1
|
Govindarajan V, Kolanjiyil A, Johnson NP, Kim H, Chandran KB, McPherson DD. Improving transcatheter aortic valve interventional predictability via fluid-structure interaction modelling using patient-specific anatomy. ROYAL SOCIETY OPEN SCIENCE 2022; 9:211694. [PMID: 35154799 PMCID: PMC8826300 DOI: 10.1098/rsos.211694] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 01/04/2022] [Indexed: 05/03/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) is now a standard treatment for high-surgical-risk patients with severe aortic valve stenosis. TAVR is being explored for broader indications including degenerated bioprosthetic valves, bicuspid valves and for aortic valve (AV) insufficiency. It is, however, challenging to predict whether the chosen valve size, design or its orientation would produce the most-optimal haemodynamics in the patient. Here, we present a novel patient-specific evaluation framework to realistically predict the patient's AV performance with a high-fidelity fluid-structure interaction analysis that included the patient's left ventricle and ascending aorta (AAo). We retrospectively evaluated the pre- and post-TAVR dynamics of a patient who underwent a 23 mm TAVR and evaluated against the patient's virtually de-calcified AV serving as a hypothetical benchmark. Our model predictions were consistent with clinical data. Stenosed AV produced a turbulent flow during peak-systole, while aortic flow with TAVR and de-calcified AV were both in the laminar-to-turbulent transitional regime with an estimated fivefold reduction in viscous dissipation. For TAVR, dissipation was highest during early systole when valve deformation was the greatest, suggesting that an efficient valve opening may reduce energy loss. Our study demonstrates that such patient-specific modelling frameworks can be used to improve predictability and in the planning of AV interventions.
Collapse
Affiliation(s)
- Vijay Govindarajan
- Division of Cardiology, Department of Internal Medicine, McGovern Medical School, The University of Texas Health Science at Houston, 1881 East Road, Houston, TX 77054, USA
| | - Arun Kolanjiyil
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Nils P. Johnson
- Division of Cardiology, Department of Internal Medicine, McGovern Medical School, The University of Texas Health Science at Houston, 1881 East Road, Houston, TX 77054, USA
| | - Hyunggun Kim
- Division of Cardiology, Department of Internal Medicine, McGovern Medical School, The University of Texas Health Science at Houston, 1881 East Road, Houston, TX 77054, USA
- Department of Bio-Mechatronic Engineering, Sungkyunkwan University, Suwon, Gyeonggi, Korea
| | - Krishnan B. Chandran
- Division of Cardiology, Department of Internal Medicine, McGovern Medical School, The University of Texas Health Science at Houston, 1881 East Road, Houston, TX 77054, USA
- Roy J. Carver Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA
| | - David D. McPherson
- Division of Cardiology, Department of Internal Medicine, McGovern Medical School, The University of Texas Health Science at Houston, 1881 East Road, Houston, TX 77054, USA
| |
Collapse
|
2
|
Goode D, Dhaliwal R, Mohammadi H. Transcatheter Mitral Valve Replacement: State of the Art. Cardiovasc Eng Technol 2020; 11:229-253. [DOI: 10.1007/s13239-020-00460-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 02/14/2020] [Indexed: 10/24/2022]
|
3
|
Obidowski D, Reorowicz P, Witkowski D, Sobczak K, Jóźwik K. Methods for determination of stagnation in pneumatic ventricular assist devices. Int J Artif Organs 2018; 41:653-663. [PMID: 30073903 PMCID: PMC6159782 DOI: 10.1177/0391398818790204] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
Abstract
Background: A pneumatic paediatric ventricular assist device developed at the Foundation of Cardiac Surgery Development, Zabrze, equipped with valves based on J. Moll’s design, with later modifications introduced at the Institute of Turbomachinery, Lodz University of Technology, was tested numerically and experimentally. The main aim of those investigations was to detect stagnation zones within the ventricular assist device and indicate advantages and limitations of both approaches. Methods: In the numerical transient test, a motion of the diaphragm and discs was simulated. Two different methods were used to illustrate stagnation zones in the ventricular assist device. The flow pattern inside the chamber was represented by velocity contours and vectors to validate the results using images obtained in the laser particle image velocimetry experiment. Results: The experimental light-based method implied problems with proper illumination of regions in the wall vicinity. High-resolution flow data and other important parameters as stagnation regions or flow patterns in regions not accessible for light in the particle image velocimetry method are derived in the numerical solution. However, computations of a single case are much more time-consuming if compared to a single experiment conducted on a well-calibrated stand. Conclusion: The resulting main vortexes in the central part of the pump chamber and the velocity magnitudes are correlated in both methods, which are complementary and when used together offer better insight into the flow structure inside the ventricular assist device and enable a deeper analysis of the results.
