1
|
Hazarika D, Vishnu KN, Ransing R, Gupta CN. Dynamical Embedding of Single-Channel Electroencephalogram for Artifact Subspace Reconstruction. SENSORS (BASEL, SWITZERLAND) 2024; 24:6734. [PMID: 39460214 PMCID: PMC11510769 DOI: 10.3390/s24206734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2024] [Revised: 10/07/2024] [Accepted: 10/12/2024] [Indexed: 10/28/2024]
Abstract
This study introduces a novel framework to apply the artifact subspace reconstruction (ASR) algorithm on single-channel electroencephalogram (EEG) data. ASR is known for its ability to remove artifacts like eye-blinks and movement but traditionally relies on multiple channels. Embedded ASR (E-ASR) addresses this by incorporating a dynamical embedding approach. In this method, an embedded matrix is created from single-channel EEG data using delay vectors, followed by ASR application and reconstruction of the cleaned signal. Data from four subjects with eyes open were collected using Fp1 and Fp2 electrodes via the CameraEEG android app. The E-ASR algorithm was evaluated using metrics like relative root mean square error (RRMSE), correlation coefficient (CC), and average power ratio. The number of eye-blinks with and without the E-ASR approach was also estimated. E-ASR achieved an RRMSE of 43.87% and had a CC of 0.91 on semi-simulated data and effectively reduced artifacts in real EEG data, with eye-blink counts validated against ground truth video data. This framework shows potential for smartphone-based EEG applications in natural environments with minimal electrodes.
Collapse
Affiliation(s)
- Doli Hazarika
- Neural Engineering Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology, Guwahati 781039, India; (D.H.); (K.N.V.)
| | - K. N. Vishnu
- Neural Engineering Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology, Guwahati 781039, India; (D.H.); (K.N.V.)
| | - Ramdas Ransing
- Department of Psychiatry, Clinical Neurosciences, and Addiction Medicine, All India Institute of Medical Sciences, Guwahati 781101, India;
| | - Cota Navin Gupta
- Neural Engineering Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology, Guwahati 781039, India; (D.H.); (K.N.V.)
| |
Collapse
|
2
|
Ronca V, Capotorto R, Di Flumeri G, Giorgi A, Vozzi A, Germano D, Virgilio VD, Borghini G, Cartocci G, Rossi D, Inguscio BMS, Babiloni F, Aricò P. Optimizing EEG Signal Integrity: A Comprehensive Guide to Ocular Artifact Correction. Bioengineering (Basel) 2024; 11:1018. [PMID: 39451394 PMCID: PMC11505294 DOI: 10.3390/bioengineering11101018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2024] [Revised: 09/30/2024] [Accepted: 10/08/2024] [Indexed: 10/26/2024] Open
Abstract
Ocular artifacts, including blinks and saccades, pose significant challenges in the analysis of electroencephalographic (EEG) data, often obscuring crucial neural signals. This tutorial provides a comprehensive guide to the most effective methods for correcting these artifacts, with a focus on algorithms designed for both laboratory and real-world settings. We review traditional approaches, such as regression-based techniques and Independent Component Analysis (ICA), alongside more advanced methods like Artifact Subspace Reconstruction (ASR) and deep learning-based algorithms. Through detailed step-by-step instructions and comparative analysis, this tutorial equips researchers with the tools necessary to maintain the integrity of EEG data, ensuring accurate and reliable results in neurophysiological studies. The strategies discussed are particularly relevant for wearable EEG systems and real-time applications, reflecting the growing demand for robust and adaptable solutions in applied neuroscience.
Collapse
Affiliation(s)
- Vincenzo Ronca
- Department of Computer, Control, and Management Engineering, Sapienza University of Rome, 00185 Roma, Italy; (D.G.); (V.D.V.); (B.M.S.I.); or (P.A.)
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
| | - Rossella Capotorto
- Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, 00185 Roma, Italy;
| | - Gianluca Di Flumeri
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
- Department of Molecular Medicine, Sapienza University of Rome, 00185 Roma, Italy;
| | - Andrea Giorgi
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
- Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, 00185 Roma, Italy;
| | - Alessia Vozzi
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
| | - Daniele Germano
- Department of Computer, Control, and Management Engineering, Sapienza University of Rome, 00185 Roma, Italy; (D.G.); (V.D.V.); (B.M.S.I.); or (P.A.)
| | - Valerio Di Virgilio
- Department of Computer, Control, and Management Engineering, Sapienza University of Rome, 00185 Roma, Italy; (D.G.); (V.D.V.); (B.M.S.I.); or (P.A.)
| | - Gianluca Borghini
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
- Department of Molecular Medicine, Sapienza University of Rome, 00185 Roma, Italy;
| | - Giulia Cartocci
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
- Department of Molecular Medicine, Sapienza University of Rome, 00185 Roma, Italy;
| | - Dario Rossi
- Department of Molecular Medicine, Sapienza University of Rome, 00185 Roma, Italy;
| | - Bianca M. S. Inguscio
- Department of Computer, Control, and Management Engineering, Sapienza University of Rome, 00185 Roma, Italy; (D.G.); (V.D.V.); (B.M.S.I.); or (P.A.)
