Sass JO, Henke P, Mitrovic A, Weinmann M, Kluess D, Johannsen J, Sellin ML, Lembke U, Reimer D, Lork C, Jonitz-Heincke A, Bader R. Multifunctional Hybrid Material for Endoprosthetic Implants Based on Alumina-Toughened Zirconia Ceramics and Additively Manufactured TiNbTa Alloys. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1838. [PMID: 38673194 PMCID: PMC11051168 DOI: 10.3390/ma17081838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/10/2024] [Accepted: 04/11/2024] [Indexed: 04/28/2024]
Abstract
Aseptic implant loosening after a total joint replacement is partially influenced by material-specific factors when cobalt-chromium alloys are used, including osteolysis induced by wear and corrosion products and stress shielding. Here, we aim to characterize a hybrid material consisting of alumina-toughened zirconia (ATZ) ceramics and additively manufactured Ti-35Nb-6Ta (TiNbTa) alloys, which are joined by a glass solder. The structure of the joint, the static and fatigue shear strength, the influence of accelerated aging, and the cytotoxicity with human osteoblasts are characterized. Furthermore, the biomechanical properties of the functional demonstrators of a femoral component for total knee replacements are evaluated. The TiNbTa-ATZ specimens showed a homogenous joint with statistically distributed micro-pores and a slight accumulation of Al-rich compounds at the glass solder-TiNbTa interface. Shear strengths of 26.4 ± 4.2 MPa and 38.2 ± 14.4 MPa were achieved for the TiNbTa-ATZ and Ti-ATZ specimens, respectively, and they were not significantly affected by the titanium material used, nor by accelerated aging (p = 0.07). All of the specimens survived 107 cycles of shear loading to 10 MPa. Furthermore, the TiNbTa-ATZ did not impair the proliferation and metabolic activity of the human osteoblasts. Functional demonstrators made of TiNbTa-ATZ provided a maximum bearable extension-flexion moment of 40.7 ± 2.2 Nm. The biomechanical and biological properties of TiNbTa-ATZ demonstrate potential applications for endoprosthetic implants.
Collapse
Affiliation(s)
- Jan-Oliver Sass
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany; (P.H.)
| | - Paul Henke
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany; (P.H.)
| | - Aurica Mitrovic
- ZM Praezisionsdentaltechnik GmbH, Breite Str. 16, D-18057 Rostock, Germany (C.L.)
| | | | - Daniel Kluess
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany; (P.H.)
- INNOPROFF GmbH, Joachim-Jungius-Straße 9, D-18059 Rostock, Germany
| | - Jan Johannsen
- Fraunhofer Research Institution for Additive Manufacturing Technologies IAPT, Am Schleusengraben 14, D-21029 Hamburg, Germany;
| | - Marie-Luise Sellin
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany; (P.H.)
| | - Ulrich Lembke
- DOT GmbH, Charles-Darwin-Ring 1A, D-18059 Rostock, Germany
| | - Daniel Reimer
- FMZ GmbH, Charles-Darwin-Ring 3A, D-18059 Rostock, Germany
| | - Cornelia Lork
- ZM Praezisionsdentaltechnik GmbH, Breite Str. 16, D-18057 Rostock, Germany (C.L.)
| | - Anika Jonitz-Heincke
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany; (P.H.)
| | - Rainer Bader
- Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, D-18057 Rostock, Germany; (P.H.)
