1
|
Plenzig S, Verhoff MA, Gruber H, Kunz SN. Aspiration-related pneumonia after Taser exposure - A multiple causations mechanism. Forensic Sci Int 2021; 326:110906. [PMID: 34298206 DOI: 10.1016/j.forsciint.2021.110906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 06/17/2021] [Accepted: 07/11/2021] [Indexed: 11/23/2022]
Abstract
Arrest-related deaths in the context of Conducted Electrical Weapon (CEW) deployment are rare. The evaluation of such complex events is a challenge for the forensic scientist. We present a case of a 49-year old man, who was exposed to a Taser X26P during a confrontation with the police. He lost consciousness, vomited, aspirated and died after having been hospitalized for several days at the ICU. Based on the patient´s medical history, autopsy findings, witness testimonies, and reliable clinical and toxicological blood parameters, the most probable cause and mechanisms of his death are discussed. The present work demonstrates, based on one case report, the possibilities as well as limitations of forensic assessment in CEW-related deaths.
Collapse
Affiliation(s)
- S Plenzig
- Institute of Forensic Medicine Frankfurt, Germany; Goethe, Universität Frankfurt, Germany
| | - M A Verhoff
- Institute of Forensic Medicine Frankfurt, Germany; Goethe, Universität Frankfurt, Germany
| | - H Gruber
- Institute of Forensic Medicine Frankfurt, Germany; Goethe, Universität Frankfurt, Germany
| | - S N Kunz
- Institue of Forensic Medicine, Ulm University Hospital, Germany; Ulm University, Germany.
| |
Collapse
|
2
|
Baliatsas C, Gerbecks J, Dückers MLA, Yzermans CJ. Human Health Risks of Conducted Electrical Weapon Exposure: A Systematic Review. JAMA Netw Open 2021; 4:e2037209. [PMID: 33576818 PMCID: PMC7881359 DOI: 10.1001/jamanetworkopen.2020.37209] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
IMPORTANCE Conducted electrical weapons (CEWs) are used broadly as a less-lethal force option for police officers. However, there is no clear picture of the possible health risks in humans on the basis of rigorously assessed scientific evidence from the international peer-reviewed literature. OBJECTIVE To synthesize and systematically evaluate the strength of published evidence for an association between exposure to different models of CEWs and adverse acute as well as chronic conditions. EVIDENCE REVIEW Following a preregistered review protocol, the literature search strategy was based on a search of reviews published between January 1, 2000, and April 24, 2020, of PubMed, MEDLINE, EMBASE, Web of Science, PsycINFO, and Cochrane Library, as well as relevant online databases and bibliographic sources, such as reference sections of recent publications. The identified studies were independently assessed in terms of scope, relevance, methodologic bias, and quality. Peer-reviewed publications of human studies were included, using original data and with a focus on the use of taser CEWs in the context of law enforcement. Eligible studies examined clearly defined health outcomes as dependent variables following exposure to a CEW. The review followed the relevant sections of the Preferred Reporting Items for Systematic Reviews and Meta-analyses reporting guideline. A meta-analysis could not be conducted. FINDINGS Of the 1081 unique records screened, 33 relevant studies were identified, all of them of experimental design and conducted in the US. Eleven studies had a low risk of bias and 22 had a higher bias risk. Studies focused on outcomes such as physiologic stress responses, heart rate, blood pressure, arrhythmias, or cognitive performance. Independently of bias risk, the studies reported few or no acute health problems, apart from the wounds caused by the darts. Furthermore, no long-term outcomes were studied. Most of the studies were performed on healthy, physically fit individuals (eg, police officers) in a controlled setting, with short exposure duration (5 seconds). Half of the studies, mainly those with a higher risk of bias, were at least partly funded by the manufacturer. CONCLUSIONS AND RELEVANCE Based on the findings of the reviewed studies, the risk for adverse health outcomes due to CEW exposure can be currently estimated as low. However, most of the reviewed studies had methodologic limitations. Considering that recruited participants were not representative of the population that usually encounters a CEW deployment, it is not possible to draw conclusions regarding exposure outcomes in potentially vulnerable populations or high-risk groups, such as those under the influence of substances.
