1
|
Yin B, Zeng Z, Zeng H, Hu H, Zhang M. Open-Source Absorbance Detector with Multiple Deep UV-LEDs for On-Capillary Multiwavelength Detection at a Single Point. Anal Chem 2024; 96:14348-14353. [PMID: 39185905 DOI: 10.1021/acs.analchem.4c03189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/27/2024]
Abstract
On-capillary ultraviolet photometric detection (UV-PD) in a multiwavelength mode provides comprehensive analytical information. However, achieving single-point multiwavelength UV-PD for capillary-scale instruments typically requires high-cost and complex devices. This study presents the development of a cost-effective, open-source absorbance detector for on-capillary multiwavelength detection. The detector employs three deep UV light-emitting diodes emitting at 235, 255, and 278 nm as light sources, each coupled with its own photodetector for independent detection channels. The components are housed using 3D-printed parts, with an Arduino board used for data acquisition. Three individual optical paths, formed by three slits (60 μm width ×1 mm length), surround the measured capillary and converge at the same detection point. The detector demonstrates simultaneous multiwavelength detection of medicines for both HPLC and CE. This development represents an advancement in portable, low-cost analytical instrumentation, with broad implications for various fields of application.
Collapse
Affiliation(s)
- Bangjie Yin
- School of Life and Environmental Sciences, Guangxi Key Laboratory of Automatic Detecting Technology and Instruments, Guilin University of Electronic Technology, Guilin, Guangxi 541004, China
| | - Zihan Zeng
- School of Life and Environmental Sciences, Guangxi Key Laboratory of Automatic Detecting Technology and Instruments, Guilin University of Electronic Technology, Guilin, Guangxi 541004, China
| | - Hui Zeng
- School of Life and Environmental Sciences, Guangxi Key Laboratory of Automatic Detecting Technology and Instruments, Guilin University of Electronic Technology, Guilin, Guangxi 541004, China
| | - Honghua Hu
- Department of Laboratory Medicine and Sichuan Provincial Key Laboratory for Human Disease Gene Study, Sichuan Provincial Peoples Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan 610072, China
| | - Min Zhang
- School of Life and Environmental Sciences, Guangxi Key Laboratory of Automatic Detecting Technology and Instruments, Guilin University of Electronic Technology, Guilin, Guangxi 541004, China
| |
Collapse
|
2
|
Mudugamuwa A, Roshan U, Hettiarachchi S, Cha H, Musharaf H, Kang X, Trinh QT, Xia HM, Nguyen NT, Zhang J. Periodic Flows in Microfluidics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2404685. [PMID: 39246195 DOI: 10.1002/smll.202404685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2024] [Revised: 08/24/2024] [Indexed: 09/10/2024]
Abstract
Microfluidics, the science and technology of manipulating fluids in microscale channels, offers numerous advantages, such as low energy consumption, compact device size, precise control, fast reaction, and enhanced portability. These benefits have led to applications in biomedical assays, disease diagnostics, drug discovery, neuroscience, and so on. Fluid flow within microfluidic channels is typically in the laminar flow region, which is characterized by low Reynolds numbers but brings the challenge of efficient mixing of fluids. Periodic flows are time-dependent fluid flows, featuring repetitive patterns that can significantly improve fluid mixing and extend the effective length of microchannels for submicron and nanoparticle manipulation. Besides, periodic flow is crucial in organ-on-a-chip (OoC) for accurately modeling physiological processes, advancing disease understanding, drug development, and personalized medicine. Various techniques for generating periodic flows have been reported, including syringe pumps, peristalsis, and actuation based on electric, magnetic, acoustic, mechanical, pneumatic, and fluidic forces, yet comprehensive reviews on this topic remain limited. This paper aims to provide a comprehensive review of periodic flows in microfluidics, from fundamental mechanisms to generation techniques and applications. The challenges and future perspectives are also discussed to exploit the potential of periodic flows in microfluidics.
Collapse
Affiliation(s)
- Amith Mudugamuwa
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Uditha Roshan
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Samith Hettiarachchi
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Haotian Cha
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Hafiz Musharaf
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Xiaoyue Kang
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Quang Thang Trinh
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Huan Ming Xia
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Nam-Trung Nguyen
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
| | - Jun Zhang
- Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane, QLD, 4111, Australia
- School of Engineering and Built Environment, Griffith University, Brisbane, QLD, 4111, Australia
| |
Collapse
|
3
|
Abrahamsson V, Henderson BL, Friedman A, Gross J, Prothmann J, Davila AF, Williams AJ, Lin Y, Kanik I, Zhong F. Supercritical CO 2 and Subcritical H 2O Analysis Instrument: Automated Lipid Analysis for In Situ Planetary Life Detection. Anal Chem 2024; 96:13389-13397. [PMID: 39120043 DOI: 10.1021/acs.analchem.4c00474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/10/2024]
Abstract
The search for extraterrestrial extant or extinct life in our Solar System will require highly capable instrumentation and methods for detecting low concentrations of biosignatures. This paper introduces the Supercritical CO2 and Subcritical H2O Analysis (SCHAN) instrument, a portable and automated system that integrates supercritical fluid extraction (SFE), supercritical fluid chromatography (SFC), and subcritical water extraction coupled with liquid chromatography. The instrument is compact and weighs 6.3 kg, making it suitable for spaceflight missions to planetary bodies. Traditional techniques, such as gas chromatography-mass spectrometry (MS), face challenges with involatile and thermally labile analytes, necessitating derivatization. The SCHAN instrument, however, eliminates the need for derivatization and cosolvents by utilizing neat supercritical CO2 with water as an additive. This SFE-SFC-MS method gives efficient lipid biosignature separations with median detection limits of 10 pg/g (ppt) for fatty acids and 50 pg/g (ppt) for sterols. Several free fatty acids and cholesterol were among the detected peaks in biologically lean samples from the Atacama Desert, demonstrating the instrument's potential for in situ life detection missions. The SCHAN instrument addresses the challenges of conventional systems, offering a compact, portable, and spaceflight-compatible tool for the analysis of organics for future astrobiology-focused missions.