Collapse
Affiliation(s)
- Damian Obidowski
- Division of Medical Apparatus, Institute of Turbomachinery, Lodz University of Technology, Lodz, Poland
| | - Piotr Reorowicz
- Division of Medical Apparatus, Institute of Turbomachinery, Lodz University of Technology, Lodz, Poland
| | - Dariusz Witkowski
- Division of Medical Apparatus, Institute of Turbomachinery, Lodz University of Technology, Lodz, Poland
| | - Krzysztof Sobczak
- Division of Medical Apparatus, Institute of Turbomachinery, Lodz University of Technology, Lodz, Poland
| | - Krzysztof Jóźwik
- Division of Medical Apparatus, Institute of Turbomachinery, Lodz University of Technology, Lodz, Poland
| |
Collapse
|
4
|
Govindarajan V, Mousel J, Udaykumar HS, Vigmostad SC, McPherson DD, Kim H, Chandran KB. Synergy between Diastolic Mitral Valve Function and Left Ventricular Flow Aids in Valve Closure and Blood Transport during Systole. Sci Rep 2018; 8:6187. [PMID: 29670148 PMCID: PMC5906696 DOI: 10.1038/s41598-018-24469-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 03/27/2018] [Indexed: 11/30/2022] Open
Abstract
Highly resolved three-dimensional (3D) fluid structure interaction (FSI) simulation using patient-specific echocardiographic data can be a powerful tool for accurately and thoroughly elucidating the biomechanics of mitral valve (MV) function and left ventricular (LV) fluid dynamics. We developed and validated a strongly coupled FSI algorithm to fully characterize the LV flow field during diastolic MV opening under physiologic conditions. Our model revealed that distinct MV deformation and LV flow patterns developed during different diastolic stages. A vortex ring that strongly depended on MV deformation formed during early diastole. At peak E wave, the MV fully opened, with a local Reynolds number of ~5500, indicating that the flow was in the laminar-turbulent transitional regime. Our results showed that during diastasis, the vortex structures caused the MV leaflets to converge, thus increasing mitral jet’s velocity. The vortex ring became asymmetrical, with the vortex structures on the anterior side being larger than on the posterior side. During the late diastolic stages, the flow structures advected toward the LV outflow tract, enhancing fluid transport to the aorta. This 3D-FSI study demonstrated the importance of leaflet dynamics, their effect on the vortex ring, and their influence on MV function and fluid transport within the LV during diastole.
Collapse
Affiliation(s)
- Vijay Govindarajan
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA.,Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas McGovern Medical School, Houston, TX, USA
| | - John Mousel
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA
| | - H S Udaykumar
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA
| | - Sarah C Vigmostad
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA
| | - David D McPherson
- Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas McGovern Medical School, Houston, TX, USA
| | - Hyunggun Kim
- Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas McGovern Medical School, Houston, TX, USA. .,Department of Biomechatronic Engineering, Sungkyunkwan University, Suwon, Gyeonggi, Korea.
| | - Krishnan B Chandran
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA.
| |
Collapse
|
5
|
Majumdar S, Patil CN, Ladner-Threadgill T, Randolph E, Burgreen GW, Kermode JC. Platelet activation and erythrocyte lysis during brief exposure of blood to pathophysiological shear stress in vitro. Clin Hemorheol Microcirc 2018; 67:159-172. [PMID: 28800323 DOI: 10.3233/ch-170256] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Interaction of von Willebrand factor (VWF) with circulating platelets is the trigger for thrombosis in a region of arterial stenosis. These events are typically studied in vitro under conditions where platelets adhere to a VWF-coated surface. Our approach assesses platelet responses in the absence of adhesion. OBJECTIVE To characterize extent of platelet activation and erythrocyte lysis in an artificial stenosis model. METHODS Whole blood is perfused through a length of polyetheretherketone tubing that includes an artificial stenosis, comprising narrow-bore (89-381 μm) tubing. Secretion of [14C] serotonin and hemoglobin release was measured to evaluate platelet activation and hemolysis respectively at various perfusion rates and different stenosis dimensions. RESULTS Platelet activation and erythrocyte lysis increased progressively with increasing perfusion rate and decreasing stenosis diameter; the length of the stenosis had negligible influence. Modest platelet activation (5-10% secretion of [14C] serotonin) occurred without significant erythrocyte lysis under a limited range of perfusion conditions (4-6 mL/min flow through a 127 μm stenosis). CONCLUSIONS Our experimental approach mimics conditions in severe arterial stenosis or a mechanical heart valve. It could be a valuable aid in the development of novel drugs to treat arterial thrombosis and in the design of heart valves.
Collapse
Affiliation(s)
- Suvankar Majumdar
- Department of Pediatrics, Children's National Medical Center, Washington, DC, USA.,Department of Pediatrics, University of Mississippi Medical Center, Jackson, MS, USA
| | - Chetan N Patil
- Department of Biochemistry, University of Mississippi Medical Center, Jackson, MS, USA
| | | | - Erica Randolph
- Department of Biology, Tougaloo College, Tougaloo, MS, USA
| | - Greg W Burgreen
- ERC-SimCenter, Mississippi State University, Starkville, MS, USA
| | - John C Kermode
- Department of Pediatrics, University of Mississippi Medical Center, Jackson, MS, USA
| |
Collapse
|
6
|
Review of numerical methods for simulation of mechanical heart valves and the potential for blood clotting. Med Biol Eng Comput 2017; 55:1519-1548. [DOI: 10.1007/s11517-017-1688-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 07/10/2017] [Indexed: 11/26/2022]
|
7
|
Scotten LN, Siegel R. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models. ANNALS OF TRANSLATIONAL MEDICINE 2015; 3:197. [PMID: 26417581 DOI: 10.3978/j.issn.2305-5839.2015.08.18] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
BACKGROUND Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. METHODS Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. RESULTS Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). CONCLUSIONS Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring the anti-coagulation independent mechanical valve within reach.