Collapse
Affiliation(s)
- Christos Baliatsas
- Netherlands Institute for Health Services Research (Nivel), Utrecht, the Netherlands
| | - Jenny Gerbecks
- Netherlands Institute for Health Services Research (Nivel), Utrecht, the Netherlands
| | - Michel L. A. Dückers
- Netherlands Institute for Health Services Research (Nivel), Utrecht, the Netherlands
- ARQ National Psychotrauma Centre, Diemen, the Netherlands
- University of Groningen, Groningen, the Netherlands
| | - C. Joris Yzermans
- Netherlands Institute for Health Services Research (Nivel), Utrecht, the Netherlands
| |
Collapse
|
3
|
Dawes DM, Ho JD, Halperin HR, Fink SJ, Driver BE, Klein LR. A comparison of three conducted electrical weapons in a surrogate swine cardiac safety model. J Forensic Leg Med 2020; 77:102088. [PMID: 33242742 DOI: 10.1016/j.jflm.2020.102088] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 10/29/2020] [Accepted: 11/01/2020] [Indexed: 10/23/2022]
Abstract
We used a previously described methodology in a swine model to compare the relative cardiac safety of the Axon T7 Conducted Electrical Weapon (CEW), released in October of 2018, to two prior generations of Axon CEWs to include the X2 and the X26E. A total of 5 swine (252 total CEW exposures) were tested by alternating the three weapons at each chest exposure location. Our testing, using systemic hypotension as the quantitative surrogate for cardiac capture, demonstrated that the T7 and X2 were not statistically different. Both were superior, in terms of reduced hypotension during exposure, to the X26E. This study is important as it demonstrates that the newly released weapon is non-inferior to the X2 and superior to the X26E using this surrogate safety model. It is also important because it is the first study to examine the cardiac effects of simultaneous multi-bay exposures. Our prior study compared the X2 to the X26E but examined only single bay exposures from the X2. Lastly, we feel we have improved the methodology for studying the comparative cardiac effects of CEWs.
Collapse
Affiliation(s)
| | - Jeffrey D Ho
- Hennepin County Medical Center, Minneapolis, MN, United States.
| | | | - Sarah J Fink
- Johns Hopkins University, Baltimore, MD, United States
| | - Brian E Driver
- Hennepin County Medical Center, Minneapolis, MN, United States
| | - Lauren R Klein
- Hennepin County Medical Center, Minneapolis, MN, United States
| |
Collapse
|
4
|
Emergency Department Evaluation After Conducted Energy Weapon Use: Review of the Literature for the Clinician. J Emerg Med 2019; 57:740-746. [DOI: 10.1016/j.jemermed.2019.06.037] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 06/22/2019] [Indexed: 01/08/2023]
|
5
|
|
6
|
TASER-Einsatz – ein notfallmedizinisches Problemfeld? Notf Rett Med 2018. [DOI: 10.1007/s10049-018-0544-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
7
|
Electrical weapons and excited delirium: shocks, stress, and serum serotonin. Forensic Sci Med Pathol 2018; 14:478-483. [PMID: 30099702 DOI: 10.1007/s12024-018-0005-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/12/2018] [Indexed: 01/31/2023]
Abstract
It has been suggested that a CEW (conducted electrical weapon) exposure could elicit a stress response that could cause ExDS (excited delirium syndrome). There are some parallels between the signs of ExDS and serotonin syndrome (SS). Electroconvulsive therapy raises serotonin levels and therefore provides a plausible link between CEW applications and elevated serotonin levels. This study was designed to determine whether a CEW exposure elevates serum serotonin. A total of 31 police academy cadets were exposed to a very broad-spread 5-s CEW stimulus from a TASER brand X26 CEW. Blood was drawn before and after the exposure and at 24 h post exposure to measure serum serotonin levels. Lactic acid and cortisol levels were also compared. Median serum serotonin levels were 30 IQR (21,46), 36 IQR (22,50), and 32 IQR (21,45) ng/mL before exposure, after exposure, and 24 h after exposure (NS by pooled comparisons). The increase from baseline to post-test serotonin (∆ median = +6, ∆ mean = +2.7) ng/mL was not significant by a paired T-test (p = .29) but was significant by the Wilcoxon signed-rank test (p = .037). The increase to post-test log serotonin was not significant by a paired T-test (p = .13) but was significant by the Wilcoxon test (p = .049). All serotonin levels remained within the normal reference range of 0-200 ng/mL. Post-hoc analysis demonstrated that the study was powered to detect a ½ SD change, in log serotonin, with a 90% likelihood. With a very-broad electrode spread, CEW exposure did not significantly raise serum serotonin levels.
