1
|
Abstract
Pelvic discontinuity (PD) has been a considerable challenge for the hip revision arthroplasty surgeon. However, not all PDs are the same. Some occur during primary cup insertion, resembling a fresh periprosthetic fracture that separates the superior and inferior portions of the pelvis, while others are chronic as a result of gradual acetabular bone loss due to osteolysis and/or acetabular implant loosening. In the past, ORIF, various types of cages, bone grafts and bone cement were utilized with little success. Today, the biomechanics and biology of PD as well as new diagnostic tools and especially a variety of new implants and techniques are available to hip revision surgeons. Ultraporous cups and augments, cup-cage constructs and custom triflange components have revolutionized the treatment of PD when used in various combinations with ORIF and bone grafts. For chronic PD the cup-cage construct is the most popular method of reconstruction with good medium-term results. Dislocation continues to be the leading cause of failure in all situations, followed by infection. Ultimately, surgeons today have a big enough armamentarium to select the best treatment approach. Case individualization, personal experience and improvisation are the best assets to drive treatment decisions and strategies.
Cite this article: EFORT Open Rev 2021;6:459-471. DOI: 10.1302/2058-5241.6.210022
Collapse
Affiliation(s)
- George C Babis
- 2nd Department of Orthopaedics, School of Medicine, National and Kapodistrian University of Athens, Konstantopouleio Hospital, Greece
| | - Vasileios S Nikolaou
- 2nd Department of Orthopaedics, School of Medicine, National and Kapodistrian University of Athens, Konstantopouleio Hospital, Greece
| |
Collapse
|
2
|
Mancino F, Cacciola G, Di Matteo V, De Marco D, Greenberg A, Perisano C, MA M, Sculco PK, Maccauro G, De Martino I. Reconstruction options and outcomes for acetabular bone loss in revision hip arthroplasty. Orthop Rev (Pavia) 2020; 12:8655. [PMID: 32913591 PMCID: PMC7459368 DOI: 10.4081/or.2020.8655] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 06/17/2020] [Indexed: 12/20/2022] Open
Abstract
Revision total hip arthroplasty in the setting of acetabular bone loss is a challenging procedure and requires a solid understanding of current acetabular reconstruction options. Despite major developments in the field of revision hip surgery in recent decades, reconstruction of acetabular defects remains a major problem in order to achieve primary stability and durable fixation without sacrificing additional bone stock. Although there are several ways to classify acetabular bone defects, the Paprosky classification system is the most commonly used to describe the defects and guide treatment strategy. An understanding of the bone defects associated with detailed pre-operative assessment and planning are essential elements in order to achieve satisfactory outcomes. Multiple acetabular reconstructive options are currently available including impaction bone grafting with metal mesh, reinforcement rings and antiprotrusio cage, structural allografts, cementless hemispherical cups, extra-large "jumbo cups", oblong cups, modular porous metal augments, cup-cage constructs, custom- made triflange cups, and acetabular distraction. To date, debate continues as to which technique is most effective due to the lack of long-term studies of modern reconstruction systems. Further long-term studies are necessary to assess the longevity of the different implants. The purpose of this study was to review the current literature and provide a comprehensive understanding of the available reconstruction options with their clinical outcomes.
Collapse
Affiliation(s)
- Fabio Mancino
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Giorgio Cacciola
- GIOMI Istituto Ortopedico del Mezzogiorno d’Italia Franco Scalabrino, Ganzirri, Messina, Italy
| | - Vincenzo Di Matteo
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Davide De Marco
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Alexander Greenberg
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York NY, USA
| | - Carlo Perisano
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Malahias MA
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York NY, USA
| | - Peter K. Sculco
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York NY, USA
| | - Giulio Maccauro
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Ivan De Martino
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| |
Collapse
|
3
|
A New Diagnostic Approach for Periprosthetic Acetabular Fractures Based on 3D Modeling: A Study Protocol. Diagnostics (Basel) 2019; 10:diagnostics10010015. [PMID: 31905717 PMCID: PMC7168180 DOI: 10.3390/diagnostics10010015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 12/20/2019] [Accepted: 12/27/2019] [Indexed: 12/18/2022] Open
Abstract
Periprosthetic acetabular fractures after total hip arthroplasty (THA) are mostly related to low energy trauma reduced bone quality. CT-scan is widely used to evaluate acetabular fractures, however, metal artifacts produced prosthetic implants limit the visualization of the articular surface and bone loss assessment. 3D modeling software allows us to creating tridimensional images of the bony surface, removing the metallic implants trough image segmentation. We highlight the use of 3D modeling and rapid prototyping (3D printing) for the diagnostic process of periprosthetic acetabular fracture around THA. 3D modeling software was used to improve the assessment of fracture morphology and bone quality. Moreover, the 3D images were printed in a real-life size model and used for preoperative implant templating, sizing and surgical simulation.
