1
|
Shi J, Ding S, Li C, Chen G, Du F, Wang S, Yue A, Ren K, Yang Z, Xu P, Dong J, Zhao J, Tang Z. Ultrafast DNA detection based on turn-back loop primer-accelerated LAMP (TLAMP). Anal Chim Acta 2024; 1321:343041. [PMID: 39155098 DOI: 10.1016/j.aca.2024.343041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 07/08/2024] [Accepted: 07/30/2024] [Indexed: 08/20/2024]
Abstract
Rapid DNA detection is a long-pursuing goal in molecular detection, especially in combating infectious diseases. Loop-mediated isothermal amplification (LAMP) is a robust and prevailing DNA detection method in pathogen detection, which has been drawing broad interest in improving its performance. Herein, we reported a new strategy and developed a new LAMP variant named TLAMP with a superior amplification rate. In this strategy, the turn-back loop primers (TLPs) were devised by ingeniously extending the 5' end of the original loop primer, which conferred the new role of being the inner primer for TLPs while retaining its original function as the loop primer. In theory, based on the bifunctional TLPs, a total of eight basic dumbbell-like structures and four cyclic amplification pathways were produced to significantly enhance the amplification efficiency of TLAMP. With the enhancing effect of TLPs, TLAMP exhibited a significantly reduced amplification-to-result time compared to the conventional six-primer LAMP (typically 1 h), enabling rapid DNA detection within 20 min. Furthermore, TLAMP proved to be about 10 min faster than the fast LAMP variants reported so far, while still presenting comparable sensitivity and higher repeatability. Finally, TLAMP successfully achieved an ultrafast diagnosis of Monkeypox virus (MPXV), capable of detecting as few as 10 copies (0.67copies/μL) of pseudovirus within 20 min using real-time fluorescence assay or within 30 min using a colorimetric assay, suggesting that the proposed TLAMP offers a sensitive, specific, reliable, and, most importantly, ultrafast DNA detection method when facing the challenges posed by infectious diseases.
Collapse
Affiliation(s)
- Jinyi Shi
- Shanxi Agricultural University, Dept Basic Sci, Taigu, 030801, Shanxi, PR China; Natural Products Research Center, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Sheng Ding
- School of Clinical Medical College & Affiliated Hospital, Chengdu University, Chengdu, 610052, PR China
| | - Chen Li
- Shanxi Agricultural University, Dept Basic Sci, Taigu, 030801, Shanxi, PR China
| | - Gangyi Chen
- Natural Products Research Center, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, PR China
| | - Feng Du
- Natural Products Research Center, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, PR China
| | - Sifan Wang
- Shanxi Agricultural University, Dept Basic Sci, Taigu, 030801, Shanxi, PR China
| | - Aiqin Yue
- Shanxi Agricultural University, Dept Basic Sci, Taigu, 030801, Shanxi, PR China
| | - Kaiyuan Ren
- Natural Products Research Center, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, PR China
| | - Zhirong Yang
- People's Hospital of De Yang City, Deyang, 618099, PR China
| | - Pei Xu
- People's Hospital of De Yang City, Deyang, 618099, PR China
| | - Juan Dong
- Natural Products Research Center, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, PR China.
| | - Jinzhong Zhao
- Shanxi Agricultural University, Dept Basic Sci, Taigu, 030801, Shanxi, PR China.
| | - Zhuo Tang
- Natural Products Research Center, Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, PR China.
| |
Collapse
|
2
|
Bai Y, Xu P, Li S, Wang D, Zhang K, Zheng D, Yue D, Zhang G, He S, Li Y, Zou H, Deng Y. Signal amplification strategy of DNA self-assembled biosensor and typical applications in pathogenic microorganism detection. Talanta 2024; 272:125759. [PMID: 38350248 DOI: 10.1016/j.talanta.2024.125759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 01/17/2024] [Accepted: 02/06/2024] [Indexed: 02/15/2024]
Abstract
Biosensors have emerged as ideal analytical devices for various bio-applications owing to their low cost, convenience, and portability, which offer great potential for improving global healthcare. DNA self-assembly techniques have been enriched with the development of innovative amplification strategies, such as dispersion-to-localization of catalytic hairpin assembly, and dumbbell hybridization chain reaction, which hold great significance for building biosensors capable of realizing sensitive, rapid and multiplexed detection of pathogenic microorganisms. Here, focusing primarily on the signal amplification strategies based on DNA self-assembly, we concisely summarized the strengths and weaknesses of diverse isothermal nucleic acid amplification techniques. Subsequently, both single-layer and cascade amplification strategies based on traditional catalytic hairpin assembly and hybridization chain reaction were critically explored. Furthermore, a comprehensive overview of the recent advances in DNA self-assembled biosensors for the detection of pathogenic microorganisms is presented to summarize methods for biorecognition and signal amplification. Finally, a brief discussion is provided about the current challenges and future directions of DNA self-assembled biosensors.