Collapse
Affiliation(s)
- Lawrence N Scotten
- 1 ViVitro Systems Inc. (VSI), Victoria, BC, Canada ; 2 Lake Oswego, OR, USA
| | - Rolland Siegel
- 1 ViVitro Systems Inc. (VSI), Victoria, BC, Canada ; 2 Lake Oswego, OR, USA
| |
Collapse
|
8
|
Lagrangian postprocessing of computational hemodynamics. Ann Biomed Eng 2014; 43:41-58. [PMID: 25059889 DOI: 10.1007/s10439-014-1070-0] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2014] [Accepted: 07/11/2014] [Indexed: 10/25/2022]
Abstract
Recent advances in imaging, modeling, and computing have rapidly expanded our capabilities to model hemodynamics in the large vessels (heart, arteries, and veins). This data encodes a wealth of information that is often under-utilized. Modeling (and measuring) blood flow in the large vessels typically amounts to solving for the time-varying velocity field in a region of interest. Flow in the heart and larger arteries is often complex, and velocity field data provides a starting point for investigating the hemodynamics. This data can be used to perform Lagrangian particle tracking, and other Lagrangian-based postprocessing. As described herein, Lagrangian methods are necessary to understand inherently transient hemodynamic conditions from the fluid mechanics perspective, and to properly understand the biomechanical factors that lead to acute and gradual changes of vascular function and health. The goal of the present paper is to review Lagrangian methods that have been used in post-processing velocity data of cardiovascular flows.
Collapse
|
9
|
Bahraseman HG, Hassani K, Khosravi A, Navidbakhsh M, Espino DM, Fatouraee N, Kazemi-Saleh D. Combining numerical and clinical methods to assess aortic valve hemodynamics during exercise. Perfusion 2014; 29:340-350. [DOI: 10.1177/0267659114521103] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Computational simulations have the potential to aid understanding of cardiovascular hemodynamics under physiological conditions, including exercise. Therefore, blood hemodynamic parameters during different heart rates, rest and exercise have been investigated, using a numerical method. A model was developed for a healthy subject. Using geometrical data acquired by echo-Doppler, a two-dimensional model of the chamber of aortic sinus valsalva and aortic root was created. Systolic ventricular and aortic pressures were applied as boundary conditions computationally. These pressures were the initial physical conditions applied to the model to predict valve deformation and changes in hemodynamics. They were the clinically measured brachial pressures plus differences between brachial, central and left ventricular pressures. Echocardiographic imaging was also used to acquire different ejection times, necessary for pressure waveform equations of blood flow during exercise. A fluid-structure interaction simulation was performed, using an arbitrary Lagrangian-Eulerian mesh. During exercise, peak vorticity increased by 14.8%, peak shear rate by 15.8%, peak cell Reynolds number by 20%, peak leaflet tip velocity increased by 47% and the blood velocity increased by 3% through the leaflets, whereas full opening time decreased by 11%. Our results show that numerical methods can be combined with clinical measurements to provide good estimates of patient-specific hemodynamics at different heart rates.
Collapse
Affiliation(s)
- HG Bahraseman
- Department of Biomechanics, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - K Hassani
- Department of Biomechanics, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - A Khosravi
- Atherosclerosis Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - M Navidbakhsh
- Department of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - DM Espino
- School of Mechanical Engineering, University of Birmingham, UK
| | - N Fatouraee
- Department of Biomedical Engineering, Amirkabir University, Tehran, Iran
| | - D Kazemi-Saleh
- Atherosclerosis Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran
| |
Collapse
|
10
|
Abstract
About 1-2 % of the babies are born with bicuspid aortic valves instead of the normal aortic valve with three leaflets. A significant portion of the patients with the congenital bicuspid valve morphology suffer from aortic valve stenosis and/or ascending aortic dilatation and dissection thus requiring surgical intervention when they are young adults. Patients with bicuspid aortic valves (BAVs) have also been found to develop valvular stenosis earlier than those with the normal aortic valve. This paper overviews current knowledge of BAVs, where several studies have suggested that the mechanical stresses induced on the valve leaflets and the abnormal flow development in the ascending aorta may be an important factor in the diseases of the valve and the aortic root. The long-term goals of the studies being performed in our laboratory are aimed towards potential stratification of bicuspid valve patients who may be at risk for developing these pathologies based on analyzing the hemodynamic environment of these valves using fluid-structure interaction (FSI) modeling. Patient-specific geometry of the normal tri-cuspid and bicuspid valves are reconstructed from real-time 3D ultrasound images and the dynamic analyses performed in order to determine the potential effects of mechanical stresses on the valve leaflet and aortic root pathology. This paper describes the details of the computational tools and discusses challenges with patient-specific modeling.
