1
|
Dufva M. A quantitative meta-analysis comparing cell models in perfused organ on a chip with static cell cultures. Sci Rep 2023; 13:8233. [PMID: 37217582 DOI: 10.1038/s41598-023-35043-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 05/11/2023] [Indexed: 05/24/2023] Open
Abstract
As many consider organ on a chip for better in vitro models, it is timely to extract quantitative data from the literature to compare responses of cells under flow in chips to corresponding static incubations. Of 2828 screened articles, 464 articles described flow for cell culture and 146 contained correct controls and quantified data. Analysis of 1718 ratios between biomarkers measured in cells under flow and static cultures showed that the in all cell types, many biomarkers were unregulated by flow and only some specific biomarkers responded strongly to flow. Biomarkers in cells from the blood vessels walls, the intestine, tumours, pancreatic island, and the liver reacted most strongly to flow. Only 26 biomarkers were analysed in at least two different articles for a given cell type. Of these, the CYP3A4 activity in CaCo2 cells and PXR mRNA levels in hepatocytes were induced more than two-fold by flow. Furthermore, the reproducibility between articles was low as 52 of 95 articles did not show the same response to flow for a given biomarker. Flow showed overall very little improvements in 2D cultures but a slight improvement in 3D cultures suggesting that high density cell culture may benefit from flow. In conclusion, the gains of perfusion are relatively modest, larger gains are linked to specific biomarkers in certain cell types.
Collapse
Affiliation(s)
- Martin Dufva
- Department of Health Technology, Technical University of Denmark, 2800, Kgs Lyngby, Denmark.
| |
Collapse
|
2
|
Cantoni F, Werr G, Barbe L, Porras AM, Tenje M. A microfluidic chip carrier including temperature control and perfusion system for long-term cell imaging. HARDWAREX 2021; 10:e00245. [PMID: 35607686 PMCID: PMC9123440 DOI: 10.1016/j.ohx.2021.e00245] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 10/26/2021] [Accepted: 10/30/2021] [Indexed: 06/03/2023]
Abstract
Microfluidic devices are widely used for biomedical applications but there is still a lack of affordable, reliable and user-friendly systems for transferring microfluidic chips from an incubator to a microscope while maintaining physiological conditions when performing microscopy. The presented carrier represents a cost-effective option for sustaining environmental conditions of microfluidic chips in combination with minimizing the device manipulation required for reagent injection, media exchange or sample collection. The carrier, which has the outer dimension of a standard well plate size, contains an integrated perfusion system that can recirculate the media using piezo pumps, operated in either continuous or intermittent modes (50-1000 µl/min). Furthermore, a film resistive heater made from 37 µm-thick copper wires, including temperature feedback control, was used to maintain the microfluidic chip temperature at 37 °C when outside the incubator. The heater characterisation showed a uniform temperature distribution along the chip channel for perfusion flow rates up to 10 µl/min. To demonstrate the feasibility of our platform for long term cell culture monitoring, mouse brain endothelial cells (bEnd.3) were repeatedly monitored for a period of 10 days, demonstrating a system with both the versatility and the potential for long imaging in microphysiological system cell cultures.
