1
|
Amatu JB, Baudouin C, Trinh L, Labbé A, Buffault J. [Corneal epithelial biomechanics: Resistance to stress and role in healing and remodeling]. J Fr Ophtalmol 2023; 46:287-299. [PMID: 36759249 DOI: 10.1016/j.jfo.2022.09.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Revised: 09/29/2022] [Accepted: 09/29/2022] [Indexed: 02/10/2023]
Abstract
The corneal epithelium is one of the first tissue barriers of the eye against the environment. In recent years, many studies provided better knowledge of its healing, its behavior and its essential role in the optical system of the eye. At the crossroads of basic science and clinical medicine, the study of the mechanical stresses applied to the cornea makes it possible to learn the behavior of epithelial cells and better understand ocular surface disease. We describe herein the current knowledge about the adhesion systems of the corneal epithelium and their resistance to mechanical stress. We will also describe the involvement of these mechanisms in corneal healing and their role in epithelial dynamics. Adhesion molecules of the epithelial cells, especially hemidesmosomes, allow the tissue cohesion required to maintain the integrity of the corneal epithelium against the shearing forces of the eyelids as well as external forces. Their regeneration after a corneal injury is mandatory for the restoration of a healthy epithelium. Mechanotransduction plays a significant role in regulating epithelial cell behavior, and the study of the epithelium's response to mechanical forces helps to better understand the evolution of epithelial profiles after refractive surgery. A better understanding of corneal epithelial biomechanics could also help improve future therapies, particularly in the field of tissue engineering.
Collapse
Affiliation(s)
- J-B Amatu
- Department of Ophthalmology III, CHNO des Quinze-Vingts, IHU FOReSIGHT, 28, rue de Charenton, 75012 Paris, France.
| | - C Baudouin
- Department of Ophthalmology III, CHNO des Quinze-Vingts, IHU FOReSIGHT, 28, rue de Charenton, 75012 Paris, France; Institut de La Vision, Sorbonne Université, Inserm, CNRS, IHU FOReSIGHT, 17, rue Moreau, 75012 Paris, France; Department of Ophthalmology, Ambroise Paré Hospital, AP-HP, University of Versailles Saint-Quentin-en-Yvelines, Boulogne-Billancourt, France
| | - L Trinh
- Department of Ophthalmology III, CHNO des Quinze-Vingts, IHU FOReSIGHT, 28, rue de Charenton, 75012 Paris, France
| | - A Labbé
- Department of Ophthalmology III, CHNO des Quinze-Vingts, IHU FOReSIGHT, 28, rue de Charenton, 75012 Paris, France; Institut de La Vision, Sorbonne Université, Inserm, CNRS, IHU FOReSIGHT, 17, rue Moreau, 75012 Paris, France; Department of Ophthalmology, Ambroise Paré Hospital, AP-HP, University of Versailles Saint-Quentin-en-Yvelines, Boulogne-Billancourt, France
| | - J Buffault
- Department of Ophthalmology III, CHNO des Quinze-Vingts, IHU FOReSIGHT, 28, rue de Charenton, 75012 Paris, France; Institut de La Vision, Sorbonne Université, Inserm, CNRS, IHU FOReSIGHT, 17, rue Moreau, 75012 Paris, France; Department of Ophthalmology, Ambroise Paré Hospital, AP-HP, University of Versailles Saint-Quentin-en-Yvelines, Boulogne-Billancourt, France
| |
Collapse
|
2
|
Cheng Y, Ren T, Wang N. Biomechanical homeostasis in ocular diseases: A mini-review. Front Public Health 2023; 11:1106728. [PMID: 36733902 PMCID: PMC9886686 DOI: 10.3389/fpubh.2023.1106728] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 01/02/2023] [Indexed: 01/18/2023] Open
Abstract
Diabetes mellitus-induced hyperglycemia is responsible for multiple pathological ocular alternations from vasculopathy to biomechanical dyshomeostasis. Biomechanical homeostasis is crucial to maintain the normal physiological condition of the eyes. Biomechanical features vary in eye tissues regarding different anatomical positions, tissue components, and cellular functions. The disturbance in biomechanical homeostasis may result in different ocular diseases. In this review, we provide a preliminary sketch of the latest evidence on the mechano-environment of the eyeball and its possible influencing factors, thereby underscoring the relationship between the dyshomeostasis of ocular biomechanics and common eye diseases (e.g., diabetic retinopathy, keratoconus, glaucoma, spaceflight-associated neuro-ocular syndrome, retinal vein occlusion and myopia, etc.). Together with the reported evidence, we further discuss and postulate the potential role of biomechanical homeostasis in ophthalmic pathology. Some latest strategies to investigate the biomechanical properties in ocular diseases help unveil the pathological changes at multiple scales, offering references for making new diagnostic and treatment strategies targeting mechanobiology.
Collapse
Affiliation(s)
- Ying Cheng
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Tianmin Ren
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Ningli Wang
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China,Collaborative Innovation Center for Brain Disorders, Beijing Institute of Brain Disorders, Capital Medical University, Beijing, China,Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China,*Correspondence: Ningli Wang ✉
| |
Collapse
|
3
|
Guyard G, Restagno F, McGraw JD. Elastohydrodynamic Relaxation of Soft and Deformable Microchannels. PHYSICAL REVIEW LETTERS 2022; 129:204501. [PMID: 36462008 DOI: 10.1103/physrevlett.129.204501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Accepted: 10/12/2022] [Indexed: 06/17/2023]
Abstract
Hydrodynamic flows in compliant channels are of great interest in physiology and microfluidics. In these situations, elastohydrodynamic coupling leads to (i) a nonlinear pressure-vs-flow-rate relation, strongly affecting the hydraulic resistance; and (ii), because of the compliance-enabled volume storage, a finite relaxation time under a stepwise change in pressure. This latter effect remains relatively unexplored, even while the timescale can vary over a decade in typical situations. In this study we provide time-resolved measurements of the relaxation dynamics for thin and soft, rectangular microfluidic channels. We describe our data using a perturbative lubrication approximation of the Stokes equation coupled to linear elasticity, while taking into account the effect of compliance and resistance of the entrance. The modeling allows us to completely describe all of the experimental results. Our Letter is relevant for any microfluidic scenario wherein a time-dependent driving is applied and provides a first step in the dynamical description of compliant channel networks.
Collapse
Affiliation(s)
- Gabriel Guyard
- Gulliver CNRS UMR 7083, PSL Research University, ESPCI Paris, 10 rue Vauquelin, 75005 Paris, France
- IPGG, 6 rue Jean-Calvin, 75005 Paris, France
- Université Paris-Saclay, CNRS, Laboratoire de Physique des Solides, 91405, Orsay, France
| | - Frédéric Restagno
- Université Paris-Saclay, CNRS, Laboratoire de Physique des Solides, 91405, Orsay, France
| | - Joshua D McGraw
- Gulliver CNRS UMR 7083, PSL Research University, ESPCI Paris, 10 rue Vauquelin, 75005 Paris, France
- IPGG, 6 rue Jean-Calvin, 75005 Paris, France
| |
Collapse
|
4
|
Yang S, Zhang J, Tan Y, Wang Y. Unraveling the mechanobiology of cornea: From bench side to the clinic. Front Bioeng Biotechnol 2022; 10:953590. [PMID: 36263359 PMCID: PMC9573972 DOI: 10.3389/fbioe.2022.953590] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 09/06/2022] [Indexed: 11/18/2022] Open
Abstract
The cornea is a transparent, dome-shaped structure on the front part of the eye that serves as a major optic element and a protector from the external environment. Recent evidence shows aberrant alterations of the corneal mechano-environment in development and progression of various corneal diseases. It is, thus, critical to understand how corneal cells sense and respond to mechanical signals in physiological and pathological conditions. In this review, we summarize the corneal mechano-environment and discuss the impact of these mechanical cues on cellular functions from the bench side (in a laboratory research setting). From a clinical perspective, we comprehensively review the mechanical changes of corneal tissue in several cornea-related diseases, including keratoconus, myopia, and keratectasia, following refractive surgery. The findings from the bench side and clinic underscore the involvement of mechanical cues in corneal disorders, which may open a new avenue for development of novel therapeutic strategies by targeting corneal mechanics.