| |
Collapse
|
2
|
Febrer-Nafría M, Dreyer MJ, Maas A, Taylor WR, Smith CR, Hosseini Nasab SH. Knee kinematics are primarily determined by implant alignment but knee kinetics are mainly influenced by muscle coordination strategy. J Biomech 2023; 161:111851. [PMID: 37907050 DOI: 10.1016/j.jbiomech.2023.111851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 10/19/2023] [Accepted: 10/22/2023] [Indexed: 11/02/2023]
Abstract
Implant malalignment has been reported to be a primary reason for revision total knee arthroplasty (TKA). In addition, altered muscle coordination patterns are commonly observed in TKA patients, which is thought to alter knee contact loads. A comprehensive understanding of the influence of surgical implantation and muscle recruitment strategies on joint contact mechanics is crucial to improve surgical techniques, increase implant longevity, and inform rehabilitation protocols. In this study, a detailed musculoskeletal model with a 12 degrees of freedom knee was developed to represent a TKA subject from the CAMS-Knee datasets. Using motion capture and ground reaction force data, a level walking cycle was simulated and the joint movement and loading patterns were estimated using a novel technique for concurrent optimization of muscle activations and joint kinematics. In addition, over 12'000 Monte Carlo simulations were performed to predict knee contact mechanics during walking, considering numerous combinations of implant alignment and muscle activation scenarios. Validation of our baseline simulation showed good agreement between the model kinematics and loading patterns against the in vivo data. Our analyses reveal a considerable impact of implant alignment on the joint kinematics, while variation in muscle activation strategies mainly affects knee contact loading. Moreover, our results indicate that high knee compressive forces do not necessarily originate from extreme kinematics and vice versa. This study provides an improved understanding of the complex inter-relationships between loading and movement patterns resulting from different surgical implantation and muscle coordination strategies and presents a validated framework towards population-based modelling in TKA.
Collapse
Affiliation(s)
- Míriam Febrer-Nafría
- Institute for Biomechanics, ETH Zürich, Switzerland; Department of Mechanical Engineering, Universitat Politècnica de Catalunya, Spain
| | - Michael J Dreyer
- Institute for Biomechanics, ETH Zürich, Switzerland; Laboratory for Mechanical Systems Engineering, Empa, Dübendorf, Switzerland
| | - Allan Maas
- Department of Orthopaedic and Trauma Surgery, Ludwig Maximilians University Munich, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, Munich, Germany; Research and Development, Aesculap AG, Tuttlingen, Germany
| | | | - Colin R Smith
- Institute for Biomechanics, ETH Zürich, Switzerland; Steadman Philippon Research Institute, Vail, USA
| | | |
Collapse
|
3
|
Dammer RH, Zietz C, Bader R. A Comparison of Wear Patterns on Retrieved and Simulator-Tested Total Knee Replacements. J Funct Biomater 2022; 13:256. [PMID: 36412896 PMCID: PMC9680524 DOI: 10.3390/jfb13040256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/10/2022] [Accepted: 11/16/2022] [Indexed: 11/22/2022] Open
Abstract
Aseptic implant loosening is the most common reason for revision surgery after total knee replacement. This is associated with adverse biological reactions to wear debris from the articulating implant components. To predict the amount of wear debris generated in situ, standard wear testing of total knee replacement (TKR) is carried out before its clinical use. However, wear data reported on retrievals of total knee replacement (TKR) revealed significant discrepancies compared with standard wear simulator studies. Therefore, the aim of the present study was to compare the wear patterns on identical posterior-cruciate-retaining TKR designs by analyzing retrieved and experimentally tested implants. The identification and classification of wear patterns were performed using 21 retrieved ultra-high-molecular-weight-polyethylene (UHMW-PE) inserts and four sets of inserts of identical design and material tested in a knee wear simulator. These four sets had undergone different worst-case conditions and a standard test in a wear simulator according to ISO 14243-1. Macroscopic and microscopic examinations of the polyethylene inserts were performed, including the determination of seven modes of wear that correspond to specific wear patterns, the calculation of wear areas, and the classification of the damage over the whole articulating area. Retrieved and standard wear simulator-tested UHMW-PE inserts showed significant differences in wear area and patterns. The total wear areas and the damage score were significantly larger on the retrievals (52.3% versus 23.9%, 32.7 versus 22.7). Furthermore, the range of wear patterns found on the retrievals was not reproducible in the simulator-tested inserts. However, good correspondence was found with the simulator-tested polyethylene inserts under worst-case conditions (third body wear), i.e., deep wear areas could be replicated according to the in vivo situation compared with other wear test scenarios. Based on the findings presented here, standard simulator testing can be used to directly compare different TKR designs but is limited in the prediction of their in situ wear. Preclinical wear testing may be adjusted by worst-case conditions to improve the prediction of in situ performance of total knee implants in the future.