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
| | - Fabio Babiloni
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
- Department of Physiology and Pharmacology “Vittorio Erspamer”, Sapienza University of Rome, Piazzale Aldo Moro 5, 00185 Rome, Italy
- College of Computer Science and Technology, Hangzhou Dianzi University, Hangzhou 310005, China
| | - Pietro Aricò
- Department of Computer, Control, and Management Engineering, Sapienza University of Rome, 00185 Roma, Italy; (D.G.); (V.D.V.); (B.M.S.I.); or (P.A.)
- BrainSigns S.r.l., Industrial Neurosciences Lab, 00198 Rome, Italy; (G.D.F.); (A.G.); (A.V.); (G.B.); (G.C.); (F.B.)
| |
Collapse
|
3
|
Cataldi J, Stephan AM, Haba-Rubio J, Siclari F. Shared EEG correlates between non-REM parasomnia experiences and dreams. Nat Commun 2024; 15:3906. [PMID: 38724511 PMCID: PMC11082195 DOI: 10.1038/s41467-024-48337-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Accepted: 04/26/2024] [Indexed: 05/12/2024] Open
Abstract
Sleepwalking and related parasomnias result from incomplete awakenings out of non-rapid eye movement sleep. Behavioral episodes can occur without consciousness or recollection, or in relation to dream-like experiences. To understand what accounts for these differences in consciousness and recall, here we recorded parasomnia episodes with high-density electroencephalography (EEG) and interviewed participants immediately afterward about their experiences. Compared to reports of no experience (19%), reports of conscious experience (56%) were preceded by high-amplitude EEG slow waves in anterior cortical regions and activation of posterior cortical regions, similar to previously described EEG correlates of dreaming. Recall of the content of the experience (56%), compared to no recall (25%), was associated with higher EEG activation in the right medial temporal region before movement onset. Our work suggests that the EEG correlates of parasomnia experiences are similar to those reported for dreams and may thus reflect core physiological processes involved in sleep consciousness.
Collapse
Affiliation(s)
- Jacinthe Cataldi
- Center for Investigation and Research on Sleep, Lausanne University Hospital, Lausanne, Switzerland
- The Sense Innovation and Research Center, Lausanne and Sion, Lausanne, Switzerland
| | - Aurélie M Stephan
- Center for Investigation and Research on Sleep, Lausanne University Hospital, Lausanne, Switzerland
- The Sense Innovation and Research Center, Lausanne and Sion, Lausanne, Switzerland
- The Netherlands Institute for Neuroscience, Amsterdam, The Netherlands
| | - José Haba-Rubio
- Center for Investigation and Research on Sleep, Lausanne University Hospital, Lausanne, Switzerland
| | - Francesca Siclari
- Center for Investigation and Research on Sleep, Lausanne University Hospital, Lausanne, Switzerland.
- The Sense Innovation and Research Center, Lausanne and Sion, Lausanne, Switzerland.
- The Netherlands Institute for Neuroscience, Amsterdam, The Netherlands.
| |
Collapse
|
4
|
Miyakoshi M, Kim H, Nakanishi M, Palmer J, Kanayama N. One out of ten independent components shows flipped polarity with poorer data quality: EEG database study. Hum Brain Mapp 2024; 45:e26540. [PMID: 38069570 PMCID: PMC10789196 DOI: 10.1002/hbm.26540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 10/30/2023] [Accepted: 11/07/2023] [Indexed: 01/16/2024] Open
Abstract
Independent component analysis (ICA) is widely used today for scalp-recorded EEG analysis. One of the limitations of ICA-based analysis is polarity indeterminacy. It is not easy to find detailed documentations that explains engineering solutions of how the polarity indeterminacy is addressed in a given implementation. We investigated how it is implemented in the case of EEGLAB and also the relation between the outcome of the polarity determination and classification of independent components (ICs) in terms of the estimated nature of the sources (brain, muscle, eye, etc.) using an open database of n = 212 EEG dataset of resting state recordings. We found that (1) about 91% of ICs showed positive-dominant IC scalp topographies; (2) positive-dominant ICs were more associated with brain-originated signals; (3) positive-dominant ICs showed more radial (peaked at 10-30 degrees deviations from the radial axis) dipolar projection pattern with less residual variance from fitting the equivalent current dipole. In conclusion, using the EEGLAB's default ICA algorithm, one out of 10 ICs results in flipping its polarity to negative, which is associated with non-radial dipole orientation with higher residual variance. Thus, we determined EEGLAB biases toward positive polarity in decomposing high-quality brain ICs.