Collapse
Affiliation(s)
- Shu Yang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Institute, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin, China
- Department of Ophthalmology, The First People’s Hospital of Huzhou, Huzhou, Zhejiang, China
| | - Jing Zhang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Institute, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin, China
- School of Optometry, Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Youhua Tan
- Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen, China
- Department of Biomedical Engineering, Hong Kong Polytechnic University, Hong Kong SAR, China
- *Correspondence: Youhua Tan, ; Yan Wang,
| | - Yan Wang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Institute, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin, China
- *Correspondence: Youhua Tan, ; Yan Wang,
| |
Collapse
|
5
|
Finite Element Analysis of Cornea and Lid Wiper during Blink, with and without Contact Lens. J Ophthalmol 2022; 2022:7930334. [PMID: 35620413 PMCID: PMC9129998 DOI: 10.1155/2022/7930334] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Accepted: 04/26/2022] [Indexed: 11/18/2022] Open
Abstract
Ocular surface disorders such as Lid Wiper Epitheliopathy (LWE), Superior Epithelial Arcuate Lesion (SEAL), and contact lens-induced Limbal Stem Cell Deficiency (LSCD) as well as Superior Limbic Keratoconjunctivitis (SLK) affect one’s quality of life. Hence, it is imperative to investigate the underlying causes of these ocular surface disorders. During blink, the undersurface of the eyelid tends to interact with the cornea and the conjunctiva. The presence of a contact lens can add to the biomechanical frictional changes on these surfaces. To estimate these changes with and without a contact lens, a finite element model (FEM) of the eyelid wiper, eyeball, and contact lens was developed using COMSOL Multiphysics. Biomechanical properties such as von Mises stress (VMS) and displacement were calculated. Our study concluded that (a) maximum VMS was observed in the lid wiper in the absence of contact lens in the eye and (b) maximum VMS was observed in the superior 1.3 mm of the cornea in the presence of the contact lens in the eye. Thus, the development of friction-induced ocular surface disorders such as LWE, SLK, SEAL, and LSCD could be attributed to increased VMS. FEA is a useful simulation tool that helps us to understand the effect of blink on a normal eye with and without CL.
Collapse
|
6
|
Lievens CW, Rayborn E. Tribology and the Ocular Surface. Clin Ophthalmol 2022; 16:973-980. [PMID: 35386611 PMCID: PMC8977479 DOI: 10.2147/opth.s360293] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 03/24/2022] [Indexed: 11/23/2022] Open
Abstract
Introduction Tribology is known as the science of friction, lubrication and the determination of what occurs when two surfaces slide against one another. The required partners in this science are a minimum of two surfaces and relative motion. Tribology could be a key factor in dissecting the issues that surround and confound dry eye in patients as well as contact lens discomfort and intolerance. Specifically, it is this issue that is a potential causative underlying factor that could lead to conditions like lid wiper epitheliopathy (LWE). Methods Peer-reviewed literature was reviewed as It pertains to ocular tribology and the application to the ocular anatomy. A PubMed review was performed using the keywords: tribology, friction, lid wiper epitheliopathy, contact lens, and dry eye. All manuscripts were reviewed for mentions of tribology and friction. The exact same process was performed with The Association for Research in Vision and Ophthalmology (ARVO) abstracts. Results In relation to the ocular surface, tribology describes the mechanical interactions between the upper and lower lid wipers and the globe. The Stribeck curve can be applied, as the sliding partners are separated by a complex, lubricating tear film. The surface brush anatomy at the eye to eyelid juncture reduces friction and alters the Stribeck curve in favor of the hydrodynamic regime, allowing for high velocity movement with minimal wear. Changes to the tear film or the introduction of a contact lens can displace the Stribeck curve, increase friction, and induce wear thus leading to patient symptomology. Conclusion Further studies may provide new insight into contact lens discomfort and ocular surface disease, including LWE; however, adaptation of tribology work performed in vitro to in vivo patient care is challenging.
Collapse
Affiliation(s)
- Chris W Lievens
- Southern College of Optometry, Memphis, TN, USA
- Anglia Ruskin University, Cambridge, UK
| | | |
Collapse
|
7
|
Attrition und Osmokinetik – Zwei Konzepte zur Pathogenese des Trockenen Auges. SPEKTRUM DER AUGENHEILKUNDE 2021. [DOI: 10.1007/s00717-021-00505-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
ZusammenfassungDie neuen Erkenntnisse der Pathophysiolgie des Trockenen Auges erkennen das Zusammenspiel von Tränen, Augenoberfläche und Lidoberfläche als eine funktionelle Einheit an. Der Begriff der Benetzungsfähigkeit der Tränen in Abhängigkeit der mikrotektonischen Anatomie der Augenoberfläche relativiert die Anforderungen an Träne und Tränenersatzmittel. Das Model der Attrition, welches die Effekte der friktionsneutralisierenden Kapazität des Tränenfilms, der Reibung und die Bedeutung der Mechanotransduktionskapazität des Epithels zusammenfasst, wird eingeführt und dessen pathophysiologische Bedeutung erläutert. Attrition und Benetzung bestimmen zusammen grundlegende pathophysiologische Vorgänge in der Augenoberfläche wie Aktivierung von Nerven (subjektive Beschwerden) sowie Entzündung und beeinflussen damit die Dynamik der Pathophysiologie, und den Übergang von vorübergehenden Beschwerden zu einer manifesten Erkrankung des Trockenen Auges. Die Betrachtung der Osmolarität als numerischer statischer Grenzwert zur alleinigen Diagnose des Trockenen Auges ist klinisch nicht haltbar. Das neue, dynamische Model der Osmokinetik, zeigt dagegen eine Alternative auf, in der die Tageschwankungen und die Beachtung des durchschnittlichen Osmolaritätsniveaus gröβere Bedeutung gewinnen und damit der eigentlichen pathophysiologischen Bedeutung der Osmolarität gerechter wird.
Collapse
|
8
|
Anderson DM, Corsaro M, Horton J, Reid T, Seshaiyer P. Tear film dynamics with blinking and contact lens motion. MATHEMATICAL MEDICINE AND BIOLOGY-A JOURNAL OF THE IMA 2021; 38:355-395. [PMID: 34286343 DOI: 10.1093/imammb/dqab010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 05/17/2021] [Accepted: 06/28/2021] [Indexed: 11/13/2022]
Abstract
We develop a lubrication theory-based mathematical model that describes the dynamics of a tear film during blinking and contact lens (CL) wear. The model extends previous work on pre-corneal tear film dynamics during blinking by coupling the partial differential equation for tear film thickness to a dynamic model for CL motion. We explore different models for eyelid motion and also account for possible voluntary and involuntary globe (eyeball) rotation that may accompany blinking. Boundary conditions for mass flux at the eyelids are also adapted to account for the presence and motion of the CL. Our predictions for CL motion compare reasonably with existing data. Away from the eyelids the pre-lens tear film (PrLTF) is shifted, relative to its pre-corneal counterpart, in the direction of CL motion. Near the eyelids, the inflow/outflow of fluid under the eyelids also influences the PrLTF profile. We also compare our PrLTF dynamics to existing in vivo tear film thickness measurements.
