1
|
Wu S, Yin Y, Sun C, Song W. Efficient Synthesis of Highly Photo‐stable N‐doped Carbon Quantum Dots and their Applications in Detection and Cellular Imaging of Mercury Ions. ChemistrySelect 2022. [DOI: 10.1002/slct.202202540] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Shunwei Wu
- School of Chemical Engineering Qinghai University Xining 810016 China
| | - Yongzheng Yin
- School of Chemical Engineering Qinghai University Xining 810016 China
| | - Chunyan Sun
- School of Chemical Engineering Qinghai University Xining 810016 China
| | - Weijun Song
- School of Chemical Engineering Qinghai University Xining 810016 China
| |
Collapse
|
2
|
Development of sensitive and portable immunosensors based on signal amplification probes for monitoring the mercury(II) ions. Biosens Bioelectron 2022; 217:114676. [PMID: 36126556 DOI: 10.1016/j.bios.2022.114676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 08/18/2022] [Accepted: 08/28/2022] [Indexed: 11/02/2022]
Abstract
Mercury ion (Hg2+) as a major environmental pollutant threatens human health even at very low concentrations, so it is essential to monitor mercury residues in food. In this study, Hg2+ was conjugated with protein carrier using 1-(4-Isothiocyanobenzyl) ethylenediamine N, N, N', N'-tetraacetic acid (ITCBE) as a bifunctional chelator. 7A1 monoclonal antibody (mAb) against Hg2+-ITCBE with high affinity (7.3 × 109 L/moL) and good specificity was obtained by cell fusion technology and performed to establish immunosensors. Immunochromatographic test strip using colloidal gold nanoparticles (AuNP with an average diameter of 18 nm) as signal reporter showed low sensitivity. Signal amplification probes including larger multi-branched gold nanoflowers (AuNF) and latex microspheres (LM) were employed to enhance the sensitivity of immunosensors. The visible limit of detection (vLOD) of the AuNF- and LM-based strip were determined to be 50 ng/mL and 25 ng/mL respectively, showing more sensitive than that of AuNP-based strip (200 ng/mL). Quantitative analysis showed that AuNF-based strip exhibited lower quantitative limit of detection (qLOD) (0.44 ng/mL) which was 20-fold lower than that of AuNP-based strip (8.92 ng/mL) for determination of Hg2+, and LM-based strip (0.49 ng/mL) was 18 times as sensitive as AuNP-based strip. In summary, the developed immunosensors using AuNF and LM as signal amplification probes exhibited excellent sensitivity and provided portable, on-site detection for Hg2+.
Collapse
|
3
|
Artavia G, Cortés-Herrera C, Granados-Chinchilla F. Selected Instrumental Techniques Applied in Food and Feed: Quality, Safety and Adulteration Analysis. Foods 2021; 10:1081. [PMID: 34068197 PMCID: PMC8152966 DOI: 10.3390/foods10051081] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 03/13/2021] [Accepted: 03/19/2021] [Indexed: 12/28/2022] Open
Abstract
This review presents an overall glance at selected instrumental analytical techniques and methods used in food analysis, focusing on their primary food science research applications. The methods described represent approaches that have already been developed or are currently being implemented in our laboratories. Some techniques are widespread and well known and hence we will focus only in very specific examples, whilst the relatively less common techniques applied in food science are covered in a wider fashion. We made a particular emphasis on the works published on this topic in the last five years. When appropriate, we referred the reader to specialized reports highlighting each technique's principle and focused on said technologies' applications in the food analysis field. Each example forwarded will consider the advantages and limitations of the application. Certain study cases will typify that several of the techniques mentioned are used simultaneously to resolve an issue, support novel data, or gather further information from the food sample.
