1
|
Peng ZX, He Y, Yu LJ, Hao ZY, Li TM, Gu LK, Wang L. The influence of in situ purification system on pathogen in the river fed by the drainage of sewage plant. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:29930-29938. [PMID: 38598157 DOI: 10.1007/s11356-024-33162-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 03/27/2024] [Indexed: 04/11/2024]
Abstract
An in situ integrated system, consisting of ecological floating islands (EFI), ecological riverbeds (ER), and ecological filter dams (EFD), was built in a ditch only receiving the effluent of sewage plant; the effect of in situ technologies on the distribution of aquatic pathogen was investigated. The results showed the aquatic pathogen decreased along the ditch. Specifically, the relative abundance of Legionella, Aeromonas, and Acinetobacter decreased from 0.032, 0.035, and 0.26 to 0.026%, 0.012%, and 0.08%, respectively. Sedimentation, filtration, and sorption (provided by plant roots and biofilms on substrates) were principal processes for the removal. The nitrogen removal bacteria to prevent the potential risk of eutrophication were also evaluated. The EFI and ER were the dominant sites for Nitrosomonas (34.96%, 32.84%) and Nitrospira (35.74%, 54.73%) enrichment, while EFI and EFD facilitated the enrichment of denitrification bacteria. Notably, the relative abundance of endogenous denitrifiers (DNB-en) (including Dechloromonas at 9.72%, Thermomonas at 0.58%, and Saccharibacteria at 2.55%) exceeded those of exogenous denitrifiers (DNB-ex) (Thauera at 0.20%, Staphylococcus at 0.005%, and Rhodobacter at 0.27%). This study demonstrated that the in situ integrated system was effective in reducing the abundance of pathogens in the drainage channel, and the deficiency of DNB-ex and carbon sources made nitrate removal difficult.
Collapse
Affiliation(s)
- Zhao-Xu Peng
- School of Water Conservancy and Transportation, Zhengzhou University, Zhengzhou, 450001, China
| | - Yu He
- School of Water Conservancy and Transportation, Zhengzhou University, Zhengzhou, 450001, China
| | - Lu-Ji Yu
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, 450001, China
| | - Zi-Yao Hao
- Research Center for Environmental Planning and Assessment of Zhengzhou University, Zhengzhou, 450001, China
| | - Ting-Mei Li
- Research Center for Environmental Planning and Assessment of Zhengzhou University, Zhengzhou, 450001, China
| | - Li-Kun Gu
- Henan University of Engineering, Zhengzhou, 450001, China
| | - Li Wang
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, 450001, China.
| |
Collapse
|
2
|
Marras L, Bertolino G, Sanna A, Carraro V, Coroneo V. Legionella spp. Monitoring in the Water Supply Systems of Accommodation Facilities in Sardinia, Italy: A Two-Year Retrospective Analysis. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:6722. [PMID: 37754582 PMCID: PMC10530320 DOI: 10.3390/ijerph20186722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 08/25/2023] [Accepted: 08/30/2023] [Indexed: 09/28/2023]
Abstract
Travel-associated Legionnaires' disease is a significant public health concern worldwide. A high number of cases are reported every year among travellers who stay at guest houses, hotels, and spas. Indeed, hot water systems, showers, and air-conditioning systems can be contaminated by Legionella, which grows at 25-42 °C. Studies have shown that in Sardinia, especially during the summer months, the water circulation in the hotels' pipes is exposed to extremely high temperatures. As a result, this study was conducted to assess the colonization of hotel water systems by Legionella in Sardinia, concerning a recent EU directive 2020/2184 for drinking water with a limit of 1000 CFU /L. Methods. A total of 112 accommodation facilities were analyzed, of which 61.3% were found to be colonized with Legionella, and out of a total of 807 samples, 32.5% were positive for Legionella presence. The results showed a higher number of positive samples in the summer season. This was also associated with the higher concentration presence of >1000 CFU/L in the samples. Consequently, this study confirms that local hotel operators should improve their water safety and prevention plans, especially in spring and summer.
