1
|
Sohn AL, Kibbe RR, Dioli OE, Hector EC, Bai H, Garrard KP, Muddiman DC. A statistical approach to system suitability testing for mass spectrometry imaging. Rapid Commun Mass Spectrom 2024; 38:e9725. [PMID: 38456255 PMCID: PMC10926995 DOI: 10.1002/rcm.9725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 02/05/2024] [Accepted: 02/06/2024] [Indexed: 03/09/2024]
Abstract
RATIONALE Mass spectrometry imaging (MSI) elevates the power of conventional mass spectrometry (MS) to multidimensional space, elucidating both chemical composition and localization. However, the field lacks any robust quality control (QC) and/or system suitability testing (SST) protocols to monitor inconsistencies during data acquisition, both of which are integral to ensure the validity of experimental results. To satisfy this demand in the community, we propose an adaptable QC/SST approach with five analyte options amendable to various ionization MSI platforms (e.g., desorption electrospray ionization, matrix-assisted laser desorption/ionization [MALDI], MALDI-2, and infrared matrix-assisted laser desorption electrospray ionization [IR-MALDESI]). METHODS A novel QC mix was sprayed across glass slides to collect QC/SST regions-of-interest (ROIs). Data were collected under optimal conditions and on a compromised instrument to construct and refine the principal component analysis (PCA) model in R. Metrics, including mass measurement accuracy and spectral accuracy, were evaluated, yielding an individual suitability score for each compound. The average of these scores is utilized to inform if troubleshooting is necessary. RESULTS The PCA-based SST model was applied to data collected when the instrument was compromised. The resultant SST scores were used to determine a statistically significant threshold, which was defined as 0.93 for IR-MALDESI-MSI analyses. This minimizes the type-I error rate, where the QC/SST would report the platform to be in working condition when cleaning is actually necessary. Further, data scored after a partial cleaning demonstrate the importance of QC and frequent full instrument cleaning. CONCLUSIONS This study is the starting point for addressing an important issue and will undergo future development to improve the efficiency of the protocol. Ultimately, this work is the first of its kind and proposes this approach as a proof of concept to develop and implement universal QC/SST protocols for a variety of MSI platforms.
Collapse
Affiliation(s)
- Alexandria L. Sohn
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - Russell R. Kibbe
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - Olivia E. Dioli
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - Emily C. Hector
- Department of Statistics, North Carolina State University, Raleigh, NC 27695
| | - Hongxia Bai
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - Kenneth P. Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695
| |
Collapse
|
2
|
Ashbacher SM, Mills Q, Sohn AL, Xie DY, Muddiman DC. Incorporation of Three Different Optical Trains into the IR-MALDESI Mass Spectrometry Imaging Platform to Characterize Artemisia annua. J Am Soc Mass Spectrom 2024. [PMID: 38686539 DOI: 10.1021/jasms.4c00060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
Artemisinin is the leading medication for the treatment of malaria and is only produced naturally in Artemisia annua. The localization of artemisinin in both the glandular and non-glandular trichomes of the plant makes it an ideal candidate for mass spectrometry imaging (MSI) as a model system for method development. Infrared matrix-assisted laser desorption electrospray ionization MSI (IR-MALDESI-MSI) has the capability to detect hundreds to thousands of analytes simultaneously, providing abundance information in conjunction with species localization throughout a sample. The development of several new optical trains and their application to the IR-MALDESI-MSI platform has improved data quality in previous proof-of-concept experiments but has not yet been applied to analysis of native biological samples, especially the MSI analysis of plants. This study aimed to develop a workflow and optimize MSI parameters, specifically the laser optical train, for the analysis of Artemisia annua with the NextGen IR-MALDESI platform coupled to an Orbitrap Exploris 240 mass spectrometer. Two laser optics were compared to the conventional set up, of which include a Schwarzschild-like reflective objective and a diffractive optical element (DOE). These optics, respectively, enhance the spatial resolution of imaging experiments or create a square spot shape for top-hat imaging. Ultimately, we incorporated and characterized three different optical trains into our analysis of Artemisia annua to study metabolites in the artemisinin pathway. These improvements in our workflow, resulted in high spatial resolution and improved ion abundance from previous work, which will allow us to address many different questions in plant biology beyond this model system.
Collapse
|
3
|
Kibbe RR, Muddiman DC. Quantitative mass spectrometry imaging (qMSI): A tutorial. J Mass Spectrom 2024; 59:e5009. [PMID: 38488849 DOI: 10.1002/jms.5009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Accepted: 01/29/2024] [Indexed: 03/19/2024]
Abstract
Mass spectrometry imaging (MSI) is an analytical technique that enables the simultaneous detection of hundreds to thousands of chemical species while retaining their spatial information; usually, MSI is applied to biological tissues. Combining these elements can create ion images, which allows for the identification and localization of multiple chemical species within the sample. Being able to produce molecular images of biological tissues has already impacted the study of health and disease; however, the next logical step is being able to combine MSI with quantitative mass spectrometry methods to both quantify and determine the localization of disease progression or drug action. In this tutorial, we will detail the main factors to consider when designing a qMSI experiment and highlight the methods that have been developed to overcome these added complexities, specifically for those newer to the field of MSI.
Collapse
Affiliation(s)
- Russell R Kibbe
- Department of Chemistry, FTMS Laboratory for Human Health Research, North Carolina State University, Raleigh, North Carolina, USA
| | - David C Muddiman
- Department of Chemistry, FTMS Laboratory for Human Health Research, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
4
|
Palomino TV, Muddiman DC. Achieving Cross-Ring Fragmentation of N-Linked Glycans by IR-MALDESI. J Am Soc Mass Spectrom 2024; 35:166-171. [PMID: 38113534 DOI: 10.1021/jasms.3c00283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
Glycans are complex structures that require MS/MS for detailed structural elucidation. Incorporating metals can provide more structural information by inhibiting glycosidic cleavage and enhancing cross-ring fragmentation. A direct analysis was performed using lithium doping and IR-MALDESI to induce cross-ring fragmentation of glycans. The protonated and lithiated versions of the two glycans were isolated and subjected to HCD. For protonated glycans, only glycosidic cleavages were observed. Using lithium doping, MS/MS consisted of abundant cross-ring fragments. Seventeen cross-ring fragments were detected across both glycans using lithium-doped ESI. This is the first incorporation of metal doping in IR-MALDESI to achieve cross-ring fragments in MS/MS analysis.
Collapse
Affiliation(s)
- Tana V Palomino
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
5
|
Knizner KT, Eisenberg SM, Muddiman DC. Prototyping an ionization source for non-engineers. J Mass Spectrom 2024; 59:e4995. [PMID: 38129178 DOI: 10.1002/jms.4995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/22/2023] [Accepted: 11/27/2023] [Indexed: 12/23/2023]
Abstract
Novel mass spectrometry (MS) based analytical platforms have enabled scientists to detect and quantify molecules within biological and environmental samples more accurately. Novel MS instrumentation starts as a prototype and, after years of development, can become a commercial product to be used by the larger MS community. Without the initial prototype, many MS-based instruments today would not be produced. Additionally, biotechnology companies are the main drivers for research, development, and production of novel instruments, but the tools for prototyping instrumentation have never been more accessible. Here, we present a tutorial on prototyping instrumentation through the case study of developing the Next Generation IR-MALDESI source to show that an engineering degree is not required to design and construct a prototype instrument with modern hardware and software. We discuss the prototyping process, the necessary skills required for efficient prototyping, and information about common hardware and software used within initial prototypes.
Collapse
Affiliation(s)
- Kevan T Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Seth M Eisenberg
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| |
Collapse
|
6
|
Joignant AN, Knizner KT, Xi Y, Muddiman DC. Evaluating the optimal tissue thickness for mass spectrometry imaging using infrared matrix-assisted laser desorption electrospray ionization. Rapid Commun Mass Spectrom 2023; 37:e9638. [PMID: 37817341 PMCID: PMC10881192 DOI: 10.1002/rcm.9638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 08/26/2023] [Accepted: 08/26/2023] [Indexed: 10/12/2023]
Abstract
RATIONALE Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) utilizes a 2970 nm mid-IR laser to desorb samples with depth resolutions (Z) on the order of micrometers. Conventionally, 5-20 μm thick tissue sections are used to characterize different applications of the IR-MALDESI source, but an optimal thickness has not been systematically investigated. METHODS Mouse liver was sectioned to various thicknesses and analyzed using IR-MALDESI mass spectrometry imaging (MSI). Height profiles of tissue sections of various cryosectioned thicknesses were acquired to affirm tissue thickness. Tissue sections of each thickness were measured using a Keyence microscope. Paraffin wax was cryosectioned, mounted on microscope slides, and measured using a chromatic confocal sensor system to determine the cryostat sectioning accuracy. RESULTS Analyzing sectioned tissues at higher thickness (>10 μm) leads to lower ion abundance, a decrease in signal over long analysis times, and more frequent instrument cleaning. Additionally, increasing tissue thickness above the optimum (7 μm) does not result in a significant increase in lipid annotations. CONCLUSIONS This work defines an optimal sample thickness for IR-MALDESI-MSI and demonstrates the utility of optimizing tissue thickness for MSI platforms of comparable Z resolution.
Collapse
Affiliation(s)
- Alena N. Joignant
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Kevan T. Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Ying Xi
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
7
|
Wang MF, Ritter MM, Kullman SW, Muddiman DC. Comparative analysis of sucrose-embedding for whole-body zebrafish MSI by IR-MALDESI. Anal Bioanal Chem 2023; 415:6389-6398. [PMID: 37640826 DOI: 10.1007/s00216-023-04914-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 08/13/2023] [Accepted: 08/15/2023] [Indexed: 08/31/2023]
Abstract
Infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI) conventionally utilizes fresh-frozen biological tissues with an ice matrix to improve the detection of analytes. Sucrose-embedding with paraformaldehyde fixation has demonstrated feasibility as an alternative matrix for analysis by IR-MALDESI by preserving tissue features and enhancing ionization of lipids. However, investigating multi-organ systems provides broader context for a biological study and can elucidate more information about a disease state as opposed to a single organ. Danio rerio, or zebrafish, are model organisms for various disease states and can be imaged as a multi-organ sample to analyze morphological and metabolomic preservation as a result of sample preparation. Herein, whole-body zebrafish were imaged to compare sucrose-embedding with paraformaldehyde fixation against conventional fresh-frozen sample preparation. Serial sections were analyzed with and without an ice matrix to evaluate if sucrose functions as an alternative energy-absorbing matrix for IR-MALDESI applications across whole-body tissues. The resulting four conditions were compared in terms of total putative lipid annotations and category diversity, coverage across the entire m/z range, and ion abundance. Ultimately, sucrose-embedded zebrafish had an increase in putative lipid annotations for the combination of putative annotations with and without the application of an ice matrix relative to fresh-frozen tissues which require the application of an ice matrix. Upon the use of an ice matrix, a greater number of high mass putative lipid annotations (e.g., glycerophospholipids, glycerolipids, and sphingolipids) were identified. Conversely, without an ice matrix, sucrose-embedded sections elucidated more putative annotations in lower molecular weight lipids, including fatty acyls and sterol lipids. Similar to the mouse brain model, sucrose-embedding increased putative lipid annotation and abundance for whole-body zebrafish.