Collapse
Affiliation(s)
- Krishnan B Chandran
- Department of Biomedical Engineering and IIHR-Hydroscience and Engineering, College of Engineering, University of Iowa, Iowa City, IA 52242, USA
| | | |
Collapse
|
11
|
Ertan Taskin M, Zhang T, Fraser KH, Griffith BP, Wu ZJ. Design Optimization of a Wearable Artificial Pump-Lung Device With Computational Modeling. J Med Device 2012. [DOI: 10.1115/1.4007282] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
The heart-lung machine has commonly been used to replace the functions of both the heart and lungs during open heart surgeries or implemented as extracorporeal membrane oxygenation (ECMO) to provide cardiopulmonary support of the heart and lungs. The traditional heart-lung system consists of multiple components and is bulky. It can only be used for relatively short-term support. The concept of the wearable artificial pump-lung is to combine the functions of the blood pumping and gas transfer in a single, compact unit for cardiopulmonary or respiratory support for patients suffering from cardiac failure or respiratory failure, or both, and to allow patients to be ambulatory. To this end, a wearable artificial lung (APL) device is being developed by integrating a magnetically levitated centrifugal impeller with a hollow fiber membrane bundle. In this study, we utilized a computational fluid dynamics based performance optimization with a heuristic scheme to derive geometrical design parameters for the wearable APL device. The configuration and dimensions of the impeller and the diffuser, the required surface area of fiber membranes and the overall geometrical dimensions of the blood flow path of the APL device were considered. The design optimization was iterated based on the fluid dynamic objective parameters (pressure head, pressure distribution, axial force acting on the impeller, shear stress), blood damage potential (hemolysis and platelet activation), and mass transfer (oxygen partial pressure and saturation). Through the design optimization, an optimized APL device was computationally derived. A physical prototype of the designed APL device was fabricated and tested in vitro. The experimental data showed that the optimized APL can provide adequate blood pumping and oxygen transfer over the range of intended operating conditions.
Collapse
Affiliation(s)
- M. Ertan Taskin
- Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, Baltimore, MD 21201
| | - Tao Zhang
- Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, Baltimore, MD 21201
| | - Katharine H. Fraser
- Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, Baltimore, MD 21201
| | - Bartley P. Griffith
- Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, Baltimore, MD 21201
| | - Zhongjun J. Wu
- Artificial Organs Laboratory, Department of Surgery, University of Maryland School of Medicine, Baltimore, MD 21201
| |
Collapse
|
12
|
Govindarajan V, Udaykumar HS, Chandran KB. FLOW DYNAMIC COMPARISON BETWEEN RECESSED HINGE AND OPEN PIVOT BI-LEAFLET HEART VALVE DESIGNS. J MECH MED BIOL 2011; 9:161-176. [PMID: 19865586 DOI: 10.1142/s0219519409002912] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The flow dynamics through the peripheral and hinge regions of a bi-leaflet mechanical heart valve are complex and result in abnormally high shear stresses particularly during the closing phase of the valve function. It has been observed that, the late stages of closure is more significant in the dynamics of platelet activation; therefore, the later stages of closure is simulated by solving the two-dimensional Navier-Stokes equations using an Eulerian Levelset based sharp interface Cartesian grid method. Using a fixed Cartesian mesh incorporating local mesh refinement for solution accuracy and efficiency, the flow through and within a recessed hinge design and an open pivot hinge design is compared. Platelets are modelled as point particles by Lagrangian particle tracking algorithm with one way coupling. A dilute particle flow is assumed and particle-particle interactions are neglected. It was observed that the hinge region of the open pivot valve indicated a lower potential for activation of platelets compared to that in valves with a recessed hinge design.
Collapse
Affiliation(s)
- V Govindarajan
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA-52242
| | | | | |
Collapse
|
13
|
Gkanis V, Housiadas C. Dynamics of Flow in a Mechanical Heart Valve: The Role of Leaflet Inertia and Leaflet Compliance. J Biomech Eng 2011; 133:041009. [DOI: 10.1115/1.4003673] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In this work, we examine the dynamics of fluid flow in a mechanical heart valve when the solid inertia and leaflet compliance are important. The fluid is incompressible and Newtonian, and the leaflet is an incompressible neo-Hookean material. In the case of an inertialess leaflet, we find that the maximum valve opening angle and the time that the valve remains closed increase as the shear modulus of the leaflet decreases. More importantly, the regurgitant volume decreases with decreasing shear modulus. When we examined the forces exerted on the leaflet, we found that the downward motion of the leaflet is initiated by a vertical force exerted on its right side and, later on, by a vertical force exerted on the top side of the leaflet. In the case of solid inertia, we find that the maximum valve opening angle and the regurgitant volume are larger than in the case of an inertialess leaflet. These results highlight the importance of solid compliance in the dynamics of blood flow in a mechanical heart valve. More importantly, they indicate that mechanical heart valves with compliant leaflets may have smaller regurgitant volumes and smaller shear stresses than the ones with rigid leaflets.