Collapse
Affiliation(s)
- Luisa Marras
- Department of Medical Sciences and Public Health, University of Cagliari, 09124 Cagliari, Italy
| | - Giacomo Bertolino
- Pharmaceutical Department, Azienda Ospedaliero, Universitaria di Cagliari, 09123 Cagliari, Italy;
| | - Adriana Sanna
- Department of Medical Sciences and Public Health, University of Cagliari, 09124 Cagliari, Italy
| | - Valentina Carraro
- Department of Medical Sciences and Public Health, University of Cagliari, 09124 Cagliari, Italy
| | - Valentina Coroneo
- Department of Medical Sciences and Public Health, University of Cagliari, 09124 Cagliari, Italy
| |
Collapse
|
3
|
Rakić A, Vukić Lušić D, Jurčev Savičević A. Influence of Metal Concentration and Plumbing Materials on Legionella Contamination. Microorganisms 2022; 10:1051. [PMID: 35630493 PMCID: PMC9147233 DOI: 10.3390/microorganisms10051051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Revised: 05/15/2022] [Accepted: 05/17/2022] [Indexed: 12/07/2022] Open
Abstract
Legionella colonization of water supply pipes is a significant public health problem. The objective of this work was to evaluate Legionella colonization in hotel hot water systems and to investigate the relationship between metal concentrations, piping materials (galvanized iron pipes and plastic pipes), and Legionella proliferation. Concentrations of calcium and magnesium ions and the presence of Legionella pneumophila were determined in a total of 108 water samples from the hot water systems of four hotels in Split-Dalmatia County over a 12-month period, and additional data on piping materials were collected. L. pneumophila was isolated in 23.1% of all samples-in 28.8% (15/52) of water samples from galvanized iron pipes and in 17.8% (10/56) of samples from plastic pipes. L. pneumophila serogroups 2-14 were isolated from all samples. This study found higher prevalence of L. pneumophila at higher concentrations of Ca and Mg ions (except for Mg and plastic pipes). The metal parts of the water supply may be important factors in Legionella contamination due to the possibility of lime scale or roughness of the pipes. Higher Ca and Mg ion concentrations increased the risk of Legionella colonization.
Collapse
Affiliation(s)
- Anita Rakić
- Public Health Institute of Split-Dalmatia County, Vukovarska 46, 21000 Split, Croatia;
| | - Darija Vukić Lušić
- Department of Environmental Health, Faculty of Medicine, University of Rijeka, Braće Branchetta 20, 51000 Rijeka, Croatia
- Department of Environmental Health, Teaching Institute of Public Health of Primorje-Gorski Kotar County, Krešimirova 52a, 51000 Rijeka, Croatia
- Center for Advanced Computing and Modeling, University of Rijeka, Radmile Matejčić 2, 51000 Rijeka, Croatia
| | - Anamarija Jurčev Savičević
- Public Health Institute of Split-Dalmatia County, Vukovarska 46, 21000 Split, Croatia;
- Department of Health Studies, University of Split, 35 P.P. 464, Ruđera Boškovića Street, 21000 Split, Croatia
| |
Collapse
|
4
|
Niculita-Hirzel H, Vanhove AS, Leclerc L, Girardot F, Pourchez J, Allegra S. Risk Exposure to Legionella pneumophila during Showering: The Difference between a Classical and a Water Saving Shower System. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19063285. [PMID: 35328980 PMCID: PMC8955837 DOI: 10.3390/ijerph19063285] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 03/01/2022] [Accepted: 03/08/2022] [Indexed: 02/04/2023]
Abstract
The increase in legionellosis incidence in the general population in recent years calls for a better characterization of the sources of infection, such as showering. Water-efficient shower systems that use water-atomizing technology have been shown to emit slightly more inhalable particles in the range of bacterial sizes than the traditional systems; however, the actual rate of bacterial emission remains poorly documented. The aim of this study was to assess the aerosolisation rate of the opportunistic water pathogen Legionella pneumophila during showering with one shower system representative of each technology. To achieve this objective, we performed controlled experiments inside a glove box and determined the emitted dose and viability of airborne Legionella. The bioaerosols were sampled with a Coriolis® Delta air sampler and the total number of viable (cultivable and noncultivable) Legionella was determined by flow cytometry and culture. We found that the rate of viable and cultivable Legionella aerosolized from the water jet was similar between the two showerheads: the viable fraction represents 0.02% of the overall bacteria present in water, while the cultivable fraction corresponds to only 0.0005%. The two showerhead models emitted a similar ratio of airborne Legionella viable and cultivable per volume of water used. Therefore, the risk of exposure to Legionella is not expected to increase significantly with the new generation of water-efficient showerheads.
