophoresis-mass spectrometry (CE-CE-MS) systems represent a promising alternative to the aforementioned challenges, as they allow the use of existing methods with best separation performance in combination with sensitive mass characterization. In this context, the second part of this article is dedicated to the advantages, limitations, and applications of this approach. Finally, an outlook towards future developments is given.
Collapse
Affiliation(s)
- Johannes Schlecht
- Faculty of Chemistry, Aalen University, Beethovenstrasse 1, 73430, Aalen, Germany.,Pharmaceutical/Medicinal Chemistry, Institute of Pharmacy, Friedrich-Schiller-University Jena, Philosophenweg 14, 07743, Jena, Germany
| | - Kevin Jooß
- Faculty of Chemistry, Aalen University, Beethovenstrasse 1, 73430, Aalen, Germany.,Research Unit Analytical BioGeoChemistry, Helmholtz Zentrum München, Ingolstädter Landstr. 1, 85764, Neuherberg, Germany
| | - Christian Neusüß
- Faculty of Chemistry, Aalen University, Beethovenstrasse 1, 73430, Aalen, Germany.
| |
Collapse
|
20
|
|
21
|
González-Ruiz V, Codesido S, Rudaz S, Schappler J. Evolution in the design of a low sheath-flow interface for CE-MS and application to biological samples. Electrophoresis 2017; 39:853-861. [DOI: 10.1002/elps.201700328] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 10/20/2017] [Accepted: 10/21/2017] [Indexed: 12/14/2022]
Affiliation(s)
- Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| | | | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| | - Julie Schappler
- School of Pharmaceutical Sciences, University of Geneva; University of Lausanne; Geneva Switzerland
| |
Collapse
|
22
|
Kašička V. Recent developments in capillary and microchip electroseparations of peptides (2015-mid 2017). Electrophoresis 2017; 39:209-234. [PMID: 28836681 DOI: 10.1002/elps.201700295] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 08/15/2017] [Accepted: 08/16/2017] [Indexed: 12/17/2022]
Abstract
The review brings a comprehensive overview of recent developments and applications of high performance capillary and microchip electroseparation methods (zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography, and electrochromatography) to analysis, microscale isolation, purification, and physicochemical and biochemical characterization of peptides in the years 2015, 2016, and ca. up to the middle of 2017. Advances in the investigation of electromigration properties of peptides and in the methodology of their analysis (sample preseparation, preconcentration and derivatization, adsorption suppression and EOF control, and detection) are described. New developments in particular CE and CEC methods are presented and several types of their applications to peptide analysis are reported: qualitative and quantitative analysis, determination in complex (bio)matrices, monitoring of chemical and enzymatical reactions and physical changes, amino acid, sequence and chiral analysis, and peptide mapping of proteins. Some micropreparative peptide separations are shown and capabilities of CE and CEC methods to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- Václav Kašička
- Institute of Organic Chemistry and Biochemistry, The Czech Academy of Sciences, Prague, Czech Republic
| |
Collapse
|
23
|
Jiang Y, He MY, Zhang WJ, Luo P, Guo D, Fang X, Xu W. Recent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology. CHINESE CHEM LETT 2017. [DOI: 10.1016/j.cclet.2017.05.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
24
|
Dawod M, Arvin NE, Kennedy RT. Recent advances in protein analysis by capillary and microchip electrophoresis. Analyst 2017; 142:1847-1866. [PMID: 28470231 PMCID: PMC5516626 DOI: 10.1039/c7an00198c] [Citation(s) in RCA: 91] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
This review article describes the significant recent advances in the analysis of proteins by capillary and microchip electrophoresis during the period from mid-2014 to early 2017. This review highlights the progressions, new methodologies, innovative instrumental modifications, and challenges for efficient protein analysis in human specimens, animal tissues, and plant samples. The protein analysis fields covered in this review include analysis of native, reduced, and denatured proteins in addition to Western blotting, protein therapeutics and proteomics.
