1
|
Park J, Seo B, Jeong Y, Park I. A Review of Recent Advancements in Sensor-Integrated Medical Tools. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307427. [PMID: 38460177 PMCID: PMC11132050 DOI: 10.1002/advs.202307427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 12/26/2023] [Indexed: 03/11/2024]
Abstract
A medical tool is a general instrument intended for use in the prevention, diagnosis, and treatment of diseases in humans or other animals. Nowadays, sensors are widely employed in medical tools to analyze or quantify disease-related parameters for the diagnosis and monitoring of patients' diseases. Recent explosive advancements in sensor technologies have extended the integration and application of sensors in medical tools by providing more versatile in vivo sensing capabilities. These unique sensing capabilities, especially for medical tools for surgery or medical treatment, are getting more attention owing to the rapid growth of minimally invasive surgery. In this review, recent advancements in sensor-integrated medical tools are presented, and their necessity, use, and examples are comprehensively introduced. Specifically, medical tools often utilized for medical surgery or treatment, for example, medical needles, catheters, robotic surgery, sutures, endoscopes, and tubes, are covered, and in-depth discussions about the working mechanism used for each sensor-integrated medical tool are provided.
Collapse
Affiliation(s)
- Jaeho Park
- Department of Mechanical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141South Korea
| | - Bokyung Seo
- Department of Mechanical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141South Korea
| | - Yongrok Jeong
- Department of Mechanical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141South Korea
- Radioisotope Research DivisionKorea Atomic Energy Research Institute (KAERI)Daejeon34057South Korea
| | - Inkyu Park
- Department of Mechanical EngineeringKorea Advanced Institute of Science and Technology (KAIST)Daejeon34141South Korea
| |
Collapse
|
2
|
Wang T, Li H, Pu T, Yang L. Microsurgery Robots: Applications, Design, and Development. SENSORS (BASEL, SWITZERLAND) 2023; 23:8503. [PMID: 37896597 PMCID: PMC10611418 DOI: 10.3390/s23208503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Revised: 10/07/2023] [Accepted: 10/09/2023] [Indexed: 10/29/2023]
Abstract
Microsurgical techniques have been widely utilized in various surgical specialties, such as ophthalmology, neurosurgery, and otolaryngology, which require intricate and precise surgical tool manipulation on a small scale. In microsurgery, operations on delicate vessels or tissues require high standards in surgeons' skills. This exceptionally high requirement in skills leads to a steep learning curve and lengthy training before the surgeons can perform microsurgical procedures with quality outcomes. The microsurgery robot (MSR), which can improve surgeons' operation skills through various functions, has received extensive research attention in the past three decades. There have been many review papers summarizing the research on MSR for specific surgical specialties. However, an in-depth review of the relevant technologies used in MSR systems is limited in the literature. This review details the technical challenges in microsurgery, and systematically summarizes the key technologies in MSR with a developmental perspective from the basic structural mechanism design, to the perception and human-machine interaction methods, and further to the ability in achieving a certain level of autonomy. By presenting and comparing the methods and technologies in this cutting-edge research, this paper aims to provide readers with a comprehensive understanding of the current state of MSR research and identify potential directions for future development in MSR.
Collapse
Affiliation(s)
- Tiexin Wang
- ZJU-UIUC Institute, International Campus, Zhejiang University, Haining 314400, China; (T.W.); (H.L.); (T.P.)
- School of Mechanical Engineering, Zhejiang University, Hangzhou 310058, China
| | - Haoyu Li
- ZJU-UIUC Institute, International Campus, Zhejiang University, Haining 314400, China; (T.W.); (H.L.); (T.P.)
| | - Tanhong Pu
- ZJU-UIUC Institute, International Campus, Zhejiang University, Haining 314400, China; (T.W.); (H.L.); (T.P.)
| | - Liangjing Yang
- ZJU-UIUC Institute, International Campus, Zhejiang University, Haining 314400, China; (T.W.); (H.L.); (T.P.)