Collapse
Affiliation(s)
- Mary F Wang
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Morgan M Ritter
- Department of Biological Sciences, North Carolina State University, Raleigh, NC, USA
- Toxicology Program, North Carolina State University, Raleigh, NC, USA
| | - Seth W Kullman
- Department of Biological Sciences, North Carolina State University, Raleigh, NC, USA
- Toxicology Program, North Carolina State University, Raleigh, NC, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
8
|
Eisenberg SM, Knizner KT, Muddiman DC. Metabolite Annotation Confidence Score (MACS): A Novel MSI Identification Scoring Tool. J Am Soc Mass Spectrom 2023; 34:2222-2231. [PMID: 37606933 DOI: 10.1021/jasms.3c00178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/23/2023]
Abstract
Mass spectrometry imaging (MSI) is an analytical technique capable of measuring and visualizing the spatial distribution of thousands of ions across a sample. Measured ions can be putatively identified and annotated by comparing their mass-to-charge ratio (m/z) to a database of known compounds. For high-resolution, accurate mass (HRAM) imaging data sets, this is commonly performed by the annotation platform METASPACE. Annotations are reported with a metabolite-signal-match (MSM) score as a measure of the annotation's confidence level. However, the MSM scores reported by METASPACE often do not reflect a reasonable confidence level of an annotation and are not assigned consistently. The metabolite annotation confidence score (MACS) is an alternative scoring system based on fundamental mass spectrometry imaging metrics (mass measurement accuracy, spectral accuracy, and spatial distribution) to generate values that reflect the confidence of a specific annotation in HRAM-MSI data sets. Herein, the MACS system is characterized and compared to MSM scores from ions annotated by METASPACE.
Collapse
Affiliation(s)
- Seth M Eisenberg
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Kevan T Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
9
|
Joignant AN, Ritter MM, Knizner KT, Garrard KP, Kullman SW, Muddiman DC. Maximized Spatial Information and Minimized Acquisition Time of Top-Hat IR-MALDESI-MSI of Zebrafish Using Nested Regions of Interest (nROIs). J Am Soc Mass Spectrom 2023; 34:2043-2050. [PMID: 37526449 DOI: 10.1021/jasms.3c00210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
Increasing the spatial resolution of a mass spectrometry imaging (MSI) method results in a more defined heatmap of the spatial distribution of molecules across a sample, but it is also associated with the disadvantage of increased acquisition time. Decreasing the area of the region of interest to achieve shorter durations results in the loss of potentially valuable information in larger specimens. This work presents a novel MSI method to reduce the time of MSI data acquisition with variable step size imaging: nested regions of interest (nROIs). Using nROIs, a small ROI may be imaged at a higher spatial resolution while nested inside a lower-spatial-resolution peripheral ROI. This conserves the maximal spatial and chemical information generated from target regions while also decreasing the necessary acquisition time. In this work, the nROI method was characterized on mouse liver and applied to top-hat MSI of zebrafish using a novel optical train, which resulted in a significant improvement in both acquisition time and spatial detail of the zebrafish. The nROI method can be employed with any step size pairing and adapted to any method in which the acquisition time of larger high-resolution ROIs poses a practical challenge.
Collapse
Affiliation(s)
- Alena N Joignant
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Morgan M Ritter
- Toxicology Program, Department of Biological Sciences, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Kevan T Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Seth W Kullman
- Toxicology Program, Department of Biological Sciences, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
10
|
Samal J, Palomino TV, Chen J, Muddiman DC, Segura T. Enhanced Detection of Charged N-Glycans in the Brain by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometric Imaging. Anal Chem 2023; 95:10913-10920. [PMID: 37427925 PMCID: PMC10640919 DOI: 10.1021/acs.analchem.3c00494] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/11/2023]
Abstract
N-linked glycosylation represents a structurally diverse, complex, co- and posttranslational protein modification that bridges metabolism and cellular signaling. Consequently, aberrant protein glycosylation is a hallmark of most pathological scenarios. Due to their complex nature and non-template-driven synthesis, the analysis of glycans is faced with several challenges, underlining the need for new and improved analytical technologies. Spatial profiling of N-glycans through direct imaging on tissue sections reveals the regio-specific and/or disease pathology correlating tissue N-glycans that serve as a disease glycoprint for diagnosis. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a soft hybrid ionization technique that has been used for diverse mass spectrometry imaging (MSI) applications. Here, we report the first spatial analysis of the brain N-linked glycans by IR-MALDESI MSI, leading to a significant increase in the detection of the brain N-sialoglycans. A formalin-fixed paraffin-embedded mouse brain tissue was analyzed in negative ionization mode after tissue washing, antigen retrieval, and pneumatic application of PNGase F for enzymatic digestion of N-linked glycans. We report a comparative analysis of section thickness on the N-glycan detection using IR-MALDESI. One hundred thirty-six unique N-linked glycans were confidently identified in the brain tissue (with an additional 132 unique N-glycans, not reported in GlyConnect), where more than 50% contained sialic acid residues, which is approximately 3-fold higher than the previous reports. This work demonstrates the first application of IR-MALDESI in N-linked glycan imaging of the brain tissue, leading to a 2.5-fold increase in the in situ total brain N-glycan detection compared to the current gold standard of positive-mode matrix-assisted laser desorption/ionization mass spectrometry imaging. This is also the first report of the application of the MSI toward the identification of sulfoglycans in the rodent brain. Overall, IR-MALDESI-MSI presents a sensitive glycan detection platform to identify tissue-specific and/or disease-specific glycosignature in the brain while preserving the sialoglycans without any chemical derivatization.
Collapse
Affiliation(s)
- Juhi Samal
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708-0274, United States
| | - Tana V Palomino
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695-7001, United States
| | - Judy Chen
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708-0274, United States
| | - David C Muddiman
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695-7001, United States
| | - Tatiana Segura
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708-0274, United States
| |
Collapse
|
11
|
Xi Y, Knizner KT, Garrard KP, Muddiman DC. Automatic z-Axis Correction for IR-MALDESI Mass Spectrometry Imaging of Uneven Surfaces. J Am Soc Mass Spectrom 2023. [PMID: 37306946 DOI: 10.1021/jasms.3c00151] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Two-dimensional mass spectrometry imaging (2D MSI) experiments mainly involve samples with a flat surface and constant thickness, but some samples are challenging to section due to the texture and topography. Herein, we present an MSI method that automatically corrects for discernible height differences across surfaces during imaging experiments. A chromatic confocal sensor was incorporated into the infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) system to measure the sample surface height at the location of each analytical scan. The height profile is subsequently used for adjusting the z-axis position of the sample during MSI data acquisition. We evaluated this method using a tilted mouse liver section and an unsectioned Prilosec tablet due to their exterior quasi-homogeneity and height differences of approximately ∼250 μm. MSI with automatic z-axis correction showed consistent ablated spot sizes and shapes, revealing the measured ion spatial distribution across a mouse liver section and a Prilosec tablet. Conversely, irregular spots and reduced signals with large variability were observed when no z-axis correction was applied.
Collapse
Affiliation(s)
- Ying Xi
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Kevan T Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
- Precision Engineering Consortium, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
12
|
Abstract
Sialic acids play several roles in both physiological and pathological processes; however, due to their labile nature, they are difficult to analyze using mass spectrometry. Previous work has shown that infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is able to detect intact sialylated N-linked glycans without the use of chemical derivatization. In this work, we describe a new rule that can predict the number of sialic acids on a glycan. Formalin-fixed paraffin-embedded human kidney tissue was prepared using previously established methods and analyzed using IR-MALDESI in negative-ion mode mass spectrometry. Using the experimental isotopic distribution of a detected glycan, we can predict the number of sialic acids on the glycan; #sialic acids is equal to the charge state minus the number of chlorine adducts, or z - #Cl-. This new rule grants confident glycan annotations and compositions beyond accurate mass measurements, thereby further improving the capability of IR-MALDESI to study sialylated N-linked glycans within biological tissues.
Collapse
Affiliation(s)
- Tana V Palomino
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, USA
| |
Collapse
|
13
|
Eisenberg SM, Knizner KT, Muddiman DC. Development of an object-based image analysis tool for mass spectrometry imaging ion classification. Anal Bioanal Chem 2023:10.1007/s00216-023-04764-x. [PMID: 37222794 DOI: 10.1007/s00216-023-04764-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 05/10/2023] [Accepted: 05/15/2023] [Indexed: 05/25/2023]
Abstract
Mass spectrometry imaging (MSI) is an analytical technique that can detect and visualize thousands of m/z values resolved in two- and three-dimensional space. These m/z values lead to hundreds of molecular annotations, including on-tissue and background ions. Discrimination of sample-related analytes from ambient ions conventionally involves manual investigation of each ion heatmap, which requires significant researcher time and effort (for a single tissue image, it can take an hour to determine on-tissue and off-tissue species). Moreover, manual investigation lends itself to subjectivity. Herein, we present the utility of an ion classification tool (ICT) developed using object-based image analysis in MATLAB. The ICT functions by segmenting ion heatmap images into on-tissue and off-tissue objects through binary conversion. The binary images are analyzed and within seconds used to classify the ions as on-tissue or background using a binning approach based on the number of detected objects. In a representative dataset with 50 randomly selected annotations, the ICT was able to accurately classify 45/50 ions as on-tissue or background.
Collapse
Affiliation(s)
- Seth M Eisenberg
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Kevan T Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
14
|
Wang MF, Sohn AL, Samal J, Erning K, Segura T, Muddiman DC. Lipidomic Analysis of Mouse Brain to Evaluate the Efficacy and Preservation of Different Tissue Preparatory Techniques by IR-MALDESI-MSI. J Am Soc Mass Spectrom 2023; 34:869-877. [PMID: 36988291 DOI: 10.1021/jasms.2c00353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Numerous preparatory methods have been developed to preserve the cellular and structural integrity of various biological tissues for different -omics studies. Herein, two preparatory methods for mass spectrometry imaging (MSI) were evaluated, fresh-frozen and sucrose-embedded, paraformaldehyde (PFA) fixed, in terms of ion abundance, putative lipid identifications, and preservation of analyte spatial distributions. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI)-MSI was utilized to compare the preparatory methods of interest with and without the use of the conventional ice matrix. There were 2.5-fold and 1.6-fold more lipid species putatively identified in positive- and negative-ion modes, respectively, for sucrose-embedded, PFA-fixed tissues without an ice matrix relative to the current IR-MALDESI-MSI gold-standard, fresh-frozen tissue preparation with an exogenous ice matrix. Furthermore, sucrose-embedded tissues demonstrated improved spatial distribution of ions resulting from the cryo-protective property of sucrose and paraformaldehyde fixation. Evidence from these investigations supports sucrose-embedding without ice matrix as an alternative preparatory technique for IR-MALDESI-MSI.