Collapse
|
4
|
Abstract
Chronic pelvic discontinuity is a distinct and unique challenge seen during revision total hip arthroplasty (THA) in which the superior ilium is separated from the inferior ischiopubic segment through the acetabulum, rendering the anterior and posterior columns discontinuous. The operative management of acetabular bone loss in revision THA is one of the most difficult challenges today. Common treatment options include cage reconstruction with bulk acetabular allograft, custom triflange acetabular component, a cup-cage construct, jumbo acetabular cup with porous metal augments, or acetabular distraction with a porous tantalum shell with or without modular porous augments.
Collapse
|
5
|
Acetabular defect classification in times of 3D imaging and patient-specific treatment protocols. DER ORTHOPADE 2017; 46:168-178. [PMID: 28078371 DOI: 10.1007/s00132-016-3378-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Parallel to the rising number of revision hip procedures, an increasing number of complex periprosthetic osseous defects can be expected. Stable long-term fixation of the revision implant remains the ultimate goal of the surgical protocol. Within this context, an elaborate preoperative planning process including anticipation of the periacetabular defect form and size and analysis of the remaining supporting osseous elements are essential. However, detection and evaluation of periacetabular bone defects using an unsystematic analysis of plain anteroposterior radiographs of the pelvis is in many cases difficult. Therefore, periacetabular bone defect classification schemes such as the Paprosky system have been introduced that use standardized radiographic criteria to better anticipate the intraoperative reality. Recent studies were able to demonstrate that larger defects are often underestimated when using the Paprosky classification and that the intra- and interobserver reliability of the system is low. This makes it hard to compare results in terms of defects being studied. Novel software tools that are based on the analysis of CT data may provide an opportunity to overcome the limitations of native radiographic defect analysis. In the following article we discuss potential benefits of these novel instruments against the background of the obvious limitations of the currently used native radiographic defect analysis.
Collapse
|
6
|
Hanna SA, Somerville L, McCalden RW, Naudie DD, MacDonald SJ. Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years' follow-up. Bone Joint J 2016; 98-B:28-32. [PMID: 26733512 DOI: 10.1302/0301-620x.98b1.36527] [Citation(s) in RCA: 98] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
AIMS The purpose of this study was to compare the long-term results of primary total hip arthroplasty (THA) in young patients using either a conventional (CPE) or a highly cross-linked (HXLPE) polyethylene liner in terms of functional outcome, incidence of osteolysis, radiological wear and rate of revision. METHODS We included all patients between the ages of 45 and 65 years who, between January 2000 and December 2001, had undergone a primary THA for osteoarthritis at our hospital using a CPE or HXLPE acetabular liner and a 28 mm cobalt-chrome femoral head. From a total of 160 patients, 158 (177 hips) were available for review (CPE 89; XLPE 88). The mean age, body mass index (BMI) and follow-up in each group were: CPE: 56.8 years (46 to 65); 30.7 kg/m(2) (19 to 58); 13.2 years (2.1 to 14.7) and HXLPE: 55.6 years (45 to 65); BMI: 30 kg/m(2) (18 to 51); 13.1 years (5.7 to 14.4). RESULTS The mean Harris hip score (HHS) at final follow-up was 89.3 for the CPE group and 90.9 for the HXLPE group (p = 0.078). Osteolysis was present around 15 acetabular (17%) and 16 femoral (18%) components in the CPE hips compared with none (0%) in the HXLPE hips. The mean radiological linear wear of the CPE liners was 0.11 mm/year compared with 0.035 mm/year for the HXLPE liners (p = 0.006). The cumulative implant survival, with revision for polyethylene wear as the endpoint, was 86% (95% confidence interval 78 to 94) in the CPE group and 100% in the HXLPE group at 13 years (numbers at risk at 13 years - CPE: 65, XLPE: 61). DISCUSSION This study shows that HXLPE liners are associated with significantly less osteolysis and a lower rate of revision THA than CPE liners at long-term follow-up. TAKE HOME MESSAGE The findings of this study highlight the clinical benefits of using HXLPE liners in THA and support the routine use of the material in order to improve implant longevity and to decrease the number of patients needing revision for aseptic osteolysis.