Collapse
Affiliation(s)
- Makoto Miyakoshi
- Division of Child and Adolescent PsychiatryCincinnati Children's Hospital Medical CenterCincinnatiOhioUSA
- Department of MedicineUniversity of Cincinnati College of MedicineCincinnatiOhioUSA
- Swartz Center for Computational NeuroscienceInstitute for Neural Computation, University of California San DiegoLa JollaCaliforniaUSA
| | - Hyeonseok Kim
- Swartz Center for Computational NeuroscienceInstitute for Neural Computation, University of California San DiegoLa JollaCaliforniaUSA
| | - Masaki Nakanishi
- Swartz Center for Computational NeuroscienceInstitute for Neural Computation, University of California San DiegoLa JollaCaliforniaUSA
| | - Jason Palmer
- School of Mathematical and Data SciencesWest Virginia UniversityMorgantownWest VirginiaUSA
| | - Noriaki Kanayama
- Human Informatics and Interaction Research Institute, National Institute of Advanced Industrial Science and Technology (AIST)TokyoJapan
- Center for Brain, Mind and KANSEI Sciences ResearchHiroshima UniversityTokyoJapan
| |
Collapse
|
5
|
Miyakoshi M. Artifact subspace reconstruction: a candidate for a dream solution for EEG studies, sleep or awake. Sleep 2023; 46:zsad241. [PMID: 37715954 PMCID: PMC10710985 DOI: 10.1093/sleep/zsad241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Indexed: 09/18/2023] Open
Affiliation(s)
- Makoto Miyakoshi
- Division of Child and Adolescent Psychiatry, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA
- Department of Psychiatry, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
6
|
Somervail R, Cataldi J, Stephan AM, Siclari F, Iannetti GD. Dusk2Dawn: an EEGLAB plugin for automatic cleaning of whole-night sleep electroencephalogram using Artifact Subspace Reconstruction. Sleep 2023; 46:zsad208. [PMID: 37542730 DOI: 10.1093/sleep/zsad208] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 07/20/2023] [Indexed: 08/07/2023] Open
Abstract
Whole-night sleep electroencephalogram (EEG) is plagued by several types of large-amplitude artifacts. Common approaches to remove them are fraught with issues: channel interpolation, rejection of noisy intervals, and independent component analysis are time-consuming, rely on subjective user decisions, and result in signal loss. Artifact Subspace Reconstruction (ASR) is an increasingly popular approach to rapidly and automatically clean wake EEG data. Indeed, ASR adaptively removes large-amplitude artifacts regardless of their scalp topography or consistency throughout the recording. This makes ASR, at least in theory, a highly-promising tool to clean whole-night EEG. However, ASR crucially relies on calibration against a subset of relatively clean "baseline" data. This is problematic when the baseline changes substantially over time, as in whole-night EEG data. Here we tackled this issue and, for the first time, validated ASR for cleaning sleep EEG. We demonstrate that ASR applied out-of-the-box, with the parameters recommended for wake EEG, results in the dramatic removal of slow waves. We also provide an appropriate procedure to use ASR for automatic and rapid cleaning of whole-night sleep EEG data or any long EEG recording. Our procedure is freely available in Dusk2Dawn, an open-source plugin for EEGLAB.