Collapse
Affiliation(s)
- Mohamed Dawod
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, Michigan 48109, USA.
| | | | | |
Collapse
|
25
|
Choi SB, Zamarbide M, Manzini MC, Nemes P. Tapered-Tip Capillary Electrophoresis Nano-Electrospray Ionization Mass Spectrometry for Ultrasensitive Proteomics: the Mouse Cortex. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:597-607. [PMID: 27853976 DOI: 10.1007/s13361-016-1532-8] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Revised: 10/16/2016] [Accepted: 10/18/2016] [Indexed: 06/06/2023]
Abstract
Ultrasensitive characterization of the proteome raises the potential to understand how differential gene expression orchestrates cell heterogeneity in the brain. Here, we report a microanalytical capillary electrophoresis nano-flow electrospray ionization (CE-nanoESI) interface for mass spectrometry to enable the measurement of limited amounts of proteins in the mouse cortex. Our design integrates a custom-built CE system to a tapered-tip metal emitter in a co-axial sheath-flow configuration. This interface can be constructed in <15 min using readily available components, facilitating broad adaptation. Tapered-tip CE-nanoESI generates stable electrospray by reproducibly anchoring the Taylor cone, minimizes sample dilution in the ion source, and ensures efficient ion generation by sustaining the cone-jet spraying regime. Parallel reaction monitoring provided a 260-zmol lower limit of detection for angiotensin II (156,000 copies). CE was able to resolve a complex mixture of peptides in ~330,000 theoretical plates and identify ~15 amol (~1 pg) of BSA or cytochrome c. Over 30 min of separation, 1 ng protein digest from the mouse cortex yielded 217 nonredundant proteins encompassing a ~3-log-order concentration range using a quadrupole time-of-flight mass spectrometer. Identified proteins included many products from genes that are traditionally used to mark oligodendrocytes, astrocytes, and microglia. Finally, key proteins involved in neurodegenerative disorders were detected (e.g., parkinsonism and spastic paraplegia). CE-nanoESI-HRMS delivers sufficient sensitivity to detect proteins in limited amounts of tissues and cell populations to help understand how gene expression differences maintain cell heterogeneity in the brain. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Sam B Choi
- Department of Chemistry, The George Washington University, Washington, DC, 20052, USA
| | - Marta Zamarbide
- Department of Pharmacology and Physiology, The George Washington University, Washington, DC, 20037, USA
| | - M Chiara Manzini
- Department of Pharmacology and Physiology, The George Washington University, Washington, DC, 20037, USA
| | - Peter Nemes
- Department of Chemistry, The George Washington University, Washington, DC, 20052, USA.
| |
Collapse
|
26
|
Next-generation capillary electrophoresis–mass spectrometry approaches in metabolomics. Curr Opin Biotechnol 2017; 43:1-7. [DOI: 10.1016/j.copbio.2016.07.002] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Revised: 06/28/2016] [Accepted: 07/04/2016] [Indexed: 12/14/2022]
|
27
|
Rodrigues KT, Cieslarová Z, Tavares MFM, Simionato AVC. Strategies Involving Mass Spectrometry Combined with Capillary Electrophoresis in Metabolomics. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2017; 965:99-141. [DOI: 10.1007/978-3-319-47656-8_5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
28
|
Ramautar R, Somsen GW, de Jong GJ. CE-MS for metabolomics: Developments and applications in the period 2014-2016. Electrophoresis 2016; 38:190-202. [PMID: 27718257 PMCID: PMC5248609 DOI: 10.1002/elps.201600370] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 09/25/2016] [Accepted: 09/26/2016] [Indexed: 12/11/2022]
Abstract
CE–MS can be considered a useful analytical technique for the global profiling of (highly) polar and charged metabolites in various samples. Over the past few years, significant advancements have been made in CE–MS approaches for metabolomics studies. In this paper, which is a follow‐up of a previous review paper covering the years 2012–2014 (Electrophoresis 2015, 36, 212–224), recent CE–MS strategies developed for metabolomics covering the literature from July 2014 to June 2016 are outlined. Attention will be paid to new CE–MS approaches for the profiling of anionic metabolites and the potential of SPE coupled to CE–MS is also demonstrated. Representative examples illustrate the applicability of CE–MS in the fields of biomedical, clinical, microbial, plant, and food metabolomics. A complete overview of recent CE–MS‐based metabolomics studies is given in a table, which provides information on sample type and pretreatment, capillary coatings, and MS detection mode. Finally, general conclusions and perspectives are given.
