1
|
Ghorbannia A, LaDisa JF. Intravascular imaging of angioplasty balloon under-expansion during pre-dilation predicts hyperelastic behavior of coronary artery lesions. Front Bioeng Biotechnol 2023; 11:1192797. [PMID: 37284239 PMCID: PMC10240066 DOI: 10.3389/fbioe.2023.1192797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 05/08/2023] [Indexed: 06/08/2023] Open
Abstract
Introduction: Stent-induced mechanical stimuli cause pathophysiological responses in the coronary artery post-treatment. These stimuli can be minimized through choice of stent, size, and deployment strategy. However, the lack of target lesion material characterization is a barrier to further personalizing treatment. A novel ex-vivo angioplasty-based intravascular imaging technique using optical coherence tomography (OCT) was developed to characterize local stiffness of the target lesion. Methods: After proper institutional oversight, atherosclerotic coronary arteries (n = 9) were dissected from human donor hearts for ex vivo material characterization <48 h post-mortem. Morphology was imaged at the diastolic blood pressure using common intravascular OCT protocols and at subsequent pressures using a specially fabricated perfusion balloon that accommodates the OCT imaging wire. Balloon under-expansion was quantified relative to the nominal balloon size at 8 ATM. Correlation to a constitutive hyperelastic model was empirically investigated (n = 13 plaques) using biaxial extension results fit to a mixed Neo-Hookean and Exponential constitutive model. Results and discussion: The average circumferential Cauchy stress was 66.5, 130.2, and 300.4 kPa for regions with <15, 15-30, and >30% balloon under-expansion at a 1.15 stretch ratio. Similarly, the average longitudinal Cauchy stress was 68.1, 172.6, and 412.7 kPa, respectively. Consequently, strong correlation coefficients >0.89 were observed between balloon under-expansion and stress-like constitutive parameters. These parameters allowed for visualization of stiffness and material heterogeneity for a range of atherosclerotic plaques. Balloon under-expansion is a strong predictor of target lesion stiffness. These findings are promising as stent deployment could now be further personalized via target lesion material characterization obtained pre-operatively.
Collapse
Affiliation(s)
- Arash Ghorbannia
- Section of Pediatric Cardiology, Department of Pediatrics, Medical College of Wisconsin, Milwaukee, WI, United States
- Herma Heart Institute, Children’s Wisconsin, Milwaukee, WI, United States
- Department of Biomedical Engineering, Marquette University and The Medical College of Wisconsin, Milwaukee, WI, United States
| | - John F. LaDisa
- Section of Pediatric Cardiology, Department of Pediatrics, Medical College of Wisconsin, Milwaukee, WI, United States
- Herma Heart Institute, Children’s Wisconsin, Milwaukee, WI, United States
- Department of Biomedical Engineering, Marquette University and The Medical College of Wisconsin, Milwaukee, WI, United States
- Department of Physiology, Milwaukee, WI, United States
- Division of Cardiovascular Medicine, Medical College of Wisconsin, Milwaukee, WI, United States
| |
Collapse
|
2
|
Lenzuni M, Bonfadini S, Criante L, Zorzi F, Summa M, Bertorelli R, Suarato G, Athanassiou A. Dynamic investigation of zein-based degradable and hemocompatible coatings for drug-eluting stents: a microfluidic approach. LAB ON A CHIP 2023; 23:1576-1592. [PMID: 36688523 DOI: 10.1039/d3lc00012e] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Biodegradable stent coatings have shown great potential in terms of delivering drugs to a damaged vessel wall, and their release profiles are key elements governing the overall performance of drug-eluting stents (DESs). However, release and degradation kinetics are usually not tested under simulated physiological conditions or in dynamic environments, both essential aspects in the design of novel DESs. To bridge this gap, fused silica-based microfluidic systems, with either round or square channel cross-sections, were designed to mimic the microenvironment of a stented vessel. In particular, we fabricated and characterized microfluidic chips based on customizable channels, which were spray-coated with a naturally-derived, rutin-loaded zein solution, to perform a comprehensive study under flow conditions. Dynamic assays after 6 hours showed how the degradation of the zein matrix was affected by the cross-sectional conformation (∼69% vs. ∼61%, square and round channel, respectively) and the simulated blood fluid components (∼55%, round channel with a more viscous solution). The released amount of rutin was ∼81% vs. ∼77% and ∼78% vs. ∼74% from the square and round channels, using the less and more viscous blood-simulated fluids, respectively. Fitting the drug release data to Korsmeyer-Peppas and first-order mathematical models provided further insight into the mechanism of rutin release and coating behavior under flowing conditions. More importantly, whole blood tests with our newly developed microfluidic platforms confirmed the hemocompatibility of our zein-based coating. In detail, in-flow and static studies on the blood cell behavior showed a significant reduction of platelet adhesion (∼73%) and activation (∼93%) compared to the stainless-steel substrate, confirming the benefits of using such naturally-derived coatings to avoid clogging. Overall, our microfluidic designs can provide a key practical tool for assessing polymer degradation and drug release from degradable matrices under flowing conditions, thus aiding future studies on the development of hemocompatible, controlled-release coatings for DESs.