Collapse
|
3
|
Larsen JB, Taebnia N, Dolatshahi-Pirouz A, Eriksen AZ, Hjørringgaard C, Kristensen K, Larsen NW, Larsen NB, Marie R, Mündler AK, Parhamifar L, Urquhart AJ, Weller A, Mortensen KI, Flyvbjerg H, Andresen TL. Imaging therapeutic peptide transport across intestinal barriers. RSC Chem Biol 2021; 2:1115-1143. [PMID: 34458827 PMCID: PMC8341777 DOI: 10.1039/d1cb00024a] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Accepted: 06/09/2021] [Indexed: 12/14/2022] Open
Abstract
Oral delivery is a highly preferred method for drug administration due to high patient compliance. However, oral administration is intrinsically challenging for pharmacologically interesting drug classes, in particular pharmaceutical peptides, due to the biological barriers associated with the gastrointestinal tract. In this review, we start by summarizing the pharmacological performance of several clinically relevant orally administrated therapeutic peptides, highlighting their low bioavailabilities. Thus, there is a strong need to increase the transport of peptide drugs across the intestinal barrier to realize future treatment needs and further development in the field. Currently, progress is hampered by a lack of understanding of transport mechanisms that govern intestinal absorption and transport of peptide drugs, including the effects of the permeability enhancers commonly used to mediate uptake. We describe how, for the past decades, mechanistic insights have predominantly been gained using functional assays with end-point read-out capabilities, which only allow indirect study of peptide transport mechanisms. We then focus on fluorescence imaging that, on the other hand, provides opportunities to directly visualize and thus follow peptide transport at high spatiotemporal resolution. Consequently, it may provide new and detailed mechanistic understanding of the interplay between the physicochemical properties of peptides and cellular processes; an interplay that determines the efficiency of transport. We review current methodology and state of the art in the field of fluorescence imaging to study intestinal barrier transport of peptides, and provide a comprehensive overview of the imaging-compatible in vitro, ex vivo, and in vivo platforms that currently are being developed to accelerate this emerging field of research.
Collapse
Affiliation(s)
- Jannik Bruun Larsen
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Nayere Taebnia
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Alireza Dolatshahi-Pirouz
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Anne Zebitz Eriksen
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Claudia Hjørringgaard
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Kasper Kristensen
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Nanna Wichmann Larsen
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Niels Bent Larsen
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Rodolphe Marie
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Ann-Kathrin Mündler
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Ladan Parhamifar
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Andrew James Urquhart
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Arjen Weller
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Kim I Mortensen
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Henrik Flyvbjerg
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| | - Thomas Lars Andresen
- Center for Intestinal Absorption and Transport of Biopharmaceuticals, Department of Health Technology, Technical University of Denmark DK-2800, Kgs. Lyngby Denmark
| |
Collapse
|
4
|
Hochstetter A. Lab-on-a-Chip Technologies for the Single Cell Level: Separation, Analysis, and Diagnostics. MICROMACHINES 2020; 11:E468. [PMID: 32365567 PMCID: PMC7281269 DOI: 10.3390/mi11050468] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Revised: 04/25/2020] [Accepted: 04/25/2020] [Indexed: 12/14/2022]
Abstract
In the last three decades, microfluidics and its applications have been on an exponential rise, including approaches to isolate rare cells and diagnose diseases on the single-cell level. The techniques mentioned herein have already had significant impacts in our lives, from in-the-field diagnosis of disease and parasitic infections, through home fertility tests, to uncovering the interactions between SARS-CoV-2 and their host cells. This review gives an overview of the field in general and the most notable developments of the last five years, in three parts: 1. What can we detect? 2. Which detection technologies are used in which setting? 3. How do these techniques work? Finally, this review discusses potentials, shortfalls, and an outlook on future developments, especially in respect to the funding landscape and the field-application of these chips.
Collapse
Affiliation(s)
- Axel Hochstetter
- Experimentalphysik, Universität des Saarlandes, D-66123 Saarbrücken, Germany
| |
Collapse
|
5
|
Varma S, Voldman J. Caring for cells in microsystems: principles and practices of cell-safe device design and operation. LAB ON A CHIP 2018; 18:3333-3352. [PMID: 30324208 PMCID: PMC6254237 DOI: 10.1039/c8lc00746b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Microfluidic device designers and users continually question whether cells are 'happy' in a given microsystem or whether they are perturbed by micro-scale technologies. This issue is normally brought up by engineers building platforms, or by external reviewers (academic or commercial) comparing multiple technological approaches to a problem. Microsystems can apply combinations of biophysical and biochemical stimuli that, although essential to device operation, may damage cells in complex ways. However, assays to assess the impact of microsystems upon cells have been challenging to conduct and have led to subjective interpretation and evaluation of cell stressors, hampering development and adoption of microsystems. To this end, we introduce a framework that defines cell health, describes how device stimuli may stress cells, and contrasts approaches to measure cell stress. Importantly, we provide practical guidelines regarding device design and operation to minimize cell stress, and recommend a minimal set of quantitative assays that will enable standardization in the assessment of cell health in diverse devices. We anticipate that as microsystem designers, reviewers, and end-users enforce such guidelines, we as a community can create a set of essential principles that will further the adoption of such technologies in clinical, translational and commercial applications.