Collapse
Affiliation(s)
- Yuxin Bai
- College of Medical Technology, Chengdu University of Traditional Chinese Medicine, 610075, Chengdu, China
| | - Pingyao Xu
- Department of Clinical Laboratory, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610041, Chengdu, China
| | - Shi Li
- Department of Clinical Laboratory, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610041, Chengdu, China
| | - Dongsheng Wang
- Department of Clinical Laboratory, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610041, Chengdu, China
| | - Kaijiong Zhang
- Department of Clinical Laboratory, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610041, Chengdu, China
| | - Dongming Zheng
- College of Medical Technology, Chengdu University of Traditional Chinese Medicine, 610075, Chengdu, China
| | - Daifan Yue
- College of Medical Technology, Chengdu University of Traditional Chinese Medicine, 610075, Chengdu, China
| | - Guiji Zhang
- Department of Clinical Laboratory, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610041, Chengdu, China
| | - Shuya He
- Department of Clinical Laboratory, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610041, Chengdu, China
| | - Yan Li
- College of Medical Technology, Chengdu University of Traditional Chinese Medicine, 610075, Chengdu, China.
| | - Haimin Zou
- Department of Clinical Laboratory, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610041, Chengdu, China.
| | - Yao Deng
- Department of Clinical Laboratory, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, 610041, Chengdu, China.
| |
Collapse
|
3
|
Kumar A, Singh N, Anvikar AR, Misra G. Monkeypox virus: insights into pathogenesis and laboratory testing methods. 3 Biotech 2024; 14:67. [PMID: 38357674 PMCID: PMC10861412 DOI: 10.1007/s13205-024-03920-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Accepted: 01/07/2024] [Indexed: 02/16/2024] Open
Abstract
The monkeypox virus (MPXV) is a zoonotic pathogen that transmits between monkeys and humans, exhibiting clinical similarities with the smallpox virus. Studies on the immunopathogenesis of MPXV revealed that an initial strong innate immune response is elicited on viral infection that subsequently helps in circumventing the host defense. Once the World Health Organization (WHO) declared it a global public health emergency in July 2022, it became essential to clearly demarcate the MPXV-induced symptoms from other viral infections. We have exhaustively searched the various databases involving Google Scholar, PubMed, and Medline to extract the information comprehensively compiled in this review. The primary focus of this review is to describe the diagnostic methods for MPXV such as polymerase chain reaction (PCR), and serological assays, along with developments in viral isolation, imaging techniques, and next-generation sequencing. These innovative technologies have the potential to greatly enhance the accuracy of diagnostic procedures. Significant discoveries involving MPXV immunopathogenesis have also been highlighted. Overall, this will be a knowledge repertoire that will be crucial for the development of efficient monitoring and control strategies in response to the MPXV infection helping clinicians and researchers in formulating healthcare strategies.