Collapse
Affiliation(s)
- Martina Lenzuni
- Smart Materials Group, Istituto Italiano di Tecnologia, via Morego 30, Genoa, Italy.
- Department of Computer Science, Bioengineering, Robotics and Systems Engineering, University of Genoa, via Opera Pia 13, Genoa, Italy
| | - Silvio Bonfadini
- Center for Nano Science and Technology @ PoliMi, Istituto Italiano di Tecnologia, via Pascoli 70/3, Milan, Italy
| | - Luigino Criante
- Center for Nano Science and Technology @ PoliMi, Istituto Italiano di Tecnologia, via Pascoli 70/3, Milan, Italy
| | - Filippo Zorzi
- Center for Nano Science and Technology @ PoliMi, Istituto Italiano di Tecnologia, via Pascoli 70/3, Milan, Italy
- Department of Physics, Politecnico di Milano, Piazza Leonardo da Vinci, 32, Milan, Italy
| | - Maria Summa
- Translational Pharmacology, Istituto Italiano di Tecnologia, via Morego 30, Genoa, Italy
| | - Rosalia Bertorelli
- Translational Pharmacology, Istituto Italiano di Tecnologia, via Morego 30, Genoa, Italy
| | - Giulia Suarato
- Smart Materials Group, Istituto Italiano di Tecnologia, via Morego 30, Genoa, Italy.
- Translational Pharmacology, Istituto Italiano di Tecnologia, via Morego 30, Genoa, Italy
| | | |
Collapse
|
3
|
Song Y, Jing H, Vong LB, Wang J, Li N. Recent advances in targeted stimuli-responsive nano-based drug delivery systems combating atherosclerosis. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.10.055] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
4
|
Li L, Liu S, Tan J, Wei L, Wu D, Gao S, Weng Y, Chen J. Recent advance in treatment of atherosclerosis: Key targets and plaque-positioned delivery strategies. J Tissue Eng 2022; 13:20417314221088509. [PMID: 35356091 PMCID: PMC8958685 DOI: 10.1177/20417314221088509] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Atherosclerosis, a chronic inflammatory disease of vascular wall, is a progressive pathophysiological process with lipids oxidation/depositing initiation and innate/adaptive immune responses. The coordination of multi systems covering oxidative stress, dysfunctional endothelium, diseased lipid uptake, cell apoptosis, thrombotic and pro-inflammatory responding as well as switched SMCs contributes to plaque growth. In this circumstance, inevitably, targeting these processes is considered to be effective for treating atherosclerosis. Arriving, retention and working of payload candidates mediated by targets in lesion direct ultimate therapeutic outcomes. Accumulating a series of scientific studies and clinical practice in the past decades, lesion homing delivery strategies including stent/balloon/nanoparticle-based transportation worked as the potent promotor to ensure a therapeutic effect. The objective of this review is to achieve a very brief summary about the effective therapeutic methods cooperating specifical targets and positioning-delivery strategies in atherosclerosis for better outcomes.
