Qi B, Fu L, Abdelrehim T, Chang JJ, Chang H, Chen C, Jokerst JV. Ultrasound identification of the cementoenamel junction and clinical correlation through ex vivo analysis. Sci Rep 2024; 14:27821. [PMID: 39537843 PMCID: PMC11561095 DOI: 10.1038/s41598-024-79081-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Accepted: 11/06/2024] [Indexed: 11/16/2024] Open
Abstract
Accurately identifying periodontal landmarks via acoustic imaging is increasingly important. Here, we evaluated the accuracy of cementoenamel junction (CEJ) identification using ultrasound by comparing it to clinical methods in 153 extracted human teeth. The distance between the CEJ to a reference point was measured using two clinical methods (visual examination and tactile sensation) as well as ultrasound imaging. Statistical analyses were performed across all teeth and sub-groups, including tooth types (incisors, cuspids, and molars/premolars), and two classifications: A- vs. B- (visually detectable or undetectable CEJ, respectively); and CL-S vs. CL-D (shallow or deep cervical lesions). In A- or CL-S teeth, ultrasound measurements highly agreed with clinical measurements, showing a 1.72-mm 95% CI for A- and 1.99-mm 95% CI for CL-S compared to visual examination, and a 1.77-mm 95% CI for A- and a 2.10-mm 95% CI for CL-S compared to tactile sensation, respectively. For 80% of A- and 76% of CL-S teeth, the difference between ultrasound and visual examination was within ± 20%. For 81% of A- and 80% of CL-S teeth, the difference between ultrasound and tactile sensation was within ± 20%. The variance of ultrasound versus clinical CEJ identifications showed a significant correlation (r = 0.6607) to the cervical lesion depth. The errors between ultrasound and clinical measurements show no significant bias across different tooth types.
Collapse
Affiliation(s)
- Baiyan Qi
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Lei Fu
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Tamer Abdelrehim
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, 92093, USA
| | - Jason J Chang
- Herman Ostrow School of Dentistry, University of Southern California, 925 West 34th Street, Los Angeles, CA, USA
| | - Harrison Chang
- Herman Ostrow School of Dentistry, University of Southern California, 925 West 34th Street, Los Angeles, CA, USA
| | - Casey Chen
- Herman Ostrow School of Dentistry, University of Southern California, 925 West 34th Street, Los Angeles, CA, USA
| | - Jesse V Jokerst
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, 92093, USA.
- Material Science and Engineering Program, University of California, San Diego, La Jolla, CA, 92093, USA.
- Radiology Department, University of California, San Diego, La Jolla, CA, 92093, USA.
| |
Collapse
|
2
|
Kumaralingam L, Dinh HBV, Nguyen KCT, Punithakumar K, La TG, Lou EHM, Major PW, Le LH. DetSegDiff: A joint periodontal landmark detection and segmentation in intraoral ultrasound using edge-enhanced diffusion-based network. Comput Biol Med 2024; 182:109174. [PMID: 39321583 DOI: 10.1016/j.compbiomed.2024.109174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Revised: 08/04/2024] [Accepted: 09/17/2024] [Indexed: 09/27/2024]
Abstract
Individuals with malocclusion require an orthodontic diagnosis and treatment plan based on the severity of their condition. Assessing and monitoring changes in periodontal structures before, during, and after orthodontic procedures is crucial, and intraoral ultrasound (US) imaging has been shown a promising diagnostic tool in imaging periodontium. However, accurately delineating and analyzing periodontal structures in US videos is a challenging task for clinicians, as it is time-consuming and subject to interpretation errors. This paper introduces DetSegDiff, an edge-enhanced diffusion-based network developed to simultaneously detect the cementoenamel junction (CEJ) and segment alveolar bone structure in intraoral US videos. An edge feature encoder is designed to enhance edge and texture information for precise delineation of periodontal structures. Additionally, we employed the spatial squeeze-attention module (SSAM) to extract more representative features to perform both detection and segmentation tasks at global and local levels. This study used 169 videos from 17 orthodontic patients for training purposes and was subsequently tested on 41 videos from 4 additional patients. The proposed method achieved a mean distance difference of 0.17 ± 0.19 mm for the CEJ and an average Dice score of 90.1% for alveolar bone structure. As there is a lack of multi-task benchmark networks, thorough experiments were undertaken to assess and benchmark the proposed method against state-of-the-art (SOTA) detection and segmentation individual networks. The experimental results demonstrated that DetSegDiff outperformed SOTA approaches, confirming the feasibility of using automated diagnostic systems for orthodontists.
Collapse
Affiliation(s)
- Logiraj Kumaralingam
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, T6G 2R7, Canada
| | - Hoang B V Dinh
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, T6G 2R7, Canada
| | - Kim-Cuong T Nguyen
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, T6G 2R7, Canada
| | - Kumaradevan Punithakumar
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, T6G 2R7, Canada
| | - Thanh-Giang La
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, T6G 2R7, Canada
| | - Edmond H M Lou
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, T6G 2V2, Canada; Department of Electrical Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada
| | - Paul W Major
- School of Dentistry, University of Alberta, Edmonton, Alberta, T6G 1C9, Canada
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, T6G 2R7, Canada; Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, T6G 2V2, Canada; School of Dentistry, University of Alberta, Edmonton, Alberta, T6G 1C9, Canada; Department of Physics, University of Alberta, Edmonton, Alberta, T6G 2E1, Canada.
| |
Collapse
|
3
|
Le LH, Nguyen KCT, La TG, Nguyen VD, Le MB, Kumaradevan P, Kaipatur N, Major PW, Lou EHM. Intraoral Ultrasound Imaging Using a Rotational Transducer with Periodontal Feature Identification by Machine Learning. ACS Sens 2024; 9:3898-3906. [PMID: 39175386 DOI: 10.1021/acssensors.4c00124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2024]
Abstract
Innovative intraoral ultrasound devices with smart artificial intelligence-based identification for dento-anatomy could provide crucial information for oral health diagnosis and treatment and shed light on real-time detection of developmental dentistry. However, the grand challenge is that the current ultrasound technologies are meant for external use due to their bulkiness and low frequency. We report a compact versatile ultrasound intraoral device that consists of a rotational probe head robustly pivoted around a hand-held and portable handle for real-time imaging of intraoral anatomy using high-frequency ultrasonography (up to 25 MHz). The intraoral ultrasound device that could be adjusted for various orientations of the imaging planes by rotating the head provides real-time, high-resolution ultrasonograms of intraoral structures, including dento-periodontium of most tooth types and maxillary palate. Machine learning-based algorithms are integrated to automate the identification of important structures, including alveolar bone and cementum-enamel junction. The intraoral ultrasound device smartened with artificial intelligence could innovate oral health diagnosis and treatment plans toward precision health and patient care.
Collapse
Affiliation(s)
- Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada T6G 2R7
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada T6G 2 V2
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada T6G 1C9
- Department of Physics, University of Alberta, Edmonton, Alberta, Canada T6G 2E1
| | - Kim-Cuong T Nguyen
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada T6G 2R7
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada T6G 2 V2
| | - Thanh-Giang La
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada T6G 2R7
| | - Vu Duc Nguyen
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada T6G 2R7
| | - Minh Binh Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada T6G 2R7
| | - Punithakumar Kumaradevan
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada T6G 2R7
| | - Neelambar Kaipatur
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada T6G 1C9
| | - Paul W Major
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada T6G 1C9
| | - Edmond H M Lou
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada T6G 2 V2
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, Canada T6G 1H9
| |
Collapse
|
4
|
Yeung AWK, AlHadidi A, Vyas R, Bornstein MM, Watanabe H, Tanaka R. Nonionizing diagnostic imaging modalities for visualizing health and pathology of periodontal and peri-implant tissues. Periodontol 2000 2024; 95:87-101. [PMID: 38951932 DOI: 10.1111/prd.12591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 05/20/2024] [Accepted: 06/17/2024] [Indexed: 07/03/2024]
Abstract
Radiographic examination has been an essential part of the diagnostic workflow in periodontology and implant dentistry. However, radiographic examination unavoidably involves ionizing radiation and its associated risks. Clinicians and researchers have invested considerable efforts in assessing the feasibility and capability of utilizing nonionizing imaging modalities to replace traditional radiographic imaging. Two such modalities have been extensively evaluated in clinical settings, namely, ultrasonography (USG) and magnetic resonance imaging (MRI). Another modality, optical coherence tomography (OCT), has been under investigation more recently. This review aims to provide an overview of the literature and summarize the usage of USG, MRI, and OCT in evaluating health and pathology of periodontal and peri-implant tissues. Clinical studies have shown that USG could accurately measure gingival height and crestal bone level, and classify furcation involvement. Due to physical constraints, USG may be more applicable to the buccal surfaces of the dentition even with an intra-oral probe. Clinical studies have also shown that MRI could visualize the degree of soft-tissue inflammation and osseous edema, the extent of bone loss at furcation involvement sites, and periodontal bone level. However, there was a lack of clinical studies on the evaluation of peri-implant tissues by MRI. Moreover, an MRI machine is very expensive, occupies much space, and requires more time than cone-beam computed tomography (CBCT) or intraoral radiographs to complete a scan. The feasibility of OCT to evaluate periodontal and peri-implant tissues remains to be elucidated, as there are only preclinical studies at the moment. A major shortcoming of OCT is that it may not reach the bottom of the periodontal pocket, particularly for inflammatory conditions, due to the absorption of near-infrared light by hemoglobin. Until future technological breakthroughs finally overcome the limitations of USG, MRI and OCT, the practical imaging modalities for routine diagnostics of periodontal and peri-implant tissues remain to be plain radiographs and CBCTs.
