1
|
Fasogbon IV, Ondari EN, Deusdedit T, Rangasamy L, Krishnan S, Aja PM. Point-of-care potentials of lateral flow-based field screening for Mycoplasma bovis infections: a literature review. Biol Methods Protoc 2024; 9:bpae034. [PMID: 38835856 PMCID: PMC11147795 DOI: 10.1093/biomethods/bpae034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 05/09/2024] [Accepted: 05/17/2024] [Indexed: 06/06/2024] Open
Abstract
Point-of-care (POC) field screening for tools for Mycoplasma bovis (M. bovis) is still lacking due to the requirement for a simple, robust field-applicable test that does not entail specialized laboratory equipment. In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines, this review identifies the methodologies that were retrieved based on our search strategy that have been reported for the diagnosis of m. bovis infection between 2014 and diagnostics. A search criterion was generated to curate 103 articles, which were reduced in number (to 46), following the screening guidelines of PRISMA. The 43 articles included in the study present 25 different assay methods. The assay methods were grouped as microbiological culture, serological assay, PCR-based assay, LAMP-based assay, NGS-based assay, or lateral flow assay. We, however, focus our discussion on the three lateral flow-based assays relative to others, highlighting the advantages they present above the other techniques and their potential applicability as a POC diagnostic test for M. bovis infections. We therefore call for further research on developing a lateral flow-based screening tool that could revolutionize the diagnosis of M. bovis infection.
Collapse
Affiliation(s)
- Ilemobayo V Fasogbon
- Department of Biochemistry, Kampala International University-Western Campus, Bushenyi 41201, Uganda
- Centre for Biomaterials, Cellular and Molecular Theranostics (CBCMT), Vellore Institute of Technology, Vellore 632014, India
| | - Erick N Ondari
- Department of Biological Sciences, School of Pure & Applied Sciences, Kisii University, Kisii 40200, Kenya
| | - Tusubira Deusdedit
- Department of Biochemistry, Mbarara University of Science and Technology, Mbarara 40301, Uganda
| | - Loganathan Rangasamy
- Centre for Biomaterials, Cellular and Molecular Theranostics (CBCMT), Vellore Institute of Technology, Vellore 632014, India
| | - Sasirekha Krishnan
- Centre for Biomaterials, Cellular and Molecular Theranostics (CBCMT), Vellore Institute of Technology, Vellore 632014, India
| | - Patrick M Aja
- Department of Biochemistry, Kampala International University-Western Campus, Bushenyi 41201, Uganda
| |
Collapse
|
2
|
Liu H, Ji F, Ding SN. Carbon black as a colorimetric label for an immunochromatographic test strip for severe fever with thrombocytopenia syndrome virus detection. Analyst 2023. [PMID: 37194303 DOI: 10.1039/d3an00515a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
To combat the ongoing threat posed by severe fever with thrombocytopenia syndrome virus (SFTSV), especially in underserved areas, there is an urgent need for an affordable and reliable point-of-care diagnostic tool. This study presents a carbon black-based immunochromatographic test strip (CB-ICTS) for the detection of SFTSV, which is both quick and easy to operate. The study optimized the specific steps for carbon black-labeled antibodies, as well as the amount of carbon black and anti-SFTSV antibody used. Under optimal experimental conditions, the linear range and limit of detection of the CB-ICTS were evaluated using different concentrations of SFTSV standard samples. The detection range of the CB-ICTS for SFTSV was found to be 0.1-1000 ng mL-1, with a limit of detection of 100 pg mL-1. The precision and accuracy of the CB-ICTS were assessed by examining spiked healthy human serum samples, which displayed recoveries ranging from 91.58 to 105.4% with a coefficient of variation of less than 11%. This work evaluated the specificity of the CB-ICTS using various biomarkers (CA125, AFP, CA199, CEA, and HCG) and demonstrated that the CB-ICTS is highly specific for detecting SFTSV, suggesting its potential for the early diagnosis of SFTSV. In addition, the study evaluated the CB-ICTS in serum samples from patients with SFTSV, and the results were highly consistent with those detected by the polymerase chain reaction (PCR) method. Overall, this study demonstrates the feasibility and effectiveness of using the CB-ICTS as a reliable point-of-care diagnostic tool for the early detection of SFTSV.