- School of Mechanical Engineering, Zhejiang University, Hangzhou 310058, China
- Department of Mechanical Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
3
|
Manjila S, Rosa B, Price K, Manjila R, Mencattelli M, Dupont PE. Robotic Instruments Inside the MRI Bore: Key Concepts and Evolving Paradigms in Imaging-enhanced Cranial Neurosurgery. World Neurosurg 2023; 176:127-139. [PMID: 36639101 DOI: 10.1016/j.wneu.2023.01.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Accepted: 01/08/2023] [Indexed: 01/12/2023]
Abstract
Intraoperative MRI has been increasingly used to robotically deliver electrodes and catheters into the human brain using a linear trajectory with great clinical success. Current cranial MR guided robotics do not allow for continuous real-time imaging during the procedure because most surgical instruments are not MR-conditional. MRI guided robotic cranial surgery can achieve its full potential if all the traditional advantages of robotics (such as tremor-filtering, precision motion scaling, etc.) can be incorporated with the neurosurgeon physically present in the MRI bore or working remotely through controlled robotic arms. The technological limitations of design optimization, choice of sensing, kinematic modeling, physical constraints, and real-time control had hampered early developments in this emerging field, but continued research and development in these areas over time has granted neurosurgeons far greater confidence in using cranial robotic techniques. This article elucidates the role of MR-guided robotic procedures using clinical devices like NeuroBlate and Clearpoint that have several thousands of cases operated in a "linear cranial trajectory" and planned clinical trials, such as LAANTERN for MR guided robotics in cranial neurosurgery using LITT and MR-guided putaminal delivery of AAV2 GDNF in Parkinson's disease. The next logical improvisation would be a steerable curvilinear trajectory in cranial robotics with added DOFs and distal tip dexterity to the neurosurgical tools. Similarly, the novel concept of robotic actuators that are powered, imaged, and controlled by the MRI itself is discussed in this article, with its potential for seamless cranial neurosurgery.
Collapse
Affiliation(s)
- Sunil Manjila
- Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | - Benoit Rosa
- ICube Laboratory, UMR 7357 CNRS-University of Strasbourg, Strasbourg, France
| | - Karl Price
- Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Rehan Manjila
- Swanson School of Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Margherita Mencattelli
- Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Pierre E Dupont
- Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Barua R, Datta S, RoyChowdhury A, Datta P. Study of the surgical needle and biological soft tissue interaction phenomenon during insertion process for medical application: A Survey. Proc Inst Mech Eng H 2022; 236:1465-1477. [DOI: 10.1177/09544119221122024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The insertion of the surgical needle in soft tissue has involved significant interest in the current time because of its purpose in minimally invasive surgery (MIS) and percutaneous events like biopsies, PCNL, and brachytherapy. This study represents a review of the existing condition of investigation on insertion of a surgical needle in biological living soft tissue material. As observes the issue from numerous phases, like, analysis of the cutting forces modeling (insertion), tissue material deformation, analysis of the needle deflection for the period of the needle insertion, and the robot-controlled insertion procedures. All analysis confirms that the total needle insertion force is the total of dissimilar forces spread sideways the shaft of the insertion needle for example cutting force, stiffness force, and frictional force. Various investigations have analyzed all these kinds of forces during the needle insertion process. The force data in several measures are applied for recognizing the biological tissue materials as the needle is penetrated or for path planning. The deflection of the needle during insertion and tissue material deformation is the main trouble for defined needle placing and efforts have been prepared to model them. Applying existing models numerous insertion methods are established that are discussed in this review.