Collapse
Affiliation(s)
- Sarvesh Varma
- Department of Electrical Engineering and Computer Science
, Massachusetts Institute of Technology
,
77 Massachusetts Avenue, Room 36-824
, Cambridge
, USA
.
; Fax: +617 258 5846
; Tel: +617 253 1583
| | - Joel Voldman
- Department of Electrical Engineering and Computer Science
, Massachusetts Institute of Technology
,
77 Massachusetts Avenue, Room 36-824
, Cambridge
, USA
.
; Fax: +617 258 5846
; Tel: +617 253 1583
| |
Collapse
|
6
|
Reprogramming the Stem Cell Behavior by Shear Stress and Electric Field Stimulation: Lab-on-a-Chip Based Biomicrofluidics in Regenerative Medicine. REGENERATIVE ENGINEERING AND TRANSLATIONAL MEDICINE 2018. [DOI: 10.1007/s40883-018-0071-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
7
|
Mäki AJ, Verho J, Kreutzer J, Ryynänen T, Rajan D, Pekkanen-Mattila M, Ahola A, Hyttinen J, Aalto-Setälä K, Lekkala J, Kallio P. A Portable Microscale Cell Culture System with Indirect Temperature Control. SLAS Technol 2018; 23:566-579. [PMID: 29723086 DOI: 10.1177/2472630318768710] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
A physiologically relevant environment is essential for successful long-term cell culturing in vitro. Precise control of temperature, one of the most crucial environmental parameters in cell cultures, increases the fidelity and repeatability of the experiments. Unfortunately, direct temperature measurement can interfere with the cultures or prevent imaging of the cells. Furthermore, the assessment of dynamic temperature variations in the cell culture area is challenging with the methods traditionally used for measuring temperature in cell culture systems. To overcome these challenges, we integrated a microscale cell culture environment together with live-cell imaging and a precise local temperature control that is based on an indirect measurement. The control method uses a remote temperature measurement and a mathematical model for estimating temperature at the desired area. The system maintained the temperature at 37±0.3 °C for more than 4 days. We also showed that the system precisely controls the culture temperature during temperature transients and compensates for the disturbance when changing the cell cultivation medium, and presented the portability of the heating system. Finally, we demonstrated a successful long-term culturing of human induced stem cell-derived beating cardiomyocytes, and analyzed their beating rates at different temperatures.
Collapse
Affiliation(s)
- Antti-Juhana Mäki
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Jarmo Verho
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Joose Kreutzer
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Tomi Ryynänen
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Dhanesh Rajan
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Mari Pekkanen-Mattila
- 2 BioMediTech Institute and Faculty of Medicine and Life Sciences, University of Tampere, Tampere, Finland
| | - Antti Ahola
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Jari Hyttinen
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Katriina Aalto-Setälä
- 2 BioMediTech Institute and Faculty of Medicine and Life Sciences, University of Tampere, Tampere, Finland.,3 Heart Hospital, Tampere University Hospital, Tampere, Finland
| | - Jukka Lekkala
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| | - Pasi Kallio
- 1 BioMediTech Institute and Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland
| |
Collapse
|
8
|
Nieto D, McGlynn P, de la Fuente M, Lopez-Lopez R, O'connor GM. Laser microfabrication of a microheater chip for cell culture outside a cell incubator. Colloids Surf B Biointerfaces 2017; 154:263-269. [PMID: 28347948 DOI: 10.1016/j.colsurfb.2017.03.043] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Revised: 02/24/2017] [Accepted: 03/20/2017] [Indexed: 02/06/2023]
Abstract
Microfluidic chips have demonstrated their significant application potentials in microbiological processing and chemical reactions, with the goal of developing monolithic and compact chip-sized multifunctional systems. Heat generation and thermal control are critical in some of the biochemical processes. The paper presents a laser direct-write technique for rapid prototyping and manufacturing of microheater chips and its applicability for lab-on-a-chip cell culture outside a cell incubator. The aim of the microheater is to take the role of conventional incubators for cell culture for facilitating microscopic observation and/or other online monitoring activities during cell culture and provides portability of cell culture operation. Microheaters (5mm×5mm) have been successfully fabricated on soda-lime glass substrates covered with aluminium layer of thickness 120nm. Experimental results show that the microheaters exhibit good performance in temperature rise and decay characteristics, with localized heating at targeted spatial domains. These microheaters were suitable for a maximum long-term operation temperature of 120°C and validated for operation at 37°C for 48h. Results demonstrated that the microheaters are suitable for the culture of immortalised cell lines. The growth and viability of SW480 colon adenocarcinoma cells cultured the developed microheater chip were comparable to the results obtained in a conventional cell incubator.