Collapse
Affiliation(s)
- Vasileios Gkanis
- Thermal Hydraulics and Multiphase Flow Laboratory, INT-RP, National Center for Scientific Research “Demokritos,” Agia Paraskevi, 15310 Athens, Greece
| | - Christos Housiadas
- Thermal Hydraulics and Multiphase Flow Laboratory, INT-RP, National Center for Scientific Research “Demokritos,” Agia Paraskevi, 15310 Athens, Greece
| |
Collapse
|
14
|
Borazjani I, Sotiropoulos F. The effect of implantation orientation of a bileaflet mechanical heart valve on kinematics and hemodynamics in an anatomic aorta. J Biomech Eng 2011; 132:111005. [PMID: 21034146 DOI: 10.1115/1.4002491] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We carry out three-dimensional high-resolution numerical simulations of a bileaflet mechanical heart valve under physiologic pulsatile flow conditions implanted at different orientations in an anatomic aorta obtained from magnetic resonance imaging (MRI) of a volunteer. We use the extensively validated for heart valve flow curvilinear-immersed boundary (CURVIB) fluid-structure interaction (FSI) solver in which the empty aorta is discretized with a curvilinear, aorta-conforming grid while the valve is handled as an immersed boundary. The motion of the valve leaflets are calculated through a strongly coupled FSI algorithm implemented in conjunction with the Aitken convergence acceleration technique. We perform simulations for three valve orientations, which differ from each other by 45 deg and compare the results in terms of leaflet motion and flow field. We show that the valve implanted symmetrically relative to the symmetry plane of the ascending aorta curvature exhibits the smallest overall asymmetry in the motion of its two leaflets and lowest rebound during closure. Consequently, we hypothesize that this orientation is beneficial to reduce the chance of intermittent regurgitation. Furthermore, we find that the valve orientation does not significantly affect the shear stress distribution in the aortic lumen, which is in agreement with previous studies.
Collapse
Affiliation(s)
- Iman Borazjani
- St. Anthony Falls Laboratory, University of Minnesota, Minneapolis, MN 55414, USA.
| | | |
Collapse
|
15
|
Influence of three mechanical bileaflet prosthetic valve designs on the three-dimensional flow field inside a simulated aorta. J Artif Organs 2010; 13:207-17. [PMID: 20924771 DOI: 10.1007/s10047-010-0519-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2010] [Accepted: 09/15/2010] [Indexed: 10/19/2022]
Abstract
The current design of the bileaflet valve, the leaflets of which open outside first, differs significantly from the natural valve whose leaflets open center first. This difference generates a completely different flow field in the bileaflet valve compared to that in the natural heart valve. In a previous study, it was demonstrated that the valve design greatly affects the aortic flow field as well as the circulatory flow inside sinuses of Valsalva, using saline solution as a working fluid. A limited discussion on the turbulence flow field that could be generated by the valve was provided. In this continuation of that study, therefore, a dynamic PIV study was conducted to analyze the influence of the heart valve design on the aortic flow field, and particularly on the turbulent profile. This study also aimed to determine the influence of the viscosity of the testing fluid. Three bileaflet prostheses-the St. Jude Medical (SJM), the On-X, and the MIRA valves-were tested under pulsatile flow conditions. Flow through the central orifice of the SJM valve was slower than that through the newer designs. The newer designs tend to show strong flow through all orifices. The On-X valve generates simple jet-type flow while the MIRA valve with circumferentially curved leaflets generates a strong but three-dimensionally diffuse flow, resulting in a more complex flow field downstream of the aortic valve with higher turbulence. A 180° orientation that is more popular clinically seems to provide a less diffuse flow than a 90° orientation. The effect of increasing the viscosity was found to be an increase in the flow velocity through the central orifice and a more organized flow field for all of the valves tested.
Collapse
|
16
|
Flow interactions with cells and tissues: cardiovascular flows and fluid-structure interactions. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008, Pasadena, California. Ann Biomed Eng 2010; 38:1178-87. [PMID: 20336826 DOI: 10.1007/s10439-010-9900-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Interactions between flow and biological cells and tissues are intrinsic to the circulatory, respiratory, digestive and genitourinary systems. In the circulatory system, an understanding of the complex interaction between the arterial wall (a living multi-component organ with anisotropic, nonlinear material properties) and blood (a shear-thinning fluid with 45% by volume consisting of red blood cells, platelets, and white blood cells) is vital to our understanding of the physiology of the human circulation and the etiology and development of arterial diseases, and to the design and development of prosthetic implants and tissue-engineered substitutes. Similarly, an understanding of the complex dynamics of flow past native human heart valves and the effect of that flow on the valvular tissue is necessary to elucidate the etiology of valvular diseases and in the design and development of valve replacements. In this paper we address the influence of biomechanical factors on the arterial circulation. The first part presents our current understanding of the impact of blood flow on the arterial wall at the cellular level and the relationship between flow-induced stresses and the etiology of atherosclerosis. The second part describes recent advances in the application of fluid-structure interaction analysis to arterial flows and the dynamics of heart valves.