Collapse
Affiliation(s)
- Mary F Wang
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Alexandria L Sohn
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Juhi Samal
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Kevin Erning
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Tatiana Segura
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - David C Muddiman
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
- Molecular Education, Technology and Research Innovation Center, North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
15
|
Joignant AN, Xi Y, Muddiman DC. Impact of wavelength and spot size on laser depth of focus: Considerations for mass spectrometry imaging of non-flat samples. J Mass Spectrom 2023; 58:e4914. [PMID: 36916474 DOI: 10.1002/jms.4914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 02/09/2023] [Accepted: 02/19/2023] [Indexed: 06/18/2023]
Abstract
Biospecimens with nearly flat surfaces on a flat stage are typically required for laser-based mass spectrometry imaging (MSI) techniques. However, sampling stages are rarely perfectly level, and accounting for this and the need to accommodate non-flat samples requires a deeper understanding of the laser beam depth of focus. In ablation-based MSI methods, a laser is focused on top of the sample surface, ensuring that the sample is at the focal point or remains within depth of focus. In general, the depth of focus of a given laser is related to the beam quality (M2 ) and the wavelength (λ). However, because laser is applied on a biological sample, other variables can also impact the depth of focus, which could affect the robustness of the MSI techniques for diverse sample types. When the height of a sample ranges outside of the depth of focus, ablated area and the corresponding ion abundances may vary as well, increasing the variability of results. In this tutorial, we examine the parameters and equations that describe the depth of focus of a Gaussian laser beam. Additionally, we describe several approaches that account for surface roughness exceeding the depth of focus of the laser.
Collapse
Affiliation(s)
- Alena N Joignant
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - Ying Xi
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
16
|
Muddiman DC. Correction to "On the importance of color in mass spectrometry imaging". J Mass Spectrom 2023; 58:e4921. [PMID: 37100432 DOI: 10.1002/jms.4921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Affiliation(s)
- David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA
| |
Collapse
|
17
|
Muddiman DC. Correction to "Time of acquisition and high spatial resolution mass spectrometry imaging". J Mass Spectrom 2023; 58:e4922. [PMID: 37100431 DOI: 10.1002/jms.4922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Affiliation(s)
- David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA
| |
Collapse
|
18
|
Kibbe RR, Muddiman DC. Achieving Sub-Parts-per-Million Mass Measurement Accuracy on an Orbitrap Mass Spectrometry Imaging Platform without Automatic Gain Control. J Am Soc Mass Spectrom 2023. [PMID: 37096916 DOI: 10.1021/jasms.3c00004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The collection of profile data is standard practice within the field of mass spectrometry (MS). However, profile data collection often results in large data files that require extensive processing times, especially in mass spectrometry imaging (MSI) studies where thousands of high-resolution scans are recorded. Natively collecting centroid MS data is an alternative that effectively reduces both the resulting file size and the data processing time. Herein, high-resolution accurate mass (HRAM) Orbitrap MSI data on mouse liver tissue sections without automatic gain control (AGC) were natively collected in both profile and centroid modes and compared based on the file size and processing time. Additionally, centroid data were evaluated against the profile data with regard to the spectra integrity, mass measurement accuracy (MMA), and the number of lipid annotations to ensure that centroid data did not compromise the data quality. For both native and postacquisition centroided data, the variation in mass measurement accuracy decreased relative to the profile data collection. Furthermore, centroid data collection increased the number of METASPACE database annotations indicating higher sensitivity and greater accuracy for lipid annotation compared to native profile data collection. Profile MSI data was shown to have a higher likelihood of false positive identifications due to an increased number of data points on either side of the peaks, whereas the same trend was not observed in data collected in native centroid data collection. This publication explores and explains the importance in properly centroiding MSI data, either natively or by adequate centroiding methods, to obtain the most accurate information and come to the best conclusions. These data support that natively collecting centroid data significantly improves MMA to sub-ppm levels without AGC and reduces false positive annotations.
Collapse
Affiliation(s)
- Russell R Kibbe
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
19
|
Wang MF, Joignant AN, Sohn AL, Garrard KP, Muddiman DC. Time of acquisition and high spatial resolution mass spectrometry imaging. J Mass Spectrom 2023; 58:e4911. [PMID: 36916455 DOI: 10.1002/jms.4911] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 01/27/2023] [Accepted: 02/09/2023] [Indexed: 06/18/2023]
Abstract
The field of mass spectrometry imaging (MSI) is constantly evolving to analyze a diverse array of biological systems. A common goal is the need to resolve cellular and subcellular heterogeneity with high spatial resolution. As the field continues to progress towards high spatial resolution, other parameters must be considered when developing a practical method. Here, we discuss the impacts of high spatial resolution on the time of acquisition and the associated implications they have on an MSI analysis (e.g., area of the region of interest). This work presents a brief tutorial serving to evaluate high spatial resolution MSI relative to time of acquisition and data file size.
Collapse
Affiliation(s)
- Mary F Wang
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - Alena N Joignant
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - Alexandria L Sohn
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology and Research Innovation Center, North Carolina State University, Raleigh, North Carolina, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology and Research Innovation Center, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
20
|
Holman SW, Langley GJ, Muddiman DC, Novak-Mitchell C. RCM protocols: improving reproducibility in the field of mass spectrometry. Rapid Commun Mass Spectrom 2023; 38 Suppl 1:e9677. [PMID: 38169149 DOI: 10.1002/rcm.9677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Affiliation(s)
- Stephen W Holman
- Chemical Development, Pharmaceutical Technology & Development, Operations, AstraZeneca, Macclesfield, UK
| | - G John Langley
- Chemistry, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | | |
Collapse
|
21
|
Xi Y, Sohn AL, Joignant AN, Cologna SM, Prentice BM, Muddiman DC. SMART: A data reporting standard for mass spectrometry imaging. J Mass Spectrom 2023; 58:e4904. [PMID: 36740651 PMCID: PMC10078510 DOI: 10.1002/jms.4904] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/16/2023] [Accepted: 01/19/2023] [Indexed: 06/18/2023]
Abstract
Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra- and inter-laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data.
Collapse
Affiliation(s)
- Ying Xi
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Alexandria L. Sohn
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Alena N. Joignant
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | | | | | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNorth CarolinaUSA
| |
Collapse
|
22
|
Bai H, Manni JG, Muddiman DC. Transforming a Mid-infrared Laser Profile from Gaussian to a Top-Hat with a Diffractive Optical Element for Mass Spectrometry Imaging. J Am Soc Mass Spectrom 2023; 34:10-16. [PMID: 36542595 PMCID: PMC9975536 DOI: 10.1021/jasms.2c00203] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Many mass spectrometry imaging (MSI) applications such as infrared matrix-assisted electrospray ionization (IR-MALDESI) employ an infrared (IR) laser with a Gaussian profile where laser irradiance is highest in the center and decreases exponentially. To enable full ablation of a square region of interest, oversampling is often needed, which results in nonuniform ablation and leads to decreased image quality. A diffractive optical element (DOE) was integrated into the optical path to generate homogeneous intensity distributions while maintaining laser energy above the ablation threshold, to enable complete sample removal from laser pulses without oversampling. 2D and 3D imaging with the DOE inserted show clear and sharp ablation patterns with satisfactory biological signals gained. Further improvements will optimize the beam profile and generate a square top-hat laser beam for MSI application at higher spatial resolution.
Collapse
Affiliation(s)
- Hongxia Bai
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | | | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695 USA
| |
Collapse
|
23
|
Arciniega C, Garrard KP, Guymon JP, Manni JG, Apffel A, Fjeldsted JC, Muddiman DC. Quasi-continuous infrared matrix-assisted laser desorption electrospray ionization source coupled to a quadrupole time-of-flight mass spectrometer for direct analysis from well plates. J Mass Spectrom 2023; 58:e4902. [PMID: 36694312 PMCID: PMC9944147 DOI: 10.1002/jms.4902] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 12/03/2022] [Accepted: 01/07/2023] [Indexed: 06/17/2023]
Abstract
High-throughput screening (HTS) is a technique mostly used by pharmaceutical companies to rapidly screen multiple libraries of compounds to find drug hits with biological or pharmaceutical activity. Mass spectrometry (MS) has become a popular option for HTS given that it can simultaneously resolve hundreds to thousands of compounds without additional chemical derivatization. For this application, it is convenient to do direct analysis from well plates. Herein, we present the development of an infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source coupled directly to an Agilent 6545 for direct analysis from well plates. The source is coupled to a quadrupole time-of-flight (Q-TOF) mass spectrometer to take advantage of the high acquisition rates without sacrificing resolving power as required with Orbitrap or Fourier-transform ion cyclotron resonance (FTICR) instruments. The laser used for this source operates at 100 Hz, firing 1 pulse-per-burst, and delivers around 0.7 mJ per pulse. Continuously firing this laser for an extended duration makes it a quasi-continuous ionization source. Additionally, a metal capillary was constructed to extend the inlet of the mass spectrometer, increase desolvation of electrospray charged droplets, improve ion transmission, and increase sensitivity. Its efficiency was compared with the conventional dielectric glass capillary by measured signal and demonstrated that the metal capillary increased ionization efficiency due to its more uniformly distributed temperature gradient. Finally, we present the functionality of the source by analyzing tune mix directly from well plates. This source is a proof of concept for HTS applications using IR-MALDESI coupled to a different MS platform.
Collapse
Affiliation(s)
- Cristina Arciniega
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNC27695USA
| | - Kenneth P. Garrard
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNC27695USA
- Precision Engineering ConsortiumNorth Carolina State UniversityRaleighNC27695USA
- Molecular Education, Technology and Research Innovation Center (METRIC)North Carolina State UniversityRaleighNC27695USA
| | - Jacob P. Guymon
- Precision Engineering ConsortiumNorth Carolina State UniversityRaleighNC27695USA
| | | | | | | | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNC27695USA
- Molecular Education, Technology and Research Innovation Center (METRIC)North Carolina State UniversityRaleighNC27695USA
| |
Collapse
|
24
|
Caleb Bagley M, Garrard KP, Muddiman DC. The development and application of matrix assisted laser desorption electrospray ionization: The teenage years. Mass Spectrom Rev 2023; 42:35-66. [PMID: 34028071 DOI: 10.1002/mas.21696] [Citation(s) in RCA: 31] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/20/2021] [Accepted: 04/21/2021] [Indexed: 05/24/2023]
Abstract
In the past 15 years, ambient ionization techniques have witnessed a significant incursion into the field of mass spectrometry imaging, demonstrating their ability to provide complementary information to matrix-assisted laser desorption ionization. Matrix-assisted laser desorption electrospray ionization is one such technique that has evolved since its first demonstrations with ultraviolet lasers coupled to Fourier transform-ion cyclotron resonance mass spectrometers to extensive use with infrared lasers coupled to orbitrap-based mass spectrometers. Concurrently, there have been transformative developments of this imaging platform due to the high level of control the principal group has retained over the laser technology, data acquisition software (RastirX), instrument communication, and image processing software (MSiReader). This review will discuss the developments of MALDESI since its first laboratory demonstration in 2005 to the most recent advances in 2021.
