1
|
Tóth P, Arnóth B, Komlósi F, Szegedi N, Salló Z, Perge P, Osztheimer I, Merkely B, Gellér L, Nagy KV. Effect of early catheter ablation of atrial fibrillation in patients with heart failure. J Cardiovasc Electrophysiol 2024; 35:1471-1479. [PMID: 38803006 DOI: 10.1111/jce.16300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 04/15/2024] [Accepted: 04/28/2024] [Indexed: 05/29/2024]
Abstract
INTRODUCTION According to current guidelines, pulmonary vein isolation as first-line therapy should be considered for patients with atrial fibrillation (AF), however, optimal timing of the procedure is still unknown in patients with heart failure (HF). We aimed to evaluate the effect of early catheter ablation (CA) in patients with HF and left ventricular ejection fraction (LVEF) below 50%. METHODS We analyzed data from a structured registry comprising 227 patients with paroxysmal or persistent AF and HF with LVEF < 50% who underwent radiofrequency CA between 2015 and 2022. Early CA was defined as a procedure performed within 12 months of AF diagnosis. The median follow-up duration was 1748 (1176.3-2353.5) days, with a minimum follow-up of 365 days. Our endpoints were AF recurrence after a 3-months blanking period and all-cause mortality. RESULTS Among the 227 patients with a median age of 64.3 years, 97 (42.7%) experienced AF recurrence and 55 (24.2%) died during the follow-up period. The median LVEF was 40% for early CA and 38% for delayed CA (p = .053). Early CA significantly reduced AF recurrence (HR = 0.25 [0.15-0.42], p < .001), however, the timing of procedure did not affect all-cause mortality (p = .16). These findings were consistent regardless of AF subtype or the burden of comorbidities, as assessed by the CHA2DS2-VASc score. CONCLUSION The timing of CA of AF appears to be an important factor in patients with HF. Early CA reduced AF recurrence, although it does not impact all-cause mortality. We found similar results regardless of AF subtype or burden of comorbidities.
Collapse
Affiliation(s)
- Patrik Tóth
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Bence Arnóth
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Ferenc Komlósi
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Nándor Szegedi
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Zoltán Salló
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Péter Perge
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | | | - Béla Merkely
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - László Gellér
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | | |
Collapse
|
2
|
Bai Y, Jia R, Wang X, Chan J, Cui K. Association of left atrial wall thickness with recurrence after cryoballoon ablation of paroxysmal atrial fibrillation. J Interv Card Electrophysiol 2024; 67:657-667. [PMID: 37966658 DOI: 10.1007/s10840-023-01691-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 11/05/2023] [Indexed: 11/16/2023]
Abstract
BACKGROUND Transmural injury plays a role in successful atrial fibrillation ablation. The effect of left atrial wall thickness (LAWT) on the efficacy of radiofrequency ablation has been identified, but data on the relationship between LAWT and cryoballoon for paroxysmal atrial fibrillation (PAF) are lacking. We aim to explore the relationship between LAWT and recurrence after cryoballoon ablation (CBA). METHODS We studied 364 patients (mean age 62 years) with PAF who underwent a second-generation CBA and pre-procedure cardiac CTA. LAWT and left atrial volume index (LAVI) were obtained based on pre-procedure cardiac CTA measurements. Follow-up was at least 12 months and predictors of atrial tachyarrhythmia recurrence during follow-up were assessed. RESULTS Patients were followed up for a median of 19 (12-28) months, with an atrial tachyarrhythmia-free rate of 77.5% after cryoablation. Greater LAVI (50.0 ± 19.6 mL/m2 vs. 44.3 ± 15.4 mL/m2, P = 0.018) and greater LAWT (1.67 ± 0.24 vs. 1.46 ± 0.25 mm, P < 0.001) were associated with atrial tachyarrhythmia recurrence. The mean LAWT of PV antrum correlated with TTI (R = 0.252, P < 0.001). Adding LAWT to the established risk model improved both the discrimination and reclassification effects (IDI: 0.099, 95% CI: 0.065-0.134, P < 0.001; NRI: 0.685, 95% CI: 0.455-0.915, P < 0.001). In a multivariable Cox proportional hazard model, the mean LAWT of PV antrum (hazard ratio [HR]:3.657, 95%CI: 2.319-5.765, P < 0.001) was an independent predictor of atrial tachyarrhythmia recurrence after cryoablation. CONCLUSIONS The mean LAWT of PV antrum, obtained from preoperative measurements on CT, was associated with atrial tachyarrhythmia recurrence after cryoablation.