Collapse
Affiliation(s)
- Andy Wai Kan Yeung
- Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China
| | - Abeer AlHadidi
- Oral and Maxillofacial Pathology, Radiology and Medicine, New York University, New York, New York, USA
| | - Rutvi Vyas
- University of Detroit Mercy School of Dentistry, Detroit, Michigan, USA
| | - Michael M Bornstein
- Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Hiroshi Watanabe
- Dental Radiology and Radiation Oncology, Department of Oral Restitution, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan
| | - Ray Tanaka
- Oral and Maxillofacial Radiology, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, China
| |
Collapse
|
5
|
Hoang TH, Nguyen KCT, Kaipatur NR, Alexiou M, La TG, Lagravère Vich MO, Major PW, Punithakumar K, Lou EH, Le LH. Ultrasonic mapping of midpalatal suture - An ex-vivo study. J Dent 2024; 145:105024. [PMID: 38670332 DOI: 10.1016/j.jdent.2024.105024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 04/05/2024] [Accepted: 04/24/2024] [Indexed: 04/28/2024] Open
Abstract
OBJECTIVE Rapid maxillary expansion is a common orthodontic procedure to correct maxillary constriction. Assessing the midpalatal suture (MPS) expansion plays a crucial role in treatment planning to determine its effectiveness. The objectives of this preliminary investigation are to demonstrate a proof of concept that the palatal bone underlying the rugae can be clearly imaged by ultrasound (US) and the reconstructed axial view of the US image accurately maps the MPS patency. METHODS An ex-vivo US scanning was conducted on the upper jawbones of two piglet's carcasses before and after the creation of bone defects, which simulated the suture opening. The planar images were processed to enhance bone intensity distribution before being orderly stacked to fuse into a volume. Graph-cut segmentation was applied to delineate the palatal bone to generate a bone volume. The accuracy of the reconstructed bone volume and the suture opening was validated by the micro-computed tomography (µCT) data used as the ground truth and compared with cone beam computed tomography (CBCT) data as the clinical standard. Also included in the comparison is the rugae thickness. Correlation and Bland-Altman plots were used to test the agreement between the two methods: US versus µCT/CBCT. RESULTS The reconstruction of the US palatal bone volumes was accurate based on surface topography comparison with a mean error of 0.19 mm for pre-defect and 0.15 mm and 0.09 mm for post-defect models of the two samples, respectively when compared with µCT volumes. A strong correlation (R2 ≥ 0.99) in measuring MPS expansion was found between US and µCT/CBCT with MADs of less than 0.05 mm, 0.11 mm and 0.23 mm for US, µCT and CBCT, respectively. CONCLUSIONS It was possible to axially image the MPS opening and rugae thickness accurately using high-frequency ultrasound. CLINICAL SIGNIFICANCE This study introduces an ionizing radiation-free, low-cost, and portable technique to accurately image a difficult part of oral cavity anatomy. The advantages of conceivable visualization could promise a successful clinical examination of MPS to support the predictable treatment outcome of maxillary transverse deficiency.
Collapse
Affiliation(s)
- Trang H Hoang
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada
| | - Kim-Cuong T Nguyen
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada
| | | | - Maria Alexiou
- School of Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Thanh-Giang La
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada
| | | | - Paul W Major
- School of Dentistry, University of Alberta, Edmonton, AB, Canada
| | | | - Edmond H Lou
- Department of Electrical and Computing Engineering, University of Alberta, Edmonton, AB, Canada; Department of Biomedical Engineering, University of Alberta, Edmonton, AB, Canada
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada; School of Dentistry, University of Alberta, Edmonton, AB, Canada; Department of Biomedical Engineering, University of Alberta, Edmonton, AB, Canada; Department of Physics, University of Alberta, Edmonton, AB, Canada.
| |
Collapse
|
6
|
Torumtay Cin G, Lektemur Alpan A, Açikgöz G, Özlü Uçan G. Ultrasonographic analysis of palatal donor site healing accelerated with platelet-rich fibrin following subepithelial connective tissue harvesting. J Appl Oral Sci 2024; 32:e20230448. [PMID: 38655988 DOI: 10.1590/1678-7757-2023-0448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 02/21/2024] [Indexed: 04/26/2024] Open
Abstract
OBJECTIVE Platelet-rich fibrin (PRF) contains a variety of growth factors and bioactive molecules that play crucial roles in wound healing and angiogenesis. We aimed to evaluate the effects of PRF on tissue thickness and vascularization of the palatal donor site by ultrasound (USG) following subepithelial connective tissue harvesting. METHODOLOGY A subepithelial connective tissue graft was harvested from the palatal region with a single incision for root coverage in 20 systemically healthy patients. In the test group (n = 10), the PRF membrane was placed at the donor site, whereas no material was applied in the control group (n=10). Palatal tissue thickness (PTT) and pulsatility index (PI) were evaluated by USG at baseline and on the 3rd, 7th, 14th, 30th, and 90th days after surgery. The early healing index (EHI) was used to evaluate donor site healing for 30 days. RESULTS PTT was significantly higher in the PRF group on the 3rd and 14th days after surgery when compared to the controls. In the PRF-treated group, PI levels were significantly higher than in the controls, especially on the 14th day. PTT increased significantly 90 days after surgery compared to the test group baseline, but controls showed a significant decrease. The PRF group showed statistically significant improvements in EHI scores compared to controls on days 3, 7, and 14. This study found a negative correlation between PI values and EHI scores on postoperative days three and seven in the test group. CONCLUSION USG is a non-invasive, objective method to radiographically evaluate the regenerative effects of PRF on palatal wound healing after soft tissue harvesting. To overcome graft inadequacy in reharvesting procedures, PRF application may enhance clinical success and reduce possible complications by increasing tissue thickness and revascularization in the donor area.
Collapse
Affiliation(s)
- Gizem Torumtay Cin
- Pamukkale University, Faculty of Dentistry, Department of Periodontology, Denizli, Turkey
| | - Aysan Lektemur Alpan
- Pamukkale University, Faculty of Dentistry, Department of Periodontology, Denizli, Turkey
| | - Gözde Açikgöz
- Pamukkale University, Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Denizli, Turkey
| | - Gülfem Özlü Uçan
- Gelişim University, Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, İstanbul, Turkey
| |
Collapse
|
7
|
Figueredo CA, Lai H, Gibson MP, Le LH, Almeida FT, Major PW. The repeatability of periodontal imaging with intraoral ultrasound scanning. Clin Oral Investig 2024; 28:164. [PMID: 38383689 DOI: 10.1007/s00784-024-05564-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 02/16/2024] [Indexed: 02/23/2024]
Abstract
OBJECTIVE Ultrasound is a non-invasive and low-cost diagnostic tool widely used in medicine. Recent studies have demonstrated that ultrasound imaging might have the potential to be used intraorally to assess the periodontium by comparing it to current imaging methods. This study aims to characterize the repeatability of intraoral periodontal ultrasound imaging. MATERIALS AND METHODS Two hundred and twenty-three teeth were scanned from fourteen volunteers participating in this study. One operator conducted all the scans in each tooth thrice with a 20 MHz intraoral ultrasound. The repeatability of three measurements, alveolar bone crest to the cementoenamel junction (ABC-CEJ), gingival thickness (GT), and alveolar bone thickness (ABT), was calculated with intercorrelation coefficient (ICC). Measurements were also compared with mean absolute deviation (MAD), repeatability coefficient (RC), and descriptive statistics. RESULTS ICC scores for intra-rater repeatability were 0.917(0.897,0.933), 0.849(0.816,0.878), and 0.790(0.746,0.898), MAD results were 0.610 mm (± 0.508), 0.224 (± 0.200), and 0.067 (± 0.060), and RC results were 0.648, 0.327, and 0.121 for ABC-CEJ, GT, and ABT measurements, respectively. CONCLUSION Results of the present study pointed towards good or excellent repeatability of ultrasound as a measurement tool for periodontal structures. CLINICAL RELEVANCE Clinicians could benefit from the introduction of a novel chairside diagnostic tool. Ultrasound is a non-invasive imaging assessment tool for the periodontium with promising results in the literature. Further validation, establishment of scanning protocols, and commercialization are still needed before ultrasound imaging is available for clinicians.