Collapse
Affiliation(s)
- S A Hanna
- University of Western Ontario, London, Ontario, N6G 2V4, Canada
| | - L Somerville
- University of Western Ontario, London, Ontario, N6G 2V4, Canada
| | - R W McCalden
- University of Western Ontario, London, Ontario, N6G 2V4, Canada
| | - D D Naudie
- University of Western Ontario, London, Ontario, N6G 2V4, Canada
| | - S J MacDonald
- University of Western Ontario, London, Ontario, N6G 2V4, Canada
| |
Collapse
|
7
|
A fluoroscopy-based planning and guidance software tool for minimally invasive hip refixation by cement injection. Int J Comput Assist Radiol Surg 2015; 11:281-96. [PMID: 26259554 PMCID: PMC4748013 DOI: 10.1007/s11548-015-1252-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Accepted: 06/18/2015] [Indexed: 11/11/2022]
Abstract
Purpose In orthopaedics, minimally invasive injection of bone cement is an established technique. We present HipRFX, a software tool for planning and guiding a cement injection procedure for stabilizing a loosening hip prosthesis. HipRFX works by analysing a pre-operative CT and intraoperative C-arm fluoroscopic images. Methods HipRFX simulates the intraoperative fluoroscopic views that a surgeon would see on a display panel. Structures are rendered by modelling their X-ray attenuation. These are then compared to actual fluoroscopic images which allow cement volumes to be estimated. Five human cadaver legs were used to validate the software in conjunction with real percutaneous cement injection into artificially created periprothetic lesions. Results Based on intraoperatively obtained fluoroscopic images, our software was able to estimate the cement volume that reached the pre-operatively planned targets. The actual median target lesion volume was 3.58 ml (range 3.17–4.64 ml). The median error in computed cement filling, as a percentage of target volume, was 5.3 % (range 2.2–14.8 %). Cement filling was between 17.6 and 55.4 % (median 51.8 %). Conclusions As a proof of concept, HipRFX was capable of simulating intraoperative fluoroscopic C-arm images. Furthermore, it provided estimates of the fraction of injected cement deposited at its intended target location, as opposed to cement that leaked away. This level of knowledge is usually unavailable to the surgeon viewing a fluoroscopic image and may aid in evaluating the success of a percutaneous cement injection intervention.