Collapse
Affiliation(s)
- Daniel M Anderson
- Department of Mathematical Sciences, George Mason University, Fairfax, VA 22030, USA
| | - Maria Corsaro
- Department of Mathematics, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Jonathan Horton
- Department of Mathematical Sciences, George Mason University, Fairfax, VA 22030, USA
| | - Tim Reid
- Department of Mathematical Sciences, George Mason University, Fairfax, VA 22030, USA
| | - Padmanabhan Seshaiyer
- Department of Mathematical Sciences, George Mason University, Fairfax, VA 22030, USA
| |
Collapse
|
9
|
Doughty MJ. Morphological features of cells along Marx's line of the marginal conjunctiva of the human eyelid. Clin Exp Optom 2021; 96:76-84. [DOI: 10.1111/j.1444-0938.2012.00763.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2011] [Revised: 02/22/2012] [Accepted: 03/21/2012] [Indexed: 12/23/2022] Open
Affiliation(s)
- Michael J Doughty
- Department of Vision Sciences, Glasgow‐Caledonian University, Cowcaddens Road, Glasgow, Scotland,
| |
Collapse
|
10
|
Downie LE, Bandlitz S, Bergmanson JPG, Craig JP, Dutta D, Maldonado-Codina C, Ngo W, Siddireddy JS, Wolffsohn JS. CLEAR - Anatomy and physiology of the anterior eye. Cont Lens Anterior Eye 2021; 44:132-156. [PMID: 33775375 DOI: 10.1016/j.clae.2021.02.009] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 02/06/2023]
Abstract
A key element of contact lens practice involves clinical evaluation of anterior eye health, including the cornea and limbus, conjunctiva and sclera, eyelids and eyelashes, lacrimal system and tear film. This report reviews the fundamental anatomy and physiology of these structures, including the vascular supply, venous drainage, lymphatic drainage, sensory innervation, physiology and function. This is the foundation for considering the potential interactions with, and effects of, contact lens wear on the anterior eye. This information is not consistently published as academic research and this report provides a synthesis from all available sources. With respect to terminology, the report aims to promote the consistent use of nomenclature in the field, and generally adopts anatomical terms recommended by the Federative Committee for Anatomical Terminology. Techniques for the examination of the ocular surface are also discussed.
Collapse
Affiliation(s)
- Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Australia.
| | - Stefan Bandlitz
- Höhere Fachschule für Augenoptik Köln, Cologne School of Optometry, Germany; School of Optometry, Aston University, Birmingham, UK
| | - Jan P G Bergmanson
- Texas Eye Research and Technology Center, University of Houston College of Optometry, United States
| | - Jennifer P Craig
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Debarun Dutta
- School of Optometry, Aston University, Birmingham, UK
| | - Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, UK
| | - William Ngo
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 14W Hong Kong Science Park, Hong Kong
| | | | - James S Wolffsohn
- School of Optometry, Aston University, Birmingham, UK; Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand
| |
Collapse
|
11
|
Lee HP, Alisafaei F, Adebawale K, Chang J, Shenoy VB, Chaudhuri O. The nuclear piston activates mechanosensitive ion channels to generate cell migration paths in confining microenvironments. SCIENCE ADVANCES 2021; 7:7/2/eabd4058. [PMID: 33523987 PMCID: PMC7793582 DOI: 10.1126/sciadv.abd4058] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 11/18/2020] [Indexed: 05/24/2023]
Abstract
Cell migration in confining microenvironments is limited by the ability of the stiff nucleus to deform through pores when migration paths are preexisting and elastic, but how cells generate these paths remains unclear. Here, we reveal a mechanism by which the nucleus mechanically generates migration paths for mesenchymal stem cells (MSCs) in confining microenvironments. MSCs migrate robustly in nanoporous, confining hydrogels that are viscoelastic and plastic but not in hydrogels that are more elastic. To migrate, MSCs first extend thin protrusions that widen over time because of a nuclear piston, thus opening up a migration path in a confining matrix. Theoretical modeling and experiments indicate that the nucleus pushing into the protrusion activates mechanosensitive ion channels, leading to an influx of ions that increases osmotic pressure, which outcompetes hydrostatic pressure to drive protrusion expansion. Thus, instead of limiting migration, the nucleus powers migration by generating migration paths.
Collapse
Affiliation(s)
- Hong-Pyo Lee
- Department of Mechanical Engineering, Stanford University, Stanford, CA, USA
| | - Farid Alisafaei
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Kolade Adebawale
- Department of Chemical Engineering, Stanford University, Stanford, CA, USA
| | - Julie Chang
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Vivek B Shenoy
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Ovijit Chaudhuri
- Department of Mechanical Engineering, Stanford University, Stanford, CA, USA.
| |
Collapse
|
12
|
Allen Q, Raeymaekers B. Maximizing the Lubricant Film Thickness Between a Rigid Microtextured and a Smooth Deformable Surface in Relative Motion, Using a Soft Elasto-Hydrodynamic Lubrication Model. JOURNAL OF TRIBOLOGY 2020; 142:071802. [PMID: 34168394 PMCID: PMC8208301 DOI: 10.1115/1.4046291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/21/2020] [Accepted: 01/22/2020] [Indexed: 05/11/2023]
Abstract
We design a pattern of microtexture features to increase hydrodynamic pressure and lubricant film thickness in a hard-on-soft bearing. We use a soft elastohydrodynamic lubrication model to evaluate the effect of microtexture design parameters and bearing operating conditions on the resulting lubricant film thickness and find that the maximum lubricant film thickness occurs with a texture density between 10% and 40% and texture aspect ratio between 1% and 14%, depending on the bearing load and operating conditions. We show that these results are similar to those of hydrodynamic textured bearing problems because the lubricant film thickness is almost independent of the stiffness of the bearing surfaces in full-film lubrication.
Collapse
Affiliation(s)
- Quentin Allen
- Department of Mechanical Engineering, University of Utah, 1495 E. 100 S. (1550 MEK), Salt Lake City, UT 84112
| | - Bart Raeymaekers
- Department of Mechanical Engineering, University of Utah, 1495 E. 100 S. (1550 MEK), Salt Lake City, UT 84112
| |
Collapse
|
13
|
van Setten GB. Impact of Attrition, Intercellular Shear in Dry Eye Disease: When Cells are Challenged and Neurons are Triggered. Int J Mol Sci 2020; 21:E4333. [PMID: 32570730 PMCID: PMC7352662 DOI: 10.3390/ijms21124333] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 06/02/2020] [Accepted: 06/15/2020] [Indexed: 12/18/2022] Open
Abstract
The mechanical component in the pathophysiology of dry eye disease (DED) deserves attention as an important factor. The lubrication deficit induced impaired mechano-transduction of lid pressure to the ocular surfaces may lead to the dysregulation of homeostasis in the epithelium, with sensations of pain and secondary inflammation. Ocular pain is possibly the first sign of attrition and may occur in the absence of visible epithelial damage. Attrition is a process which involves the constant or repeated challenge of ocular surface tissues by mechanical shear forces; it is enhanced by the thinning of corneal epithelium in severe DED. As a highly dynamic process leading to pain and neurogenic inflammation, the identification of the impact of attrition and its potential pathogenic role could add a new perspective to the current more tear film-oriented models of ocular surface disease. Treatment of DED addressing lubrication deficiencies and inflammation should also consider the decrease of attrition in order to stimulate epithelial recovery and neural regeneration. The importance of hyaluronic acid, its molecular characteristics, the extracellular matrix and autoregulative mechanisms in this process is outlined. The identification of the attrition and recognition of its impact in dry eye pathophysiology could contribute to a better understanding of the disease and optimized treatment regimens.
Collapse
Affiliation(s)
- Gysbert-Botho van Setten
- Department of Clinical Neuroscience (CNS), Karolinska Institutet, 11282 Stockholm, Sweden; ; Tel.: +46-8-672-3298
- St Eriks Eye Hospital, 11282 Stockholm, Sweden
| |
Collapse
|
14
|
Moyle N, Wu H, Khripin C, Bremond F, Hui CY, Jagota A. Enhancement of elastohydrodynamic friction by elastic hysteresis in a periodic structure. SOFT MATTER 2020; 16:1627-1635. [PMID: 31960009 DOI: 10.1039/c9sm02087j] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Lubricated contacts are present in many engineering and biological systems involving soft solids. Typical mechanisms considered for controlling the sliding friction in such lubricated conditions involve bulk material compliance, fluid viscosity, viscoelastic response of the material (hysteretic friction), and breaking of the fluid film where dry contact occurs (adhesive friction). In this work we show that a two-phase periodic structure (TPPS), with a varying modulus across the sliding surface, provides significant enhancement of lubricated sliding friction when the system is in the elastohydrodynamic lubrication (EHL) regime. We propose that the enhanced friction is due to extra energy loss during periodic transitions of the sliding indenter between the compliant and stiff regions during which excess energy is dissipated through the fluid layer. This is a form of elastic hysteresis that provides a novel mechanism for friction enhancement in soft solids under lubricated conditions.
