1
|
Leonetti CT, Lindberg H, Schwake DO, Cotter RL. A Call to Assess the Impacts of Course-Based Undergraduate Research Experiences for Career and Technical Education, Allied Health, and Underrepresented Students at Community Colleges. CBE Life Sci Educ 2023; 22:ar4. [PMID: 36607290 PMCID: PMC10074272 DOI: 10.1187/cbe.21-11-0318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 10/17/2022] [Accepted: 11/03/2022] [Indexed: 06/17/2023]
Abstract
Course-based undergraduate research experiences (CUREs) have the potential to impact student success and reduce barriers for students to participate in undergraduate research. Literature review has revealed that, while CUREs are being implemented at both community colleges (CCs) and bachelor's degree-granting institutions, there are limited published studies on the differential impacts CUREs may have on CC students in allied health programs, career and technical education, and nursing pathways (termed "workforce" in this essay). This essay summarizes proposed outcomes of CURE instruction and explores possible reasons for limited reporting on outcomes for CC and workforce students. It also provides recommendations to guide action and effect change regarding CURE implementation and assessment at CCs. This essay is a call to action to expand the science, technology, engineering, and mathematics career development pathway to include workforce students, implement CUREs designed for workforce students, and assess the differential impacts CUREs may have on workforce student populations at CCs.
Collapse
Affiliation(s)
| | - Heather Lindberg
- Department of Biology, Virginia Western Community College, Roanoke, VA 24015
| | - David Otto Schwake
- Department of Natural Sciences, Middle Georgia State University, Macon, GA 31206
| | - Robin L. Cotter
- Department of Biosciences, Phoenix College, Phoenix, AZ 85013
| |
Collapse
|
2
|
Schwake DO, Sandrin T, Zhang L, Abbaszadegan M. Strain-Level Characterization of Legionella Environmental Isolates via MALDI-TOF-MS. Microorganisms 2022; 11:microorganisms11010008. [PMID: 36677300 PMCID: PMC9863361 DOI: 10.3390/microorganisms11010008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 12/04/2022] [Accepted: 12/15/2022] [Indexed: 12/24/2022] Open
Abstract
As a waterborne pathogen of increasing concern, techniques for cost-effective and rapid characterization of Legionella are vital. This study examines the development of a Matrix Assisted Laser Desorption/Ionization-Time of Flight Mass Spectrometry (MALDI-TOF-MS) analysis methodology for this microbe. First, optimal sample preparation methods for the analysis of environmental Legionella isolates via MALDI-TOF-MS were determined. These methods were then implemented to perform strain-level characterization of environmental Legionella isolates from central Arizona. Results demonstrate that a MALDI-TOF-MS method involving BCYE agar-based culturing and protein extraction-based sample preparation yield high-quality mass spectra. Twenty-eight environmental Legionella isolates originating from two separate drinking water distribution systems were analyzed. Multiple species were detected, and strain-level characterization was achieved, with 12 unique strains distinguished. In addition, isolates of L. pneumophila, the most common species observed in the study, were correctly assigned to specific sampling sites. These results demonstrate the potential for this technique to be applied for sub-species characterization of Legionella with significant benefits over established methodologies.
