1
|
Liu G, Guo H, Zhao W, Yan H, Zhang E, Gao L. Advancements in Preprocessing and Analysis of Nitrite and Nitrate since 2010 in Biological Samples: A Review. Molecules 2023; 28:7122. [PMID: 37894601 PMCID: PMC10609401 DOI: 10.3390/molecules28207122] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/10/2023] [Accepted: 10/12/2023] [Indexed: 10/29/2023] Open
Abstract
As a substance present in organisms, nitrite is a metabolite of nitric oxide and can also be ingested. Nitrate is the metabolite of nitrite. Therefore, it is necessary to measure it quickly, easily and accurately to evaluate the health status of humans. Although there have been several reviews on analytical methods for non-biological samples, there have been no reviews focused on both sample preparation and analytical methods for biological samples. First, rapid and accurate nitrite measurement has significant effects on human health. Second, the detection of nitrite in biological samples is problematic due to its very low concentration and matrix interferences. Therefore, the pretreatment plus measuring methods for nitrite and nitrate obtained from biological samples since 2010 are summarized in the present review, and their prospects for the future are proposed. The treatment methods include liquid-liquid microextraction, various derivatization reactions, liquid-liquid extraction, protein precipitation, solid phase extraction, and cloud point extraction. Analytical methods include spectroscopic methods, paper-based analytical devices, ion chromatography, liquid chromatography, gas chromatography-mass spectrometry, electrochemical methods, liquid chromatography-mass spectrometry and capillary electrophoresis. Derivatization reagents with rapid quantitative reactions and advanced extraction methods with high enrichment efficiency are also included. Nitrate and nitrate should be determined at the same time by the same analytical method. In addition, much exploration has been performed on formulating fast testing through microfluidic technology. In this review, the newest developments in nitrite and nitrate processing are a focus in addition to novel techniques employed in such analyses.
Collapse
Affiliation(s)
- Guojie Liu
- Department of Chemistry, School of Forensic Medicine, China Medical University, Shenyang 110122, China;
- Liaoning Province Key Laboratory of Forensic Bio-Evidence Sciences, Shenyang 110122, China
- Center of Forensic Investigation, China Medical University, Shenyang 110122, China
| | - Honghui Guo
- Liaoning Province Key Laboratory of Forensic Bio-Evidence Sciences, Shenyang 110122, China
- Center of Forensic Investigation, China Medical University, Shenyang 110122, China
- Forensic Analytical Toxicology Department, School of Forensic Medicine, China Medical University, Shenyang 110122, China
| | - Wanlin Zhao
- Liaoning Province Key Laboratory of Forensic Bio-Evidence Sciences, Shenyang 110122, China
- Center of Forensic Investigation, China Medical University, Shenyang 110122, China
- Forensic Analytical Toxicology Department, School of Forensic Medicine, China Medical University, Shenyang 110122, China
| | - Hongmu Yan
- Liaoning Province Key Laboratory of Forensic Bio-Evidence Sciences, Shenyang 110122, China
- Center of Forensic Investigation, China Medical University, Shenyang 110122, China
- Forensic Analytical Toxicology Department, School of Forensic Medicine, China Medical University, Shenyang 110122, China
| | - Enze Zhang
- First Clinical College, China Medical University, Shenyang 110122, China
| | - Lina Gao
- Liaoning Province Key Laboratory of Forensic Bio-Evidence Sciences, Shenyang 110122, China
- Center of Forensic Investigation, China Medical University, Shenyang 110122, China
- Forensic Analytical Toxicology Department, School of Forensic Medicine, China Medical University, Shenyang 110122, China
| |
Collapse
|
2
|
A new ultrasound-assisted liquid-liquid microextraction method utilizing a switchable hydrophilicity solvent for spectrophotometric determination of nitrite in food samples. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2023.105267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
|
3
|
Al-Hashimi NN, Al-Degs YS, Jaafreh S, Al-Khatib HS, El-Sheikh AH, Abdelghani JI, Jaber MR. Simultaneous determination of furosemide and carbamazepine in biological matrices by solvent bar microextraction combined with HPLC-DAD and central composite design CCD. Biomed Chromatogr 2022; 36:e5476. [PMID: 35918842 DOI: 10.1002/bmc.5476] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 07/25/2022] [Accepted: 07/27/2022] [Indexed: 11/06/2022]
Abstract