Collapse
Affiliation(s)
- Carlos Alberto Figueredo
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada.
| | - Hollis Lai
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Monica P Gibson
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
- School of Dentistry, Indiana University, Indianapolis, IN, United States
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada
| | - Fabiana T Almeida
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Paul W Major
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
8
|
Figueredo CA, Catunda RQ, Gibson MP, Major PW, Almeida FT. Use of ultrasound imaging for assessment of the periodontium: A systematic review. J Periodontal Res 2024; 59:3-17. [PMID: 37872805 DOI: 10.1111/jre.13194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 09/25/2023] [Accepted: 10/01/2023] [Indexed: 10/25/2023]
Abstract
The objective of this study was to systematically review the literature regarding diagnostic applications of ultrasound imaging for evaluation of the periodontium in humans. The search was conducted on Medline, EMBASE, Web of Science, Scopus, Cochrane, and PubMed up to April 3, 2023. The studies included were exclusively human studies that assessed the periodontium with ultrasound (US) imaging (b-mode). Outcomes measured included alveolar bone level, alveolar bone thickness, gingival thickness, and blood flow quantification. References were imported to Covidence. Two reviewers conducted phases 1 and 2. The JBI risk assessment tool for cross-sectional studies was used. Extracted data included the transducer and measurements used and the study's outcomes. The search yielded 4892 studies after removing duplicates. From these, 25 studies were included and selected for extraction. Included studies retrieved outcomes from US examinations of the periodontal tissues. From the selected studies, 15 used US on natural teeth, 4 used US on implants, 2 used US on edentulous ridges, and 4 used color flow/power in US to evaluate the blood flow. The results of the present systematic review suggest that US might be a feasible and valuable diagnostic tool for the periodontium, with the potential to complement shortfalls of current radiographic technologies.
Collapse
Affiliation(s)
- Carlos Alberto Figueredo
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Raisa Queiroz Catunda
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Monica P Gibson
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Paul W Major
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Fabiana T Almeida
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
9
|
Nguyen KCT, Le LH, Kaipatur NR, Almeida FT, Lai H, Lou EHM, Major PW. Measuring the alveolar bone level in adolescents: A comparison between ultrasound and cone beam computed tomography. Int J Paediatr Dent 2023; 33:487-497. [PMID: 37386727 DOI: 10.1111/ipd.13092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 06/05/2023] [Accepted: 06/07/2023] [Indexed: 07/01/2023]
Abstract
BACKGROUND Cone beam computed tomography (CBCT) is an imaging modality, which is used routinely in orthodontic diagnosis and treatment planning but delivers much higher radiation than conventional dental radiographs. Ultrasound is a noninvasive imaging method that creates an image without ionizing radiation. AIM To investigate the reliability of ultrasound and the agreement between ultrasound and CBCT in measuring the alveolar bone level (ABL) on the buccal/labial side of the incisors in adolescent orthodontic patients. DESIGN One hundred and eighteen incisors from 30 orthodontic adolescent patients were scanned by CBCT with 0.3-mm voxel size and ultrasound at 20 MHz frequency. The ABL, distance from the cementoenamel junction (CEJ) to the alveolar bone crest (ABC), was measured twice to evaluate the agreement between ultrasound and CBCT. In addition, the intra- and inter-rater reliabilities in measuring the ABL by four raters were compared. RESULTS The mean difference (MD) in the ABL between ultrasound and CBCT was -0.07 mm with 95% limit of agreement (LoA) from -0.47 to 0.32 mm for all teeth. For each jaw, the MDs between the ultrasound and CBCT were -0.18 mm (for mandible with 95% LoA from -0.53 to 0.18 mm) and 0.03 mm (for maxilla with 95% LoA from -0.28 to 0.35 mm). In comparison, ultrasound had higher intra-rater (ICC = 0.83-0.90) and inter-rater reliabilities (ICC = 0.97) in ABL measurement than CBCT (ICC = 0.56-0.78 for intra-rater and ICC = 0.69 for inter-rater reliabilities). CONCLUSION CBCT parameters used in orthodontic diagnosis and treatment planning in adolescents may not be a reliable tool to assess the ABL for the mandibular incisors. On the contrary, ultrasound imaging, an ionizing radiation-free, inexpensive, and portable diagnostic tool, has potential to be a reliable diagnostic tool in assessing the ABL in adolescent patients.
Collapse
Affiliation(s)
- Kim-Cuong T Nguyen
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | | | - Fabiana T Almeida
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Hollis Lai
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Edmond H M Lou
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Paul W Major
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
10
|
Le LH, Nguyen KCT, Nguyen PTT, La TG, Major PW, Lou EHM. Estimating Crestal Thickness of Alveolar Bones on Intra-oral Ultrasonograms. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1345-1350. [PMID: 36813583 DOI: 10.1016/j.ultrasmedbio.2023.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 01/13/2023] [Accepted: 01/14/2023] [Indexed: 05/10/2023]
Abstract
OBJECTIVE Alveolar crestal bone thickness and level provide important diagnostic and prognostic information for orthodontic treatment, periodontal disease management and dental implants. Ionizing radiation-free ultrasound has emerged as a promising clinical tool in imaging oral tissues. However, the ultrasound image is distorted when the wave speed of the tissue of interest is different from the mapping speed of the scanner and, therefore, the subsequent dimension measurements are not accurate. This study was aimed at deriving a correction factor that can be applied to the measurements to correct for discrepancy caused by speed variation. METHODS The factor is a function of the speed ratio and the acute angle that the segment of interest makes with the beam axis perpendicular to the transducer. The phantom and cadaver experiments were designed to validate the method. DISCUSSION The comparisons agree well with absolute errors not more than 4.9%. Dimension measurements on ultrasonographs can be properly corrected by applying the correction factor without recourse to the raw signals. CONCLUSION The correction factor has reduced the measurement discrepancy on the acquired ultrasonographs for the tissue whose speed is different from the scanner's mapping speed.
Collapse
Affiliation(s)
- Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada; Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada; Department of Physics, University of Alberta, Edmonton, Alberta, Canada; School of Dentistry, University of Alberta, Edmonton, Alberta, Canada.
| | - Kim-Cuong T Nguyen
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada; Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | | | - Thanh-Giang La
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| | - Paul W Major
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Edmond H M Lou
- Department of Electrical Engineering, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
11
|
Figueredo CA, Le LH, Nguyen KC, La TG, Lou EHM, Kaipatur NR, Lai H, Gibson MP, Flores-Mir C, Major PW, Almeida FT. Ultrasound Imaging of the Periodontium Complex: A Reliability Study. Int J Dent 2023; 2023:5494429. [PMID: 36845629 PMCID: PMC9949946 DOI: 10.1155/2023/5494429] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 01/25/2023] [Accepted: 01/30/2023] [Indexed: 02/18/2023] Open
Abstract
Background Ultrasonography is a noninvasive, low-cost diagnostic tool widely used in medicine. Recent studies have demonstrated that ultrasound imaging might have the potential to be used intraorally to assess periodontal biomarkers. Objectives To evaluate the reliability of interlandmark distance measurements on intraoral ultrasound images of the periodontal tissues. Materials and Methods Sixty-four patients from the graduate periodontics (n = 33) and orthodontics (n = 31) clinics were recruited. A 20 MHz handheld intraoral ultrasound transducer was used to scan maxillary and mandibular incisors, canines, and premolars. Distances between the alveolar bone crest and cementoenamel junction (ABC-CEJ), gingival thickness (GT), and alveolar bone thickness (ABT) were measured by 3 raters. The intercorrelation coefficient (ICC) and mean absolute deviation (MAD) were calculated among and between the raters. Raters also scored images according to quality. Results The ICC scores for intrarater reliability were 0.940 (0.932-0.947), 0.953 (0.945-0.961), and 0.859 (0.841-0.876) for ABC-CEJ, GT, and ABT, respectively. The intrarater MAD values were 0.023 (±0.019) mm, 0.014 (±0.005) mm, and 0.005 (±0.003) mm, respectively. The ICC scores for interrater reliability were 0.872 (95% CI: 0.836-0.901), 0.958 (95% CI: 0.946-0.968), and 0.836 (95% CI: 0.789-0.873) for ABC-CEJ, GT, and ABT, respectively. The interrater MAD values were 0.063 (±0.029) mm, 0.023 (±0.018) mm, and 0.027 (±0.012) mm, respectively. Conclusions The present study showed the high reliability of ultrasound in both intrarater and interrater assessments. Results suggest there might be a potential use of intraoral ultrasound to assess periodontium.