Collapse
Affiliation(s)
- Graciela Artavia
- Centro Nacional de Ciencia y Tecnología de Alimentos, Sede Rodrigo Facio, Universidad de Costa Rica, San José 11501-2060, Costa Rica;
| | - Carolina Cortés-Herrera
- Centro Nacional de Ciencia y Tecnología de Alimentos, Sede Rodrigo Facio, Universidad de Costa Rica, San José 11501-2060, Costa Rica;
| | | |
Collapse
|
4
|
Trends in sensor development toward next-generation point-of-care testing for mercury. Biosens Bioelectron 2021; 183:113228. [PMID: 33862396 DOI: 10.1016/j.bios.2021.113228] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/02/2021] [Accepted: 04/03/2021] [Indexed: 01/01/2023]
Abstract
Mercury is one of the most common heavy metals and a major environmental pollutant that affects ecosystems. Since mercury and its compounds are toxic to humans, even at low concentrations, it is very important to monitor mercury contamination in water and foods. Although conventional mercury detection methods, including inductively coupled plasma mass spectrometry, atomic absorption spectroscopy, and gas chromatography-mass spectrometry, exhibit excellent sensitivity and accuracy, they require operation by an expert in a sophisticated and fully controlled laboratory environment. To overcome these limitations and realize point-of-care testing, many novel methods for direct sample analysis in the field have recently been developed by improving the speed and simplicity of detection. Commonly, these unconventional sensors rely on colorimetric, fluorescence, or electrochemical mechanisms to transduce signals from mercury. In the case of colorimetric and fluorescent sensors, benchtop methods have gradually evolved through technology convergence to give standalone platforms, such as paper-based assays and lab-on-a-chip systems, and portable measurement devices, such as smartphones. Electrochemical sensors that use screen-printed electrodes with carbon or metal nanomaterials or hybrid materials to improve sensitivity and stability also provide promising detection platforms. This review summarizes the current state of sensor platforms for the on-field detection of mercury with a focus on key features and recent developments. Furthermore, trends for next-generation mercury sensors are suggested based on a paradigm shift to the active integration of cutting-edge technologies, such as drones, systems based on artificial intelligence, machine learning, and three-dimensional printing, and high-quality smartphones.
Collapse
|
5
|
Krata AA, Wojciechowski M, Vassileva E, Bulska E. Reference measurements of mercury species in seafood using isotope dilution inductively coupled plasma mass spectrometry. J Food Compost Anal 2020. [DOI: 10.1016/j.jfca.2019.103381] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
6
|
Speciation of mercury in water and biological samples by eco-friendly ultrasound-assisted deep eutectic solvent based on liquid phase microextraction with electrothermal atomic absorption spectrometry. Talanta 2019; 197:310-318. [DOI: 10.1016/j.talanta.2019.01.018] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 01/03/2019] [Accepted: 01/04/2019] [Indexed: 01/10/2023]
|
7
|
Speciation of zinc in fish feed by size exclusion chromatography coupled to inductively coupled plasma mass spectrometry - using fractional factorial design for method optimisation and mild extraction conditions. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1104:262-268. [PMID: 30576954 DOI: 10.1016/j.jchromb.2018.11.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 10/19/2018] [Accepted: 11/08/2018] [Indexed: 11/21/2022]
Abstract
Zinc (Zn) is an element essential to all living organisms and it has an important role as a cofactor of several enzymes. In fish, Zn deficiency has been associated with impaired growth, cataracts, skeletal abnormalities and reduced activity of various Zn metalloenzymes. Fish meal and fish oil traditionally used in salmon feed preparation are being replaced by plant-based ingredients. Zinc additives are supplemented to salmon feed to ensure adequate Zn levels, promoting good health and welfare in Atlantic salmon (Salmo salar). The main objective of the present study was to evaluate Zn species found in an Atlantic salmon feed. This work describes a Zn extraction method that was optimized using a fractional factorial design (FFD), whereby the effect of six factors could be studied by performing only eight experiments. The effects of the type of extraction solution and its molar concentration, pH, presence of sodium dodecyl sulphate, temperature and extraction time on Zn extraction were investigated. Mild extraction conditions were chosen in order to keep the Zn species intact. Total Zn (soluble fractions and non-soluble fractions) was determined by inductively coupled plasma mass spectrometry (ICP-MS). The highest Zn recovery was obtained using 100 mM Tris-HCl, pH 8.5 at a temperature of 4 °C for 24 h where the total Zn in soluble fraction and non-soluble fraction was 9.9 ± 0.2% and 98 ± 6%, respectively. Zinc speciation analysis (on the soluble fractions) was further conducted by size exclusion inductively coupled plasma mass spectroscopy (SEC-ICP-MS). The SEC-ICP-MS method provided qualitative and semi-quantitative information regarding Zn species present in the soluble fractions of the feed. Four Zn-containing peaks were found, each with different molecular weights: Peak 1 (high molecular weight - ≥600 kDa), peak 2 and peak 3 (medium molecular weight - 32 to 17 kDa) were the least abundant (1-6%), while peak 4 (low molecular weight - 17 to 1.36 kDa) was the most abundant (84-95%).