Collapse
Affiliation(s)
- Richard Somervail
- Neuroscience and Behaviour Laboratory, Italian Institute of Technology (IIT), Rome, Italy
- Department of Neuroscience Physiology and Pharmacology, University College London (UCL), London, UK
| | - Jacinthe Cataldi
- Centre d'Investigation et de Recherche sur le Sommeil, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
- The Sense Innovation and Research Center, Lausanne and Sion, Switzerland
| | - Aurélie M Stephan
- Centre d'Investigation et de Recherche sur le Sommeil, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
- The Sense Innovation and Research Center, Lausanne and Sion, Switzerland
- Netherlands Institute for Neuroscience, Amsterdam, The Netherlands
| | - Francesca Siclari
- Centre d'Investigation et de Recherche sur le Sommeil, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
- The Sense Innovation and Research Center, Lausanne and Sion, Switzerland
- Netherlands Institute for Neuroscience, Amsterdam, The Netherlands
| | - Gian Domenico Iannetti
- Neuroscience and Behaviour Laboratory, Italian Institute of Technology (IIT), Rome, Italy
- Department of Neuroscience Physiology and Pharmacology, University College London (UCL), London, UK
| |
Collapse
|
7
|
Caruso VC, Wray AH, Lescht E, Chang SE. Neural oscillatory activity and connectivity in children who stutter during a non-speech motor task. J Neurodev Disord 2023; 15:40. [PMID: 37964200 PMCID: PMC10647051 DOI: 10.1186/s11689-023-09507-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 10/25/2023] [Indexed: 11/16/2023] Open
Abstract
BACKGROUND Neural motor control rests on the dynamic interaction of cortical and subcortical regions, which is reflected in the modulation of oscillatory activity and connectivity in multiple frequency bands. Motor control is thought to be compromised in developmental stuttering, particularly involving circuits in the left hemisphere that support speech, movement initiation, and timing control. However, to date, evidence comes from adult studies, with a limited understanding of motor processes in childhood, closer to the onset of stuttering. METHODS We investigated the neural control of movement initiation in children who stutter and children who do not stutter by evaluating transient changes in EEG oscillatory activity (power, phase locking to button press) and connectivity (phase synchronization) during a simple button press motor task. We compared temporal changes in these oscillatory dynamics between the left and right hemispheres and between children who stutter and children who do not stutter, using mixed-model analysis of variance. RESULTS We found reduced modulation of left hemisphere oscillatory power, phase locking to button press and phase connectivity in children who stutter compared to children who do not stutter, consistent with previous findings of dysfunction within the left sensorimotor circuits. Interhemispheric connectivity was weaker at lower frequencies (delta, theta) and stronger in the beta band in children who stutter than in children who do not stutter. CONCLUSIONS Taken together, these findings indicate weaker engagement of the contralateral left motor network in children who stutter even during low-demand non-speech tasks, and suggest that the right hemisphere might be recruited to support sensorimotor processing in childhood stuttering. Differences in oscillatory dynamics occurred despite comparable task performance between groups, indicating that an altered balance of cortical activity might be a core aspect of stuttering, observable during normal motor behavior.
Collapse
Affiliation(s)
- Valeria C Caruso
- Department of Psychiatry, University of Michigan, Ann Arbor, MI, USA.
- Department of Psychology, University of Michigan, Ann Arbor, MI, USA.
| | - Amanda Hampton Wray
- Department of Communication Science & Disorders, University of Pittsburgh, Pittsburgh, PA, USA
| | - Erica Lescht
- Department of Communication Science & Disorders, University of Pittsburgh, Pittsburgh, PA, USA
| | - Soo-Eun Chang
- Department of Psychiatry, University of Michigan, Ann Arbor, MI, USA
- Department of Communication Disorders, Ewha Womans University, Seoul, South Korea
| |
Collapse
|
8
|
Becker L, Büchel D, Lehmann T, Kehne M, Baumeister J. Mobile Electroencephalography Reveals Differences in Cortical Processing During Exercises With Lower and Higher Cognitive Demands in Preadolescent Children. Pediatr Exerc Sci 2023; 35:214-224. [PMID: 36944368 DOI: 10.1123/pes.2021-0212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 11/23/2022] [Accepted: 12/07/2022] [Indexed: 03/23/2023]
Abstract
PURPOSE The aim of this study was to examine whether cortical activity changes during exercise with increasing cognitive demands in preadolescent children. METHOD Twenty healthy children (8.75 [0.91] y) performed one movement game, which was conducted with lower and higher cognitive demands. During a baseline measurement and both exercise conditions, cortical activity was recorded using a 64-channel electroencephalographic system, and heart rate was assessed. Ratings of perceived excertion and perceived cognitive engagement were examined after each condition. To analyze power spectral density in the theta, alpha-1, and alpha-2 frequency bands, an adaptive mixture independent component analysis was used to determine the spatiotemporal sources of cortical activity, and brain components were clustered to identify spatial clusters. RESULTS One-way repeated-measures analyses of variance revealed significant main effects for condition on theta in the prefrontal cluster, on alpha-1 in the prefrontal, central, bilateral motor, bilateral parieto-occipital, and occipital clusters, and on alpha-2 in the left motor, central, and left parieto-occipital clusters. Compared with the lower cognitive demand exercise, cortical activity was significantly higher in theta power in the prefrontal cluster and in alpha-1 power in the occipital cluster during the higher cognitive demand exercise. CONCLUSION The present study shows that exercise complexity seems to influence cortical processing as it increased with increasing cognitive demands.