Collapse
|
8
|
Kunz SN, Calkins H, Adamec J, Kroll MW. Cardiac and skeletal muscle effects of electrical weapons. Forensic Sci Med Pathol 2018; 14:358-366. [DOI: 10.1007/s12024-018-9997-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/05/2018] [Indexed: 10/28/2022]
|
9
|
A comparative brief on conducted electrical weapon safety. Wien Med Wochenschr 2018; 169:185-192. [DOI: 10.1007/s10354-018-0616-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Accepted: 01/05/2018] [Indexed: 10/18/2022]
|
10
|
Kunz SN, Calkins HG, Adamec J, Kroll MW. Adrenergic and metabolic effects of electrical weapons: review and meta-analysis of human data. Int J Legal Med 2018; 132:1469-1475. [DOI: 10.1007/s00414-018-1771-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 01/08/2018] [Indexed: 10/18/2022]
|
11
|
Dawes D, Ho J. Commentary on: Gibbons J, Mojica A, Peele M. Human electrical muscular incapacitation and effects on QTc interval. J Forensic Sci https://doi.org/10.1111/1556-4029.13490. Epub 2017 April 17. J Forensic Sci 2017; 62:1418-1419. [DOI: 10.1111/1556-4029.13595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Donald Dawes
- Emergency Department; Lompoc Valley Medical Center; 1515 E Ocean Ave Lompoc CA 93436
| | - Jeffrey Ho
- Emergency Department; Hennepin County Medical Center; 701 Park Avenue South Minneapolis MN 55415
| |
Collapse
|
12
|
Gibbons JA, Mojica AJ, Peele ME. Human Electrical Muscular Incapacitation and Effects on QTc Interval. J Forensic Sci 2017; 62:1516-1521. [PMID: 28419455 DOI: 10.1111/1556-4029.13490] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Revised: 02/07/2017] [Accepted: 02/08/2017] [Indexed: 11/27/2022]
Abstract
Human Electrical Muscular Incapacitation (HEMI) is used to subdue combative individuals. Changes in cardiac electrical activity have been proposed as the cause of death in a small fraction of these individuals. The current study sought to determine whether changes in QTc interval occur after HEMI exposure. Twenty-four participants had EKG readings before a 5-second HEMI exposure and within 30 min after exposure. All subject EKGs were read by a data-blinded cardiac electrophysiologist who calculated a QT corrected (QTc) interval. QTc interval was calculated using Bazett method. QTc prolongation was defined as >430 ms and a threshold of 30 ms for identifying QTc lengthening. Five participants experienced QTc prolongation and six had QTc lengthening. One participant developed QTc prolongation exceeding 500 ms, which carries a risk of developing multifocal ventricular tachycardia. These results suggest that HEMI exposure may cause EKG changes with a risk of ventricular tachycardia.
Collapse
Affiliation(s)
- John A Gibbons
- Air Force Research Laboratory, Bioeffects Division, Airman Systems Directorate, 4141 Petroleum Road, Bldg. 3260, Fort Sam Houston, TX, 78234
| | - Andrew J Mojica
- KBRwyle Inc.: Science, Technology and Engineering, Department of Medicine, 4141 Petroleum Road, Bldg. 3260, Fort Sam Houston, TX, 78234
| | - Mark E Peele
- USARMY MEDCOM Brooke Army Medical Center, 3551 Roger Brooke Drive, Fort Sam Houston, TX, 78234
| |
Collapse
|
13
|
|
14
|
Abstract
Electromuscular incapacitating devices (EMDs) are high-voltage, low-current stimulators causing involuntary muscle contractions and sensory response. Existing evidence about cardiac effects of EMD remains inconclusive. The aim of our study was to analyze electrocardiographic, echocardiographic, and microvolt T-wave alternans (MTWA) changes induced by EMD discharge. We examined 26 volunteers (22 men; median age 30 years) who underwent single standard 5-second duration exposure to TASER X26 under continuous echocardiographic and electrocardiographic monitoring. Microvolt T-wave alternans testing was performed at baseline (MTWA-1), as well as immediately and 60 minutes after EMD exposure (MTWA-2 and MTWA-3, respectively). Mean heart rate (HR) increased significantly from 88 ± 17 beats per minute before to 129 ± 17 beats per minute after exposure (P < 0.001). However, in 2 individuals, an abrupt decrease in HR was observed. In one of them, interval between two consecutive beats increased up to 1.7 seconds during the discharge. New onset of supraventricular premature beats was observed after discharge in 1 patient. Results of MTWA-1, MTWA-2, and MTWA-3 tests were positive in one of the subjects, each time in a different case. Standard EMD exposure can be associated with a nonuniform reaction of HR and followed by heart rhythm disturbances. New MTWA positivity can reflect either the effect of EMD exposure or a potential false positivity of MTWA assessments.
