1
|
An K, Zhang F, Ouyang W, Pan X. Blood flow dynamics in the ascending aorta of patients with bicuspid aortic valve before and after transcatheter aortic valve replacement: a computational fluid dynamics study. BMC Cardiovasc Disord 2024; 24:717. [PMID: 39702010 DOI: 10.1186/s12872-024-04394-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Accepted: 12/02/2024] [Indexed: 12/21/2024] Open
Abstract
BACKGROUND Abnormal blood flow patterns are known to contribute to the ascending aortic dilation in patients with bicuspid aortic valve (BAV). The present study elucidated the blood flow characteristics in the dilated ascending aorta before and after transcatheter aortic valve replacement (TAVR) using computational fluid dynamics (CFD) analysis. METHODS We performed CFD analysis in three BAV patients with ascending aortic dilation (maximum diameter ≥ 45 mm) who underwent TAVR. The blood flow streamline was visualized to evaluate the pre- and post-operative flow velocity, severity of vortex and helix, and wall shear stress (WSS) in the ascending aorta. RESULTS Before the procedure, all three patients showed abnormal blood flow patterns, with vortex and helix in the ascending aorta. Regionally elevated WSS was also observed in the lateral or posterior ascending aortic wall (16.7 Pa, 12.2 Pa, and 14.5 Pa in patient 1, 2, and 3, respectively). After the procedure, the blood flow patterns significantly improved, and the maximum WSS also decreased (4.2 Pa, 1.1 Pa, and 3.2 Pa in patient 1, 2, and 3, respectively). CONCLUSION Abnormal blood flow patterns and WSS appeared to improve after TAVR in BAV patients with ascending aortic dilation. The impact on the long-term aortic growth rate and the incidence of aortic dissection requires further studies. TRIAL REGISTRATION Changes of Ascending Aortic Diameter in Patients Undergoing Transcatheter Aortic Valve Replacement. CLINICALTRIAL gov number NCT05739253. Trial registration date 20,230,212.
Collapse
Affiliation(s)
- Kang An
- Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
- National Health Commission Key Laboratory of Cardiovascular Regeneration Medicine, Beijing, China
- Key Laboratory of Innovative Cardiovascular Devices, Chinese Academy of Medical Sciences, Beijing, China
- National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Fengwen Zhang
- Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
- National Health Commission Key Laboratory of Cardiovascular Regeneration Medicine, Beijing, China
- Key Laboratory of Innovative Cardiovascular Devices, Chinese Academy of Medical Sciences, Beijing, China
- National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Wenbin Ouyang
- Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
- National Health Commission Key Laboratory of Cardiovascular Regeneration Medicine, Beijing, China
- Key Laboratory of Innovative Cardiovascular Devices, Chinese Academy of Medical Sciences, Beijing, China
- National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Xiangbin Pan
- Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
- National Health Commission Key Laboratory of Cardiovascular Regeneration Medicine, Beijing, China.
- Key Laboratory of Innovative Cardiovascular Devices, Chinese Academy of Medical Sciences, Beijing, China.
- National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences, Beijing, China.
- Department of Structural Heart Disease, Fuwai Hospital, No. 167 North Lishi Rd, Xicheng District, Beijing, China.
| |
Collapse
|
2
|
Jia Y, Khokhar AA, Pilgrim T, Costa G, Mylotte D, Sammartino S, Tomii D, Fosbøl E, Tamburino C, Kofoed KF, Barbanti M, Windecker S, Chen M, De Backer O. Incidence and predictors of continued ascending aortic dilatation after TAVI in patients with bicuspid aortic stenosis. Clin Res Cardiol 2024:10.1007/s00392-024-02545-9. [PMID: 39297943 DOI: 10.1007/s00392-024-02545-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Accepted: 09/06/2024] [Indexed: 09/21/2024]
Abstract
BACKGROUND Patients undergoing transcatheter aortic valve implantation (TAVI) for bicuspid aortic stenosis (AS) frequently present with ascending aortic (AAo) dilatation which is left untreated. The objective of this study was to study the natural progression and underlying mechanisms of AAo dilatation after TAVI for bicuspid AS. METHODS Patients with a native bicuspid AS and a baseline AAo maximum diameter > 40 mm treated by TAVI and in whom post-TAVI computed tomography (CT) scans beyond 1 year were available were included. AAo dilatation was deemed to be either continuous (≥ 2 mm increase) or stable (< 2 mm increase or decrease). Uni- and multivariate logistic regression analysis was utilized in order to identify factors associated with continuous AAo dilatation post-TAVI. RESULTS A total of 61 patients with a mean AAo maximum diameter of 45.6 ± 3.9 mm at baseline were evaluated. At a median follow-up of 2.9 years, AAo dimensions remained stable in 85% of patients. Continuous AAo dilatation was observed in 15% of patients at a rate of 1.4 mm/year. Factors associated with continuous AAo dilatation were raphe length/annulus mean diameter ratio (OR 4.09, 95% CI [1.40-16.7], p = 0.022), TAV eccentricity at the leaflet outflow level (OR 2.11, 95%CI [1.12-4.53], p = 0.031) and maximum transprosthetic gradient (OR 1.30, 95%CI [0.99-1.73], p = 0.058). CONCLUSIONS Ascending aortic dilatation in patients undergoing TAVI for bicuspid AS remains stable in the majority of patients. Factors influencing TAV stent frame geometry and function were identified to be associated with continuous AAo dilatation after TAVI; this should be confirmed in future larger cohort studies.
Collapse
Affiliation(s)
- Yuheng Jia
- The Heart Center, Rigshospitalet, Copenhagen, Denmark
- Department of Cardiology, West China Hospital, Chengdu, China
| | - Arif A Khokhar
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, London, UK
| | - Thomas Pilgrim
- Department of Cardiology and, Cardiovascular Center, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
| | - Giuliano Costa
- AOU Policlinico 'G. Rodolico-San Marco', University of Catania, Catania, Italy
| | - Darren Mylotte
- Department of Cardiology, Galway University Hospital, Galway, Ireland
| | - Sofia Sammartino
- AOU Policlinico 'G. Rodolico-San Marco', University of Catania, Catania, Italy
| | - Daijiro Tomii
- Department of Cardiology and, Cardiovascular Center, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
| | - Emil Fosbøl
- The Heart Center, Rigshospitalet, Copenhagen, Denmark
| | - Corrado Tamburino
- AOU Policlinico 'G. Rodolico-San Marco', University of Catania, Catania, Italy
| | | | | | - Stephan Windecker
- Department of Cardiology and, Cardiovascular Center, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland
| | - Mao Chen
- Department of Cardiology, West China Hospital, Chengdu, China
| | - Ole De Backer
- The Heart Center, Rigshospitalet, Copenhagen, Denmark.
| |
Collapse
|
3
|
Takahashi Y, Kamiya K, Nagai T, Tsuneta S, Oyama-Manabe N, Hamaya T, Kazui S, Yasui Y, Saiin K, Naito S, Mizuguchi Y, Takenaka S, Tada A, Ishizaka S, Kobayashi Y, Omote K, Sato T, Shingu Y, Kudo K, Wakasa S, Anzai T. Differences in blood flow dynamics between balloon- and self-expandable valves in patients with aortic stenosis undergoing transcatheter aortic valve replacement. J Cardiovasc Magn Reson 2023; 25:60. [PMID: 37880721 PMCID: PMC10601149 DOI: 10.1186/s12968-023-00970-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 09/26/2023] [Indexed: 10/27/2023] Open
Abstract
BACKGROUND The differences in pre- and early post-procedural blood flow dynamics between the two major types of bioprosthetic valves, the balloon-expandable valve (BEV) and self-expandable valve (SEV), in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR), have not been investigated. We aimed to investigate the differences in blood flow dynamics between the BEV and SEV using four-dimensional flow cardiovascular magnetic resonance (4D flow CMR). METHODS We prospectively examined 98 consecutive patients with severe AS who underwent TAVR between May 2018 and November 2021 (58 BEV and 40 SEV) after excluding those without CMR because of a contraindication, inadequate imaging from the analyses, or patients' refusal. CMR was performed in all participants before (median interval, 22 [interquartile range (IQR) 4-39] days) and after (median interval, 6 [IQR 3-6] days) TAVR. We compared the changes in blood flow patterns, wall shear stress (WSS), and energy loss (EL) in the ascending aorta (AAo) between the BEV and SEV using 4D flow CMR. RESULTS The absolute reductions in helical flow and flow eccentricity were significantly higher in the SEV group compared in the BEV group after TAVR (BEV: - 0.22 ± 0.86 vs. SEV: - 0.85 ± 0.80, P < 0.001 and BEV: - 0.11 ± 0.79 vs. SEV: - 0.50 ± 0.88, P = 0.037, respectively); there were no significant differences in vortical flow between the groups. The absolute reduction of average WSS was significantly higher in the SEV group compared to the BEV group after TAVR (BEV: - 0.6 [- 2.1 to 0.5] Pa vs. SEV: - 1.8 [- 3.5 to - 0.8] Pa, P = 0.006). The systolic EL in the AAo significantly decreased after TAVR in both the groups, while the absolute reduction was comparable between the groups. CONCLUSIONS Helical flow, flow eccentricity, and average WSS in the AAo were significantly decreased after SEV implantation compared to BEV implantation, providing functional insights for valve selection in patients with AS undergoing TAVR. Our findings offer valuable insights into blood flow dynamics, aiding in the selection of valves for patients with AS undergoing TAVR. Further larger-scale studies are warranted to confirm the prognostic significance of hemodynamic changes in these patients.