Collapse
Affiliation(s)
- Hélène Niculita-Hirzel
- Department Work, Heath & Environment, Center for Primary Care and Public Health (Unisanté), University of Lausanne, Route de la Corniche 2, CH-1066 Epalinges-Lausanne, Switzerland
- Correspondence:
| | - Audrey S. Vanhove
- EVS-ISTHME UMR 5600, CNRS, University Jean Monnet of Saint-Etienne, F-42023 Saint-Etienne, France; (A.S.V.); (F.G.); (S.A.)
| | - Lara Leclerc
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023 Saint-Etienne, France; (L.L.); (J.P.)
| | - Françoise Girardot
- EVS-ISTHME UMR 5600, CNRS, University Jean Monnet of Saint-Etienne, F-42023 Saint-Etienne, France; (A.S.V.); (F.G.); (S.A.)
| | - Jérémie Pourchez
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023 Saint-Etienne, France; (L.L.); (J.P.)
| | - Séverine Allegra
- EVS-ISTHME UMR 5600, CNRS, University Jean Monnet of Saint-Etienne, F-42023 Saint-Etienne, France; (A.S.V.); (F.G.); (S.A.)
| |
Collapse
|
5
|
Schwake DO, Alum A, Abbaszadegan M. Legionella Occurrence beyond Cooling Towers and Premise Plumbing. Microorganisms 2021; 9:microorganisms9122543. [PMID: 34946143 PMCID: PMC8706379 DOI: 10.3390/microorganisms9122543] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 11/27/2021] [Accepted: 12/06/2021] [Indexed: 11/18/2022] Open
Abstract
Legionella is an environmental pathogen that is responsible for respiratory disease and is a common causative agent of water-related outbreaks. Due to their ability to survive in a broad range of environments, transmission of legionellosis is possible from a variety of sources. Unfortunately, a disproportionate amount of research that is devoted to studying the occurrence of Legionella in environmental reservoirs is aimed toward cooling towers and premise plumbing. As confirmed transmission of Legionella has been linked to many other sources, an over-emphasis on the most common sources may be detrimental to increasing understanding of the spread of legionellosis. This review aims to address this issue by cataloguing studies which have examined the occurrence of Legionella in less commonly investigated environments. By summarizing and discussing reports of Legionella in fresh water, ground water, saltwater, and distribution system drinking water, future environmental and public health researchers will have a resource to aid in investigating these pathogens in relevant sources.