Collapse
|
8
|
Covaci E, Senila M, Ponta M, Darvasi E, Petreus D, Frentiu M, Frentiu T. Methylmercury determination in seafood by photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry. Talanta 2017; 170:464-472. [PMID: 28501197 DOI: 10.1016/j.talanta.2017.04.036] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Revised: 04/12/2017] [Accepted: 04/15/2017] [Indexed: 12/25/2022]
Abstract
A non-chromatographic method based on double liquid-liquid extraction and measurements by UV photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry was developed and characterized for methylmercury determination in seafood. Samples were prepared following the procedure recommended in JRC Technical Report of European Commission formerly proposed for the determination of methylmercury in seafood by thermal decomposition atomic absorption spectrometry, namely confinement of Hg species in 47% HBr solution, extraction of CH3Hg+ in toluene and back-extraction in 1% l-cysteine aqueous solution. Mercury cold vapor was generated by flow injection UV photo-reduction from CH3Hg+ in 0.6molL-1 HCOOH, while quantification was performed against external Hg2+ aqueous standards and measuring Hg 253.652nm emission using a low power/Ar consumption plasma microtorch (15W, 100mLmin-1) and a low resolution microspectrometer (Ocean Optics). The figures of merit and analytical capability were assessed by analyzing certified reference materials and test samples of fish fillet and discussed in relation with requirements for Hg determination in seafood in European legislation (Decisions 2007/333/EC and 2002/657/EC) as well as compared to performances achieved in thermal decomposition atomic absorption spectrometry. The limit of detection and quantification of 2µgkg-1 and 6µgkg-1 respectively, precision of 2.7-9.4% and accuracy of 99±8% of the proposed method for the determination of CH3Hg+ fulfill the demands of European legislation for Hg quantification. The limit of detection and quantification were better than those in the used reference method or other non-/chromatographic methods taken for comparison. The analysis of certified reference materials and the Bland and Altman test performed on 12 test samples confirmed trueness of the proposed method and its reliability for the determination of traces of CH3Hg+ with 95% confidence level. The proposed method fulfills several demands of the eco-scale concept, is sensitive, simple and safe related to sample preparation through elimination of classical, harmful reductants and attractive by using economical miniaturized instrumentation incorporating a low power and low Ar consumption plasma.
Collapse
Affiliation(s)
- Eniko Covaci
- Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania
| | - Marin Senila
- National Institute for Research and Development of Optoelectronics Bucharest, Research Institute for Analytical Instrumentation, Donath 67, 400293 Cluj-Napoca, Romania
| | - Michaela Ponta
- Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania
| | - Eugen Darvasi
- Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania
| | - Dorin Petreus
- Technical University of Cluj-Napoca, Faculty of Electronics, Telecommunications and Information Technology, Gh. Baritiu 26-28, 40002 Cluj-Napoca, Romania
| | - Maria Frentiu
- National Institute for Research and Development of Optoelectronics Bucharest, Research Institute for Analytical Instrumentation, Donath 67, 400293 Cluj-Napoca, Romania
| | - Tiberiu Frentiu
- Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania.
| |
Collapse
|
9
|
C-phycocyanin from Spirulina maxima as a Green Fluorescent Probe for the Highly Selective Detection of Mercury(II) in Seafood. FOOD ANAL METHOD 2016. [DOI: 10.1007/s12161-016-0759-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
10
|
Hecht ES, Oberg AL, Muddiman DC. Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:767-85. [PMID: 26951559 PMCID: PMC4841694 DOI: 10.1007/s13361-016-1344-x] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 01/14/2016] [Accepted: 01/16/2016] [Indexed: 05/07/2023]
Abstract
Mass spectrometry (MS) has emerged as a tool that can analyze nearly all classes of molecules, with its scope rapidly expanding in the areas of post-translational modifications, MS instrumentation, and many others. Yet integration of novel analyte preparatory and purification methods with existing or novel mass spectrometers can introduce new challenges for MS sensitivity. The mechanisms that govern detection by MS are particularly complex and interdependent, including ionization efficiency, ion suppression, and transmission. Performance of both off-line and MS methods can be optimized separately or, when appropriate, simultaneously through statistical designs, broadly referred to as "design of experiments" (DOE). The following review provides a tutorial-like guide into the selection of DOE for MS experiments, the practices for modeling and optimization of response variables, and the available software tools that support DOE implementation in any laboratory. This review comes 3 years after the latest DOE review (Hibbert DB, 2012), which provided a comprehensive overview on the types of designs available and their statistical construction. Since that time, new classes of DOE, such as the definitive screening design, have emerged and new calls have been made for mass spectrometrists to adopt the practice. Rather than exhaustively cover all possible designs, we have highlighted the three most practical DOE classes available to mass spectrometrists. This review further differentiates itself by providing expert recommendations for experimental setup and defining DOE entirely in the context of three case-studies that highlight the utility of different designs to achieve different goals. A step-by-step tutorial is also provided.
Collapse
Affiliation(s)
- Elizabeth S Hecht
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Ann L Oberg
- Division of Biomedical Statistics and Informatics, Department of Health Sciences Research, Mayo Clinic, Rochester, MN, 55905, USA
| | - David C Muddiman
- W. M. Keck FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|