1
|
Zimmerling A, Boire J, Zhou Y, Chen X. Influence of Breath-Mimicking Ventilated Incubation on Three-Dimensional Bioprinted Respiratory Tissue Scaffolds. J Biomech Eng 2024; 146:091004. [PMID: 38557592 DOI: 10.1115/1.4065214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 03/28/2024] [Indexed: 04/04/2024]
Abstract
Development of respiratory tissue constructs is challenging due to the complex structure of native respiratory tissue and the unique biomechanical conditions induced by breathing. While studies have shown that the inclusion of biomechanical stimulus mimicking physiological conditions greatly benefits the development of engineered tissues, to our knowledge no studies investigating the influence of biomechanical stimulus on the development of respiratory tissue models produced through three-dimensional (3D) bioprinting have been reported. This paper presents a study on the utilization of a novel breath-mimicking ventilated incubator to impart biomechanical stimulus during the culture of 3D respiratory bioprinted constructs. Constructs were bioprinted using an alginate/collagen hydrogel containing human primary pulmonary fibroblasts with further seeding of human primary bronchial epithelial cells. Biomechanical stimulus was then applied via a novel ventilated incubator capable of mimicking the pressure and airflow conditions of multiple breathing conditions: standard incubation, shallow breathing, normal breathing, and heavy breathing, over a two-week time period. At time points between 1 and 14 days, constructs were characterized in terms of mechanical properties, cell proliferation, and morphology. The results illustrated that incubation conditions mimicking normal and heavy breathing led to greater and more continuous cell proliferation and further indicated a more physiologically relevant respiratory tissue model.
Collapse
Affiliation(s)
- Amanda Zimmerling
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada; Vaccine and Infectious Disease Organization (VIDO), University of Saskatchewan, Saskatoon, SK S7N 5E3, Canada
| | - Jim Boire
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada; RMD Engineering Inc., #1 Cory Place East Cory Industrial Park, RM Corman Park, Saskatoon, SK S7K 3J7, Canada
| | - Yan Zhou
- Vaccine and Infectious Disease Organization (VIDO), University of Saskatchewan, Saskatoon, SK S7N 5E3, Canada
| | - Xiongbiao Chen
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada; Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
| |
Collapse
|
2
|
Pesce M, Pompilio G, Bartunek J. The LIMA: A Drug-Eluting Graft and Coronary Flow Shock Absorber. Mayo Clin Proc 2023; 98:15-17. [PMID: 36603942 DOI: 10.1016/j.mayocp.2022.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 11/16/2022] [Indexed: 01/04/2023]
Affiliation(s)
| | - Giulio Pompilio
- Centro Cardiologico Monzino, IRCCS, Milan, Italy; Università di Milano, Milan, Italy
| | | |
Collapse
|
3
|
Matos RS, Maselli D, McVey JH, Heiss C, Campagnolo P. 3D Printed Bioreactor Enabling the Pulsatile Culture of Native and Angioplastied Large Arteries. Front Cardiovasc Med 2022; 9:864580. [PMID: 35800166 PMCID: PMC9253513 DOI: 10.3389/fcvm.2022.864580] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 05/13/2022] [Indexed: 12/30/2022] Open
Abstract
Routine interventions such as balloon angioplasty, result in vascular activation and remodeling, often requiring re-intervention. 2D in vitro models and small animal experiments have enabled the discovery of important mechanisms involved in this process, however the clinical translation is often underwhelming. There is a critical need for an ex vivo model representative of the human vascular physiology and encompassing the complexity of the vascular wall and the physical forces regulating its function. Vascular bioreactors for ex vivo culture of large vessels are viable alternatives, but their custom-made design and insufficient characterization often hinders the reproducibility of the experiments. The objective of the study was to design and validate a novel 3D printed cost-efficient and versatile perfusion system, capable of sustaining the viability and functionality of large porcine arteries for 7 days and enabling early post-injury evaluations. MultiJet Fusion 3D printing was used to engineer the EasyFlow insert, converting a conventional 50 ml centrifuge tube into a mini bioreactor. Porcine carotid arteries either left untreated or injured with an angioplasty balloon, were cultured under pulsatile flow for up to 7 days. Pressure, heart rate, medium viscosity and shear conditions were adjusted to resemble arterial in vivo hemodynamics. Tissue viability, cell activation and matrix remodeling were analyzed by immunohistochemistry, and vascular function was monitored by duplex ultrasound. Culture conditions in the EasyFlow bioreactor preserved endothelial coverage and smooth muscle organization and extracellular matrix structure in the vessel wall, as compared to static culture. Injured arteries presented hallmarks of early remodeling, such as intimal denudation, smooth muscle cell disarray and media/adventitia activation in flow culture. Duplex ultrasound confirmed continuous pulsatile blood flow conditions, dose-dependent vasodilator response to nitroglycerin in untreated vessels and impaired dilator response in angioplastied vessels. The scope of this work is to validate a low-cost, robust and reproducible system to explore the culture of native and injured large arteries under pulsatile flow. While the study of vascular pathology is beyond the scope of the present paper, our system enables future investigations and provides a platform to test novel therapies and devices ex vivo, in a patient relevant system.
