van der Waal J, Meijborg V, Coronel R, Dubois R, Oostendorp T. Basis and applicability of noninvasive inverse electrocardiography: a comparison between cardiac source models. Front Physiol 2023; 14:1295103. [PMID: 38152249 PMCID: PMC10752226 DOI: 10.3389/fphys.2023.1295103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 11/30/2023] [Indexed: 12/29/2023] Open
Abstract
The body surface electrocardiogram (ECG) is a direct result of electrical activity generated by the myocardium. Using the body surface ECGs to reconstruct cardiac electrical activity is called the inverse problem of electrocardiography. The method to solve the inverse problem depends on the chosen cardiac source model to describe cardiac electrical activity. In this paper, we describe the theoretical basis of two inverse methods based on the most commonly used cardiac source models: the epicardial potential model and the equivalent dipole layer model. We discuss similarities and differences in applicability, strengths and weaknesses and sketch a road towards improved inverse solutions by targeted use, sequential application or a combination of the two methods.
Collapse
Affiliation(s)
- Jeanne van der Waal
- Department of Clinical and Experimental Cardiology, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Veronique Meijborg
- Department of Clinical and Experimental Cardiology, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Ruben Coronel
- Department of Clinical and Experimental Cardiology, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | - Rémi Dubois
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac, France
| | - Thom Oostendorp
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Centre, Nijmegen, Netherlands
| |
Collapse
|
2
|
Yadan Z, Jian L, Jian W, Yifu L, Haiying L, Hairui L. An expert review of the inverse problem in electrocardiographic imaging for the non-invasive identification of atrial fibrillation drivers. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 240:107676. [PMID: 37343376 DOI: 10.1016/j.cmpb.2023.107676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 06/06/2023] [Accepted: 06/09/2023] [Indexed: 06/23/2023]
Abstract
BACKGROUND AND OBJECTIVE Electrocardiographic imaging (ECGI) has emerged as a non-invasive approach to identify atrial fibrillation (AF) driver sources. This paper aims to collect and review the current research literature on the ECGI inverse problem, summarize the research progress, and propose potential research directions for the future. METHODS AND RESULTS The effectiveness and feasibility of using ECGI to map AF driver sources may be influenced by several factors, such as inaccuracies in the atrial model due to heart movement or deformation, noise interference in high-density body surface potential (BSP), inconvenient and time-consuming BSP acquisition, errors in solving the inverse problem, and incomplete interpretation of the AF driving source information derived from the reconstructed epicardial potential. We review the current research progress on these factors and discuss possible improvement directions. Additionally, we highlight the limitations of ECGI itself, including the lack of a gold standard to validate the accuracy of ECGI technology in locating AF drivers and the challenges associated with guiding AF ablation based on post-processed epicardial potentials due to the intrinsic difference between epicardial and endocardial potentials. CONCLUSIONS Before performing ablation, ECGI can provide operators with predictive information about the underlying locations of AF driver by non-invasively and globally mapping the biatrial electrical activity. In the future, endocardial catheter mapping technology may benefit from the use of ECGI to enhance the diagnosis and ablation of AF.
Collapse
Affiliation(s)
- Zhang Yadan
- Institute of Biomedical Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China
| | - Liang Jian
- Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Guangdong, China
| | - Wu Jian
- Institute of Biomedical Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China.