Collapse
Affiliation(s)
- Li Li
- Key Laboratory of Advanced Technology of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, PR China
| | - Sainan Liu
- Key Laboratory of Advanced Technology of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, PR China
| | - Jianying Tan
- Key Laboratory of Advanced Technology of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, PR China
| | - Lai Wei
- Key Laboratory of Advanced Technology of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, PR China
| | - Dimeng Wu
- Chengdu Daxan Innovative Medical Tech. Co., Ltd., Chengdu, PR China
| | - Shuai Gao
- Chengdu Daxan Innovative Medical Tech. Co., Ltd., Chengdu, PR China
| | - Yajun Weng
- Key Laboratory of Advanced Technology of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, PR China
| | - Junying Chen
- Key Laboratory of Advanced Technology of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, PR China
| |
Collapse
|
5
|
Razzi F, Lovrak M, Gruzdyte D, Den Hartog Y, Duncker DJ, van Esch JH, van Steijn V, van Beusekom HMM. An Implantable Artificial Atherosclerotic Plaque as a Novel Approach for Drug Transport Studies on Drug-Eluting Stents. Adv Healthc Mater 2022; 11:e2101570. [PMID: 34865315 PMCID: PMC11469272 DOI: 10.1002/adhm.202101570] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 10/31/2021] [Indexed: 11/11/2022]
Abstract
Atherosclerotic arteries are commonly treated using drug-eluting stents (DES). However, it remains unclear whether and how the properties of atherosclerotic plaque affect drug transport in the arterial wall. A limitation of the currently used atherosclerotic animal models to study arterial drug distribution is the unpredictability of plaque size, composition, and location. In the present study, the aim is to create an artificial atherosclerotic plaque-of reproducible and controllable complexity and implantable at specific locations-to enable systematic studies on transport phenomena of drugs in stented atherosclerosis-mimicking arteries. For this purpose, mixtures of relevant lipids at concentrations mimicking atherosclerotic plaque are incorporated in gelatin/alginate hydrogels. Lipid-free (control) and lipid-rich hydrogels (artificial plaque) are created, mounted on DES and successfully implanted in porcine coronary arteries ex-vivo. Matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI-MSI) is used to measure local drug distribution in the arterial wall behind the prepared hydrogels, showing that the lipid-rich hydrogel significantly hampers drug transport as compared to the lipid-free hydrogel. This observation confirms the importance of studying drug transport phenomena in the presence of lipids and of having an experimental model in which lipids and other plaque constituents can be precisely controlled and systematically studied.
Collapse
Affiliation(s)
- Francesca Razzi
- Department of Experimental CardiologyErasmus Medical CenterDoctor Molewaterplein 40Rotterdam3015 GDThe Netherlands
| | - Matija Lovrak
- Department of Chemical EngineeringDelft University of TechnologyVan der Maasweg 9Delft2629 HZThe Netherlands
| | - Dovile Gruzdyte
- Department of Experimental CardiologyErasmus Medical CenterDoctor Molewaterplein 40Rotterdam3015 GDThe Netherlands
| | - Yvette Den Hartog
- Department of Experimental CardiologyErasmus Medical CenterDoctor Molewaterplein 40Rotterdam3015 GDThe Netherlands
| | - Dirk J. Duncker
- Department of Experimental CardiologyErasmus Medical CenterDoctor Molewaterplein 40Rotterdam3015 GDThe Netherlands
| | - Jan H. van Esch
- Department of Chemical EngineeringDelft University of TechnologyVan der Maasweg 9Delft2629 HZThe Netherlands
| | - Volkert van Steijn
- Department of Chemical EngineeringDelft University of TechnologyVan der Maasweg 9Delft2629 HZThe Netherlands
| | - Heleen M. M. van Beusekom
- Department of Experimental CardiologyErasmus Medical CenterDoctor Molewaterplein 40Rotterdam3015 GDThe Netherlands
| |
Collapse
|
6
|
King D, McCormick C, McGinty S. How Does Fluid Flow Influence Drug Release from Drug Filled Implants? Pharm Res 2022; 39:25-40. [PMID: 34997423 PMCID: PMC8837542 DOI: 10.1007/s11095-021-03127-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 10/15/2021] [Indexed: 11/13/2022]
Abstract
Drug-filled implants (DFIs) have emerged as an innovative approach to control the delivery of drugs. These devices contain the drug within the structure of the implant itself and avoid the need to include additional drug carrier materials such as a polymers, which are often associated with inflammation and delayed healing/tissue regeneration at the implant site. One common feature of in vitro experiments to generate drug release profiles is stirring or agitation of the release medium. However, the influence of the resulting fluid flow on the rate of drug release from DFIs has yet to be quantified. In this paper we consider two DFIs, which although similar in shape and size, employ different strategies to control the release of drug: a porous pin with pores on the order of μm and a pin drilled with orifices of the order of mm. We develop a multiphysics mathematical model of drug release from these DFIs, subject to fluid flow induced through stirring and show that fluid flow greatly influences the drug release profile for the orifice pin, but that the porous pin drug release profile is relatively insensitive to flow. We demonstrate that drug release from the porous pin may adequately be described through a simplified radial 1D dissolution-diffusion model, while a 3D dissolution-advection-diffusion model is required to describe drug release from the orifice pin. A sensitivity analysis reveals that that the balance of reaction-advection-diffusion in terms of key nondimensional numbers governs the overall drug release. Our findings potentially have important implications in terms of devising the most relevant experimental protocol for quantifying drug release from DFIs.