Collapse
Affiliation(s)
- Ranjit Barua
- Indian Institute of Engineering Science and Technology, Howrah, West Bengal, India
| | - Sudipto Datta
- Indian Institute of Technology, Delhi, New Delhi, Delhi, India
| | - Amit RoyChowdhury
- Indian Institute of Engineering Science and Technology, Howrah, West Bengal, India
| | - Pallab Datta
- National Institute of Pharmaceutical Education and Research-Kolkata, Kolkata, West Bengal, India
| |
Collapse
|
5
|
Su H, Kwok KW, Cleary K, Iordachita I, Cavusoglu MC, Desai JP, Fischer GS. State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions. PROCEEDINGS OF THE IEEE. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS 2022; 110:968-992. [PMID: 35756185 PMCID: PMC9231642 DOI: 10.1109/jproc.2022.3169146] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of target anatomy, surrounding tissue, and instrumentation, but there are significant challenges in harnessing it for effectively guiding interventional procedures. Challenges include the strong static magnetic field, rapidly switching magnetic field gradients, high-power radio frequency pulses, sensitivity to electrical noise, and constrained space to operate within the bore of the scanner. MRI has a number of advantages over other medical imaging modalities, including no ionizing radiation, excellent soft-tissue contrast that allows for visualization of tumors and other features that are not readily visible by other modalities, true 3-D imaging capabilities, including the ability to image arbitrary scan plane geometry or perform volumetric imaging, and capability for multimodality sensing, including diffusion, dynamic contrast, blood flow, blood oxygenation, temperature, and tracking of biomarkers. The use of robotic assistants within the MRI bore, alongside the patient during imaging, enables intraoperative MR imaging (iMRI) to guide a surgical intervention in a closed-loop fashion that can include tracking of tissue deformation and target motion, localization of instrumentation, and monitoring of therapy delivery. With the ever-expanding clinical use of MRI, MRI-compatible robotic systems have been heralded as a new approach to assist interventional procedures to allow physicians to treat patients more accurately and effectively. Deploying robotic systems inside the bore synergizes the visual capability of MRI and the manipulation capability of robotic assistance, resulting in a closed-loop surgery architecture. This article details the challenges and history of robotic systems intended to operate in an MRI environment and outlines promising clinical applications and associated state-of-the-art MRI-compatible robotic systems and technology for making this possible.
Collapse
Affiliation(s)
- Hao Su
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Ka-Wai Kwok
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong
| | - Kevin Cleary
- Children's National Health System, Washington, DC 20010 USA
| | - Iulian Iordachita
- Laboratory for Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD 21218 USA
| | - M Cenk Cavusoglu
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
| | - Jaydev P Desai
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Gregory S Fischer
- Department of Robotics Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA
| |
Collapse
|
6
|
Abstract
Among the various robotic devices that exist for urologic surgery, the most common are synergistic telemanipulator systems. Several have achieved clinical feasibility and have been licensed for use in humans: the standard da Vinci, Avatera, Hinotori, Revo-i, Senhance, Versius, and Surgenius. Handheld and hands-on synergistic systems are also clinically relevant for use in urologic surgeries, including minimally invasive and endoscopic approaches. Future trends of robotic innovation include an exploration of more robust haptic systems that offer kinesthetic and tactile feedback; miniaturization and microrobotics; enhanced visual feedback with greater magnification and higher fidelity detail; and autonomous robots.
Collapse
|
7
|
Ochoa M, Algorri JF, Roldán-Varona P, Rodríguez-Cobo L, López-Higuera JM. Recent Advances in Biomedical Photonic Sensors: A Focus on Optical-Fibre-Based Sensing. SENSORS (BASEL, SWITZERLAND) 2021; 21:6469. [PMID: 34640788 PMCID: PMC8513032 DOI: 10.3390/s21196469] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 09/21/2021] [Accepted: 09/23/2021] [Indexed: 01/22/2023]
Abstract
In this invited review, we provide an overview of the recent advances in biomedical photonic sensors within the last five years. This review is focused on works using optical-fibre technology, employing diverse optical fibres, sensing techniques, and configurations applied in several medical fields. We identified technical innovations and advancements with increased implementations of optical-fibre sensors, multiparameter sensors, and control systems in real applications. Examples of outstanding optical-fibre sensor performances for physical and biochemical parameters are covered, including diverse sensing strategies and fibre-optical probes for integration into medical instruments such as catheters, needles, or endoscopes.