Collapse
Affiliation(s)
- Victor Abrahamsson
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena ,California 91109-8001, United States
| | - Bryana L Henderson
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena ,California 91109-8001, United States
| | - Adam Friedman
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena ,California 91109-8001, United States
| | - Johannes Gross
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena ,California 91109-8001, United States
| | - Jens Prothmann
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena ,California 91109-8001, United States
| | - Alfonso F Davila
- NASA Ames Research Center, Moffett Field ,California 94035-1000, United States
| | - Amy J Williams
- University of Florida, Gainesville ,Florida 32611-7011, United States
| | - Ying Lin
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena ,California 91109-8001, United States
| | - Isik Kanik
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena ,California 91109-8001, United States
| | - Fang Zhong
- NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena ,California 91109-8001, United States
| |
Collapse
|
4
|
Cortés-Bautista S, Molins-Legua C, Campíns-Falcó P. Miniaturized liquid chromatography in environmental analysis. A review. J Chromatogr A 2024; 1730:465101. [PMID: 38941795 DOI: 10.1016/j.chroma.2024.465101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 06/14/2024] [Accepted: 06/16/2024] [Indexed: 06/30/2024]
Abstract
The greater and more widespread use of chemicals, either from industry or daily use, is leading to an increase in the discharge of these substances into the environment. Some of these are known to be hazardous to humans and the environment and are regulated, but there is a large and increasing number of substances which pose a potential risk even at low concentration and are not controlled. In this context, new techniques and methodologies are being developed to deal with this concern. Miniaturized liquid chromatography (LC) emerges as a greener and more sensitive alternative to conventional LC. Furthermore, advances in instrument miniaturization have made possible the development of portable LC instrumentation which may become a promising tool for in-situ monitoring. This work reviews the environmental applications of miniaturized LC over the last 15 years and discusses the different instrumentation, including off- and on-line pretreatment techniques, chromatographic conditions, and contributions to the environmental knowledge.
Collapse
Affiliation(s)
- S Cortés-Bautista
- Department Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - C Molins-Legua
- Department Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
| | - P Campíns-Falcó
- Department Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
| |
Collapse
|
5
|
Mai Y, Ghiasvand A, Gupta V, Edwards S, Cahoon S, Debruille K, Mikhail I, Murray E, Paull B. Application of a portable ion chromatograph for real-time field analysis of nitrite and nitrate in soils and soil pore waters. Talanta 2024; 274:126031. [PMID: 38574536 DOI: 10.1016/j.talanta.2024.126031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 03/12/2024] [Accepted: 04/01/2024] [Indexed: 04/06/2024]
Abstract
Real-time monitoring of nitrite and nitrate is crucial for maintaining soil health and promoting plant growth. In this study, a portable ion-chromatograph (IC, Aquamonitrix) analyser, coupled with a field-applicable ultrasonic-assisted extraction method, was utilised for in-field determination of nitrate and nitrite in soils. This is the first application of this type of analyser to soil nutrients. On-site analysis of soil from a local sports field showed 94.8 ± 4.3 μg g-1 nitrate, with LODs of 32.0 μg g-1 for nitrate and 5.4 μg g-1 for nitrite. The results were in close agreement with those obtained using a conventional lab-based IC. Relative standard deviations (%RSDs) for soil analysis using Aquamonitrix were consistently below 10%. The obtained average recoveries of samples spiked with nitrite were 100% and 104% for the portable IC and conventional IC, respectively. Furthermore, to assess the suitability of portable IC for samples with high organic matter content, various natural organic fertilisers were extracted and analysed. The results showed 16.2 ± 0.7 μg g-1 nitrite and 28.5 ± 5.6 μg g-1 nitrate in sheep manure samples with LODs of 2.0 μg g-1 for nitrite and 12.0 μg g-1 for nitrate. The portable IC system was further demonstrated via real-time on-site analysis of soil pore-water acquired using a portable battery-based ceramic pore-water sampler. A continuous increase in nitrate concentration over time was observed (from 80 to 148 μg mL-1) in the soil pore-water in a vegetable garden four days after heavy rain. Unlike conventionally sampled natural waters, 7-day storage of the studied pore water samples revealed no changes in nitrate concentrations. An average of 558 ± 51 μg mL-1 nitrate was detected in the soil pore-water samples analysed on a spinach farm, immediately after irrigation.
Collapse
Affiliation(s)
- Yonglin Mai
- Australian Centre for Research on Separation Science, School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Australia
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science, School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Australia
| | - Vipul Gupta
- Australian Centre for Research on Separation Science, School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Australia
| | | | | | - Kurt Debruille
- Australian Centre for Research on Separation Science, School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Australia
| | - Ibraam Mikhail
- Australian Centre for Research on Separation Science, School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Australia
| | | | - Brett Paull
- Australian Centre for Research on Separation Science, School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Australia.
| |
Collapse
|
6
|
Thu NQ, Tien NTN, Yen NTH, Duong TH, Long NP, Nguyen HT. Push forward LC-MS-based therapeutic drug monitoring and pharmacometabolomics for anti-tuberculosis precision dosing and comprehensive clinical management. J Pharm Anal 2024; 14:16-38. [PMID: 38352944 PMCID: PMC10859566 DOI: 10.1016/j.jpha.2023.09.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 08/25/2023] [Accepted: 09/18/2023] [Indexed: 02/16/2024] Open
Abstract
The spread of tuberculosis (TB), especially multidrug-resistant TB and extensively drug-resistant TB, has strongly motivated the research and development of new anti-TB drugs. New strategies to facilitate drug combinations, including pharmacokinetics-guided dose optimization and toxicology studies of first- and second-line anti-TB drugs have also been introduced and recommended. Liquid chromatography-mass spectrometry (LC-MS) has arguably become the gold standard in the analysis of both endo- and exo-genous compounds. This technique has been applied successfully not only for therapeutic drug monitoring (TDM) but also for pharmacometabolomics analysis. TDM improves the effectiveness of treatment, reduces adverse drug reactions, and the likelihood of drug resistance development in TB patients by determining dosage regimens that produce concentrations within the therapeutic target window. Based on TDM, the dose would be optimized individually to achieve favorable outcomes. Pharmacometabolomics is essential in generating and validating hypotheses regarding the metabolism of anti-TB drugs, aiding in the discovery of potential biomarkers for TB diagnostics, treatment monitoring, and outcome evaluation. This article highlighted the current progresses in TDM of anti-TB drugs based on LC-MS bioassay in the last two decades. Besides, we discussed the advantages and disadvantages of this technique in practical use. The pressing need for non-invasive sampling approaches and stability studies of anti-TB drugs was highlighted. Lastly, we provided perspectives on the prospects of combining LC-MS-based TDM and pharmacometabolomics with other advanced strategies (pharmacometrics, drug and vaccine developments, machine learning/artificial intelligence, among others) to encapsulate in an all-inclusive approach to improve treatment outcomes of TB patients.