Collapse
Affiliation(s)
- Rolando S. Matos
- Cardiovascular Section, Department of Biochemical Sciences, Guildford, United Kingdom
| | - Davide Maselli
- Cardiovascular Section, Department of Biochemical Sciences, Guildford, United Kingdom
| | - John H. McVey
- Cardiovascular Section, Department of Biochemical Sciences, Guildford, United Kingdom
| | - Christian Heiss
- Cardiovascular Section, Department of Biochemical Sciences, Guildford, United Kingdom,Clinical Medicine Section, Department of Clinical and Experimental Medicine, University of Surrey, Faculty of Health and Medical Sciences, University of Surrey, Guildford, United Kingdom
| | - Paola Campagnolo
- Cardiovascular Section, Department of Biochemical Sciences, Guildford, United Kingdom,*Correspondence: Paola Campagnolo
| |
Collapse
|
4
|
Maselli D, Garoffolo G, Cassanmagnago GA, Vono R, Ruiter MS, Thomas AC, Madeddu P, Pesce M, Spinetti G. Mechanical Strain Induces Transcriptomic Reprogramming of Saphenous Vein Progenitors. Front Cardiovasc Med 2022; 9:884031. [PMID: 35711359 PMCID: PMC9197233 DOI: 10.3389/fcvm.2022.884031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 04/28/2022] [Indexed: 11/23/2022] Open
Abstract
Intimal hyperplasia is the leading cause of graft failure in aortocoronary bypass grafts performed using human saphenous vein (SV). The long-term consequences of the altered pulsatile stress on the cells that populate the vein wall remains elusive, particularly the effects on saphenous vein progenitors (SVPs), cells resident in the vein adventitia with a relatively wide differentiation capacity. In the present study, we performed global transcriptomic profiling of SVPs undergoing uniaxial cyclic strain in vitro. This type of mechanical stimulation is indeed involved in the pathology of the SV. Results showed a consistent stretch-dependent gene regulation in cyclically strained SVPs vs. controls, especially at 72 h. We also observed a robust mechanically related overexpression of Adhesion Molecule with Ig Like Domain 2 (AMIGO2), a cell surface type I transmembrane protein involved in cell adhesion. The overexpression of AMIGO2 in stretched SVPs was associated with the activation of the transforming growth factor β pathway and modulation of intercellular signaling, cell-cell, and cell-matrix interactions. Moreover, the increased number of cells expressing AMIGO2 detected in porcine SV adventitia using an in vivo arterialization model confirms the upregulation of AMIGO2 protein by the arterial-like environment. These results show that mechanical stress promotes SVPs' molecular phenotypic switching and increases their responsiveness to extracellular environment alterations, thus prompting the targeting of new molecular effectors to improve the outcome of bypass graft procedure.