Collapse
|
15
|
Strote J, Maher P. Civilian use of a conducted electrical weapon. Am J Emerg Med 2015; 33:606.e1-2. [DOI: 10.1016/j.ajem.2014.10.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2014] [Accepted: 10/02/2014] [Indexed: 11/30/2022] Open
|
16
|
Lésions induites par les pistolets à impulsion électrique de type Taser®. ANNALES FRANCAISES DE MEDECINE D URGENCE 2015. [DOI: 10.1007/s13341-014-0487-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
17
|
Jauchem JR. Exposures to conducted electrical weapons (including TASER® devices): how many and for how long are acceptable? J Forensic Sci 2014; 60 Suppl 1:S116-29. [PMID: 25443856 DOI: 10.1111/1556-4029.12672] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2013] [Revised: 01/28/2014] [Accepted: 02/03/2014] [Indexed: 01/04/2023]
Abstract
TASER(®) conducted electrical weapons (CEWs) are an important law-enforcement tool. The purposes of this study are a) to review recent literature regarding potential pathophysiological responses to applications of CEWs, and other related issues and b) to evaluate whether enough data exist to determine the acceptability of longer-duration (or repeated) exposures. This is a narrative review, using a multidisciplinary approach of analyzing reports from physiological, legal-medical, and police-strategy literature sources. In general, short-duration exposures to CEWs result in limited effects. Longer-duration or repeated exposures may be utilized with caution, although there are currently not enough data to determine the acceptability of all types of exposures. Data examined in the literature have inherent limitations. Appropriateness of specific types of CEW usage may be determined by individual police agencies, applying risk/benefit analyses unique to each organization. While more research is recommended, initial concepts of potential future long-duration or repeated CEW applications are presented.
Collapse
Affiliation(s)
- James R Jauchem
- Bio-effects Division, Human Effectiveness Directorate, 711th Human Performance Wing, U.S. Air Force Research Laboratory, Fort Sam Houston, TX, 78234
| |
Collapse
|
18
|
Jauchem JR, Cerna CZ, Lim TY, Seaman RL. Exposures of Sus scrofa to a TASER(®) conducted electrical weapon: no effects on 2-dimensional gel electrophoresis patterns of plasma proteins. Forensic Sci Med Pathol 2014; 10:526-34. [PMID: 25319243 DOI: 10.1007/s12024-014-9606-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/25/2014] [Indexed: 11/25/2022]
Abstract
In an earlier study, we found significant changes in red-blood-cell, leukocyte, and platelet counts, and in red-blood-cell membrane proteins, following exposures of anesthetized pigs to a conducted electrical weapon. In the current study, we examined potential changes in plasma proteins [analyzed via two-dimensional gel electrophoresis (2-DGE)] following two 30 s exposures of anesthetized pigs (Sus scrofa) to a TASER (®) C2 conducted electrical weapon. Patterns of proteins, separated by 2-DGE, were consistent and reproducible between animals and between times of sampling. We determined that the blood plasma collection, handling, storage, and processing techniques we used are suitable for swine blood. There were no statistically significant changes in plasma proteins following the conducted-electrical-weapon exposures. Overall gel patterns of fibrinogen were similar to results of other studies of both pigs and humans (in control settings, not exposed to conducted electrical weapons). The lack of significant changes in plasma proteins may be added to the body of evidence regarding relative safety of TASER C2 device exposures.