Collapse
Affiliation(s)
- Rebecca H. Dammer
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Strasse 142, 18057 Rostock, Germany
| | | | | |
Collapse
|
4
|
Mell SP, Wimmer MA, Jacobs JJ, Lundberg HJ. Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters. J Mech Behav Biomed Mater 2022; 125:104939. [PMID: 34740015 PMCID: PMC8710043 DOI: 10.1016/j.jmbbm.2021.104939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/18/2021] [Accepted: 10/25/2021] [Indexed: 01/03/2023]
Abstract
Currently, preclinical mechanical wear testing of total knee replacements (TKRs) is done using ideally aligned components using standardized TKR level walking under either force or displacement-control regimes. To understand the influence of implant alignment and testing control regime, we studied the effect of nine component alignment parameters on TKR volumetric wear in silico. We used a computational framework combining Latin Hypercube sampling design of experiments, finite element analysis, and a numerical model of polyethylene wear, to create a predictive model of how component alignment affects wear rate for each control regime. Nine component alignment parameters were investigated, five femoral variables and four tibial variables. To investigate perturbations of the nine implant alignment variables, two separate 300-point designs were executed, one for each control regime. The results were then used to generate surrogate statistical models using stepwise multiple linear regression. Wear at the neutral position was 4.5mm3/million cycle and 8.6mm3/million cycle for displacement and force-control, respectively. Stepwise multiple linear regression surrogate models were highly significant for each control regime, but force-control generated a stronger predictive model, with a higher R2, more included terms, and a lower RMSE. Both models predicted transverse plane rotational mismatch can lead to large changes in predicted wear; a transverse plane alignment mismatch of 15° can elicit a change in wear of up to 5mm3/million cycle, almost double that of neutral alignment. Therefore, transverse plane alignment is particularly important when considering failure of the implant due to wear.
Collapse
|
5
|
Rheologic Behavior of Bovine Calf Serum. MATERIALS (BASEL, SWITZERLAND) 2021; 14:ma14102538. [PMID: 34068363 PMCID: PMC8153264 DOI: 10.3390/ma14102538] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/06/2021] [Accepted: 05/08/2021] [Indexed: 12/23/2022]
Abstract
Recent studies have illuminated the rheological behavior of synovial fluid and the role of protein and hyaluronan (HA). However, with respect to artificial joint replacement in standardized wear simulations, bovine serum is used as fluid test medium. Little is known about the rheological characteristics of bovine serum, which are needed for precise tribological investigations. The steady shear viscosity η of bovine calf serum is determined for protein concentrations used in standardized wear simulations depending on shear rate γ˙ and temperature T. Additionally, the density of the serum is determined for both protein concentrations. The results show shear thinning behavior of bovine calf serum with a nearly Newtonian behavior in the range of high shear rates. Within the range of high shear rates, mean viscosities of η = 0.82-0.88 mPa·s were found for protein concentrations of 20 g/L and mean viscosities of η = 0.88-0.94 mPa·s for 30 g/L, decreasing with temperature. Densities of 1.004-1.005 g/cm3 and 1.007-1.008 g/cm3 were found for 20 and 30 g/L protein concentrations, respectively.