| | - Li Yifu
- Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Guangdong, China
| | - Li Haiying
- The University of Hong Kong-Shenzhen Hospital, Shenzhen, Guangdong, China
| | - Li Hairui
- The University of Hong Kong-Shenzhen Hospital, Shenzhen, Guangdong, China
| |
Collapse
|
3
|
Sedova KA, van Dam PM, Blahova M, Necasova L, Kautzner J. Localization of the ventricular pacing site from BSPM and standard 12-lead ECG: a comparison study. Sci Rep 2023; 13:9618. [PMID: 37316547 DOI: 10.1038/s41598-023-36768-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Accepted: 06/09/2023] [Indexed: 06/16/2023] Open
Abstract
Inverse ECG imaging methods typically require 32-250 leads to create body surface potential maps (BSPM), limiting their routine clinical use. This study evaluated the accuracy of PaceView inverse ECG method to localize the left or right ventricular (LV and RV, respectively) pacing leads using either a 99-lead BSPM or the 12-lead ECG. A 99-lead BSPM was recorded in patients with cardiac resynchronization therapy (CRT) during sinus rhythm and sequential LV/RV pacing. The non-contrast CT was performed to localize precisely both ECG electrodes and CRT leads. From a BSPM, nine signals were selected to obtain the 12-lead ECG. Both BSPM and 12-lead ECG were used to localize the RV and LV lead, and the localization error was calculated. Consecutive patients with dilated cardiomyopathy, previously implanted with a CRT device, were enrolled (n = 19). The localization error for the RV/LV lead was 9.0 [IQR 4.8-13.6] / 7.7 [IQR 0.0-10.3] mm using the 12-lead ECG and 9.1 [IQR 5.4-15.7] / 9.8 [IQR 8.6-13.1] mm for the BSPM. Thus, the noninvasive lead localization using the 12-lead ECG was accurate enough and comparable to 99-lead BSPM, potentially increasing the capability of 12-lead ECG for the optimization of the LV/RV pacing sites during CRT implant or for the most favorable programming.
Collapse
Affiliation(s)
- Ksenia A Sedova
- Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Sitna Sq. 3105, 27201, Kladno, Czech Republic.
| | - Peter M van Dam
- Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Marie Blahova
- Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Lucie Necasova
- Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Josef Kautzner
- Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| |
Collapse
|
4
|
Melgaard J, van Dam PM, Sommer A, Fruelund P, Nielsen JC, Riahi S, Graff C. Non-invasive estimation of QLV from the standard 12-lead ECG in patients with left bundle branch block. Front Physiol 2022; 13:939240. [PMID: 36213226 PMCID: PMC9532835 DOI: 10.3389/fphys.2022.939240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Accepted: 08/29/2022] [Indexed: 11/13/2022] Open
Abstract
Background: Cardiac resynchronization therapy (CRT) is a treatment for patients with heart failure and electrical dyssynchrony, i.e., left bundle branch block (LBBB) ECG pattern. CRT resynchronizes ventricular contraction with a right ventricle (RV) and a left ventricle (LV) pacemaker lead. Positioning the LV lead in the latest electrically activated region (measured from Q wave onset in the ECG to LV sensing by the left pacemaker electrode [QLV]) is associated with favorable outcome. However, optimal LV lead placement is limited by coronary venous anatomy and the inability to measure QLV non-invasively before implantation. We propose a novel non-invasive method for estimating QLV in sinus-rhythm from the standard 12-lead ECG.Methods: We obtained 12-lead ECG, LV electrograms and LV lead position in a standard LV 17-segment model from procedural recordings from 135 standard CRT recipients. QLV duration was measured post-operatively. Using a generic heart geometry and corresponding forward model for ECG computation, the electrical activation pattern of the heart was fitted to best match the 12-lead ECG in an iterative optimization procedure. This procedure initialized six activation sites associated with the His-Purkinje system. The initial timing of each site was based on the directions of the vectorcardiogram (VCG). Timing and position of the sites were then changed iteratively to improve the match between simulated and measured ECG. Noninvasive estimation of QLV was done by calculating the time difference between Q-onset on the computed ECG and the activation time corresponding to centroidal epicardial activation time of the segment where the LV electrode is positioned. The estimated QLV was compared to the measured QLV. Further, the distance between the actual LV position and the estimated LV position was computed from the generic ventricular model.Results: On average there was no difference between QLV measured from procedural recordings and non-invasive estimation of QLV (ΔQLV=−3.0±22.5 ms, p=0.12). Median distance between actual LV pacing site and the estimated pacing site was 18.6 mm (IQR 17.3 mm).Conclusion: Using the standard 12-lead ECG and a generic heart model it is possible to accurately estimate QLV. This method may potentially be used to support patient selection, optimize implant procedures, and to simulate optimal stimulation parameters prior to pacemaker implantation.