Collapse
Affiliation(s)
- Mario Ochoa
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
| | - José Francisco Algorri
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
| | - Pablo Roldán-Varona
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
- CIBER-bbn, Institute of Health Carlos III, 28029 Madrid, Spain;
| | | | - José Miguel López-Higuera
- Photonics Engineering Group, University of Cantabria, 39005 Santander, Spain; (J.F.A.); (P.R.-V.)
- Instituto de Investigación Sanitaria Valdecilla (IDIVAL), 39011 Santander, Spain
- CIBER-bbn, Institute of Health Carlos III, 28029 Madrid, Spain;
| |
Collapse
|
8
|
Huang T, Li R, Li Y, Zhang X, Liao H. Augmented reality-based autostereoscopic surgical visualization system for telesurgery. Int J Comput Assist Radiol Surg 2021; 16:1985-1997. [PMID: 34363583 DOI: 10.1007/s11548-021-02463-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 07/15/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE The visualization of remote surgical scenes is the key to realizing the remote operation of surgical robots. However, current non-endoscopic surgical robot systems lack an effective visualization tool to offer sufficient surgical scene information and depth perception. METHODS We propose a novel autostereoscopic surgical visualization system integrating 3D intraoperative scene reconstruction, autostereoscopic 3D display, and augmented reality-based image fusion. The preoperative organ structure and the intraoperative surface point cloud are obtained from medical imaging and the RGB-D camera, respectively, and aligned by an automatic marker-free intraoperative registration algorithm. After registration, preoperative meshes with precalculated illumination and intraoperative textured point cloud are blended in real time. Finally, the fused image is shown on a 3D autostereoscopic display device to achieve depth perception. RESULTS A prototype of the autostereoscopic surgical visualization system was built. The system had a horizontal image resolution of 1.31 mm, a vertical image resolution of 0.82 mm, an average rendering rate of 33.1 FPS, an average registration rate of 20.5 FPS, and average registration errors of approximately 3 mm. A telesurgical robot prototype based on 3D autostereoscopic display was built. The quantitative evaluation experiments showed that our system achieved similar operational accuracy (1.79 ± 0.87 mm) as the conventional system (1.95 ± 0.71 mm), while having advantages in terms of completion time (with 34.11% reduction) and path length (with 35.87% reduction). Post-experimental questionnaires indicated that the system was user-friendly for novices and experts. CONCLUSION We propose a 3D surgical visualization system with augmented instruction and depth perception for telesurgery. The qualitative and quantitative evaluation results illustrate the accuracy and efficiency of the proposed system. Therefore, it shows great prospects in robotic surgery and telesurgery.
Collapse
Affiliation(s)
- Tianqi Huang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Ruiyang Li
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Yangxi Li
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Xinran Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Hongen Liao
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
| |
Collapse
|
9
|
Dai X, Zhang Y, Jiang J, Li B. Image-guided robots for low dose rate prostate brachytherapy: Perspectives on safety in design and use. Int J Med Robot 2021; 17:e2239. [PMID: 33689202 DOI: 10.1002/rcs.2239] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 01/27/2021] [Accepted: 01/28/2021] [Indexed: 11/06/2022]
Abstract
BACKGROUND Image-guided brachytherapy (BT) robots can be used to assist urologists during seed implantation, thereby improving therapeutic effects. However, safety issues must be considered in the design of such robots, including their structure, mechanical movements, function, materials and actuators. Previous reviews focused on image-guided prostate BT robot technology (e.g., imaging and robot navigation technology and robot system introduction); however, this review is the first time that safety issues have been investigated as part of a study on low-dose-rate (LDR) prostate BT robots. METHODS Multiple electronic databases were searched for LDR prostate BT robot articles published during the last 24 years (1996-2020), with a particular focus on two aspects of robots: safety in design and use. RESULTS We retrieved a total of 26 LDR prostate BT robots. BT robots were divided into ultrasound, computed tomography, magnetic resonance imaging and fusion-guided systems. The conditions associated with each system were then analysed to develop a set of requirements for the safety of prostate BT robots. Recommendations are also provided for future BT robot development. CONCLUSIONS The transrectal approach for prostate seed implantation is safer than the traditional transperineal approach. Research into the control of a steerable needle by the urologists and robot, the needle deflection model, and robotic automated needle changing and seed injection equipment should be pursued in a future study.