Collapse
Affiliation(s)
- Nichole Moyle
- Department of Chemical and Biomolecular Engineering, Lehigh University, Bethlehem, PA, USA.
| | | | | | | | | | | |
Collapse
|
15
|
Multiscale reverse engineering of the human ocular surface. Nat Med 2019; 25:1310-1318. [PMID: 31384041 DOI: 10.1038/s41591-019-0531-2] [Citation(s) in RCA: 77] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 06/21/2019] [Indexed: 02/07/2023]
Abstract
Here we present a miniaturized analog of a blinking human eye to reverse engineer the complexity of the interface between the ocular system and the external environment. Our model comprises human cells and provides unique capabilities to replicate multiscale structural organization, biological phenotypes and dynamically regulated environmental homeostasis of the human ocular surface. Using this biomimetic system, we discovered new biological effects of blink-induced mechanical forces. Furthermore, we developed a specialized in vitro model of evaporative dry-eye disease for high-content drug screening. This work advances our ability to emulate how human physiological systems interface with the external world, and may contribute to the future development of novel screening platforms for biopharmaceutical and environmental applications.
Collapse
|
16
|
Masterton S, Ahearne M. Mechanobiology of the corneal epithelium. Exp Eye Res 2018; 177:122-129. [PMID: 30086260 PMCID: PMC6280025 DOI: 10.1016/j.exer.2018.08.001] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 07/16/2018] [Accepted: 08/03/2018] [Indexed: 12/16/2022]
Abstract
There has been a drive to develop new cell based therapies to treat corneal blindness, one of the most common causes of blindness worldwide. Mechanical and physical cues are known to regulate the behavior of many cell types, however studies examining these effects on corneal epithelial cells have been limited in number and their findings have not previously been amalgamated and contrasted. Here, we provide an overview of the different types of mechanical stimuli to which the corneal epithelium is exposed and the influence that these have on the cells. Shear stress from the tear film motion and blinking, extracellular matrix stiffness and external physical forces such as eye rubbing and contact lens wear are among some of the forms of mechanical stimuli that the epithelium experiences. In vivo and in vitro studies examining the mechanobiology on corneal epithelial cells under differing mechanical environments are explored. A greater understanding of the mechanobiology of the corneal epithelium has the potential to lead to improved tissue engineering and cell based therapies to repair and regenerate damaged cornea.
Collapse
Affiliation(s)
- Sophia Masterton
- Dept of Mechanical and Manufacturing Engineering, School of Engineering, Trinity College Dublin, University of Dublin, Ireland; Trinity Centre for Bioengineering, Trinity Biomedical Science Institute, Trinity College Dublin, University of Dublin, Ireland
| | - Mark Ahearne
- Dept of Mechanical and Manufacturing Engineering, School of Engineering, Trinity College Dublin, University of Dublin, Ireland; Trinity Centre for Bioengineering, Trinity Biomedical Science Institute, Trinity College Dublin, University of Dublin, Ireland.
| |
Collapse
|
17
|
Korogiannaki M, Samsom M, Schmidt TA, Sheardown H. Surface-Functionalized Model Contact Lenses with a Bioinspired Proteoglycan 4 (PRG4)-Grafted Layer. ACS APPLIED MATERIALS & INTERFACES 2018; 10:30125-30136. [PMID: 30114356 DOI: 10.1021/acsami.8b09755] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Ocular dryness and discomfort are the primary reasons for the discontinuation of contact lens wear. This is mainly due to poorly hydrated contact lens surfaces and increased friction, particularly at the end of the day and can potentially cause reduced vision or even inflammation. Proteoglycan 4 (PRG4) is a mucinous glycoprotein with boundary lubricating properties, naturally found in the eye, able to prevent tear film evaporation and protect the ocular surface during blinking. Aiming to improve the interfacial interactions between the ocular surface and the contact lens, the synthesis and characterization of surface-modified model contact lenses with PRG4 is described. Full-length recombinant human PRG4 (rhPRG4) was successfully grafted onto the surface of model conventional and silicone hydrogel (SiHy) contact lenses via its somatomedin B-like end-domain using N, N'-carbonyldiimidazole linking chemistry. Grafting was assessed by Fourier transform infrared spectroscopy-attenuated total reflectance, X-ray photoelectron spectroscopy, and radioactive (I131) labeling. Surface immobilization of rhPRG4 led to model conventional and SiHy materials with improved antifouling properties, without impacting optical transparency or causing any toxic effects to human corneal epithelial cells in vitro. The surface wettability and the boundary friction against human corneal tissue were found to be substrate-dependent, with only the rhPRG4-grafted model SiHy exhibiting a reduced contact angle and kinetic friction coefficient compared to the unmodified surfaces. Hence, clinical grade rhPRG4 can be an attractive candidate for the development of novel bioinspired SiHy contact lenses, providing improved comfort and overall lens performance.
Collapse
Affiliation(s)
- Myrto Korogiannaki
- Department of Chemical Engineering , McMaster University , Hamilton , Ontario L8S 4L7 , Canada
| | - Michael Samsom
- Biomedical Engineering Graduate Program , University of Calgary , Calgary , Alberta T2N 1N4 , Canada
| | - Tannin A Schmidt
- Biomedical Engineering Graduate Program , University of Calgary , Calgary , Alberta T2N 1N4 , Canada
| | - Heather Sheardown
- Department of Chemical Engineering , McMaster University , Hamilton , Ontario L8S 4L7 , Canada
| |
Collapse
|
18
|
Naik KG, Chakraborty S, Chakraborty J. Finite size effects of ionic species sensitively determine load bearing capacities of lubricated systems under combined influence of electrokinetics and surface compliance. SOFT MATTER 2017; 13:6422-6429. [PMID: 28876023 DOI: 10.1039/c7sm01423f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The behaviour and health of lubricated systems in various natural and artificial settings are often characterized by their load bearing capacity. This capacity stemming from the lift force associated with confined fluid flow can be significantly altered due to surface compliance and electrokinetic effects. Here, we highlight the influence of finite size of the ionic species participating in electrokinetic transport with substrate compliance in determining the electromechanical characteristics of lubricated systems. With these new considerations, anomalous trends previously observed for the load bearing capacity corresponding to high values of zeta potential are corrected. Simultaneously, trends associated with the finite ionic size are also found to be reversed, but fall in line with the consistent theory. Importantly, despite an intricate interplay among the various influences - electrokinetic, hydrodynamic, geometric, and elastic - previously established trends due to geometric (non-parallel slider geometry) and elastic effects are found to persist. Specifically, in the presence of electrokinetic effects, an increase in the obliqueness of the slider geometry results in lower values of load bearing capacity while an increase in the stiffness leads to higher values. These results point to a certain robustness in the overall theory and it is hoped that they can contribute to better practical designs of slider bearings and an improved understanding of lubricated sliding surfaces in biological settings.