Collapse
Affiliation(s)
- Rawi Ramautar
- Division of Analytical Biosciences, LACDR, Leiden University, Leiden, The Netherlands
| | - Govert W Somsen
- Division of BioAnalytical Chemistry, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Gerhardus J de Jong
- Biomolecular Analysis, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
29
|
Týčová A, Ledvina V, Klepárník K. Recent advances in CE-MS coupling: Instrumentation, methodology, and applications. Electrophoresis 2016; 38:115-134. [DOI: 10.1002/elps.201600366] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 08/30/2016] [Accepted: 08/30/2016] [Indexed: 12/17/2022]
Affiliation(s)
- Anna Týčová
- Institute of Analytical Chemistry; Czech Academy of Sciences; Brno Czech Republic
| | - Vojtěch Ledvina
- Institute of Analytical Chemistry; Czech Academy of Sciences; Brno Czech Republic
| | - Karel Klepárník
- Institute of Analytical Chemistry; Czech Academy of Sciences; Brno Czech Republic
| |
Collapse
|
30
|
Yamamoto M, Ly R, Gill B, Zhu Y, Moran-Mirabal J, Britz-McKibbin P. Robust and High-Throughput Method for Anionic Metabolite Profiling: Preventing Polyimide Aminolysis and Capillary Breakages under Alkaline Conditions in Capillary Electrophoresis-Mass Spectrometry. Anal Chem 2016; 88:10710-10719. [DOI: 10.1021/acs.analchem.6b03269] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Mai Yamamoto
- Department of Chemistry and
Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - Ritchie Ly
- Department of Chemistry and
Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - Biban Gill
- Department of Chemistry and
Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - Yujie Zhu
- Department of Chemistry and
Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - Jose Moran-Mirabal
- Department of Chemistry and
Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| | - Philip Britz-McKibbin
- Department of Chemistry and
Chemical Biology, McMaster University, Hamilton, Ontario L8S 4M1, Canada
| |
Collapse
|
31
|
Zhang Y, Ai W, Bai Y, Zhou Y, Wen L, Zhang X, Liu H. An interface for online coupling capillary electrophoresis to dielectric barrier discharge ionization mass spectrometry. Anal Bioanal Chem 2016; 408:8655-8661. [DOI: 10.1007/s00216-016-9822-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Revised: 07/17/2016] [Accepted: 07/21/2016] [Indexed: 12/11/2022]
|
32
|
Štěpánová S, Kašička V. Recent applications of capillary electromigration methods to separation and analysis of proteins. Anal Chim Acta 2016; 933:23-42. [DOI: 10.1016/j.aca.2016.06.006] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 05/10/2016] [Accepted: 06/03/2016] [Indexed: 10/21/2022]
|
33
|
Lombard-Banek C, Reddy S, Moody SA, Nemes P. Label-free Quantification of Proteins in Single Embryonic Cells with Neural Fate in the Cleavage-Stage Frog (Xenopus laevis) Embryo using Capillary Electrophoresis Electrospray Ionization High-Resolution Mass Spectrometry (CE-ESI-HRMS). Mol Cell Proteomics 2016; 15:2756-68. [PMID: 27317400 PMCID: PMC4974349 DOI: 10.1074/mcp.m115.057760] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Revised: 06/16/2016] [Indexed: 12/12/2022] Open
Abstract
Quantification of protein expression in single cells promises to advance a systems-level understanding of normal development. Using a bottom-up proteomic workflow and multiplexing quantification by tandem mass tags, we recently demonstrated relative quantification between single embryonic cells (blastomeres) in the frog (Xenopus laevis) embryo. In this study, we minimize derivatization steps to enhance analytical sensitivity and use label-free quantification (LFQ) for single Xenopus cells. The technology builds on a custom-designed capillary electrophoresis microflow-electrospray ionization high-resolution mass spectrometry platform and LFQ by MaxLFQ (MaxQuant). By judiciously tailoring performance to peptide separation, ionization, and data-dependent acquisition, we demonstrate an ∼75-amol (∼11 nm) lower limit of detection and quantification for proteins in complex cell digests. The platform enabled the identification of 438 nonredundant protein groups by measuring 16 ng of protein digest, or <0.2% of the