Collapse
Affiliation(s)
- Jacob Melgaard
- CardioTech Research Group, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Aalborg, Denmark
- *Correspondence: Jacob Melgaard,
| | - Peter M. van Dam
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Netherlands
- Peacs BV, Nieuwerbrug Aan Den Rijn, Netherlands
| | - Anders Sommer
- Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark
| | - Patricia Fruelund
- Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark
| | | | - Sam Riahi
- Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark
| | - Claus Graff
- CardioTech Research Group, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Aalborg, Denmark
| |
Collapse
|
5
|
Modeling the His-Purkinje Effect in Non-invasive Estimation of Endocardial and Epicardial Ventricular Activation. Ann Biomed Eng 2022; 50:343-359. [PMID: 35072885 PMCID: PMC8847268 DOI: 10.1007/s10439-022-02905-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 01/01/2022] [Indexed: 01/10/2023]
Abstract
Inverse electrocardiography (iECG) estimates epi- and endocardial electrical activity from body surface potentials maps (BSPM). In individuals at risk for cardiomyopathy, non-invasive estimation of normal ventricular activation may provide valuable information to aid risk stratification to prevent sudden cardiac death. However, multiple simultaneous activation wavefronts initiated by the His-Purkinje system, severely complicate iECG. To improve the estimation of normal ventricular activation, the iECG method should accurately mimic the effect of the His-Purkinje system, which is not taken into account in the previously published multi-focal iECG. Therefore, we introduce the novel multi-wave iECG method and report on its performance. Multi-wave iECG and multi-focal iECG were tested in four patients undergoing invasive electro-anatomical mapping during normal ventricular activation. In each subject, 67-electrode BSPM were recorded and used as input for both iECG methods. The iECG and invasive local activation timing (LAT) maps were compared. Median epicardial inter-map correlation coefficient (CC) between invasive LAT maps and estimated multi-wave iECG versus multi-focal iECG was 0.61 versus 0.31. Endocardial inter-map CC was 0.54 respectively 0.22. Modeling the His-Purkinje system resulted in a physiologically realistic and robust non-invasive estimation of normal ventricular activation, which might enable the early detection of cardiac disease during normal sinus rhythm.
Collapse
|
6
|
Schuler S, Schaufelberger M, Bear LR, Bergquist JA, Cluitmans MJM, Coll-Font J, Onak ON, Zenger B, Loewe A, MacLeod RS, Brooks DH, Dossel O. Reducing Line-of-block Artifacts in Cardiac Activation Maps Estimated Using ECG Imaging: A Comparison of Source Models and Estimation Methods. IEEE Trans Biomed Eng 2021; 69:2041-2052. [PMID: 34905487 DOI: 10.1109/tbme.2021.3135154] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE To investigate cardiac activation maps estimated using electrocardiographic imaging and to find methods reducing line-of-block (LoB) artifacts, while preserving real LoBs. METHODS Body surface potentials were computed for 137 simulated ventricular excitations. Subsequently, the inverse problem was solved to obtain extracellular potentials (EP) and transmembrane voltages (TMV). From these, activation times (AT) were estimated using four methods and compared to the ground truth. This process was evaluated with two cardiac mesh resolutions. Factors contributing to LoB artifacts were identified by analyzing the impact of spatial and temporal smoothing on the morphology of source signals. RESULTS AT estimation using a spatiotemporal derivative performed better than using a temporal derivative. Compared to deflection-based AT estimation, correlation-based methods were less prone to LoB artifacts but performed worse in identifying real LoBs. Temporal smoothing could eliminate artifacts for TMVs but not for EPs, which could be linked to their temporal morphology. TMVs led to more accurate ATs on the septum than EPs. Mesh resolution had a negligible effect on inverse reconstructions, but small distances were important for cross-correlation-based estimation of AT delays. CONCLUSION LoB artifacts are mainly caused by the inherent spatial smoothing effect of the inverse reconstruction. Among the configurations evaluated, only deflection-based AT estimation in combination with TMVs and strong temporal smoothing can prevent LoB artifacts, while preserving real LoBs. SIGNIFICANCE Regions of slow conduction are of considerable clinical interest and LoB artifacts observed in non-invasive ATs can lead to misinterpretations. We addressed this problem by identifying factors causing such artifacts and methods to reduce them.