Collapse
Affiliation(s)
- Kaustubh Girish Naik
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, West Bengal - 721302, India.
| | | | | |
Collapse
|
19
|
Bron AJ, de Paiva CS, Chauhan SK, Bonini S, Gabison EE, Jain S, Knop E, Markoulli M, Ogawa Y, Perez V, Uchino Y, Yokoi N, Zoukhri D, Sullivan DA. TFOS DEWS II pathophysiology report. Ocul Surf 2017; 15:438-510. [PMID: 28736340 DOI: 10.1016/j.jtos.2017.05.011] [Citation(s) in RCA: 1001] [Impact Index Per Article: 143.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Accepted: 05/26/2017] [Indexed: 12/18/2022]
Abstract
The TFOS DEWS II Pathophysiology Subcommittee reviewed the mechanisms involved in the initiation and perpetuation of dry eye disease. Its central mechanism is evaporative water loss leading to hyperosmolar tissue damage. Research in human disease and in animal models has shown that this, either directly or by inducing inflammation, causes a loss of both epithelial and goblet cells. The consequent decrease in surface wettability leads to early tear film breakup and amplifies hyperosmolarity via a Vicious Circle. Pain in dry eye is caused by tear hyperosmolarity, loss of lubrication, inflammatory mediators and neurosensory factors, while visual symptoms arise from tear and ocular surface irregularity. Increased friction targets damage to the lids and ocular surface, resulting in characteristic punctate epithelial keratitis, superior limbic keratoconjunctivitis, filamentary keratitis, lid parallel conjunctival folds, and lid wiper epitheliopathy. Hybrid dry eye disease, with features of both aqueous deficiency and increased evaporation, is common and efforts should be made to determine the relative contribution of each form to the total picture. To this end, practical methods are needed to measure tear evaporation in the clinic, and similarly, methods are needed to measure osmolarity at the tissue level across the ocular surface, to better determine the severity of dry eye. Areas for future research include the role of genetic mechanisms in non-Sjögren syndrome dry eye, the targeting of the terminal duct in meibomian gland disease and the influence of gaze dynamics and the closed eye state on tear stability and ocular surface inflammation.
Collapse
Affiliation(s)
- Anthony J Bron
- Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK; Vision and Eye Research Unit, Anglia Ruskin University, Cambridge, UK.
| | - Cintia S de Paiva
- Department of Ophthalmology, Baylor College of Medicine, Houston, TX, USA
| | - Sunil K Chauhan
- Schepens Eye Research Institute & Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| | - Stefano Bonini
- Department of Ophthalmology, University Campus Biomedico, Rome, Italy
| | - Eric E Gabison
- Department of Ophthalmology, Fondation Ophtalmologique Rothschild & Hôpital Bichat Claude Bernard, Paris, France
| | - Sandeep Jain
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL, USA
| | - Erich Knop
- Departments of Cell and Neurobiology and Ocular Surface Center Berlin, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Maria Markoulli
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Yoko Ogawa
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Victor Perez
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
| | - Yuichi Uchino
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Driss Zoukhri
- Tufts University School of Dental Medicine, Boston, MA, USA
| | - David A Sullivan
- Schepens Eye Research Institute & Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
20
|
Molladavoodi S, Robichaud M, Wulff D, Gorbet M. Corneal epithelial cells exposed to shear stress show altered cytoskeleton and migratory behaviour. PLoS One 2017; 12:e0178981. [PMID: 28662184 PMCID: PMC5491001 DOI: 10.1371/journal.pone.0178981] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Accepted: 05/22/2017] [Indexed: 12/22/2022] Open
Abstract
Cells that form the corneal epithelium, the outermost layer of the cornea, are exposed to shear stress through blinking during waking hours. In this in vitro study, the effect of fluid shear stress on human corneal epithelial cells (HCECs) was investigated. Following exposure to shear stresses of 4 and 8 dyn/cm2, HCECs showed cytoskeletal rearrangement with more prominent, organized and elongated filamentous actin. Cytoskeletal changes were time-dependent, and were most significant after 24 hours of shear stress. Higher rates of migration and proliferation, as evaluated by a scratch assay, were also observed following 24 hours of low shear stress exposure (4 dyn/cm2). This result contrasted the poor migration observed in samples scratched before shear exposure, indicating that shear-induced cytoskeletal changes played a key role in improved wound healing and must therefore precede any damage to the cell layer. HCEC cytoskeletal changes were accompanied by an upregulation in integrin β1 and downregulation of ICAM-1. These results demonstrate that HCECs respond favourably to flow-induced shear stress, impacting their proliferation and migration properties as well as phenotype.
Collapse
Affiliation(s)
- Sara Molladavoodi
- Department of System Design Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Matthew Robichaud
- Department of System Design Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - David Wulff
- Department of Chemical Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Maud Gorbet
- Department of System Design Engineering, University of Waterloo, Waterloo, Ontario, Canada
- * E-mail:
| |
Collapse
|
21
|
Fluid Penetration in a Deformable Permeable Web Moving Past a Stationary Rigid Solid Cylinder. Transp Porous Media 2016. [DOI: 10.1007/s11242-016-0780-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
22
|
Efron N, Brennan NA, Morgan PB, Wilson T. Lid wiper epitheliopathy. Prog Retin Eye Res 2016; 53:140-174. [PMID: 27094372 DOI: 10.1016/j.preteyeres.2016.04.004] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 04/05/2016] [Accepted: 04/12/2016] [Indexed: 01/12/2023]
Abstract
Some recent research has resulted in a hypothesis that there is a common 'lid wiper' region that is apposite to the ocular surface or anterior lens surface (where contact lenses are worn), responsible for spreading tears during blinking. In the upper eyelid, it extends about 0.6 mm from the crest of the sharp posterior (inner) lid border (i.e. the mucocutaneous junction, or line of Marx) to the subtarsal fold superiorly and from the medial upper punctum to the lateral canthus horizontally. Histologically, it is seen as an epithelial elevation comprising of stratified epithelium with a transitional conjunctival structure of (moving posteriorly) squamous cells then cuboidal cells, with some parakeratinised cells and goblet cells. Lid wiper epitheliopathy (LWE) denotes staining of the lid wiper observed after instillation of dyes such as fluorescein, rose bengal or lissamine green. There have been some reports of higher rates of LWE in dry eye patients and contact lens wearers, but others have failed to find such associations. The primary cause of LWE is thought to be increased friction between the lid wiper and ocular or anterior contact lens surface due to inadequate lubrication, which could be caused by dry eye and may be exacerbated by factors such as abnormal blinking patterns, poor contact lens surface lubricity and adverse environmental influences. Recent evidence suggests that LWE is associated with sub-clinical inflammation. LWE has the potential to provide the missing mechanistic link between clinical observation and symptoms associated with dry eye and contact lens wear. Clinical and fundamental research into LWE is still in its infancy and in many instances equivocal; however, it is an idea that provides a potentially important new avenue for further investigation of anterior eye discomfort associated with ocular dryness and contact lens wear.
Collapse
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, Queensland 4059, Australia.
| | - Noel A Brennan
- Johnson & Johnson Vision Care, Inc., 7500 Centurion Parkway, Jacksonville, FL 32256, USA
| | - Philip B Morgan
- Eurolens Research, The University of Manchester, Dover Street, Manchester, M13 9PL, UK
| | - Tawnya Wilson
- Johnson & Johnson Vision Care, Inc., 7500 Centurion Parkway, Jacksonville, FL 32256, USA
| |
Collapse
|
23
|
Xu X, Al-Ghabeish M, Rahman Z, Krishnaiah YSR, Yerlikaya F, Yang Y, Manda P, Hunt RL, Khan MA. Formulation and process factors influencing product quality and in vitro performance of ophthalmic ointments. Int J Pharm 2015; 493:412-25. [PMID: 26231106 DOI: 10.1016/j.ijpharm.2015.07.066] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Revised: 07/20/2015] [Accepted: 07/26/2015] [Indexed: 01/04/2023]
Abstract
Owing to its unique anatomical and physiological functions, ocular surface presents special challenges for both design and performance evaluation of the ophthalmic ointment drug products formulated with a variety of bases. The current investigation was carried out to understand and identify the appropriate in vitro methods suitable for quality and performance evaluation of ophthalmic ointment, and to study the effect of formulation and process variables on its critical quality attributes (CQA). The evaluated critical formulation variables include API initial size, drug percentage, and mineral oil percentage while the critical process parameters include mixing rate, temperature, time and cooling rate. The investigated quality and performance attributes include drug assay, content uniformity, API particle size in ointment, rheological characteristics, in vitro drug release and in vitro transcorneal drug permeation. Using design of experiments (DoE) as well as a novel principle component analysis approach, five of the quality and performance attributes (API particle size, storage modulus of ointment, high shear viscosity of ointment, in vitro drug release constant and in vitro transcorneal drug permeation rate constant) were found to be highly influenced by the formulation, in particular the strength of API, and to a lesser degree by processing variables. Correlating the ocular physiology with the physicochemical characteristics of acyclovir ophthalmic ointment suggested that in vitro quality metrics could be a valuable predictor of its in vivo performance.