Collapse
Affiliation(s)
- Nguyen Quang Thu
- Department of Pharmacology and PharmacoGenomics Research Center, Inje University College of Medicine, Busan, 47392, Republic of Korea
| | - Nguyen Tran Nam Tien
- Department of Pharmacology and PharmacoGenomics Research Center, Inje University College of Medicine, Busan, 47392, Republic of Korea
| | - Nguyen Thi Hai Yen
- Department of Pharmacology and PharmacoGenomics Research Center, Inje University College of Medicine, Busan, 47392, Republic of Korea
| | - Thuc-Huy Duong
- Department of Chemistry, University of Education, Ho Chi Minh City, 700000, Viet Nam
| | - Nguyen Phuoc Long
- Department of Pharmacology and PharmacoGenomics Research Center, Inje University College of Medicine, Busan, 47392, Republic of Korea
| | - Huy Truong Nguyen
- Faculty of Pharmacy, Ton Duc Thang University, Ho Chi Minh City, 700000, Viet Nam
| |
Collapse
|
7
|
Yang Y, Zhou J, Liang Q, Dai X, Yang H, Wan M, Ou J, Liao M, Wang L. Comparing the separation performance of poly(ethyleneimine) embedded butyric and octanoic acid based chromatographic stationary phases. J Chromatogr A 2023; 1706:464268. [PMID: 37544237 DOI: 10.1016/j.chroma.2023.464268] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 07/09/2023] [Accepted: 08/01/2023] [Indexed: 08/08/2023]
Abstract
Poly(ethyleneimine) (PEI) modified silica spheres were used to graft butyric acid and octanoic acid onto their surfaces, forming two stationary phases named Sil-PEI-BAD and Sil-PEI-CAD, respectively. Characterized methods including fourier transform infrared spectroscopy (FT-IR), elemental analysis (EA) and thermogravimetric analysis (TGA) were utilized to determine the successful synthesis of these two stationary phase materials. The chromatographic performance of these two stationary phases was analyzed with hydrophobic and hydrophilic compounds as analytes. Compared with Sil-PEI-CAD column, Sil-PEI-BAD column was more effective in separating hydrophilic compounds including nucleosides, alkaloids and vitamins. Hydrophobic substances including polycyclic aromatic hydrocarbons (PAHs) and alkylbenzenes obtained excellent separation results on Sil-PEI-CAD column than Sil-PEI-BAD column. Additionally, according to the separation of phenols, Sil-PEI-CAD column can be used in HILIC/RPLC mixed-mode. The results showed that the properties and retention mechanisms of the prepared stationary phases depended on the length of the alkyl chains bonded on the silica surface.
Collapse
Affiliation(s)
- Yaxin Yang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Jingqiu Zhou
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Qiaojie Liang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Xuemei Dai
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Honglin Yang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Meijun Wan
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Jing Ou
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Meifang Liao
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China
| | - Lujun Wang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, 646000, China; State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Guangxi Normal University), Guilin, 541004, China; Key Laboratory of Medical Electrophysiology, Ministry of Education, Institute of Cardiovascular Research of Southwest Medical University, Luzhou, Sichuan, 646000, China.
| |
Collapse
|
8
|
Rodríguez-Palma CE, Herráez-Hernández R, Campíns-Falcó P. A modified micro-solid phase extraction device for in-port elution and injection into portable liquid chromatography: A proof-of-concept study. J Chromatogr A 2023; 1705:464216. [PMID: 37480726 DOI: 10.1016/j.chroma.2023.464216] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 07/11/2023] [Accepted: 07/13/2023] [Indexed: 07/24/2023]
Abstract
A micro-solid phase extraction (micro-SPE) device packed with a C18 sorbent (10 mg) has been developed for the enrichment and purification of organic water pollutants prior to their analysis using a portable liquid chromatograph with a dual UV detector. To this end, the sorbent was immobilized at the inlet of a 4 mm syringe filter (0.20 µm), which was modified to reduce its internal volume. The filter was coupled to the needle of the chromatograph. After loading the sample and cleaning the sorbent for analyte purification, the device was installed into the injection port of the chromatograph, and the target compounds were desorbed and transferred directly to the chromatographic column with a small volume of organic solvent. Under optimized conditions, sample volumes as large as 50 mL could be processed with the micro-SPE device, while the analytes were desorbed with only 60 µL of methanol. As a result, efficient preconcentration could be reached, as demonstrated for different water contaminants, namely aclonifen, bifenox, tritosulfuron, triflusulfuron-methyl and caffeine. The proposed micro-SPE device was applied to the analysis of different types of water (river, well, sea, ditch and wastewater). The recoveries of the target compounds in samples ranged from 76 % to 109 %, which allowed their detection at low to sub µg/L levels. All operations were carried out manually, and thus, no additional laboratory instruments such as centrifuges, stirrers or evaporators were required. This proof-of-concept study shows that the proposed micro-SPE approach can be considered a reliable and effective option for the on-site analysis of pollutants in environmental water samples by portable liquid chromatography.