Collapse
|
6
|
Woiczinski M, Schröder C, Paulus A, Kistler M, Jansson V, Müller PE, Weber P. Varus or valgus positioning of the tibial component of a unicompartmental fixed-bearing knee arthroplasty does not increase wear. Knee Surg Sports Traumatol Arthrosc 2020; 28:3016-3021. [PMID: 31690992 DOI: 10.1007/s00167-019-05761-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 10/15/2019] [Indexed: 12/15/2022]
Abstract
PURPOSE Higher revision rates were shown in varus- or valgus-positioned tibias in unicompartmental knee arthroplasty (UKA), but more than 15% of UKA prostheses are implanted with more than 5° of varus or valgus. This study aimed to analyze the wear rate in UKA when implanting the tibial component in either varus or valgus position versus a neutral placement at 90° to the tibial anatomical axis. The study hypothesized that a 5° varus or valgus positioning of the tibial plateau will generate less wear compared to a neutral alignment. METHODS Wear was experimentally analyzed on a medial anatomical fixed-bearing unicompartmental knee prosthesis (Univation, Aesculap, Germany) in vitro with a customized, four-station, servohydraulic knee wear simulator, reproducing the walking cycle. The forces, loading and range of motion were applied as specified in the ISO 14243-1:2002, 5 million cycles were analyzed. The tibial components of the medial prostheses were inserted in a neutral position, with 5° varus, and 5° valgus (n = 3, each group). RESULTS The wear rate decreased significantly with a 5° varus positioning (6.30 ± 1.38 mg/million cycles) and a 5° valgus positioning (4.96 ± 2.47 mg/million cycles) compared to the neutral position (12.16 ± 1.26 mg/million cycles) (p < 0.01 for the varus and the valgus position). The wear area on the inlay was slightly reduced in the varus and valgus group. CONCLUSION A varus or valgus "malpositioning" up to 5° will not lead to an increased wear. Wear was even less because of the reduced articulating contact area between the inlay and the femur. A slight varus positioning of the tibial component (parallel to the anatomical joint line) positioning can be advocated from a point of wear. LEVEL OF EVIDENCE Experimental study.
Collapse
Affiliation(s)
- Matthias Woiczinski
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital, Ludwig-Maximilians-University (LMU), Campus Großhadern, Marchioninistr. 15, 81377, Munich, Germany
| | - Christian Schröder
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital, Ludwig-Maximilians-University (LMU), Campus Großhadern, Marchioninistr. 15, 81377, Munich, Germany
| | - Alexander Paulus
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital, Ludwig-Maximilians-University (LMU), Campus Großhadern, Marchioninistr. 15, 81377, Munich, Germany
| | - Manuel Kistler
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital, Ludwig-Maximilians-University (LMU), Campus Großhadern, Marchioninistr. 15, 81377, Munich, Germany
| | - Volkmar Jansson
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital, Ludwig-Maximilians-University (LMU), Campus Großhadern, Marchioninistr. 15, 81377, Munich, Germany
| | - Peter E Müller
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital, Ludwig-Maximilians-University (LMU), Campus Großhadern, Marchioninistr. 15, 81377, Munich, Germany
| | - Patrick Weber
- Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital, Ludwig-Maximilians-University (LMU), Campus Großhadern, Marchioninistr. 15, 81377, Munich, Germany. .,ECOM-Excellent Center of Medicine, Arabellastr, 17, 81925, Munich, Germany.