Collapse
Affiliation(s)
- Xiaoming Xu
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Manar Al-Ghabeish
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Ziyaur Rahman
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Yellela S R Krishnaiah
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Firat Yerlikaya
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Yang Yang
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Prashanth Manda
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Robert L Hunt
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Mansoor A Khan
- Food and Drug Administration, CDER/OPQ/OTR/DPQR, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.
| |
Collapse
|
24
|
Spontaneous Blinking from a Tribological Viewpoint. Ocul Surf 2015; 13:236-49. [DOI: 10.1016/j.jtos.2014.12.004] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Revised: 12/27/2014] [Accepted: 12/01/2014] [Indexed: 11/24/2022]
|
25
|
Mathematical model of microbicidal flow dynamics and optimization of rheological properties for intra-vaginal drug delivery: Role of tissue mechanics and fluid rheology. J Biomech 2015; 48:1625-30. [DOI: 10.1016/j.jbiomech.2015.01.049] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Accepted: 01/29/2015] [Indexed: 11/21/2022]
|
26
|
Pult H, Korb DR, Murphy PJ, Riede-Pult BH, Blackie C. A new model of central lid margin apposition and tear film mixing in spontaneous blinking. Cont Lens Anterior Eye 2015; 38:173-80. [DOI: 10.1016/j.clae.2015.01.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 01/21/2015] [Accepted: 01/26/2015] [Indexed: 11/17/2022]
|
27
|
Tavazzi S, Ferraro L, Cozza F, Pastori V, Lecchi M, Farris S, Borghesi A. Hydrogen peroxide mechanosynthesis in siloxane-hydrogel contact lenses. ACS APPLIED MATERIALS & INTERFACES 2014; 6:19606-19612. [PMID: 25356999 DOI: 10.1021/am503940p] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Drug-loaded contact lenses are emerging as the preferred treatment method for several ocular diseases, and efforts are being directed to promote extended and controlled delivery. One strategy is based on delivery induced by environmental triggers. One of these triggers can be hydrogen peroxide, since many platforms based on drug-loaded nanoparticles were demonstrated to be hydrogen-peroxide responsive. This is particularly interesting when hydrogen peroxide is the result of a specific pathophysiological condition. Otherwise, an alternative route to induce drug delivery is here proposed, namely the mechano-synthesis. The present work represents the proof-of-concept of the mechanosynthesis of hydrogen peroxide in siloxane-hydrogel contact lenses as a consequence of the cleavage of siloxane bonds at the interface between the polymer and water in aqueous phase. Their spongy morphology makes contact lenses promising systems for mechanical-to-chemical energy conversion, since the amount of hydrogen peroxide is expected to scale with the interfacial area between the polymer and water. The eyelid pressure during wear is sufficient to induce the hydrogen peroxide synthesis with concentrations which are biocompatible and suitable to trigger the drug release through hydrogen-peroxide-responsive platforms. For possible delivery on demand, the integration of piezoelectric polymers in the siloxane-hydrogel contact lenses could be designed, whose mechanical deformation could be induced by an applied wireless-controlled voltage.
Collapse
Affiliation(s)
- Silvia Tavazzi
- Materials Science Department, University of Milano Bicocca , Via Cozzi 55, I-20125 Milan, Italy
| | | | | | | | | | | | | |
Collapse
|
28
|
Kang YG, Shin JW, Park SH, Oh MJ, Park HS, Shin JW, Kim SH. Effects of flow-induced shear stress on limbal epithelial stem cell growth and enrichment. PLoS One 2014; 9:e93023. [PMID: 24658122 PMCID: PMC3962472 DOI: 10.1371/journal.pone.0093023] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2014] [Accepted: 02/27/2014] [Indexed: 12/13/2022] Open
Abstract
The roles of limbal epithelial stem cells (LESCs) are widely recognized, but for these cells to be utilized in basic research and potential clinical applications, researchers must be able to efficiently isolate them and subsequently maintain their stemness in vitro. We aimed to develop a biomimetic environment for LESCs involving cells from their in vivo niche and the principle of flow-induced shear stress, and to subsequently demonstrate the potential of this novel paradigm. LESCs, together with neighboring cells, were isolated from the minced limbal tissues of rabbits. At days 8 and 9 of culture, the cells were exposed to a steady flow or intermittent flow for 2 h per day in a custom-designed bioreactor. The responses of LESCs and epithelial cells were assessed at days 12 and 14. LESCs and epithelial cells responded to both types of flow. Proliferation of LESCs, as assessed using a BrdU assay, was increased to a greater extent under steady flow conditions. Holoclones were found under intermittent flow, indicating that differentiation into transient amplifying cells had occurred. Immunofluorescent staining of Bmi-1 suggested that steady flow has a positive effect on the maintenance of stemness. This finding was confirmed by real-time PCR. Notch-1 and p63 were more sensitive to intermittent flow, but this effect was transient. K3 and K12 expression, indicative of differentiation of LESCs into epithelial cells, was induced by flow and lasted longer under intermittent flow conditions. In summary, culture of LESCs in a bioreactor under a steady flow paradigm, rather than one of intermittent flow, is beneficial for both increasing proliferation and maintaining stemness. Conversely, intermittent flow appears to induce differentiation of LESCs. This novel experimental method introduces micro-mechanical stimuli to traditional culture techniques, and has potential for regulating the proliferation and differentiation of LESCs in vitro, thereby facilitating research in this field.
Collapse
Affiliation(s)
- Yun Gyeong Kang
- Department of Biomedical Engineering, Inje University, Gyeongnam, Korea
| | - Ji Won Shin
- Cardiovascular and Metabolic Disease Center, Inje University, Busan, Korea
| | - So Hee Park
- Department of Biomedical Engineering, Inje University, Gyeongnam, Korea
| | - Min-Jae Oh
- Department of Biomedical Engineering, Inje University, Gyeongnam, Korea
| | | | - Jung-Woog Shin
- Department of Biomedical Engineering, Inje University, Gyeongnam, Korea
- Cardiovascular and Metabolic Disease Center, Inje University, Busan, Korea
- Department of Health Science and Technology/Institute of Aged Life Redesign/UHRC, Inje University, Gyeongnam, Korea
- * E-mail: (J-WS); (S-HK)
| | - Su-Hyang Kim
- Department of Biomedical Engineering, Inje University, Gyeongnam, Korea
- * E-mail: (J-WS); (S-HK)
| |
Collapse
|
29
|
Abstract
PURPOSE Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. MATERIALS AND METHODS Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. RESULTS Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). CONCLUSIONS The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.