Collapse
Affiliation(s)
- David Otto Schwake
- Department of Natural Sciences, Middle Georgia State University, 100 University Pkwy, Macon, GA 31206, USA
| | - Todd Sandrin
- School of Mathematical and Natural Sciences, New College of Interdisciplinary Arts & Sciences, Arizona State University at the West Campus, 4701 W. Thunderbird Road, Glendale, AZ 85306, USA
| | - Lin Zhang
- China Innovation Center, Shimadzu (China) Co., Beijing Branch, Beijing 100020, China
| | - Morteza Abbaszadegan
- School of Sustainable Engineering and the Built Environment, Arizona State University at the Tempe Campus, 1151 S. Forest Ave, Tempe, AZ 85281, USA
- Correspondence:
| |
Collapse
|
3
|
Schwake DO, Alum A, Abbaszadegan M. Legionella Occurrence beyond Cooling Towers and Premise Plumbing. Microorganisms 2021; 9:microorganisms9122543. [PMID: 34946143 PMCID: PMC8706379 DOI: 10.3390/microorganisms9122543] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 11/27/2021] [Accepted: 12/06/2021] [Indexed: 11/18/2022] Open
Abstract
Legionella is an environmental pathogen that is responsible for respiratory disease and is a common causative agent of water-related outbreaks. Due to their ability to survive in a broad range of environments, transmission of legionellosis is possible from a variety of sources. Unfortunately, a disproportionate amount of research that is devoted to studying the occurrence of Legionella in environmental reservoirs is aimed toward cooling towers and premise plumbing. As confirmed transmission of Legionella has been linked to many other sources, an over-emphasis on the most common sources may be detrimental to increasing understanding of the spread of legionellosis. This review aims to address this issue by cataloguing studies which have examined the occurrence of Legionella in less commonly investigated environments. By summarizing and discussing reports of Legionella in fresh water, ground water, saltwater, and distribution system drinking water, future environmental and public health researchers will have a resource to aid in investigating these pathogens in relevant sources.
Collapse
Affiliation(s)
- David Otto Schwake
- Department of Natural Sciences, Middle Georgia State University, 100 University Pkwy, Macon, GA 31206, USA;
| | - Absar Alum
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA;
| | - Morteza Abbaszadegan
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA;
- Correspondence: ; Tel.: +1-480-965-3868
| |
Collapse
|
4
|
Garner E, Brown CL, Schwake DO, Rhoads WJ, Arango-Argoty G, Zhang L, Jospin G, Coil DA, Eisen JA, Edwards MA, Pruden A. Comparison of Whole-Genome Sequences of Legionella pneumophila in Tap Water and in Clinical Strains, Flint, Michigan, USA, 2016. Emerg Infect Dis 2020; 25:2013-2020. [PMID: 31625848 PMCID: PMC6810188 DOI: 10.3201/eid2511.181032] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
During the water crisis in Flint, Michigan, USA (2014-2015), 2 outbreaks of Legionnaires' disease occurred in Genesee County, Michigan. We compared whole-genome sequences of 10 clinical Legionella pneumophila isolates submitted to a laboratory in Genesee County during the second outbreak with 103 water isolates collected the following year. We documented a genetically diverse range of L. pneumophila strains across clinical and water isolates. Isolates belonging to 1 clade (3 clinical isolates, 3 water isolates from a Flint hospital, 1 water isolate from a Flint residence, and the reference Paris strain) had a high degree of similarity (2-1,062 single-nucleotide polymorphisms), all L. pneumophila sequence type 1, serogroup 1. Serogroup 6 isolates belonging to sequence type 2518 were widespread in Flint hospital water samples but bore no resemblance to available clinical isolates. L. pneumophila strains in Flint tap water after the outbreaks were diverse and similar to some disease-causing strains.