Collapse
|
8
|
Moon KH, Kang JS, Won MH, Park MJ, Choi JH. The Usefulness of Three-dimensional Computed Tomography as an Assessment of Periacetabular Osteolysis in Revision Total Hip Arthroplasty. Hip Pelvis 2015; 27:90-7. [PMID: 27536609 PMCID: PMC4972632 DOI: 10.5371/hp.2015.27.2.90] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2014] [Revised: 04/10/2015] [Accepted: 04/28/2015] [Indexed: 11/24/2022] Open
Abstract
Purpose This study was performed to determine the usefulness of three-dimensional computed tomography (3D-CT) in measuring periacetabular osteolysis by comparing the real volume of osteolysis in revision surgery. Materials and Methods Twnety-three patients who had undergone revision surgery due to periacetabular osteolysis but not included septic osteolysis and implant loosening. The mean age of patients at the time of surgery was 55.2 years. And the mean time interval between the primary total hip arthroplasty and revision surgery was 13.3 years. We measured the polyethylene wear in plain radiographs using computer assisted vector wear analysis program, the volume of acetabular osteolytic lesions in high-resolution spiral CT scans using Rapidia 3D software version 2.8 algorithms before the revision surgery were performed. Intraoperative real osteolytic volume was calculated as the sum of the volumetric increments of the acetabular cup and impacted allo-cancellous bone volume. Results Strong correlation was found between the volume of acetabular osteolytic lesions measured on 3D-CT and intraoperative real osteolytic volume which was calculated as the sum of the volumetric increments of the acetabular cup and impacted allo-cancellous bone volume. Conclusion 3D-CT is considered a useful method for assessing and measuring the volume of periacetabular osteolysis before revision surgery.
Collapse
Affiliation(s)
- Kyoung Ho Moon
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| | - Joon Soon Kang
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| | - Man Hee Won
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| | - Myoung Joo Park
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| | - Jae Hwang Choi
- Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea
| |
Collapse
|
9
|
The 27 to 29-year outcomes of the PCA total hip arthroplasty in patients younger than 50 years old. J Arthroplasty 2014; 29:2256-61. [PMID: 24636903 DOI: 10.1016/j.arth.2014.02.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Revised: 02/05/2014] [Accepted: 02/06/2014] [Indexed: 02/01/2023] Open
Abstract
We previously reported our six and 19.4-year results of arthroplasty with the PCA total hip prosthesis. We now report on the performance of this prosthesis at 27-29years. Eighty-eight consecutive primary THAs using a PCA total hip system were performed in 70 patients (mean age, 45.6±11.1years). The mean follow-up was 28.4years (27-29). The mean Harris hip score was 89 points at final follow-up. Thigh pain was reported in 22 hips (25%). The mean annual polyethylene wear was 0.182±0.03mm. There were 75 acetabular (85%) and 40 femoral (45%) osteolysis. The rate of survival after 28.4years as the end point of revision was 66% for the acetabular component and 90% for the femoral component.
Collapse
|
10
|
Sandgren B, Crafoord J, Garellick G, Carlsson L, Weidenhielm L, Olivecrona H. Computed tomography vs. digital radiography assessment for detection of osteolysis in asymptomatic patients with uncemented cups: a proposal for a new classification system based on computer tomography. J Arthroplasty 2013; 28:1608-13. [PMID: 23618751 DOI: 10.1016/j.arth.2013.01.029] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2011] [Revised: 08/27/2012] [Accepted: 01/22/2013] [Indexed: 02/01/2023] Open
Abstract
Digital radiographic images in the anterior-posterior and lateral view have been gold standard for evaluation of peri-acetabular osteolysis for patients with an uncemented hip replacement. We compared digital radiographic images and computer tomography in detection of peri-acetabular osteolysis and devised a classification system based on computer tomography. Digital radiographs were compared with computer tomography on 206 hips, with a mean follow up 10 years after surgery. The patients had no clinical signs of osteolysis and none were planned for revision surgery. On digital radiographs, 192 cases had no osteolysis and only 14 cases had osteolysis. When using computer tomography there were 184 cases showing small or large osteolysis and only 22 patients had no osteolysis. A classification system for peri-acetabular osteolysis is proposed based on computer tomography that is easy to use on standard follow up evaluation.
Collapse
Affiliation(s)
- Buster Sandgren
- Division of Orthopaedics, Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | | | | | | | | | | |
Collapse
|
11
|
Deirmengian GK, Zmistowski B, O'Neil JT, Hozack WJ. Management of acetabular bone loss in revision total hip arthroplasty. J Bone Joint Surg Am 2011; 93:1842-52. [PMID: 22005871 DOI: 10.2106/jbjs.j.01197] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Most acetabular revisions can be managed with a hemispherical component with screw fixation. Areas of segmental bone loss that preclude acetabular component stability may be managed with structural allograft or second-generation porous metal augments. Acetabular cages have a limited application but can be a useful tool in the management of massive bone loss and pelvic discontinuity.