Collapse
|
7
|
van der Waal JG, Meijborg VMF, Belterman CNW, Streekstra GJ, Oostendorp TF, Coronel R. Ex vivo Validation of Noninvasive Epicardial and Endocardial Repolarization Mapping. Front Physiol 2021; 12:737609. [PMID: 34744778 PMCID: PMC8569864 DOI: 10.3389/fphys.2021.737609] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 09/21/2021] [Indexed: 11/17/2022] Open
Abstract
Background: The detection and localization of electrophysiological substrates currently involve invasive cardiac mapping. Electrocardiographic imaging (ECGI) using the equivalent dipole layer (EDL) method allows the noninvasive estimation of endocardial and epicardial activation and repolarization times (AT and RT), but the RT validation is limited to in silico studies. We aimed to assess the temporal and spatial accuracy of the EDL method in reconstructing the RTs from the surface ECG under physiological circumstances and situations with artificially induced increased repolarization heterogeneity. Methods: In four Langendorff-perfused pig hearts, we simultaneously recorded unipolar electrograms from plunge needles and pseudo-ECGs from a volume-conducting container equipped with 61 electrodes. The RTs were computed from the ECGs during atrial and ventricular pacing and compared with those measured from the local unipolar electrograms. Regional RT prolongation (cooling) or shortening (pinacidil) was achieved by selective perfusion of the left anterior descending artery (LAD) region. Results: The differences between the computed and measured RTs were 19.0 ± 17.8 and 18.6 ± 13.7 ms for atrial and ventricular paced beats, respectively. The region of artificially delayed or shortened repolarization was correctly identified, with minimum/maximum RT roughly in the center of the region in three hearts. In one heart, the reconstructed region was shifted by ~2.5 cm. The total absolute difference between the measured and calculated RTs for all analyzed patterns in selectively perfused hearts (n = 5) was 39.6 ± 27.1 ms. Conclusion: The noninvasive ECG repolarization imaging using the EDL method of atrial and ventricular paced beats allows adequate quantitative reconstruction of regions of altered repolarization.
Collapse
Affiliation(s)
- Jeanne G van der Waal
- Department of Experimental and Clinical Cardiology, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, Netherlands
| | - Veronique M F Meijborg
- Department of Experimental and Clinical Cardiology, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, Netherlands
| | - Charly N W Belterman
- Department of Experimental and Clinical Cardiology, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, Netherlands
| | - Geert J Streekstra
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, Netherlands
| | - Thom F Oostendorp
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Centre, Nijmegen, Netherlands
| | - Ruben Coronel
- Department of Experimental and Clinical Cardiology, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, Netherlands.,IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France
| |
Collapse
|
8
|
Grandits T, Gillette K, Neic A, Bayer J, Vigmond E, Pock T, Plank G. An Inverse Eikonal Method for Identifying Ventricular Activation Sequences from Epicardial Activation Maps. JOURNAL OF COMPUTATIONAL PHYSICS 2020; 419:109700. [PMID: 32952215 PMCID: PMC7116090 DOI: 10.1016/j.jcp.2020.109700] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
A key mechanism controlling cardiac function is the electrical activation sequence of the heart's main pumping chambers termed the ventricles. As such, personalization of the ventricular activation sequences is of pivotal importance for the clinical utility of computational models of cardiac electrophysiology. However, a direct observation of the activation sequence throughout the ventricular volume is virtually impossible. In this study, we report on a novel method for identification of activation sequences from activation maps measured at the outer surface of the heart termed the epicardium. Conceptually, the method attempts to identify the key factors governing the ventricular activation sequence - the timing of earliest activation sites (EAS) and the velocity tensor field within the ventricular walls - from sparse and noisy activation maps sampled from the epicardial surface and fits an Eikonal model to the observations. Regularization methods are first investigated to overcome the severe ill-posedness of the inverse problem in a simplified 2D example. These methods are then employed in an anatomically accurate biventricular model with two realistic activation models of varying complexity - a simplified trifascicular model (3F) and a topologically realistic model of the His-Purkinje system (HPS). Using epicardial activation maps at full resolution, we first demonstrate that reconstructing the volumetric activation sequence is, in principle, feasible under the assumption of known location of EAS and later evaluate robustness of the method against noise and reduced spatial resolution of observations. Our results suggest that the FIMIN algorithm is able to robustly recover the full 3D activation sequence using epicardial activation maps at a spatial resolution achievable with current mapping systems and in the presence of noise. Comparing the accuracy achieved in the reconstructed activation maps with clinical data uncertainties suggests that the FIMIN method may be suitable for the patient- specific parameterization of activation models.