Collapse
|
5
|
Prussin AJ, Schwake DO, Lin K, Gallagher DL, Buttling L, Marr LC. Survival of the Enveloped Virus Phi6 in Droplets as a Function of Relative Humidity, Absolute Humidity, and Temperature. Appl Environ Microbiol 2018; 84:e00551-18. [PMID: 29625986 PMCID: PMC5981065 DOI: 10.1128/aem.00551-18] [Citation(s) in RCA: 119] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 04/03/2018] [Indexed: 01/30/2023] Open
Abstract
Infectious diseases caused by enveloped viruses, such as influenza, severe acute respiratory syndrome (SARS), and Middle East respiratory syndrome (MERS), cause thousands of deaths and billions of dollars of economic losses per year. Studies have found a relationship among temperature, humidity, and influenza virus incidence, transmission, or survival; however, there are contradictory claims about whether absolute humidity (AH) or relative humidity (RH) is most important in mediating virus infectivity. Using the enveloped bacteriophage Phi6, which has been suggested as a surrogate for influenza viruses and coronaviruses, we designed a study to discern whether AH, RH, or temperature is a better predictor of virus survival in droplets. Our results show that Phi6 survived best at high (>85%) and low (<60%) RHs, with a significant decrease in infectivity at mid-range RHs (∼60 to 85%). At an AH of less than 22 g · m-3, the loss in infectivity was less than 2 orders of magnitude; however, when the AH was greater than 22 g · m-3, the loss in infectivity was typically greater than 6 orders of magnitude. At a fixed RH of 75%, infectivity was very sensitive to temperature, decreasing two orders of magnitude between 19°C and 25°C. We used random forest modeling to identify the best environmental predictors for modulating virus infectivity. The model explained 83% of variation in Phi6 infectivity and suggested that RH is the most important factor in controlling virus infectivity in droplets. This research provides novel information about the complex interplay between temperature, humidity, and the survival of viruses in droplets.IMPORTANCE Enveloped viruses are responsible for a number of infectious diseases resulting in thousands of deaths and billions of dollars of economic losses per year in the United States. There has been a lively debate in the literature over whether absolute humidity (AH) or relative humidity (RH) modulates virus infectivity. We designed a controlled study and used advanced statistical modeling techniques specifically to address this question. By providing an improved understanding of the relationship between environmental conditions and virus infectivity, our work will ultimately lead to improved strategies for predicting and controlling disease transmission.
Collapse
Affiliation(s)
- Aaron J Prussin
- Via Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - David Otto Schwake
- Via Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Kaisen Lin
- Via Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Daniel L Gallagher
- Via Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Lauren Buttling
- Via Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Linsey C Marr
- Via Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| |
Collapse
|
6
|
Rhoads WJ, Garner E, Ji P, Zhu N, Parks J, Schwake DO, Pruden A, Edwards MA. Distribution System Operational Deficiencies Coincide with Reported Legionnaires' Disease Clusters in Flint, Michigan. Environ Sci Technol 2017; 51:11986-11995. [PMID: 28849909 DOI: 10.1021/acs.est.7b01589] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We hypothesize that the increase in reported Legionnaires' disease from June 2014 to November 2015 in Genesee County, MI (where Flint is located) was directly linked to the switch to corrosive Flint River water from noncorrosive Detroit water from April 2014 to October 2015. To address the lack of epidemiological data linking the drinking water supplies to disease incidence, we gathered physiochemical and biological water quality data from 2010 to 2016 to evaluate characteristics of the Flint River water that were potentially conducive to Legionella growth. The treated Flint River water was 8.6 times more corrosive than Detroit water in short-term testing, releasing more iron, which is a key Legionella nutrient, while also directly causing disinfectant to decay more rapidly. The Flint River water source was also 0.8-6.7 °C warmer in summer months than Detroit water and exceeded the minimum Legionella growth temperature of 20 °C more frequently (average number of days per year for Detroit was 63 versus that for the Flint River, which was 157). The corrosive water also led to 1.3-2.2 times more water main breaks in 2014-2015 compared to 2010-2013; such disruptions have been associated with outbreaks in other locales. Importantly, Legionella spp. and Legionella pneumophila decreased after switching back to Detroit water, in terms of both gene markers and culturability, when August and October 2015 were compared to November 2016.