Collapse
Affiliation(s)
- Anoop Kumar
- National Institute of Biologicals, A-32, Sector-62, Institutional Area, Noida, U.P. 201309 India
| | - Neeraj Singh
- National Institute of Biologicals, A-32, Sector-62, Institutional Area, Noida, U.P. 201309 India
| | - Anupkumar R. Anvikar
- National Institute of Biologicals, A-32, Sector-62, Institutional Area, Noida, U.P. 201309 India
| | - Gauri Misra
- National Institute of Biologicals, A-32, Sector-62, Institutional Area, Noida, U.P. 201309 India
- Head Molecular Diagnostics and COVID-19 Kit Testing Laboratory, National Institute of Biologicals (Ministry of Health and Family Welfare), Noida, U.P. 201309 India
| |
Collapse
|
4
|
Manzo M, Serra A, Pedone E, Pirone L, Scognamiglio V, De Felice M, De Falco M. DNA Polymerase I Large Fragment from Deinococcus radiodurans, a Candidate for a Cutting-Edge Room-Temperature LAMP. Int J Mol Sci 2024; 25:1392. [PMID: 38338670 PMCID: PMC10855757 DOI: 10.3390/ijms25031392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 01/17/2024] [Accepted: 01/22/2024] [Indexed: 02/12/2024] Open
Abstract
In recent years, the loop-mediated isothermal amplification (LAMP) technique, designed for microbial pathogen detection, has acquired fundamental importance in the biomedical field, providing rapid and precise responses. However, it still has some drawbacks, mainly due to the need for a thermostatic block, necessary to reach 63 °C, which is the BstI DNA polymerase working temperature. Here, we report the identification and characterization of the DNA polymerase I Large Fragment from Deinococcus radiodurans (DraLF-PolI) that functions at room temperature and is resistant to various environmental stress conditions. We demonstrated that DraLF-PolI displays efficient catalytic activity over a wide range of temperatures and pH, maintains its activity even after storage under various stress conditions, including desiccation, and retains its strand-displacement activity required for isothermal amplification technology. All of these characteristics make DraLF-PolI an excellent candidate for a cutting-edge room-temperature LAMP that promises to be very useful for the rapid and simple detection of pathogens at the point of care.
Collapse
Affiliation(s)
- Marilena Manzo
- Institute of Bioscience and BioResources, National Research Council, Via Pietro Castellino 111, 80131 Naples, Italy
| | - Assunta Serra
- Institute of Bioscience and BioResources, National Research Council, Via Pietro Castellino 111, 80131 Naples, Italy
| | - Emilia Pedone
- Institute of Biostructures and Bioimaging, National Research Council, Via Pietro Castellino 111, 80131 Naples, Italy
| | - Luciano Pirone
- Institute of Biostructures and Bioimaging, National Research Council, Via Pietro Castellino 111, 80131 Naples, Italy
| | - Viviana Scognamiglio
- Institute of Crystallography, National Research Council, Department of Chemical Sciences and Materials Technologies, Via Salaria km 29.300, Monterotondo, 00015 Rome, Italy
| | - Mariarita De Felice
- Institute of Bioscience and BioResources, National Research Council, Via Pietro Castellino 111, 80131 Naples, Italy
| | - Mariarosaria De Falco
- Institute of Bioscience and BioResources, National Research Council, Via Pietro Castellino 111, 80131 Naples, Italy
| |
Collapse
|
5
|
Cheng R, Li L, Zhen S, Liu H, Wu Z, Wang Y, Wang Z. Rapid Detection of Staphylococcus aureus in Milk and Pork via Immunomagnetic Separation and Recombinase Polymerase Amplification. Microbiol Spectr 2023; 11:e0224922. [PMID: 36847574 PMCID: PMC10101137 DOI: 10.1128/spectrum.02249-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 02/04/2023] [Indexed: 03/01/2023] Open
Abstract
Separation processes using immunomagnetic beads (IMBs) are advantageous for the rapid detection of Staphylococcus aureus (S. aureus). Herein, a novel method, based on immunomagnetic separation using IMBs and recombinase polymerase amplification (RPA), was employed to detect S. aureus strains in milk and pork. IMBs were formed by the carbon diimide method using rabbit anti-S. aureus polyclonal antibodies and superparamagnetic carboxyl-Fe3O4 MBs. The average capture efficiency for 2.5 to 2.5 × 105 (CFU)/mL gradient dilution of S. aureus with 6 mg of IMBs within 60 min were a range of 62.74 to 92.75%. The detection sensitivity of the IMBs-RPA method in artificially contaminated samples was 2.5 × 101 CFU/mL. The entire detection process was completed within 2.5 h, including bacteria capture, DNA extraction, amplification, and electrophoresis. Among 20 actual samples, one case of raw milk sample and two cases of pork samples were tested positive using the established IMBs-RPA method, which were verified by the standard S. aureus inspection procedure. Therefore, the novel method shows potential for food safety supervision owing to its short detection time, higher sensitivity, and high specificity. IMPORTANCE Our study established IMBs-RPA method, which simplified the steps of bacteria separation, shortened the detection time, and realized the convenient detection of S. aureus in milk and pork samples. IMBs-RPA method was also suitable for the detection of other pathogens, providing a new method for food safety monitoring and a favorable basis for rapid and early diagnosis of diseases.