Collapse
Affiliation(s)
- Thomas Grandits
- Institute of Computer Graphics and Vision, Graz University of Technology
- BioTechMed-Graz, Austria
| | - Karli Gillette
- Institute of Biophysics, Medical University of Graz
- BioTechMed-Graz, Austria
| | - Aurel Neic
- Institute of Biophysics, Medical University of Graz
| | - Jason Bayer
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, Pessac-Bordeaux
| | - Edward Vigmond
- IHU Liryc, Electrophysiology and Heart Modeling Institute, fondation Bordeaux Université, Pessac-Bordeaux
| | - Thomas Pock
- Institute of Computer Graphics and Vision, Graz University of Technology
- BioTechMed-Graz, Austria
| | - Gernot Plank
- Institute of Biophysics, Medical University of Graz
- BioTechMed-Graz, Austria
| |
Collapse
|
9
|
van der Waal J, Meijborg V, Schuler S, Coronel R, Oostendorp T. In silico validation of electrocardiographic imaging to reconstruct the endocardial and epicardial repolarization pattern using the equivalent dipole layer source model. Med Biol Eng Comput 2020; 58:1739-1749. [PMID: 32474796 PMCID: PMC7340677 DOI: 10.1007/s11517-020-02203-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Accepted: 05/22/2020] [Indexed: 02/07/2023]
Abstract
The solution of the inverse problem of electrocardiology allows the reconstruction of the spatial distribution of the electrical activity of the heart from the body surface electrocardiogram (electrocardiographic imaging, ECGI). ECGI using the equivalent dipole layer (EDL) model has shown to be accurate for cardiac activation times. However, validation of this method to determine repolarization times is lacking. In the present study, we determined the accuracy of the EDL model in reconstructing cardiac repolarization times, and assessed the robustness of the method under less ideal conditions (addition of noise and errors in tissue conductivity). A monodomain model was used to determine the transmembrane potentials in three different excitation-repolarization patterns (sinus beat and ventricular ectopic beats) as the gold standard. These were used to calculate the body surface ECGs using a finite element model. The resulting body surface electrograms (ECGs) were used as input for the EDL-based inverse reconstruction of repolarization times. The reconstructed repolarization times correlated well (COR > 0.85) with the gold standard, with almost no decrease in correlation after adding errors in tissue conductivity of the model or noise to the body surface ECG. Therefore, ECGI using the EDL model allows adequate reconstruction of cardiac repolarization times. Graphical abstract Validation of electrocardiographic imaging for repolarization using forward calculated body surface ECGs from simulated activation-repolarization sequences.
Collapse
Affiliation(s)
- Jeanne van der Waal
- Department of Clinical and Experimental Cardiology, Amsterdam University Medical Centers, Meibergdreef 9, 1105, AZ, Amsterdam, The Netherlands.
| | - Veronique Meijborg
- Department of Clinical and Experimental Cardiology, Amsterdam University Medical Centers, Meibergdreef 9, 1105, AZ, Amsterdam, The Netherlands
| | - Steffen Schuler
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Fritz-Haber-Weg 1, 76131, Karlsruhe, Germany
| | - Ruben Coronel
- Department of Clinical and Experimental Cardiology, Amsterdam University Medical Centers, Meibergdreef 9, 1105, AZ, Amsterdam, The Netherlands
| | - Thom Oostendorp
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Centre, Kapittelweg 29, 6525, Nijmegen, The Netherlands
| |
Collapse
|
10
|
Biasi N, Tognetti A. Modelling whole heart electrical activity for ischemia and cardiac pacing simulation. HEALTH AND TECHNOLOGY 2020. [DOI: 10.1007/s12553-020-00417-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
11
|
Kunisch K, Neic A, Plank G, Trautmann P. Inverse localization of earliest cardiac activation sites from activation maps based on the viscous Eikonal equation. J Math Biol 2019; 79:2033-2068. [PMID: 31473798 PMCID: PMC6858910 DOI: 10.1007/s00285-019-01419-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 05/30/2019] [Indexed: 01/25/2023]
Abstract
In this study we propose a novel method for identifying the locations of earliest activation in the human left ventricle from activation maps measured at the epicardial surface. Electrical activation is modeled based on the viscous Eikonal equation. The sites of earliest activation are identified by solving a minimization problem. Arbitrary initial locations are assumed, which are then modified based on a shape derivative based perturbation field until a minimal mismatch between the computed and the given activation maps on the epicardial surface is achieved. The proposed method is tested in two numerical benchmarks, a generic 2D unit-square benchmark, and an anatomically accurate MRI-derived 3D human left ventricle benchmark to demonstrate potential utility in a clinical context. For unperturbed input data, our localization method is able to accurately reconstruct the earliest activation sites in both benchmarks with deviations of only a fraction of the used spatial discretization size. Further, with the quality of the input data reduced by spatial undersampling and addition of noise, we demonstrate that an accurate identification of the sites of earliest activation is still feasible.