Collapse
Affiliation(s)
- David King
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK
| | | | - Sean McGinty
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK. .,Glasgow Computational Engineering Centre, University of Glasgow, Glasgow, UK.
| |
Collapse
|
7
|
Biswas S, Sarifuddin, Mandal PK. An unsteady analysis of two-phase binding of drug in an asymmetric stenosed vessel. Biomed Phys Eng Express 2021. [DOI: 10.1088/2057-1976/ac3d9b] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Abstract
In this paper, we investigate endovascular delivery to get a step ahead of the pharmacological limitations it has due to the complexity of dealing with a patient-specific vessel through a mathematical model. We divide the domain of computation into four sub-domains: the lumen, the lumen-tissue interface, the upper tissue and the lower tissue which are extracted from an asymmetric atherosclerotic image derived by the intravascular ultrasound (IVUS) technique. The injected drug at the luminal inlet is transported with the streaming blood which is considered Newtonian. An irreversible uptake kinetics of the injected drug at the lumen-tissue interface from the luminal side to the tissue domains is assumed. Subsequently, the drug is dispersed within the tissue followed by its retention in the extracellular matrix (ECM) and by receptor-mediated binding. The Marker and Cell (MAC) method has been leveraged to get a quantitative insight into the model considered. The effect of the wall absorption parameter on the concentration of all drug forms (free as well as two-phase bound) has been thoroughly investigated, and some other important factors, such as the averaged concentration, the tissue content, the fractional effect, the concentration variance and the effectiveness of drug have been graphically analyzed to gain a clear understanding of endovascular delivery. The simulated results predict that with increasing values of the absorption parameter, the averaged concentrations of all drug forms do decrease. An early saturation of binding sites takes place for smaller values of the absorption parameter, and also rapid saturation of ECM binding sites occurs as compared to receptor binding sites. Results also predict the influence of surface roughness as well as asymmetry of the domain about the centerline on the distribution and retention of drug. A thorough sensitivity analysis has been carried out to determine the influence of some parameters involved.
Collapse
|
8
|
Mandal AP, Mandal PK. Specific and nonspecific binding of drug eluted from a half-embedded stent in presence of atherosclerotic plaque. Comput Methods Biomech Biomed Engin 2021; 25:922-935. [PMID: 34615426 DOI: 10.1080/10255842.2021.1986813] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
This study is dealt with the two-phase binding (specific and nonspecific) of drug eluted from a half- embedded drug-eluting stent in presence of atherosclerotic plaque. The specific binding due to the interaction of drug molecules with specific receptors and nonspecific binding caused by the trapping of drug in the extra-cellular matrix have been paid due attention. An idealised wall consisting of a plaque and a healthy tissue region has been considered. Moreover, a Dirichlet release condition is imposed on the strut surface. In this investigation, a two-dimensional model governing drug transport and its two-phase binding in cylindrical polar coordinate system has been solved numerically by a finite-difference method. Our simulation predicts that plaque behaves like a physical barrier in two types of the binding process and there is an inverse relationship between bound drug concentration and plaque thickness. Simulations show that a single peak profile of drug is noted when the struts are situated one-strut radius apart and as the inter-strut distance increases, the peak concentration falls and distinct peak profiles over each strut are visualised. The model also reveals that in the region downstream of a strut, the concentration of both bound drug forms in the plaque and healthy regions increases, and eventually, the saturation length of binding sites increases. Predicted results show for smaller Damköhler number, the rapid saturation of binding sites takes place and the stent having thinner strut may perform well in terms of effectiveness as well as efficacy in the stent-based delivery.