Collapse
Affiliation(s)
- C E Rodríguez-Palma
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| |
Collapse
|
9
|
Liu X, Liang W, Zeng H, Jiang Y, Li Y, Zhang M. 3D printed cartridge for high-speed capillary electrophoresis with sheath liquid thermostatting and contactless conductivity detection. Anal Chim Acta 2023; 1264:341235. [PMID: 37230716 DOI: 10.1016/j.aca.2023.341235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 04/15/2023] [Accepted: 04/18/2023] [Indexed: 05/27/2023]
Abstract
The high-speed capillary electrophoresis (HSCE) method is a technique that utilizes a high electric field strength applied through a short capillary to reduce the time required for sample separation. However, the increased electric field strength may result in pronounced Joule heating effects. To address this, we describe a 3D-printed cartridge with integrated contactless conductivity detection (C4D) head and a sheath liquid channel. The C4D electrodes and Faraday shield layers are fabricated by casting Wood's metal in chambers inside the cartridge. Effective thermostatting of the short capillary is achieved by flowing Fluorinert liquid, which provides better heat dissipation compared to airflow. A HSCE device is created by using the cartridge and a modified slotted-vial array sample-introduction approach. Analytes are introduced through electrokinetic injection. With the help of sheath liquid thermostatting, background electrolyte concentration can be increased to several hundred mM, resulting in improved sample stacking and peak resolutions. Additionally, the baseline signal is flattened. Typical cations such as NH4+, K+, Na+, Mg2+, Li+, and Ca2+ can be separated within 22 s with an applied field strength of 1200 V/cm. The limit of detection ranges from 2.5 to 4.6 μM with a relative standard deviation of migration times of 1.1-1.2% (n = 17). The method has been applied to detect cations in drinking water and black tea leaching for drink safety testing, and to identify explosive anions in paper swabs. Samples can be directly injected without the need for dilution.
Collapse
Affiliation(s)
- Xing Liu
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China
| | - Wenshan Liang
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China
| | - Hui Zeng
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China.
| | - Yiyu Jiang
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China
| | - Yan Li
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China
| | - Min Zhang
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China.
| |
Collapse
|
10
|
Libert BP, Foster SW, Gates EP, Morse M, Ward G, Lee ML, Grinias JP. Exploring Biopharmaceutical Analysis with Compact Capillary Liquid Chromatography Instrumentation. LC GC EUROPE 2023; 36:24-27. [PMID: 37484870 PMCID: PMC10358286 DOI: 10.56530/lcgc.eu.qq7969g7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/25/2023]
Abstract
A recent trend in the design of liquid chromatography (LC) instrumentation is the move towards miniaturized and portable systems. These smaller platforms provide wider flexibility in operation, with the opportunity for conducting analysis directly at the point of sample collection rather than transporting the sample to a centralized laboratory facility. For the manufacturing of pharmaceutical and biopharmaceutical products, these platforms can be implemented for process monitoring and product characterization directly in manufacturing environments. This article describes a portable, miniaturized LC instrument coupled to a mass spectrometer (MS) for characterization of a biopharmaceutical monoclonal antibody (mAb).
Collapse
|
11
|
Closed-loop Control Systems for Pumps used in Portable Analytical Systems. J Chromatogr A 2023; 1695:463931. [PMID: 37011525 DOI: 10.1016/j.chroma.2023.463931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 02/27/2023] [Accepted: 03/14/2023] [Indexed: 03/17/2023]
Abstract
The demand for accurate control of the flowrate/pressure in chemical analytical systems has given rise to the adoption of mechatronic approaches in analytical instruments. A mechatronic device is a synergistic system which combines mechanical, electronic, computer and control components. In the development of portable analytical devices, considering the instrument as a mechatronic system can be useful to mitigate compromises made to decrease space, weight, or power consumption. Fluid handling is important for reliability, however, commonly utilized platforms such as syringe and peristaltic pumps are typically characterized by flow/pressure fluctuations and slow responses. Closed loop control systems have been used effectively to decrease the difference between desired and realized fluidic output. This review discusses the way control systems have been implemented for enhanced fluidic control, categorized by pump type. Advanced control strategies used to enhance the transient and the steady state responses are discussed, along with examples of their implementation in portable analytical systems. The review is concluded with the outlook that the challenge in adequately expressing the complexity and dynamics of the fluidic network as a mathematical model has yielded a trend towards the adoption of experimentally informed models and machine learning approaches.
Collapse
|
12
|
Issaka E, Wariboko MA, Johnson NAN, Aniagyei OND. Advanced visual sensing techniques for on-site detection of pesticide residue in water environments. Heliyon 2023; 9:e13986. [PMID: 36915503 PMCID: PMC10006482 DOI: 10.1016/j.heliyon.2023.e13986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/26/2023] [Accepted: 02/17/2023] [Indexed: 03/02/2023] Open
Abstract
Pesticide usage has increased to fulfil agricultural demand. Pesticides such as organophosphorus pesticides (OPPs) are ubiquitous in world food production. Their widespread usage has unavoidable detrimental consequences for humans, wildlife, water, and soil environments. Hence, the development of more convenient and efficient pesticide residue (PR) detection methods is of paramount importance. Visual detecting approaches have acquired a lot of interest among different sensing systems due to inherent advantages in terms of simplicity, speed, sensitivity, and eco-friendliness. Furthermore, various detections have been proven to enable real-life PR surveillance in environment water. Fluorometric (FL), colourimetric (CL), and enzyme-inhibition (EI) techniques have emerged as viable options. These sensing technologies do not need complex operating processes or specialist equipment, and the simple colour change allows for visual monitoring of the sensing result. Visual sensing techniques for on-site detection of PR in water environments are discussed in this paper. This paper further reviews prior research on the integration of CL, FL, and EI-based techniques with nanoparticles (NPs), quantum dots (QDs), and metal-organic frameworks (MOFs). Smartphone detection technologies for PRs are also reviewed. Finally, conventional methods and nanoparticle (NPs) based strategies for the detection of PRs are compared.
Collapse
Affiliation(s)
- Eliasu Issaka
- School of Environmental Science and Engineering, Jiangsu University, Zhenjiang 212013, PR China
| | - Mary Adumo Wariboko
- School of Medicine, Faculty of Dermatology and Venereology, Jiangsu University, Zhenjiang 212013, PR China
| | | | | |
Collapse
|
13
|
Influence of the Column Inner Diameter on Chromatographic Efficiency in Miniaturized and Conventional Ultra-High-Performance Liquid Chromatography. Chromatographia 2023. [DOI: 10.1007/s10337-023-04237-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
14
|
Mai Y, Debruille K, Edwards S, Cahoon S, Ghiasvand A, Murray E, Paull B. Portable and Field-Deployable Liquid Chromatography for Environmental Studies. LCGC EUROPE 2022. [DOI: 10.56530/lcgc.eu.ux5882h7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
In this extended special feature to celebrate the 35th anniversary edition of LCGC Europe, leading figures from the separation science community explore contemporary trends in separation science and identify possible future developments.