Collapse
Affiliation(s)
- Xuesong Dai
- Robotics & Engineering Research Center, Harbin University of Science and Technology, Harbin, China
| | - Yongde Zhang
- Robotics & Engineering Research Center, Harbin University of Science and Technology, Harbin, China.,Key Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin, China
| | - Jingang Jiang
- Robotics & Engineering Research Center, Harbin University of Science and Technology, Harbin, China.,Key Laboratory of Advanced Manufacturing and Intelligent Technology, Ministry of Education, Harbin University of Science and Technology, Harbin, China
| | - Bing Li
- Robotics & Engineering Research Center, Harbin University of Science and Technology, Harbin, China
| |
Collapse
|
10
|
Mendoza E, Whitney JP. A Testbed for Haptic and Magnetic Resonance Imaging-Guided Percutaneous Needle Biopsy. IEEE Robot Autom Lett 2019. [DOI: 10.1109/lra.2019.2925558] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
11
|
An Integrated Sensor-Model Approach for Haptic Feedback of Flexible Endoscopic Robots. Ann Biomed Eng 2019; 48:342-356. [PMID: 31485875 DOI: 10.1007/s10439-019-02352-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 08/27/2019] [Indexed: 12/29/2022]
Abstract
Haptic feedback for flexible endoscopic surgical robots is challenging due to space constraints for sensors and shape-dependent force hysteresis of tendon-sheath mechanisms (TSMs). This paper proposes (1) a single-axis fiber Bragg grating (FBG)-based force sensor for a TSM of a robotic arm and (2) an integrated sensor-model approach to estimate forces on other TSMs of that arm. With a robust and simple structure, a temperature-compensated sensor can be mounted on the distal sheath to measure forces applied by the TSM. This proposed sensor was integrated with a Ø4.2 mm articulated robotic arm driven by six TSMs, with a measurement error of 0.37 N in this work. The measurement from the single sensor was used to identify parameters in the force-transmission models of all other TSMs in the robot, realizing a one-sensor-for-all-distal-forces measurement method. The sensor-model approach could accurately estimate the distal force with an RMSE of 0.65 N. An animal study was carried out to demonstrate the sensor's feasibility in real-life surgery. The sensor-model approach presented a robust, space-saving, and cost-effective solution for haptic feedback of endoscopic robots without any assumption on the shapes of the robot.
Collapse
|
12
|
Kulkarni P, Sikander S, Biswas P, Frawley S, Song SE. Review of Robotic Needle Guide Systems for Percutaneous Intervention. Ann Biomed Eng 2019; 47:2489-2513. [PMID: 31372856 DOI: 10.1007/s10439-019-02319-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Accepted: 07/02/2019] [Indexed: 01/24/2023]
Abstract
Numerous research groups in the past have designed and developed robotic needle guide systems that improve the targeting accuracy and precision by either providing a physical guidance for manual insertion or enabling a complete automated intervention. Here we review systems that have been reported in the last 11 years and limited to straight line needle interventions. Most systems fall under the category of image guided systems as they either use magnetic resonance image, computed tomography, ultrasound or a combination of these modalities for real time image feedback of the intervention path being followed. Actuation and control technology along with materials used for construction are the main aspects that differentiate these systems from each other and have been reviewed here. Image compatibility test details and results are also reviewed as they are used to ensure proper functioning of these systems under the respective imaging environments. We have also reviewed needle guide systems which either don't use any image feedback or have not reported any but provide physical guidance. Throughout this paper, we provide a comprehensive review of the technological aspects and trends in the field of robotic, straight line, needle guide intervention systems.