Collapse
Affiliation(s)
- Linda Becker
- Department of Exercise & Health, Exercise Science and Neuroscience Unit, Faculty of Science, Paderborn University, Paderborn,Germany
| | - Daniel Büchel
- Department of Exercise & Health, Exercise Science and Neuroscience Unit, Faculty of Science, Paderborn University, Paderborn,Germany
| | - Tim Lehmann
- Department of Exercise & Health, Exercise Science and Neuroscience Unit, Faculty of Science, Paderborn University, Paderborn,Germany
| | - Miriam Kehne
- Department of Exercise & Health, Childhood and Youth Research in Sports, Faculty of Science, Paderborn University, Paderborn,Germany
| | - Jochen Baumeister
- Department of Exercise & Health, Exercise Science and Neuroscience Unit, Faculty of Science, Paderborn University, Paderborn,Germany
| |
Collapse
|
9
|
Schmoigl-Tonis M, Schranz C, Müller-Putz GR. Methods for motion artifact reduction in online brain-computer interface experiments: a systematic review. Front Hum Neurosci 2023; 17:1251690. [PMID: 37920561 PMCID: PMC10619676 DOI: 10.3389/fnhum.2023.1251690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Accepted: 09/11/2023] [Indexed: 11/04/2023] Open
Abstract
Brain-computer interfaces (BCIs) have emerged as a promising technology for enhancing communication between the human brain and external devices. Electroencephalography (EEG) is particularly promising in this regard because it has high temporal resolution and can be easily worn on the head in everyday life. However, motion artifacts caused by muscle activity, fasciculation, cable swings, or magnetic induction pose significant challenges in real-world BCI applications. In this paper, we present a systematic review of methods for motion artifact reduction in online BCI experiments. Using the PRISMA filter method, we conducted a comprehensive literature search on PubMed, focusing on open access publications from 1966 to 2022. We evaluated 2,333 publications based on predefined filtering rules to identify existing methods and pipelines for motion artifact reduction in EEG data. We present a lookup table of all papers that passed the defined filters, all used methods, and pipelines and compare their overall performance and suitability for online BCI experiments. We summarize suitable methods, algorithms, and concepts for motion artifact reduction in online BCI applications, highlight potential research gaps, and discuss existing community consensus. This review aims to provide a comprehensive overview of the current state of the field and guide researchers in selecting appropriate methods for motion artifact reduction in online BCI experiments.
Collapse
Affiliation(s)
- Mathias Schmoigl-Tonis
- Laboratory of Collaborative Robotics, Department of Human Motion Analytics, Salzburg Research GmbH, Salzburg, Austria
- Institute of Neural Engineering, Laboratory of Brain-Computer Interfaces, Graz University of Technology, Graz, Austria
| | - Christoph Schranz
- Laboratory of Collaborative Robotics, Department of Human Motion Analytics, Salzburg Research GmbH, Salzburg, Austria
| | - Gernot R. Müller-Putz
- Institute of Neural Engineering, Laboratory of Brain-Computer Interfaces, Graz University of Technology, Graz, Austria
- BioTechMed Graz, Graz, Austria
| |
Collapse
|
10
|
Monroe DC, Berry NT, Fino PC, Rhea CK. A Dynamical Systems Approach to Characterizing Brain-Body Interactions during Movement: Challenges, Interpretations, and Recommendations. SENSORS (BASEL, SWITZERLAND) 2023; 23:6296. [PMID: 37514591 PMCID: PMC10385586 DOI: 10.3390/s23146296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 06/16/2023] [Accepted: 06/20/2023] [Indexed: 07/30/2023]
Abstract
Brain-body interactions (BBIs) have been the focus of intense scrutiny since the inception of the scientific method, playing a foundational role in the earliest debates over the philosophy of science. Contemporary investigations of BBIs to elucidate the neural principles of motor control have benefited from advances in neuroimaging, device engineering, and signal processing. However, these studies generally suffer from two major limitations. First, they rely on interpretations of 'brain' activity that are behavioral in nature, rather than neuroanatomical or biophysical. Second, they employ methodological approaches that are inconsistent with a dynamical systems approach to neuromotor control. These limitations represent a fundamental challenge to the use of BBIs for answering basic and applied research questions in neuroimaging and neurorehabilitation. Thus, this review is written as a tutorial to address both limitations for those interested in studying BBIs through a dynamical systems lens. First, we outline current best practices for acquiring, interpreting, and cleaning scalp-measured electroencephalography (EEG) acquired during whole-body movement. Second, we discuss historical and current theories for modeling EEG and kinematic data as dynamical systems. Third, we provide worked examples from both canonical model systems and from empirical EEG and kinematic data collected from two subjects during an overground walking task.