Collapse
Affiliation(s)
- Davide Maselli
- IRCCS MultiMedica, Milan, Italy
- Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, United Kingdom
| | - Gloria Garoffolo
- Unità di Ingegneria Tissutale Cardiovascolare, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Giada Andrea Cassanmagnago
- IRCCS Humanitas Research Hospital, Rozzano, Italy
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy
| | | | - Matthijs S. Ruiter
- Unità di Ingegneria Tissutale Cardiovascolare, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Anita C. Thomas
- Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, United Kingdom
| | - Paolo Madeddu
- Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, United Kingdom
| | - Maurizio Pesce
- Unità di Ingegneria Tissutale Cardiovascolare, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Gaia Spinetti
- IRCCS MultiMedica, Milan, Italy
- *Correspondence: Gaia Spinetti
| |
Collapse
|
5
|
Mathematical Models for Blood Flow Quantification in Dialysis Access Using Angiography: A Comparative Study. Diagnostics (Basel) 2021; 11:diagnostics11101771. [PMID: 34679469 PMCID: PMC8534972 DOI: 10.3390/diagnostics11101771] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 09/10/2021] [Accepted: 09/17/2021] [Indexed: 11/26/2022] Open
Abstract
Blood flow rate in dialysis (vascular) access is the key parameter to examine patency and to evaluate the outcomes of various endovascular interve7ntions. While angiography is extensively used for dialysis access–salvage procedures, to date, there is no image-based blood flow measurement application commercially available in the angiography suite. We aim to calculate the blood flow rate in the dialysis access based on cine-angiographic and fluoroscopic image sequences. In this study, we discuss image-based methods to quantify access blood flow in a flow phantom model. Digital subtraction angiography (DSA) and fluoroscopy were used to acquire images at various sampling rates (DSA—3 and 6 frames/s, fluoroscopy—4 and 10 pulses/s). Flow rates were computed based on two bolus tracking algorithms, peak-to-peak and cross-correlation, and modeled with three curve-fitting functions, gamma variate, lagged normal, and polynomial, to correct errors with transit time measurement. Dye propagation distance and the cross-sectional area were calculated by analyzing the contrast enhancement in the vessel. The calculated flow rates were correlated versus an in-line flow sensor measurement. The cross-correlation algorithm with gamma-variate curve fitting had the best accuracy and least variability in both imaging modes. The absolute percent error (mean ± SEM) of flow quantification in the DSA mode at 6 frames/s was 21.4 ± 1.9%, and in the fluoroscopic mode at 10 pulses/s was 37.4 ± 3.6%. The radiation dose varied linearly with the sampling rate in both imaging modes and was substantially low to invoke any tissue reactions or stochastic effects. The cross-correlation algorithm and gamma-variate curve fitting for DSA acquisition at 6 frames/s had the best correlation with the flow sensor measurements. These findings will be helpful to develop a software-based vascular access flow measurement tool for the angiography suite and to optimize the imaging protocol amenable for computational flow applications.
Collapse
|
6
|
Hughes DL, Hughes A, Soonawalla Z, Mukherjee S, O’Neill E. Dynamic Physiological Culture of Ex Vivo Human Tissue: A Systematic Review. Cancers (Basel) 2021; 13:2870. [PMID: 34201273 PMCID: PMC8229413 DOI: 10.3390/cancers13122870] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 05/26/2021] [Accepted: 06/03/2021] [Indexed: 12/20/2022] Open
Abstract
Conventional static culture fails to replicate the physiological conditions that exist in vivo. Recent advances in biomedical engineering have resulted in the creation of novel dynamic culturing systems that permit the recapitulation of normal physiological processes ex vivo. Whilst the physiological benefit for its use in the culture of two-dimensional cellular monolayer has been validated, its role in the context of primary human tissue culture has yet to be determined. This systematic review identified 22 articles that combined dynamic physiological culture techniques with primary human tissue culture. The most frequent method described (55%) utilised dynamic perfusion culture. A diverse range of primary human tissue was successfully cultured. The median duration of successful ex vivo culture of primary human tissue for all articles was eight days; however, a wide range was noted (5 h-60 days). Six articles (27%) reported successful culture of primary human tissue for greater than 20 days. This review illustrates the physiological benefit of combining dynamic culture with primary human tissue culture in both long-term culture success rates and preservation of native functionality of the tissue ex vivo. Further research efforts should focus on developing precise biochemical sensors that would allow for real-time monitoring and automated self-regulation of the culture system in order to maintain homeostasis. Combining these techniques allows the creation of an accurate system that can be used to gain a greater understanding of human physiology.