total protein contained in a blastomere in the 16-cell embryo. LFQ intensity was validated as a quantitative proxy for protein abundance. Correlation analysis was performed to compare protein quantities between the embryo and n = 3 different single D11 blastomeres, which are fated to develop into the nervous system. A total of 335 nonredundant protein groups were quantified in union between the single D11 cells spanning a 4 log-order concentration range. LFQ and correlation analysis detected expected proteomic differences between the whole embryo and blastomeres, and also found translational differences between individual D11 cells. LFQ on single cells raises exciting possibilities to study gene expression in other cells and models to help better understand cell processes on a systems biology level.
Collapse
Affiliation(s)
| | - Sushma Reddy
- From the ‡Department of Chemistry and ¶Thomas Jefferson High School for Science and Technology, Alexandria, Virginia
| | - Sally A Moody
- §Department of Anatomy and Regenerative Biology, The George Washington University, Washington, DC
| | | |
Collapse
|
34
|
A simple sheathless CE-MS interface with a sub-micrometer electrical contact fracture for sensitive analysis of peptide and protein samples. Anal Chim Acta 2016; 936:157-67. [PMID: 27566351 DOI: 10.1016/j.aca.2016.07.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Revised: 06/28/2016] [Accepted: 07/01/2016] [Indexed: 12/11/2022]
Abstract
Online coupling of capillary electrophoresis (CE) to electrospray ionization mass spectrometry (MS) has shown considerable potential, however, technical challenges have limited its use. In this study, we have developed a simple and sensitive sheathless CE-MS interface based on the novel concept of forming a sub-micrometer fracture directly in the capillary. The simple interface design allowed the generation of a stable ESI spray capable of ionization at low nanoliter flow-rates (45-90 nL/min) for high sensitivity MS analysis of challenging samples like those containing proteins and peptides. By analysis of a model peptide (leucine enkephalin), a limit of detection (LOD) of 0.045 pmol/μL (corresponding to 67 attomol in a sample volume of ∼15 nL) was obtained. The merit of the CE-MS approach was demonstrated by analysis of bovine serum albumin (BSA) tryptic peptides. A well-resolved separation profile was achieved and comparable sequence coverage was obtained by the CE-MS method (73%) compared to a representative UPLC-MS method (77%). The CE-MS interface was subsequently used to analyse a more complex sample of pharmaceutically relevant human proteins including insulin, tissue factor and α-synuclein. Efficient separation and protein ESI mass spectra of adequate quality could be achieved using only a small amount of sample (30 fmol). In addition, analysis of ubiquitin samples under both native and denatured conditions, indicate that the CE-MS setup can facilitate native MS applications to probe the conformational properties of proteins. Thus, the described CE-MS setup should be useful for a wide range of high-sensitivity applications in protein research.
Collapse
|
35
|
Abstract
Metabolomics-based strategies have become an integral part of modern clinical research, allowing for a better understanding of pathophysiological conditions and disease mechanisms, as well as providing innovative tools for more adequate diagnostic and prognosis approaches. Metabolomics is considered an essential tool in precision medicine, which aims for personalized prevention and tailor-made treatments. Nevertheless, multiple pitfalls may be encountered in clinical metabolomics during the entire workflow, hampering the quality of the data and, thus, the biological interpretation. This review describes the challenges underlying metabolomics-based experiments, discussing step by step the potential pitfalls of the analytical process, including study design, sample collection, storage, as well as preparation, chromatographic and electrophoretic separation, detection and data analysis. Moreover, it offers practical solutions and strategies to tackle these challenges, ensuring the generation of high-quality data.