Collapse
Affiliation(s)
- Pankaj Kulkarni
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 12760 Pegasus Dr., ENGR 1, Room 307, Orlando, FL, 32816-2450, USA
| | - Sakura Sikander
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 12760 Pegasus Dr., ENGR 1, Room 307, Orlando, FL, 32816-2450, USA
| | - Pradipta Biswas
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 12760 Pegasus Dr., ENGR 1, Room 307, Orlando, FL, 32816-2450, USA
| | - Shawn Frawley
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 12760 Pegasus Dr., ENGR 1, Room 307, Orlando, FL, 32816-2450, USA
| | - Sang-Eun Song
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 12760 Pegasus Dr., ENGR 1, Room 307, Orlando, FL, 32816-2450, USA.
| |
Collapse
|
13
|
Nedoma J, Fajkus M, Martinek R, Nazeran H. Vital Sign Monitoring and Cardiac Triggering at 1.5 Tesla: A Practical Solution by an MR-Ballistocardiography Fiber-Optic Sensor. SENSORS (BASEL, SWITZERLAND) 2019; 19:E470. [PMID: 30682784 PMCID: PMC6386836 DOI: 10.3390/s19030470] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 01/11/2019] [Accepted: 01/21/2019] [Indexed: 12/21/2022]
Abstract
This article presents a solution for continuous monitoring of both respiratory rate (RR) and heart rate (HR) inside Magnetic Resonance Imaging (MRI) environments by a novel ballistocardiography (BCG) fiber-optic sensor. We designed and created a sensor based on the Fiber Bragg Grating (FBG) probe encapsulated inside fiberglass (fiberglass is a composite material made up of glass fiber, fabric, and cured synthetic resin). Due to this, the encapsulation sensor is characterized by very small dimensions (30 × 10 × 0.8 mm) and low weight (2 g). We present original results of real MRI measurements (conventionally most used 1.5 T MR scanner) involving ten volunteers (six men and four women) by performing conventional electrocardiography (ECG) to measure the HR and using a Pneumatic Respiratory Transducer (PRT) for RR monitoring. The acquired sensor data were compared against real measurements using the objective Bland⁻Altman method, and the functionality of the sensor was validated (95.36% of the sensed values were within the ±1.96 SD range for the RR determination and 95.13% of the values were within the ±1.96 SD range for the HR determination) by this means. The accuracy of this sensor was further characterized by a relative error below 5% (4.64% for RR and 4.87% for HR measurements). The tests carried out in an MRI environment demonstrated that the presence of the FBG sensor in the MRI scanner does not affect the quality of this imaging modality. The results also confirmed the possibility of using the sensor for cardiac triggering at 1.5 T (for synchronization and gating of cardiovascular magnetic resonance) and for cardiac triggering when a Diffusion Weighted Imaging (DWI) is used.
Collapse
Affiliation(s)
- Jan Nedoma
- Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Marcel Fajkus
- Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Radek Martinek
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 17 Listopadu 15, 70833 Ostrava, Czech Republic.
| | - Homer Nazeran
- Department of Metallurgical, Materials and Biomedical Engineering, University of Texas El Paso, 500 W University Ave, El Paso, TX 79968, USA.