Collapse
Affiliation(s)
- Gregory K Deirmengian
- Rothman Institute of Orthopaedics, Thomas Jefferson University Medical School, 925 Chestnut Street, Philadelphia, PA 19107, USA
| | | | | | | |
Collapse
|
12
|
Midterm results of primary total hip arthroplasty using highly cross-linked polyethylene: minimum 7-year follow-up study. J Arthroplasty 2011; 26:1014-9. [PMID: 21621960 DOI: 10.1016/j.arth.2011.03.015] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2011] [Accepted: 03/07/2011] [Indexed: 02/01/2023] Open
Abstract
The purpose of this study was to investigate the results of 113 total hip arthroplasties in 109 patients using highly cross-linked polyethylene (HXLPE) after midterm (minimum 7 years) follow-up retrospectively. The mean age at the time of operation was 57 years. Preoperative diagnosis was osteonecrosis in 81 hips and other diagnosis in 32 hips. There was no component loosening. Acetabular osteolysis was found in 12 hips (10.6 %). Mean linear HXLPE wear rate was 0.031 ± 0.012 mm/y. We analyzed the relationship between HXLPE wear rate and several variables influencing HXLPE wear. Only the cup position was related with wear rate of HXLPE significantly (P < .05). The results of total hip arthroplasties using HXLPE showed excellent results with decreased wear rate and low incidence of osteolysis after midterm follow-up.
Collapse
|
13
|
D'Amico LL, Xie L, Abell LK, Brown KT, Lopez MJ. Relationships of hip joint volume ratios with degrees of joint laxity and degenerative disease from youth to maturity in a canine population predisposed to hip joint osteoarthritis. Am J Vet Res 2011; 72:376-83. [PMID: 21355741 DOI: 10.2460/ajvr.72.3.376] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To assess relationships of acetabular volume (AV), femoral head volume (FV), and portion of the femoral head within in the acetabulum (FVIA) with each other and with degrees of hip joint laxity and degenerative joint disease from youth to maturity in dogs predisposed to developing hip joint osteoarthritis (OA). ANIMALS 46 mixed-breed half- or full-sibling hound-type dogs. PROCEDURES The distraction index (DI), AV, FV, FVIA, and degree of osteoarthritis (OA score) were quantified in 1 hip joint at 16, 32, and 104 weeks of age. Relationships among variables were evaluated within and between ages. Ratios corresponding to OA scores were compared within ages. Differences among 16-week ratios corresponding to 32-week OA scores and among 16- and 32-week ratios corresponding to 104-week OA scores were evaluated. RESULTS Significant positive relationships existed between FV and AV across ages as well as between FVIA/FV and FVIA/AV and between DI and OA score across and within most ages. Such relationships also existed within these variables across most ages. Negative relationships of DI and OA scores with FVIA/FV and FVIA/AV within and among all ages were significant. Sixteen-week AVs, FVs, and FVIAs were greater and FV/AVs and OA scores were less than 32- and 104-week values. The 32-week FVIA/FV was less than 16- and 104-week values, and the 32-week FVIA/AV was less than the 104-week value. The FVIA/FV and FVIA/AV were lower and the DI was higher with higher OA scores within and among most ages. CONCLUSIONS AND CLINICAL RELEVANCE Structural volumes in lax canine hip joints changed predictably relative to each other during growth, despite degenerative changes. Measures developed in this study may augment current diagnosis and treatment strategies for hip dysplasia in dogs.