Collapse
Affiliation(s)
- Derek C Monroe
- Department of Kinesiology, University of North Carolina at Greensboro, Greensboro, NC 27402, USA
| | - Nathaniel T Berry
- Department of Kinesiology, University of North Carolina at Greensboro, Greensboro, NC 27402, USA
- Under Armour, Inc., Innovation, Baltimore, MD 21230, USA
| | - Peter C Fino
- Department of Health and Kinesiology, University of Utah, Salt Lake City, UT 84112, USA
| | - Christopher K Rhea
- College of Health Sciences, Old Dominion University, Norfolk, VA 23508, USA
| |
Collapse
|
11
|
Koul A, Ahmar D, Iannetti GD, Novembre G. Spontaneous dyadic behaviour predicts the emergence of interpersonal neural synchrony. Neuroimage 2023:120233. [PMID: 37348621 DOI: 10.1016/j.neuroimage.2023.120233] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 06/14/2023] [Accepted: 06/15/2023] [Indexed: 06/24/2023] Open
Abstract
Synchronization of neural activity across brains - interpersonal neural synchrony (INS) - is emerging as a powerful marker of social interaction that predicts success of multi-person coordination, communication, and cooperation. As the origins of INS are poorly understood, we tested whether and how INS might emerge from spontaneous dyadic behavior. We recorded neural activity (EEG) and human behavior (full-body kinematics, eye movements and facial expressions) while dyads of participants were instructed to look at each other without speaking or making co-verbal gestures. We made four fundamental observations. First, despite the absence of a structured social task, INS emerged spontaneously only when participants were able to see each other. Second, we show that such spontaneous INS, comprising specific spectral and topographic profiles, did not merely reflect intra-personal modulations of neural activity, but it rather reflected real-time and dyad-specific coupling of neural activities. Third, using state-of-art video-image processing and deep learning, we extracted the temporal unfolding of three notable social behavioral cues - body movement, eye contact, and smiling - and demonstrated that these behaviors also spontaneously synchronized within dyads. Fourth, we probed the correlates of INS in such synchronized social behaviors. Using cross-correlation and Granger causality analyses, we show that synchronized social behaviors anticipate and in fact Granger cause INS. These results provide proof-of-concept evidence for studying interpersonal neural and behavioral synchrony under natural and unconstrained conditions. Most importantly, the results suggest that INS could be conceptualized as an emergent property of two coupled neural systems: an entrainment phenomenon, promoted by real-time dyadic behavior.
Collapse
Affiliation(s)
- Atesh Koul
- Neuroscience of Perception and Action Lab, Italian Institute of Technology (IIT), Viale Regina Elena 291, Rome, Italy.
| | - Davide Ahmar
- Neuroscience of Perception and Action Lab, Italian Institute of Technology (IIT), Viale Regina Elena 291, Rome, Italy
| | - Gian Domenico Iannetti
- Neuroscience and Behavior Lab, Italian Institute of Technology (IIT), Viale Regina Elena 291, Rome, Italy; Department of Neuroscience, Physiology and Pharmacology, University College London (UCL), WC1E 6BT, London, UK
| | - Giacomo Novembre
- Neuroscience of Perception and Action Lab, Italian Institute of Technology (IIT), Viale Regina Elena 291, Rome, Italy.