Collapse
Affiliation(s)
- Daniel Nieto
- Microoptics and GRIN Optics Group, Applied Physics Department, Faculty of Physics, University of Santiago de Compostela, Santiago de Compostela, E15782 Spain; School of Physics, National Centre for Laser Applications, National University of Ireland, University Road, Galway, Ireland.
| | - Peter McGlynn
- School of Physics, National Centre for Laser Applications, National University of Ireland, University Road, Galway, Ireland
| | - María de la Fuente
- Translational Medical Oncology Group, Health Research Institute of Santiago de Compostela (IDIS), SERGAS, 15706 Santiago de Compostela, Spain
| | - Rafael Lopez-Lopez
- Translational Medical Oncology Group, Health Research Institute of Santiago de Compostela (IDIS), SERGAS, 15706 Santiago de Compostela, Spain
| | - Gerard M O'connor
- School of Physics, National Centre for Laser Applications, National University of Ireland, University Road, Galway, Ireland
| |
Collapse
|
9
|
Hochstetter A, Stellamanns E, Deshpande S, Uppaluri S, Engstler M, Pfohl T. Microfluidics-based single cell analysis reveals drug-dependent motility changes in trypanosomes. LAB ON A CHIP 2015; 15:1961-8. [PMID: 25756872 DOI: 10.1039/c5lc00124b] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We present a single cell viability assay, based on chemical gradient microfluidics in combination with optical micromanipulation. Here, we used this combination to in situ monitor the effects of drugs and chemicals on the motility of the flagellated unicellular parasite Trypanosoma brucei; specifically, the local cell velocity and the mean squared displacement (MSD) of the cell trajectories. With our method, we are able to record in situ cell fixation by glutaraldehyde, and to quantify the critical concentration of 2-deoxy-d-glucose required to completely paralyze trypanosomes. In addition, we detected and quantified the impact on cell propulsion and energy generation at much lower 2-deoxy-d-glucose concentrations. Our microfluidics-based approach advances fast cell-based drug testing in a way that allows us to distinguish cytocidal from cytostatic drug effects, screen effective dosages, and investigate the impact on cell motility of drugs and chemicals. Using suramin, we could reveal the impact of the widely used drug on trypanosomes: suramin lowers trypanosome motility and induces cell-lysis after endocytosis.
Collapse
Affiliation(s)
- Axel Hochstetter
- Department of Chemistry, University of Basel, 4056 Basel, Switzerland.