| |
Collapse
|
7
|
Mell SP, Wimmer MA, Lundberg HJ. Sensitivity of total knee replacement wear to variability in motion and load input: A parametric finite element analysis study. J Orthop Res 2020; 38:1538-1549. [PMID: 32458460 PMCID: PMC9595431 DOI: 10.1002/jor.24755] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Revised: 03/30/2020] [Accepted: 05/25/2020] [Indexed: 02/04/2023]
Abstract
Polyethylene wear remains a contributor to long term failure in total knee replacements (TKRs). Advances in materials have improved polyethylene wear rates, therefore further wear reductions require a better understanding of patient-specific factors that lead to wear. Variability of gait within patients is considerable and could lead to significant variability in wear rates that cannot be predicted by standard testing methods. An in-silico study was performed to investigate the influence of gait variability on TKR polyethylene wear. Nine characteristic peaks within the load and motion profiles used for TKR wear testing were varied 75% to 125% from baseline (ISO-14243-3:2014) to generate 310 unique waveforms. Wear was calculated for 1-million cycles using a finite element TKR wear model. From the results, a surrogate model was developed using multiple linear regression, and used to predict how wear changes due to dispersion of motion and force peaks within a) ±5%, the maximum allowable input tolerance of ISO, and b) ±25%, more reflective of patient gait inter-variability. The range of wear within the ±5% tolerance was 0.65 mm3 /million cycles and was 3.24 mm3 /million cycles within the ±25% variability more in line with the dispersion observed within patients. Although no one kinematic or kinetic peak dominated variability in TKR volumetric wear, variability within flexion/extension peaks were the largest contributor to wear rate variability. Interaction between the peaks of different waveforms was also important. This study, and future studies incorporating patient-specific data, could help to explain the connection between patient-specific gait factors and wear rates.
Collapse
|
8
|
Mell SP, Fullam S, Wimmer MA, Lundberg HJ. Computational Parametric Studies for Preclinical Evaluation of Total Knee Replacements. LECTURE NOTES IN COMPUTATIONAL VISION AND BIOMECHANICS 2020. [DOI: 10.1007/978-3-030-43195-2_6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
9
|
Mell SP, Wimmer MA, Lundberg HJ. The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3. J Biomech 2019; 88:104-112. [PMID: 30940359 DOI: 10.1016/j.jbiomech.2019.03.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 03/08/2019] [Accepted: 03/18/2019] [Indexed: 01/16/2023]
Abstract
A leading cause of long-term failure of total knee replacements (TKRs) is osteolysis caused by polyethylene wear particles. The current gold standard for preclinical wear testing of TKRs is mechanical knee simulators. The definition of the femoral center of flexion-extension rotation (CoR) has been identified as one possible source of variability within TKR wear tests, since the femoral curvature varies from distal to posterior. The magnitude of the influence on wear due to changes in location of femoral CoR has not been investigated in depth. During this study, a computational framework utilizing finite element analysis for modelling wear of TKRs was developed and used to investigate the influence of the location of femoral CoR on TKR polyethylene wear during standardized displacement controlled testing (ISO 14243-3:2014). The study was carried out using a 40-point Latin Hypercube Design of Experiments approach. Volumetric wear was highly correlated to femoral CoR in both the superior/inferior and anterior/posterior directions, with a stronger relationship in the superior/inferior direction. In addition, wear scars showing linear penetration were examined, with large differences in simulations at the extreme ends of the sampling region. In this study, it was found that variations in the location of the femoral center of rotation can represent a large source of variability in the preclinical testing and evaluation of the wear performance of total knee replacements. This study represents the first attempt at quantifying the effect on wear of different femoral center of rotations across a large sampling space.