Collapse
Affiliation(s)
- Carlos Alberto Figueredo
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Lawrence H. Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada
| | - Kim Cuong Nguyen
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada
- Department of Biomedical Engineering, University of Alberta, Edmonton, AB, Canada
| | - Thanh-Giang La
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada
| | - Edmond H. M. Lou
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada
| | - Neelambar R. Kaipatur
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Hollis Lai
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Monica P. Gibson
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Carlos Flores-Mir
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Paul W. Major
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| | - Fabiana T. Almeida
- School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
12
|
Intraoral Ultrasonography for Periodontal Tissue Exploration: A Review. Diagnostics (Basel) 2023; 13:diagnostics13030365. [PMID: 36766470 PMCID: PMC9914868 DOI: 10.3390/diagnostics13030365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/09/2023] [Accepted: 01/16/2023] [Indexed: 01/21/2023] Open
Abstract
This systematic review aims to investigate the possibilities of ultrasound imaging in the field of periodontal tissues exploration to visualize periodontal anatomical structures and to assess reliability in clinical evaluation using the PRISMA guidelines. An electronic search through the MEDLINE database was realized to identify studies that have explored ultrasonography in the field of periodontal imaging published from 2000 to March 2022. The search resulted in 245 records; after exclusions, a total of 15 papers were included in the present review. Various publications have shown the possibility of using intraoral ultrasound for a precise exploration of intraoral tissues and to perform measurements of periodontal structures. Studies argue that ultrasounds open the prospect of a complete paradigm shift on the diagnosis and follow-up of periodontal disease. However, there is currently no clinical device dedicated to periodontal ultrasound. This field is still under-studied, and studies are needed to explore the large field of applications from periodontal assessment to treatment reassessment, including surgery. Researchers should focus their efforts to develop special intraoral ultrasound device and explore the possibilities of clinical periodontal applications.
Collapse
|
13
|
Fu L, Khazaeinezhad R, Hariri A, Qi B, Chen C, Jokerst JV. Posterior photoacoustic/ultrasound imaging of the periodontal pocket with a compact intraoral transducer. PHOTOACOUSTICS 2022; 28:100408. [PMID: 36204181 PMCID: PMC9530592 DOI: 10.1016/j.pacs.2022.100408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 08/15/2022] [Accepted: 09/25/2022] [Indexed: 06/16/2023]
Abstract
Periodontitis is a public issue and imaging periodontal pocket is important to evaluate periodontitis. Regular linear transducers have limitations in imaging the posterior teeth due to their geometry restrictions. Here we characterized a transducer that can image the posterior teeth including assessment of periodontal pockets via a combination of photoacoustic and ultrasound imaging. Unlike conventional transducer design, this device has a toothbrush-shaped form factor with a side-view transducer to image molars (total size: 1 ×1.9 cm). A laser diode was integrated as the light source to reduce the cost and size and facilitates clinical transition. The in vivo imaging of a molar of a periodontal patient demonstrated that the transducer could image in the posterior area of gum in vivo; the value determined by imaging was within 7 % of the value measured clinically.
Collapse
Affiliation(s)
- Lei Fu
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
| | | | - Ali Hariri
- StyloSonic LLC, Lake Forest, CA 92630, USA
| | - Baiyan Qi
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA 92093, USA
| | - Casey Chen
- Herman Ostrow School of Dentistry, University of Southern California, 925 West 34th Street, Los Angeles, CA 90089, USA
| | - Jesse V. Jokerst
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
- StyloSonic LLC, Lake Forest, CA 92630, USA
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA 92093, USA
- Department of Radiology, University of California San Diego, La Jolla, CA 92093, USA
| |
Collapse
|
14
|
Chifor R, Hotoleanu M, Marita T, Arsenescu T, Socaciu MA, Badea IC, Chifor I. Automatic Segmentation of Periodontal Tissue Ultrasound Images with Artificial Intelligence: A Novel Method for Improving Dataset Quality. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22197101. [PMID: 36236200 PMCID: PMC9572264 DOI: 10.3390/s22197101] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/16/2022] [Accepted: 09/16/2022] [Indexed: 05/28/2023]
Abstract
UNLABELLED This research aimed to evaluate Mask R-CNN and U-Net convolutional neural network models for pixel-level classification in order to perform the automatic segmentation of bi-dimensional images of US dental arches, identifying anatomical elements required for periodontal diagnosis. A secondary aim was to evaluate the efficiency of a correction method of the ground truth masks segmented by an operator, for improving the quality of the datasets used for training the neural network models, by 3D ultrasound reconstructions of the examined periodontal tissue. METHODS Ultrasound periodontal investigations were performed for 52 teeth of 11 patients using a 3D ultrasound scanner prototype. The original ultrasound images were segmented by a low experienced operator using region growing-based segmentation algorithms. Three-dimensional ultrasound reconstructions were used for the quality check and correction of the segmentation. Mask R-CNN and U-NET were trained and used for prediction of periodontal tissue's elements identification. RESULTS The average Intersection over Union ranged between 10% for the periodontal pocket and 75.6% for gingiva. Even though the original dataset contained 3417 images from 11 patients, and the corrected dataset only 2135 images from 5 patients, the prediction's accuracy is significantly better for the models trained with the corrected dataset. CONCLUSIONS The proposed quality check and correction method by evaluating in the 3D space the operator's ground truth segmentation had a positive impact on the quality of the datasets demonstrated through higher IoU after retraining the models using the corrected dataset.
Collapse
Affiliation(s)
- Radu Chifor
- Department of Preventive Dentistry, University of Medicine and Pharmacy Iuliu Hatieganu, 400083 Cluj-Napoca, Romania
- Chifor Research SRL, 400068 Cluj-Napoca, Romania
| | - Mircea Hotoleanu
- Romanian Institute of Science and Technology, 400022 Cluj-Napoca, Romania
| | - Tiberiu Marita
- Computer Science Department, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania
| | | | - Mihai Adrian Socaciu
- Department of Radiology and Imaging, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400162 Cluj-Napoca, Romania
| | - Iulia Clara Badea
- Department of Preventive Dentistry, University of Medicine and Pharmacy Iuliu Hatieganu, 400083 Cluj-Napoca, Romania
| | - Ioana Chifor
- Department of Preventive Dentistry, University of Medicine and Pharmacy Iuliu Hatieganu, 400083 Cluj-Napoca, Romania
| |
Collapse
|
15
|
Assessment of Negative Gingival Recession: A Critical Component of Periodontal Diagnosis. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12147015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Accurate measurement of negative gingival recession (GR) is essential to accurately determine the clinical attachment loss, which leads to an accurate diagnosis and optimal therapy of periodontal disease. However, the accuracy of measuring the negative GR has been shown to be low and highly variable between examiners. The position of the gingiva margin in relation to the cemento-enamel junction (CEJ) varies among different stages of passive eruption. The amount of negative GR is about 2 mm on average at the mid-facial sites and ranges from 2 to 3.5 mm at interproximal sites in periodontally healthy patients. Some other clinical conditions may change the gingival dimension coronal to the CEJ, such as altered passive eruption and gingival enlargement. In addition to the traditional approach using a periodontal probe to assess the negative GR, nowadays dental ultrasound imaging may be able to assist in accurately measuring the amount of negative GR. This narrative review will discuss the existing evidence of the dimension of dentogingival tissue and the clinical assessment of negative GR using different clinical tools.
Collapse
|
16
|
Fu L, Ling C, Jin Z, Luo J, Palma-Chavez J, Wu Z, Zhou J, Zhou J, Donovan B, Qi B, Mishra A, He T, Jokerst JV. Photoacoustic imaging of posterior periodontal pocket using a commercial hockey-stick transducer. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-210363GR. [PMID: 35610752 PMCID: PMC9128833 DOI: 10.1117/1.jbo.27.5.056005] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 05/02/2022] [Indexed: 06/02/2023]
Abstract
SIGNIFICANCE Photoacoustic imaging has shown advantages over the periodontal probing method in measuring the periodontal probing depth, but the large size of conventional photoacoustic transducers prevents imaging of the more posterior teeth. AIM Our aim is to develop a photoacoustic imaging system to image the more posterior periodontal pocket. APPROACH We report a clinical "hockey-stick"-style transducer integrated with fibers for periodontal photoacoustic imaging. Cuttlefish ink labeled the periodontal pocket as the photoacoustic contrast agent. RESULTS We characterized the imaging system and then measured the pocket depth of 35 swine teeth. Three raters evaluated the performance of the hockey-stick transducer. The measurements between the Williams probing (gold standard) and the photoacoustic methods were blinded but highly correlated. We showed a bias of ∼0.3 mm for the imaging-based technique versus Williams probing. The minimum inter-reliability was over 0.60 for three different raters of varying experience, suggesting that this approach to measure the periodontal pocket is reproducible. Finally, we imaged three pre-molars of a human subject. We could access more upper and posterior teeth than conventional linear transducers. CONCLUSIONS The unique angle shape of the hockey-stick transducer allows it to image more posterior teeth than regular linear transducers. This study demonstrated the ability of a hockey-stick transducer to measure the periodontal pocket via photoacoustic imaging.