A sensitive and simple sample pretreatment method based on a two-phase solvent bar microextraction SBME technique coupled with HPLC-DAD was developed for simultaneous extraction and determination of trace amounts of furosemide and carbamazepine in human urine and plasma samples. The significance of operational factors on carbamazepine and furosemide extraction efficiency % (EE%) was screened using full factorial design (FFD) while central composite design (CCD) was used to model the entire process. A quadratic model was found convenient to correlate the extraction EE% of selected drugs with dominant experimental factors. A Pareto chart was also used to examine the importance of factors on drugs' EE%. The analytical performance of the method in urine and plasma samples demonstrated good linearity R2 ˃ 0.992 with detection limits ranging from 4.2 to 10.9 μg L-1 , and extraction recovery ˃ 89.45% for both drugs in urine and plasma samples. A comparison against published methods was also studied and the results revealed that the developed method exhibits a confident sensitivity, feasible operation, and simple analysis for both drugs. Finally, the practicability of the validated SBME-HPLC-DAD method was demonstrated by successfully applying it to the analysis of furosemide, and carbamazepine in real patient urine samples.
Collapse
Affiliation(s)
- Nabil N Al-Hashimi
- The Hashemite University, Faculty of Pharmaceutical Sciences, Department of Pharmaceutical Chemistry, Al-Zarqa, Jordan
| | - Yahya S Al-Degs
- The Hashemite University, Faculty of Science, Department of Chemistry, Al-Zarqa, Jordan
| | - Sawsan Jaafreh
- The Hashemite University, Faculty of Science, Department of Chemistry, Al-Zarqa, Jordan
| | - Hatim S Al-Khatib
- The University of Jordan, Faculty of Pharmacy, Department of Pharmaceutics and Pharmaceutical Technology, Amman, Jordan
| | - Amjad H El-Sheikh
- The Hashemite University, Faculty of Science, Department of Chemistry, Al-Zarqa, Jordan
| | - Jafar I Abdelghani
- The Hashemite University, Faculty of Science, Department of Chemistry, Al-Zarqa, Jordan
| | - Mai R Jaber
- The Hashemite University, Faculty of Pharmaceutical Sciences, Department of Pharmaceutics and Pharmaceutical Technology, Al-Zarqa, Jordan
| |
Collapse
|
4
|
A Simple and Rapid Spectrophotometric Method for Nitrite Detection in Small Sample Volumes. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9070161] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
A simple, rapid, and environmentally-friendly spectrophotometric method for nitrite detection was developed. Detection was based on a redox reaction with iodide ions in an acidic condition. The reaction was evaluated by detecting the increase in absorbance of the colored product of iodine at 362 nm wavelength. To obtain a good spectrophotometric performance, the iodide ions concentration, hydrochloric acid concentration, and reaction time were optimized. In the optimal condition, the developed spectrophotometric method provided a linear range of 0.0625 to 4.00 mg L−1 (r = 0.9985), reaction time for 10 min, a limit of detection of 25 µg L−1, and a limit of quantitation of 85 µg L−1. This method showed good repeatability (RSD < 9.21%), high sample throughput (9 samples min−1), and good accuracy (recovery = 88 ± 2 to 99.5 ± 0.4%). The method has the potential to be used in crime scene investigations as a rapid screening test for gunshot residue detection via nitrite detection.
Collapse
|
5
|
Refai HM, Sebaei AS. Daily intake of nitrate and nitrite via meat and poultry in Egypt. FOOD ADDITIVES & CONTAMINANTS PART B-SURVEILLANCE 2020; 13:292-297. [PMID: 32623962 DOI: 10.1080/19393210.2020.1785553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Nitrate and nitrite are the most applied food additives to inhibit microbial growth. The main risk of nitrate and nitrite presence in food is the formation of nitrosamines during food preparation and digestion. However, dietary intake of nitrite and nitrate from food has potential cardiovascular benefits. Accordingly, 160 samples from meat and poultry were randomly collected to evaluate the level of occurrence nitrate and nitrite using an HPLC method and estimate the daily intake (EDI) of Egyptian adults and children. The levels of nitrate and nitrite ranged between 1.3-557 mg/kg and 6-812 mg/kg, respectively. The EDI was compared with the accepted daily intake (ADI) represented in the hazard index (HI) scale. The nitrite results clarify that all HI values were above 1 for all commodities, while for nitrate it exceeded 1 only for canned meat and basturma, when consumed by children.