Collapse
Affiliation(s)
- Yuki Takahashi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kiwamu Kamiya
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Toshiyuki Nagai
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan.
| | - Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-Ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Noriko Oyama-Manabe
- Department of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya-Ku, Saitama-City, Saitama, 330-8503, Japan
| | - Takeshi Hamaya
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Sho Kazui
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yutaro Yasui
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kohei Saiin
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Seiichiro Naito
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yoshifumi Mizuguchi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Sakae Takenaka
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Atsushi Tada
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Suguru Ishizaka
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yuta Kobayashi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kazunori Omote
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Takuma Sato
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yasushige Shingu
- Department of Cardiovascular Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kohsuke Kudo
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-Ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Satoru Wakasa
- Department of Cardiovascular Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Toshihisa Anzai
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-Ku, Sapporo, Hokkaido, 060-8638, Japan
| |
Collapse
|
4
|
Righini P, Secchi F, Mazzaccaro D, Giese D, Galligani M, Avishay D, Capra D, Monti CB, Nano G. Four-Dimensional Flow MRI for the Evaluation of Aortic Endovascular Graft: A Pilot Study. Diagnostics (Basel) 2023; 13:2113. [PMID: 37371010 DOI: 10.3390/diagnostics13122113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 05/28/2023] [Accepted: 06/15/2023] [Indexed: 06/29/2023] Open
Abstract
We aimed to explore the feasibility of 4D flow magnetic resonance imaging (MRI) for patients undergoing thoracic aorta endovascular repair (TEVAR). We retrospectively evaluated ten patients (two female), with a mean (±standard deviation) age of 61 ± 20 years, undergoing MRI for a follow-up after TEVAR. All 4D flow examinations were performed using a 1.5-T system (MAGNETOM Aera, Siemens Healthcare, Erlangen, Germany). In addition to the standard examination protocol, a 4D flow-sensitive 3D spatial-encoding, time-resolved, phase-contrast prototype sequence was acquired. Among our cases, flow evaluation was feasible in all patients, although we observed some artifacts in 3 out of 10 patients. Three individuals displayed a reduced signal within the vessel lumen where the endograft was placed, while others presented with turbulent or increased flow. An aortic endograft did not necessarily hinder the visualization of blood flow through 4D flow sequences, although the graft could generate flow artifacts in some cases. A 4D Flow MRI may represent the ideal tool to follow up on both healthy subjects deemed to be at an increased risk based on their anatomical characteristics or patients submitted to TEVAR for whom a surveillance protocol with computed tomography angiography would be cumbersome and unjustified.
Collapse
Affiliation(s)
- Paolo Righini
- Operative Unit of Vascular & Endovascular Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese, Italy
| | - Francesco Secchi
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Mangiagalli 31, 20133 Milano, Italy
- Unit of Radiology, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese, Italy
| | - Daniela Mazzaccaro
- Operative Unit of Vascular & Endovascular Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese, Italy
| | - Daniel Giese
- Magnetic Resonance, Siemens Healthcare GmbH, 91050 Erlangen, Germany
| | - Marina Galligani
- Operative Unit of Vascular & Endovascular Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese, Italy
| | - Dor Avishay
- Operative Unit of Vascular & Endovascular Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese, Italy
| | - Davide Capra
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milano, Italy
| | - Caterina Beatrice Monti
- Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milano, Italy
| | - Giovanni Nano
- Operative Unit of Vascular & Endovascular Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097 San Donato Milanese, Italy
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Mangiagalli 31, 20133 Milano, Italy
| |
Collapse
|
5
|
Huellebrand M, Jarmatz L, Manini C, Laube A, Ivantsits M, Schulz-Menger J, Nordmeyer S, Harloff A, Hansmann J, Kelle S, Hennemuth A. Radiomics-based aortic flow profile characterization with 4D phase-contrast MRI. Front Cardiovasc Med 2023; 10:1102502. [PMID: 37077748 PMCID: PMC10106758 DOI: 10.3389/fcvm.2023.1102502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 03/06/2023] [Indexed: 04/05/2023] Open
Abstract
4D PC MRI of the aorta has become a routinely available examination, and a multitude of single parameters have been suggested for the quantitative assessment of relevant flow features for clinical studies and diagnosis. However, clinically applicable assessment of complex flow patterns is still challenging. We present a concept for applying radiomics for the quantitative characterization of flow patterns in the aorta. To this end, we derive cross-sectional scalar parameter maps related to parameters suggested in literature such as throughflow, flow direction, vorticity, and normalized helicity. Derived radiomics features are selected with regard to their inter-scanner and inter-observer reproducibility, as well as their performance in the differentiation of sex-, age- and disease-related flow properties. The reproducible features were tested on user-selected examples with respect to their suitability for characterizing flow profile types. In future work, such signatures could be applied for quantitative flow assessment in clinical studies or disease phenotyping.
Collapse
Affiliation(s)
- Markus Huellebrand
- Deutsches Herzzentrum der Charité, Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
- Fraunhofer Institute for Digital Medicine MEVIS, Berlin, Germany
- Correspondence: Markus Huellebrand
| | - Lina Jarmatz
- Deutsches Herzzentrum der Charité, Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| | - Chiara Manini
- Deutsches Herzzentrum der Charité, Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| | - Ann Laube
- Deutsches Herzzentrum der Charité, Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany
| | - Matthias Ivantsits
- Deutsches Herzzentrum der Charité, Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
| | - Jeanette Schulz-Menger
- Charité Universitätsmedizin Berlin, Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité Universitätsmedizin Berlin and the Max-Delbrück-Center for Molecular Medicine, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany
- Helios Hospital Berlin-Buch, Department of Cardiology and Nephrology, Berlin, Germany
| | - Sarah Nordmeyer
- Deutsches Herzzentrum der Charité, Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany
| | - Andreas Harloff
- Department of Neurology, University Medical Center Freiburg, Freiburg, Germany
- Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Jochen Hansmann
- Department of Radiology, Theresienkrankenhaus und St. Hedwig-Klinik, Mannheim, Germany
| | - Sebastian Kelle
- Deutsches Herzzentrum der Charité, Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany
| | - Anja Hennemuth
- Deutsches Herzzentrum der Charité, Berlin, Germany
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany
- Fraunhofer Institute for Digital Medicine MEVIS, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
6
|
Wiesemann S, Trauzeddel RF, Musa A, Hickstein R, Mayr T, von Knobelsdorff-Brenkenhoff F, Bollache E, Markl M, Schulz-Menger J. Changes of aortic hemodynamics after aortic valve replacement-A four dimensional flow cardiovascular magnetic resonance follow up study. Front Cardiovasc Med 2023; 10:1071643. [PMID: 36865891 PMCID: PMC9971963 DOI: 10.3389/fcvm.2023.1071643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Accepted: 01/19/2023] [Indexed: 02/16/2023] Open
Abstract
Objectives Non-invasive assessment of aortic hemodynamics using four dimensional (4D) flow magnetic resonance imaging (MRI) provides new information on blood flow patterns and wall shear stress (WSS). Aortic valve stenosis (AS) and/or bicuspid aortic valves (BAV) are associated with altered aortic flow patterns and elevated WSS. Aim of this study was to investigate changes in aortic hemodynamics over time in patients with AS and/or BAV with or without aortic valve replacement. Methods We rescheduled 20 patients for a second 4D flow MRI examination, whose first examination was at least 3 years prior. A total of 7 patients received an aortic valve replacement between baseline and follow up examination (=operated group = OP group). Aortic flow patterns (helicity/vorticity) were assessed using a semi-quantitative grading approach from 0 to 3, flow volumes were evaluated in 9 planes, WSS in 18 and peak velocity in 3 areas. Results While most patients had vortical and/or helical flow formations within the aorta, there was no significant change over time. Ascending aortic forward flow volumes were significantly lower in the OP group than in the NOP group at baseline (NOP 69.3 mL ± 14.2 mL vs. OP 55.3 mL ± 1.9 mL p = 0.029). WSS in the outer ascending aorta was significantly higher in the OP group than in the NOP group at baseline (NOP 0.6 ± 0.2 N/m2 vs. OP 0.8 ± 0.2 N/m2, p = 0.008). Peak velocity decreased from baseline to follow up in the aortic arch only in the OP group (1.6 ± 0.6 m/s vs. 1.2 ± 0.3 m/s, p = 0.018). Conclusion Aortic valve replacement influences aortic hemodynamics. The parameters improve after surgery.