Collapse
Affiliation(s)
- Lei Fu
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Chen Ling
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Zhicheng Jin
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Jessica Luo
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Jorge Palma-Chavez
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Zhuohong Wu
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Jingcheng Zhou
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Jiajing Zhou
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Brian Donovan
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - Baiyan Qi
- University of California San Diego, Materials Science and Engineering Program, La Jolla, California, United States
| | - Aditya Mishra
- University of California San Diego, Materials Science and Engineering Program, La Jolla, California, United States
| | - Tengyu He
- University of California San Diego, Materials Science and Engineering Program, La Jolla, California, United States
| | - Jesse V. Jokerst
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
- University of California San Diego, Materials Science and Engineering Program, La Jolla, California, United States
- University of California San Diego, Department of Radiology, La Jolla, California, United States
| |
Collapse
|
17
|
Ultrasound Imaging in Dentistry: A Literature Overview. J Imaging 2021; 7:jimaging7110238. [PMID: 34821869 PMCID: PMC8624259 DOI: 10.3390/jimaging7110238] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 11/07/2021] [Accepted: 11/12/2021] [Indexed: 12/26/2022] Open
Abstract
(1) Background: the frequency with which diagnostic tests are prescribed with exposure to ionizing radiation, a cause of biological damage, has been studied, and with much more attention, patients are subjected to these diagnostic tests for diagnosis and follow-up. This review aimed, given the recent developments of this technology, to evaluate the possible use of ultrasound in different branches of dentistry. The possibility of applying ionizing-radiation-free diagnostic exams in dentistry, overcoming the limits of this application, has led scientific research in this area to obtain interesting results that bode well for the future. (2) Methods: a search for articles on the application of ultrasounds in dentistry was performed using the PubMed electronic database. (3) Results: only 32 studies were included, and these clearly stated that this examination is widely usable and in great progress. (4) Conclusions: regarding the modern application techniques of this diagnostic test, it is essential to consider technological evolution as an objective to reduce the damage and side effects of necessary diagnostic tests. The use of ultrasound in dentistry can represent a valid radiation-free alternative, in certain contexts, to the other most used exams.
Collapse
|
18
|
Thöne-Mühling M, Kripfgans OD, Mengel R. Ultrasonography for noninvasive and real-time evaluation of peri-implant soft and hard tissue: a case series. Int J Implant Dent 2021; 7:95. [PMID: 34518926 PMCID: PMC8438098 DOI: 10.1186/s40729-021-00375-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 06/25/2021] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND The diagnosis of soft and hard tissue at dental implants will be challenging in the future, as high prevalence of mucositis and peri-implantitis were described in the population. Ultrasonography is a promising non-invasive, inexpensive, painless, and radiation-free method for imaging hard and soft tissue at implants, especially an ultrasound device with a 25-MHz probe demonstrating a high correlation between ultrasound, clinical, and radiological measurements. CASE PRESENTATION The following case series demonstrates the use of ultrasonography with high spatial resolution probe in patients with dental implants affected by soft tissue recession and/or crestal bone loss. CONCLUSION These ultrasound images can provide valuable additional information for the assessment of peri-implant soft and hard tissue.
Collapse
Affiliation(s)
- Miriam Thöne-Mühling
- Department of Prosthetic Dentistry, School of Dental Medicine, Philipps-University Marburg, Georg-Voigt Str. 3, 35039, Marburg/Lahn, Germany
| | - Oliver D Kripfgans
- Department of Radiology, BME, and Appl. Phys., University of Michigan, 3218D Med Sci I, 1301 Catherine Street, Ann Arbor, MI, 48109-5667, USA
| | - Reiner Mengel
- Department of Prosthetic Dentistry, School of Dental Medicine, Philipps-University Marburg, Georg-Voigt Str. 3, 35039, Marburg/Lahn, Germany.
| |
Collapse
|
19
|
Nguyen KCT, Le BM, Li M, Almeida FT, Major PW, Kaipatur NR, Lou EHM, Punithakumar K, Le LH. Localization of cementoenamel junction in intraoral ultrasonographs with machine learning. J Dent 2021; 112:103752. [PMID: 34314726 DOI: 10.1016/j.jdent.2021.103752] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/21/2021] [Accepted: 07/20/2021] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE Our goal was to automatically identify the cementoenamel junction (CEJ) location in ultrasound images using deep convolution neural networks (CNNs). METHODS Three CNNs were evaluated using 1400 images and data augmentation. The training and validation were performed by an experienced nonclinical rater with 1000 and 200 images, respectively. Four clinical raters with different levels of experience with ultrasound tested the networks using the other 200 images. In addition to the comparison of the best approach with each rater, we also employed the simultaneous truth and performance level estimation (STAPLE) algorithm to estimate a ground truth based on all labelings by four clinical raters. The final CEJ location estimate was obtained by taking the first moment of the posterior probability computed using the STAPLE algorithm. The study also computed the machine learning-measured CEJ-alveolar bone crest distance. RESULTS Quantitative evaluations of the 200 images showed that the comparison of the best approach with the STAPLE-estimate yielded a mean difference (MD) of 0.26 mm, which is close to the comparison with the most experienced nonclinical rater (MD=0.25 mm) but far better than the comparison with clinical raters (MD=0.27-0.33 mm). The machine learning-measured CEJ-alveolar bone crest distances correlated strongly (R = 0.933, p < 0.001) with the manual clinical labeling and the measurements were in good agreement with the 95% Bland-Altman's lines of agreement between -0.68 and 0.57 mm. CONCLUSIONS The study demonstrated the feasible use of machine learning methodology to localize CEJ in ultrasound images with clinically acceptable accuracy and reliability. Likelihood-weighted ground truth by combining multiple labels by the clinical experts compared favorably with the predictions by the best deep CNN approach. CLINICAL SIGNIFICANCE Identification of CEJ and its distance from the alveolar bone crest play an important role in the evaluation of periodontal status. Machine learning algorithms can learn from complex features in ultrasound images and have potential to provide a reliable and accurate identification in subsecond. This will greatly assist dental practitioners to provide better point-of-care to patients and enhance the throughput of dental care.
Collapse
Affiliation(s)
- Kim-Cuong T Nguyen
- Department of Radiology & Diagnostic Imaging, University of Alberta, Edmonton, Canada; Department of Biomedical Engineering, University of Alberta, Edmonton, Canada
| | - Binh M Le
- Department of Radiology & Diagnostic Imaging, University of Alberta, Edmonton, Canada; Department of Computer Sciences, University of Science, Ho Chi Minh City, Vietnam
| | - Mengxun Li
- Department of Implantology, School and Hospital of Stomatology, Wuhan University, Wuhan, China
| | | | - Paul W Major
- School of Dentistry, University of Alberta, Edmonton, Canada
| | | | - Edmond H M Lou
- Department of Biomedical Engineering, University of Alberta, Edmonton, Canada; Department of Electrical & Computer Engineering, University of Alberta, Edmonton, Canada
| | | | - Lawrence H Le
- Department of Radiology & Diagnostic Imaging, University of Alberta, Edmonton, Canada; Department of Biomedical Engineering, University of Alberta, Edmonton, Canada; School of Dentistry, University of Alberta, Edmonton, Canada.
| |
Collapse
|
20
|
Sönmez G, Kamburoğlu K, Gülşahı A. Accuracy of high-resolution ultrasound (US) for gingival soft tissue thickness mesurement in edentulous patients prior to implant placement. Dentomaxillofac Radiol 2021; 50:20200309. [PMID: 33201732 DOI: 10.1259/dmfr.20200309] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVES To evaluate and compare the accuracy of high-resolution ultrasound (US) with two different cone beam CT (CBCT) units and clinical assessment for measuring gingival soft tissue thickness in edentulous patients prior to implant placement. METHODS AND MATERIALS The study consisted of 40 maxillary implant sites of 40 healthy patients (20 females, 20 males; mean age, 47.88 years). We prospectively evaluated labial/buccal gingival thickness in 40 implant regions (16 anterior and 24 posterior) by using limited field of view (FOV) CBCT images and US images in comparison to gold standard transgingival probing measurements. One-way analysis of variance (ANOVA) was used to compare mean measurements obtained from CBCT (Morita and Planmeca), US, and transgingival probing. Interclass correlation coefficient (ICC) estimates were calculated based on means with two-way mixed and absolute-agreement model. Bland Altman plot was used to describe agreement between clinical vs US and CBCT measurements by constructing limits of agreement. Statistical significance was set at p < 0.05. RESULTS There was no significant difference between methods used according to mean gingival thickness measurements obtained from the top (p = 0.519) and bottom (p = 0.346) of the alveolar process. US and CBCT measurements highly correlated with clinical measurements for both top and bottom alveolar process gingival thickness (p < 0.001). Distribution of differences between clinical measurements and both CBCT measurements showed statistically significant differences according to 0 (p < 0.05). Distribution of differences between clinical measurements and US measurements did not show statistically significant difference (p > 0.05). CONCLUSION High-resolution US provided accurate information for the measurement of gingival soft tissue thickness in edentulous patients prior to implant placement.