| | | | | | | | | | | |
Collapse
|
10
|
Controlled delivery of hollow corn protein nanoparticles via non-toxic crosslinking: in vivo and drug loading study. Biomed Microdevices 2015; 17:8. [DOI: 10.1007/s10544-014-9926-5] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
11
|
Rodriguez-Rodriguez R, Muñoz-Berbel X, Demming S, Büttgenbach S, Herrera MD, Llobera A. Cell-based microfluidic device for screening anti-proliferative activity of drugs in vascular smooth muscle cells. Biomed Microdevices 2013; 14:1129-40. [PMID: 22773184 DOI: 10.1007/s10544-012-9679-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
This paper presents a microfluidic device consisting of five parallel microchambers with integrated readout-grid for the screening of anti-proliferative activity of drugs in vascular smooth muscle cells (VSMC). A two-level SU-8 master was fabricated and replicated with poly(dimethylsiloxane), PDMS, using standard soft-lithographic methods. The relative small height (4-10 μm) of the integrated grid allowed the identification of single-cells or cell groups and the monitoring of their motility, morphology and size with time, without disturbing their proliferation pattern. This is of particular interest when considering VSMC which, apart of being crucial in the atherosclerotic process, do not proliferate in a single layer but in a non-homogenous hill and valley phenotype. The performance of the microfluidic device has been validated by comparison with conventional culturing methods, proving that the cell proliferation remains unaffected by the microchamber structure (with the integrated grid) and the experimental conditions. Finally, the microfluidic device was also used to evaluate the anti-proliferative activity of curcumin and colchicine in VSMC. With this cellular type, the anti-proliferative activity of curcumin (IC(50) =35 ± 5 μM) was found to be much lower than colchicine (IC(50) =3.2 ± 1.2 μM). These results demonstrate the good performance of the microfluidic device in the evaluation of the anti-proliferative activity (or cytotoxicity) of drugs.
Collapse
Affiliation(s)
- R Rodriguez-Rodriguez
- School of Pharmacy, Department of Pharmacology, Universidad de Sevilla, Sevilla, Spain
| | | | | | | | | | | |
Collapse
|
12
|
Tehranirokh M, Kouzani AZ, Francis PS, Kanwar JR. Microfluidic devices for cell cultivation and proliferation. BIOMICROFLUIDICS 2013; 7:51502. [PMID: 24273628 PMCID: PMC3829894 DOI: 10.1063/1.4826935] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Accepted: 09/24/2013] [Indexed: 05/07/2023]
Abstract
Microfluidic technology provides precise, controlled-environment, cost-effective, compact, integrated, and high-throughput microsystems that are promising substitutes for conventional biological laboratory methods. In recent years, microfluidic cell culture devices have been used for applications such as tissue engineering, diagnostics, drug screening, immunology, cancer studies, stem cell proliferation and differentiation, and neurite guidance. Microfluidic technology allows dynamic cell culture in microperfusion systems to deliver continuous nutrient supplies for long term cell culture. It offers many opportunities to mimic the cell-cell and cell-extracellular matrix interactions of tissues by creating gradient concentrations of biochemical signals such as growth factors, chemokines, and hormones. Other applications of cell cultivation in microfluidic systems include high resolution cell patterning on a modified substrate with adhesive patterns and the reconstruction of complicated tissue architectures. In this review, recent advances in microfluidic platforms for cell culturing and proliferation, for both simple monolayer (2D) cell seeding processes and 3D configurations as accurate models of in vivo conditions, are examined.
Collapse
|
13
|
Titmarsh DM, Chen H, Wolvetang EJ, Cooper-White JJ. Arrayed cellular environments for stem cells and regenerative medicine. Biotechnol J 2012; 8:167-79. [PMID: 22890848 DOI: 10.1002/biot.201200149] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 07/02/2012] [Accepted: 07/17/2012] [Indexed: 12/26/2022]
Abstract
The behavior and composition of both multipotent and pluripotent stem cell populations are exquisitely controlled by a complex, spatiotemporally variable interplay of physico-chemical, extracellular matrix, cell-cell interaction, and soluble factor cues that collectively define the stem cell niche. The push for stem cell-based regenerative medicine models and therapies has fuelled demands for increasingly accurate cellular environmental control and enhanced experimental throughput, driving an evolution of cell culture platforms away from conventional culture formats toward integrated systems. Arrayed cellular environments typically provide a set of discrete experimental elements with variation of one or several classes of stimuli across elements of the array. These are based on high-content/high-throughput detection, small sample volumes, and multiplexing of environments to increase experimental parameter space, and can be used to address a range of biological processes at the cell population, single-cell, or subcellular level. Arrayed cellular environments have the capability to provide an unprecedented understanding of the molecular and cellular events that underlie expansion and specification of stem cell and therapeutic cell populations, and thus generate successful regenerative medicine outcomes. This review focuses on recent key developments of arrayed cellular environments and their contribution and potential in stem cells and regenerative medicine.