Collapse
Affiliation(s)
- Stephanie Wiesemann
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, ECRC Experimental and Clinical Research Center, Working Group Cardiovascular Magnetic Resonance, Berlin, Germany,Department of Cardiology and Nephrology, HELIOS Klinikum Berlin Buch, Berlin, Germany,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Ralf Felix Trauzeddel
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, ECRC Experimental and Clinical Research Center, Working Group Cardiovascular Magnetic Resonance, Berlin, Germany,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany,Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Anesthesiology and Intensive Care Medicine, Charité Campus Benjamin Franklin, Berlin, Germany
| | - Ahmed Musa
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, ECRC Experimental and Clinical Research Center, Working Group Cardiovascular Magnetic Resonance, Berlin, Germany
| | - Richard Hickstein
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, ECRC Experimental and Clinical Research Center, Working Group Cardiovascular Magnetic Resonance, Berlin, Germany
| | - Thomas Mayr
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, ECRC Experimental and Clinical Research Center, Working Group Cardiovascular Magnetic Resonance, Berlin, Germany
| | - Florian von Knobelsdorff-Brenkenhoff
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, ECRC Experimental and Clinical Research Center, Working Group Cardiovascular Magnetic Resonance, Berlin, Germany,Clinic Agatharied, Department of Cardiology, Ludwig Maximilian University of Munich, Hausham, Germany
| | - Emilie Bollache
- CNRS, INSERM, Laboratoire d’Imagerie Biomédicale (LIB), Sorbonne Université, Paris, France
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, United States
| | - Jeanette Schulz-Menger
- Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, ECRC Experimental and Clinical Research Center, Working Group Cardiovascular Magnetic Resonance, Berlin, Germany,Department of Cardiology and Nephrology, HELIOS Klinikum Berlin Buch, Berlin, Germany,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany,*Correspondence: Jeanette Schulz-Menger, ✉
| |
Collapse
|
7
|
Aigner P, Sella Bart E, Panfili S, Körner T, Mach M, Andreas M, Königshofer M, Saitta S, Redaelli A, Schmid A, Moscato F. Quantification of paravalvular leaks associated with TAVI implants using 4D MRI in an aortic root phantom made possible by the use of 3D printing. Front Cardiovasc Med 2023; 10:1083300. [PMID: 36742071 PMCID: PMC9894656 DOI: 10.3389/fcvm.2023.1083300] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 01/02/2023] [Indexed: 01/21/2023] Open
Abstract
Introduction Transcatheter aortic valve implantation (TAVI) has become an alternative to surgical replacement of the aortic valve elderly patients. However, TAVI patients may suffer from paravalvular leaks (PVL). Detecting and grading is usually done by echocardiography, but is limited by resolution, 2D visualization and operator dependency. 4D flow magnetic resonance imaging (MRI) is a promising alternative, which did not reach clinical application in TAVI patients. The aim of this study was applying 3D printing technologies in order to evaluate flow patterns and hemodynamics of PVLs following TAVI, exploiting 4D flow MRI and standard ultrasound. Materials and methods An MR-compatible, anatomically left ventricle, aortic root, and ascending aorta model was fabricated by combining 3D-printed parts and various soft silicone materials to match physiological characteristics. An Abbott Portico™ valve was used in continuous antegrade flow (12-22 l/min), retrograde flow with varying transvalvular pressures (60-110 mmHg), and physiological pulsatile hemodynamics (aortic pressure: 120/80 mmHg, cardiac output: 5 l/min) Time-resolved MR measurements were performed above and below the TAVI stent and compared with color Doppler ultrasound measurements in exactly the same setup. Results The continuous antegrade flow measurements from MRI largely agreed with the flowmeter measurements, and a maximum error of only 7% was observed. In the retrograde configuration, visualization of the paravalvular leaks was possible from the MR measurements, but flow was overestimated by up to 33%. The 4D MRI measurement in the pulsatile setup revealed a single main PVL, which was also confirmed by the color Doppler measurements, and velocities were similar (2.0 m/s vs. 1.7 m/s). Discussion 4D MRI techniques were used to qualitatively assess flow in a patient-specific, MR-compatible and flexible model, which only became possible through the use of 3D printing techniques. Flow patterns in the ascending aorta, identification and quantification of PVLs was possible and the location and extent of PVLs were confirmed by ultrasound measurements. The 4D MRI flow technique allowed evaluation of flow patterns in the ascending aorta and the left ventricle below the TAVI stent with good results in identifying PVLs, demonstrating its capabilities over ultrasound by providing the ability to visualize the paravalvular jets in three dimensions at however, additional expenditure of time and money.
Collapse
Affiliation(s)
- Philipp Aigner
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria,*Correspondence: Philipp Aigner,
| | - Eleonora Sella Bart
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria,Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Sebastiano Panfili
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria,Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Tito Körner
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Markus Mach
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Markus Königshofer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Simone Saitta
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Alberto Redaelli
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Albrecht Schmid
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria,Austrian Cluster for Tissue Regeneration, Vienna, Austria
| |
Collapse
|
8
|
Fujita B, Ensminger S. In-vitro Evaluierung der Neokuspidalisierung nach Ozaki. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2023. [DOI: 10.1007/s00398-022-00553-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
9
|
Khodaei S, Garber L, Bauer J, Emadi A, Keshavarz-Motamed Z. Long-term prognostic impact of paravalvular leakage on coronary artery disease requires patient-specific quantification of hemodynamics. Sci Rep 2022; 12:21357. [PMID: 36494362 PMCID: PMC9734172 DOI: 10.1038/s41598-022-21104-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 09/22/2022] [Indexed: 12/13/2022] Open
Abstract
Transcatheter aortic valve replacement (TAVR) is a frequently used minimally invasive intervention for patient with aortic stenosis across a broad risk spectrum. While coronary artery disease (CAD) is present in approximately half of TAVR candidates, correlation of post-TAVR complications such as paravalvular leakage (PVL) or misalignment with CAD are not fully understood. For this purpose, we developed a multiscale computational framework based on a patient-specific lumped-parameter algorithm and a 3-D strongly-coupled fluid-structure interaction model to quantify metrics of global circulatory function, metrics of global cardiac function and local cardiac fluid dynamics in 6 patients. Based on our findings, PVL limits the benefits of TAVR and restricts coronary perfusion due to the lack of sufficient coronary blood flow during diastole phase (e.g., maximum coronary flow rate reduced by 21.73%, 21.43% and 21.43% in the left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA) respectively (N = 6)). Moreover, PVL may increase the LV load (e.g., LV load increased by 17.57% (N = 6)) and decrease the coronary wall shear stress (e.g., maximum wall shear stress reduced by 20.62%, 21.92%, 22.28% and 25.66% in the left main coronary artery (LMCA), left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA) respectively (N = 6)), which could promote atherosclerosis development through loss of the physiological flow-oriented alignment of endothelial cells. This study demonstrated that a rigorously developed personalized image-based computational framework can provide vital insights into underlying mechanics of TAVR and CAD interactions and assist in treatment planning and patient risk stratification in patients.
Collapse
Affiliation(s)
- Seyedvahid Khodaei
- Department of Mechanical Engineering (Mail to JHE-310), McMaster University, Hamilton, ON, L8S 4L7, Canada
| | - Louis Garber
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada
| | - Julia Bauer
- Department of Mechanical Engineering (Mail to JHE-310), McMaster University, Hamilton, ON, L8S 4L7, Canada
| | - Ali Emadi
- Department of Mechanical Engineering (Mail to JHE-310), McMaster University, Hamilton, ON, L8S 4L7, Canada
- Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON, Canada
| | - Zahra Keshavarz-Motamed
- Department of Mechanical Engineering (Mail to JHE-310), McMaster University, Hamilton, ON, L8S 4L7, Canada.
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
- School of Computational Science and Engineering, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
10
|
Salgado R, El Addouli H, Budde RPJ. Transcatheter Aortic Valve Implantation: The Evolving Role of the Radiologist in 2021. ROFO-FORTSCHR RONTG 2021; 193:1411-1425. [PMID: 34814198 DOI: 10.1055/a-1645-1873] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND Transcatheter aortic valve implantation (TAVI) has gained worldwide acceptance and implementation as an alternative therapeutic option in patients with severe aortic valve stenosis unable to safely undergo surgical aortic valve replacement. This transformative technique places the radiologist in a key position in the pre-procedural assessment of potential candidates for this technique, delivering key anatomical information necessary for patient eligibility and procedural safety. Recent trials also provide encouraging results to potentially extend the indication to patients with safer risk profiles. METHOD The review is based on a PubMed literature search using the search terms "transcatheter heart valve", "TAVI", "TAVR", "CT", "imaging", "MR" over a period from 2010-2020, combined with personal comments based on the author's experience. RESULTS AND CONCLUSION CT plays a prominent role in the pre-procedural workup, delivering as a true 3D imaging modality optimal visualization of the complex anatomy of the aortic root with simultaneous evaluation of the patency of the different access routes. As such, the contribution of CT is key for the determination of patient eligibility and procedural safety. This input is supplementary to the contributions of other imaging modalities and forms an important element in the discussions of the Heart Valve Team. Knowledge of the procedure and its characteristics is necessary in order to provide a comprehensive and complete report. While the role of CT in the pre-procedural evaluation is well established, the contribution of CT and MR and the clinical significance of their findings in the routine follow-up after the intervention are less clear and currently the subject of intense investigation. Important issues remain, including the occurrence and significance of subclinical leaflet thrombosis, prosthetic heart valve endocarditis, and long-term structural valve degeneration. KEY POINTS · CT plays a crucial role in evaluating transcatheter heart valve candidates. · Evaluation must include the dimensions of the aortic root and access paths. · The exact post-procedural role of CT and MRI has not yet been determined.. CITATION FORMAT · Salgado R, El Addouli H, Budde RP. Transcatheter Aortic Valve Implantation: The Evolving Role of the Radiologist in 2021. Fortschr Röntgenstr 2021; 193: 1411 - 1425.
Collapse
Affiliation(s)
- Rodrigo Salgado
- Radiology, UZA, Edegem, Belgium.,Radiology, Holy Heart Hospital Lier, Belgium
| | | | | |
Collapse
|
11
|
Petersen J, Lenz A, Adam G, Reichenspurner H, Bannas P, Girdauskas E. Changes in transvalvular flow patterns after aortic valve repair: comparison of symmetric versus asymmetric aortic valve geometry. Eur J Cardiothorac Surg 2021; 59:1087-1094. [PMID: 33284970 DOI: 10.1093/ejcts/ezaa445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 10/28/2020] [Accepted: 11/10/2020] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES The aim of this study was to compare the effect of asymmetric versus symmetric bicuspid aortic valve (BAV) repair on transvalvular flow patterns and aortic wall shear stress (WSS). METHODS Four-dimensional flow magnetic resonance imaging was prospectively and consecutively performed in patients with congenital aortic valve (AV) disease before and after AV repair. The following MRI-based parameters were assessed: (i) flow eccentricity index, (ii) backward flow across the AV, (iii) grading of vortical and helical flow, and (iv) WSS (N/m2) in the proximal aorta. MRI-derived flow parameters were compared between patients who underwent 'asymmetric BAV repair' (n = 13) and 'symmetric BAV repair' (n = 7). RESULTS A total of 20 patients (39 ± 12 years, 80% male), who underwent BAV repair, were included. In the asymmetric BAV repair group, circumferential WSS reduction was found at the level of the aortic arch (P = 0.015). In the symmetric BAV repair group, postoperative circumferential WSS was significantly reduced compared to baseline at all levels of the proximal aorta (all P < 0.05). Postoperative circumferential WSS was significantly higher in the asymmetric versus symmetric BAV repair group at the level of the sinotubular junction (0.45 ± 0.15 vs 0.30 ± 0.09 N/m2; P = 0.028), ascending aorta (0.59 ± 0.19 vs 0.44 ± 0.08 N/m2; P = 0.021) and aortic arch (0.59 ± 0.25 vs 0.40 ± 0.08 N/m2; P = 0.017). Segmental WSS analysis showed significantly higher postoperative WSS after asymmetric versus symmetric BAV repair, especially in the anterior aortic segment (P = 0.004). CONCLUSIONS Symmetric BAV repair results in more physiological flow patterns and significantly reduces WSS, as compared to asymmetric BAV repair. From a haemodynamic point of view, symmetric AV geometry should be attempted in every congenital AV repair.