Collapse
Affiliation(s)
- Laura L D'Amico
- Laboratory for Equine and Comparative Orthopedic Research, Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA
| | | | | | | | | |
Collapse
|
14
|
Yun HH, Shon WY, Hong SJ, Yoon JR, Yang JH. Relationship between the pelvic osteolytic volume on computed tomography and clinical outcome in patients with cementless acetabular components. INTERNATIONAL ORTHOPAEDICS 2010; 35:1453-9. [PMID: 20927513 DOI: 10.1007/s00264-010-1132-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2010] [Revised: 09/22/2010] [Accepted: 09/23/2010] [Indexed: 11/25/2022]
Abstract
The purpose of this study was to evaluate the relationship between the pelvic osteolytic volume on computed tomography (CT) and clinical outcome in patients with cementless acetabular components. We reviewed 87 patients (104 hips) who met the following inclusion criteria: (1) there was evidence of pelvic osteolysis on CT at a minium of five years postoperatively, (2) all cups and stems were radiographically stable at the time of CT, (3) the follow-up period after CT was a minimum of two years clinically. The mean pelvic osteolytic volume was 2.3 ± 6.9 cm(3). The mean Harris hip score (HHS) at CT was 92.3 ± 7.9 points. Inversely moderate correlation (r = -0.569, P < 0.05) was found between the HHS at CT and pelvic osteolytic volume. In ten cases of hips with acetabular revisions, the mean pelvic osteolytic volume was 16.3 ± 26.9 cm(3). The mean HHS at CT and HHS at reoperation was 87.6 ± 9.2 points and 73.4 ± 8.8 points, respectively, with significant difference (P < 0.05). The area under curve (ROC) analysis showed that the optimal cutoff value of the osteolytic volume was 4.8 cm(3) with 100% each for sensitivity and specificity. We conclude that the amount of pelvic osteolytic volume on CT may be used to guide treatment decision-making in patients with well-fixed cementless acetabular components who show evidence of pelvic osteolysis.
Collapse
Affiliation(s)
- Ho Hyun Yun
- Department of Orthopaedics, Seoul Veterans Hospital, Seoul, South Korea
| | | | | | | | | |
Collapse
|
15
|
Beksaç B, Salas A, González Della Valle A, Salvati EA. Wear is reduced in THA performed with highly cross-linked polyethylene. Clin Orthop Relat Res 2009; 467:1765-72. [PMID: 19082863 PMCID: PMC2690743 DOI: 10.1007/s11999-008-0661-1] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2008] [Accepted: 11/24/2008] [Indexed: 01/31/2023]
Abstract
UNLABELLED Highly cross-linked polyethylene (HCLPE) has been used extensively to decrease osteolysis and related implant failure in THA. We compared the wear rate of HCLPE and noncross-linked conventional PE (CPE) liners and the rate of radiographic calcar resorption and osteolysis in young patients (35-60 years of age) who underwent THA by one surgeon. Thirty-four patients (41 THAs) who received a hybrid THA using a HCLPE liner were match-paired for age, gender, body mass index, and diagnosis with a group of patients who underwent THA with identical implants but with a CPE liner. The minimum followup was 4 years (average, 5.3; range, 4-8 years). Using the Livermore measurement technique, the averages of total wear of the HCLPE and CPE liners were 0.01 mm (range, -0.23-0.4) and 0.64 mm (range, 0-1.7), respectively. The average annual wear was less for the HCLPE than the noncross-linked PE (0.002 mm, range, -0.05-0.1 versus 0.12 mm, range, 0-0.29, respectively). Four hips in the HCLPE group and 23 in the CPE group had calcar resorption measuring averages of 2.5 mm (range, 2-3) and 7.5 mm (range, 1.8-23.8), respectively. Periprosthetic osteolysis occurred in two and eight hips in the HCLPE and CPE groups, respectively. Longer followup is needed to determine if these findings will result in improved implant survivorship. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Burak Beksaç
- Department of Orthopedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA ,Department of Orthopedic Surgery, Weill Medical College of Cornell University, New York, NY USA
| | - Antonio Salas
- Department of Orthopedic Surgery, Hospital de Ortopedia y Traumatologia 21, Monterrey, Mexico
| | - Alejandro González Della Valle
- Department of Orthopedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA ,Department of Orthopedic Surgery, Weill Medical College of Cornell University, New York, NY USA
| | - Eduardo A. Salvati
- Department of Orthopedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA ,Department of Orthopedic Surgery, Weill Medical College of Cornell University, New York, NY USA
| |
Collapse
|