| |
Collapse
|
14
|
Magnetic Resonance Imaging Compatible Non-Invasive Fibre-Optic Sensors Based on the Bragg Gratings and Interferometers in the Application of Monitoring Heart and Respiration Rate of the Human Body: A Comparative Study. SENSORS 2018; 18:s18113713. [PMID: 30384506 PMCID: PMC6263944 DOI: 10.3390/s18113713] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 10/23/2018] [Accepted: 10/29/2018] [Indexed: 11/17/2022]
Abstract
The publication presents a comparative study of two fibre-optic sensors in the application of heart rate (HR) and respiratory rate (RR) monitoring of the human body. After consultation with clinical practitioners, two types of non-invasive measuring and analysis systems based on fibre Bragg grating (FBG) and fibre-optic interferometer (FOI) have been designed and assembled. These systems use probes (both patent pending) that have been encapsulated in the bio-compatible polydimethylsiloxane (PMDS). The main advantage of PDMS is that it is electrically non-conductive and, as well as optical fibres, has low permeability. The initial verification measurement of the system designed was performed on four subjects in a harsh magnetic resonance (MR) environment under the supervision of a senior radiology assistant. A follow-up comparative study was conducted, upon a consent of twenty volunteers, in a laboratory environment with a minimum motion load and discussed with a head doctor of the Radiodiagnostic Institute. The goal of the laboratory study was to perform measurements that would simulate as closely as possible the environment of harsh MR or the environment of long-term health care facilities, hospitals and clinics. Conventional HR and RR measurement systems based on ECG measurements and changes in the thoracic circumference were used as references. The data acquired was compared by the objective Bland⁻Altman (B⁻A) method and discussed with practitioners. The results obtained confirmed the functionality of the designed probes, both in the case of RR and HR measurements (for both types of B⁻A, more than 95% of the values lie within the ±1.96 SD range), while demonstrating higher accuracy of the interferometric probe (in case of the RR determination, 95.66% for the FOI probe and 95.53% for the FBG probe, in case of the HR determination, 96.22% for the FOI probe and 95.23% for the FBG probe).
Collapse
|
15
|
Abstract
Telesurgery uses wireless networking and robotic technology to allow surgeons to operate on patients who are distantly located. This technology not only benefits today’s shortage of surgeons, but it also eliminates geographical barriers that prevent timely and high-quality surgical intervention, financial burden, complications, and often risky long-distance travel. The system also provides improved surgical accuracy and ensures the safety of surgeons. In this paper, we describe the current trend of telesurgery’s innovative developments and its future.
Collapse
Affiliation(s)
- Paul J Choi
- Surgery, Seattle Science Foundation, Seattle, USA
| | - Rod J Oskouian
- Neurosurgery, Swedish Neuroscience Institute, Seattle, USA
| | - R Shane Tubbs
- Neurosurgery, Seattle Science Foundation, Seattle, USA
| |
Collapse
|
16
|
A Skull-Mounted Robot with a Compact and Lightweight Parallel Mechanism for Positioning in Minimally Invasive Neurosurgery. Ann Biomed Eng 2018; 46:1465-1478. [DOI: 10.1007/s10439-018-2037-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Accepted: 04/20/2018] [Indexed: 11/26/2022]
|
17
|
Han AK, Bae JH, Gregoriou KC, Ploch CJ, Goldman RE, Glover GH, Daniel BL, Cutkosky MR. MR-Compatible Haptic Display of Membrane Puncture in Robot-Assisted Needle Procedures. IEEE TRANSACTIONS ON HAPTICS 2018; 11:10.1109/TOH.2018.2816074. [PMID: 29993819 PMCID: PMC6296905 DOI: 10.1109/toh.2018.2816074] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Multilayer electroactive polymer films actuate a small hand-held device that can display tool tip forces during MR-guided interventions. The display produces localized skin stretch at the thumb and index fingertips. Tests confirm that the device does not significantly affect MR imaging and produces detectable stimuli in response to forces measured by a biopsy needle instrumented with optical fibers. Tests with human subjects explored robotic and teleoperated paradigms to detect when the needle contacted a membrane embedded at variable depth in a tissue phantom that approximated the properties of porcine liver. In the first case, naive users detected membranes with a 98.9% success rate as the needle was driven at fixed speed. In the second case, users with experience in needle-based procedures controlled the needle insertion and detected membranes embedded in tissue phantoms with a 98% success rate. In the second experiment, some users detected membranes with very light contact forces, but there was greater subject-to-subject variation.