Collapse
Affiliation(s)
- Hao Liu
- Jiangsu Province Hi-Tech Key Laboratory for Bio-Medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, P. R. China.
| | - Fang Ji
- Jiangsu King's Luck Brewery Joint-Stock Co., Ltd, Lianshui 223411, China
| | - Shou-Nian Ding
- Jiangsu Province Hi-Tech Key Laboratory for Bio-Medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, P. R. China.
| |
Collapse
|
3
|
Qiao W, He B, Ren W, Zhao R, Suo Z, Yan H, Xu Y, Wei M, Jin H. Colloidal Au sphere and nanoflower-based immunochromatographic strips for sensitive detection of zearalenone in cereals. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3831-3839. [PMID: 36168770 DOI: 10.1039/d2ay01365g] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Zearalenone (ZEN), also known as an F-2 toxin, is a secondary metabolite in the toxic Fusarium species with estrogen properties. ZEN and its derivatives can cause developmental and reproductive disorders in humans and other mammals. In this study, colloidal Au spheres (AuSPs) and Au nanoflowers (AuNFs) were used as signal labels to detect ZEN in cereals, and the critical factors affecting the sensitivity of the immunochromatographic strip (ICS), namely the volume of antigen, antibody, and probe quantities were optimized and compared in detail. Since the large specific surface area of AuNFs reduces the steric hindrance of proteins, it is more conducive to improving the fixation rate of antibodies and proteins. Compared with the traditional colloidal AuSP immunochromatographic strip (AuSP-ICS), the volume of the antibody used in the AuNF immunochromatographic strip (AuNF-ICS) was 0.6 times that in the AuSPs-ICS. At the same antigen volume, a lower amount of probe can achieve the desired visual detection effect and higher sensitivity. For the AuNF-ICS, the limit of detection (LOD) was as low as 0.08 ng mL-1. ZEN could be detected quickly and accurately from 0.08-10.2 ng mL-1. And the AuNF-ICS had a high degree of specificity and sensitivity to ZEN. In summary, the AuNF-ICS serves as a valuable tool in large-scale on-site detection of ZEN.
Collapse
Affiliation(s)
- Weili Qiao
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China.
| | - Baoshan He
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China.
| | - Wenjie Ren
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China.
| | - Renyong Zhao
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China.
| | - Zhiguang Suo
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China.
| | - Haoyang Yan
- School of International Education, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China
| | - Yiwei Xu
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China.
| | - Min Wei
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China.
| | - Huali Jin
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, P. R. China.
| |
Collapse
|
4
|
Kim DM, Yoo SM. Colorimetric Systems for the Detection of Bacterial Contamination: Strategy and Applications. BIOSENSORS 2022; 12:bios12070532. [PMID: 35884335 PMCID: PMC9313054 DOI: 10.3390/bios12070532] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 07/10/2022] [Accepted: 07/13/2022] [Indexed: 12/19/2022]
Abstract
Bacterial contamination is a public health concern worldwide causing enormous social and economic losses. For early diagnosis and adequate management to prevent or treat pathogen-related illnesses, extensive effort has been put into the development of pathogenic bacterial detection systems. Colorimetric sensing systems have attracted increasing attention due to their simple and single-site operation, rapid signal readout with the naked eye, ability to operate without external instruments, portability, compact design, and low cost. In this article, recent trends and advances in colorimetric systems for the detection and monitoring of bacterial contamination are reviewed. This article focuses on pathogen detection strategies and technologies based on reaction factors that affect the color change for visual readout. Reactions used in each strategy are introduced by dividing them into the following five categories: external pH change-induced pH indicator reactions, intracellular enzyme-catalyzed chromogenic reactions, enzyme-like nanoparticle (NP)-catalyzed substrate reactions, NP aggregation-based reactions, and NP accumulation-based reactions. Some recently developed colorimetric systems are introduced, and their challenges and strategies to improve the sensing performance are discussed.
Collapse
Affiliation(s)
- Dong-Min Kim
- Center for Applied Life Science, Hanbat National University, Daejeon 34158, Korea;
| | - Seung-Min Yoo
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Korea
- Correspondence:
| |
Collapse
|
5
|
Abstract
Analytical devices for point-of-care diagnoses are highly desired and would improve quality of life when first diagnoses are made early and pathologies are recognized soon. Lateral flow tests (LFTs) are such tools that can be easily performed without specific equipment, skills, or experiences. This review is focused on the use of LFT in point-of-care diagnoses. The principle of the assay is explained, and new materials like nanoparticles for labeling, new recognition molecules for interaction with an analyte, and new additional instrumentation like signal scaling by a smartphone camera are described and discussed. Advantages of the LFT devices as well as their limitations are described and discussed here considering actual papers that are properly cited.
Collapse
|