Collapse
Affiliation(s)
- David Otto Schwake
- Department of Natural Sciences, Middle Georgia State University, 100 University Pkwy, Macon, GA 31206, USA;
| | - Absar Alum
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA;
| | - Morteza Abbaszadegan
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA;
- Correspondence: ; Tel.: +1-480-965-3868
| |
Collapse
|
6
|
Effects of climate changes and road exposure on the rapidly rising legionellosis incidence rates in the United States. PLoS One 2021; 16:e0250364. [PMID: 33886659 PMCID: PMC8061983 DOI: 10.1371/journal.pone.0250364] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Accepted: 03/30/2021] [Indexed: 11/27/2022] Open
Abstract
Legionellosis is an infection acquired through inhalation of aerosols that are contaminated with environmental bacteria Legionella spp. The bacteria require warm temperature for proliferation in bodies of water and moist soil. The legionellosis incidence in the United States has been rising rapidly in the past two decades without a clear explanation. In the meantime, the US has recorded consecutive years of above-norm temperature since 1997 and precipitation surplus since 2008. The present study analyzed the legionellosis incidence in the US during the 20-year period of 1999 to 2018 and correlated with concurrent temperature, precipitation, solar ultraviolet B (UVB) radiation, and vehicle mileage data. The age-adjusted legionellosis incidence rates rose exponentially from 0.40/100,000 in 1999 (with 1108 cases) to 2.69/100,000 in 2018 (with 9933 cases) at a calculated annual increase of 110%. In regression analyses, the rise correlated with an increase in vehicle miles driven and with temperature and precipitation levels that have been above the 1901–2000 mean since 1997 and 2008, respectively, suggesting more road exposure to traffic-generated aerosols and promotive effects of anomalous climate. Remarkably, the regressions with cumulative anomalies of temperature and precipitation were robust (R2 ≥ 0.9145, P ≤ 4.7E-11), implying possible changes to microbial ecology in the terrestrial and aquatic environments. An interactive synergy between annual precipitation and vehicle miles was also found in multiple regressions. Meanwhile, the bactericidal UVB radiation has been decreasing, which also contributed to the rising incidence in an inverse correlation. The 2018 legionellosis incidence peak corresponded to cumulative effects of the climate anomalies, vast vehicle miles (3,240 billion miles, 15904 km per capita), record high precipitation (880.1 mm), near record low UVB radiation (7488 kJ/m2), and continued above-norm temperature (11.96°C). These effects were examined and demonstrated in California, Florida, New Jersey, Ohio, and Wisconsin, states that represent diverse incidence rates and climates. The incidence and above-norm temperature both rose most in cold Wisconsin. These results suggest that warming temperature and precipitation surplus have likely elevated the density of Legionella bacteria in the environment, and together with road exposure explain the rapidly rising incidence of legionellosis in the United States. These trends are expected to continue, warranting further research and efforts to prevent infection.
Collapse
|
7
|
Short-term associations between Legionnaires' disease incidence and meteorological variables in Belgium, 2011-2019. Epidemiol Infect 2020; 148:e150. [PMID: 32345387 PMCID: PMC7374801 DOI: 10.1017/s0950268820000886] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The number of reported cases with Legionnaires' disease (LD) is increasing in Belgium. Previous studies have investigated the associations between LD incidence and meteorological factors, but the Belgian data remained unexplored. We investigated data collected between 2011 and 2019. Daily exposure data on temperature, relative humidity, precipitation and wind speed was obtained from the Royal Meteorological Institute for 29 weather stations. Case data were collected from the national reference centre and through mandatory notification. Daily case and exposure data were aggregated by province. We conducted a time-stratified case-crossover study. The 'at risk' period was defined as 10 to 2 days prior to disease onset. The corresponding days in the other study years were selected as referents. We fitted separate conditional Poisson models for each day in the 'at risk' period and a distributed lag non-linear model (DLNM) which fitted all data in one model. LD incidence showed a yearly peak in August and September. A total of 614 cases were included. Given seasonality, a sequence of precipitation, followed by high relative humidity and low wind speed showed a statistically significant association with the number of cases 6 to 4 days later. We discussed the advantages of DLNM in this context.
Collapse
|
8
|
Villanueva D, Schepanski K. Investigation of atmospheric conditions fostering the spreading of legionnaires' disease in outbreaks related to cooling towers. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY 2019; 63:1347-1356. [PMID: 31342243 DOI: 10.1007/s00484-019-01751-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 06/26/2019] [Accepted: 06/26/2019] [Indexed: 06/10/2023]
Abstract
Legionnaires' disease (LD) is a severe lung infection caused by the bacteria Legionella pneumophila which is usually associated with water managing installations like cooling towers. Several outbreaks of LD have been linked to individual sources of bioaerosol in the past. However, the transmission pathways as well as the influence of meteorological factors in the spreading of such bioaerosols remain unclear. Using the meteorological data near 12 LD outbreaks in Europe for the period 2000-2016, the correlation between key meteorological factors and the occurrence of LD was assessed. Temperature, humidity, atmospheric pressure, wind speed, precipitation, cloud cover and, for the first time, fog occurrence were included as potential risk factors. It was found that the occurrence of fog was related to four of the LD outbreaks, suggesting that the presence of fog droplets and/or the thermal inversions associated with fog may play a role in the disease spreading. This finding can contribute to outbreak investigations and to the prevention of future outbreaks.