Collapse
Affiliation(s)
- Gül Sönmez
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Kıvanç Kamburoğlu
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Ayşe Gülşahı
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Başkent University, Ankara, Turkey
| |
Collapse
|
21
|
Computer-Assisted Detection of Cemento-Enamel Junction in Intraoral Ultrasonographs. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11135850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The cemento-enamel junction (CEJ) is an important reference point for various clinical measurements in oral health assessment. Identifying CEJ in ultrasound images is a challenging task for dentists. In this study, a computer-assisted detection method is proposed to identify the CEJ in ultrasound images, based on the curvature change of the junction outlining the upper edge of the enamel and cementum at the cementum–enamel intersection. The technique consists of image preprocessing steps for image enhancement, segmentation, and edge detection to locate the boundary of the enamel and cementum. The effects of the image preprocessing and the sizes of the bounding boxes enclosing the CEJ were studied. For validation, the algorithm was applied to 120 images acquired from human volunteers. The mean difference of the best performance between the proposed method and the two raters’ measurements was an average of 0.25 mm with reliability ≥ 0.98. The proposed method has the potential to assist dental professionals in CEJ identification on ultrasonographs to provide better patient care.
Collapse
|
22
|
The Chairside Periodontal Diagnostic Toolkit: Past, Present, and Future. Diagnostics (Basel) 2021; 11:diagnostics11060932. [PMID: 34067332 PMCID: PMC8224643 DOI: 10.3390/diagnostics11060932] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 05/07/2021] [Accepted: 05/19/2021] [Indexed: 12/22/2022] Open
Abstract
Periodontal diseases comprise a group of globally prevalent, chronic oral inflammatory conditions caused by microbial dysbiosis and the host immune response. These diseases specifically affect the tooth-supporting tissues (i.e., the periodontium) but are also known to contribute to systemic inflammation. If left untreated, periodontal diseases can ultimately progress to tooth loss, lead to compromised oral function, and negatively impact the overall quality of life. Therefore, it is important for the clinician to accurately diagnose these diseases both early and accurately chairside. Currently, the staging and grading of periodontal diseases are based on recording medical and dental histories, thorough oral examination, and multiple clinical and radiographic analyses of the periodontium. There have been numerous attempts to improve, automate, and digitize the collection of this information with varied success. Recent studies focused on the subgingival microbiome and the host immune response suggest there is an untapped potential for non-invasive oral sampling to assist clinicians in the chairside diagnosis and, potentially, prognosis. Here, we review the available toolkit available for diagnosing periodontal diseases, discuss commercially available options, and highlight the need for collaborative research initiatives and state-of-the-art technology development across disciplines to overcome the challenges of rapid periodontal disease diagnosis.
Collapse
|
23
|
Yi J, Nguyen KCT, Wang W, Yang W, Pan M, Lou E, Major PW, Le LH, Zeng H. Mussel-Inspired Adhesive Double-Network Hydrogel for Intraoral Ultrasound Imaging. ACS APPLIED BIO MATERIALS 2020; 3:8943-8952. [PMID: 35019570 DOI: 10.1021/acsabm.0c01211] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Periodontal diseases could be diagnosed through intraoral ultrasound imaging with the advantages of simple operation procedures, low cost, and low safety risks. A couplant is normally placed between transducers and tissues for better ultrasound image quality. If applied intraorally, the couplants should possess good stability in water and robust mechanical properties, as well as strong adhesiveness to transducers and tissues. However, commercial couplants, such as Aquaflex (AF) cannot fulfill these requirements. In this work, inspired by the mussel adhesion mechanism, we reported a poly(vinyl alcohol)-polyacrylamide-polydopamine (PVA-PAM-PDA) hydrogel synthesized by incorporating PDA into the PAM-PVA double-network for intraoral ultrasound imaging. The hydrogel maintains good stability in water as well as exceptional mechanical properties and can adhere to different substrates (i.e., metal, glass, and porcine skin) without losing the original adhesion strength after multiple adhesion-strip cycles. Besides, when applied to porcine mandibular incisor imaging, the PVA-PAM-PDA hydrogel possesses good image quality for diagnosis as AF does. This work provides practical insights into the fabrication of multifunctional hydrogel-based interfaces between human tissues and medical devices for disease diagnosis applications.
Collapse
Affiliation(s)
- Jiaqiang Yi
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada
| | - Kim-Cuong T Nguyen
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta T6G 2R7, Canada.,Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta T6G 2V2, Canada
| | - Wenda Wang
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada
| | - Wenshuai Yang
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada
| | - Mingfei Pan
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada
| | - Edmond Lou
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada
| | - Paul W Major
- School of Dentistry, University of Alberta, Edmonton, Alberta T6G 1C9, Canada
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta T6G 2R7, Canada.,Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta T6G 2V2, Canada.,School of Dentistry, University of Alberta, Edmonton, Alberta T6G 1C9, Canada
| | - Hongbo Zeng
- Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada
| |
Collapse
|
24
|
Yi J, Nguyen KCT, Wang W, Yang W, Pan M, Lou E, Major PW, Le LH, Zeng H. Polyacrylamide/Alginate double-network tough hydrogels for intraoral ultrasound imaging. J Colloid Interface Sci 2020; 578:598-607. [DOI: 10.1016/j.jcis.2020.06.015] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 05/24/2020] [Accepted: 06/03/2020] [Indexed: 12/20/2022]
|
25
|
Abstract
The use of intraoral ultrasound imaging has received great attention recently due to the benefits of being a portable and low-cost imaging solution for initial and continuing care that is noninvasive and free of ionizing radiation. Alveolar bone is an important structure in the periodontal apparatus to support the tooth. Accurate assessment of alveolar bone level is essential for periodontal diagnosis. However, interpretation of alveolar bone structure in ultrasound images is a challenge for clinicians. This work is aimed at automatically segmenting alveolar bone and locating the alveolar crest via a machine learning (ML) approach for intraoral ultrasound images. Three convolutional neural network–based ML methods were trained, validated, and tested with 700, 200, and 200 images, respectively. To improve the robustness of the ML algorithms, a data augmentation approach was introduced, where 2100 additional images were synthesized through vertical and horizontal shifting as well as horizontal flipping during the training process. Quantitative evaluations of 200 images, as compared with an expert clinician, showed that the best ML approach yielded an average Dice score of 85.3%, sensitivity of 88.5%, and specificity of 99.8%, and identified the alveolar crest with a mean difference of 0.20 mm and excellent reliability (intraclass correlation coefficient ≥0.98) in less than a second. This work demonstrated the potential use of ML to assist general dentists and specialists in the visualization of alveolar bone in ultrasound images.
Collapse
|
26
|
Chan HL, Kripfgans OD. Ultrasonography for diagnosis of peri-implant diseases and conditions: a detailed scanning protocol and case demonstration. Dentomaxillofac Radiol 2020; 49:20190445. [PMID: 32017634 DOI: 10.1259/dmfr.20190445] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVES Ultrasonography has shown its promising diagnostic value in dental implant imaging research in the three treatment phases, namely, planning, intraoperative, and postoperative phase. With increasing awareness of peri-implant diseases and a lack of an efficient diagnostic method, the aim is to propose ultrasound imaging as a potential solution by providing a detailed scanning protocol and case demonstration. METHODS Ultrasound device specification and the setup for optimizing peri-implant tissue imaging was described. Two useful imaging modes, viz. B-mode and color flow, were introduced. Important anatomical structures for accurate diagnosis of peri-implant diseases were illustrated. Finally, a detailed scanning sequence was proposed. RESULTS Ultrasound images were acquired on live humans to exemplify the four peri-implant diseases and conditions, endorsed by the 2017 World Workshop organized by the American Academy of Periodontology and the European Federation of Periodontology. Ultrasound can provide not only cross-sectional anatomical images but also functional images (color flow images) that may be useful for evaluating the degree of peri-implant tissue inflammation. CONCLUSIONS High-frequency ultrasonography could be another cross-sectional imaging modality in adjunct to radiographs for diagnosing imminent peri-implant diseases and conditions that negatively influence quality of life of millions of patients with implants. This case study provides a framework for future related research work and clinical scanning guidelines.