Collapse
Affiliation(s)
- Amy Kyungwon Han
- Dept. of Mech. Engineering, Stanford University, Stanford, CA 94305, USA.
| | - Jung Hwa Bae
- Dept. of Mech. Engineering, Stanford University, Stanford, CA 94305, USA.
| | | | | | - Roger E. Goldman
- Dept. of Radiology, Stanford University, Stanford, CA 94305, USA. ,
| | - Gary H. Glover
- Dept. of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.
| | - Bruce L. Daniel
- Dept. of Radiology, Stanford University, Stanford, CA 94305, USA. ,
| | - Mark R. Cutkosky
- Dept. of Mech. Engineering, Stanford University, Stanford, CA 94305, USA.
| |
Collapse
|
18
|
Guo J, Jin X, Guo S. Study of the Operational Safety of a Vascular Interventional Surgical Robotic System. MICROMACHINES 2018; 9:mi9030119. [PMID: 30424053 PMCID: PMC6187718 DOI: 10.3390/mi9030119] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 03/01/2018] [Accepted: 03/06/2018] [Indexed: 12/26/2022]
Abstract
This paper proposes an operation safety early warning system based on LabView (2014, National Instruments Corporation, Austin, TX, USA) for vascular interventional surgery (VIS) robotic system. The system not only provides intuitive visual feedback information for the surgeon, but also has a safety early warning function. It is well known that blood vessels differ in their ability to withstand stress in different age groups, therefore, the operation safety early warning system based on LabView has a vascular safety threshold function that changes in real-time, which can be oriented to different age groups of patients and a broader applicable scope. In addition, the tracing performance of the slave manipulator to the master manipulator is also an important index for operation safety. Therefore, we also transformed the slave manipulator and integrated the displacement error compensation algorithm in order to improve the tracking ability of the slave manipulator to the master manipulator and reduce master–slave tracking errors. We performed experiments “in vitro” to validate the proposed system. According to previous studies, 0.12 N is the maximum force when the blood vessel wall has been penetrated. Experimental results showed that the proposed operation safety early warning system based on LabView combined with operating force feedback can effectively avoid excessive collisions between the surgical catheter and vessel wall to avoid vascular puncture. The force feedback error of the proposed system is maintained between ±20 mN, which is within the allowable safety range and meets our design requirements. Therefore, the proposed system can ensure the safety of surgery.
Collapse
Affiliation(s)
- Jian Guo
- Key Laboratory for Control Theory and Application in Complicated Systems and Biomedical Robot Laboratory, Tianjin University of Technology, Tianjin 300384, China.
| | - Xiaoliang Jin
- Key Laboratory for Control Theory and Application in Complicated Systems and Biomedical Robot Laboratory, Tianjin University of Technology, Tianjin 300384, China.
| | - Shuxiang Guo
- Key Laboratory for Control Theory and Application in Complicated Systems and Biomedical Robot Laboratory, Tianjin University of Technology, Tianjin 300384, China.
- School of Life Science, Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, The Institute of Advanced Biomedical Engineering System, Beijing Institute of Technology, Beijing 100081, China.
- Intelligent Mechanical Systems Engineering Department, Kagawa University, Takamatsu 761-0396, Japan.
| |
Collapse
|
19
|
Yang C, Xie Y, Liu S, Sun D. Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature. SENSORS 2018; 18:s18020561. [PMID: 29439539 PMCID: PMC5855056 DOI: 10.3390/s18020561] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2017] [Revised: 01/30/2018] [Accepted: 02/08/2018] [Indexed: 11/16/2022]
Abstract
Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.
Collapse
Affiliation(s)
- Chongjun Yang
- Department of Instrumental and Electrical Engineering, Xiamen University, Xiamen 361005, China.
| | - Yu Xie
- Department of Instrumental and Electrical Engineering, Xiamen University, Xiamen 361005, China.
- Shenzhen Research Institute of Xiamen University, Shenzhen 518000, China.
| | - Shuang Liu
- School of Mechanical and Power Engineer, East China University of Science and Technology, Shanghai 200237, China.
| | - Dong Sun
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
| |
Collapse
|