Collapse
Affiliation(s)
- James R Jauchem
- Bio-Effects Division, Human Effectiveness Directorate, 711th Human Performance Wing, US Air Force Research Laboratory, 711 HPW/RHDR, 4141 Petroleum Road, Fort Sam Houston, TX, 78234, USA,
| | | | | | | |
Collapse
|
19
|
Incapacitation recovery times from a conductive electrical weapon exposure. Forensic Sci Med Pathol 2014; 10:203-7. [DOI: 10.1007/s12024-014-9551-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/26/2014] [Indexed: 10/25/2022]
|
20
|
Ho JD, Dawes DM, Nystrom PC, Collins DP, Nelson RS, Moore JC, Miner JR. Markers of acidosis and stress in a sprint versus a conducted electrical weapon. Forensic Sci Int 2013; 233:84-9. [DOI: 10.1016/j.forsciint.2013.08.022] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2013] [Revised: 08/21/2013] [Accepted: 08/23/2013] [Indexed: 11/15/2022]
|
21
|
Ho JD, Dawes DM, Chang RJ, Nelson RS, Miner JR. Physiologic effects of a new-generation conducted electrical weapon on human volunteers. J Emerg Med 2013; 46:428-35. [PMID: 24238599 DOI: 10.1016/j.jemermed.2013.08.069] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2013] [Revised: 05/16/2013] [Accepted: 08/15/2013] [Indexed: 11/19/2022]
Abstract
BACKGROUND Conducted electrical weapons (CEWs) are used by law enforcement to restrain or repel potentially violent persons. The TASER X2 CEW is a next-generation device with new technology, including new electrical waveform and output specifications. It has not previously been studied in humans. OBJECTIVE The objective of this study was to evaluate the human physiologic effect of a new-generation CEW. METHODS This was a prospective, observational human study. Volunteers received a 10-s exposure via deployed probes from an X2 CEW in the abdomen and upper thigh. Measured data included vital signs; 12-lead electrocardiograms; and blood serum biomarkers before, immediately after, and 24 h post exposure. Biomarkers measured included pH, lactate, potassium, creatine kinase (CK), and troponin-I. Real-time spirometry and echocardiography were performed before, during, and after the exposure. RESULTS Ten volunteers completed the study. There were no important changes in vital signs or potassium. Median increase in lactate as a consequence of the exposure was 1.2 mg/dL (range 0.6-2.8 mg/dL). Median change in pH was -0.031 (range -0.011 to -0.067). No subject had a positive troponin. Median change in CK at 24 h was 313 ng/mL (range -40 to 3418 ng/mL). There was no evidence of respiratory impairment. Baseline median minute ventilation was 14.2 L/min, increased to 21.6 L/min intra-exposure (p = 0.05), and remained elevated at 21.6 L/min post exposure (p = 0.01). CONCLUSIONS There was no evidence of dangerous physiology found in the measured parameters. The physiologic effects of the X2 CEW are similar to older-generation CEWs. We encourage further study to validate these results.
Collapse
Affiliation(s)
- Jeffrey D Ho
- Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, Minnesota; Meeker County Sheriff's Office, Litchfield, Minnesota
| | - Donald M Dawes
- Department of Emergency Medicine, Lompoc Valley Medical Center, Lompoc, California; Santa Barbara Police Department, Santa Barbara, California
| | - Richard J Chang
- Department of Emergency Medicine, Providence Regional Medical Center, Everett, Washington
| | - Rebecca S Nelson
- Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, Minnesota
| | - James R Miner
- Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, Minnesota
| |
Collapse
|
22
|
Blood lactate concentration after exposure to conducted energy weapons (including TASER® devices): is it clinically relevant? Forensic Sci Med Pathol 2013; 9:386-94. [PMID: 23605975 DOI: 10.1007/s12024-013-9436-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/15/2013] [Indexed: 10/26/2022]
Abstract
In previous studies, blood lactate concentration (BLac) consistently increased in anesthetized animals and in human subjects after exposures to TASER(®) conducted energy weapons (CEWs). Some have suggested the increased BLac would have detrimental consequences. In the current review, the following are evaluated: (a) the nature of muscle contractions due to CEWs, (b) general aspects of increased BLac, (c) previous studies of conventional neuromuscular electrical stimulation and CEW exposures, and (d) BLac in disease states. On the basis of these analyses, one can conclude that BLac, per se (independent of acidemia), would not be clinically relevant immediately after short-duration CEW applications, due to the short time course of any increase.