Collapse
|
15
|
An improved design of the fused silica capillary flow cell for absorbance detection in microcolumn liquid chromatography. Anal Chim Acta 2022; 1238:340637. [DOI: 10.1016/j.aca.2022.340637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 11/07/2022] [Accepted: 11/16/2022] [Indexed: 11/19/2022]
|
16
|
Arjun AM, Krishna PH, Nath AR, Rasheed PA. A review on advances in the development of electrochemical sensors for the detection of anesthetic drugs. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:4040-4052. [PMID: 36173296 DOI: 10.1039/d2ay01290a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Surgeries are a crucial medical intervention that has saved countless lives from time immemorial. To reduce pain during surgeries patients are administered with anesthetic drugs, which cause loss of sensation and thus reduce the pain involved. However, anesthetists control the effects of the drug by depending on pharmacokinetic calculations, which may vary from patient to patient, thus leading to a reduction in the quality of anesthetic care and adverse effects. To avoid these adverse effects, it is highly necessary to implement a real time monitoring of plasma drug concentration, which will adjust the drug infusion and maintain the levels of drug within therapeutic levels. To implement such a system, it is highly essential to analyze current advances in electrochemical sensor systems for different types of anesthetic drugs like opioids, intravenous anesthetics, and neuromuscular blockers. This review focuses on the present strategy of electrochemical sensors implemented for the detection of anesthetic drugs and it helps towards developing a real time drug dispensing system with respect to the plasma concentration of the drug. This analysis will contribute towards establishing highly effective real time drug dispensing systems like the total intravenous anesthesia technique and patient-controlled analgesia. Such systems will lead to better usage of anesthetic drugs and improve the quality of anesthetic care thus making surgeries safer and more painless.
Collapse
Affiliation(s)
- Ajith Mohan Arjun
- Department of Biological Sciences and Engineering, Indian Institute of Technology Palakkad, Palakkad, Kerala, India-678 557.
| | - Prasannakumari H Krishna
- Department of Anaesthesiology, Regional Cancer Center, Medical College Campus, Post Bag No. 2417, Thiruvananthapuram, India 695011
| | - Anish R Nath
- DST Unit on Nanoscience and Thematic Unit of Excellence, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India-600036
| | - P Abdul Rasheed
- Department of Biological Sciences and Engineering, Indian Institute of Technology Palakkad, Palakkad, Kerala, India-678 557.
- Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad, Kerala, India-678 557
| |
Collapse
|
17
|
Pursell ME, Sharif D, DeBastiani A, Li C, Majuta S, Li P, Valentine SJ. Development of cVSSI-APCI for the Improvement of Ion Suppression and Matrix Effects in Complex Mixtures. Anal Chem 2022; 94:9226-9233. [PMID: 35729103 PMCID: PMC9260805 DOI: 10.1021/acs.analchem.1c05136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The new ionization technique termed vibrating sharp-edge spray ionization (cVSSI) has been coupled with corona discharge to investigate atmospheric pressure chemical ionization (APCI) capabilities. The optimized source was evaluated for its ability to enhance ion signal intensity, overcome matrix effects, and limit ion suppression. The results have been compared with state-of-the-art ESI source performance as well as a new APCI-like source. In methanol, the ion signal intensity increased 10-fold and >10-fold for cocaine and the suppressed analytes, respectively. The ability to overcome ion suppression was improved from 2-fold to 16-fold for theophylline and vitamin D2, respectively. For aqueous samples, ion signal levels increased by two orders of magnitude for all analytes. In both solvent systems, the signal-to-noise ratios also increased for all suppressed analytes. One example of the characterization of low-ionizing (by ESI or cVSSI alone) species in the presence of high-ionizing species by direct analysis from a cotton swab is presented. The work is discussed with respect to the advantages of cVSSI-APCI for direct, in situ, and field analyses.
Collapse
Affiliation(s)
- Madison E. Pursell
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Daud Sharif
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Anthony DeBastiani
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Sandra Majuta
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| | - Stephen J. Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV 26506
| |
Collapse
|
18
|
Wu M, Zhang Z, Yong J, Schenk PM, Tian D, Xu ZP, Zhang R. Determination and Imaging of Small Biomolecules and Ions Using Ruthenium(II) Complex-Based Chemosensors. Top Curr Chem (Cham) 2022; 380:29. [PMID: 35695976 PMCID: PMC9192387 DOI: 10.1007/s41061-022-00392-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 05/27/2022] [Indexed: 01/13/2023]
Abstract
Luminescence chemosensors are one of the most useful tools for the determination and imaging of small biomolecules and ions in situ in real time. Based on the unique photo-physical/-chemical properties of ruthenium(II) (Ru(II)) complexes, the development of Ru(II) complex-based chemosensors has attracted increasing attention in recent years, and thus many Ru(II) complexes have been designed and synthesized for the detection of ions and small biomolecules in biological and environmental samples. In this work, we summarize the research advances in the development of Ru(II) complex-based chemosensors for the determination of ions and small biomolecules, including anions, metal ions, reactive biomolecules and amino acids, with a particular focus on binding/reaction-based chemosensors for the investigation of intracellular analytes' evolution through luminescence analysis and imaging. The advances, challenges and future research directions in the development of Ru(II) complex-based chemosensors are also discussed.
Collapse
Affiliation(s)
- Miaomiao Wu
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Zexi Zhang
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Jiaxi Yong
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Peer M Schenk
- School of Agriculture and Food Sciences, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Dihua Tian
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Zhi Ping Xu
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, 4072, Australia
| | - Run Zhang
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, QLD, 4072, Australia.
| |
Collapse
|
19
|
Chen A, Liu S. Open Tubular Liquid Chromatographic System for Using Columns with Inner Diameter of 2 µm. A Tutorial. J Chromatogr A 2022; 1673:463202. [DOI: 10.1016/j.chroma.2022.463202] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 05/25/2022] [Accepted: 06/05/2022] [Indexed: 02/01/2023]
|
20
|
Foster SW, Xie X, Hellmig JM, Moura‐Letts G, West WR, Lee ML, Grinias JP. Online monitoring of small volume reactions using compact liquid chromatography instrumentation. SEPARATION SCIENCE PLUS 2022; 5:213-219. [PMID: 37008988 PMCID: PMC10065474 DOI: 10.1002/sscp.202200012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A wide variety of analytical techniques have been employed for monitoring chemical reactions, with online instrumentation providing additional benefits compared to offline analysis. A challenge in the past for online monitoring has been placement of the monitoring instrumentation as close as possible to the reaction vessel to maximize sampling temporal resolution and preserve sample composition integrity. Furthermore, the ability to sample very small volumes from bench-scale reactions allows the use of small reaction vessels and conservation of expensive reagents. In this study, a compact capillary LC instrument was used for online monitoring of as small as 1 mL total volume of a chemical reaction mixture, with automated sampling of nL-scale volumes directly from the reaction vessel used for analysis. Analyses to demonstrate short term (~2 h) and long term (~ 50 h) reactions were conducted using tandem on-capillary ultraviolet absorbance followed by in-line MS detection or ultraviolet absorbance detection alone, respectively. For both short term and long term reactions (10 and 250 injections, respectively), sampling approaches using syringe pumps minimized the overall sample loss to ~0.2% of the total reaction volume.