Collapse
Affiliation(s)
- Hoda M Refai
- Agricultural Research Center, Central Laboratory of Residue Analysis of Pesticides and Heavy Metals in Food, Ministry of Agriculture , Giza, Egypt
| | - Ahmed Salem Sebaei
- Agricultural Research Center, Central Laboratory of Residue Analysis of Pesticides and Heavy Metals in Food, Ministry of Agriculture , Giza, Egypt
| |
Collapse
|
6
|
Fashi A, Cheraghi M, Badiee H, Zamani A. An analytical strategy based on the combination of ultrasound assisted flat membrane liquid phase microextraction and a smartphone reader for trace determination of malondialdehyde. Talanta 2020; 209:120618. [DOI: 10.1016/j.talanta.2019.120618] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 12/02/2019] [Accepted: 12/03/2019] [Indexed: 12/12/2022]
|
7
|
Badiee H, Zanjanchi MA, Zamani A, Fashi A. Hollow fiber liquid-phase microextraction based on the use of a rotating extraction cell: A green approach for trace determination of rhodamine 6G and methylene blue dyes. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2019; 255:113287. [PMID: 31600705 DOI: 10.1016/j.envpol.2019.113287] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 09/08/2019] [Accepted: 09/19/2019] [Indexed: 06/10/2023]
Abstract
In this work, a novel mode of hollow fiber liquid-phase microextraction (HF-LPME) technique namely rotating extraction cell solvent bar microextraction (REC-SBME) was introduced. The proposed method was applied for the preconcentration of methylene blue (MB) and rhodamine 6G (RG) in some real samples, including soft drink, lipstick, environmental water, and wastewater samples. In the extraction setup, two pieces of hollow fibers were fixed on a mechanical support and immersed in a rotating extraction cell containing the sample solution during the extraction process. The rotation of the extraction cell by using an electric motor led to an enhancement in the mass transfer of the dyes from the sample solution into the organic acceptor phase. In the developed procedure, the UV-Vis spectrophotometry and HPLC-UV/Vis were employed as detection methods for the analysis of the acceptor phase and the obtained results were compared. Optimization of the extraction factors affecting the method, including organic solvent type, sample solution pH, extraction time, rotational rate, the volume of sample and acceptor solutions, salt addition, and temperature was performed in order to obtain the best preconcentration factor. Linear dynamic range obtained by HPLC-UV/Vis and spectrophotometry was observed in the ranges of 2.5-1200 ng mL-1 for RG and 1.6-600 ng mL-1 for MB with R2 more than 0.9971. Also, relative standard deviation (RSD) values (n = 3) less than 3.8% were obtained. The good conformity of the obtained results makes UV-Vis spectrophotometric method an ideal tool for routine analysis of trace dyes in the complex matrices after REC-SBME.
Collapse
Affiliation(s)
- Hamid Badiee
- Department of Chemistry, Faculty of Science, University of Guilan, University Campus 2, Rasht, Iran; Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Postal Code 45371-38791, Zanjan, Iran
| | - Mohammad Ali Zanjanchi
- Department of Chemistry, Faculty of Science, University of Guilan, University Campus 2, Rasht, Iran; Department of Chemistry, Faculty of Science, University of Guilan, Rasht, 41335-1914, Iran
| | - Abbasali Zamani
- Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Postal Code 45371-38791, Zanjan, Iran.
| | - Armin Fashi
- Environmental Science Research Laboratory, Department of Environmental Science, Faculty of Science, University of Zanjan, Postal Code 45371-38791, Zanjan, Iran
| |
Collapse
|