Collapse
Affiliation(s)
- Drew M Titmarsh
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, St. Lucia, Australia
| | | | | | | |
Collapse
|
14
|
A self-contained, programmable microfluidic cell culture system with real-time microscopy access. Biomed Microdevices 2012; 14:385-99. [PMID: 22160447 DOI: 10.1007/s10544-011-9615-6] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Utilizing microfluidics is a promising way for increasing the throughput and automation of cell biology research. We present a complete self-contained system for automated cell culture and experiments with real-time optical read-out. The system offers a high degree of user-friendliness, stability due to simple construction principles and compactness for integration with standard instruments. Furthermore, the self-contained system is highly portable enabling transfer between work stations such as laminar flow benches, incubators and microscopes. Accommodation of 24 individual inlet channels enables the system to perform parallel, programmable and multiconditional assays on a single chip. A modular approach provides system versatility and allows many different chips to be used dependent upon application. We validate the system's performance by demonstrating on-chip passive switching and mixing by peristaltically driven flows. Applicability for biological assays is demonstrated by on-chip cell culture including on-chip transfection and temporally programmable gene expression.
Collapse
|
15
|
Takano A, Ogawa T, Tanaka M, Futai N. On-chip incubation system for long-term microfluidic cell culture. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:8404-7. [PMID: 22256297 DOI: 10.1109/iembs.2011.6092073] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We demonstrate the use of a microfluidic cell culture chip with Braille pin-driven pumping, capable of on-chip CO2 incubation that does not require an external chamber or gas supply. The proposed chip consists of a poly(dimethylsiloxane)(PDMS)-made microfluidic chip, flip-mounted on a glass slide, that contains a nested pair of cell culture media reservoirs and water-jacket, insulated by a permeable PDMS wall. By using 0.8 M sodium bicarbonate with 65 mM sodium carbonate as the water-jacket and placing on a 37 °C surface, the chip maintained osmolality shift and the pCO2 in the media reservoir stabilized within < 3 mmol/kg and 5.0% ± 0.2% over at least 24 hours. The incubation capabilities were demonstrated through microfluidic culture of CV-1 epithelial cells under an inverted microscope for at least 12 days.
Collapse
Affiliation(s)
- Atsushi Takano
- School of Science and Engineering, Tokyo Denki University, Saitama 350-0394, Japan.
| | | | | | | |
Collapse
|
16
|
Kobayashi K, Cheng D, Huynh M, Ratinac KR, Thordarson P, Braet F. Imaging fluorescently labeled complexes by means of multidimensional correlative light and transmission electron microscopy: practical considerations. Methods Cell Biol 2012; 111:1-20. [PMID: 22857920 DOI: 10.1016/b978-0-12-416026-2.00001-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
These days the common ground between structural biology and molecular biology continues to grow thanks to the biomolecular insights offered by correlative microscopy, even though the vision of combining insights from different imaging tools has been around for nearly four decades. The use of correlative imaging methods to dissect the cell's internal structure is progressing faster than ever as shown by the boom in the number of methodological approaches available for correlative microscopy studies, each designed to address a specific scientific question. In this chapter, we will present a relatively straightforward approach to combining information from fluorescence microscopy and electron microscopy at the supramolecular level. The method combines live-cell and/or confocal laser microscopy with classical sample preparation for transmission electron microscopy (TEM), thereby allowing the integration of dynamic details of subcellular processes with insights about the organelles and molecular machinery involved. We illustrate the applicability of this multidimensional correlative microscopy approach on cultured Caco-2 colorectal cancer cells exposed to fluorescently labeled cisplatin, and discuss how these methods can deepen our understanding of key cellular processes, such as drug uptake and cell fate.