Collapse
Affiliation(s)
- Johannes Petersen
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, UKE, Hamburg, Germany
| | - Alexander Lenz
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Gerhard Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Hermann Reichenspurner
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, UKE, Hamburg, Germany
| | - Peter Bannas
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Evaldas Girdauskas
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, UKE, Hamburg, Germany
| |
Collapse
|
12
|
Komoriyama H, Kamiya K, Nagai T, Oyama-Manabe N, Tsuneta S, Kobayashi Y, Kato Y, Sarashina M, Omote K, Konishi T, Sato T, Tsujinaga S, Iwano H, Shingu Y, Wakasa S, Anzai T. Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement. J Cardiovasc Magn Reson 2021; 23:81. [PMID: 34176516 PMCID: PMC8237445 DOI: 10.1186/s12968-021-00771-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 05/04/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. METHODS We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. RESULTS After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034). CONCLUSIONS In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
Collapse
Affiliation(s)
- Hirokazu Komoriyama
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kiwamu Kamiya
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Toshiyuki Nagai
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan.
| | - Noriko Oyama-Manabe
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Yuta Kobayashi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yoshiya Kato
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Miwa Sarashina
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kazunori Omote
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Takao Konishi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Takuma Sato
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Shingo Tsujinaga
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Hiroyuki Iwano
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yasushige Shingu
- Department of Cardiovascular and Thoracic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Satoru Wakasa
- Department of Cardiovascular and Thoracic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Toshihisa Anzai
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| |
Collapse
|
13
|
Demir A, Wiesemann S, Erley J, Schmitter S, Trauzeddel RF, Pieske B, Hansmann J, Kelle S, Schulz-Menger J. Traveling Volunteers: A Multi-Vendor, Multi-Center Study on Reproducibility and Comparability of 4D Flow Derived Aortic Hemodynamics in Cardiovascular Magnetic Resonance. J Magn Reson Imaging 2021; 55:211-222. [PMID: 34173297 DOI: 10.1002/jmri.27804] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 06/14/2021] [Accepted: 06/15/2021] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND Implementation of four-dimensional flow magnetic resonance (4D Flow MR) in clinical routine requires awareness of confounders. PURPOSE To investigate inter-vendor comparability of 4D Flow MR derived aortic hemodynamic parameters, assess scan-rescan repeatability, and intra- and interobserver reproducibility. STUDY TYPE Prospective multicenter study. POPULATION Fifteen healthy volunteers (age 24.5 ± 5.3 years, 8 females). FIELD STRENGTH/SEQUENCE 3 T, vendor-provided and clinically used 4D Flow MR sequences of each site. ASSESSMENT Forward flow volume, peak velocity, average, and maximum wall shear stress (WSS) were assessed via nine planes (P1-P9) throughout the thoracic aorta by a single observer (AD, 2 years of experience). Inter-vendor comparability as well as scan-rescan, intra- and interobserver reproducibility were examined. STATISTICAL TESTS Equivalence was tested setting the 95% confidence interval of intraobserver and scan-rescan difference as the limit of clinical acceptable disagreement. Intraclass correlation coefficient (ICC) and Bland-Altman plots were used for scan-rescan reproducibility and intra- and interobserver agreement. A P-value <0.05 was considered statistically significant. ICCs ≥ 0.75 indicated strong correlation (>0.9: excellent, 0.75-0.9: good). RESULTS Ten volunteers finished the complete study successfully. 4D flow derived hemodynamic parameters between scanners of three different vendors are not equivalent exceeding the equivalence range. P3-P9 differed significantly between all three scanners for forward flow (59.1 ± 13.1 mL vs. 68.1 ± 12.0 mL vs. 55.4 ± 13.1 mL), maximum WSS (1842.0 ± 190.5 mPa vs. 1969.5 ± 398.7 mPa vs. 1500.6 ± 247.2 mPa), average WSS (1400.0 ± 149.3 mPa vs. 1322.6 ± 211.8 mPa vs. 1142.0 ± 198.5 mPa), and peak velocity between scanners I vs. III (114.7 ± 12.6 cm/s vs. 101.3 ± 15.6 cm/s). Overall, the plane location at the sinotubular junction (P1) presented most inter-vendor stability (forward: 78.5 ± 15.1 mL vs. 80.3 ± 15.4 mL vs. 79.5 ± 19.9 mL [P = 0.368]; peak: 126.4 ± 16.7 cm/s vs. 119.7 ± 13.6 cm/s vs. 111.2 ± 22.6 cm/s [P = 0.097]). Scan-rescan reproducibility and intra- and interobserver variability were good to excellent (ICC ≥ 0.8) with best agreement for forward flow (ICC ≥ 0.98). DATA CONCLUSION The clinical protocol used at three different sites led to differences in hemodynamic parameters assessed by 4D flow. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- Aylin Demir
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité-Universitätsmedizin Berlin, Department of Internal Medicine and Cardiology, and the Max-Delbrueck Center for Molecular Medicine, and HELIOS Klinikum Berlin Buch, Department of Cardiology and Nephrology, Berlin, Germany
| | - Stephanie Wiesemann
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité-Universitätsmedizin Berlin, Department of Internal Medicine and Cardiology, and the Max-Delbrueck Center for Molecular Medicine, and HELIOS Klinikum Berlin Buch, Department of Cardiology and Nephrology, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Jennifer Erley
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Berlin, Germany
| | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Ralf Felix Trauzeddel
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité-Universitätsmedizin Berlin, Department of Internal Medicine and Cardiology, and the Max-Delbrueck Center for Molecular Medicine, and HELIOS Klinikum Berlin Buch, Department of Cardiology and Nephrology, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.,Department of Anesthesiology and Intensive Care Medicine, Charité Campus Benjamin Franklin, Berlin, Germany
| | - Burkert Pieske
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.,Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Berlin, Germany.,Department of Internal Medicine/Cardiology, Charité Campus Virchow Klinikum, Berlin, Germany
| | - Jochen Hansmann
- Department of Radiology, Theresienkrankenhaus und St. Hedwig-Klinik, Mannheim, Germany
| | - Sebastian Kelle
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.,Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Berlin, Germany.,Department of Internal Medicine/Cardiology, Charité Campus Virchow Klinikum, Berlin, Germany
| | - Jeanette Schulz-Menger
- Working Group on Cardiovascular Magnetic Resonance, Experimental and Clinical Research Center, a joint cooperation between the Charité-Universitätsmedizin Berlin, Department of Internal Medicine and Cardiology, and the Max-Delbrueck Center for Molecular Medicine, and HELIOS Klinikum Berlin Buch, Department of Cardiology and Nephrology, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| |
Collapse
|
14
|
Nordmeyer S, Hellmeier F, Yevtushenko P, Kelm M, Lee CB, Lehmann D, Kropf S, Berger F, Falk V, Knosalla C, Kuehne T, Goubergrits L. Abnormal aortic flow profiles persist after aortic valve replacement in the majority of patients with aortic valve disease: how model-based personalized therapy planning could improve results. A pilot study approach. Eur J Cardiothorac Surg 2021; 57:133-141. [PMID: 31131388 DOI: 10.1093/ejcts/ezz149] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Revised: 04/17/2019] [Accepted: 04/18/2019] [Indexed: 01/16/2023] Open
Abstract
OBJECTIVES Complex blood flow profiles in the aorta are known to contribute to vessel dilatation. We studied flow profiles in the aorta in patients with aortic valve disease before and after surgical aortic valve replacement (AVR). METHODS Thirty-four patients with aortic valve disease underwent 4-dimensional velocity-encoded magnetic resonance imaging before and after AVR (biological valve = 27, mechanical valve = 7). Seven healthy volunteers served as controls. Eccentricity (ES) and complex flow scores (CFS) were determined from the degree of helicity, vorticity and eccentricity of flow profiles in the aorta. Model-based therapy planning was used in 4 cases to improve in silico postoperative flow profiles by personalized adjustment of size, rotation and angulation of the valve as well as aorta diameter. RESULTS Patients with aortic valve disease showed more complex flow than controls [median ES 2.5 (interquartile range (IQR) 2.3-2.7) vs 1.0 (IQR 1.0-1.0), P < 0.001, median CFS 4.7 (IQR 4.3-4.8) vs 1.0 (IQR 1.0-2.0), P < 0.001]. After surgery, flow complexity in the total patient cohort was reduced, but remained significantly higher compared to controls [median ES 2.3 (IQR 1.9-2.3) vs 1.0 (IQR 1.0-1.0), P < 0.001, median CFS 3.8 (IQR 3.0-4.3) vs 1.0 (IQR 1.0-2.0), P < 0.001]. In patients after mechanical AVR, flow complexity fell substantially and showed no difference from controls [median ES 1.0 (IQR 1.0-2.3) vs 1.0 (IQR 1.0-1.0), P = 0.46, median CFS 1.0 (IQR 1.0-3.3) vs 1.0 (IQR 1.0-2.0), P = 0.71]. In all 4 selected cases (biological, n = 2; mechanical, n = 2), model-based therapy planning reduced in silico complexity of flow profiles compared to the existing post-surgical findings [median ES 1.7 (IQR 1.4-1.7) vs 2.3 (IQR 2.3-2.3); CFS 1.7 (IQR 1.4-2.5) vs 3.8 (IQR 3.3-4.3)]. CONCLUSIONS Abnormal flow profiles in the aorta more frequently persist after surgical AVR. Model-based therapy planning might have the potential to optimize treatment for best possible individual outcome. CLINICAL TRIAL REGISTRATION NUMBER clinicaltrials.gov NCT03172338, 1 June 2017, retrospectively registered; NCT02591940, 30 October 2015, retrospectively registered.