Collapse
Affiliation(s)
- Colin F Cerretani
- Department of Chemical and Biomolecular Engineering, University of California , Berkeley, CA , USA and
| | | |
Collapse
|
30
|
Schmidt TA, Sullivan DA, Knop E, Richards SM, Knop N, Liu S, Sahin A, Darabad RR, Morrison S, Kam WR, Sullivan BD. Transcription, translation, and function of lubricin, a boundary lubricant, at the ocular surface. JAMA Ophthalmol 2013; 131:766-76. [PMID: 23599181 DOI: 10.1001/jamaophthalmol.2013.2385] [Citation(s) in RCA: 93] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
IMPORTANCE Lubricin may be an important barrier to the development of corneal and conjunctival epitheliopathies that may occur in dry eye disease and contact lens wear. OBJECTIVE To test the hypotheses that lubricin (ie, proteoglycan 4 [PRG4 ]), a boundary lubricant, is produced by ocular surface epithelia and acts to protect the cornea and conjunctiva against significant shear forces generated during an eyelid blink and that lubricin deficiency increases shear stress on the ocular surface and promotes corneal damage. DESIGN, SETTING, AND PARTICIPANTS Human, porcine, and mouse tissues and cells were processed for molecular biological, immunohistochemical, and tribological studies, and wild-type and PRG4 knockout mice were evaluated for corneal damage. RESULTS Our findings demonstrate that lubricin is transcribed and translated by corneal and conjunctival epithelial cells. Lubricin messenger RNA is also present in lacrimal and meibomian glands, as well as in a number of other tissues. Absence of lubricin in PRG4 knockout mice is associated with a significant increase in corneal fluorescein staining. Our studies also show that lubricin functions as an effective friction-lowering boundary lubricant at the human cornea-eyelid interface. This effect is specific and cannot be duplicated by the use of hyaluronate or bovine serum albumin solutions. CONCLUSIONS AND RELEVANCE Our results show that lubricin is transcribed, translated, and expressed by ocular surface epithelia. Moreover, our findings demonstrate that lubricin presence significantly reduces friction between the cornea and conjunctiva and that lubricin deficiency may play a role in promoting corneal damage.
Collapse
Affiliation(s)
- Tannin A Schmidt
- Faculty of Kinesiology, Human Performance Laboratory Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
|
32
|
Ling JD, Gire A, Pflugfelder SC. PROSE therapy used to minimize corneal trauma in patients with corneal epithelial defects. Am J Ophthalmol 2013; 155:615-619, 619.e1-2. [PMID: 23218704 DOI: 10.1016/j.ajo.2012.09.033] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Revised: 09/22/2012] [Accepted: 09/25/2012] [Indexed: 11/28/2022]
Abstract
PURPOSE To review the effectiveness of continuous or extended daily wear of Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) for treating recurrent or persistent corneal epithelial defects from a variety of causes that were refractory to conventional therapy in 9 patients. DESIGN Retrospective case series. METHODS The medical records of 9 patients with a history of recurrent or persistent corneal epithelial defects resistant to conventional medical treatment who received treatment at the Cullen Eye Institute between January 2011 and July 2012 were reviewed. Demographic information, etiology, prior treatment, and outcome of PROSE treatment were analyzed. Recurrence after cessation of PROSE and complications were also identified. RESULTS The etiologies of recurrent or persistent corneal epithelial defects in this series included neurotrophic keratopathy, lattice and Avellino dystrophy, Stevens-Johnson syndrome, and chemical/thermal injury. All patients were initially treated with bandage contact lens; however, continuous silicone hydrogel lens wear was not effective in preventing recurrence or healing corneal epithelial defects in all patients. Epithelial defects healed without recurrence in all 9 patients treated with PROSE. Eight patients developed recurrent epithelial defects when PROSE was discontinued, but rehealed after resuming PROSE. Visual acuity improved in 8 patients (88.9%) treated with PROSE. CONCLUSIONS Complex persistent or recurrent corneal epithelial defects that failed to heal with extended silicone hydrogel contact lenses healed with PROSE. PROSE therapy was well tolerated, but corneal epithelial defects recurred in all but 1 case following cessation of therapy.
Collapse
Affiliation(s)
- Jeanie D Ling
- Cullen Eye Institute, Baylor College of Medicine, Houston, Texas 77030, USA
| | | | | |
Collapse
|
33
|
Abstract
It is now forty six years since the separate topics of friction, lubrication, wear and bearing design were integrated under the title 'Tribology' [Department of Education and Science, Lubrication (Tribology) Education and Research. A Report on the Present Position and Industry's Needs, HMSO, London, 1966]. Significant developments have been reported in many established and new aspects of tribology during this period. The subject has contributed to improved performance of much familiar equipment, such as reciprocating engines, where there have been vast improvements in engine reliability and efficiency. Nano-tribology has been central to remarkable advances in information processing and digital equipment. Shortly after widespread introduction of the term tribology, integration with biology and medicine prompted rapid and extensive interest in the fascinating sub-field now known as Bio-tribology [D. Dowson and V. Wright, Bio-tribology, in The Rheology of Lubricants, ed. T. C. Davenport, Applied Science Publishers, Barking, 1973, pp. 81-88]. An outline will be given of some of the developments in the latter field.
Collapse
Affiliation(s)
- Duncan Dowson
- School of Mechanical Engineering, The University of Leeds, Leeds, LS2 9JT, UK.
| |
Collapse
|
34
|
Angelini TE, Dunn AC, Urueña JM, Dickrell DJ, Burris DL, Sawyer WG. Cell friction. Faraday Discuss 2013; 156:31-9; discussion 87-103. [PMID: 23285620 DOI: 10.1039/c2fd00130f] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Cells sense and respond to their environment. Mechanotransduction is the process by which mechanical forces, stress, and strains are converted into biochemical signals that control cell behavior. In recent decades it has been shown that appropriate mechanical signals are essential to tissue health, but the role of friction and direct contact shearing across cell surfaces has been essentially unexplored. This, despite the obvious existence of numerous biological tissues whose express function depends on sliding contacts. In our studies on frictional interactions of corneal cells we find that the friction coefficients are on the order of mu = 0.03-0.06 for in vitro and in vivo experiments. Additionally, we observe cell death after single cycles of sliding at contact pressures estimated to be approximately 12 kPa. These experimental results suggest that frictional contact forces produce mechanical stresses and strains that are in the cellular mechanosensing ranges.
Collapse
Affiliation(s)
- T E Angelini
- Dept. of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611, USA
| | | | | | | | | | | |
Collapse
|
35
|
The Lid Wiper Contains Goblet Cells and Goblet Cell Crypts for Ocular Surface Lubrication During the Blink. Cornea 2012; 31:668-79. [DOI: 10.1097/ico.0b013e31823f8d8c] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
36
|
Dose-dependent and synergistic effects of proteoglycan 4 on boundary lubrication at a human cornea-polydimethylsiloxane biointerface. Eye Contact Lens 2012; 38:27-35. [PMID: 22157393 DOI: 10.1097/icl.0b013e31823f7041] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Proteoglycan 4 (PRG4), also known as lubricin, is a boundary lubricating mucin-like glycoprotein present on several tissue surfaces in the body. The objectives of this study were to (1) implement and characterize an in vitro boundary lubrication test at a human cornea-polydimethylsiloxane (PDMS) biointerface and (2) determine the dose-dependent and synergistic effects of PRG4, with hyaluronan (HA), on ocular surface boundary lubrication using this test. METHODS Human corneas and model PDMS material were articulated against each other, at effective sliding velocities v(eff) between 0.3 and 30 mm/sec under physiologic loads of approximately 8 to 25 kPa. Samples were tested serially in (1) saline, PRG4 at 30, 100, 300 μg/mL resuspended in saline, then saline again or (2) saline, AQuify Comfort Eye Drops (containing 0.1% HA), 300 μg/mL PRG4 in saline, 300 μg/mL PRG4 in AQuify, then saline again. Both static and kinetic friction coefficients were calculated. RESULTS PRG4 effectively lowered friction at the cornea-PDMS biointerface, both alone in a dose-dependent manner and in combination with HA. PRG4 reduced kinetic friction coefficients, <μ(kinetic, Neq)>, from approximately 0.30 in saline, to approximately 0.30, 0.24, and 0.17 in 30, 100, and 300 μg/mL PRG4, respectively. Values of <μ(kinetic, Neq)> in AQuify, approximately 0.32, were similar to those in saline; however, when combined with 300 μg/mL PRG4, values of <μ(kinetic, Neq)> were reduced to approximately 0.15. CONCLUSIONS PRG4 functions as an effective ocular surface boundary lubricant, both alone in a dose-dependent manner and in combination with HA.