Collapse
Affiliation(s)
- Daniel Ll Hughes
- Department of Oncology, University of Oxford, Oxford OX3 7DQ, UK; (D.L.H.); (S.M.)
| | - Aron Hughes
- Undergraduate Centre, Cardiff University Medical School, Cardiff CF14 4YS, UK;
| | - Zahir Soonawalla
- Department of Hepatobiliary and Pancreatic Surgery, Oxford University Hospitals NHS, Oxford OX3 7LE, UK;
| | - Somnath Mukherjee
- Department of Oncology, University of Oxford, Oxford OX3 7DQ, UK; (D.L.H.); (S.M.)
| | - Eric O’Neill
- Department of Oncology, University of Oxford, Oxford OX3 7DQ, UK; (D.L.H.); (S.M.)
| |
Collapse
|
7
|
Jiao Y, Li C, Liu L, Wang F, Liu X, Mao J, Wang L. Construction and application of textile-based tissue engineering scaffolds: a review. Biomater Sci 2020; 8:3574-3600. [PMID: 32555780 DOI: 10.1039/d0bm00157k] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Tissue engineering (TE) provides a practicable method for tissue and organ repair or substitution. As the most important component of TE, a scaffold plays a critical role in providing a growing environment for cell proliferation and functional differentiation as well as good mechanical support. And the restorative effects are greatly dependent upon the nature of the scaffold including the composition, morphology, structure, and mechanical performance. Medical textiles have been widely employed in the clinic for a long time and are being extensively investigated as TE scaffolds. However, unfortunately, the advantages of textile technology cannot be fully exploited in tissue regeneration due to the ignoring of the diversity of fabric structures. Therefore, this review focuses on textile-based scaffolds, emphasizing the significance of the fabric design and the resultant characteristics of cell behavior and extracellular matrix reconstruction. The structure and mechanical behavior of the fabrics constructed by various textile techniques for different tissue repairs are summarized. Furthermore, the prospect of structural design in the TE scaffold preparation was anticipated, including profiled fibers and some unique and complex textile structures. Hopefully, the readers of this review would appreciate the importance of structural design of the scaffold and the usefulness of textile-based TE scaffolds in tissue regeneration.
Collapse
Affiliation(s)
- Yongjie Jiao
- Key Laboratory of Textile Science and Technology of Ministry of Education and College of Textiles, Donghua University, Shanghai 201620, China.
| | | | | | | | | | | | | |
Collapse
|
8
|
Garoffolo G, Ruiter MS, Piola M, Brioschi M, Thomas AC, Agrifoglio M, Polvani G, Coppadoro L, Zoli S, Saccu C, Spinetti G, Banfi C, Fiore GB, Madeddu P, Soncini M, Pesce M. Coronary artery mechanics induces human saphenous vein remodelling via recruitment of adventitial myofibroblast-like cells mediated by Thrombospondin-1. Am J Cancer Res 2020; 10:2597-2611. [PMID: 32194822 PMCID: PMC7052885 DOI: 10.7150/thno.40595] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Accepted: 11/22/2019] [Indexed: 12/27/2022] Open
Abstract
Rationale: Despite the preferred application of arterial conduits, the greater saphenous vein (SV) remains indispensable for coronary bypass grafting (CABG), especially in multi-vessel coronary artery disease (CAD). The objective of the present work was to address the role of mechanical forces in the activation of maladaptive vein bypass remodeling, a process determining progressive occlusion and recurrence of ischemic heart disease. Methods: We employed a custom bioreactor to mimic the coronary shear and wall mechanics in human SV vascular conduits and reproduce experimentally the biomechanical conditions of coronary grafting and analyzed vein remodeling process by histology, histochemistry and immunofluorescence. We also subjected vein-derived cells to cyclic uniaxial mechanical stimulation in culture, followed by phenotypic and molecular characterization using RNA and proteomic methods. We finally validated our results in vitro and using a model of SV carotid interposition in pigs. Results: Exposure to pulsatile flow determined a remodeling process of the vascular wall involving reduction in media thickness. Smooth muscle cells (SMCs) underwent conversion from contractile to synthetic phenotype. A time-dependent increase in proliferating cells expressing mesenchymal (CD44) and early SMC (SM22α) markers, apparently recruited from the SV adventitia, was observed especially in CABG-stimulated vessels. Mechanically stimulated SMCs underwent transition from contractile to synthetic phenotype. MALDI-TOF-based secretome analysis revealed a consistent release of Thrombospondin-1 (TSP-1), a matricellular protein involved in TGF-β-dependent signaling. TSP-1 had a direct chemotactic effect on SV adventitia resident progenitors (SVPs); this effects was inhibited by blocking TSP-1 receptor CD47. The involvement of TSP-1 in adventitial progenitor cells differentiation and graft intima hyperplasia was finally contextualized in the TGF-β-dependent pathway, and validated in a saphenous vein into carotid interposition pig model. Conclusions: Our results provide the evidence of a matricellular mechanism involved in the human vein arterialization process controlled by alterations in tissue mechanics, and open the way to novel potential strategies to block VGD progression based on targeting cell mechanosensing-related effectors.