Collapse
Affiliation(s)
- Sarah Nordmeyer
- Department of Congenital Heart Disease and Paediatric Cardiology, German Heart Center Berlin, Berlin, Germany.,Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Florian Hellmeier
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Pavel Yevtushenko
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Marcus Kelm
- Department of Congenital Heart Disease and Paediatric Cardiology, German Heart Center Berlin, Berlin, Germany.,Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Chong-Bin Lee
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Daniel Lehmann
- Institute for Gender in Medicine, Center for Cardiovascular Research, Berlin, Germany
| | - Siegfried Kropf
- Institute for Biometrics and Medical Informatics, Otto-von-Guericke Universität Magdeburg, Magdeburg, Germany
| | - Felix Berger
- Department of Congenital Heart Disease and Paediatric Cardiology, German Heart Center Berlin, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Volkmar Falk
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.,Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
| | - Christoph Knosalla
- DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.,Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
| | - Titus Kuehne
- Department of Congenital Heart Disease and Paediatric Cardiology, German Heart Center Berlin, Berlin, Germany.,Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Berlin, Germany
| | - Leonid Goubergrits
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
15
|
Cave DGW, Panayiotou H, Bissell MM. Hemodynamic Profiles Before and After Surgery in Bicuspid Aortic Valve Disease-A Systematic Review of the Literature. Front Cardiovasc Med 2021; 8:629227. [PMID: 33842561 PMCID: PMC8024488 DOI: 10.3389/fcvm.2021.629227] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 03/02/2021] [Indexed: 11/25/2022] Open
Abstract
Bicuspid aortic valve (BAV) disease presents a unique management challenge both pre- and post-operatively. 4D flow MRI offers multiple tools for the assessment of the thoracic aorta in aortic valve disease. In particular, its assessment of flow patterns and wall shear stress have led to new understandings around the mechanisms of aneurysm development in BAV disease. Novel parameters have now been developed that have the potential to predict pathological aortic dilatation and may help to risk stratify BAV patients in future. This systematic review analyses the current 4D flow MRI literature after aortic valve and/or ascending aortic replacement in bicuspid aortic valve disease. 4D flow MRI has also identified distinct challenges posed by this cohort at the time of valve replacement compared to standard management of tri-leaflet disorders, and may help tailor the type and timing of replacement. Eccentric pathological flow patterns seen after bioprosthetic valve implantation, but not with mechanical prostheses, might be an important future consideration in intervention planning. 4D flow MRI also has promising potential in supporting the development of artificial valve prostheses and aortic conduits with more physiological flow patterns.
Collapse
Affiliation(s)
- Daniel G W Cave
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, United Kingdom
| | - Hannah Panayiotou
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, United Kingdom
| | - Malenka M Bissell
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
16
|
Kanda H, Yamakuchi M, Matsumoto K, Mukaihara K, Shigehisa Y, Tachioka S, Okawa M, Takenouchi K, Oyama Y, Hashiguchi T, Imoto Y. Dynamic changes in platelets caused by shear stress in aortic valve stenosis. Clin Hemorheol Microcirc 2021; 77:71-81. [PMID: 32924997 PMCID: PMC7990459 DOI: 10.3233/ch-200928] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
BACKGROUND AND OBJECTIVE: Turbulent blood flow in patients with aortic valve stenosis (AS) results in morphological and functional changes in platelets and coagulation factors. The aim of this study is to determine how shear stress affects platelets and coagulation factors. METHODS: We retrospectively evaluated data from 78 patients who underwent AVR to treat AS between March 2008 and July 2017 at Kagoshima University Hospital. RESULTS: Platelet (PLT) count obviously decreased at three days after AVR, and increased above preoperative levels at the time of discharge. In contrast, platelet distribution width (PDW), mean platelet volume (MPV), and platelet large cell ratio (P-LCR) increased three days after AVR, then decreased to below preoperative levels. No differences were evident between groups with higher (HPPG > 100 mmHg) and lower (LPPG < 100 mmHg) peak pressure gradients (PPG) before AVR, whereas PLT count, PDW, MPV and P-LCR improved more in the HPPG group. Plateletcrit (PCT), which represents the total volume of platelets, increased after AVR due to decreased shear stress. High increasing rate of PCT was associated with lower PLT count, higher PDW and lower fibrinogen. CONCLUSION: Shear stress affects PLT count, PDW, and fibrinogen in patients with AS.
Collapse
Affiliation(s)
- Hideaki Kanda
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Munekazu Yamakuchi
- Department of Laboratory and Vascular Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Kazuhisa Matsumoto
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Kosuke Mukaihara
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Yoshiya Shigehisa
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Shuji Tachioka
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Masashi Okawa
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Kazunori Takenouchi
- Department of Laboratory and Vascular Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Yoko Oyama
- Department of Laboratory and Vascular Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Teruto Hashiguchi
- Department of Laboratory and Vascular Medicine, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Yutaka Imoto
- Cardiovascular and Gastroenterological Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| |
Collapse
|
17
|
Transcatheter Heart Valve Downstream Fluid Dynamics in an Accelerated Evaluation Environment. Ann Biomed Eng 2021; 49:2170-2182. [PMID: 33638029 DOI: 10.1007/s10439-021-02751-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 02/12/2021] [Indexed: 10/22/2022]
Abstract
Transcatheter aortic valve replacements (TAVRs) provide minimally invasive delivery of bioprosthetic heart valves (BHVs) for the treatment of aortic valve disease. While surgical BHVs show efficacy for 8-10 years, long-term TAVR durability remains unknown. Pre-clinical testing evaluates BHV durability in an ISO:5840 compliant accelerated wear tester (AWT), yet, the design and development of AWTs and their accuracy in predicting in vivo performance, is unclear. As a result of limited knowledge on AWT environment and BHV loading, durability assessment of candidate valves remains fundamentally empirical. For the first time, high-speed particle image velocimetry quantified an ISO:5840 compliant downstream AWT velocity field, Reynolds stresses, and turbulence intensity. TAVR enface imaging quantified the orifice area and estimated the flow rate. When valve area and flow rate were at their maximum during peak systole (1.49 cm2 and 16.05 L/min, respectively), central jet velocity, Reynolds normal and shear stress, and turbulence intensity grew to 0.50 m/s, 265.1 Pa, 124.6 Pa, and 37.3%, respectively. During diastole, unique AWT recirculation produced retrograde flow and the directional changes created eddies. These novel AWT findings demonstrated a substantially reduced valve fully loaded period and pressure not matching in vivo or in vitro studies, despite the comparable fluid environment and TAVR motion.
Collapse
|
18
|
Wiesemann S, Schmitter S, Demir A, Prothmann M, Schwenke C, Chawla A, von Knobelsdorff-Brenkenhoff F, Greiser A, Jin N, Bollache E, Markl M, Schulz-Menger J. Impact of sequence type and field strength (1.5, 3, and 7T) on 4D flow MRI hemodynamic aortic parameters in healthy volunteers. Magn Reson Med 2020; 85:721-733. [PMID: 32754969 DOI: 10.1002/mrm.28450] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 06/22/2020] [Accepted: 07/08/2020] [Indexed: 01/15/2023]
Abstract
PURPOSE 4D flow magnetic resonance imaging (4D-MRI) allows time-resolved visualization of blood flow patterns, quantification of volumes, velocities, and advanced parameters, such as wall shear stress (WSS). As 4D-MRI enters the clinical arena, standardization and awareness of confounders are important. Our aim was to evaluate the equivalence of 4D flow-derived aortic hemodynamics in healthy volunteers using different sequences and field strengths. METHODS 4D-MRI was acquired in 10 healthy volunteers at 1.5T using three different prototype sequences, at 3T and at 7T (Siemens Healthineers). After evaluation of diagnostic quality in three segments (ascending-, descending aorta, aortic arch), peak velocity, flow volumes, and WSS were investigated. Equivalence limits for comparison of field strengths/sequences were based on the limits of Bland-Altman analyses of the intraobserver variability. RESULTS Non-diagnostic quality was found in 10/144 segments, 9/10 were obtained at 7T. Apart for the comparison of forward flow between sequence 1 and 3, the differences in measurements between field strengths/sequences exceeded the range of agreement. Significant differences were found between field strengths/sequences for forward flow (1.5T vs. 3T, 3T vs. 7T, sequence 1 vs. 3, 2 vs. 3 [P < .001]), WSS (1.5T vs. 3T [P < .05], sequence 1 vs. 2, 1 vs. 3, 2 vs. 3 [P < .001]), and peak velocity (1.5T vs. 7T, sequence 1 vs. 3 [P > .001]). All parameters at all field strengths/with all sequences correlated moderately to strongly (r ≥ 0.5). CONCLUSION Data from all sequences could be acquired and resulting images showed sufficient quality for further analysis. However, the variability of the measurements of peak velocity, flow volumes, and WSS was higher when comparing field strengths/sequences as the equivalence limits defined by the intraobserver assessments.