| |
Collapse
|
12
|
Tsai BY, Diddi SVS, Ko LW, Wang SJ, Chang CY, Jung TP. Development of an Adaptive Artifact Subspace Reconstruction Based on Hebbian/Anti-Hebbian Learning Networks for Enhancing BCI Performance. IEEE TRANSACTIONS ON NEURAL NETWORKS AND LEARNING SYSTEMS 2022; PP:348-361. [PMID: 35714085 DOI: 10.1109/tnnls.2022.3174528] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Brain-computer interface (BCI) actively translates the brain signals into executable actions by establishing direct communication between the human brain and external devices. Recording brain activity through electroencephalography (EEG) is generally contaminated with both physiological and nonphysiological artifacts, which significantly hinders the BCI performance. Artifact subspace reconstruction (ASR) is a well-known statistical technique that automatically removes artifact components by determining the rejection threshold based on the initial reference EEG segment in multichannel EEG recordings. In real-world applications, the fixed threshold may limit the efficacy of the artifact correction, especially when the quality of the reference data is poor. This study proposes an adaptive online ASR technique by integrating the Hebbian/anti-Hebbian neural networks into the ASR algorithm, namely, principle subspace projection ASR (PSP-ASR) and principal subspace whitening ASR (PSW-ASR) that segmentwise self-organize the artifact subspace by updating the synaptic weights according to the Hebbian and anti-Hebbian learning rules. The effectiveness of the proposed algorithm is compared to the conventional ASR approaches on benchmark EEG dataset and three BCI frameworks, including steady-state visual evoked potential (SSVEP), rapid serial visual presentation (RSVP), and motor imagery (MI) by evaluating the root-mean-square error (RMSE), the signal-to-noise ratio (SNR), the Pearson correlation, and classification accuracy. The results demonstrated that the PSW-ASR algorithm effectively removed the EEG artifacts and retained the activity-specific brain signals compared to the PSP-ASR, standard ASR (Init-ASR), and moving-window ASR (MW-ASR) methods, thereby enhancing the SSVEP, RSVP, and MI BCI performances. Finally, our empirical results from the PSW-ASR algorithm suggested the choice of an aggressive cutoff range of c = 1-10 for activity-specific BCI applications and a moderate range of for the benchmark dataset and general BCI applications.
Collapse
|
13
|
Auger E, Berry-Kravis EM, Ethridge LE. Independent evaluation of the harvard automated processing pipeline for Electroencephalography 1.0 using multi-site EEG data from children with Fragile X Syndrome. J Neurosci Methods 2022; 371:109501. [PMID: 35182604 PMCID: PMC8962770 DOI: 10.1016/j.jneumeth.2022.109501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 02/07/2022] [Accepted: 02/08/2022] [Indexed: 11/17/2022]
Abstract
BACKGROUND The Harvard Automatic Processing Pipeline for Electroencephalography (HAPPE) is a computerized EEG data processing pipeline designed for multiple site analysis of populations with neurodevelopmental disorders. This pipeline has been validated in-house by the developers but external testing using real-world datasets remains to be done. NEW METHOD Resting and auditory event-related EEG data from 29 children ages 3-6 years with Fragile X Syndrome as well as simulated EEG data was used to evaluate HAPPE's noise reduction techniques, data standardization features, and data integration compared to traditional manualized processing. RESULTS For the real EEG data, HAPPE pipeline showed greater trials retained, greater variance retained through independent component analysis (ICA) component removal, and smaller kurtosis than the manual pipeline; the manual pipeline had a significantly larger signal-to-noise ratio (SNR). For simulated EEG data, correlation between the pure signal and processed data was significantly higher for manually-processed data compared to HAPPE-processed data. Hierarchical linear modeling showed greater signal recovery in the manual pipeline with the exception of the gamma band signal which showed mixed results. COMPARISON WITH EXISTING METHODS SNR and simulated signal retention was significantly greater in the manually-processed data than the HAPPE-processed data. Signal reduction may negatively affect outcome measures. CONCLUSIONS The HAPPE pipeline benefits from less active processing time and artifact reduction without removing segments. However, HAPPE may bias toward elimination of noise at the cost of signal. Recommended implementation of the HAPPE pipeline for neurodevelopmental populations depends on the goals and priorities of the research.
Collapse
Affiliation(s)
- Emma Auger
- Department of Psychology, University of Oklahoma, Norman, OK 73019-2007, USA
| | - Elizabeth M Berry-Kravis
- Department of Pediatrics, Neurological Sciences, and Biochemistry, Rush University Medical Center, Chicago, IL 60612, USA
| | - Lauren E Ethridge
- Department of Psychology, University of Oklahoma, Norman, OK 73019-2007, USA; Department of Pediatrics, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA.