Collapse
Affiliation(s)
- Samuel W. Foster
- Department of Chemistry & Biochemistry Rowan University Glassboro New Jersey USA
| | - Xiaofeng Xie
- Axcend LLC Provo Utah USA
- Department of Chemistry and Biochemistry Brigham Young University Provo Utah USA
| | - Jacob M. Hellmig
- Department of Chemistry & Biochemistry Rowan University Glassboro New Jersey USA
| | - Gustavo Moura‐Letts
- Department of Chemistry & Biochemistry Rowan University Glassboro New Jersey USA
| | | | - Milton L. Lee
- Axcend LLC Provo Utah USA
- Department of Chemistry and Biochemistry Brigham Young University Provo Utah USA
| | - James P. Grinias
- Department of Chemistry & Biochemistry Rowan University Glassboro New Jersey USA
| |
Collapse
|
21
|
Towards in field miniaturized liquid chromatography: biocides in wastewater as a proof of concept. J Chromatogr A 2022; 1673:463119. [DOI: 10.1016/j.chroma.2022.463119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 04/22/2022] [Accepted: 05/02/2022] [Indexed: 11/18/2022]
|
22
|
Růžička M, Kaljurand M, Gorbatšova J, Vaher M, Mazina-Šinkar J. Portable fully automated oral fluid extraction device for illegal drugs. Talanta 2022; 243:123389. [DOI: 10.1016/j.talanta.2022.123389] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 03/08/2022] [Accepted: 03/11/2022] [Indexed: 11/15/2022]
|
23
|
Tong CY, Derek CJC. A Methodological Review on the Characterization of Microalgal Biofilm and Its Extracellular Polymeric Substances. J Appl Microbiol 2022; 132:3490-3514. [DOI: 10.1111/jam.15455] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 12/21/2021] [Accepted: 01/17/2022] [Indexed: 11/28/2022]
Affiliation(s)
- C. Y. Tong
- School of Chemical Engineering, Engineering Campus Universiti Sains Malaysia 14300 Nibong Tebal, Penang Malaysia
| | - C. J. C Derek
- School of Chemical Engineering, Engineering Campus Universiti Sains Malaysia 14300 Nibong Tebal, Penang Malaysia
| |
Collapse
|
24
|
Ferguson P, Hicks M. The state-of-the-art and future perspectives for SFC. SEP SCI TECHNOL 2022. [DOI: 10.1016/b978-0-323-88487-7.00013-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
25
|
Hemida M, Haddad PR, Lam SC, Coates LJ, Riley F, Diaz A, Gooley AA, Wirth HJ, Guinness S, Sekulic S, Paull B. Small footprint liquid chromatography-mass spectrometry for pharmaceutical reaction monitoring and automated process analysis. J Chromatogr A 2021; 1656:462545. [PMID: 34543882 DOI: 10.1016/j.chroma.2021.462545] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 09/03/2021] [Accepted: 09/04/2021] [Indexed: 12/30/2022]
Abstract
Liquid chromatography (LC) has broad applicability in the pharmaceutical industry, from the early stages of drug discovery to reaction monitoring and process control. However, small footprint, truly portable LC systems have not yet been demonstrated and fully evaluated practically for on-line, in-line or at-line pharmaceutical analysis. Herein, a portable, briefcase-sized capillary LC fitted with a miniature multi-deep UV-LED detector has been developed and interfaced with a portable mass spectrometer for on-site pharmaceutical analysis. With this configuration, the combined small footprint portable LC-UV/MS system was utilized for the determination of small molecule pharmaceuticals and reaction monitoring. The LC-UV/MS system was interfaced directly with a process sample cart and applied to automated pharmaceutical analysis, as well as also being benchmarked against a commercial process UPLC system (Waters PATROL system). The portable system gave low detection limits (∼3 ppb), a wide dynamic range (up to 200 ppm) and was used to confirm the identity of reaction impurities and for studying the kinetics of synthesis. The developed platform showed robust performance for automated process analysis, with less than 5.0% relative standard deviation (RSD) on sample-to-sample reproducibility, and less than 2% carryover between samples. The system has been shown to significantly increase throughput by providing near real-time analysis and to improve understanding of synthetic processes.
Collapse
Affiliation(s)
- Mohamed Hemida
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Paul R Haddad
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Shing C Lam
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Lewellwyn J Coates
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Frank Riley
- Pfizer Worldwide Research and Development, Eastern Point Road, Groton, Connecticut, 06340, United States
| | - Angel Diaz
- Pfizer Worldwide Research and Development, Eastern Point Road, Groton, Connecticut, 06340, United States
| | - Andrew A Gooley
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Hans-Jürgen Wirth
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Steven Guinness
- Pfizer Worldwide Research and Development, Eastern Point Road, Groton, Connecticut, 06340, United States
| | - Sonja Sekulic
- Pfizer Worldwide Research and Development, Eastern Point Road, Groton, Connecticut, 06340, United States
| | - Brett Paull
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.