Collapse
|
17
|
Murphy DW, Dasi LP, Vukasinovic J, Glezer A, Yoganathan AP. Reduction of Procoagulant Potential of b-Datum Leakage Jet Flow in Bileaflet Mechanical Heart Valves via Application of Vortex Generator Arrays. J Biomech Eng 2010; 132:071011. [DOI: 10.1115/1.4001260] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Current designs of bileaflet mechanical heart valves put patients at an increased risk of thromboembolism. In particular, regurgitant flow through the b-datum line is associated with nonphysiologic flow characteristics such as elevated shear stresses, regions of recirculation, and increased mixing, all of which may promote thrombus formation. We have previously shown that passive flow control in the form of vortex generators mounted on the downstream leaflet surfaces can effectively diminish turbulent stresses. The objective of the current work is thus to determine the effect of vortex generators on the thromboembolic potential of the b-datum line leakage jet and to correlate that effect with the vortex generator-induced changes to the flow structure. Flow experiments were performed using a steady model of the transient b-datum line jet. These experiments encompassed flow visualization to gain an overall picture of the flow system, particle image velocimetry to quantify the flow field in detail, and in vitro experiments with human blood to quantify thrombus formation in response to the applied passive flow control. Thrombus formation was quantified over time by an assay for thrombin-antithrombin III (TAT III). In comparing results with and without vortex generators, significantly lower mean TAT III levels were observed at one time point for the case with vortex generators. Also, the TAT III growth rate of the case with vortex generators was significantly lower. While no differences in jet spreading were found with and without vortex generators, lower peak turbulent stresses were observed for the case with vortex generators. The results thus demonstrate the potential of applying passive flow control to cardiovascular hardware in order to mitigate the hemodynamic factors leading to thrombus formation.
Collapse
Affiliation(s)
- David W. Murphy
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0405
| | - Lakshmi P. Dasi
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523-1374
| | - Jelena Vukasinovic
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0405
| | - Ari Glezer
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0405
| | - Ajit P. Yoganathan
- The Wallace H. Coulter Distinguished Faculty Chair of Biomedical Engineering and Regents Professor Associate Chair of Research Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332-0535
| |
Collapse
|
18
|
Bluestein D, Chandran KB, Manning KB. Towards non-thrombogenic performance of blood recirculating devices. Ann Biomed Eng 2010; 38:1236-56. [PMID: 20131098 PMCID: PMC2862578 DOI: 10.1007/s10439-010-9905-9] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2009] [Accepted: 01/02/2010] [Indexed: 10/19/2022]
Abstract
Implantable blood recirculating devices have provided life saving solutions to patients with severe cardiovascular diseases. However, common problems of hemolysis and thromboembolism remain an impediment to these devices. In this article, we present a brief review of the work by several groups in the field that has led to the development of new methodologies that may facilitate achieving the daunting goal of optimizing the thrombogenic performance of blood recirculating devices. The aim is to describe work which pertains to the interaction between flow-induced stresses and the blood constituents, and that supports the hypothesis that thromboembolism in prosthetic blood recirculating devices is initiated and maintained primarily by the non-physiological flow patterns and stresses that activate and enhance the aggregation of blood platelets, increasing the risk of thromboembolism and cardioembolic stroke. Such work includes state-of-the-art numerical and experimental tools used to elucidate flow-induced mechanisms leading to thromboembolism in prosthetic devices. Following the review, the paper describes several efforts conducted by some of the groups active in the field, and points to several directions that should be pursued in the future in order to achieve the goal for blood recirculating prosthetic devices becoming more effective as destination therapy in the future.
Collapse
Affiliation(s)
- D Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA.
| | | | | |
Collapse
|
19
|
Abstract
Computational simulations are playing an increasingly important role in enhancing our understanding of the normal human physiological function, etiology of diseased states, surgical and interventional planning, and in the design and evaluation of artificial implants. Researchers are taking advantage of computational simulations to speed up the initial design of implantable devices before a prototype is developed and hence able to reduce animal experimentation for the functional evaluation of the devices under development. A review of the reported studies to date relevant to the simulation of the native and prosthetic heart valve dynamics is the subject of the present paper. Potential future directions toward multi-scale simulation studies for our further understanding of the physiology and pathophysiology of heart valve dynamics and valvular implants are also discussed.
Collapse
|
20
|
Govindarajan V, Udaykumar HS, Herbertson LH, Deutsch S, Manning KB, Chandran KB. Two-dimensional FSI simulation of closing dynamics of a tilting disc mechanical heart valve. J Med Device 2010; 4:11001. [PMID: 20209095 DOI: 10.1115/1.4000876] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
The fluid dynamics during valve closure resulting in high shear flows and large residence times of particles has been implicated in platelet activation and thrombus formation in mechanical heart valves. Our previous studies with bi-leaflet valves have shown that large shear stresses induced in the gap between the leaflet edge and the valve housing results in relatively high platelet activation levels whereas flow between the leaflets results in shed vortices not conducive to platelet damage. In this study we compare the result of closing dynamics of a tilting disc valve with that of a bi-leaflet valve. The two-dimensional fluid-structure interaction analysis of a tilting disc valve closure mechanics is performed with a fixed grid Cartesian mesh flow solver with local mesh refinement, and a Lagrangian particle dynamic analysis for computation of potential for platelet activation. Throughout the simulation the flow remains in the laminar regime and the flow through the gap width is marked by the development of a shear layer which separates from the leaflet downstream of the valve. Zones of re-circulation are observed in the gap between the leaflet edge and the valve housing on the major orifice region of the tilting disc valve and are seen to be migrating towards the minor orifice region. Jet flow is observed at the minor orifice region and a vortex is formed which sheds in the direction of fluid motion as observed in experiments using PIV measurements. The activation parameter computed for the tilting disc valve, at the time of closure was found to be 2.7 times greater than that of the bi-leaflet mechanical valve and was found to be in the vicinity of the minor orifice region mainly due to the migration of vortical structures from the major to the minor orifice region during the leaflet rebound of the closing phase.