Collapse
Affiliation(s)
- Yixuan Bai
- Department of Cardiology, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Ruikun Jia
- Department of Cardiology, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Xinmeng Wang
- Department of Cardiology, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Juan Chan
- Department of Cardiology, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Kaijun Cui
- Department of Cardiology, West China Hospital, Sichuan University, No. 37, Guoxue Alley, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
3
|
Boga M, Orbán G, Perge P, Salló Z, Tanai E, Ferencz AB, Tóth P, Komlósi F, Osztheimer I, Nagy KV, Merkely B, Gellér L, Szegedi N. Adherence to the CLOSE Protocol and Low Baseline Generator Impedance Are Independent Predictors of Durable Pulmonary Vein Isolation. J Clin Med 2024; 13:1960. [PMID: 38610727 PMCID: PMC11012634 DOI: 10.3390/jcm13071960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 03/24/2024] [Accepted: 03/26/2024] [Indexed: 04/14/2024] Open
Abstract
Background: Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is predominantly attributed to pulmonary vein reconnection (PVR). Predictors of AF recurrence have been widely studied; however, data are scarce on procedural parameters that predict chronic PVR. We aimed to study PVR rates and predictors of PVR. Methods: We retrospectively included 100 patients who underwent repeated ablation due to AF recurrence after initial PVI with the CARTO system. PVR was determined during the repeated procedure by electrophysiological evaluation, and initial procedural characteristics predicting PVR were studied, including adherence to the CLOSE protocol, use of high power, first-pass isolation (FPI), and baseline generator impedance (BGI). Results: Thirty-eight patients underwent initial CLOSE-guided PVI, and sixty-two underwent initial non-CLOSE PVI. A repeat procedure was performed 23 ± 16 months after the initial procedure. In total, PVR was found in 192 of 373 PVs (51.5%), and all PVs were isolated in 17/100 (17%) patients. Factors associated with all PVs being isolated were adherence to the CLOSE protocol, a higher power setting, the presence of bilateral FPI, and lower BGI (88% vs. 28%, p < 0.0001; 37.5 W vs. 30 W, p = 0.0276; 88.2% vs. 40.4%, p = 0.0007; and 127.6 Ω vs. 136.6 Ω, p = 0.0027, respectively). In initial procedures with adherence to the CLOSE protocol, the FPI rate was significantly higher (73.7% vs. 25%, p < 0.0001), while there were no significant differences in terms of procedure time and left atrial dwell time (81 vs. 85 min, p = 0.83; and 60 vs. 58 min, p = 0.08, respectively). BGI ≥ 130 Ω (AUC = 0.7403, sensitivity: 77.1%, specificity: 68.8%, p = 0.0032) was associated with a significantly higher probability of PVR (OR = 6.757; p < 0.0001). In multivariable analysis, independent predictors for PVR were non-adherence to the CLOSE protocol and BGI ≥ 130 Ω. Conclusions: Our findings indicate that adherence to the CLOSE protocol and baseline generator impedance < 130 Ω during AF ablation are independent predictors of PVI durability.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | - Nándor Szegedi
- Heart and Vascular Center, Semmelweis University, 1085 Budapest, Hungary; (M.B.); (G.O.)
| |
Collapse
|
4
|
Orbán G, Dohy Z, Suhai FI, Nagy AI, Salló Z, Boga M, Kiss M, Kunze K, Neji R, Botnar R, Prieto C, Gellér L, Merkely B, Vágó H, Szegedi N. Use of a new non-contrast-enhanced BOOST cardiac MR sequence before electrical cardioversion or ablation of atrial fibrillation-a pilot study. Front Cardiovasc Med 2023; 10:1177347. [PMID: 37396587 PMCID: PMC10311645 DOI: 10.3389/fcvm.2023.1177347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 05/24/2023] [Indexed: 07/04/2023] Open
Abstract
Introduction Left atrial appendage (LAA) thrombus is the most common source of embolization in atrial fibrillation (AF). Transesophageal echocardiography (TEE) is the gold standard method for LAA thrombus exclusion. Our pilot study aimed to compare the efficacy of a new non-contrast-enhanced cardiac magnetic resonance (CMR) sequence (BOOST) with TEE for the detection of LAA thrombus and to evaluate the usefulness of BOOST images for planning radiofrequency catheter ablation (RFCA) compared with left atrial (LA) contrast-enhanced computed tomography (CT). We also attempted to assess the patients' subjective experiences with TEE and CMR. Methods Patients with AF undergoing either electrical cardioversion or RFCA were enrolled. Participants underwent pre-procedural TEE and CMR scans to evaluate LAA thrombus status and pulmonary vein anatomy. Patient experiences with TEE and CMR were assessed using a questionnaire developed by our team. Some patients scheduled for RFCA also had pre-procedural LA contrast-enhanced CT. In such cases, the operating physician was asked to subjectively define the quality of the CT and CMR scan on a scale of 1-10 (1 = worst, 10 = best) and comment on CMR's usefulness in RFCA planning. Results Seventy-one patients were enrolled. In 94.4%, both TEE and CMR excluded, and in 1 patient, both modalities reported the presence of LAA thrombus. In 1 patient, TEE was inconclusive, but CMR excluded LAA thrombus. In 2 patients, CMR could not exclude the presence of thrombus, but in 1 of those cases, TEE was also indecisive. During TEE, 67%, during CMR, only 1.9% of patients reported pain (p < 0.0001), and 89% would prefer CMR in case of a repeat examination. The quality of the left atrial contrast-enhanced CT scans was better compared with the image quality of the CMR BOOST sequence [8 (7-9) vs. 6 (5-7), p < 0.0001]. Still, the CMR images were useful for procedural planning in 91% of cases. Conclusion The new CMR BOOST sequence provides appropriate image quality for ablation planning. The sequence might be useful for excluding larger LAA thrombi; however, its accuracy in detecting smaller thrombi is limited. Most patients preferred CMR over TEE in this indication.