Collapse
Affiliation(s)
- Stephanie Wiesemann
- Department of Cardiology and Nephrology, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin Buch, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), partner site Berlin, Berlin, Germany
| | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Aylin Demir
- Department of Cardiology and Nephrology, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin Buch, Berlin, Germany
| | - Marcel Prothmann
- Department of Cardiology and Nephrology, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin Buch, Berlin, Germany
| | | | - Ashish Chawla
- Khoo Teck Puat Hospital, Yishun Central, Singapore, Singapore
| | - Florian von Knobelsdorff-Brenkenhoff
- Department of Cardiology and Nephrology, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin Buch, Berlin, Germany.,Clinic Agatharied, Department of Cardiology, Ludwig-Maximilians-University Munich, Hausham, Germany
| | | | - Ning Jin
- Siemens Medical Solutions, Columbus, Ohio, USA
| | - Emilie Bollache
- Sorbonne Université, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale, LIB, Paris, France
| | - Michael Markl
- Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA
| | - Jeanette Schulz-Menger
- Department of Cardiology and Nephrology, Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine and HELIOS Hospital Berlin Buch, Berlin, Germany.,DZHK (German Center for Cardiovascular Research), partner site Berlin, Berlin, Germany
| |
Collapse
|
19
|
Celis D, Gomes BADA, Ibanez I, Azevedo PN, Teixeira PS, Nieckele AO. Prediction of Stress Map in Ascending Aorta - Optimization of the Coaxial Position in Transcatheter Aortic Valve Replacement. Arq Bras Cardiol 2020; 115:680-687. [PMID: 32491131 PMCID: PMC8386968 DOI: 10.36660/abc.20190385] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Accepted: 11/25/2019] [Indexed: 11/18/2022] Open
Abstract
BACKGROUD Transcatheter aortic valve replacement (TAVR) can reduce mortality among patients with aortic stenosis. Knowledge of pressure distribution and shear stress at the aortic wall may help identify critical regions, where aortic remodeling process may occur. Here a numerical simulation study of the influence of positioning of the prosthetic valve orifice on the flow field is presented. OBJECTIVE The present analysis provides a perspective of great variance on flow behavior due only to angle changes. METHODS A 3D model was generated from computed tomography angiography of a patient who had undergone a TAVR. Different mass flow rates were imposed at the inlet valve. RESULTS Small variations of the tilt angle could modify the nature of the flow, displacing the position of the vortices, and altering the prerssure distribution and the location of high wall shear stress. CONCLUSION These hemodynamic features may be relevant in the aortic remodeling process and distribution of the stress mapping and could help, in the near future, the optimization of the percutaneous prosthesis implantation. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).
Collapse
Affiliation(s)
- Diego Celis
- Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) - Departamento de Engenharia Mecânica, Rio de Janeiro, RJ - Brasil
| | - Bruno Alvares de Azevedo Gomes
- Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) - Departamento de Engenharia Mecânica, Rio de Janeiro, RJ - Brasil.,Instituto Nacional de Cardiologia, Ministério da Saúde, Rio de Janeiro, RJ - Brasil
| | - Ivan Ibanez
- Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) - Departamento de Engenharia Mecânica, Rio de Janeiro, RJ - Brasil
| | - Pedro Nieckele Azevedo
- Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) - Departamento de Engenharia Mecânica, Rio de Janeiro, RJ - Brasil
| | | | - Angela Ourivio Nieckele
- Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) - Departamento de Engenharia Mecânica, Rio de Janeiro, RJ - Brasil
| |
Collapse
|
20
|
Jarral OA, Tan MKH, Salmasi MY, Pirola S, Pepper JR, O'Regan DP, Xu XY, Athanasiou T. Phase-contrast magnetic resonance imaging and computational fluid dynamics assessment of thoracic aorta blood flow: a literature review. Eur J Cardiothorac Surg 2020; 57:438-446. [PMID: 31638698 DOI: 10.1093/ejcts/ezz280] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Revised: 09/06/2019] [Accepted: 09/17/2019] [Indexed: 11/14/2022] Open
Abstract
The death rate from thoracic aortic disease is on the rise and represents a growing global health concern as patients are often asymptomatic before acute events, which have devastating effects on health-related quality of life. Biomechanical factors have been found to play a major role in the development of both acquired and congenital aortic diseases. However, much is still unknown and translational benefits of this knowledge are yet to be seen. Phase-contrast cardiovascular magnetic resonance imaging of thoracic aortic blood flow has emerged as an exceptionally powerful non-invasive tool enabling visualization of complex flow patterns, and calculation of variables such as wall shear stress. This has led to multiple new findings in the areas of phenotype-dependent bicuspid valve flow patterns, thoracic aortic aneurysm formation and aortic prosthesis performance assessment. Phase-contrast cardiovascular magnetic resonance imaging has also been used in conjunction with computational fluid modelling techniques to produce even more sophisticated analyses, by allowing the calculation of haemodynamic variables with exceptional temporal and spatial resolution. Translationally, these technologies may potentially play a major role in the emergence of precision medicine and patient-specific treatments in patients with aortic disease. This clinically focused review will provide a systematic overview of key insights from published studies to date.
Collapse
Affiliation(s)
- Omar A Jarral
- Department of Surgery and Cancer, Imperial College London, London, UK
| | - Matthew K H Tan
- Department of Surgery and Cancer, Imperial College London, London, UK
| | | | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, London, UK
| | - John R Pepper
- National Heart and Lung Institute, Imperial College London, London, UK
| | - Declan P O'Regan
- MRC London Institute of Medical Sciences, Imperial College London, London, UK
| | - Xiao Y Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Thanos Athanasiou
- Department of Surgery and Cancer, Imperial College London, London, UK
| |
Collapse
|
21
|
Oechtering TH, Sieren M, Schubert K, Schaller T, Scharfschwerdt M, Panagiotopoulos A, Fujita B, Auer C, Barkhausen J, Ensminger S, Sievers HH, Frydrychowicz A. In vitro 4D Flow MRI evaluation of aortic valve replacements reveals disturbed flow distal to biological but not to mechanical valves. J Card Surg 2019; 34:1452-1457. [PMID: 31638731 DOI: 10.1111/jocs.14253] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND AIM OF THE STUDY Aortic hemodynamics influence the integrity of the vessel wall and cardiac afterload. The aim of this study was to compare hemodynamics distal to biological (BV) and mechanical aortic valve (MV) replacements by in vitro 4D Flow MRI excluding confounding factors of in-vivo testing potentially influencing hemodynamics. METHODS Two BV (Perimount MagnaEase [Carpentier-Edwards], Trifecta [Abbott]) and two MV (On-X [CryoLife], prototype trileaflet valve) were scanned in a flexible aortic phantom at 3T using a recommended 4D Flow MR sequence. A triphasic aortic flow profile with blood-mimicking fluid was established. Using GTFlow (Gyrotools), area and velocity of the ejection jet were measured. Presence and extent of sinus vortices and secondary flow patterns were graded on a 0 to 3 scale. RESULTS A narrow, accelerated central ejection jet (Area = 27 ± 7% of vessel area, Velocity = 166 ± 13 cm/s; measured at sinotubular junction) was observed in BV as compared to MV (Area = 53 ± 13%, Velocity = 109 ± 21 cm/s). As opposed to MV, the jet distal to BV impacted the outer curvature of the ascending aorta and resulted in large secondary flow patterns (BV: n = 4, grades 3, 3, 2, 1; MV: n = 1, grade 1). Sinus vortices only formed distal to MV. Although physiologically configured, they were larger than normal (grade 3). CONCLUSIONS In contrast to mechanical valves, biological valve replacements induced accelerated and increased flow patterns deviating from physiological ones. While it remains speculative whether this increases the risk of aneurysm formation through wall shear stress changes, findings are contrasted by almost no secondary flow patterns and typical, near-physiological sinus vortex formation distal to mechanical valves.
Collapse
Affiliation(s)
- Thekla H Oechtering
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Malte Sieren
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Kathrin Schubert
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Tim Schaller
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Michael Scharfschwerdt
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Apostolos Panagiotopoulos
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Buntaro Fujita
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Christian Auer
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Jörg Barkhausen
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Stephan Ensminger
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Hans-Hinrich Sievers
- Department of Cardiac and Thoracic Vascular Surgery, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Alex Frydrychowicz
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| |
Collapse
|
22
|
Yevtushenko P, Hellmeier F, Bruening J, Nordmeyer S, Falk V, Knosalla C, Kelm M, Kuehne T, Goubergrits L. Surgical Aortic Valve Replacement: Are We Able to Improve Hemodynamic Outcome? Biophys J 2019; 117:2324-2336. [PMID: 31427066 DOI: 10.1016/j.bpj.2019.07.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 06/18/2019] [Accepted: 07/17/2019] [Indexed: 01/16/2023] Open
Abstract
Aortic valve replacement (AVR) does not usually restore physiological flow profiles. Complex flow profiles are associated with aorta dilatation, ventricle remodeling, aneurysms, and development of atherosclerosis. All these affect long-term morbidity and often require reoperations. In this pilot study, we aim to investigate an ability to optimize the real surgical AVR procedure toward flow profile associated with healthy persons. Four cases of surgical AVR (two with biological and two with mechanical valve prosthesis) with available post-treatment cardiac magnetic resonance imaging (MRI), including four-dimensional flow MRI and showing abnormal complex post-treatment hemodynamics, were investigated. All cases feature complex hemodynamic outcomes associated with valve-jet eccentricity and strong secondary flow characterized by helical flow and recirculation regions. A commercial computational fluid dynamics solver was used to simulate peak systolic hemodynamics of the real post-treatment outcome using patient-specific MRI measured boundary conditions. Then, an attempt to optimize hemodynamic outcome by modifying valve size and orientation as well as ascending aorta size reduction was made. Pressure drop, wall shear stress, secondary flow degree, helicity, maximal velocity, and turbulent kinetic energy were evaluated to characterize the AVR hemodynamic outcome. The proposed optimization strategy was successful in three of four cases investigated. Although no single parameter was identified as the sole predictor for a successful flow optimization, downsizing of the ascending aorta in combination with the valve orientation was the most effective optimization approach. Simulations promise to become an effective tool to predict hemodynamic outcome. The translation of these tools requires, however, studies with a larger cohort of patients followed by a prospective clinical validation study.