Collapse
Affiliation(s)
- Michael Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- The Precision Engineering Consortium, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina, USA
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
25
|
Joignant AN, Bai H, Manni JG, Muddiman DC. Improved spatial resolution of infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging using a reflective objective. Rapid Commun Mass Spectrom 2022; 36:e9392. [PMID: 36057935 PMCID: PMC9643617 DOI: 10.1002/rcm.9392] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 08/31/2022] [Accepted: 09/01/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE The level of visual detail of a mass spectrometry image is dependent on the spatial resolution with which it is acquired, which is largely determined by the focal diameter in infrared laser ablation-based techniques. While the use of mid-IR light for mass spectrometry imaging (MSI) has advantages, it results in a relatively large focal diameter and spatial resolution. The continual advancement of infrared matrix-assisted electrospray ionization (IR-MALDESI) for MSI warranted novel methods to decrease laser ablation areas and thus improve spatial resolution. METHODS In this work, a Schwarzschild-like reflective objective was incorporated into the novel NextGen IR-MALDESI source and characterized on both burn paper and mammalian tissue using an ice matrix. Ablation areas, mass spectra, and annotations obtained using the objective were compared against the current optical train on the NextGen system without modification. RESULTS The effective resolution was determined to be 55 μm by decreasing the step size until oversampling was observed. Use of the objective improved the spatial resolution by a factor of three as compared against the focus lens. CONCLUSIONS A Schwarzschild-like reflective objective was successfully incorporated into the NextGen source and characterized on mammalian tissue using an ice matrix. The corresponding improvement in spatial resolution facilitates the future expansion of IR-MALDESI applications to include those that require fine structural detail.
Collapse
Affiliation(s)
- Alena N. Joignant
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNCUSA
| | - Hongxia Bai
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNCUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNCUSA
| | | | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNCUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNCUSA
| |
Collapse
|
26
|
Knizner KT, Kibbe RR, Garrard KP, Nuñez JR, Anderton CR, Muddiman DC. On the importance of color in mass spectrometry imaging. J Mass Spectrom 2022; 57:e4898. [PMID: 36463891 PMCID: PMC9944061 DOI: 10.1002/jms.4898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 11/07/2022] [Accepted: 11/17/2022] [Indexed: 05/12/2023]
Abstract
Mass spectrometry imaging (MSI) data visualization relies on heatmaps to show the spatial distribution and measured abundances of molecules within a sample. Nonuniform color gradients such as jet are still commonly used to visualize MSI data, increasing the probability of data misinterpretation and false conclusions. Also, the use of nonuniform color gradients and the combination of hues used in common colormaps make it challenging for people with color vision deficiencies (CVDs) to visualize and accurately interpret data. Here we present best practices for choosing a colormap to accurately display MSI data, improve readability, and accommodate all CVDs. We also provide other resources on the misuse of color in the scientific field and resources on scientifically derived colormaps presented herein.
Collapse
Affiliation(s)
- Kevan T. Knizner
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Russell R. Kibbe
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Kenneth P. Garrard
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation Center (METRIC)North Carolina State UniversityRaleighNorth CarolinaUSA
- Precision Engineering ConsortiumNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Jamie R. Nuñez
- Earth and Biological Sciences DirectoratePacific Northwest National LaboratoryRichlandWashingtonUSA
| | - Christopher R. Anderton
- Earth and Biological Sciences DirectoratePacific Northwest National LaboratoryRichlandWashingtonUSA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation Center (METRIC)North Carolina State UniversityRaleighNorth CarolinaUSA
| |
Collapse
|
27
|
Joignant AN, Bai H, Guymon JP, Garrard KP, Pankow M, Muddiman DC. Developing transmission mode for infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging. Rapid Commun Mass Spectrom 2022; 36:e9386. [PMID: 36056474 PMCID: PMC9541130 DOI: 10.1002/rcm.9386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 08/27/2022] [Accepted: 08/27/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE The development and characterization of the novel NextGen infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source catalyzed new advancements in IR-MALDESI instrumentation, including the development of a new analysis geometry. METHODS A vertically oriented transmission mode (tm)-IR-MALDESI setup was developed and optimized on thawed mouse tissue. In addition, glycerol was introduced as an alternative energy-absorbing matrix for tm-IR-MALDESI because the new geometry does not currently allow for the formation of an ice matrix. The tm geom was evaluated against the optimized standard geometry for the NextGen source in reflection mode (rm). RESULTS It was found that tm-IR-MALDESI produces comparable results to rm-IR-MALDESI after optimization. The attempt to incorporate glycerol as an alternative matrix provided little improvement to tm-IR-MALDESI ion abundances. CONCLUSIONS This work has successfully demonstrated the adaptation of the NextGen IR-MALDESI source through the feasibility of tm-IR-MALDESI mass spectrometry imaging on mammalian tissue, expanding future biological applications of the method.
Collapse
Affiliation(s)
- Alena N. Joignant
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Hongxia Bai
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Jacob P. Guymon
- Precision Engineering Consortium, Department of Mechanical and Aerospace EngineeringNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Kenneth P. Garrard
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Precision Engineering Consortium, Department of Mechanical and Aerospace EngineeringNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Mark Pankow
- Precision Engineering Consortium, Department of Mechanical and Aerospace EngineeringNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation CenterNorth Carolina State UniversityRaleighNorth CarolinaUSA
| |
Collapse
|
28
|
Mellinger AL, Kibbe RR, Rabbani ZN, Meritet D, Muddiman DC, Gamcsik MP. Mapping glycine uptake and its metabolic conversion to glutathione in mouse mammary tumors using functional mass spectrometry imaging. Free Radic Biol Med 2022; 193:677-684. [PMID: 36402437 PMCID: PMC9737053 DOI: 10.1016/j.freeradbiomed.2022.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 11/08/2022] [Accepted: 11/08/2022] [Indexed: 11/18/2022]
Abstract
Although glutathione plays a key role in cancer cell viability and therapy response there is no clear trend in relating the level of this antioxidant to clinical stage, histological grade, or therapy response in patient tumors. The likely reason is that static levels of glutathione are not a good indicator of how a tissue deals with oxidative stress. A better indicator is the functional capacity of the tissue to maintain glutathione levels in response to this stress. However, there are few methods to assess glutathione metabolic function in tissue. We have developed a novel functional mass spectrometry imaging (fMSI) method that can map the variations in the conversion of glycine to glutathione metabolic activity across tumor tissue sections by tracking the fate of three glycine isotopologues administered in a timed sequence to tumor-bearing anesthetized mice. This fMSI method generates multiple time point kinetic data for substrate uptake and glutathione production from each spatial location in the tissue. As expected, the fMSI data shows glutathione metabolic activity varies across the murine 4T1 mammary tumor. Although glutathione levels are highest at the tumor periphery there are regions of high content but low metabolic activity. The timed infusion method also detects variations in delivery of the glycine isotopologues thereby providing a measure of tissue perfusion, including evidence of intermittent perfusion, that contributes to the observed differences in metabolic activity. We believe this new approach will be an asset to linking molecular content to tissue function.
Collapse
Affiliation(s)
- Allyson L Mellinger
- FTMS Laboratory for Human Health Research, Department of Chemistry, NC State University, 2700 Stinson Dr., Raleigh, NC, 27607, USA
| | - Russell R Kibbe
- FTMS Laboratory for Human Health Research, Department of Chemistry, NC State University, 2700 Stinson Dr., Raleigh, NC, 27607, USA
| | - Zahid N Rabbani
- UNC/NCSU Joint Department of Biomedical Engineering, 1840 Entrepreneur Drive, Raleigh, NC, 27695, USA
| | - Danielle Meritet
- Department of Population Health and Pathobiology, College of Veterinary Medicine, NC State University, Raleigh, NC, 27607, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, NC State University, 2700 Stinson Dr., Raleigh, NC, 27607, USA; Molecular Education, Technology and Research Innovation Center (METRIC), Raleigh, NC, 27695, USA
| | - Michael P Gamcsik
- UNC/NCSU Joint Department of Biomedical Engineering, 1840 Entrepreneur Drive, Raleigh, NC, 27695, USA.
| |
Collapse
|
29
|
Sohn AL, Ping L, Glass JD, Seyfried NT, Hector EC, Muddiman DC. Interrogating the Metabolomic Profile of Amyotrophic Lateral Sclerosis in the Post-Mortem Human Brain by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI) Mass Spectrometry Imaging (MSI). Metabolites 2022; 12:1096. [PMID: 36355179 PMCID: PMC9696666 DOI: 10.3390/metabo12111096] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 10/26/2022] [Accepted: 11/07/2022] [Indexed: 01/03/2024] Open
Abstract
Amyotrophic lateral sclerosis (ALS) is an idiopathic, fatal neurodegenerative disease characterized by progressive loss of motor function with an average survival time of 2-5 years after diagnosis. Due to the lack of signature biomarkers and heterogenous disease phenotypes, a definitive diagnosis of ALS can be challenging. Comprehensive investigation of this disease is imperative to discovering unique features to expedite the diagnostic process and improve diagnostic accuracy. Here, we present untargeted metabolomics by mass spectrometry imaging (MSI) for comparing sporadic ALS (sALS) and C9orf72 positive (C9Pos) post-mortem frontal cortex human brain tissues against a control cohort. The spatial distribution and relative abundance of metabolites were measured by infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI for association to biological pathways. Proteomic studies on the same patients were completed via LC-MS/MS in a previous study, and results were integrated with imaging metabolomics results to enhance the breadth of molecular coverage. Utilizing METASPACE annotation platform and MSiPeakfinder, nearly 300 metabolites were identified across the sixteen samples, where 25 were identified as dysregulated between disease cohorts. The dysregulated metabolites were further examined for their relevance to alanine, aspartate, and glutamate metabolism, glutathione metabolism, and arginine and proline metabolism. The dysregulated pathways discussed are consistent with reports from other ALS studies. To our knowledge, this work is the first of its kind, reporting on the investigation of ALS post-mortem human brain tissue analyzed by multiomic MSI.