Collapse
Affiliation(s)
| | - Aurel Neic
- , Auenbruggerplatz 2, 8036, Graz, Austria
| | | | | |
Collapse
|
12
|
Potyagaylo D, Chmelevsky M, van Dam P, Budanova M, Zubarev S, Treshkur T, Lebedev D. ECG Adapted Fastest Route Algorithm to Localize the Ectopic Excitation Origin in CRT Patients. Front Physiol 2019; 10:183. [PMID: 30914963 PMCID: PMC6421262 DOI: 10.3389/fphys.2019.00183] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 02/14/2019] [Indexed: 01/15/2023] Open
Abstract
Although model-based solution strategies for the ECGI were reported to deliver promising clinical results, they strongly rely on some a priori assumptions, which do not hold true for many pathological cases. The fastest route algorithm (FRA) is a well-established method for noninvasive imaging of ectopic activities. It generates test activation sequences on the heart and compares the corresponding test body surface potential maps (BSPMs) to the measured ones. The test excitation propagation patterns are constructed under the assumption of a global conduction velocity in the heart, which is violated in the cardiac resynchronization (CRT) patients suffering from conduction disturbances. In the present work, we propose to apply dynamic time warping (DTW) to the test and measured ECGs before measuring their similarity. The warping step is a non-linear pattern matching that compensates for local delays in the temporal sequences, thus accounting for the inhomogeneous excitation propagation, while aligning them in an optimal way with respect to a distance function. To evaluate benefits of the temporal warping for FRA-based BSPMs, we considered three scenarios. In the first setting, a simplified simulation example was constructed to illustrate the temporal warping and display the resulting distance map. Then, we applied the proposed method to eight BSPMs produced by realistic ectopic activation sequences and compared its performance to FRA. Finally, we assessed localization accuracy of both techniques in ten CRT patients. For each patient, we noninvasively imaged two paced ECGs: from left and right ventricular implanted leads. In all scenarios, FRA-DTW outperformed FRA in terms of LEs. For the clinical cases, the median (25-75% range) distance errors were reduced from 16 (8-23)mm to 5 (2-10)mm for all pacings, from 15 (11-25)mm to 8 (3-13)mm in the left, and from 19 (6-23)mm to 4 (2-8)mm in the right ventricle, respectively. The obtained results suggest the ability of temporal ECG warping to compensate for an inhomogeneous conduction profile, while retaining computational efficiency intrinsic to FRA.
Collapse
Affiliation(s)
| | - Mikhail Chmelevsky
- EP Solutions SA, Yverdon-les-Bains, Switzerland.,Almazov National Medical Research Center, Saint Petersburg, Russia
| | - Peter van Dam
- Cardiology Department, University Medical Center Utrecht, Utrecht, Netherlands
| | | | - Stepan Zubarev
- Almazov National Medical Research Center, Saint Petersburg, Russia
| | - Tatjana Treshkur
- Almazov National Medical Research Center, Saint Petersburg, Russia
| | - Dmitry Lebedev
- Almazov National Medical Research Center, Saint Petersburg, Russia
| |
Collapse
|
13
|
Cluitmans M, Brooks DH, MacLeod R, Dössel O, Guillem MS, van Dam PM, Svehlikova J, He B, Sapp J, Wang L, Bear L. Validation and Opportunities of Electrocardiographic Imaging: From Technical Achievements to Clinical Applications. Front Physiol 2018; 9:1305. [PMID: 30294281 PMCID: PMC6158556 DOI: 10.3389/fphys.2018.01305] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Accepted: 08/29/2018] [Indexed: 11/23/2022] Open
Abstract
Electrocardiographic imaging (ECGI) reconstructs the electrical activity of the heart from a dense array of body-surface electrocardiograms and a patient-specific heart-torso geometry. Depending on how it is formulated, ECGI allows the reconstruction of the activation and recovery sequence of the heart, the origin of premature beats or tachycardia, the anchors/hotspots of re-entrant arrhythmias and other electrophysiological quantities of interest. Importantly, these quantities are directly and non-invasively reconstructed in a digitized model of the patient's three-dimensional heart, which has led to clinical interest in ECGI's ability to personalize diagnosis and guide therapy. Despite considerable development over