Collapse
Affiliation(s)
- V Govindarajan
- Department of Biomedical Engineering, University of Iowa, Iowa City, IA-52242 USA
| | | | | | | | | | | |
Collapse
|
21
|
Numerical analysis on the hemodynamics and leaflet dynamics in a bileaflet mechanical heart valve using a fluid-structure interaction method. ASAIO J 2009; 55:428-37. [PMID: 19730001 DOI: 10.1097/mat.0b013e3181b58f98] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Bileaflet mechanical heart valves (BMHVs) are widely implanted to replace diseased heart valves but still suffer from complications such as hemolysis and platelet activation. These complications are closely related to both flow characteristics through the valves and leaflet dynamics. In this study, a fluid-structure interaction (FSI) simulation is performed to investigate the characteristics of physiological flow interacting with moving leaflets in a BMHV. The present FSI model uses both a finite volume computational fluid dynamics code and a finite element structure dynamics code to solve the governing equations for fluid flow and leaflet dynamics. In addition, a structural analysis is performed with the forces acting on the leaflet surfaces. From the analysis, detailed flow information and leaflet behavior are quantified for a cardiac cycle. The results show that the present FSI model performs well at predicting the overall flow patterns interacting with the moving leaflets and leaflet behavior in the BMHV.
Collapse
|
22
|
Govindarajan V, Udaykumar HS, Chandran KB. Two-dimensional simulation of flow and platelet dynamics in the hinge region of a mechanical heart valve. J Biomech Eng 2009; 131:031002. [PMID: 19154061 DOI: 10.1115/1.3005158] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The hinge region of a mechanical bileaflet valve is implicated in blood damage and initiation of thrombus formation. Detailed fluid dynamic analysis in the complex geometry of the hinge region during the closing phase of the bileaflet valve is the focus of this study to understand the effect of fluid-induced stresses on the activation of platelets. A fixed-grid Cartesian mesh flow solver is used to simulate the blood flow through a two-dimensional geometry of the hinge region of a bileaflet mechanical valve. Use of local mesh refinement algorithm provides mesh adaptation based on the gradients of flow in the constricted geometry of the hinge. Leaflet motion is specified from the fluid-structure interaction analysis of the leaflet dynamics during the closing phase from a previous study, which focused on the fluid mechanics at the gap between the leaflet edges and the valve housing. A Lagrangian particle tracking method is used to model and track the platelets and to compute the magnitude of the shear stress on the platelets as they pass through the hinge region. Results show that there is a boundary layer separation in the gaps between the leaflet ear and the constricted hinge geometry. Separated shear layers roll up into vortical structures that lead to high residence times combined with exposure to high-shear stresses for particles in the hinge region. Particles are preferentially entrained into this recirculation zone, presenting the possibility of platelet activation, aggregation, and initiation of thrombi.
Collapse
Affiliation(s)
- V Govindarajan
- Department of Biomedical Engineering, College of Engineering, The University of lowa, 1402 SC, lowa City, IA 52242, USA
| | | | | |
Collapse
|
23
|
Sotiropoulos F, Borazjani I. A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves. Med Biol Eng Comput 2009; 47:245-56. [PMID: 19194734 PMCID: PMC2717171 DOI: 10.1007/s11517-009-0438-z] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2008] [Accepted: 01/03/2009] [Indexed: 11/25/2022]
Abstract
In nearly half of the heart valve replacement surgeries performed annually, surgeons prefer to implant bileaflet mechanical heart valves (BMHV) because of their durability and long life span. All current BMHV designs, however, are prone to thromboembolic complications and implant recipients need to be on a life-long anticoagulant medication regiment. Non-physiologic flow patterns and turbulence generated by the valve leaflets are believed to be the major culprit for the increased risk of thromboembolism in BMHV implant recipients. In this paper, we review recent advances in developing predictive fluid-structure interaction (FSI) algorithms that can simulate BMHV flows at physiologic conditions and at resolution sufficiently fine to start probing the links between hemodynamics and blood-cell damage. Numerical simulations have provided the first glimpse into the complex hemodynamic environment experienced by blood cells downstream of the valve leaflets and successfully resolved for the first time the experimentally observed explosive transition to a turbulent-like state at the start of the decelerating flow phase. The simulations have also resolved a number of subtle features of experimentally observed valve kinematics, such as the asymmetric opening and closing of the leaflets and the leaflet rebound during closing. The paper also discusses a future research agenda toward developing a powerful patient-specific computational framework for optimizing valve design and implantation in a virtual surgery environment.