Collapse
|
9
|
Wadey K, Lopes J, Bendeck M, George S. Role of smooth muscle cells in coronary artery bypass grafting failure. Cardiovasc Res 2019; 114:601-610. [PMID: 29373656 DOI: 10.1093/cvr/cvy021] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Accepted: 01/22/2018] [Indexed: 01/30/2023] Open
Abstract
Atherosclerosis is the underlying pathology of many cardiovascular diseases. The formation and rupture of atherosclerotic plaques in the coronary arteries results in angina and myocardial infarction. Venous coronary artery bypass grafts are designed to reduce the consequences of atherosclerosis in the coronary arteries by diverting blood flow around the atherosclerotic plaques. However, vein grafts suffer a high failure rate due to intimal thickening that occurs as a result of vascular cell injury and activation and can act as 'a soil' for subsequent atherosclerotic plaque formation. A clinically-proven method for the reduction of vein graft intimal thickening and subsequent major adverse clinical events is currently not available. Consequently, a greater understanding of the underlying mechanisms of intimal thickening may be beneficial for the design of future therapies for vein graft failure. Vein grafting induces inflammation and endothelial cell damage and dysfunction, that promotes vascular smooth muscle cell (VSMC) migration, and proliferation. Injury to the wall of the vein as a result of grafting leads to the production of chemoattractants, remodelling of the extracellular matrix and cell-cell contacts; which all contribute to the induction of VSMC migration and proliferation. This review focuses on the role of altered behaviour of VSMCs in the vein graft and some of the factors which critically lead to intimal thickening that pre-disposes the vein graft to further atherosclerosis and re-occurrence of symptoms in the patient.
Collapse
Affiliation(s)
- Kerry Wadey
- Bristol Medical School, Research Floor Level 7, Bristol Royal Infirmary, Bristol BS2 8HW, UK
| | - Joshua Lopes
- Translational Biology and Engineering Program, University of Toronto, Toronto, ON M5G 1M1, Canada
| | - Michelle Bendeck
- Translational Biology and Engineering Program, University of Toronto, Toronto, ON M5G 1M1, Canada
| | - Sarah George
- Bristol Medical School, Research Floor Level 7, Bristol Royal Infirmary, Bristol BS2 8HW, UK
| |
Collapse
|
10
|
Kenagy RD, Kikuchi S, Evanko SP, Ruiter MS, Piola M, Longchamp A, Pesce M, Soncini M, Deglise S, Fiore GB, Haefliger JA, Schmidt TA, Majesky MW, Sobel M, Wight TN. Versican is differentially regulated in the adventitial and medial layers of human vein grafts. PLoS One 2018; 13:e0204045. [PMID: 30265729 PMCID: PMC6161854 DOI: 10.1371/journal.pone.0204045] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Accepted: 08/31/2018] [Indexed: 12/13/2022] Open
Abstract
Changes in extracellular matrix proteins may contribute significantly to the adaptation of vein grafts to the arterial circulation. We examined the production and distribution of versican and hyaluronan in intact human vein rings cultured ex vivo, veins perfused ex vivo, and cultured venous adventitial and smooth muscle cells. Immunohistochemistry revealed higher levels of versican in the intima/media compared to the adventitia, and no differences in hyaluronan. In the vasa vasorum, versican and hyaluronan associated with CD34+ progenitor cells. Culturing the vein rings for 14 days revealed increased versican immunostaining of 30–40% in all layers, with no changes in hyaluronan. Changes in versican accumulation appear to result from increased synthesis in the intima/media and decreased degradation in the adventitia as versican transcripts were increased in the intima/media, but unchanged in the adventitia, and versikine (the ADAMTS-mediated cleavage product of versican) was increased in the intima/media, but decreased in the adventitia. In perfused human veins, versican was specifically increased in the intima/media in the presence of venous pressure, but not with arterial pressure. Unexpectedly, cultured adventitial cells express and accumulate more versican and hyaluronan than smooth muscle cells. These data demonstrate a differential regulation of versican and hyaluronan in human venous adventitia vs. intima/media and suggest distinct functions for these extracellular matrix macromolecules in these venous wall compartments during the adaptive response of vein grafts to the arterial circulation.