Collapse
|
10
|
Puente Reyna AL, Fritz B, Schwiesau J, Schilling C, Summer B, Thomas P, Grupp TM. Metal ion release barrier function and biotribological evaluation of a zirconium nitride multilayer coated knee implant under highly demanding activities wear simulation. J Biomech 2018; 79:88-96. [DOI: 10.1016/j.jbiomech.2018.07.043] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 07/20/2018] [Accepted: 07/31/2018] [Indexed: 12/13/2022]
|
11
|
Bian YY, Zhou L, Zhou G, Jin ZM, Xin SX, Hua ZK, Weng XS. Study on biocompatibility, tribological property and wear debris characterization of ultra-low-wear polyethylene as artificial joint materials. J Mech Behav Biomed Mater 2018; 82:87-94. [DOI: 10.1016/j.jmbbm.2018.03.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 02/27/2018] [Accepted: 03/05/2018] [Indexed: 10/17/2022]
|
12
|
Brockett CL, Abdelgaied A, Haythornthwaite T, Hardaker C, Fisher J, Jennings LM. The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study. Proc Inst Mech Eng H 2018; 230:429-39. [PMID: 27160561 PMCID: PMC4873730 DOI: 10.1177/0954411916645134] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Accepted: 03/08/2016] [Indexed: 11/15/2022]
Abstract
Advancements in knee replacement design, material and sterilisation processes have provided improved clinical results. However, surface wear of the polyethylene leading to osteolysis is still considered the longer-term risk factor. Experimental wear simulation is an established method for evaluating the wear performance of total joint replacements. The aim of this study was to investigate the influence of simulation input conditions, specifically input kinematic magnitudes, waveforms and directions of motion and position of the femoral centre of rotation, on the wear performance of a fixed-bearing total knee replacement through a combined experimental and computational approach. Studies were completed using conventional and moderately cross-linked polyethylene to determine whether the influence of these simulation input conditions varied with material. The position of the femoral centre of rotation and the input kinematics were shown to have a significant influence on the wear rates. Similar trends were shown for both the conventional and moderately cross-linked polyethylene materials, although lower wear rates were found for the moderately cross-linked polyethylene due to the higher level of cross-linking. The most important factor influencing the wear was the position of the relative contact point at the femoral component and tibial insert interface. This was dependent on the combination of input displacement magnitudes, waveforms, direction of motion and femoral centre of rotation. This study provides further evidence that in order to study variables such as design and material in total knee replacement, it is important to carefully control knee simulation conditions. This can be more effectively achieved through the use of displacement control simulation.
Collapse
Affiliation(s)
- Claire L Brockett
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Abdellatif Abdelgaied
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Tony Haythornthwaite
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | | | - John Fisher
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Louise M Jennings
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
13
|
Fabry C, Zietz C, Baumann A, Ehall R, Bader R. High wear resistance of femoral components coated with titanium nitride: a retrieval analysis. Knee Surg Sports Traumatol Arthrosc 2018; 26:2630-2639. [PMID: 28528349 PMCID: PMC6105138 DOI: 10.1007/s00167-017-4578-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Accepted: 05/15/2017] [Indexed: 11/28/2022]
Abstract
PURPOSE The objective of this study was to evaluate the in vivo wear resistance of cobalt-chromium femoral components coated with titanium nitride (TiN). Our null hypothesis was that the surface damage and the thickness of the TiN coating do not correlate with the time in vivo. METHODS Twenty-five TiN-coated bicondylar femoral retrievals with a mean implantation period of 30.7 ± 11.7 months were subjected to an objective surface damage analysis with a semi-quantitative assessment method. A visual examination of scratches, indentations, notches and coating breakthroughs of the surfaces was performed. The roughness and the coating thickness of the TiN coating were evaluated in the main articulation regions. RESULTS Narrow scratches and indentations in the range of low flexion angles on the retrieval surfaces were the most common modes of damage. There was no evidence of delamination on the articulation surface but rather at the bottom of isolated severe indentations or notches. An analysis of three retrievals revealed a coating breakthrough in the patellofemoral joint region, resulting from patella maltracking and a dislocation. The arithmetical mean roughness of the TiN surface slightly increased with the implantation period. In contrast, the maximum peak height of the roughness profile was reduced at the condyles of the retrieved components in comparison with new, unused surfaces. No significant association between the coating thickness and implantation period was determined. Moreover, the measured values were retained in the range of the initial coating thickness even after several years of in vivo service. CONCLUSIONS As was demonstrated by the results of this study, the surface damage to the TiN coating did not deteriorate with the implantation period. The calculated damage scores and the measured coating thickness in particular both confirmed that the TiN coating provides low wear rates. Our findings support the use of wear-resistant TiN-coated components in total knee arthroplasty with the objective of reducing the risk of aseptic loosening. However, in terms of TiN-coated femoral components, particular attention should be paid to a correct patellar tracking in order to avoid wear propagation at the implant.