Collapse
Affiliation(s)
- Akash Pradip Mandal
- Department of Mathematics, Ananda Chandra College, North Bengal University, Jalpaiguri, West Bengal, India
| | | |
Collapse
|
9
|
Ghorbanniahassankiadeh A, Marks DS, LaDisa JF. Correlation of Computational Instantaneous Wave-Free Ratio With Fractional Flow Reserve for Intermediate Multivessel Coronary Disease. J Biomech Eng 2021; 143:051011. [PMID: 33454732 DOI: 10.1115/1.4049746] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Indexed: 01/14/2023]
Abstract
This study computationally assesses the accuracy of an instantaneous wave-free ratio (iFR) threshold range compared to standard modalities such as fractional flow reserve (FFR) and coronary flow reserve (CFR) for multiple intermediate lesions near the left main (LM) coronary bifurcation. iFR is an adenosine-independent index encouraged for assessment of coronary artery disease (CAD), but different thresholds are debated. This becomes particularly challenging in cases of multivessel disease when sensitivity to downstream lesions is unclear. Idealized LM coronary arteries with 34 different intermediate stenoses were created and categorized (Medina) as single and multiple lesion groups. Computational fluid dynamics modeling was performed with physiologic boundary conditions using an open-source software (simvascular1) to solve the time-dependent Navier-Stokes equations. A strong linear relationship between iFR and FFR was observed among studied models, indicating computational iFR values of 0.92 and 0.93 are statistically equivalent to an FFR of 0.80 in single and multiple lesion groups, respectively. At the clinical FFR value (i.e., 0.8), a triple-lesion group had smaller CFR compared to the single and double lesion groups (e.g., triple = 3.077 versus single = 3.133 and double = 3.132). In general, the effect of additional intermediate downstream lesions (minimum lumen area > 3 mm2) was not statistically significant for iFR and CFR. A computational iFR of 0.92 best predicts an FFR of 0.80 and may be recommended as threshold criteria for computational assessment of LM stenosis following additional validation using patient-specific models.
Collapse
Affiliation(s)
- Arash Ghorbanniahassankiadeh
- Department of Biomedical Engineering, Medical College of Wisconsin and Marquette University, 8701 W Watertown Plank Road, Milwaukee, WI 53226
| | - David S Marks
- Division of Cardiovascular Medicine, Department of Medicine, Medical College of Wisconsin, 8701 W Watertown Plank Road, Milwaukee, WI 53226
| | - John F LaDisa
- Department of Biomedical Engineering, Medical College of Wisconsin and Marquette University, 8701 W Watertown Plank Road, Milwaukee, WI 53226; Department of Physiology, Medical College of Wisconsin, 8701 W Watertown Plank Road, Milwaukee, WI 53226; Department of Medicine, Medical College of Wisconsin, 8701 W Watertown Plank Road, Milwaukee, WI 53226
| |
Collapse
|
10
|
Escuer J, Aznar I, McCormick C, Peña E, McGinty S, Martínez MA. Influence of vessel curvature and plaque composition on drug transport in the arterial wall following drug-eluting stent implantation. Biomech Model Mechanobiol 2021; 20:767-786. [PMID: 33533998 DOI: 10.1007/s10237-020-01415-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Accepted: 12/21/2020] [Indexed: 01/03/2023]
Abstract
In the last decade, many computational models have been developed to describe the transport of drug eluted from stents and the subsequent uptake into arterial tissue. Each of these models has its own set of limitations: for example, models typically employ simplified stent and arterial geometries, some models assume a homogeneous arterial wall, and others neglect the influence of blood flow and plasma filtration on the drug transport process. In this study, we focus on two common limitations. Specifically, we provide a comprehensive investigation of the influence of arterial curvature and plaque composition on drug transport in the arterial wall following drug-eluting stent implantation. The arterial wall is considered as a three-layered structure including the subendothelial space, the media and the adventitia, with porous membranes separating them (endothelium, internal and external elastic lamina). Blood flow is modelled by the Navier-Stokes equations, while Darcy's law is used to calculate plasma filtration through the porous layers. Our findings demonstrate that arterial curvature and plaque composition have important influences on the spatiotemporal distribution of drug, with potential implications in terms of effectiveness of the treatment. Since the majority of computational models tend to neglect these features, these models are likely to be under- or over-estimating drug uptake and redistribution in arterial tissue.
Collapse
Affiliation(s)
- Javier Escuer
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
| | - Irene Aznar
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
| | | | - Estefanía Peña
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain.,Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Zaragoza, Spain
| | - Sean McGinty
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK
| | - Miguel A Martínez
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain. .,Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Zaragoza, Spain. .,, María de Luna, 3, 50018, Zaragoza, Spain.