Collapse
Affiliation(s)
- Gábor Orbán
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Zsófia Dohy
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | | | - Anikó Ilona Nagy
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Zoltán Salló
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Márton Boga
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Máté Kiss
- Siemens Healthcare Hungary, Budapest, Hungary
| | - Karl Kunze
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| | - Radhouene Neji
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| | - Rene Botnar
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - László Gellér
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Béla Merkely
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Hajnalka Vágó
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Nándor Szegedi
- Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| |
Collapse
|
5
|
Tokavanich N, Prasitlumkum N, Kewcharoen J, Chokesuwattanaskul R, Phannajit J, Cheungpasitporn W, Akoum N, Ranjan R, Bunch TJ, Navaravong L. Network meta-analysis and systematic review comparing efficacy and safety between very high power short duration, high power short duration, and conventional radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol 2023; 34:869-879. [PMID: 36691892 DOI: 10.1111/jce.15831] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/11/2023] [Accepted: 01/17/2023] [Indexed: 01/25/2023]
Abstract
BACKGROUND High-power short-duration (HPSD) atrial fibrillation (AF) ablation with a power of 40-50 W was proved to be safe and effective. Very high-power short-duration (vHPSD) AF ablation is a novel method using >50 W to obtain more durable AF ablation. This study aimed to evaluate the efficacy and safety of vHPSD ablation compared with HPSD ablation and conventional power ablation. METHODS A literature search for studies that reported AF ablation outcomes, including short-term freedom from atrial arrhythmia, first-pass isolation (FPI) rate, procedure time, and major complications, was conducted utilizing MEDLINE, EMBASE, and Cochrane databases. All relevant studies were included in this analysis. A random-effects model of network meta-analysis and surface under cumulative ranking curve (SUCRA) were used to rank the treatment for all outcomes. RESULTS A total of 29 studies with 9721 patients were included in the analysis. According to the SUCRA analysis, HPSD ablation had the highest probability of maintaining sinus rhythm. Point estimation showed an odds ratio of 1.5 (95% confidence interval [CI]: 1.2-1.9) between HPSD ablation and conventional power ablation and an odds ratio of 1.3 (95% CI: 0.78-2.2) between vHPSD ablation and conventional power ablation. While the odds ratio of FPI between HPSD ablation and conventional power ablation was 3.6 (95% CI: 1.5-8.9), the odds ratio between vHPSD ablation and conventional power ablation was 2.2 (95% CI: 0.61-8.6). The procedure times of vHPSD and HPSD ablations were comparable and, therefore, shorter than that of conventional power ablation. Major complications were low in all techniques. CONCLUSION vHPSD ablation did not yield higher efficacy than HPSD ablation and conventional power ablation. With the safety concern, vHPSD ablation outcomes were comparable with those of other techniques.