Collapse
Affiliation(s)
- Alexandria L. Sohn
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Lingyan Ping
- Goizueta Alzheimer’s Disease Research Center, Emory University School of Medicine, Atlanta, GA 30322, USA
- Department of Neurology, Emory University School of Medicine, Atlanta, GA 30322, USA
- Department of Biochemistry, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Jonathan D. Glass
- Department of Neurology, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Nicholas T. Seyfried
- Goizueta Alzheimer’s Disease Research Center, Emory University School of Medicine, Atlanta, GA 30322, USA
- Department of Neurology, Emory University School of Medicine, Atlanta, GA 30322, USA
- Department of Biochemistry, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Emily C. Hector
- Department of Statistics, North Carolina State University, Raleigh, NC 27695, USA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
30
|
Knizner KT, Guymon JP, Garrard KP, Bouvrée G, Manni J, Hauschild JP, Strupat K, Fort KL, Earley L, Wouters ER, Pu F, Radosevich AJ, Elsen NL, Williams JD, Pankow MR, Muddiman DC. Next-Generation Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Source for Mass Spectrometry Imaging and High-Throughput Screening. J Am Soc Mass Spectrom 2022; 33:2070-2077. [PMID: 36173393 PMCID: PMC9944128 DOI: 10.1021/jasms.2c00178] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a hybrid, ambient ionization source that combines the advantages of electrospray ionization and matrix-assisted laser desorption/ionization, making it a versatile tool for both high-throughput screening (HTS) and mass spectrometry imaging (MSI) studies. To expand the capabilities of the IR-MALDESI source, an entirely new architecture was designed to overcome the key limitations of the previous source. This next-generation (NextGen) IR-MALDESI source features a vertically mounted IR-laser, a planar translation stage with computerized sample height control, an aluminum enclosure, and a novel mass spectrometer interface plate. The NextGen IR-MALDESI source has improved user-friendliness, improved overall versatility, and can be coupled to numerous Orbitrap mass spectrometers to accommodate more research laboratories. In this work, we highlight the benefits of the NextGen IR-MALDESI source as an improved platform for MSI and direct analysis. We also optimize the NextGen MALDESI source component geometries to increase target ion abundances over a wide m/z range. Finally, documentation is provided for each NextGen IR-MALDESI part so that it can be replicated and incorporated into any lab space.
Collapse
Affiliation(s)
- Kevan T. Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Jacob P. Guymon
- Precision Engineering Consortium, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh 27695, NC, USA
| | - Kenneth P. Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
- Precision Engineering Consortium, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh 27695, NC, USA
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| | - Guy Bouvrée
- GB Conseil & Services, 77170 Brie Comte Robert, France
| | | | | | - Kerstin Strupat
- Thermo Fisher Scientific (Bremen) GmbH, 28199 Bremen, Germany
| | - Kyle L. Fort
- Thermo Fisher Scientific (Bremen) GmbH, 28199 Bremen, Germany
| | - Lee Earley
- Thermo Fisher Scientific, San Jose, CA 95134, USA
| | | | - Fan Pu
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, IL 60064, USA
| | - Andrew J. Radosevich
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, IL 60064, USA
| | - Nathaniel L. Elsen
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, IL 60064, USA
| | - Jon D. Williams
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, IL 60064, USA
| | - Mark R. Pankow
- Precision Engineering Consortium, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh 27695, NC, USA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
31
|
Muddiman DC. Editors of the Journal of Mass Spectrometry Reinvigorate and Expand Mass Spectrometry Tutorials. J Mass Spectrom 2022; 57:e4889. [PMID: 36241379 DOI: 10.1002/jms.4889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
|
32
|
Kibbe RR, Mellinger AL, Muddiman DC. Novel matrix strategies for improved ionization and spatial resolution using IR-MALDESI mass spectrometry imaging. J Mass Spectrom 2022; 57:e4875. [PMID: 35900350 PMCID: PMC9541679 DOI: 10.1002/jms.4875] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 07/12/2022] [Accepted: 07/15/2022] [Indexed: 05/10/2023]
Abstract
In mass spectrometry imaging (MSI) applications of infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI), an exogenous ice layer is the gold standard for an energy-absorbing matrix. However, the formation of the ice matrix requires additional time and instrument hardware, so glycerol was investigated herein as an alternative to the ice matrix to potentially improve spatial resolution and ionization, while decreasing experiment time. Glycerol solutions of varying concentrations were sprayed over top of rat liver tissue sections for analysis by IR-MALDESI and compared to the typical ice matrix condition. Additionally, we tested if combining the ice matrix and glycerol matrix would further improve analyses. Matrix conditions were evaluated by comparing ion abundance of six lipid species, the laser ablation spot diameter, and number of METASPACE annotations. The ion abundances were also normalized to the volume of tissue ablated to correct for lower abundance values due to less ablated tissue. It was observed that utilizing a 50% glycerol matrix without ice provides improved spatial resolution with lipid abundances and annotations comparable to the ice matrix standard, while decreasing the time required to complete an IR-MALDESI tissue imaging experiment.
Collapse
Affiliation(s)
- Russell R. Kibbe
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Allyson L. Mellinger
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation Center (METRIC)North Carolina State UniversityRaleighNorth CarolinaUSA
| |
Collapse
|
33
|
Wu Y, Wong CW, Chiles EN, Mellinger AL, Bae H, Jung S, Peterson T, Wang J, Negrete M, Huang Q, Wang L, Jang C, Muddiman DC, Su X, Williamson I, Shen X. Glycerate from intestinal fructose metabolism induces islet cell damage and glucose intolerance. Cell Metab 2022; 34:1042-1053.e6. [PMID: 35688154 PMCID: PMC9897509 DOI: 10.1016/j.cmet.2022.05.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 12/21/2021] [Accepted: 05/18/2022] [Indexed: 02/06/2023]
Abstract
Dietary fructose, especially in the context of a high-fat western diet, has been linked to type 2 diabetes. Although the effect of fructose on liver metabolism has been extensively studied, a significant portion of the fructose is first metabolized in the small intestine. Here, we report that dietary fat enhances intestinal fructose metabolism, which releases glycerate into the blood. Chronic high systemic glycerate levels induce glucose intolerance by slowly damaging pancreatic islet cells and reducing islet sizes. Our findings provide a link between dietary fructose and diabetes that is modulated by dietary fat.
Collapse
Affiliation(s)
- Yanru Wu
- Department of Prosthodontics, School and Hospital of Stomatology, Wuhan University, Wuhan, Hubei 430079, China; Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA
| | - Chi Wut Wong
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA; Department of Pharmacology & Cancer Biology, Duke University Medical Center, Durham, NC 27710, USA
| | - Eric N Chiles
- Metabolomics Shared Resource, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ 08903, USA
| | - Allyson L Mellinger
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Hosung Bae
- Department of Biological Chemistry, University of California, Irvine, Irvine, CA 92697, USA
| | - Sunhee Jung
- Department of Biological Chemistry, University of California, Irvine, Irvine, CA 92697, USA
| | - Ted Peterson
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA
| | - Jamie Wang
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA
| | - Marcos Negrete
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA
| | - Qiang Huang
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA; Department of Pediatric Surgery, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shanxi 710004, China
| | - Lihua Wang
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA
| | - Cholsoon Jang
- Department of Biological Chemistry, University of California, Irvine, Irvine, CA 92697, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA; Molecular Education, Technology and Research Innovation Center, North Carolina State University, Raleigh, NC 27695, USA
| | - Xiaoyang Su
- Metabolomics Shared Resource, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ 08903, USA; Department of Medicine, Robert Wood Johnson Medical School, Rutgers University, New Brunswick, NJ 08901, USA
| | - Ian Williamson
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA; Gastroenterology Division, Department of Medicine, Duke University, Durham, NC 27710, USA.
| | - Xiling Shen
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA; Terasaki Institute for Biomedical Innovation, Los Angeles, CA 90024, USA.
| |
Collapse
|
34
|
Pace CL, Garrard KP, Muddiman DC. Sequential paired covariance for improved visualization of mass spectrometry imaging datasets. J Mass Spectrom 2022; 57:e4872. [PMID: 35734788 PMCID: PMC9287032 DOI: 10.1002/jms.4872] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 05/02/2022] [Accepted: 06/09/2022] [Indexed: 05/25/2023]
Abstract
Untargeted analyses in mass spectrometry imaging produce hundreds of ion images representing spatial distributions of biomolecules in biological tissues. Due to the large diversity of ions detected in untargeted analyses, normalization standards are often difficult to implement to account for pixel-to-pixel variability in imaging studies. Many normalization strategies exist to account for this variability, but they largely do not improve image quality. In this study, we present a new approach for improving image quality and visualization of tissue features by application of sequential paired covariance (SPC). This approach was demonstrated using previously published tissue datasets such as rat brain and human prostate with different biomolecules like metabolites and N-linked glycans. Data transformation by SPC improved ion images resulting in increased smoothing of biological features compared with commonly used normalization approaches.
Collapse
Affiliation(s)
- Crystal L. Pace
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Kenneth P. Garrard
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- The Precision Engineering ConsortiumNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation Center (METRIC)North Carolina State UniversityRaleighNorth CarolinaUSA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation Center (METRIC)North Carolina State UniversityRaleighNorth CarolinaUSA
| |
Collapse
|
35
|
Abstract
Most mass spectrometry imaging (MSI) methods provide a molecular map of tissue content but little information on tissue function. Mapping tissue function is possible using several well-known examples of "functional imaging" such as positron emission tomography and functional magnetic resonance imaging that can provide the spatial distribution of time-dependent biological processes. These functional imaging methods represent the net output of molecular networks influenced by local tissue environments that are difficult to predict from molecular/cellular content alone. However, for decades, MSI methods have also been demonstrated to provide functional imaging data on a variety of biological processes. In fact, MSI exceeds some of the classic functional imaging methods, demonstrating the ability to provide functional data from the nanoscale (subcellular) to whole tissue or organ level. This Perspective highlights several examples of how different MSI ionization and detection technologies can provide unprecedented detailed spatial maps of time-dependent biological processes, namely, nucleic acid synthesis, lipid metabolism, bioenergetics, and protein metabolism. By classifying various MSI methods under the umbrella of "functional MSI", we hope to draw attention to both the unique capabilities and accessibility with the aim of expanding this underappreciated field to include new approaches and applications.
Collapse
Affiliation(s)
- Allyson L Mellinger
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States.,Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Michael P Gamcsik
- UNC/NCSU Joint Department of Biomedical Engineering, Raleigh, North Carolina 27695, United States
| |
Collapse
|
36
|
Enders JR, Weed RA, Griffith EH, Muddiman DC. Development and validation of a high resolving power absolute quantitative per- and polyfluoroalkyl substances method incorporating Skyline data processing. Rapid Commun Mass Spectrom 2022; 36:e9295. [PMID: 35275435 PMCID: PMC9287086 DOI: 10.1002/rcm.9295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 03/09/2022] [Accepted: 03/09/2022] [Indexed: 06/14/2023]
Abstract
RATIONALE The ability to perform absolute quantitation and non-targeted analysis on a single mass spectrometry instrument would be advantageous to many researchers studying per- and polyfluoroalkyl substances (PFAS). High-resolution accurate mass (HRAM) instrumentation (typically deployed for non-targeted work) carries several advantages over traditional triple quadrupole workflows when performing absolute quantitation. Processing this data using a vendor-neutral software would promote collaboration for these environmental studies. METHODS LC-MS (Orbitrap Exploris 240) was used for absolute quantitation of 45 PFAS using precursor (MS1) peak areas for quantitation, whereas isotope pattern matching and fragmentation (MS2) pattern matching were used for qualitative identification. In addition, a fluorinated chromatographic column achieved superior separation compared to the typical C18 columns typically used in PFAS analyses. This method was validated across eight different chemical classes using recommended guidelines found in EPA Method 537.1 and Skyline data processing software. RESULTS The validated limits of all 45 compounds, as well as metrics or accuracy and reproducibility, are reported. Most compounds achieved limits of quantitation in the range of 2-50 ng/L. Four newly released Chemours-specific compounds (PEPA, PFO3OA, PFO4DA, and PFO5DoA) were also validated. Aspects of data analysis specific to high resolving power absolute quantitation are reviewed as are the details of processing these data via Skyline. CONCLUSIONS This method shows the feasibility of performing reproducible absolute quantitation of PFAS on an HRAM platform and does so using an open-source vendor-neutral data processing software to facilitate sharing of data across labs and institutions.