| |
Collapse
|
11
|
Escuer J, Cebollero M, Peña E, McGinty S, Martínez MA. How does stent expansion alter drug transport properties of the arterial wall? J Mech Behav Biomed Mater 2020; 104:103610. [DOI: 10.1016/j.jmbbm.2019.103610] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 12/23/2019] [Accepted: 12/29/2019] [Indexed: 11/28/2022]
|
12
|
Feuerbach T, Kock S, Thommes M. Slicing parameter optimization for 3D printing of biodegradable drug-eluting tracheal stents. Pharm Dev Technol 2020; 25:650-658. [PMID: 32064994 DOI: 10.1080/10837450.2020.1727921] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
In 3D printing, the schematic representation of an object must be converted into machine commands. This process is called slicing. Depending on the slicing parameters, products with different properties are obtained. In this work, biodegradable drug-eluting tracheal stents consisting of a medical grade poly(lactic-co-glycolic acid) and a drug were printed by fused deposition modeling. A slicing parameter optimization method was proposed with the aim of obtaining a particularly low stent porosity and high mechanical strength while maintaining the stent dimensions, which is essential regarding patient-tailored implants. Depending on the three slicing parameters printing pattern, lateral strand distance and spatial fill, porosities of approximately 2-5% were obtained. The tensile strength was used as a measure for the mechanical strength of the implants and was found to be dependent on the porosity as well as the strand orientation relative to the load direction. Strand orientations in load direction yielded the highest tensile strengths of 40-46 MPa and the bonding between individual layers yielded the lowest tensile strengths of 20-24 MPa. In vitro dissolution tests of successfully printed stents were used to predict sustained release of the drug over several months.
Collapse
Affiliation(s)
- Tim Feuerbach
- Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany
| | - Stefanie Kock
- Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany
| | - Markus Thommes
- Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany
| |
Collapse
|
13
|
McKittrick CM, McKee S, Kennedy S, Oldroyd K, Wheel M, Pontrelli G, Dixon S, McGinty S, McCormick C. Combining mathematical modelling with in vitro experiments to predict in vivo drug-eluting stent performance. J Control Release 2019; 303:151-161. [PMID: 30878363 DOI: 10.1016/j.jconrel.2019.03.012] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 03/08/2019] [Accepted: 03/10/2019] [Indexed: 11/15/2022]
Abstract
In this study, we developed a predictive model of in vivo stent based drug release and distribution that is capable of providing useful insights into performance. In a combined mathematical modelling and experimental approach, we created two novel sirolimus-eluting stent coatings with quite distinct doses and release kinetics. Using readily measurable in vitro data, we then generated parameterised mathematical models of drug release. These were then used to simulate in vivo drug uptake and retention. Finally, we validated our model predictions against data on drug kinetics and efficacy obtained in a small in vivo evaluation. In agreement with the in vivo experimental results, our mathematical model predicted consistently higher sirolimus content in tissue for the higher dose stents compared with the lower dose stents. High dose stents resulted in statistically significant improvements in three key efficacy measures, providing further evidence of a basic relationship between dose and efficacy within DES. However, our mathematical modelling suggests a more complex relationship is at play, with efficacy being dependent not only on delivering an initial dose of drug sufficient to achieve receptor saturation, but also on the consequent drug release rate being tuned to ensure prolonged saturation. In summary, we have demonstrated that our combined in vitro experimental and mathematical modelling framework may be used to predict in vivo DES performance, opening up the possibility of an in silico approach to optimising the drug release profile and ultimately the effectiveness of the device.
Collapse
Affiliation(s)
- Craig M McKittrick
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Sean McKee
- Department of Mathematics & Statistics, University of Strathclyde, Glasgow, UK
| | - Simon Kennedy
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, UK
| | | | - Marcus Wheel
- Department of Mechanical & Aerospace Engineering, University of Strathclyde, Glasgow, UK
| | | | | | - Sean McGinty
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK.
| | | |
Collapse
|
14
|
Holland I, McCormick C, Connolly P. Towards non-invasive characterisation of coronary stent re-endothelialisation - An in-vitro, electrical impedance study. PLoS One 2018; 13:e0206758. [PMID: 30395632 PMCID: PMC6218196 DOI: 10.1371/journal.pone.0206758] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Accepted: 10/18/2018] [Indexed: 12/31/2022] Open
Abstract
The permanent implantation of a stent has become the most common method for ameliorating coronary artery narrowing arising from atherosclerosis. Following the procedure, optimal arterial wall healing is characterised by the complete regrowth of an Endothelial Cell monolayer over the exposed stent surface and surrounding tissue, thereby reducing the risk of thrombosis. However, excessive proliferation of Smooth Muscle Cells, within the artery wall can lead to unwanted renarrowing of the vessel lumen. Current imaging techniques are unable to adequately identify re-endothelialisation, and it has previously been reported that the stent itself could be used as an electrode in combination with electrical impedance spectroscopic techniques to monitor the post-stenting recovery phase. The utility of such a device will be determined by its ability to characterise between vascular cell types. Here we present in-vitro impedance spectroscopy measurements of pulmonary artery porcine Endothelial Cells, Human Umbilical Vein Endothelial Cells and coronary artery porcine Smooth Muscle Cells grown to confluence over platinum black electrodes in clinically relevant populations. These measurements were obtained, using a bespoke impedance spectroscopy system that autonomously performed impedance sweeps in the 1kHz to 100kHz frequency range. Analysis of the reactance component of impedance revealed distinct frequency dependent profiles for each cell type with post confluence reactance declines in Endothelial Cell populations that have not been previously reported. Such profiles provide a means of non-invasively characterising between the cell types and give an indication that impedance spectroscopic techniques may enable the non-invasive characterisation of the arterial response to stent placement.