Collapse
Affiliation(s)
- William J Rhoads
- Department of Civil and Environmental Engineering, Virginia Tech , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Emily Garner
- Department of Civil and Environmental Engineering, Virginia Tech , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Pan Ji
- Department of Civil and Environmental Engineering, Virginia Tech , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Ni Zhu
- Department of Civil and Environmental Engineering, Virginia Tech , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Jeffrey Parks
- Department of Civil and Environmental Engineering, Virginia Tech , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - David Otto Schwake
- Department of Civil and Environmental Engineering, Virginia Tech , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Amy Pruden
- Department of Civil and Environmental Engineering, Virginia Tech , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Marc A Edwards
- Department of Civil and Environmental Engineering, Virginia Tech , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| |
Collapse
|
7
|
Prussin AJ, Schwake DO, Marr LC. Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment. Build Environ 2017; 123:684-695. [PMID: 29104349 PMCID: PMC5665586 DOI: 10.1016/j.buildenv.2017.06.024] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Legionella is a genus of pathogenic Gram-negative bacteria responsible for a serious disease known as legionellosis, which is transmitted via inhalation of this pathogen in aerosol form. There are two forms of legionellosis: Legionnaires' disease, which causes pneumonia-like symptoms, and Pontiac fever, which causes influenza-like symptoms. Legionella can be aerosolized from various water sources in the built environment including showers, faucets, hot tubs/swimming pools, cooling towers, and fountains. Incidence of the disease is higher in the summertime, possibly because of increased use of cooling towers for air conditioning systems and differences in water chemistry when outdoor temperatures are higher. Although there have been decades of research related to Legionella transmission, many knowledge gaps remain. While conventional wisdom suggests that showering is an important source of exposure in buildings, existing measurements do not provide strong support for this idea. There has been limited research on the potential for Legionella transmission through heating, ventilation, and air conditioning (HVAC) systems. Epidemiological data suggest a large proportion of legionellosis cases go unreported, as most people who are infected do not seek medical attention. Additionally, controlled laboratory studies examining water-to-air transfer and source tracking are still needed. Herein, we discuss ten questions that spotlight current knowledge about Legionella transmission in the built environment, engineering controls that might prevent future disease outbreaks, and future research that is needed to advance understanding of transmission and control of legionellosis.
Collapse
Affiliation(s)
- Aaron J. Prussin
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
- Corresponding Author:
| | - David Otto Schwake
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Linsey C. Marr
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| |
Collapse
|
8
|
Schwake DO, Alum A, Abbaszadegan M. Automobile windshield washer fluid: A potential source of transmission for Legionella. Sci Total Environ 2015; 526:271-277. [PMID: 25955695 DOI: 10.1016/j.scitotenv.2015.03.122] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2015] [Revised: 03/27/2015] [Accepted: 03/28/2015] [Indexed: 06/04/2023]
Abstract
Epidemiological evidence suggesting driving cars to be a risk factor for legionellosis has prompted public health studies to investigate vehicle windshield washer fluid as a novel transmission source of this disease. The goal of the current study was to investigate whether or not windshield washer fluid could serve as a potential source of transmission for Legionella. A wide variation in the survival of L. pneumophila was observed when incubated in different washer fluids at 25 and 37 °C, however, one brand tested supported Legionella survival similar to or greater than sterilized deionized water. In addition, 1 L of tap water contained in a washer fluid reservoir was able to support population growth and survival of Legionella for several months. In a field study examining the windshield washer fluid of 12 elementary school buses, Legionella were detected from 84% of samples at a high concentration of 8.1×10(4) CFU/mL. Culturable cells were also detected in aerosolized washer fluid during washer fluid spray. By demonstrating survival in certain windshield washer fluids, growth within washer fluid reservoirs, and the presence of viable cells in bus washer fluid spray, we have provided evidence suggesting the potential for a novel route of Legionella exposure.
Collapse
Affiliation(s)
- David Otto Schwake
- School of Life Sciences, Arizona State University, P.O. Box 875306, Tempe, AZ 85287, USA
| | - Absar Alum
- School of Sustainable Engineering and the Built Environment, Arizona State University, P.O. Box 875306, Tempe, AZ 85287, USA
| | - Morteza Abbaszadegan
- School of Sustainable Engineering and the Built Environment, Arizona State University, P.O. Box 875306, Tempe, AZ 85287, USA.
| |
Collapse
|