Collapse
|
36
|
Recent advances in capillary electrophoretic migration techniques for pharmaceutical analysis (2013-2015). Electrophoresis 2016; 37:1591-608. [DOI: 10.1002/elps.201600058] [Citation(s) in RCA: 82] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Revised: 03/04/2016] [Accepted: 03/04/2016] [Indexed: 11/07/2022]
|
37
|
Gulersonmez MC, Lock S, Hankemeier T, Ramautar R. Sheathless capillary electrophoresis-mass spectrometry for anionic metabolic profiling. Electrophoresis 2016; 37:1007-14. [PMID: 26593113 PMCID: PMC5064653 DOI: 10.1002/elps.201500435] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 11/09/2015] [Accepted: 11/10/2015] [Indexed: 12/23/2022]
Abstract
The performance of CE coupled on-line to MS via a sheathless porous tip sprayer was evaluated for anionic metabolic profiling. A representative metabolite mixture and biological samples were used for the evaluation of various analytical parameters, such as peak efficiency (plate numbers), migration time and peak area repeatability, and LODs. The BGE, i.e. 10% acetic acid (pH 2.2), previously used for cationic metabolic profiling was now assessed for anionic metabolic profiling by using MS detection in negative ion mode. For test compounds, RSDs for migration times and peak areas were below 2 and 11%, respectively, and plate numbers ranged from 60 000 to 40 0000 demonstrating a high separation efficiency. Critical metabolites with low or no retention on reversed-phase LC could be efficiently separated and selectively analyzed by the sheathless CE-MS method. An injection volume of only circa 20 nL resulted in LODs between 10 and 200 nM (corresponding to an amount of 0.4-4 fmol), which was an at least tenfold improvement as compared to LODs obtained by conventional CE-MS approaches for these analytes. The methodology was applied to anionic metabolic profiling of glioblastoma cell line extracts. Overall, a sheathless CE-MS method has been developed for highly efficient and sensitive anionic metabolic profiling studies, which can also be used for cationic metabolic profiling studies by only switching the MS detection and separation voltage polarity.
Collapse
Affiliation(s)
- Mehmet Can Gulersonmez
- Leiden Academic Center for Drug Research, Division of Analytical Biosciences, Leiden University, Leiden, The Netherlands
| | - Stephen Lock
- Sciex, Phoenix House, Center Park, Warrington, UK
| | - Thomas Hankemeier
- Leiden Academic Center for Drug Research, Division of Analytical Biosciences, Leiden University, Leiden, The Netherlands
| | - Rawi Ramautar
- Leiden Academic Center for Drug Research, Division of Analytical Biosciences, Leiden University, Leiden, The Netherlands
| |
Collapse
|
38
|
Wang L, MacDonald D, Huang X, Chen DDY. Capture efficiency of dynamic pH junction focusing in capillary electrophoresis. Electrophoresis 2016; 37:1143-50. [PMID: 26949078 DOI: 10.1002/elps.201600008] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Revised: 02/22/2016] [Accepted: 02/22/2016] [Indexed: 12/17/2022]
Abstract
Dynamic pH junction is one of the techniques used to overcome the issue of poor concentration sensitivity in CE. By introducing a long sample plug in the capillary and focusing the target molecules at the pH boundary between the sample plug and background electrolyte, this focusing technique can achieve a detection limit that is one to two orders of magnitude better than conventional CE. For quantification purposes, the capturing efficiency of the injected molecules should be scrutinized. Focusing of all target molecules inside the sample plug is desired to ensure good linearity across the whole dynamic range. To test the theoretical prediction with a real experiment, nicotine is used as the test molecule for two types of dynamic pH junctions. The first one is with acidic background electrolyte, and can accommodate both optical detection methods and positive-ion mode mass spectrometric detection, while the other is suitable for optical detection only due to the use of basic separation background electrolyte. With a theoretical simulation study, it is demonstrated that, for either of these dynamic pH junctions, focusing of at least 95% of target molecule injected into the capillary was easily achievable. More importantly, a longer sample plug could generate a high percentage of molecules captured by dynamic pH junction focusing. Sharp, symmetrical peaks and good linearity for calibration curve can be obtained. Real samples with complex matrixes were also used to demonstrate that nicotine can be selectively focused and quantified using CE-MS.