Collapse
Affiliation(s)
- Fotis Sotiropoulos
- St Anthony Falls Laboratory, University of Minnesota, 2 Third Ave SE, Minneapolis, MN 55414, USA, e-mail: ,
| | - Iman Borazjani
- St Anthony Falls Laboratory, University of Minnesota, 2 Third Ave SE, Minneapolis, MN 55414, USA, e-mail: ,
| |
Collapse
|
24
|
Borazjani I, Ge L, Sotiropoulos F. Curvilinear Immersed Boundary Method for Simulating Fluid Structure Interaction with Complex 3D Rigid Bodies. JOURNAL OF COMPUTATIONAL PHYSICS 2008; 227:7587-7620. [PMID: 20981246 PMCID: PMC2963478 DOI: 10.1016/j.jcp.2008.04.028] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The sharp-interface CURVIB approach of Ge and Sotiropoulos [L. Ge, F. Sotiropoulos, A Numerical Method for Solving the 3D Unsteady Incompressible Navier-Stokes Equations in Curvilinear Domains with Complex Immersed Boundaries, Journal of Computational Physics 225 (2007) 1782-1809] is extended to simulate fluid structure interaction (FSI) problems involving complex 3D rigid bodies undergoing large structural displacements. The FSI solver adopts the partitioned FSI solution approach and both loose and strong coupling strategies are implemented. The interfaces between immersed bodies and the fluid are discretized with a Lagrangian grid and tracked with an explicit front-tracking approach. An efficient ray-tracing algorithm is developed to quickly identify the relationship between the background grid and the moving bodies. Numerical experiments are carried out for two FSI problems: vortex induced vibration of elastically mounted cylinders and flow through a bileaflet mechanical heart valve at physiologic conditions. For both cases the computed results are in excellent agreement with benchmark simulations and experimental measurements. The numerical experiments suggest that both the properties of the structure (mass, geometry) and the local flow conditions can play an important role in determining the stability of the FSI algorithm. Under certain conditions unconditionally unstable iteration schemes result even when strong coupling FSI is employed. For such cases, however, combining the strong-coupling iteration with under-relaxation in conjunction with the Aitken's acceleration technique is shown to effectively resolve the stability problems. A theoretical analysis is presented to explain the findings of the numerical experiments. It is shown that the ratio of the added mass to the mass of the structure as well as the sign of the local time rate of change of the force or moment imparted on the structure by the fluid determine the stability and convergence of the FSI algorithm. The stabilizing role of under-relaxation is also clarified and an upper bound of the required for stability under-relaxation coefficient is derived.
Collapse
Affiliation(s)
- Iman Borazjani
- St. Anthony Falls Laboratory, University of Minnesota, 2 Third Avenue SE, Minneapolis, MN 55414
| | | | | |
Collapse
|
25
|
Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses. J Artif Organs 2008; 11:75-90. [PMID: 18604612 DOI: 10.1007/s10047-008-0410-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2008] [Accepted: 04/15/2008] [Indexed: 10/21/2022]
Abstract
The characteristics of mechanical bileaflet valves, the leaflets of which open at the outside first, differ significantly from those of natural valves, whose leaflets open at the center first, and this fact affects the flow field down-stream of the valves. The direction of jet-type flows, which is influenced by this difference in valve features, and the existence of the sinus of Valsalva both affect the flow field inside the aorta in different ways, depending on the valve design. There may also be an influence on the coronary circulation, the entrance to which resides inside the sinus of Valsalva. A dynamic particle image velocimetry (PIV) study was conducted to analyze the influence of the design of prosthetic heart valves on the aortic flow field. Three contemporary bileaflet prostheses, the St. Jude Medical (SJM) valve, the On-X valve (with straight leaflets), and the MIRA valve (with curved leaflets), were tested inside a simulated aorta under pulsatile flow conditions. A dynamic PIV system was employed to analyze the aortic flow field resulting from the different valve designs. The two newer valves, the On-X and the MIRA valves, open more quickly than the SJM valve and provide a wider opening area when the valve is fully open. The SJM valve's outer orifices deflect the flow during the accelerating flow phase, whereas the newer designs deflect the flow less. The flow through the central orifice of the SJM valve has a lower velocity compared to the newer designs; the newer designs tend to have a strong flow through all orifices. The On-X valve generates a simple jet-type flow, whereas the MIRA valve (with circumferentially curved leaflets) generates a strong but three-dimensionally diffuse flow, resulting in a more complex flow field downstream of the aortic valve. The clinically more adapted 180 degrees orientation seems to provide a less diffuse flow than the 90 degrees orientation does. The small differences in leaflet design in the bileaflet valves generate noticeable differences in the aortic flow; the newer valves show strong flows through all orifices.
Collapse
|
26
|
Scull SA, Dow MB, Athreya BH. Physical and occupational therapy for children with rheumatic diseases. J Biomech Eng 1986; 133:121004. [PMID: 3489919 DOI: 10.1115/1.4005478] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Total management of rheumatic disorders of children includes antiinflammatory drugs, active therapy, maintenance of ADLs, and attention to the psychosocial development of the child. This article focuses on the role that physical and occupational therapists play in the management of children with arthritis. The complexity of the problems of these children necessitates a multidisciplinary team approach, with professionals who are committed to helping the child lead as normal a life as possible. This objective can be accomplished only by teaching families and school personnel how to manage the child's daily therapeutic needs.
Collapse
|