Collapse
Affiliation(s)
- Pavlo Yevtushenko
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Germany
| | - Florian Hellmeier
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Germany
| | - Jan Bruening
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Germany
| | - Sarah Nordmeyer
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Germany; Department of Congenital Heart Disease and Paediatric Cardiology, DHZB (German Heart Center Berlin), Berlin, Germany
| | - Volkmar Falk
- Partner Site Berlin, DZHK (German Centre for Cardiovascular Research), Berlin, Germany; Department of Cardiothoracic and Vascular Surgery, DHZB, Berlin, Germany
| | - Christoph Knosalla
- Partner Site Berlin, DZHK (German Centre for Cardiovascular Research), Berlin, Germany; Department of Cardiothoracic and Vascular Surgery, DHZB, Berlin, Germany
| | - Marcus Kelm
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Germany; Department of Congenital Heart Disease and Paediatric Cardiology, DHZB (German Heart Center Berlin), Berlin, Germany
| | - Titus Kuehne
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Germany; Partner Site Berlin, DZHK (German Centre for Cardiovascular Research), Berlin, Germany; Department of Congenital Heart Disease and Paediatric Cardiology, DHZB (German Heart Center Berlin), Berlin, Germany
| | - Leonid Goubergrits
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Germany.
| |
Collapse
|
23
|
Gülan U, Appa H, Corso P, Templin C, Bezuidenhout D, Zilla P, Duru F, Holzner M. Performance analysis of the transcatheter aortic valve implantation on blood flow hemodynamics: An optical imaging‐based in vitro study. Artif Organs 2019; 43:E282-E293. [DOI: 10.1111/aor.13504] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 04/11/2019] [Accepted: 05/23/2019] [Indexed: 11/29/2022]
Affiliation(s)
- Utku Gülan
- Institute for Environmental Engineering Swiss Federal Institute of Technology Zurich Zurich Switzerland
| | - Harish Appa
- Strait Access Technologies University of Cape Town Observatory South Africa
| | - Pascal Corso
- Institute for Environmental Engineering Swiss Federal Institute of Technology Zurich Zurich Switzerland
| | | | - Deon Bezuidenhout
- Strait Access Technologies University of Cape Town Observatory South Africa
- Cardiovascular Research Unit University of Cape Town Observatory South Africa
| | - Peter Zilla
- Strait Access Technologies University of Cape Town Observatory South Africa
- Cardiovascular Research Unit University of Cape Town Observatory South Africa
| | - Firat Duru
- Department of Cardiology University Heart Center Zurich Switzerland
- Center for Integrative Human Physiology University of Zurich Zurich Switzerland
| | - Markus Holzner
- Institute for Environmental Engineering Swiss Federal Institute of Technology Zurich Zurich Switzerland
| |
Collapse
|
24
|
Comprehensive In Vitro Study of the Flow Past Two Transcatheter Aortic Valves: Comparison with a Severe Stenotic Case. Ann Biomed Eng 2019; 47:2241-2257. [DOI: 10.1007/s10439-019-02289-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Accepted: 05/10/2019] [Indexed: 11/25/2022]
|
25
|
Farag ES, Vendrik J, van Ooij P, Poortvliet QL, van Kesteren F, Wollersheim LW, Kaya A, Driessen AHG, Piek JJ, Koch KT, Baan J, Planken RN, Kluin J, Nederveen AJ, de Mol BAJM. Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls. Eur Radiol 2018; 29:1444-1451. [PMID: 30132105 PMCID: PMC6510864 DOI: 10.1007/s00330-018-5672-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Revised: 07/06/2018] [Accepted: 07/16/2018] [Indexed: 11/01/2022]
Abstract
BACKGROUND With the implementation of transcatheter aortic valve replacement (TAVR) in lower-risk patients, evaluation of blood flow characteristics and the effect of TAVR on aortic dilatation becomes of considerable interest. We employed 4D flow MRI in the ascending aorta of patients after TAVR to assess wall shear stress (WSS) and compare blood flow patterns with surgical aortic valve replacement (SAVR) and age- and gender-matched controls. METHODS Fourteen post-TAVR patients and ten age- and gender-matched controls underwent kt-PCA accelerated 4D flow MRI of the thoracic aorta at 3.0 Tesla. Velocity and wall shear stress was compared between the two groups. In addition, aortic flow eccentricity and displacement was assessed and compared between TAVR patients, controls and 14 SAVR patients recruited as part of an earlier study. RESULTS Compared to controls, abnormally elevated WSS was present in 30±10% of the ascending aortic wall in TAVR patients. Increased WSS was present along the posterior mid-ascending aorta and the anterior distal-ascending aorta in all TAVR patients. TAVR results in eccentric and displaced flow in the mid- and distal-ascending aorta, whereas blood flow displacement in SAVR patients occurs only in the distal-ascending aorta. CONCLUSION This study shows that TAVR results in increased blood flow velocity and WSS in the ascending aorta compared to age- and gender-matched elderly controls. This finding warrants longitudinal assessment of aortic dilatation after TAVR in the era of potential TAVR in lower-risk patients. Additionally, TAVR results in altered blood flow eccentricity and displacement in the mid- and distal-ascending aorta, whereas SAVR only results in altered blood flow eccentricity and displacement in the distal-ascending aorta. KEY POINTS • TAVR results in increased blood flow velocity and WSS in the ascending aorta. • Longitudinal assessment of aortic dilatation after TAVR is warranted in the era of potential TAVR in lower-risk patients. • Both TAVR and SAVR result in altered blood flow patterns in the ascending aorta when compared to age-matched controls.
Collapse
Affiliation(s)
- E S Farag
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands.
| | - J Vendrik
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - P van Ooij
- Department of Radiology and Nuclear Medicine, Academic Medical Centre, Amsterdam, The Netherlands
| | - Q L Poortvliet
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - F van Kesteren
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - L W Wollersheim
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - A Kaya
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - A H G Driessen
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - J J Piek
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - K T Koch
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - J Baan
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - R N Planken
- Department of Radiology and Nuclear Medicine, Academic Medical Centre, Amsterdam, The Netherlands
| | - J Kluin
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| | - A J Nederveen
- Department of Radiology and Nuclear Medicine, Academic Medical Centre, Amsterdam, The Netherlands
| | - B A J M de Mol
- Departments of Cardiology and Cardiothoracic Surgery, Heart Centre, Academic Medical Centre, University of Amsterdam, P.O. Box 22660, 1100 DD, Amsterdam, The Netherlands
| |
Collapse
|
26
|
Gomes BADA, Camargo GC, Santos JRLD, Azevedo LFA, Nieckele ÂO, Siqueira-Filho AG, Oliveira GMMD. Influence of the tilt angle of Percutaneous Aortic Prosthesis on Velocity and Shear Stress Fields. Arq Bras Cardiol 2017; 109:231-240. [PMID: 28793046 PMCID: PMC5586230 DOI: 10.5935/abc.20170115] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Background Due to the nature of the percutaneous prosthesis deployment process, a
variation in its final position is expected. Prosthetic valve placement will
define the spatial location of its effective orifice in relation to the
aortic annulus. The blood flow pattern in the ascending aorta is related to
the aortic remodeling process, and depends on the spatial location of the
effective orifice. The hemodynamic effect of small variations in the angle
of inclination of the effective orifice has not been studied in detail. Objective To implement an in vitro simulation to characterize the
hydrodynamic blood flow pattern associated with small variations in the
effective orifice inclination. Methods A three-dimensional aortic phantom was constructed, reproducing the anatomy
of one patient submitted to percutaneous aortic valve implantation. Flow
analysis was performed by use of the Particle Image Velocimetry technique.
The flow pattern in the ascending aorta was characterized for six flow rate
levels. In addition, six angles of inclination of the effective orifice were
assessed. Results The effective orifice at the -4º and -2º angles directed the main flow
towards the anterior wall of the aortic model, inducing asymmetric and high
shear stress in that region. However, the effective orifice at the +3º and
+5º angles mimics the physiological pattern, centralizing the main flow and
promoting a symmetric distribution of shear stress. Conclusion The measurements performed suggest that small changes in the angle of
inclination of the percutaneous prosthesis aid in the generation of a
physiological hemodynamic pattern, and can contribute to reduce aortic
remodeling.