Collapse
Affiliation(s)
- Runan Cheng
- Beijing Key Laboratory of Traditional Chinese Veterinary Medicine, Animal Science and Technology College, Beijing University of Agriculture, Beijing, China
| | - Lei Li
- Beijing Key Laboratory of Traditional Chinese Veterinary Medicine, Animal Science and Technology College, Beijing University of Agriculture, Beijing, China
| | - Sihui Zhen
- Beijing Key Laboratory of Traditional Chinese Veterinary Medicine, Animal Science and Technology College, Beijing University of Agriculture, Beijing, China
| | - Honglei Liu
- Beijing Key Laboratory of Traditional Chinese Veterinary Medicine, Animal Science and Technology College, Beijing University of Agriculture, Beijing, China
| | - Zhouhui Wu
- Beijing Key Laboratory of Traditional Chinese Veterinary Medicine, Animal Science and Technology College, Beijing University of Agriculture, Beijing, China
| | - Yu Wang
- Beijing Key Laboratory of Traditional Chinese Veterinary Medicine, Animal Science and Technology College, Beijing University of Agriculture, Beijing, China
| | - Zhen Wang
- Beijing Key Laboratory of Traditional Chinese Veterinary Medicine, Animal Science and Technology College, Beijing University of Agriculture, Beijing, China
| |
Collapse
|
6
|
Liang Y, Zhang C. A novel PCR-free and label-free cloth-based DNA sensor for sensitive and rapid detection of Escherichia coli. Anal Chim Acta 2023; 1239:340630. [PMID: 36628741 DOI: 10.1016/j.aca.2022.340630] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 11/14/2022] [Indexed: 11/17/2022]
Abstract
BACKGROUND As is known to all, pathogenic bacteria have a serious impact on human health. The development of sensitive, simple, rapid and low-cost bacterial detection method is necessary. Nowadays, some conventional methods (such as plate count, polymerase chain reaction (PCR) and immunological techniques) can not meet the above needs. This work was aimed at providing a new method for addressing these unmet needs. RESULT This study proposed a novel PCR-free and label-free DNA sensor based on multiple linear hybridization chain reaction (ML-HCR) and cloth-based closed bipolar electrochemiluminescence for sensitive and rapid detection of Escherichia coli (E. coli). The target DNA can be obtained from the E. coli genomic DNA by using the restriction enzyme instead of PCR. The auxiliary probe-triggered ML-HCR is carried out with continuous hybridization of two hairpin DNA, and as a result the double stranded DNA is formed to provide a large number of binding sites for Ru(bpy)32+. The whole detection is PCR-free and label-free, and thus the detection procedure is easier and faster. Under optimized conditions, the linear detection range was from 102 to 107 CFU/mL, and the detection limit was low to 38 CFU/mL. In addition, the proposed DNA sensor has an acceptable selectivity, stability and reproducibility, and is successfully applied to detect E. coli in milk samples with the recoveries from 96.24% to 105.98%. SIGNIFICANCE The proposed DNA sensor has broad application prospects in the fields of bacterial detection and gene diagnose. Further, this method has potential to be extended for establishing miniaturized, integrated, and automated detection system.
Collapse
Affiliation(s)
- Yi Liang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Chunsun Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
| |
Collapse
|
7
|
Development of a Loop-Mediated Isothermal Amplification Method for Rapid and Visual Detection of Monkeypox Virus. Microbiol Spectr 2022; 10:e0271422. [PMID: 36154444 PMCID: PMC9603857 DOI: 10.1128/spectrum.02714-22] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Monkeypox virus (MPXV) is a human pathogenic virus that belongs to the genus Orthopoxvirus. In 2022, MPXV caused an unprecedented number of infections in many countries. As it is difficult to distinguish MPXV from other pathogens by its symptoms in the early stage of infection, a rapid and reliable assay for MPXV detection is needed. In this study, we developed a loop-mediated isothermal amplification (LAMP) assay for the specific detection of MPXV and evaluated its application in simulated clinical samples. The A27L-1 and F3L-1 primer sets were identified as the optimal primers, and 63°C was the most appropriate reaction temperature for sequence amplification. The detection limits of the LAMP assay using primer sets A27L-1 and F3L-1 were both 20 copies/reaction mixture, which were >100-fold higher in terms of sensitivity, compared with conventional PCR. The LAMP assay findings were negative for all 21 non-MPXV pathogens, confirming the high specificity of our assay. All three types of simulated clinical samples were clearly identified by our LAMP assay, and the detection limits were consistent with the sensitivity results, indicating efficient clinical sample identification. Our rapid and reliable MPXV LAMP assay could be useful for MPXV detection and on-site diagnosis, especially in primary hospitals and rural areas. IMPORTANCE MPXV outbreaks rapidly grew in the first half of 2022, and this virus has been recognized as an increasing public health threat, particularly in the context of the COVID-19 pandemic. Thus, developing reliable and fast detection methods for MPXV is necessary.