the last decades, validation of ECGI is challenging. Firstly, results depend considerably on implementation choices, which are necessary to deal with ECGI's ill-posed character. Secondly, it is challenging to obtain (invasive) ground truth data of high quality. In this review, we discuss the current status of ECGI validation as well as the major challenges remaining for complete adoption of ECGI in clinical practice. Specifically, showing clinical benefit is essential for the adoption of ECGI. Such benefit may lie in patient outcome improvement, workflow improvement, or cost reduction. Future studies should focus on these aspects to achieve broad adoption of ECGI, but only after the technical challenges have been solved for that specific application/pathology. We propose 'best' practices for technical validation and highlight collaborative efforts recently organized in this field. Continued interaction between engineers, basic scientists, and physicians remains essential to find a hybrid between technical achievements, pathological mechanisms insights, and clinical benefit, to evolve this powerful technique toward a useful role in clinical practice.
Collapse
Affiliation(s)
- Matthijs Cluitmans
- Department of Cardiology, Cardiovascular Research Institute Maastricht Maastricht University, Maastricht, Netherlands
| | - Dana H. Brooks
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, United States
| | - Rob MacLeod
- Biomedical Engineering Department, Scientific Computing and Imaging Institute (SCI), and Cardiovascular Research and Training Institute (CVRTI), The University of Utah, Salt Lake City, UT, United States
| | - Olaf Dössel
- Karlsruhe Institute of Technology, Karlsruhe, Germany
| | | | - Peter M. van Dam
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen Medical Center, Nijmegen, Netherlands
| | - Jana Svehlikova
- Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Bin He
- Department of Biomedical Engineering Carnegie Mellon University, Pittsburgh, PA, United States
| | - John Sapp
- QEII Health Sciences Centre and Department of Medicine, Dalhousie University, Halifax, NS, Canada
| | - Linwei Wang
- Rochester Institute of Technology, Rochester, NY, United States
| | - Laura Bear
- IHU LIRYC, Fondation Bordeaux Université, Inserm U1045 and Université de Bordeaux, Bordeaux, France
| |
Collapse
|
14
|
Potse M. Scalable and Accurate ECG Simulation for Reaction-Diffusion Models of the Human Heart. Front Physiol 2018; 9:370. [PMID: 29731720 PMCID: PMC5920200 DOI: 10.3389/fphys.2018.00370] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Accepted: 03/27/2018] [Indexed: 11/13/2022] Open
Abstract
Realistic electrocardiogram (ECG) simulation with numerical models is important for research linking cellular and molecular physiology to clinically observable signals, and crucial for patient tailoring of numerical heart models. However, ECG simulation with a realistic torso model is computationally much harder than simulation of cardiac activity itself, so that many studies with sophisticated heart models have resorted to crude approximations of the ECG. This paper shows how the classical concept of electrocardiographic lead fields can be used for an ECG simulation method that matches the realism of modern heart models. The accuracy and resource requirements were compared to those of a full-torso solution for the potential and scaling was tested up to 14,336 cores with a heart model consisting of 11 million nodes. Reference ECGs were computed on a 3.3 billion-node heart-torso mesh at 0.2 mm resolution. The results show that the lead-field method is more efficient than a full-torso solution when the number of simulated samples is larger than the number of computed ECG leads. While the initial computation of the lead fields remains a hard and poorly scalable problem, the ECG computation itself scales almost perfectly and, even for several hundreds of ECG leads, takes much less time than the underlying simulation of cardiac activity.
Collapse
Affiliation(s)
- Mark Potse
- CARMEN Research Team, Inria Bordeaux Sud-Ouest, Talence, France.,Institut de Mathématiques de Bordeaux, UMR 5251, Université de Bordeaux, Talence, France.,IHU Liryc, Electrophysiology and Heart Modeling Institute, Foundation Bordeaux Université, Pessac-Bordeaux, France
| |
Collapse
|