Collapse
Affiliation(s)
- Hsun-Liang Chan
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Oliver D Kripfgans
- Department of Biomedical Engineering, College of Engineering, Ann Arbor, MI, USA.,Department of Radiology, University of Michigan Medical School, Ann Arbor, MI, USA
| |
Collapse
|
27
|
Duong DQ, Nguyen KCT, Kaipatur NR, Lou EHM, Noga M, Major PW, Punithakumar K, Le LH. Fully Automated Segmentation of Alveolar Bone Using Deep Convolutional Neural Networks from Intraoral Ultrasound Images. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:6632-6635. [PMID: 31947362 DOI: 10.1109/embc.2019.8857060] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Delineation of alveolar bone aids the diagnosis and treatment of periodontal diseases. In current practice, conventional 2D radiography and 3D cone-beam computed tomography (CBCT) imaging are used as the non-invasive approaches to image and delineate alveolar bone structures. Recently, high-frequency ultrasound imaging is proposed as an alternative to conventional imaging methods to prevent the harmful effects of ionizing radiation. However, the manual delineation of alveolar bone from ultrasound imaging is time-consuming and subject to inter and intraobserver variability. This study proposes to use a convolutional neural network-based machine learning framework to automatically segment the alveolar bone from ultrasound images. The proposed method consists of a homomorphic filtering based noise reduction and a u-net machine learning framework for automated delineation. The proposed method was evaluated over 15 ultrasound images of tooth acquired from procine specimens. The comparisons against manual ground truth delineations performed by three experts in terms of mean Dice score and Hausdorff distance values demonstrate that the proposed method yielded an improved performance over a recent state of the art graph cuts based method.
Collapse
|
28
|
Tattan M, Sinjab K, Lee E, Arnett M, Oh TJ, Wang HL, Chan HL, Kripfgans OD. Ultrasonography for chairside evaluation of periodontal structures: A pilot study. J Periodontol 2020; 91:890-899. [PMID: 31837020 DOI: 10.1002/jper.19-0342] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Revised: 12/02/2019] [Accepted: 12/03/2019] [Indexed: 12/17/2022]
Abstract
BACKGROUND The crestal bone level and soft tissue dimension are essential for periodontal diagnosis and phenotype determination; yet, existing measurement methods have limitations. The aim of this clinical study was to evaluate the correlation and accuracy of ultrasound in measuring periodontal dimensions, compared to direct clinical and cone-beam computed tomography (CBCT) methods. METHODS A 24-MHz ultrasound probe prototype, specifically designed for intraoral use, was employed. Periodontal soft tissue dimensions and crestal bone levels were measured at 40 teeth and 20 single missing tooth gaps from 20 patients scheduled to receive a dental implant surgery. The ultrasound images were interpreted by two calibrated examiners. Inter-rater agreement was calculated by using inter-rater correlation coefficient (ICC). Ultrasound readings were compared with direct clinical and CBCT readings by using ICC and Bland-Altman analysis. RESULTS The following six parameters were measured: 1) interdental papilla height (tooth), 2) mid-facial soft tissue height (tooth), 3) mucosal thickness (tooth), 4) soft tissue height (edentulous ridge), 5) mucosal thickness (edentulous ridge), and 6) crestal bone level (tooth). Intra-examiner calibrations were exercised to achieve an agreement of at least 0.8. ICC between the two readers ranged from 0.482 to 0.881. ICC between ultrasound and direct readings ranged from 0.667 to 0.957. The mean difference in mucosal thickness (tooth) between the ultrasound and direct readings was -0.015 mm (95% CI: -0.655 to 0.624 mm) without statistical significance. ICC between ultrasound and CBCT ranged from 0.654 to 0.849 among the measured parameters. The mean differences between ultrasound and CBCT range from -0.213 to 0.455 mm, without statistical significance. CONCLUSION Ultrasonic imaging can be valuable for accurate and real-time periodontal diagnosis without concerns about ionizing radiation.
Collapse
Affiliation(s)
- Mustafa Tattan
- Department of Periodontics and Iowa Institute for Oral Health Research, University of Iowa College of Dentistry, Iowa City, IA, USA
| | - Khaled Sinjab
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Eunjee Lee
- Department of Information and Statistics, Chungnam National University, Daejoen, South Korea
| | - Michelle Arnett
- Department of Primary Dental Care, Division of Dental Hygiene, University of Minnesota, Minneapolis, MN, USA
| | - Tae-Ju Oh
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Hom-Lay Wang
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Hsun-Liang Chan
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Oliver D Kripfgans
- Department of Radiology, University of Michigan Medical School, Ann Arbor, MI, USA.,Department of Biomedical Engineering, College of Engineering, Ann Arbor, MI, USA
| |
Collapse
|
29
|
Chifor R, Badea AF, Chifor I, Mitrea DA, Crisan M, Badea ME. Periodontal evaluation using a non-invasive imaging method (ultrasonography). Med Pharm Rep 2019; 92:S20-S32. [PMID: 31989105 PMCID: PMC6978923 DOI: 10.15386/mpr-1521] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 09/16/2019] [Accepted: 09/30/2019] [Indexed: 12/14/2022] Open
Abstract
The periodontal disease and gingival bleeding are highly prevalent in the adult population worldwide. The World Health Organization (WHO) data shows that 90–100% of the 34-year-old adults present gingival inflammation. Therefore, an investigation method is required to allow the assessment of the periodontal disease as well as the monitoring of the evolution of the gingival inflammation after periodontal treatments. Non-invasive and operator-independent methods for periodontal examination are necessary for diagnosing and monitoring the periodontal disease. The periodontal ultrasonography is a reliable technique for visualizing the anatomical elements which are necessary to diagnose the periodontal status. Using this imaging technique the dentino-enamel junction, the cortical bone, the radicular surface from the crown to the alveolar bone, the gingival tissue can be seen without interfering with those elements during the examination. Also, calculus visualization is possible before and after scaling in order to evaluate the quality of the treatment. Using 2D ultrasonography is not feasible in dental practice as it requires extensive experience and is also time consuming. The reproducibility of the 2D slices is very difficult in order to have the possibility to compare different investigations efficiently. 3D reconstructions of the periodontal tissue can be a very good alternative to eliminate the operator dependence. Ultrasonography allows the practitioner to visualize the anatomic elements involved in making a periodontal diagnosis. It also allows tracking of subsequent changes. This method is not commonly used for periodontal examination and further studies are required. Previous studies show that ultrasonography can be a reliable non-invasive method to diagnose and monitor the periodontal disease.
Collapse
Affiliation(s)
- Radu Chifor
- Dental Prevention Department, Faculty of Dental Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Alexandru Florin Badea
- Discipline of Anatomy and Embryology, Faculty of General Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Ioana Chifor
- Dental Prevention Department, Faculty of Dental Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | | | - Maria Crisan
- Department of Histology, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Mindra Eugenia Badea
- Dental Prevention Department, Faculty of Dental Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| |
Collapse
|
30
|
Marotti J, Neuhaus S, Habor D, Bohner L, Heger S, Radermacher K, Wolfart S. High-Frequency Ultrasound for Assessment of Peri-Implant Bone Thickness. J Clin Med 2019; 8:jcm8101539. [PMID: 31557872 PMCID: PMC6832403 DOI: 10.3390/jcm8101539] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 09/20/2019] [Accepted: 09/23/2019] [Indexed: 01/20/2023] Open
Abstract
Purpose: The aim of this study was to evaluate the accuracy of high-frequency ultrasound (HFUS) for measurement of bone thickness surrounding dental implants. Methods: Eight porcine bone samples containing dental implants were scanned by a HFUS scanner and compared using cone-beam computed tomography (CBCT) and an optical scanner. Bone thickness was measured in the buccolingual region of dental implants in 10 points distributed between the platform and apical portion of the implant. Results: The mean measurement error for the ultrasound method was 0.11 mm, whereas CBCT showed a measurement error of 0.20 mm. For both devices, the maximal measurement error was 0.28 mm. Conclusion: Within the simulated limited conditions of this study, high-frequency ultrasound, with optical scanning used as a reference, presented higher accuracy in comparison to CBCT, and seems to be a promising tool for measuring peri-implant bone.