Collapse
Affiliation(s)
- Jeffrey R. Enders
- Molecular Education, Technology and Research Innovate Center (METRIC)North Carolina State UniversityRaleighNorth Carolina
- Department of Biological SciencesNorth Carolina State UniversityRaleighNorth Carolina
| | - Rebecca A. Weed
- Molecular Education, Technology and Research Innovate Center (METRIC)North Carolina State UniversityRaleighNorth Carolina
| | - Emily H. Griffith
- Department of Statistics, College of SciencesNorth Carolina State UniversityRaleighNorth Carolina
| | - David C. Muddiman
- Molecular Education, Technology and Research Innovate Center (METRIC)North Carolina State UniversityRaleighNorth Carolina
- Department of ChemistryNorth Carolina State UniversityRaleighNorth Carolina
| |
Collapse
|
37
|
Knizner KT, Bagley MC, Pu F, Elsen NL, Williams JD, Muddiman DC. Normalization techniques for high-throughput screening by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry. J Mass Spectrom 2022; 57:e4869. [PMID: 35678360 PMCID: PMC9287052 DOI: 10.1002/jms.4869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 05/21/2022] [Accepted: 05/26/2022] [Indexed: 05/29/2023]
Abstract
Mass spectrometry (MS) is an effective analytical tool for high-throughput screening (HTS) in the drug discovery field. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MS is a high-throughput platform that has achieved analysis times of sub-seconds-per-sample. Due to the high-throughput analysis speed, methods are needed to increase the analyte signal while decreasing the variability in IR-MALDESI-MS analyses to improve data quality and reduce false-positive hits. The Z-factor is used as a statistic of assay quality that can be improved by reducing the variation of target ion abundances or increasing signal. Herein we report optimal solvent compositions for increasing measured analyte abundances with direct analysis by IR-MALDESI-MS. We also evaluate normalization strategies, such as adding a normalization standard that is similar or dissimilar in structure to the model target drug, to reduce the variability of measured analyte abundances with direct analyses by IR-MALDESI-MS in both positive and negative ionization modes.
Collapse
Affiliation(s)
- Kevan T. Knizner
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Michael C. Bagley
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
| | - Fan Pu
- Drug Discovery Science and TechnologyAbbVie Inc.North ChicagoIllinoisUSA
| | - Nathaniel L. Elsen
- Drug Discovery Science and TechnologyAbbVie Inc.North ChicagoIllinoisUSA
| | - Jon D. Williams
- Drug Discovery Science and TechnologyAbbVie Inc.North ChicagoIllinoisUSA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of ChemistryNorth Carolina State UniversityRaleighNorth CarolinaUSA
- Molecular Education, Technology and Research Innovation Center (METRIC)North Carolina State UniversityRaleighNorth CarolinaUSA
| |
Collapse
|
38
|
Wilson L, Lee CA, Mason CF, Khodjaniyazova S, Flores KB, Muddiman DC, Sombers LA. Simultaneous Measurement of Striatal Dopamine and Hydrogen Peroxide Transients Associated with L-DOPA Induced Rotation in Hemiparkinsonian Rats. ACS Meas Sci Au 2022; 2:120-131. [PMID: 36785724 PMCID: PMC9838821 DOI: 10.1021/acsmeasuresciau.1c00030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Parkinson's disease (PD) is a neurodegenerative disorder commonly treated with levodopa (L-DOPA), which eventually induces abnormal involuntary movements (AIMs). The neurochemical contributors to these dyskinesias are unknown; however, several lines of evidence indicate an interplay of dopamine (DA) and oxidative stress. Here, DA and hydrogen peroxide (H2O2) were simultaneously monitored at discrete recording sites in the dorsal striata of hemiparkinsonian rats using fast-scan cyclic voltammetry. Mass spectrometry imaging validated the lesions. Hemiparkinsonian rats exhibited classic L-DOPA-induced AIMs and rotations as well as increased DA and H2O2 tone over saline controls after 1 week of treatment. By week 3, DA tone remained elevated beyond that of controls, but H2O2 tone was largely normalized. At this time point, rapid chemical transients were time-locked with spontaneous bouts of rotation. Striatal H2O2 rapidly increased with the initiation of contraversive rotational behaviors in lesioned L-DOPA animals, in both hemispheres. DA signals simultaneously decreased with rotation onset. The results support a role for these striatal neuromodulators in the adaptive changes that occur with L-DOPA treatment in PD and reveal a precise interplay between DA and H2O2 in the initiation of involuntary locomotion.
Collapse
Affiliation(s)
- Leslie
R. Wilson
- Department
of Chemistry, Department of Mathematics, Molecular Education, Technology,
and Research Innovation Center (METRIC), Center for Research in Scientific
Computation, and Comparative Medicine Institute, North Carolina
State University, Raleigh, North Carolina 27695, United States
| | - Christie A. Lee
- Department
of Chemistry, Department of Mathematics, Molecular Education, Technology,
and Research Innovation Center (METRIC), Center for Research in Scientific
Computation, and Comparative Medicine Institute, North Carolina
State University, Raleigh, North Carolina 27695, United States
| | - Catherine F. Mason
- Department
of Chemistry, Department of Mathematics, Molecular Education, Technology,
and Research Innovation Center (METRIC), Center for Research in Scientific
Computation, and Comparative Medicine Institute, North Carolina
State University, Raleigh, North Carolina 27695, United States
| | - Sitora Khodjaniyazova
- Department
of Chemistry, Department of Mathematics, Molecular Education, Technology,
and Research Innovation Center (METRIC), Center for Research in Scientific
Computation, and Comparative Medicine Institute, North Carolina
State University, Raleigh, North Carolina 27695, United States
| | - Kevin B. Flores
- Department
of Chemistry, Department of Mathematics, Molecular Education, Technology,
and Research Innovation Center (METRIC), Center for Research in Scientific
Computation, and Comparative Medicine Institute, North Carolina
State University, Raleigh, North Carolina 27695, United States
| | - David C. Muddiman
- Department
of Chemistry, Department of Mathematics, Molecular Education, Technology,
and Research Innovation Center (METRIC), Center for Research in Scientific
Computation, and Comparative Medicine Institute, North Carolina
State University, Raleigh, North Carolina 27695, United States
| | - Leslie A. Sombers
- Department
of Chemistry, Department of Mathematics, Molecular Education, Technology,
and Research Innovation Center (METRIC), Center for Research in Scientific
Computation, and Comparative Medicine Institute, North Carolina
State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
39
|
Abstract
Multimodal mass spectrometry imaging (MSI) is a critical technique used for deeply investigating biological systems by combining multiple MSI platforms in order to gain the maximum molecular information about a sample that would otherwise be limited by a single analytical technique. The aim of this work was to create a multimodal MSI approach that measures metabolomic and proteomic data from a single biological organ by combining infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) for metabolomic MSI and nanodroplet processing in one pot for trace samples (nanoPOTS) LC-MS/MS for spatially resolved proteome profiling. Adjacent tissue sections of rat brain were analyzed by each platform, and each data set was individually analyzed using previously optimized workflows. IR-MALDESI data sets were annotated by accurate mass and spectral accuracy using HMDB, METLIN, and LipidMaps databases, while nanoPOTS-LC-MS/MS data sets were searched against the rat proteome using the Sequest HT algorithm and filtered with a 1% FDR. The combined data revealed complementary molecular profiles distinguishing the corpus callosum against other sampled regions of the brain. A multiomic pathway integration showed a strong correlation between the two data sets when comparing average abundances of metabolites and corresponding enzymes in each brain region. This work demonstrates the first steps in the creation of a multimodal MSI technique that combines two highly sensitive and complementary imaging platforms. Raw data files are available in METASPACE (https://metaspace2020.eu/project/pace-2021) and MassIVE (identifier: MSV000088211).
Collapse
Affiliation(s)
- Crystal L. Pace
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA, 27606
| | - Jared Simmons
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA, 84602
| | - Ryan T. Kelly
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA, 84602
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA, 27606
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, USA, 27606
| |
Collapse
|
40
|
Knizner KT, Bagley MC, Garrard KP, Hauschild JP, Pu F, Elsen NL, Williams JD, Muddiman DC. Optimized C-Trap Timing of an Orbitrap 240 Mass Spectrometer for High-Throughput Screening and Native MS by IR-MALDESI. J Am Soc Mass Spectrom 2022; 33:328-334. [PMID: 35073091 PMCID: PMC9944060 DOI: 10.1021/jasms.1c00319] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Infrared matrix-assisted laser desorption ionization (IR-MALDESI) is a hybrid mass spectrometry ionization source that combines the benefits of electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) making it a great analytical tool for high-throughput screening (HTS) analyses. IR-MALDESI is coupled to an Orbitrap Exploris 240 mass spectrometer that utilizes a bent quadrupole (C-trap) to inject accumulated ions into the high-field Orbitrap mass analyzer. Here, we present a study on the optimized C-trap timing for HTS analyses by IR-MALDESI mass spectrometry. The timing between initial ion generation and the C-trap opening time was optimized to reduce unnecessary ambient ion accumulation in the mass spectrometer. The time in which the C-trap was held open, the ion accumulation time, was further optimized to maximize the accumulation of analyte ions generated using IR-MALDESI. The resulting C-trap opening scheme benefits small-molecule HTS analyses by IR-MALDESI by maximizing target ion abundances, minimizing ambient ion abundances, and minimizing the total analysis time per sample. The proposed C-trap timing scheme for HTS does not translate to large molecules; a NIST monoclonal antibody standard reference material was analyzed to demonstrate that larger analytes require longer ion accumulation times and that IR-MALDESI can measure intact antibodies in their native state.