Collapse
Affiliation(s)
- Richard D. Kenagy
- Center for Cardiovascular Biology, Institute for Stem Cells and Regenerative Medicine, and Department of Surgery, University of Washington, Seattle, WA, United States of America
- * E-mail:
| | - Shinsuke Kikuchi
- Department of Vascular Surgery, Asahikawa Medical University, Asahikawa, Japan
| | - Steve P. Evanko
- Matrix Biology Program, Benaroya Research Institute, Seattle, WA, United States of America
| | - Matthijs S. Ruiter
- Cardiovascular Tissue Engineering Unit—Centro Cardiologico Monzino, IRCCS, Via Parea, 4, Milan, Italy
| | - Marco Piola
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Alban Longchamp
- Department of Vascular Surgery, CHUV | Lausanne University Hospital, Lausanne, Switzerland
| | - Maurizio Pesce
- Cardiovascular Tissue Engineering Unit—Centro Cardiologico Monzino, IRCCS, Via Parea, 4, Milan, Italy
| | - Monica Soncini
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Sébastien Deglise
- Department of Vascular Surgery, CHUV | Lausanne University Hospital, Lausanne, Switzerland
| | - Gianfranco B. Fiore
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | | | - Tannin A. Schmidt
- Biomedical Engineering Department, School of Dental Medicine, University of Connecticut Health Center, Farmington, CT, United States of America
| | - Mark W. Majesky
- Center for Developmental Biology and Regenerative Medicine, Seattle Children's Research Institute, Seattle, WA, United States of America
| | - Michael Sobel
- Division of Vascular Surgery, VA Puget Sound Health Care System, University of Washington, Seattle, WA, United States of America
| | - Thomas N. Wight
- Matrix Biology Program, Benaroya Research Institute, Seattle, WA, United States of America
| |
Collapse
|
11
|
Prim DA, Potts JD, Eberth JF. Pulsatile Perfusion Bioreactor for Biomimetic Vascular Impedances. J Med Device 2018. [DOI: 10.1115/1.4040648] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Pulsatile waves of blood pressure and flow are continuously augmented by the resistance, compliance, and inertance properties of the vasculature, resulting in unique wave characteristics at distinct anatomical locations. Hemodynamically generated loads, transduced as physical signals into resident vascular cells, are crucial to the maintenance and preservation of a healthy vascular physiology; thus, failure to recreate biomimetic loading in vitro can lead to pathological gene expression and aberrant remodeling. As a generalized approach to improve native and engineered blood vessels, we have designed, built, and tested a pulsatile perfusion bioreactor based on biomimetic impedances and a novel five-element electrohydraulic analog. Here, the elements of an incubator-based culture system were formulaically designed to match the vascular impedance of a brachial artery by incorporating both the inherent (systemic) and added elements of the physical system into the theoretical approach. Freshly harvested porcine saphenous veins were perfused within a physiological culture chamber for 6 h and the relative expression of seven known mechanically sensitive remodeling genes analyzed using the quantitative polymerase chain reaction (qPCR) method. Of these, we found plasminogen activator inhibitor-1 (SERPINE1) and fibronectin-1 (FN1) to be highly sensitive to differences between arterial- and venous-like culture conditions. The analytical approach and biological confirmation provide a framework toward the general design of long-term hemodynamic-mimetic vascular culture systems.