Collapse
Affiliation(s)
- K Kobayashi
- Australian Centre for Microscopy & Microanalysis, The University of Sydney, NSW 2006, Australia
| | | | | | | | | | | |
Collapse
|
17
|
Lin L, Wang SS, Wu MH, Oh-Yang CC. Development of an integrated microfluidic perfusion cell culture system for real-time microscopic observation of biological cells. SENSORS 2011; 11:8395-411. [PMID: 22164082 PMCID: PMC3231477 DOI: 10.3390/s110908395] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2011] [Revised: 08/26/2011] [Accepted: 08/26/2011] [Indexed: 11/16/2022]
Abstract
This study reports an integrated microfluidic perfusion cell culture system consisting of a microfluidic cell culture chip, and an indium tin oxide (ITO) glass-based microheater chip for micro-scale perfusion cell culture, and its real-time microscopic observation. The system features in maintaining both uniform, and stable chemical or thermal environments, and providing a backflow-free medium pumping, and a precise thermal control functions. In this work, the performance of the medium pumping scheme, and the ITO glass microheater were experimentally evaluated. Results show that the medium delivery mechanism was able to provide pumping rates ranging from 15.4 to 120.0 μL·min−1. In addition, numerical simulation and experimental evaluation were conducted to verify that the ITO glass microheater was capable of providing a spatially uniform thermal environment, and precise temperature control with a mild variation of ±0.3 °C. Furthermore, a perfusion cell culture was successfully demonstrated, showing the cultured cells were kept at high cell viability of 95 ± 2%. In the process, the cultured chondrocytes can be clearly visualized microscopically. As a whole, the proposed cell culture system has paved an alternative route to carry out real-time microscopic observation of biological cells in a simple, user-friendly, and low cost manner.
Collapse
Affiliation(s)
- Lung Lin
- Department of Mechanical and Automation Engineering, I-Shou University, Kaohsiung 82445, Taiwan; E-Mails: (J.-L.L.); (C.-C.O.Y.)
| | - Shih-Siou Wang
- Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan 333, Taiwan; E-Mail:
| | - Min-Hsien Wu
- Graduate Institute of Biochemical and Biomedical Engineering, Chang Gung University, Taoyuan 333, Taiwan
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +886-3211-8800 ext 3599; Fax: +886-3211-8668
| | - Chih-Chin Oh-Yang
- Department of Mechanical and Automation Engineering, I-Shou University, Kaohsiung 82445, Taiwan; E-Mails: (J.-L.L.); (C.-C.O.Y.)
| |
Collapse
|
18
|
Li X, Liu L, Wang L, Kamei KI, Yuan Q, Zhang F, Shi J, Kusumi A, Xie M, Zhao Z, Chen Y. Integrated and diffusion-based micro-injectors for open access cell assays. LAB ON A CHIP 2011; 11:2612-7. [PMID: 21655556 DOI: 10.1039/c1lc20258h] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Currently, most microfluidic devices are fabricated with embedded micro-channels and other elements in a close form with outward connections. Although much functionality has been demonstrated and a large number of applications have been developed, they are not easy for routine operation in biology laboratories where most in vitro cell processing still relies on the use of culture dishes, glass slides, multi-well plates, tubes, pipettes, etc. We report here an open access device which consists of an array of isolated micro-channels plated on a large culture surface, each of them having tiny nozzles for localized drug delivery. In a diffusion dominant regime, steady gradients of molecule concentration could be obtained and varied by changing the flow rate inside the micro-channels. As assay examples, cell staining and drug-induced cell apoptosis were demonstrated, showing fast cell responses in close proximity of the nozzles.