Collapse
|
23
|
Vanmeenen KM, Lavietes MH, Cherniack NS, Bergen MT, Teichman R, Servatius RJ. Respiratory and Cardiovascular Response during Electronic Control Device Exposure in Law Enforcement Trainees. Front Physiol 2013; 4:78. [PMID: 23616772 PMCID: PMC3629983 DOI: 10.3389/fphys.2013.00078] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Accepted: 03/22/2013] [Indexed: 11/16/2022] Open
Abstract
Objective: Law enforcement represents a large population of workers who may be exposed to electronic control devices (ECDs). Little is known about the potential effect of exposure to these devices on respiration or cardiovascular response during current discharge. Methods: Participants (N = 23) were trainees exposed to 5 s of an ECD (Taser X26®) as a component of training. Trainees were asked to volitionally inhale during exposure. Respiratory recordings involved a continuous waveform recorded throughout the session including during the exposure period. Heart rate was calculated from a continuous pulse oximetry recording. Results: The exposure period resulted in the cessation of normal breathing patterns in all participants and in particular a decrease in inspiratory activity. No significant changes in heart rate during ECD exposure were found. Conclusion: This is the first study to examine breathing patterns during ECD exposure with the resolution to detect changes over this discrete period of time. In contrast to reports suggesting respiration is unaffected by ECDs, present evidence suggests that voluntary inspiration is severely compromised. There is no evidence of cardiac disruption during ECD exposure.
Collapse
Affiliation(s)
- Kirsten M Vanmeenen
- Stress and Motivated Behavior Institute, New Jersey Medical School, University of Medicine and Dentistry of New Jersey Newark, NJ, USA ; Department of Veterans Affairs Medical Center, New Jersey Health Care System East Orange, NJ, USA
| | | | | | | | | | | |
Collapse
|
24
|
Jauchem JR, Bernhard JA, Cerna CZ, Lim TY, Seaman RL, Tarango M. Effects of a TASER® conducted energy weapon on the circulating red-blood-cell population and other factors in Sus scrofa. Forensic Sci Med Pathol 2013; 9:308-20. [PMID: 23543463 DOI: 10.1007/s12024-013-9423-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/13/2013] [Indexed: 10/27/2022]
Abstract
In previous studies hematocrit has been consistently increased in an anesthetized animal model after exposures to TASER(®) conducted energy weapons (CEWs). In the present study we analyzed changes in blood cell counts and red blood cell membrane proteins following two 30-s applications of a TASER C2 device (which is designed for civilian use). Hematocrit increased significantly from 33.2 ± 2.4 (mean ± SD) to 42.8 ± 4.6 % immediately after CEW exposure of eleven pigs (Sus scrofa). Red blood cell count increased significantly from 6.10 ± 0.55 × 10(12)/L to 7.45 ± 0.94 × 10(12)/L, and mean corpuscular volume increased significantly from 54.5 ± 2.4 fl to 57.8 ± 2.6 fl. Mean corpuscular hemoglobin concentration decreased significantly from 20.5 ± 0.7 to 18.5 ± 0.6 mM. Thirty protein spots (from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis, selected for detailed comparison) exhibited greater densities 30-min post-exposure compared with pre-exposure values. A greater number of echinocytes were observed following CEW exposure. On the basis of these results it appears that, during the strong muscle contractions produced by TASER CEWs, a specific population of red blood cells (RBCs) may be released from the spleen or other reservoirs within the body. The total time of CEW exposure in the present study was relatively long compared with exposures in common law-enforcement scenarios. Despite statistically significant changes in red blood cell counts (and other measures directly related to RBCs), the alterations were short-lived. The transient nature of the changes would be likely to counteract any potentially detrimental effects.
Collapse
Affiliation(s)
- James R Jauchem
- Bio-Effects Division, Human Effectiveness Directorate, 711th Human Performance Wing, U.S. Air Force Research Laboratory, Fort Sam Houston, TX 78234, USA.