Collapse
Affiliation(s)
- David A. Prim
- College of Engineering and Computing, Biomedical Engineering Program, University of South Carolina, Columbia, SC 29208
| | - Jay D. Potts
- School of Medicine, Department of Cell Biology and Anatomy, College of Engineering and Computing, Biomedical Engineering Program, University of South Carolina, Columbia, SC 29208
| | - John F. Eberth
- School of Medicine, Department of Cell Biology and Anatomy, College of Engineering and Computing, Biomedical Engineering Program, University of South Carolina, Columbia, SC 29208 e-mail:
| |
Collapse
|
12
|
Abstract
Objective: Invasive coronary interventions can fail due to intimal hyperplasia and restenosis.
Endothelial cell (EC) seeding to the vessel lumen, accelerating re-endothelialization,
or local release of mTOR pathway inhibitors have helped reduce intimal hyperplasia after
vessel injury. While animal models are powerful tools, they are complex and expensive,
and not always reflective of human physiology. Therefore, we developed an in
vitro 3D vascular model validating previous in vivo animal
models and utilizing isolated human arteries to study vascular remodeling after injury.
Approach: We utilized a bioreactor that enables the control of intramural
pressure and shear stress in vessel conduits to investigate the vascular response in
both rat and human arteries to intraluminal injury. Results: Culturing rat aorta segments in vitro, we show that vigorous removal
of luminal ECs results in vessel injury, causing medial proliferation by Day-4 and
neointima formation, with the observation of SCA1+ cells (stem cell
antigen-1) in the intima by Day-7, in the absence of flow. Conversely, when
endothelial-denuded rat aortae and human umbilical arteries were subjected to arterial
shear stress, pre-seeding with human umbilical ECs decreased the number and
proliferation of smooth muscle cell (SMC) significantly in the media of both rat and
human vessels. Conclusion: Our bioreactor system provides a novel platform for correlating ex
vivo findings with vascular outcomes in vivo. The present
in vitro human arterial injury model can be helpful in the study of
EC-SMC interactions and vascular remodeling, by allowing for the separation of
mechanical, cellular, and soluble factors.
Collapse
Affiliation(s)
- Mehmet H Kural
- 1 Vascular Biology and Therapeutics Program, Yale University School of Medicine, New Haven, CT, USA.,2 Department of Anesthesiology, Yale University, New Haven, CT, USA
| | - Guohao Dai
- 3 Department of Bioengineering, Northeastern University, Boston, MA, USA
| | - Laura E Niklason
- 1 Vascular Biology and Therapeutics Program, Yale University School of Medicine, New Haven, CT, USA.,2 Department of Anesthesiology, Yale University, New Haven, CT, USA.,4 Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Liqiong Gui
- 1 Vascular Biology and Therapeutics Program, Yale University School of Medicine, New Haven, CT, USA.,2 Department of Anesthesiology, Yale University, New Haven, CT, USA
| |
Collapse
|
13
|
Artificial Circulatory Model for Analysis of Human and Artificial Vessels. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8071017] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
14
|
Ruiter MS, Pesce M. Mechanotransduction in Coronary Vein Graft Disease. Front Cardiovasc Med 2018; 5:20. [PMID: 29594150 PMCID: PMC5861212 DOI: 10.3389/fcvm.2018.00020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 02/22/2018] [Indexed: 12/19/2022] Open
Abstract
Autologous saphenous veins are the most commonly used conduits in revascularization of the ischemic heart by coronary artery bypass graft surgery, but are subject to vein graft failure. The current mini review aims to provide an overview of the role of mechanotransduction signalling underlying vein graft failure to further our understanding of the disease progression and to improve future clinical treatment. Firstly, limitation of damage during vein harvest and engraftment can improve outcome. In addition, cell cycle inhibition, stimulation of Nur77 and external grafting could form interesting therapeutic options. Moreover, the Hippo pathway, with the YAP/TAZ complex as the main effector, is emerging as an important node controlling conversion of mechanical signals into cellular responses. This includes endothelial cell inflammation, smooth muscle cell proliferation/migration, and monocyte attachment/infiltration. The combined effects of expression levels and nuclear/cytoplasmic translocation make YAP/TAZ interesting novel targets in the prevention and treatment of vein graft disease. Pharmacological, molecular and/or mechanical conditioning of saphenous vein segments between harvest and grafting may potentiate targeted and specific treatment to improve long-term outcome.