| |
Collapse
|
26
|
Hemida M, Ghiasvand A, Gupta V, Coates LJ, Gooley AA, Wirth HJ, Haddad PR, Paull B. Small-Footprint, Field-Deployable LC/MS System for On-Site Analysis of Per- and Polyfluoroalkyl Substances in Soil. Anal Chem 2021; 93:12032-12040. [PMID: 34436859 DOI: 10.1021/acs.analchem.1c02193] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Per- and polyfluoroalkyl substances (PFASs) are emerging environmental pollutants of global concern. For rapid field site evaluation, there are very few sensitive, field-deployable analytical techniques. In this work, a portable lightweight capillary liquid chromatography (capLC) system was coupled with a small footprint portable mass spectrometer and configured for field-based applications. Further, an at-site ultrasound-assisted extraction (pUAE) methodology was developed and applied with a portable capLC/mass spectrometry (MS) system for on-site analysis of PFASs in real soil samples. The influential variables on the integration of capLC with MS and on the resolution and signal intensity of the capLC/MS setup were investigated. The important parameters affecting the efficiency of the pUAE method were also studied and optimized using the response surface methodology based on a central composite design. The mean recovery for 11 PFASs ranged between 70 and 110%, with relative standard deviations ranging from 3 to 12%. In-field method sensitivity for 12 PFASs ranged from 0.6 to 0.1 ng/g, with wide dynamic ranges (1-600 ng/g) and excellent linearities (R2 > 0.991). The in-field portable system was benchmarked against a commercial lab-based LC-tandem MS (MS/MS) system for the analysis of PFASs in real soil samples, with the results showing good agreement. When deployed to a field site, 12 PFASs were detected and identified in real soil samples at concentrations ranging from 8.1 ng/g (for perfluorooctanesulfonic acid) to 2935.0 ng/g (perfluorohexanesulfonic acid).
Collapse
Affiliation(s)
- Mohamed Hemida
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Vipul Gupta
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Lewellwyn J Coates
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Andrew A Gooley
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Hans-Jürgen Wirth
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Paul R Haddad
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Brett Paull
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| |
Collapse
|
27
|
Dillon M, Zaczek-Moczydlowska MA, Edwards C, Turner AD, Miller PI, Moore H, McKinney A, Lawton L, Campbell K. Current Trends and Challenges for Rapid SMART Diagnostics at Point-of-Site Testing for Marine Toxins. SENSORS (BASEL, SWITZERLAND) 2021; 21:2499. [PMID: 33916687 PMCID: PMC8038394 DOI: 10.3390/s21072499] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/21/2021] [Accepted: 03/24/2021] [Indexed: 12/26/2022]
Abstract
In the past twenty years marine biotoxin analysis in routine regulatory monitoring has advanced significantly in Europe (EU) and other regions from the use of the mouse bioassay (MBA) towards the high-end analytical techniques such as high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS). Previously, acceptance of these advanced methods, in progressing away from the MBA, was hindered by a lack of commercial certified analytical standards for method development and validation. This has now been addressed whereby the availability of a wide range of analytical standards from several companies in the EU, North America and Asia has enhanced the development and validation of methods to the required regulatory standards. However, the cost of the high-end analytical equipment, lengthy procedures and the need for qualified personnel to perform analysis can still be a challenge for routine monitoring laboratories. In developing regions, aquaculture production is increasing and alternative inexpensive Sensitive, Measurable, Accurate and Real-Time (SMART) rapid point-of-site testing (POST) methods suitable for novice end users that can be validated and internationally accepted remain an objective for both regulators and the industry. The range of commercial testing kits on the market for marine toxin analysis remains limited and even more so those meeting the requirements for use in regulatory control. Individual assays include enzyme-linked immunosorbent assays (ELISA) and lateral flow membrane-based immunoassays (LFIA) for EU-regulated toxins, such as okadaic acid (OA) and dinophysistoxins (DTXs), saxitoxin (STX) and its analogues and domoic acid (DA) in the form of three separate tests offering varying costs and benefits for the industry. It can be observed from the literature that not only are developments and improvements ongoing for these assays, but there are also novel assays being developed using upcoming state-of-the-art biosensor technology. This review focuses on both currently available methods and recent advances in innovative methods for marine biotoxin testing and the end-user practicalities that need to be observed. Furthermore, it highlights trends that are influencing assay developments such as multiplexing capabilities and rapid POST, indicating potential detection methods that will shape the future market.
Collapse
Affiliation(s)
- Michael Dillon
- Institute for Global Food Security, School of Biological Sciences, Queen’s University Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, UK; (M.D.); (M.A.Z.-M.)
- Faculty of Health, Peninsula Medical School, University of Plymouth, Plymouth PL4 8AA, UK
| | - Maja A. Zaczek-Moczydlowska
- Institute for Global Food Security, School of Biological Sciences, Queen’s University Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, UK; (M.D.); (M.A.Z.-M.)
| | - Christine Edwards
- School of Pharmacy and Life Sciences, Robert Gordon University, Aberdeen AB10 7GJ, UK; (C.E.); (L.L.)
| | - Andrew D. Turner
- Centre for Environment, Fisheries and Aquaculture Science, The Nothe, Barrack Road, Weymouth, Dorset DT4 8UB, UK;
| | - Peter I. Miller
- Plymouth Marine Laboratory, Remote Sensing Group, Prospect Place, Plymouth PL1 3DH, UK;
| | - Heather Moore
- Agri-Food and Biosciences Institute, 18a Newforge Lane, Belfast, Northern Ireland BT9 5PX, UK; (H.M.); (A.M.)
| | - April McKinney
- Agri-Food and Biosciences Institute, 18a Newforge Lane, Belfast, Northern Ireland BT9 5PX, UK; (H.M.); (A.M.)
| | - Linda Lawton
- School of Pharmacy and Life Sciences, Robert Gordon University, Aberdeen AB10 7GJ, UK; (C.E.); (L.L.)
| | - Katrina Campbell
- Institute for Global Food Security, School of Biological Sciences, Queen’s University Belfast, 19 Chlorine Gardens, Belfast BT9 5DL, UK; (M.D.); (M.A.Z.-M.)
| |
Collapse
|
28
|
Chatzimichail S, Rahimi F, Saifuddin A, Surman AJ, Taylor-Robinson SD, Salehi-Reyhani A. Hand-portable HPLC with broadband spectral detection enables analysis of complex polycyclic aromatic hydrocarbon mixtures. Commun Chem 2021; 4:17. [PMID: 36697529 PMCID: PMC9814556 DOI: 10.1038/s42004-021-00457-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 01/19/2021] [Indexed: 01/28/2023] Open
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are considered priority hazardous substances due to their carcinogenic activity and risk to public health. Strict regulations are in place limiting their release into the environment, but enforcement is hampered by a lack of adequate field-testing procedure, instead relying on sending samples to centralised analytical facilities. Reliably monitoring levels of PAHs in the field is a challenge, owing to the lack of field-deployable analytical methods able to separate, identify, and quantify the complex mixtures in which PAHs are typically observed. Here, we report the development of a hand-portable system based on high-performance liquid chromatography incorporating a spectrally wide absorption detector, capable of fingerprinting PAHs based on their characteristic spectral absorption profiles: identifying 100% of the 24 PAHs tested, including full coverage of the United States Environmental Protection Agency priority pollutant list. We report unsupervised methods to exploit these new capabilities for feature detection and identification, robust enough to detect and classify co-eluting and hidden peaks. Identification is fully independent of their characteristic retention times, mitigating matrix effects which can preclude reliable determination of these analytes in challenging samples. We anticipate the platform to enable more sophisticated analytical measurements, supporting real-time decision making in the field.