Collapse
Affiliation(s)
- Diego Villanueva
- Leibniz Institute for Tropospheric Research, Permoser Str. 15, 04318, Leipzig, Germany.
| | - Kerstin Schepanski
- Leibniz Institute for Tropospheric Research, Permoser Str. 15, 04318, Leipzig, Germany
| |
Collapse
|
9
|
Prussin AJ, Schwake DO, Marr LC. Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment. BUILDING AND ENVIRONMENT 2017; 123:684-695. [PMID: 29104349 PMCID: PMC5665586 DOI: 10.1016/j.buildenv.2017.06.024] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Legionella is a genus of pathogenic Gram-negative bacteria responsible for a serious disease known as legionellosis, which is transmitted via inhalation of this pathogen in aerosol form. There are two forms of legionellosis: Legionnaires' disease, which causes pneumonia-like symptoms, and Pontiac fever, which causes influenza-like symptoms. Legionella can be aerosolized from various water sources in the built environment including showers, faucets, hot tubs/swimming pools, cooling towers, and fountains. Incidence of the disease is higher in the summertime, possibly because of increased use of cooling towers for air conditioning systems and differences in water chemistry when outdoor temperatures are higher. Although there have been decades of research related to Legionella transmission, many knowledge gaps remain. While conventional wisdom suggests that showering is an important source of exposure in buildings, existing measurements do not provide strong support for this idea. There has been limited research on the potential for Legionella transmission through heating, ventilation, and air conditioning (HVAC) systems. Epidemiological data suggest a large proportion of legionellosis cases go unreported, as most people who are infected do not seek medical attention. Additionally, controlled laboratory studies examining water-to-air transfer and source tracking are still needed. Herein, we discuss ten questions that spotlight current knowledge about Legionella transmission in the built environment, engineering controls that might prevent future disease outbreaks, and future research that is needed to advance understanding of transmission and control of legionellosis.
Collapse
Affiliation(s)
- Aaron J. Prussin
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
- Corresponding Author:
| | - David Otto Schwake
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Linsey C. Marr
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| |
Collapse
|
10
|
Abstract
Legionella pneumophila and influenza types A and B viruses can cause either community-acquired pneumonia with respiratory failure, or Legionella infection could attribute to influenza infection with potentially fatal prognosis. Copathogenesis between pandemic influenza and bacteria is characterized by complex interactions between coinfecting pathogens and the host. Understanding the underlying reason of the emersion of the secondary bacterial infection during an influenza infection is challenging. The dual infection has an impact on viral control and may delay viral clearance. Effective vaccines and antiviral therapy are crucial to increase resistance toward influenza, decrease the prevalence of influenza, and possibly interrupt the potential secondary bacterial infections.
Collapse
Affiliation(s)
- Eleni E Magira
- 1st Department of Critical Care Medicine, Evangelismos General Hospital, National and Kapodistrian University of Athens, 45-47 Ispilandou Street, Athens 10675, Greece.
| | - Sryros Zakynthinos
- 1st Department of Critical Care and Pulmonary Services, Center of Sleep Disorders, Evangelismos General Hospital, National and Kapodistrian University of Athens, 45-47 Ipsilantou Street, Athens 10676, Greece
| |
Collapse
|
11
|
Lesnik R, Brettar I, Höfle MG. Legionella species diversity and dynamics from surface reservoir to tap water: from cold adaptation to thermophily. THE ISME JOURNAL 2016; 10:1064-80. [PMID: 26528838 PMCID: PMC5029207 DOI: 10.1038/ismej.2015.199] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 08/12/2015] [Accepted: 09/22/2015] [Indexed: 12/20/2022]
Abstract
Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8-14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8-40%) accompanied by 5-14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella.
Collapse
Affiliation(s)
- René Lesnik
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research, Braunschweig, Germany
| | - Ingrid Brettar
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research, Braunschweig, Germany
| | - Manfred G Höfle
- Department of Vaccinology and Applied Microbiology, Helmholtz Centre for Infection Research, Braunschweig, Germany
| |
Collapse
|