Collapse
Affiliation(s)
- Nithi Tokavanich
- Sparrow Hospital, Michigan State University, East Lansing, Michigan, USA
| | - Narut Prasitlumkum
- Department of Cardiology, University of California Riverside, Riverside, California, USA
| | - Jakrin Kewcharoen
- Division of Cardiovascular Medicine, Loma Linda University Health, Loma Linda, California, USA
| | - Ronpichai Chokesuwattanaskul
- Division of Cardiovascular Medicine, Department of Medicine, Cardiac Center, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Jeerath Phannajit
- Division of Clinical Epidemiology and Division of Nephrology, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | | | - Nazem Akoum
- Cardiology Department, University of Washington Medical Center, Seattle, Washington, USA
| | - Ravi Ranjan
- Division of Cardiovascular Medicine, University of Utah School of Medicine, Salt Lake City, Utah, USA
| | - T Jared Bunch
- Division of Cardiovascular Medicine, University of Utah School of Medicine, Salt Lake City, Utah, USA
| | - Leenhapong Navaravong
- Division of Cardiovascular Medicine, University of Utah School of Medicine, Salt Lake City, Utah, USA
| |
Collapse
|
6
|
Jin S, Lin W, Fang X, Liao H, Zhan X, Fu L, Jiang J, Ye X, Liu H, Chen Y, Pu S, Wu S, Deng H, Xue Y. High-Power, Short-Duration Ablation under the Guidance of Relatively Low Ablation Index Values for Paroxysmal Atrial Fibrillation: Long-Term Outcomes and Characteristics of Recurrent Atrial Arrhythmias. J Clin Med 2023; 12:jcm12030971. [PMID: 36769620 PMCID: PMC9917927 DOI: 10.3390/jcm12030971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/23/2023] [Accepted: 01/24/2023] [Indexed: 01/31/2023] Open
Abstract
OBJECTIVE The purpose of this study was to evaluate the difference in effectiveness and safety of high-power, short-duration (HPSD) radiofrequency catheter ablation (RFA) guided by relatively low ablation index (AI) values and conventional RFA in paroxysmal atrial fibrillation (PAF) patients. METHODS The HPSD RFA strategy (40-50 W, AI 350-400 for anterior, 320-350 for posterior wall; n = 547) was compared with the conventional RFA strategy (25-40 W, without AI; n = 396) in PAF patients who underwent their first ablation. Propensity-score matching analyses were used to compare the outcomes of the two groups while controlling for confounders. RESULTS After using propensity-score matching analysis, the HPSD group showed a higher early recurrence rate (22.727% vs. 13.636%, p = 0.003), similar late recurrence rate, and comparable safety (p = 0.604) compared with the conventional group. For late recurrent atrial arrhythmia types, the rate of regular atrial tachycardia was significantly higher in the HPSD group (p = 0.013). Additionally, the rate of chronic pulmonary vein reconnection and non-pulmonary vein triggers during repeat procedures was similar in both groups. CONCLUSIONS For PAF patients, compared with the conventional RFA strategy, the HPSD RFA strategy at relatively low AI settings had a higher early recurrence rate, similar long-term success rate, and comparable safety.
Collapse
Affiliation(s)
- Shuyu Jin
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Weidong Lin
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Xianhong Fang
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Hongtao Liao
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Xianzhang Zhan
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Lu Fu
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Junrong Jiang
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Xingdong Ye
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Huiyi Liu
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Yanlin Chen
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Sijia Pu
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
- School of Medicine, South China University of Technology, Guangzhou 510006, China
| | - Shulin Wu
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Hai Deng
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
- Correspondence: (H.D.); (Y.X.)
| | - Yumei Xue
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
- Correspondence: (H.D.); (Y.X.)
| |
Collapse
|
7
|
Atrial fibrillation ablation: the position of computed tomography in pre-procedural imaging. CURRENT ISSUES IN PHARMACY AND MEDICAL SCIENCES 2022. [DOI: 10.2478/cipms-2022-0022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Abstract
Atrial fibrillation (AF) is the most common supraventricular arrhythmia. Despite significant advances in its treatment, it still remains one of the leading causes of cardiovascular morbidity and mortality. In the last two decades, pulmonary vein isolation (PVI) was developed as the most effective treatment option. The reported effectiveness of a single ablation procedure ranges from 40% to 69% with single, and up to 88% with repeated procedures, with acceptable safety profile. The PubMed database was searched, using terms including ‘atrial fibrillation ablation’, ‘pulmonary vein isolation’, ‘computed tomography’, ‘pulmonary vein anatomy’ and ‘ovality index’. Papers were reviewed for relevance and scientific merit. Different imaging techniques are used for pre-procedural assessment of left atrial (LA) anatomy, of which computed tomography (CT) is the most common. It allows assessing pulmonary vein (PV) anatomy, the LA wall thickness in different regions and the left atrial appendage (LAA) anatomy, together with excluding the presence of intracardiac thrombi. Pre-procedural PVs imaging is important regardless of the selected ablation technique, however, cryoballoon (CB) ablation seems to be particularly anatomy-dependent. Additionally, CT also permits assessment of several PVs characteristics (geometry, dimensions, angulations, the ostium area, orientation and ovality index (OI), which are essential for the patients’ qualification and designing the strategy of AF ablation. In this paper, we have reviewed the role of CT imaging in patients undergoing ablation procedure due to recurrent/symptomatic atrial fibrillation. Moreover, we discussed the relevant literature.
Collapse
|