Collapse
|
8
|
Development and Evaluation of Duplex MIRA-qPCR Assay for Simultaneous Detection of Staphylococcus aureus and non-aureus Staphylococci. Microorganisms 2022; 10:microorganisms10091734. [PMID: 36144336 PMCID: PMC9502308 DOI: 10.3390/microorganisms10091734] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 08/22/2022] [Accepted: 08/24/2022] [Indexed: 11/24/2022] Open
Abstract
Staphylococcus spp., especially Staphylococcus aureus (S. aureus), is an important pathogen in hospital-acquired infection and food poisoning. Here, we developed a multienzyme isothermal rapid amplification combined with duplex quantitative PCR (duplex MIRA-qPCR) method, which can simultaneously detect the S. aureus species-specific conserved gene FMN-bgsfp and the Staphylococcus genus-specific conserved gene tuf. This assay enabled the amplification of DNA within 20 min at a constant temperature of 39 °C. Specificity analysis indicated that all nine common Staphylococcus species were positive and non-Staphylococcus spp. were negative for tuf gene, whereas S. aureus was positive, non-aureus Staphylococci species and non-Staphylococcus spp. were negative for FMN-bgsfp gene, suggesting that duplex MIRA-qPCR exhibited high specificity. Meanwhile, the sensitivity was tested and the limit of detection (LoD) was 3 × 102 CFU/mL. The coefficient variation values ranged from 0.13% to 2.09%, indicating that the assay had good repeatability. Furthermore, all the nine common Staphylococcus species (including S. aureus) could be detected from four kinds of simulated samples and the LoD of S. aureus was 8.56 × 103 CFU/mL. In conclusion, the duplex MIRA-qPCR has advantages of stronger specificity, lower detection threshold, shorter detection time, and simpler operation, which is an effective tool to detect S. aureus and non-aureus Staphylococci spp. infections rapidly.
Collapse
|
9
|
Shen Z, Liu Y, Chen L. Qualitative and Quantitative Detection of Potentially Virulent Vibrio parahaemolyticus in Drinking Water and Commonly Consumed Aquatic Products by Loop-Mediated Isothermal Amplification. Pathogens 2021; 11:10. [PMID: 35055958 PMCID: PMC8781264 DOI: 10.3390/pathogens11010010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 12/12/2021] [Accepted: 12/15/2021] [Indexed: 11/16/2022] Open
Abstract
Vibrio parahaemolyticus can cause acute gastroenteritis, wound infection, and septicemia in humans. In this study, a simple, specific, and user-friendly diagnostic tool was developed for the first time for the qualitative and quantitative detection of toxins and infection process-associated genes opaR, vpadF, tlh, and ureC in V. parahaemolyticus using the loop-mediated isothermal amplification (LAMP) technique. Three pairs of specific inner, outer, and loop primers were designed for targeting each of these genes, and the results showed no cross-reaction with the other common Vibrios and non-Vibrios pathogenic bacteria. Positive results in the one-step LAMP reaction (at 65 °C for 45 min) were identified by a change to light green and the emission of bright green fluorescence under visible light and UV light (302 nm), respectively. The lowest limit of detection (LOD) for the target genes ranged from 1.46 × 10-5 to 1.85 × 10-3 ng/reaction (25 µL) for the genomic DNA, and from 1.03 × 10-2 to 1.73 × 100 CFU/reaction (25 µL) for the cell culture of V. parahaemolyticus. The usefulness of the developed method was demonstrated by the fact that the bacterium could be detected in water from various sources and commonly consumed aquatic product samples. The presence of opaR and tlh genes in the Parabramis pekinensis intestine indicated a risk of potentially virulent V. parahaemolyticus in the fish.
Collapse
Affiliation(s)
| | | | - Lanming Chen
- Key Laboratory of Quality and Safety Risk Assessment for Aquatic Products on Storage and Preservation (Shanghai), Ministry of Agriculture and Rural Affairs of the People’s Republic of China, College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; (Z.S.); (Y.L.)
| |
Collapse
|