Collapse
Affiliation(s)
- Lingyu Wang
- Department of Chemistry, University of British Columbia, Vancouver, BC, Canada
| | - David MacDonald
- Division of Oral and Maxillofacial Radiology, Faculty of Dentistry, University of British Columbia, Vancouver, BC, Canada
| | - Xiaohua Huang
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing P. R., China
| | - David D Y Chen
- Department of Chemistry, University of British Columbia, Vancouver, BC, Canada
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing P. R., China
| |
Collapse
|
39
|
Han M, Rock BM, Pearson JT, Rock DA. Intact mass analysis of monoclonal antibodies by capillary electrophoresis—Mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1011:24-32. [DOI: 10.1016/j.jchromb.2015.12.045] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2015] [Revised: 12/17/2015] [Accepted: 12/20/2015] [Indexed: 12/23/2022]
|
40
|
Abstract
In clinical metabolomics, capillary electrophoresis-mass spectrometry (CE-MS) has become a very useful technique for the analysis of highly polar and charged metabolites in complex biologic samples. A comprehensive overview of recent developments in CE-MS for metabolic profiling studies is presented. This review covers theory, CE separation modes, capillary coatings, and practical aspects of CE-MS coupling. Attention is also given to sample pretreatment and data analysis strategies used for metabolomics. The applicability of CE-MS for clinical metabolomics is illustrated using samples ranging from plasma and urine to cells and tissues. CE-MS application to large-scale and quantitative clinical metabolomics is addressed. Conclusions and perspectives on this unique analytic strategy are presented.
Collapse
|
41
|
Kašička V. Recent developments in capillary and microchip electroseparations of peptides (2013-middle 2015). Electrophoresis 2015; 37:162-88. [DOI: 10.1002/elps.201500329] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2015] [Revised: 08/25/2015] [Accepted: 08/25/2015] [Indexed: 12/16/2022]
Affiliation(s)
- Václav Kašička
- Institute of Organic Chemistry and Biochemistry, v.v.i; The Czech Academy of Sciences; Prague Czech Republic
| |
Collapse
|
42
|
Štěpánová S, Kašička V. Recent developments and applications of capillary and microchip electrophoresis in proteomic and peptidomic analyses. J Sep Sci 2015; 39:198-211. [DOI: 10.1002/jssc.201500973] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2015] [Revised: 10/06/2015] [Accepted: 10/06/2015] [Indexed: 12/19/2022]
Affiliation(s)
- Sille Štěpánová
- Institute of Organic Chemistry and Biochemistry; The Czech Academy of Sciences; Prague Czech Republic
| | - Václav Kašička
- Institute of Organic Chemistry and Biochemistry; The Czech Academy of Sciences; Prague Czech Republic
| |
Collapse
|
43
|
Ramautar R, Somsen GW, de Jong GJ. Developments in coupled solid-phase extraction-capillary electrophoresis 2013-2015. Electrophoresis 2015; 37:35-44. [DOI: 10.1002/elps.201500401] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 10/05/2015] [Accepted: 10/05/2015] [Indexed: 11/08/2022]
Affiliation(s)
- Rawi Ramautar
- Leiden Academic Center for Drug Research; Leiden University; Leiden The Netherlands
| | - Govert W. Somsen
- AIMMS Division of BioAnalytical Chemistry; VU University Amsterdam; Amsterdam The Netherlands
| | | |
Collapse
|
44
|