Collapse
Affiliation(s)
- Kevan T. Knizner
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Michael C. Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | - Kenneth P. Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
- Precision Engineering Consortium, North Carolina State University, Raleigh, NC 27695, USA
| | | | - Fan Pu
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, USA
| | - Nathaniel L. Elsen
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, USA
| | - Jon D. Williams
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, USA
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
41
|
Pace CL, Angel PM, Drake RR, Muddiman DC. Mass Spectrometry Imaging of N-Linked Glycans in a Formalin-Fixed Paraffin-Embedded Human Prostate by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization. J Proteome Res 2022; 21:243-249. [PMID: 34860526 PMCID: PMC9944006 DOI: 10.1021/acs.jproteome.1c00822] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
N-Linked glycans are structurally diverse polysaccharides that represent significant biological relevance due to their involvement in disease progression and cancer. Due to their complex nature, N-linked glycans pose many analytical challenges requiring the continued development of analytical technologies. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a hybrid ionization technique commonly used for mass spectrometry imaging (MSI) applications. Previous work demonstrated IR-MALDESI to significantly preserve sialic acid containing N-linked glycans that otherwise require chemical derivatization prior to detection. Here, we demonstrate the first analysis of N-linked glycans in situ by IR-MALDESI MSI. A formalin-fixed paraffin-embedded human prostate tissue was analyzed in negative ionization mode after tissue washing, antigen retrieval, and pneumatic application of PNGase F for enzymatic digestion of N-linked glycans. Fifty-three N-linked glycans were confidently identified in the prostate sample where more than 60% contained sialic acid residues. This work demonstrates the first steps in N-linked glycan imaging of biological tissues by IR-MALDESI MSI. Raw data files are available in MassIVE (identifier: MSV000088414).
Collapse
Affiliation(s)
- Crystal L. Pace
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA, 27606
| | - Peggi M. Angel
- Department of Cell and Molecular Pharmacology and Experimental Therapeutics, Medical University of South Carolina, Charleston, SC, USA, 29425
| | - Richard R. Drake
- Department of Cell and Molecular Pharmacology and Experimental Therapeutics, Medical University of South Carolina, Charleston, SC, USA, 29425
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA, 27606,Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, USA 27695,Author for Correspondence: David C. Muddiman, Ph.D., FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Phone: 919-513-0084,
| |
Collapse
|
42
|
Enders JR, O’Neill GM, Whitten JL, Muddiman DC. Understanding the electrospray ionization response factors of per- and poly-fluoroalkyl substances (PFAS). Anal Bioanal Chem 2022; 414:1227-1234. [PMID: 34291300 PMCID: PMC8727445 DOI: 10.1007/s00216-021-03545-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 06/26/2021] [Accepted: 07/12/2021] [Indexed: 01/03/2023]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are used extensively in commercial products. Their unusual solubility properties make them an ideal class of compounds for various applications. However, these same properties have led to significant contamination and bioaccumulation given their persistence in the environment. Development of analytical techniques to detect and quantify these compounds must take into account the potential for these properties to perturb these measurements, specifically the potential to bias the electrospray ionization (ESI) process. Direct injection ESI analysis of 23 different PFAS species revealed that hydrophobicity and PFAS class can predict the ESI overall response factors. In this study, a method for predicting the behavior of individual PFAS compounds, including relative retention order in chromatography, is presented which is simply based on the number of fluorine atoms in the molecule as well as the class of the compound (e.g., perfluroalkylcarboxylic acids) vs. computational estimations (e.g., non-polar surface area and logP).
Collapse
Affiliation(s)
- Jeffrey R. Enders
- Molecular Education Technology and Research Innovate Center (METRIC), North Carolina State University, 2620 Yarbrough Drive, Raleigh, NC 27695, USA,Department of Biological Sciences, North Carolina State University, Raleigh, NC 27695, USA
| | - Grace M. O’Neill
- Department of Chemistry, North Carolina State University, 2620 Yarbrough Drive, Raleigh, NC 27695, USA
| | - Jerry L. Whitten
- Department of Chemistry, North Carolina State University, 2620 Yarbrough Drive, Raleigh, NC 27695, USA
| | - David C. Muddiman
- Molecular Education Technology and Research Innovate Center (METRIC), North Carolina State University, 2620 Yarbrough Drive, Raleigh, NC 27695, USA,Department of Chemistry, North Carolina State University, 2620 Yarbrough Drive, Raleigh, NC 27695, USA,Corresponding Author, , David C. Muddiman, Jacob and Betty Belin Distinguished Professor, Department of Chemistry, Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, 2620 Yarbrough Drive, Raleigh, North Carolina 27695, USA
| |
Collapse
|
43
|
Butler KE, Kalmar JG, Muddiman DC, Baker ES. Utilizing liquid chromatography, ion mobility spectrometry, and mass spectrometry to assess INLIGHT™ derivatized N-linked glycans in biological samples. Anal Bioanal Chem 2022; 414:623-637. [PMID: 34347113 PMCID: PMC8336533 DOI: 10.1007/s00216-021-03570-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Revised: 07/06/2021] [Accepted: 07/20/2021] [Indexed: 02/07/2023]
Abstract
Glycosylation is a ubiquitous co- and post-translational modification involved in the sorting, folding, and trafficking of proteins in biological systems; in humans, >50% of gene products are glycosylated with the cellular machinery of glycosylation compromising ~2% of the genome. Perturbations in glycosylation have been implicated in a variety of diseases including neurodegenerative diseases and certain types of cancer. However, understanding the relationship between a glycan and its biological role is often difficult due to the numerous glycan isomers that exist. To address this challenge, nanoflow liquid chromatography, ion mobility spectrometry, and mass spectrometry (nLC-IMS-MS) were combined with the Individuality Normalization when Labeling with the Isotopic Glycan Hydrazide Tags (INLIGHT™) strategy to study a series of glycan standards and those enzymatically released from the glycoproteins horseradish peroxidase, fetuin, and pooled human plasma. The combination of IMS and the natural (NAT) and stable-isotope label (SIL) in the INLIGHT™ strategy provided additional confidence for each glycan identification due to the mobility aligned NAT- and SIL-labeled glycans and further capabilities for isomer examinations. Additionally, molecular trend lines based on the IMS and MS dimensions were investigated for the INLIGHT™ derivatized glycans, facilitating rapid identification of putative glycans in complex biological samples.
Collapse
Affiliation(s)
- Karen E Butler
- Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Jaclyn Gowen Kalmar
- Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - David C Muddiman
- Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
- Center for Human Health and the Environment, North Carolina State University, Raleigh, NC, 27695, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, 27695, USA
| | - Erin S Baker
- Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA.
- Center for Human Health and the Environment, North Carolina State University, Raleigh, NC, 27695, USA.
- Comparative Medicine Institute, North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
44
|
Xi Y, Muddiman DC. Enhancing Metabolomic Coverage in Positive Ionization Mode Using Dicationic Reagents by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization. Metabolites 2021; 11:810. [PMID: 34940568 PMCID: PMC8708802 DOI: 10.3390/metabo11120810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 11/19/2021] [Accepted: 11/23/2021] [Indexed: 11/16/2022] Open
Abstract
Mass spectrometry imaging is a powerful tool to analyze a large number of metabolites with their spatial coordinates collected throughout the sample. However, the significant differences in ionization efficiency pose a big challenge to metabolomic mass spectrometry imaging. To solve the challenge and obtain a complete data profile, researchers typically perform experiments in both positive and negative ionization modes, which is time-consuming. In this work, we evaluated the use of the dicationic reagent, 1,5-pentanediyl-bis(1-butylpyrrolidinium) difluoride (abbreviated to [C5(bpyr)2]F2) to detect a broad range of metabolites in the positive ionization mode by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI MSI). [C5(bpyr)2]F2 at 10 µM was doped in 50% MeOH/H2O (v/v) electrospray solvent to form +1 charged adducted ions with anionic species (-1 charged) through post-electrospray ionization. This method was demonstrated with sectioned rat liver and hen ovary. A total of 73 deprotonated metabolites from rat liver tissue sections were successfully adducted with [C5(bpyr)2]2+ and putatively identified in the adducted positive ionization polarity, along with 164 positively charged metabolite ions commonly seen in positive ionization mode, which resulted in 44% increased molecular coverage. In addition, we were able to generate images of hen ovary sections showing their morphological features. Following-up tandem mass spectrometry (MS/MS) indicated that this dicationic reagent [C5(bpyr)2]2+ could form ionic bonds with the headgroup of glycerophospholipid ions. The addition of the dicationic reagent [C5(bpyr)2]2+ in the electrospray solvent provides a rapid and effective way to enhance the detection of metabolites in positive ionization mode.
Collapse
Affiliation(s)
- Ying Xi
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA;
| | - David C. Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA;
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|
45
|
Mellinger AL, Garrard KP, Khodjaniyazova S, Rabbani ZN, Gamcsik MP, Muddiman DC. Multiple Infusion Start Time Mass Spectrometry Imaging of Dynamic SIL-Glutathione Biosynthesis Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization. J Proteome Res 2021; 21:747-757. [PMID: 34807624 DOI: 10.1021/acs.jproteome.1c00636] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Due to the high association of glutathione metabolism perturbation with a variety of disease states, there is a dire need for analytical techniques to study glutathione kinetics. Additionally, the elucidation of microenvironmental effects on changes in glutathione metabolism would significantly improve our understanding of the role of glutathione in disease. We therefore present a study combining a multiple infusion start time protocol, stable isotope labeling technology, infrared matrix-assisted laser desorption electrospray ionization, and high-resolution accurate mass-mass spectrometry imaging to study spatial changes in glutathione kinetics across in sectioned mouse liver tissues. After injecting a mouse with the isotopologues [2-13C,15N]-glycine, [1,2-13C2]-glycine, and [1,2-13C2,15N]-glycine at three different time points, we were able to fully resolve and spatially map their metabolism into three isotopologues of glutathione and calculate their isotopic enrichment in glutathione. We created a tool in the open-source mass spectrometry imaging software MSiReader to accurately compute the percent isotope enrichment (PIE) of these labels in glutathione and visualize them in heat-maps of the tissue sections. In areas of high flux, we found that each label enriched an approximate median of 1.6%, 1.8%, and 1.5%, respectively, of the glutathione product pool measured in each voxel. This method may be adapted to study the heterogeneity of glutathione flux in diseased versus healthy tissues.