Collapse
Affiliation(s)
- Xin Li
- Ecole Normale Supérieure, CNRS-ENS-UPMC UMR 8640, 24 rue Lhomond, 75005, Paris, France
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Riahi R, Mach KE, Mohan R, Liao JC, Wong PK. Molecular detection of bacterial pathogens using microparticle enhanced double-stranded DNA probes. Anal Chem 2011; 83:6349-54. [PMID: 21718053 DOI: 10.1021/ac2012575] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Rapid, specific, and sensitive detection of bacterial pathogens is essential toward clinical management of infectious diseases. Traditional approaches for pathogen detection, however, often require time-intensive bacterial culture and amplification procedures. Herein, a microparticle enhanced double-stranded DNA probe is demonstrated for rapid species-specific detection of bacterial 16S rRNA. In this molecular assay, the binding of the target sequence to the fluorophore conjugated probe thermodynamically displaces the quencher probe and allows the fluorophore to fluoresce. By incorporation of streptavidin-coated microparticles to localize the biotinylated probes, the sensitivity of the assay can be improved by 3 orders of magnitude. The limit of detection of the assay is as few as eight bacteria without target amplification and is highly specific against other common pathogens. Its applicability toward clinical diagnostics is demonstrated by directly identifying bacterial pathogens in urine samples from patients with urinary tract infections.
Collapse
Affiliation(s)
- Reza Riahi
- Department of Aerospace and Mechanical Engineering, University of Arizona, Tucson, Arizona 85721, United States
| | | | | | | | | |
Collapse
|
20
|
Fischer R, Steinert S, Fröber U, Voges D, Stubenrauch M, Hofmann G, Witte H. Cell cultures in microsystems: Biocompatibility aspects. Biotechnol Bioeng 2010; 108:687-93. [DOI: 10.1002/bit.22951] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2010] [Revised: 09/07/2010] [Accepted: 09/08/2010] [Indexed: 11/05/2022]
|
21
|
Salieb-Beugelaar GB, Simone G, Arora A, Philippi A, Manz A. Latest developments in microfluidic cell biology and analysis systems. Anal Chem 2010; 82:4848-64. [PMID: 20462184 DOI: 10.1021/ac1009707] [Citation(s) in RCA: 174] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
22
|
Albrecht DR, Underhill GH, Resnikoff J, Mendelson A, Bhatia SN, Shah JV. Microfluidics-integrated time-lapse imaging for analysis of cellular dynamics. Integr Biol (Camb) 2010; 2:278-87. [PMID: 20532320 PMCID: PMC4040291 DOI: 10.1039/b923699f] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
An understanding of the mechanisms regulating cellular responses has recently been augmented by innovations enabling the observation of phenotypes at high spatio-temporal resolution. Technologies such as microfluidics have sought to expand the throughput of these methods, although assimilation with advanced imaging strategies has been limited. Here, we describe the pairing of high resolution time-lapse imaging with microfluidic multiplexing for the analysis of cellular dynamics, utilizing a design selected for facile fabrication and operation, and integration with microscopy instrumentation. This modular, medium-throughput platform enables the long-term imaging of living cells at high numerical aperture (via oil immersion) by using a conserved 96-well, approximately 6 x 5 mm(2) imaging area with a variable input/output channel design chosen for the number of cell types and microenvironments under investigation. In the validation of this system, we examined fundamental features of cell cycle progression, including mitotic kinetics and spindle orientation dynamics, through the high-resolution parallel analysis of model cell lines subjected to anti-mitotic agents. We additionally explored the self-renewal kinetics of mouse embryonic stem cells, and demonstrate the ability to dynamically assess and manipulate stem cell proliferation, detect rare cell events, and measure extended time-scale correlations. We achieved an experimental throughput of >900 cells/experiment, each observed at >40x magnification for up to 120 h. Overall, these studies illustrate the capacity to probe cellular functions and yield dynamic information in time and space through the integration of a simple, modular, microfluidics-based imaging platform.
Collapse
Affiliation(s)
- Dirk R. Albrecht
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA
| | | | | | - Avital Mendelson
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA
| | - Sangeeta N. Bhatia
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA
- Division of Medicine, Brigham and Women’s Hospital, Boston, MA
- The Howard Hughes Medical Institute, Massachusetts Institute of Technology, Cambridge, MA
| | - Jagesh V. Shah
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA
- Renal Division, Brigham and Women’s Hospital, Boston, MA
- Department of Systems Biology, Harvard Medical School, Boston, MA
| |
Collapse
|