Collapse
Affiliation(s)
- Christian Fabry
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Doberaner Str. 142, 18057 Rostock, Germany
- DOT GmbH, Charles-Darwin-Ring 1a, 18059 Rostock, Germany
| | - Carmen Zietz
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Doberaner Str. 142, 18057 Rostock, Germany
| | - Axel Baumann
- DOT GmbH, Charles-Darwin-Ring 1a, 18059 Rostock, Germany
| | - Reinhard Ehall
- Graz Ragnitz Private Hospital, Berthold-Linder-Weg 15, 8047 Graz, Austria
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Doberaner Str. 142, 18057 Rostock, Germany
| |
Collapse
|
14
|
Grupp TM, Fritz B, Kutzner I, Schilling C, Bergmann G, Schwiesau J. Vitamin E stabilised polyethylene for total knee arthroplasty evaluated under highly demanding activities wear simulation. Acta Biomater 2017; 48:415-422. [PMID: 27789345 DOI: 10.1016/j.actbio.2016.10.031] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 09/30/2016] [Accepted: 10/22/2016] [Indexed: 01/12/2023]
Abstract
As total knee arthroplasty (TKA) patients are getting more active, heavier and younger and structural material fatigue and delamination of tibial inserts becomes more likely in the second decade of good clinical performance it appears desirable to establish advanced pre-clinical test methods better characterizing the longterm clinical material behaviour. The questions of our study were 1) Is it possible to induce subsurface delamination and striated pattern wear on standard polyethylene TKA gliding surfaces? 2) Can we distinguish between γ-inert standard polyethylene (PEstand.30kGy) as clinical reference and vitamin E stabilised materials (PEVit.E30kGy & PEVit.E50kGy)? 3) Is there an influence of the irradiation dose (30vs 50kGy) on oxidation and wear behaviour? Clinical relevant artificial ageing (ASTM F2003; 2weeks) of polyethylene CR fixed TKA inserts and oxidation index measurements were performed by Fourier transform infrared spectroscopy prior testing. The oxidation index was calculated in accordance with ISO 5834-4:2005 from the area ratio of the carbonyl peak (between 1650 and 1850cm-1) to the reference peak for polyethylene (1370cm-1). Highly demanding patient activities (HDA) measured in vivo were applied for 5million knee wear cycles in a combination of 40% stairs up, 40% stairs down, 10% level walking, 8% chair raising and 2% deep squatting with up to 100° flexion. After 3.0mc all standard polyethylene gliding surfaces developed noticeable areas of progressive delamination. Cumulative gravimetric wear was 355.9mg for PEstand.30kGy, 28.7mg for PEVit.E30kGy and 26.5mg for PEVit.E50kGy in HDA knee wear simulation. Wear rates were 12.4mg/mc for PEstand.30kGy in the linear portion (0-2mc), 5.6mg/mc for PEVit.E30kGy and 5.3mg/mc for PEVit.E50kGy. In conclusion, artificial ageing of standard polyethylene to an oxidation index of 0.7-0.95 in combination with HDA knee wear simulation, is able to create subsurface delamination, structural material fatigue in vitro, whereas for the vitamin-E-blended materials no evidence of progressive wear, fatigue or delamination was found. STATEMENT OF SIGNIFICANCE As total knee arthroplasty patients are getting more active, heavier and younger and structural material fatigue and delamination of polyethylene tibial inserts becomes more likely in the second decade of good clinical performance, it appears desirable to establish advanced pre-clinical test methods better characterizing the longterm clinical material behaviour. Various studies reported in literature attempted to artificially create delamination during in vitro knee wear simulation. We combined artificial ageing to clinically observed oxidation of gamma inert and vitamin E stabilised polyethylene inserts and highly demanding patient activities knee wear simulation based on in vivo load data. With this new method we were able to create clinically relevant subsurface delamination and structural material fatigue on standard polyethylene inserts in vitro.
Collapse
|