Collapse
|
37
|
Tasoglu S, Park SC, Peters JJ, Katz DF, Szeri AJ. The consequences of yield stress on deployment of a non-Newtonian anti-HIV microbicide gel. JOURNAL OF NON-NEWTONIAN FLUID MECHANICS 2011; 166:1116-1122. [PMID: 22563138 PMCID: PMC3342340 DOI: 10.1016/j.jnnfm.2011.06.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
A recent study in South Africa has confirmed, for the first time, that a vaginal gel formulation of the antiretroviral drug Tenofovir, when applied topically, significantly inhibits sexual HIV transmission to women [10]. However the gel for this drug, and anti-HIV microbicide gels in general, have not been designed using full understanding of how gel spreading and retention in the vagina govern successful drug delivery. Elastohydrodynamic lubrication theory can be applied to model such spreading of microbicide gels, which are inherently non-Newtonian [13,15]. A yield stress is emerging as one of the important properties of microbicide gel vehicle deployment, as this may improve retention within the vaginal canal. On the other hand, a yield stress may decrease the initial extent of the coating flow. Here, we first explain a certain yield stress paradox observed generally in many lubrication flows. Four conditions are determined, via scaling analysis, which mitigate the inconsistency in the use of lubrication theory to analyze the specific problem of elastic wall squeezing flow of yield stress fluid. Parameters characterizing these conditions are obtained experimentally for a test gel. Using them, it is shown that the lubrication approximation may be applied to the elastic wall-squeezing problem for this gel.
Collapse
Affiliation(s)
- Savas Tasoglu
- Department of Mechanical Engineering, University of California, Berkeley, CA 94720-1740, USA
| | - Su Chan Park
- Department of Mechanical Engineering, University of California, Berkeley, CA 94720-1740, USA
| | - Jennifer J. Peters
- Department of Biomedical Engineering, Duke University, Box 90281, Durham, NC 22708, USA
- Department of Obstetrics and Gynecology, Duke University, Box 90281, Durham, NC 22708, USA
| | - David F. Katz
- Department of Biomedical Engineering, Duke University, Box 90281, Durham, NC 22708, USA
- Department of Obstetrics and Gynecology, Duke University, Box 90281, Durham, NC 22708, USA
| | - Andrew J. Szeri
- Department of Mechanical Engineering, University of California, Berkeley, CA 94720-1740, USA
| |
Collapse
|
38
|
Tasoglu S, Peters JJ, Park SC, Verguet S, Katz DF, Szeri AJ. The effects of inhomogeneous boundary dilution on the coating flow of an anti-HIV microbicide vehicle. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2011; 23:93101-931019. [PMID: 21998495 PMCID: PMC3189968 DOI: 10.1063/1.3633337] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2010] [Accepted: 08/09/2011] [Indexed: 05/27/2023]
Abstract
A recent study in South Africa has confirmed, for the first time, that a vaginal gel formulation of the antiretroviral drug Tenofovir, when topically applied, significantly inhibits sexual HIV transmission to women [Karim et al., Science 329, 1168 (2010)]. However, the gel for this drug and anti-HIV microbicide gels in general have not been designed using an understanding of how gel spreading and retention in the vagina govern successful drug delivery. Elastohydrodynamic lubrication theory can be applied to model spreading of microbicide gels [Szeri et al., Phys. Fluids 20, 083101 (2008)]. This should incorporate the full rheological behavior of a gel, including how rheological properties change due to contact with, and dilution by, ambient vaginal fluids. Here, we extend our initial analysis, incorporating the effects of gel dilution due to contact with vaginal fluid produced at the gel-tissue interface. Our original model is supplemented with a convective-diffusive transport equation to characterize water transport into the gel and, thus, local gel dilution. The problem is solved using a multi-step scheme in a moving domain. The association between local dilution of gel and rheological properties is obtained experimentally, delineating the way constitutive parameters of a shear-thinning gel are modified by dilution. Results show that dilution accelerates the coating flow by creating a slippery region near the vaginal wall akin to a dilution boundary layer, especially if the boundary flux exceeds a certain value. On the other hand, if the diffusion coefficient of boundary fluid is increased, the slippery region diminishes in extent and the overall rate of gel spreading decreases.
Collapse
|
39
|
Knop E, Knop N, Zhivov A, Kraak R, Korb DR, Blackie C, Greiner JV, Guthoff R. The lid wiper and muco-cutaneous junction anatomy of the human eyelid margins: an in vivo confocal and histological study. J Anat 2011; 218:449-61. [PMID: 21413985 DOI: 10.1111/j.1469-7580.2011.01355.x] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The inner border of the eyelid margin is critically important for ocular surface integrity because it guarantees the thin spread of the tear film. Its exact morphology in the human is still insufficiently known. The histology in serial sections of upper and lower lid margins in whole-mount specimens from 10 human body donors was compared to in vivo confocal microscopy of eight eyes with a Heidelberg retina-tomograph (HRT II) and attached Rostock cornea module. Behind the posterior margin of the Meibomian orifices, the cornified epidermis stopped abruptly and was replaced by a continuous layer of para-keratinized (pk) cells followed by discontinuous pk cells. The pk cells covered the muco-cutaneous junction (MCJ), the surface of which corresponded to the line of Marx (0.2-0.3 mm wide). Then a stratified epithelium with a conjunctival structure of cuboidal cells, some pk cells, and goblet cells formed an epithelial elevation of typically about 100 μm initial thickness (lid wiper). This continued for 0.3-1.5 mm and formed a slope. The MCJ and lid wiper extended all along the lid margin from nasal to temporal positions in the upper and lower lids. Details of the epithelium and connective tissue were also detectable using the Rostock cornea module. The human inner lid border has distinct zones. Due to its location and morphology, the epithelial lip of the lid wiper appears a suitable structure to spread the tear film and is distinct from the MCJ/line of Marx. Better knowledge of the lid margin appears important for understanding dry eye disease and its morphology can be analysed clinically by in vivo confocal microscopy.
Collapse
Affiliation(s)
- Erich Knop
- Ocular Surface Center Berlin, Department for Cell and Neurobiology, Center for Anatomy, Charité- Universitätsmedizin Berlin, Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
40
|
|
41
|
|
42
|
|
43
|
|
44
|
Szeri AJ, Park SC, Verguet S, Weiss A, Katz DF. A model of transluminal flow of an anti-HIV microbicide vehicle: Combined elastic squeezing and gravitational sliding. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2008; 20:83101. [PMID: 19547722 PMCID: PMC2698280 DOI: 10.1063/1.2973188] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2008] [Accepted: 07/08/2008] [Indexed: 05/27/2023]
Abstract
ELASTOHYDRODYNAMIC LUBRICATION OVER SOFT SUBSTRATES IS OF IMPORTANCE IN A NUMBER OF BIOMEDICAL PROBLEMS: From lubrication of the eye surface by the tear film, to lubrication of joints by synovial fluid, to lubrication between the pleural surfaces that protect the lungs and other organs. Such flows are also important for the drug delivery functions of vehicles for anti-HIV topical microbicides. These are intended to inhibit transmission into vulnerable mucosa, e.g., in the vagina. First generation prototype microbicides have gel vehicles, which spread after insertion and coat luminal surfaces. Effectiveness derives from potency of the active ingredients and completeness and durability of coating. Delivery vehicle rheology, luminal biomechanical properties, and the force due to gravity influence the coating mechanics. We develop a framework for understanding the relative importance of boundary squeezing and body forces on the extent and speed of the coating that results. A single dimensionless number, independent of viscosity, characterizes the relative influences of squeezing and gravitational acceleration on the shape of spreading in the Newtonian case. A second scale, involving viscosity, determines the spreading rate. In the case of a shear-thinning fluid, the Carreau number also plays a role. Numerical solutions were developed for a range of the dimensionless parameter and compared well with asymptotic theory in the limited case where such results can be obtained. Results were interpreted with respect to trade-offs between wall elasticity, longitudinal forces, bolus viscosity, and bolus volume. These provide initial insights of practical value for formulators of gel delivery vehicles for anti-HIV microbicidal formulations.
Collapse
|
45
|
A New Look at Lubrication of the Ocular Surface: Fluid Mechanics Behind the Blinking Eyelids. Ocul Surf 2008; 6:79-86. [DOI: 10.1016/s1542-0124(12)70271-9] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|