| | | | | | | | | | | |
Collapse
|
25
|
An evaluation of two conducted electrical weapons and two probe designs using a swine comparative cardiac safety model. Forensic Sci Med Pathol 2013; 9:333-42. [DOI: 10.1007/s12024-013-9422-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/10/2013] [Indexed: 11/26/2022]
|
26
|
Jauchem JR. Author's response: My response to Dr. Dawes et al.'s letter follows (owing to the U.S. Air Force Research Laboratory's approval process required of authors, the response could not be submitted to the Journal of Forensic Sciences in a timely manner. J Forensic Sci 2011; 56:1671-2. [PMID: 22040045 DOI: 10.1111/j.1556-4029.2011.01922.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
27
|
Azadani PN, Tseng ZH, Ermakov S, Marcus GM, Lee BK. Funding source and author affiliation in TASER research are strongly associated with a conclusion of device safety. Am Heart J 2011; 162:533-7. [PMID: 21884872 DOI: 10.1016/j.ahj.2011.05.025] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2011] [Accepted: 05/21/2011] [Indexed: 11/26/2022]
Abstract
BACKGROUND Controversy exists regarding the safety of electrical stun guns (TASERs). Much of the research on TASERs is funded by the maker of the device and, therefore, could be biased. We sought to determine if funding source or author affiliation is associated with TASER research conclusions. METHODS MEDLINE was searched for TASER or electrical stun gun to identify relevant studies. All human and animal studies published up to September 01, 2010, were included. Reviews, editorials, letters, and case reports were excluded from the analysis. Two independent reviewers blinded to this study hypothesis evaluated each article with regard to conclusions of TASER safety. RESULTS Fifty studies were reviewed: 32 (64%) were human studies and 18 (36%) were animal studies. Twenty-three (46%) studies were funded by TASER International or written by an author affiliated with the company. Of these, 22 (96%) concluded that TASERs are unlikely harmful (26%) or not harmful (70%). In contrast, of the 22 studies not affiliated with TASER, 15 (55%) concluded that TASERs are unlikely harmful (29%) or not harmful (26%). A study with any affiliation with TASER International had nearly 18 times higher odds to conclude that the TASER is likely safe as compared with studies without such affiliation (odds ratio 17.6, 95% CI 2.1-150.1, P = .001). CONCLUSIONS Studies funded by TASER and/or written by an author affiliated with the company are substantially more likely to conclude that TASERs are safe. Research supported by TASER International may thus be significantly biased in favor of TASER safety.
Collapse
|
28
|
Dawes DM, Ho JD, Cole JB. Response to "Acute Agitated Delirious State Associated With TASER Exposure". J Natl Med Assoc 2011; 103:986-8. [DOI: 10.1016/s0027-9684(15)30458-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
29
|
Electronic Control Device Exposure: A Review of Morbidity and Mortality. Ann Emerg Med 2011; 58:178-88. [DOI: 10.1016/j.annemergmed.2011.01.023] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2010] [Revised: 12/20/2010] [Accepted: 01/28/2011] [Indexed: 11/21/2022]
|
30
|
Giaconi JC, Ries MD, Steinbach LS. Stun gun induced myotendinous injury of the iliopsoas and gluteus minimus. Skeletal Radiol 2011; 40:783-7. [PMID: 21298429 DOI: 10.1007/s00256-011-1105-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2010] [Revised: 01/04/2011] [Accepted: 01/13/2011] [Indexed: 02/02/2023]
Abstract
We report a 57-year-old man with a complete tear of his iliopsoas tendon at the distal myotendinous junction, a near complete tear of the iliopsoas tendon at the lesser trochanter of the femur, and a high-grade tear of his gluteus minimus tendon at the greater trochanter of the femur after being struck by a stun gun in the proximal left thigh. The stun gun discharge resulted in a forced contraction of the left hip flexor muscles, which resulted in pain, weakness and difficulty with active hip flexion. Three months after the being struck with the stun gun, the patient underwent magnetic resonance imaging (MRI) of the left hip. MRI of the left hip revealed a complete tear of the left iliopsoas tendon from the lesser trochanter with 4 cm of proximal retraction and a high-grade strain of the gluteus minimus tendon at the greater trochanter. The distal iliopsoas myotendinous junction and lesser trochanter tendon insertion were surgically repaired. This case illustrates that a stun gun can cause acute rupture of the iliopsoas tendon and tear of the gluteus minimus tendon, which is well visualized on MRI.
Collapse
Affiliation(s)
- Joseph C Giaconi
- S. Mark Taper Foundation Imaging Center, Cedars Sinai Medical Center, 8700 Beverly Boulevard, Suite -335, Los Angeles, CA 90048, USA.
| | | | | |
Collapse
|
31
|
Pathophysiologic changes due to TASER® devices versus excited delirium: Potential relevance to deaths-in-custody? J Forensic Leg Med 2011; 18:145-53. [PMID: 21550562 DOI: 10.1016/j.jflm.2011.01.014] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2010] [Revised: 01/13/2011] [Accepted: 01/26/2011] [Indexed: 11/21/2022]
|