Collapse
Affiliation(s)
- Ian Holland
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, Scotland, United Kingdom
- * E-mail:
| | - Christopher McCormick
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, Scotland, United Kingdom
| | - Patricia Connolly
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, Scotland, United Kingdom
| |
Collapse
|
15
|
Effect of Interstitial Fluid Flow on Drug-Coated Balloon Delivery in a Patient-Specific Arterial Vessel with Heterogeneous Tissue Composition: A Simulation Study. Cardiovasc Eng Technol 2018; 9:251-267. [PMID: 29508375 DOI: 10.1007/s13239-018-0345-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Accepted: 02/23/2018] [Indexed: 11/27/2022]
Abstract
Angioplasty with drug-coated balloons (DCBs) using excipients as drug carriers is emerging as a potentially viable strategy demonstrating clinical efficacy and proposing additional compliance for the treatment of obstructive vascular diseases. An attempt is made to develop an improved computational model where attention has been paid to the effect of interstitial flow, that is, plasma convection and internalization of bound drug. The present model is capable of capturing the phenomena of the transport of free drug and its retention, and also the internalization of drug in the process of endocytosis to atherosclerotic vessel of heterogeneous tissue composition comprising of healthy tissue, as well as regions of fibrous cap, fibro-fatty, calcified and necrotic core lesions. Image processing based on an unsupervised clustering technique is used for color-based segmentation of a patient-specific longitudinal image of atherosclerotic vessel obtained from intravascular ultrasound derived virtual histology. As the residence time of drug in a stent-based delivery within the arterial tissue is strongly influenced by convective forces, effect of interstitial fluid flow in case of DCB delivery can not be ruled out, and has been investigated by modeling it through unsteady Navier-Stokes equations. Transport of free drug is modeled by considering unsteady advection-reaction-diffusion process, while the bound drug, assuming completely immobilized in the tissue, by unsteady reaction process. The model also takes into account the internalization of drug through the process of endocytosis which gets degraded by the lysosomes and finally recycled into the extracellular fluid. All the governing equations representing the flow of interstitial fluid, the transport of free drug, the metabolization of free drug into bound phase and the process of internalization along with the physiologically realistic boundary and initial conditions are solved numerically using marker and cell method satisfying necessary stability criteria. Simulated results obtained predict that faster drug transfer promotes rapid saturation of binding sites despite perivascular wash out and the concentrations of all drug forms are modulated by the presence of interstitial flow. Such premier attempt of its kind would certainly be of great help in the optimization of therapeutic efficacy of drug.
Collapse
|
16
|
Mandal AP, Mandal PK. Distribution and retention of drug through an idealised atherosclerotic plaque eluted from a half-embedded stent. ACTA ACUST UNITED AC 2017. [DOI: 10.1007/s40435-017-0372-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
17
|
Bhise K, Kashaw SK, Sau S, Iyer AK. Nanostructured lipid carriers employing polyphenols as promising anticancer agents: Quality by design (QbD) approach. Int J Pharm 2017; 526:506-515. [PMID: 28502895 PMCID: PMC5577003 DOI: 10.1016/j.ijpharm.2017.04.078] [Citation(s) in RCA: 59] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2017] [Revised: 04/28/2017] [Accepted: 04/29/2017] [Indexed: 12/14/2022]
Abstract
Cancer is one of the leading causes of death worldwide. There are several hurdles in cancer therapy because of side-effects which limits its usage. Nanoparticulate drug delivery systems have been tested against cancer in a range of scientific studies. In the recent years, advanced research on Nanostructured Lipid Carriers (NLCs) has garnered considerable attention owing to the advantages over their first-generation counterparts, Solid Lipid Nanoparticles (SLN). NLCs facilitate efficient loading of poorly water soluble drugs with simple methods of drug loading. Recently, there is an increased interest in polyphenols because of the evidence of their promising role in prevention of cancer. Polyphenols are produced as secondary metabolites by plants. Their role in prevention of development of tumors through variety of mechanisms and reduction of tumor cell mass has been reported. This article aims to review the science behind development of NLCs and role of polyphenols as promising anticancer agents. Principles of Quality by Design (QbD) have also been explained which are used in formulation-development of many nanoparticles, including NLCs, as reported in literature.