Wenz C, Barbas C, López-Gonzálvez Á, Garcia A, Benavente F, Sanz-Nebot V, Blanc T, Freckleton G, Britz-McKibbin P, Shanmuganathan M, de l'Escaille F, Far J, Haselberg R, Huang S, Huhn C, Pattky M, Michels D, Mou S, Yang F, Neusuess C, Tromsdorf N, Baidoo EE, Keasling JD, Park SS. Interlaboratory study to evaluate the robustness of capillary electrophoresis-mass spectrometry for peptide mapping. J Sep Sci 2015; 38:3262-3270. [DOI: 10.1002/jssc.201500551] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Revised: 06/19/2015] [Accepted: 06/21/2015] [Indexed: 11/11/2022]
Affiliation(s)
- Christian Wenz
- Agilent Technologies R&D and Marketing GmbH & Co. KG; Waldbronn Germany
| | | | | | | | | | | | - Tim Blanc
- Eli Lilly and Company; Bioanalytical Science; Branchburg NJ USA
| | | | | | | | | | - Johann Far
- University of Liege, Department of Chemistry; Mass Spectrometry Laboratory; Liege Belgium
| | - Rob Haselberg
- VU University Amsterdam; Division of BioAnalytical Chemistry; Amsterdam the Netherlands
- University of Tasmania; School of Chemistry; Hobart Australia
| | | | - Carolin Huhn
- University of Tuebingen; Institute for Physical and Theoretical Chemistry; Tuebingen Germany
| | - Martin Pattky
- University of Tuebingen; Institute for Physical and Theoretical Chemistry; Tuebingen Germany
| | - David Michels
- Genentech, Inc; Protein Analytical Chemistry Department; San Francisco CA USA
| | - Si Mou
- Genentech, Inc; Protein Analytical Chemistry Department; San Francisco CA USA
| | - Feng Yang
- Genentech, Inc; Protein Analytical Chemistry Department; San Francisco CA USA
| | | | | | - Edward E.K. Baidoo
- Joint BioEnergy Institute; Lawrence Berkeley National Laboratory; Emeryville CA USA
| | - Jay D. Keasling
- Joint BioEnergy Institute; Lawrence Berkeley National Laboratory; Emeryville CA USA
| | | |
Collapse
|
45
|
Ciborowski M, Adamska E, Rusak M, Godzien J, Wilk J, Citko A, Bauer W, Gorska M, Kretowski A. CE-MS-based serum fingerprinting to track evolution of type 2 diabetes mellitus. Electrophoresis 2015; 36:2286-2293. [DOI: 10.1002/elps.201500021] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2015] [Revised: 04/15/2015] [Accepted: 04/20/2015] [Indexed: 12/25/2022]
Affiliation(s)
- Michal Ciborowski
- Clinical Research Centre; Medical University of Bialystok; Bialystok Poland
| | - Edyta Adamska
- Clinical Research Centre; Medical University of Bialystok; Bialystok Poland
| | - Magdalena Rusak
- Department of Inorganic and Analytical Chemistry; Medical University of Bialystok; Bialystok Poland
- CEMBIO (Center for Metabolomics and Bioanalysis); Universidad CEU San Pablo; Facultad de Farmacia; Madrid Spain
| | - Joanna Godzien
- CEMBIO (Center for Metabolomics and Bioanalysis); Universidad CEU San Pablo; Facultad de Farmacia; Madrid Spain
| | - Juliusz Wilk
- Clinical Research Centre; Medical University of Bialystok; Bialystok Poland
| | - Anna Citko
- Clinical Research Centre; Medical University of Bialystok; Bialystok Poland
| | - Witold Bauer
- Clinical Research Centre; Medical University of Bialystok; Bialystok Poland
| | - Maria Gorska
- Department of Endocrinology, Diabetology and Internal Medicine; Medical University of Bialystok; Bialystok Poland
| | - Adam Kretowski
- Clinical Research Centre; Medical University of Bialystok; Bialystok Poland
- Department of Endocrinology, Diabetology and Internal Medicine; Medical University of Bialystok; Bialystok Poland
| |
Collapse
|