Collapse
Affiliation(s)
- Matthijs Steven Ruiter
- Cardiovascular Tissue Engineering Unit, Centro Cardiologico Monzino (IRCCS), Milan, Italy
| | - Maurizio Pesce
- Cardiovascular Tissue Engineering Unit, Centro Cardiologico Monzino (IRCCS), Milan, Italy
| |
Collapse
|
15
|
Abstract
A new three-dimensional model of the blood-brain barrier can be used to study processes that are involved in neurodegenerative diseases.
Collapse
Affiliation(s)
- Courtney Lane-Donovan
- Department of Neurology, University of California San Francisco, San Franciso, United States
| | - Joachim Herz
- Department of Molecular Genetics, University of Texas Southwestern Medical Center, Dallas, United States.,Department of Neuroscience, University of Texas Southwestern Medical Center, Dallas, United States.,Department of Center for Translational Neurodegeneration Research, University of Texas Southwestern Medical Center, Dallas, United States.,Department of Neurology and Neurotherapeutics, University of Texas Southwestern Medical Center, Dallas, United States
| |
Collapse
|
16
|
Garcia JR, Sanyal A, Fatemifar F, Mottahedi M, Han HC. Twist buckling of veins under torsional loading. J Biomech 2017; 58:123-130. [PMID: 28526174 DOI: 10.1016/j.jbiomech.2017.04.018] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Revised: 03/31/2017] [Accepted: 04/24/2017] [Indexed: 10/19/2022]
Abstract
Veins are often subjected to torsion and twisted veins can hinder and disrupt normal blood flow but their mechanical behavior under torsion is poorly understood. The objective of this study was to investigate the twist deformation and buckling behavior of veins under torsion. Twist buckling tests were performed on porcine internal jugular veins (IJVs) and human great saphenous veins (GSVs) at various axial stretch ratio and lumen pressure conditions to determine their critical buckling torques and critical buckling twist angles. The mechanical behavior under torsion was characterized using a two-fiber strain energy density function and the buckling behavior was then simulated using finite element analysis. Our results demonstrated that twist buckling occurred in all veins under excessive torque characterized by a sudden kink formation. The critical buckling torque increased significantly with increasing lumen pressure for both porcine IJV and human GSV. But lumen pressure and axial stretch had little effect on the critical twist angle. The human GSVs are stiffer than the porcine IJVs. Finite element simulations captured the buckling behavior for individual veins under simultaneous extension, inflation, and torsion with strong correlation between predicted critical buckling torques and experimental data (R2=0.96). We conclude that veins can buckle under torsion loading and the lumen pressure significantly affects the critical buckling torque. These results improve our understanding of vein twist behavior and help identify key factors associated in the formation of twisted veins.
Collapse
Affiliation(s)
- Justin R Garcia
- Department of Mechanical Engineering, University of Texas at San Antonio, USA; Biomedical Engineering Program, UTSA-UTHSCSA, USA
| | - Arnav Sanyal
- Department of Mechanical Engineering, University of Texas at San Antonio, USA
| | - Fatemeh Fatemifar
- Department of Mechanical Engineering, University of Texas at San Antonio, USA
| | - Mohammad Mottahedi
- Department of Mechanical Engineering, University of Texas at San Antonio, USA
| | - Hai-Chao Han
- Department of Mechanical Engineering, University of Texas at San Antonio, USA; Biomedical Engineering Program, UTSA-UTHSCSA, USA; Institute of Mechanobiology & Medical Engineering, Shanghai Jiaotong University, China.
| |
Collapse
|
17
|
A Dual-Mode Bioreactor System for Tissue Engineered Vascular Models. Ann Biomed Eng 2017; 45:1496-1510. [DOI: 10.1007/s10439-017-1813-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Accepted: 02/11/2017] [Indexed: 12/13/2022]
|