Collapse
Affiliation(s)
- Ketki Bhise
- Use-inspired Biomaterials & Integrated Nano Delivery (U-BiND) Systems Laboratory, Department of Pharmaceutical Sciences, Wayne State University, Detroit, MI, USA
| | - Sushil Kumar Kashaw
- Use-inspired Biomaterials & Integrated Nano Delivery (U-BiND) Systems Laboratory, Department of Pharmaceutical Sciences, Wayne State University, Detroit, MI, USA; Department of Pharmaceutical Sciences, Dr. Harisingh Gour University (A Central University), Sagar, MP, India
| | - Samaresh Sau
- Use-inspired Biomaterials & Integrated Nano Delivery (U-BiND) Systems Laboratory, Department of Pharmaceutical Sciences, Wayne State University, Detroit, MI, USA
| | - Arun K Iyer
- Use-inspired Biomaterials & Integrated Nano Delivery (U-BiND) Systems Laboratory, Department of Pharmaceutical Sciences, Wayne State University, Detroit, MI, USA; Molecular Therapeutics Program, Barbara Ann Karmanos Cancer Institute, Wayne State University School of Medicine, Detroit, MI, USA.
| |
Collapse
|
18
|
Computational Model of Drug-Coated Balloon Delivery in a Patient-Specific Arterial Vessel with Heterogeneous Tissue Composition. Cardiovasc Eng Technol 2016; 7:406-419. [PMID: 27443840 DOI: 10.1007/s13239-016-0273-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Accepted: 07/06/2016] [Indexed: 01/23/2023]
Abstract
Balloon angioplasty followed by local delivery of antiproliferative drugs to target tissue is increasingly being considered for the treatment of obstructive arterial disease, and yet there is much to appreciate regarding pharmacokinetics in arteries of non-uniform disease. We developed a computational model capable of simulating drug-coated balloon delivery to arteries of heterogeneous tissue composition comprising healthy tissue, as well as regions of fibrous, fibro-fatty, calcified and necrotic core lesions. Image processing using an unsupervised clustering technique was used to reconstruct an arterial geometry from a single, patient-specific color image obtained from intravascular ultrasound-derived virtual histology. Transport of free drug was modeled using a time-dependent reaction-diffusion model and the bound, immobilized drug using the time-dependent reaction equation. The governing equations representing the transport of free as well as bound drug along with a set of initial settings and boundary conditions were solved numerically using an explicit finite difference scheme that satisfied the Courant-Friedrichs-Lewy stability criterion. Our results support previous findings related to the transport and binding of drug in arteries where tissue retention is strongly dependent on local pharmacologic properties. Additionally, modeling results indicate that non-uniform disease composition leads to heterogeneous arterial drug distribution patterns, although further validation using animal studies is required to fully appreciate pharmacokinetics in disease-laden arteries.
Collapse
|
19
|
Towards the development of an in vitro model of atherosclerotic peripheral vessels for evaluating drug-coated endovascular technologies. Drug Discov Today 2016; 21:1512-1520. [PMID: 27297733 DOI: 10.1016/j.drudis.2016.05.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 04/27/2016] [Accepted: 05/27/2016] [Indexed: 11/20/2022]
Abstract
Here, we review the in vitro models used to evaluate drug-coated endovascular technologies. The models are assessed in the context of representing the drug transport/uptake and mechanical properties of atherosclerotic peripheral vessels. Studies to date have incorporated a vessel-simulating hydrogel compartment to examine drug elution from endovascular devices. However, comparisons between in vitro models and atherosclerotic tissue are difficult because ex vivo data are limited in their applicability to diseased peripheral vessels. Furthermore, appropriate ex vivo mechanical properties are not incorporated into these models. Therefore, there is a need to characterise the drug transport/uptake properties of appropriate atherosclerotic tissue and incorporate existing ex vivo mechanical data into current in vitro models to more accurately represent drug behaviour in atherosclerotic peripheral vessels.
Collapse
|