Collapse
Affiliation(s)
- Juliana Marotti
- Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
| | - Sarah Neuhaus
- Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
| | - Daniel Habor
- Department of Medical Engineering, RWTH Aachen University, Pauwelsstrasse 20, 52074 Aachen, Germany.
| | - Lauren Bohner
- Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
| | - Stefan Heger
- Institute for Biomedical Engineering, Mannheim University, John-Deere-Strasse 85, 68163 Mannheim, Germany.
| | - Klaus Radermacher
- Department of Medical Engineering, RWTH Aachen University, Pauwelsstrasse 20, 52074 Aachen, Germany.
| | - Stefan Wolfart
- Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Pauwelsstrasse 30, 52074 Aachen, Germany.
| |
Collapse
|
31
|
Kamburoğlu K, Karagöz B, Altan H, Özen D. An ex vivo comparative study of occlusal and proximal caries using terahertz and X-ray imaging. Dentomaxillofac Radiol 2018; 48:20180250. [PMID: 30379560 DOI: 10.1259/dmfr.20180250] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
OBJECTIVES: To examine the effectiveness of terahertz (THz) pulsed imaging (TPI) in comparison to intraoral photostimulable phosphor late (PSP) and cone beam CT (CBCT) for the detection of dental caries ex vivo. METHODS: Newly extracted 32 human permanent teeth surfaces (16 with caries and 16 without caries) were serially sectioned mesiodistally and imaged by using four image sets as follows: (1) CBCT; (2) PSP; (3) THz movie video; and (4) THz static images. All images were evaluated twice separately by two calibrated observers for the presence/absence of caries using a 5-grade rating/confidence scale. Weighted κ coefficients were calculated. Different image sets were compared with the histological gold-standard using the receiver operating characteristic and area under curves for each image set were compared using χ2 tests, with a significance level of α = 0.05. RESULTS: Intra- and interobserverκ-values for all image sets were almost excellent ranging between 0.777 and 0.988. Mean Az values of observers and readings were 0.898 for CBCT, 0.888 for PSP images, 0.853 for THz static images and 0.781 for THz video movie. No statistically significant differences (p > 0.05) were found between Az values for the different image sets. When observer scores were evaluated according to caries location again no statistically significant differences (p > 0.05) were found between Az values for the occlusal and proximal caries for the four image sets. CONCLUSIONS: Terahertz pulsed imaging was found to be successful for the detection of dental caries ex vivo.
Collapse
Affiliation(s)
- Kıvanç Kamburoğlu
- 1 Department of Dentomaxillofacial Radiology, Dentistry Faculty, Ankara University , Yenimahalle , Turkey
| | - Burcu Karagöz
- 2 Department of Physics, Terahertz Research Laboratory, Middle East Technical University , Çankaya , Turkey
| | - Hakan Altan
- 2 Department of Physics, Terahertz Research Laboratory, Middle East Technical University , Çankaya , Turkey
| | - Doĝukan Özen
- 3 Department of Biostatistics, Faculty of Veterinary Medicine, Ankara University , Yenimahalle , Turkey
| |
Collapse
|
32
|
Nguyen KCT, Pachêco-Pereira C, Kaipatur NR, Cheung J, Major PW, Le LH. Comparison of ultrasound imaging and cone-beam computed tomography for examination of the alveolar bone level: A systematic review. PLoS One 2018; 13:e0200596. [PMID: 30281591 PMCID: PMC6169851 DOI: 10.1371/journal.pone.0200596] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Accepted: 06/30/2018] [Indexed: 02/01/2023] Open
Abstract
Background and objective The current methods to image alveolar bone in humans include intraoral 2D radiography and cone-beam computed tomography (CBCT). However, these methods expose the subject to ionizing radiation. Therefore, ultrasound imaging has been investigated as an alternative technique, as it is both non-invasive and free from ionizing radiation. In order to assess the validity and reliability of ultrasonography in visualizing alveolar bone, a systematic review was conducted comparing ultrasound imaging to CBCT for examination of the alveolar bone level. Study design Seven databases were searched. Studies addressing examination of alveolar bone level via CBCT and ultrasound were selected. Risk of bias under Cochrane guidelines was used as a methodological quality assessment tool. Results All the four included studies were ex vivo studies that used porcine or human cadaver samples. The alveolar bone level was measured by the distance from the alveolar bone crest to certain landmarks such as cemento-enamel junction or gingival margin. The risk of bias was found as low. The mean difference between ultrasound and CBCT measurements ranged from 0.07 mm to 0.68 mm, equivalent to 1.6% - 8.8%. Conclusions There is currently preliminary evidence to support the use of ultrasonography as compared to CBCT for the examination of alveolar bone level. Further studies comparing ultrasound to gold standard methods would be necessary to help validate the accuracy of ultrasonography as a diagnostic technique in periodontal imaging.
Collapse
Affiliation(s)
- Kim-Cuong T. Nguyen
- Department of Radiology & Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Camila Pachêco-Pereira
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
- Department of Comprehensive Dentistry, UT Health San Antonio, San Antonio, Texas, United States of America
| | - Neelambar R. Kaipatur
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
- * E-mail: (LHL); (NRK)
| | - June Cheung
- Department of Communication Sciences and Disorders, University of Alberta, Edmonton, Alberta, Canada
| | - Paul W. Major
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Lawrence H. Le
- Department of Radiology & Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada
- * E-mail: (LHL); (NRK)
| |
Collapse
|
33
|
Chan HL, Sinjab K, Li J, Chen Z, Wang HL, Kripfgans OD. Ultrasonography for noninvasive and real-time evaluation of peri-implant tissue dimensions. J Clin Periodontol 2018; 45:986-995. [PMID: 29757464 DOI: 10.1111/jcpe.12918] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Revised: 04/17/2018] [Accepted: 05/08/2018] [Indexed: 11/30/2022]
Abstract
AIM Existing methods for evaluating marginal bone loss and tissue biotype around dental implants present with many limitations. The aim of this study was to examine the accuracy of high-resolution, 3-dimensional ultrasound to measure peri-implant tissue dimensions. MATERIAL AND METHODS A 25-MHz ultrasound probe prototype was used to scan peri-implant tissues of 17 implants from seven fresh human cadavers. Four ultrasonic measurements were made as follows: the marginal bone level/thickness, and mucosal level/thickness. The readings were statistically compared to cone beam computed tomography (CBCT) and/or open bone measurements. RESULTS The correlations (r) between the ultrasound and direct/CBCT readings of the four parameters ranged from 0.85 to 0.98 (p < 0.0001). The mean absolute difference in the four parameters between ultrasound-direct and ultrasound-CBCT ranged from 0.033 to 0.24 mm. CONCLUSION Encouraging evidence is shown that ultrasound can accurately measure peri-implant tissue dimensions. Following clinical trial validations, ultrasound offers potential as a valuable tool to evaluate long-term peri-implant tissue stability without concerns of ionizing radiation and image artefacts around implants.
Collapse
Affiliation(s)
- Hsun-Liang Chan
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan
| | - Khaled Sinjab
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan
| | - Junying Li
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan.,Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Zhaozhao Chen
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan.,Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Hom-Lay Wang
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan.,Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Oliver D Kripfgans
- Department of Biomedical Engineering, College of Engineering, Ann Arbor, Michigan.,Department of Radiology, University of Michigan Medical School, Ann Arbor, Michigan
| |
Collapse
|
34
|
Bhaskar V, Chan HL, MacEachern M, Kripfgans OD. Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications. Dentomaxillofac Radiol 2018; 47:20180076. [PMID: 29791198 DOI: 10.1259/dmfr.20180076] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVES Ultrasonography has shown promising diagnostic value in dental implant imaging research; however, exactly how ultrasound was used and at what stage of implant therapy it can be applied has not been systematically evaluated. Therefore, the aim of this review is to investigate potential indications of ultrasound use in the three implant treatment phases, namely planning, intraoperative and post-operative phase. METHODS Eligible manuscripts were searched in major databases with a combination of keywords related to the use of ultrasound imaging in implant therapy. An initial search yielded 414 articles, after further review, 28 articles were finally included for this systematic review. RESULTS Ultrasound was found valuable, though at various development stages, for evaluating (1) soft tissues, (2) hard tissues (3) vital structures and (4) implant stability. B-mode, the main function to image anatomical structures of interest, has been evaluated in pre-clinical and clinical studies. Quantitative ultrasound parameters, e.g. sound speed and amplitude, are being developed to evaluate implant-bone stability, mainly in simulation and pre-clinical studies. Ultrasound could be potentially useful in all three treatment phases. In the planning phase, ultrasound could evaluate vital structures, tissue biotype, ridge width/density, and cortical bone thickness. During surgery, it can provide feedback by identifying vital structures and bone boundary. At follow-up visits, it could evaluate marginal bone level and implant stability. CONCLUSIONS Understanding the current status of ultrasound imaging research for implant therapy would be extremely beneficial for accelerating translational research and its use in dental clinics.
Collapse
Affiliation(s)
| | - Hsun-Liang Chan
- 2 Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry , Ann Arbor, MI , USA
| | - Mark MacEachern
- 3 Taubman Health Sciences Library, University of Michigan , Ann Arbor, MI , USA
| | - Oliver D Kripfgans
- 4 Department of Biomedical Engineering, College of Engineering , Ann Arbor, MI , USA.,5 Department of Radiology, University of Michigan Medical School , Ann Arbor, MI , USA
| |
Collapse
|