Collapse
Affiliation(s)
- Bruno Alvares de Azevedo Gomes
- Programa de Pós Graduação em Cardiologia - Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ - Brazil.,Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio), Rio de Janeiro, RJ - Brazil.,Instituto Nacional de Cardiologia, INC/MS, Rio de Janeiro, RJ - Brazil
| | - Gabriel Cordeiro Camargo
- Programa de Pós Graduação em Cardiologia - Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ - Brazil
| | | | | | | | | | | |
Collapse
|
27
|
Late subclinical hemolysis and long-term outcomes after aortic valve replacement with On-X mechanical prostheses - a preliminary single-center report. POLISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY 2017; 14:175-179. [PMID: 29181045 PMCID: PMC5701593 DOI: 10.5114/kitp.2017.70531] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Accepted: 09/03/2017] [Indexed: 11/17/2022]
Abstract
Introduction Aortic valve replacement (AVR) with a mechanical prosthesis is not free from late complications. Aim To evaluate the prevalence of subclinical hemolysis after AVR with On-X prostheses and assess its impact on long-term outcomes. Material and methods The prospective study included 84 consecutive patients aged 58.3 ±10.3 years who underwent AVR. They were retrospectively split into group H (n = 12; 14.3%) with prosthesis-related subclinical hemolysis and a control group (C; n = 72; 85.7%). All operations were performed via median sternotomy using cardio-pulmonary bypass. At the end of follow-up, echocardiography was carried out and blood samples for morphology and biochemistry (lactate dehydrogenase (LDH), bilirubin, haptoglobin) were taken. Results The rate of subclinical hemolysis in patients with properly working prostheses was 14.3% and it was the highest (33.3%) for the smallest valves. Although an improvement in functional status was noted in both groups, it was less evident in group H than in group C (p = 0.007). At the end of follow-up, 97.2% in group C and 75.0% in group H were found in NYHA classes I and II. Patients in group H had significantly lower hemoglobin, hematocrit, and haptoglobin and higher LDH activity than group C subjects. In group H, systolic gradients of On-X valves were higher whereas effective orifice area was smaller than in group C. Conclusions Our study proved that prosthesis-induced subclinical hemolysis is seen even after implantation of the latest generation mechanical prostheses, particularly of small diameter, and its degree may impact late outcome.
Collapse
|
28
|
Bollache E, Fedak PWM, van Ooij P, Rahman O, Malaisrie SC, McCarthy PM, Carr JC, Powell A, Collins JD, Markl M, Barker AJ. Perioperative evaluation of regional aortic wall shear stress patterns in patients undergoing aortic valve and/or proximal thoracic aortic replacement. J Thorac Cardiovasc Surg 2017; 155:2277-2286.e2. [PMID: 29248286 DOI: 10.1016/j.jtcvs.2017.11.007] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 10/11/2017] [Accepted: 11/06/2017] [Indexed: 10/18/2022]
Abstract
OBJECTIVES To assess in patients with aortopathy perioperative changes in thoracic aortic wall shear stress (WSS), which is known to affect arterial remodeling, and the effects of specific surgical interventions. METHODS Presurgical and postsurgical aortic 4D flow MRI were performed in 33 patients with aortopathy (54 ± 14 years; 5 women; sinus of Valsalva (d_SOV)/midascending aortic (d_MAA) diameters = 44 ± 5/45 ± 6 mm) scheduled for aortic valve (AVR) and/or root (ARR) replacement. Control patients with aortopathy who did not have surgery were matched for age, sex, body size, and d_MAA (n = 20: 52 ± 14 years; 3 women; d_SOV/d_MAA = 42 ± 4/42 ± 4 mm). Regional aortic 3D systolic peak WSS was calculated. An atlas of WSS normal values was used to quantify the percentage of at-risk tissue area with abnormally high WSS, excluding the area to be resected/graft. RESULTS Peak WSS and at-risk area showed low interobserver variability (≤0.09 [-0.3; 0.5] Pa and 1.1% [-7%; 9%], respectively). In control patients, WSS was stable over time (follow-up-baseline differences ≤0.02 Pa and 0.0%, respectively). Proximal aortic WSS decreased after AVR (n = 5; peak WSS difference ≤-0.41 Pa and at-risk area ≤-10%, P < .05 vs controls). WSS was increased after ARR in regions distal to the graft (peak WSS difference ≥0.16 Pa and at-risk area ≥4%, P < .05 vs AVR). Follow-up duration had no significant effects on these WSS changes, except when comparing ascending aortic peak WSS between ARR and AVR (P = .006). CONCLUSIONS Serial perioperative 4D flow MRI investigations showed distinct patterns of postsurgical changes in aortic WSS, which included both reductions and translocations. Larger longitudinal studies are warranted to validate these findings with clinical outcomes and prediction of risk of future aortic events.
Collapse
Affiliation(s)
- Emilie Bollache
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - Paul W M Fedak
- Department of Cardiac Sciences, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada; Division of Surgery-Cardiac Surgery, Northwestern University, Chicago, Ill
| | - Pim van Ooij
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
| | - Ozair Rahman
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - S Chris Malaisrie
- Division of Surgery-Cardiac Surgery, Northwestern University, Chicago, Ill
| | - Patrick M McCarthy
- Division of Surgery-Cardiac Surgery, Northwestern University, Chicago, Ill
| | - James C Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - Alex Powell
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - Jeremy D Collins
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill; Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, Ill
| | - Alex J Barker
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill.
| |
Collapse
|
29
|
Cardiovascular MRI in Thoracic Aortopathy: A Focused Review of Recent Literature Updates. CURRENT RADIOLOGY REPORTS 2017. [DOI: 10.1007/s40134-017-0246-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
30
|
Giese D, Weiss K, Baeßler B, Madershahian N, Choi YH, Maintz D, Bunck AC. In vitro evaluation of flow patterns and turbulent kinetic energy in trans-catheter aortic valve prostheses. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017; 31:165-172. [DOI: 10.1007/s10334-017-0651-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 09/04/2017] [Accepted: 09/05/2017] [Indexed: 11/24/2022]
|
31
|
Model-Based Therapy Planning Allows Prediction of Haemodynamic Outcome after Aortic Valve Replacement. Sci Rep 2017; 7:9897. [PMID: 28851875 PMCID: PMC5575088 DOI: 10.1038/s41598-017-03693-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Accepted: 04/26/2017] [Indexed: 11/13/2022] Open
Abstract
Optimizing treatment planning is essential for advances in patient care and outcomes. Precisely tailored therapy for each patient remains a yearned-for goal. Cardiovascular modelling has the potential to simulate and predict the functional response before the actual intervention is performed. The objective of this study was to proof the validity of model-based prediction of haemodynamic outcome after aortic valve replacement. In a prospective study design virtual (model-based) treatment of the valve and the surrounding vasculature were performed alongside the actual surgical procedure (control group). The resulting predictions of anatomic and haemodynamic outcome based on information from magnetic resonance imaging before the procedure were compared to post-operative imaging assessment of the surgical control group in ten patients. Predicted vs. post-operative peak velocities across the valve were comparable (2.97 ± 1.12 vs. 2.68 ± 0.67 m/s; p = 0.362). In wall shear stress (17.3 ± 12.3 Pa vs. 16.7 ± 16.84 Pa; p = 0.803) and secondary flow degree (0.44 ± 0.32 vs. 0.49 ± 0.23; p = 0.277) significant linear correlations (p < 0.001) were found between predicted and post-operative outcomes. Between groups blood flow patterns showed good agreement (helicity p = 0.852, vorticity p = 0.185, eccentricity p = 0.333). Model-based therapy planning is able to accurately predict post-operative haemodynamics after aortic valve replacement. These validated virtual treatment procedures open up promising opportunities for individually targeted interventions.
Collapse
|
32
|
Reiber JHC, De Sutter J, Schoenhagen P, Stillman AE, Vande Veire NRL. Cardiovascular imaging 2016 in the International Journal of Cardiovascular Imaging. Int J Cardiovasc Imaging 2017; 33:761-770. [PMID: 28315986 PMCID: PMC5406479 DOI: 10.1007/s10554-017-1111-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Johan H C Reiber
- Department of Radiology, Division of Image Processing, Leiden University Medical Center, Leiden, The Netherlands.
| | - Johan De Sutter
- Department of Cardiology, AZ Maria Middelares Gent and University Gent, Ghent, Belgium
| | - Paul Schoenhagen
- Department of Radiology, The Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Arthur E Stillman
- Department of Radiology, Emory University Hospital, Atlanta, GA, USA
| | - Nico R L Vande Veire
- Department of Cardiology, AZ Maria Middelares Gent and Free University Brussels, Brussels, Belgium
| |
Collapse
|
33
|
Musa TA, Plein S, Greenwood JP. The role of cardiovascular magnetic resonance in the assessment of severe aortic stenosis and in post-procedural evaluation following transcatheter aortic valve implantation and surgical aortic valve replacement. Quant Imaging Med Surg 2016; 6:259-73. [PMID: 27429910 PMCID: PMC4929281 DOI: 10.21037/qims.2016.06.05] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Accepted: 04/02/2016] [Indexed: 01/20/2023]
Abstract
Degenerative aortic stenosis (AS) is the most common valvular disease in the western world with a prevalence expected to double within the next 50 years. International guidelines advocate the use of cardiovascular magnetic resonance (CMR) as an investigative tool, both to guide diagnosis and to direct optimal treatment. CMR is the reference standard for quantifying both left and right ventricular volumes and mass, which is essential to assess the impact of AS upon global cardiac function. Given the ability to image any structure in any plane, CMR offers many other diagnostic strengths including full visualisation of valvular morphology, direct planimetry of orifice area, the quantification of stenotic jets and in particular, accurate quantification of valvular regurgitation. In addition, CMR permits reliable and accurate measurements of the aortic root and arch which can be fundamental to appropriate patient management. There is a growing evidence base to indicate tissue characterisation using CMR provides prognostic information, both in asymptomatic AS patients and those undergoing intervention. Furthermore, a number of current clinical trials will likely raise the importance of CMR in routine patient management. This article will focus on the incremental value of CMR in the assessment of severe AS and the insights it offers following valve replacement.
Collapse
Affiliation(s)
- Tarique Al Musa
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Sven Plein
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - John P Greenwood
- Multidisciplinary Cardiovascular Research Centre (MCRC) & Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| |
Collapse
|