Collapse
Affiliation(s)
| | - Faraz Rahimi
- Department of Surgery and Cancer, Imperial College London, London, W12 0HS, UK
- Department of Chemistry, King's College London, London, SE1 1DB, UK
| | - Aliyah Saifuddin
- Department of Surgery and Cancer, Imperial College London, London, W12 0HS, UK
- Department of Chemistry, King's College London, London, SE1 1DB, UK
| | - Andrew J Surman
- Department of Chemistry, King's College London, London, SE1 1DB, UK
| | | | - Ali Salehi-Reyhani
- Department of Surgery and Cancer, Imperial College London, London, W12 0HS, UK.
- Institute of Molecular Sciences & Engineering, Imperial College London, London, SW7 2AZ, UK.
| |
Collapse
|
29
|
Davis JJ, Foster SW, Grinias JP. Low-cost and open-source strategies for chemical separations. J Chromatogr A 2021; 1638:461820. [PMID: 33453654 PMCID: PMC7870555 DOI: 10.1016/j.chroma.2020.461820] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/12/2020] [Accepted: 12/14/2020] [Indexed: 12/18/2022]
Abstract
In recent years, a trend toward utilizing open access resources for laboratory research has begun. Open-source design strategies for scientific hardware rely upon the use of widely available parts, especially those that can be directly printed using additive manufacturing techniques and electronic components that can be connected to low-cost microcontrollers. Open-source software eliminates the need for expensive commercial licenses and provides the opportunity to design programs for specific needs. In this review, the impact of the "open-source movement" within the field of chemical separations is described, primarily through a comprehensive look at research in this area over the past five years. Topics that are covered include general laboratory equipment, sample preparation techniques, separations-based analysis, detection strategies, electronic system control, and software for data processing. Remaining hurdles and possible opportunities for further adoption of open-source approaches in the context of these separations-related topics are also discussed.
Collapse
Affiliation(s)
- Joshua J Davis
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States
| | - Samuel W Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States
| | - James P Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States.
| |
Collapse
|
30
|
Lankelma J, van Iperen DJ, van der Sluis PJ. Towards using high-performance liquid chromatography at home. J Chromatogr A 2021; 1639:461925. [PMID: 33556779 DOI: 10.1016/j.chroma.2021.461925] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 01/13/2021] [Accepted: 01/16/2021] [Indexed: 12/26/2022]
Abstract
In order to make high-performance liquid chromatography (HPLC) more widely available at home and in small-scale settings, we have simplified two of its most costly modules, namely the pump and the detector. This should make the setup affordable for home or small laboratory use. A manual HPLC pump was constructed so as to fit into a caulk gun from a local hardware store enabling the generation of 100-150 bar of pressure. In order to limit the pressure drop during the running of a chromatogram, a pulse dampener was developed. We further modified the electrochemical detection (ECD) system so as to use a cheap boron-doped diamond electrode with an overlay of thin filter paper, causing an eluent flow over the electrode by wicking and gravity. Both the pump and the detector are at least ten times cheaper than conventional HPLC modules. Using a home-packed JupiterⓇ Proteo reversed phase capillary column we show how this low-cost HPLC system generates well resolving chromatograms after direct injection of fresh urine. The ECD did not lose its sensitivity during regular use over more than half a year. For homovanillic acid (HVA), which is of medical interest, we measured a linear dynamic range of two orders of magnitude, a detection limit of HVA in the injected sample of 3 μM and a coefficient of variation <10%. The contribution to peak broadening by the detector was much smaller than the contributions by the injector and by the column. After consumption of table olives containing hydroxytyrosol (HT), its metabolite HVA in the corresponding urine could be measured quantitatively. An approach to quantify HT in table olives is presented, as well. This method provides a new tool for investigating physiology of oneself or of dear ones at home.
Collapse
Affiliation(s)
- Jan Lankelma
- Department of Molecular Cell Physiology, VU University Amsterdam, O
- 2 Lab Building, De Boelelaan 1108, 1081 HZ Amsterdam, The Netherlands; Foundation for Chromatography at home, Demonstrator Lab, Amsterdam, The Netherlands.
| | - Dirck J van Iperen
- Department of Fine mechanics and Engineering VU - Bèta, VU University Amsterdam, The Netherlands
| | - Paul J van der Sluis
- Foundation for Chromatography at home, Demonstrator Lab, Amsterdam, The Netherlands
| |
Collapse
|
31
|
Advances in the Detection of Dithiocarbamate Fungicides: Opportunities for Biosensors. BIOSENSORS-BASEL 2020; 11:bios11010012. [PMID: 33396914 PMCID: PMC7824625 DOI: 10.3390/bios11010012] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 12/24/2020] [Accepted: 12/27/2020] [Indexed: 12/21/2022]
Abstract
Dithiocarbamate fungicides (DTFs) are widely used to control various fungal diseases in crops and ornamental plants. Maximum residual limits in the order of ppb-ppm are currently imposed by legislation to prevent toxicity problems associated with excessive use of DTFs. The specific analytical determination of DTFs is complicated by their low solubility in water and organic solvents. This review summarizes the current analytical procedures used for the analysis of DTF, including chromatography, spectroscopy, and sensor-based methods and discusses the challenges related to selectivity, sensitivity, and sample preparation. Biosensors based on enzymatic inhibition demonstrated potential as analytical tools for DTFs and warrant further research, considering novel enzymes from extremophilic sources. Meanwhile, Raman spectroscopy and various sensors appear very promising, provided the selectivity issues are solved.
Collapse
|