| |
Collapse
|
14
|
Gorjan D, Gramann K, De Pauw K, Marusic U. Removal of movement-induced EEG artifacts: current state of the art and guidelines. J Neural Eng 2022; 19. [PMID: 35147512 DOI: 10.1088/1741-2552/ac542c] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 02/08/2022] [Indexed: 11/12/2022]
Abstract
Electroencephalography (EEG) is a non-invasive technique used to record cortical neurons' electrical activity using electrodes placed on the scalp. It has become a promising avenue for research beyond state-of-the-art EEG research that is conducted under static conditions. EEG signals are always contaminated by artifacts and other physiological signals. Artifact contamination increases with the intensity of movement. In the last decade (since 2010), researchers have started to implement EEG measurements in dynamic setups to increase the overall ecological validity of the studies. Many different methods are used to remove non-brain activity from the EEG signal, and there are no clear guidelines on which method should be used in dynamic setups and for specific movement intensities. Currently, the most common methods for removing artifacts in movement studies are methods based on independent component analysis (ICA). However, the choice of method for artifact removal depends on the type and intensity of movement, which affects the characteristics of the artifacts and the EEG parameters of interest. When dealing with EEG under non-static conditions, special care must be taken already in the designing period of an experiment. Software and hardware solutions must be combined to achieve sufficient removal of unwanted signals from EEG measurements. We have provided recommendations for the use of each method depending on the intensity of the movement and highlighted the advantages and disadvantages of the methods. However, due to the current gap in the literature, further development and evaluation of methods for artifact removal in EEG data during locomotion is needed.
Collapse
Affiliation(s)
- Dasa Gorjan
- Science and Research Centre Koper, Garibaldijeva 1, Koper, 6000, SLOVENIA
| | - Klaus Gramann
- Technische Universität Berlin, Fasanenstr. 1, Berlin, Berlin, 10623, GERMANY
| | - Kevin De Pauw
- Vrije Universiteit Brussel, Pleinlaan 2, Brussel, Brussel, 1050, BELGIUM
| | - Uros Marusic
- Science and Research Centre Koper, Garibaldijeva 1, Koper, 6000, SLOVENIA
| |
Collapse
|
15
|
Kazemi A, Mirian MS, Lee S, McKeown MJ. Galvanic Vestibular Stimulation Effects on EEG Biomarkers of Motor Vigor in Parkinson's Disease. Front Neurol 2021; 12:759149. [PMID: 34803892 PMCID: PMC8599939 DOI: 10.3389/fneur.2021.759149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Accepted: 10/05/2021] [Indexed: 01/18/2023] Open
Abstract
Background: Impaired motor vigor (MV) is a critical aspect of Parkinson's disease (PD) pathophysiology. While MV is predominantly encoded in the basal ganglia, deriving (cortical) EEG measures of MV may provide valuable targets for modulation via galvanic vestibular stimulation (GVS). Objective: To find EEG features predictive of MV and examine the effects of high-frequency GVS. Methods: Data were collected from 20 healthy control (HC) and 18 PD adults performing 30 trials total of a squeeze bulb task with sham or multi-sine (50-100 Hz "GVS1" or 100-150 Hz "GVS2") stimuli. For each trial, we determined the time to reach maximum force after a "Go" signal, defined MV as the inverse of this time, and used the EEG data 1-sec prior to this time for prediction. We utilized 53 standard EEG features, including relative spectral power, harmonic parameters, and amplitude and phase of bispectrum corresponding to standard EEG bands from each of 27 EEG channels. We then used LASSO regression to select a sparse set of features to predict MV. The regression weights were examined, and separate band-specific models were developed by including only band-specific features (Delta, Theta, Alpha-low, Alpha-high, Beta, Gamma). The correlation between MV prediction and measured MV was used to assess model performance. Results: Models utilizing broadband EEG features were capable of accurately predicting MV (controls: 75%, PD: 81% of the variance). In controls, all EEG bands performed roughly equally in predicting MV, while in the PD group, the model using only beta band features did not predict MV well compared to other bands. Despite having minimal effects on the EEG feature values themselves, both GVS stimuli had significant effects on MV and profound effects on MV predictability via the EEG. With the GVS1 stimulus, beta-band activity in PD subjects became more closely associated with MV compared to the sham condition. With GVS2 stimulus, MV could no longer be accurately predicted from the EEG. Conclusions: EEG features can be a proxy for MV. However, GVS stimuli have profound effects on the relationship between EEG and MV, possibly via direct vestibulo-basal ganglia connections not measurable by the EEG.
Collapse
Affiliation(s)
- Alireza Kazemi
- Center for Mind and Brain, Department of Psychology, University of California, Davis, Davis, CA, United States
| | - Maryam S. Mirian
- Pacific Parkinson's Research Centre, Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, BC, Canada
| | - Soojin Lee
- Pacific Parkinson's Research Centre, Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, BC, Canada
- Wellcome Centre for Integrative Neuroimaging (FMRIB), University of Oxford, Oxford, United Kingdom
| | - Martin J. McKeown
- Pacific Parkinson's Research Centre, Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, BC, Canada
- Faculty of Medicine (Neurology), University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|