Collapse
Affiliation(s)
- Allyson L Mellinger
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States.,Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Sitora Khodjaniyazova
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Zahid N Rabbani
- UNC/NCSU Joint Department of Biomedical Engineering, Raleigh, North Carolina 27695, United States
| | - Michael P Gamcsik
- UNC/NCSU Joint Department of Biomedical Engineering, Raleigh, North Carolina 27695, United States
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States.,Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
46
|
Lin CY, Sun Y, Song J, Chen HC, Shi R, Yang C, Liu J, Tunlaya-Anukit S, Liu B, Loziuk PL, Williams CM, Muddiman DC, Lin YCJ, Sederoff RR, Wang JP, Chiang VL. Enzyme Complexes of Ptr4CL and PtrHCT Modulate Co-enzyme A Ligation of Hydroxycinnamic Acids for Monolignol Biosynthesis in Populus trichocarpa. Front Plant Sci 2021; 12:727932. [PMID: 34691108 PMCID: PMC8527181 DOI: 10.3389/fpls.2021.727932] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Accepted: 09/13/2021] [Indexed: 06/13/2023]
Abstract
Co-enzyme A (CoA) ligation of hydroxycinnamic acids by 4-coumaric acid:CoA ligase (4CL) is a critical step in the biosynthesis of monolignols. Perturbation of 4CL activity significantly impacts the lignin content of diverse plant species. In Populus trichocarpa, two well-studied xylem-specific Ptr4CLs (Ptr4CL3 and Ptr4CL5) catalyze the CoA ligation of 4-coumaric acid to 4-coumaroyl-CoA and caffeic acid to caffeoyl-CoA. Subsequently, two 4-hydroxycinnamoyl-CoA:shikimic acid hydroxycinnamoyl transferases (PtrHCT1 and PtrHCT6) mediate the conversion of 4-coumaroyl-CoA to caffeoyl-CoA. Here, we show that the CoA ligation of 4-coumaric and caffeic acids is modulated by Ptr4CL/PtrHCT protein complexes. Downregulation of PtrHCTs reduced Ptr4CL activities in the stem-differentiating xylem (SDX) of transgenic P. trichocarpa. The Ptr4CL/PtrHCT interactions were then validated in vivo using biomolecular fluorescence complementation (BiFC) and protein pull-down assays in P. trichocarpa SDX extracts. Enzyme activity assays using recombinant proteins of Ptr4CL and PtrHCT showed elevated CoA ligation activity for Ptr4CL when supplemented with PtrHCT. Numerical analyses based on an evolutionary computation of the CoA ligation activity estimated the stoichiometry of the protein complex to consist of one Ptr4CL and two PtrHCTs, which was experimentally confirmed by chemical cross-linking using SDX plant protein extracts and recombinant proteins. Based on these results, we propose that Ptr4CL/PtrHCT complexes modulate the metabolic flux of CoA ligation for monolignol biosynthesis during wood formation in P. trichocarpa.
Collapse
Affiliation(s)
- Chien-Yuan Lin
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
- Joint BioEnergy Institute, Lawrence Berkeley National Laboratory, Berkeley, CA, United States
| | - Yi Sun
- State Key Laboratory of Tree Genetics and Breeding, Northeast Forestry University, Harbin, China
| | - Jina Song
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, United States
| | - Hsi-Chuan Chen
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
| | - Rui Shi
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
| | - Chenmin Yang
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
| | - Jie Liu
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
| | - Sermsawat Tunlaya-Anukit
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
| | - Baoguang Liu
- State Key Laboratory of Tree Genetics and Breeding, Northeast Forestry University, Harbin, China
- Department of Forestry, Beihua University, Jilin, China
| | - Philip L. Loziuk
- W.M. Keck FTMS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC, United States
| | - Cranos M. Williams
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, United States
| | - David C. Muddiman
- W.M. Keck FTMS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC, United States
| | - Ying-Chung Jimmy Lin
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
- State Key Laboratory of Tree Genetics and Breeding, Northeast Forestry University, Harbin, China
| | - Ronald R. Sederoff
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
| | - Jack P. Wang
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
- State Key Laboratory of Tree Genetics and Breeding, Northeast Forestry University, Harbin, China
| | - Vincent L. Chiang
- Forest Biotechnology Group, Department of Forestry and Environmental Resources, North Carolina State University, Raleigh, NC, United States
- State Key Laboratory of Tree Genetics and Breeding, Northeast Forestry University, Harbin, China
| |
Collapse
|
47
|
Bagley MC, Muddiman DC. Investigations of β-carotene radical cation formation in infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI). Rapid Commun Mass Spectrom 2021; 35:e9133. [PMID: 34038981 DOI: 10.1002/rcm.9133] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 05/15/2021] [Accepted: 05/24/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE Radical cationization of endogenous hydrocarbons in cherry tomatoes was previously reported using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI), a mass spectrometry imaging technique that operates at ambient conditions and requires no sample derivatization. Due to the surprising nature of this odd-electron ionization, subsequent experiments were performed on β-carotene to determine the amount of radical cationization across different sampling conditions. METHODS β-Carotene was analyzed across a variety of sample states using IR-MALDESI followed by Orbitrap mass spectrometric analysis: first, as a standard in ethanol in a well plate; second, as particulates on printer paper; and third, as particulates covered by an ice matrix. These techniques were also performed with a β-carotene standard either in solution with a reducing agent (ascorbic acid) or with ascorbic acid in the electrospray solution. RESULTS Tandem mass spectrometry confirmed the presence of the radical cation of β-carotene by comparing fragments against NIST and METLIN databases. It was always analyzed as a radical cation when sampled from solution, where ascorbic acid increased radical cation abundance when in solution with β-carotene. Mixed-mode ionization between radical cationization and proton adduction was observed from dried particulates using IR-MALDESI. CONCLUSIONS There are several potential mechanisms for β-carotene radical cationization prior to IR-MALDESI analysis, with multiphoton ionization, thermal degradation, and/or reaction with oxygen appearing to be the most logical explanations. Furthermore, although not the primary cause, changing certain aspects of sample conditions can result in significant mixed-mode ionization with competing protonation.
Collapse
Affiliation(s)
- M Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, NC, 27695, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, 27695, USA
| |
Collapse
|
48
|
Tu A, Said N, Muddiman DC. Spatially resolved metabolomic characterization of muscle invasive bladder cancer by mass spectrometry imaging. Metabolomics 2021; 17:70. [PMID: 34287708 PMCID: PMC8893274 DOI: 10.1007/s11306-021-01819-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 07/09/2021] [Indexed: 12/25/2022]
Abstract
INTRODUCTION Muscle invasive bladder cancer (MIBC) is an advanced stage of bladder cancer which poses a severe threat to life. Cancer development is usually accompanied by remarkable alterations in cell metabolism, and hence deep insights into MIBC at the metabolomic level can facilitate the understanding of the biochemical mechanisms involved in the cancer development and progression. METHODS In this proof-of-concept study, the optimal cutting temperature (OCT)-embedded MIBC samples were first washed with pure water to remove the polymer compounds which could cause severe signal suppression during mass spectrometry. Further, the tissue sections were analyzed by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI MSI), providing an overview on the spatially resolved metabolomic profiles. RESULTS The MSI data enabled the discrimination between not only the cancerous and normal tissues, but also the subregions within a tissue section associated with different disease states. Using t-Distributed Stochastic Neighbor Embedding (t-SNE), the hyperdimensional MSI data was mapped into a two-dimensional space to visualize the spectral similarity, providing evidence that metabolomic alterations might have occurred outside the histopathological tumor border. Least absolute shrinkage and selection operator (LASSO) was further employed to classify sample pathology in a pixel-wise manner, yielding excellent prediction sensitivity and specificity up to 96% based on the statistically characteristic spectral features. CONCLUSION The results demonstrate great promise of IR-MALDESI MSI to identify molecular changes derived from cancer and unveil tumor heterogeneity, which can potentially promote the discovery of clinically relevant biomarkers and allow for applications in precision medicine.
Collapse
Affiliation(s)
- Anqi Tu
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Neveen Said
- Departments of Cancer Biology, Pathology, and Urology, Wake Forest University School of Medicine, Wake Forest Baptist Comprehensive Cancer Center, Winston Salem, NC, 27157, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA.
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, 27695, USA.
| |
Collapse
|
49
|
Tu A, Garrard KP, Said N, Muddiman DC. In situ detection of fatty acid C=C positional isomers by coupling on-tissue mCPBA epoxidation with infrared matrix-assisted laser desorption electrospray ionization mass spectrometry. Rapid Commun Mass Spectrom 2021; 35:e9119. [PMID: 33942403 PMCID: PMC8988907 DOI: 10.1002/rcm.9119] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Revised: 04/28/2021] [Accepted: 04/28/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE Unsaturated fatty acids (UFAs) play vital roles in regulating cellular functions. In-depth structural characterization of UFAs such as localizing carbon-carbon double bonds is fundamentally important but poses considerable challenges in mass spectrometry (MS) given that the most widely accessible ion activation method, low-energy collision-induced dissociation (CID), primarily generates uninformative fragments (e.g., neutral loss of CO2 ) that are not suggestive of the double-bond positions. METHODS m-Chloroperoxybenzoic acid (mCPBA) was uniformly deposited onto the sample slides using a TM Sprayer, converting the carbon-carbon double bonds into epoxides under ambient conditions. The epoxidation product was ionized in situ by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry (IR-MALDESI-MS), and subsequently cleaved via CID, generating a diagnostic ion pair associated with the double-bond position. The reaction efficiency, sensitivity and relative quantification capability of the method were validated with five UFA standards dried on glass slides, and then this strategy was demonstrated on thin tissue sections of rat liver and human bladder. RESULTS The mCPBA reaction yielded conversion rates in the range of 44-60% in 10 min with high specificity and sensitivity. Further tandem mass spectrometry (MS/MS) of the mono-epoxidized products generated informative fragment ions specific to the double-bond positions, and relative quantification of positional isomers in binary mixtures was performed across a wide mole fraction from 0 to 1. An innovative spiral scan pattern was utilized during data acquisition, elucidating the major isomeric compositions of multiple UFAs from a tissue section in a single run. CONCLUSIONS The on-tissue mCPBA epoxidation was implemented into an ambient MS imaging workflow to offer a rapid and simple way for in situ identification and relative quantification of double-bond positional isomers without the requirement for instrument modification. The method can be readily implemented on many other MS platforms to reveal the role of double-bond positional isomers in lipid biology and to discover potential biomarkers.
Collapse
Affiliation(s)
- Anqi Tu
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
| | - Kenneth P Garrard
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
- Precision Engineering Consortium, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, 27695, USA
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, 27695, USA
| | - Neveen Said
- Departments of Cancer Biology, Pathology, and Urology, Wake Forest University School of Medicine, Wake Forest Baptist Comprehensive Cancer Center, Winston Salem, NC, 27157, USA
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
- Molecular Education, Technology and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, 27695, USA
| |
Collapse
|
50
|
Bagley MC, Pace CL, Ekelöf M, Muddiman DC. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging analysis of endogenous metabolites in cherry tomatoes. Analyst 2021; 145:5516-5523. [PMID: 32602477 DOI: 10.1039/d0an00818d] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
We report the spatially resolved metabolic profiling of cherry tomatoes using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI), a mass spectrometry imaging (MSI) technique that operates at ambient conditions and requires no sample derivatization. Tomatoes were flash frozen, cryosectioned and imaged with adequate spatial resolution to distinguish between the major tissue structures of a tomato including the skin, mesocarp, endocarp, locular tissue, septum, placenta, seed and seed coating. Metabolites were imaged from 100-1200 m/z, enabling significant coverage of a diverse array of metabolites including amino acids and lipids along with the major secondary metabolite classes: terpenes, phenolics, glycosides, and alkaloids. During the metabolic profiling, we found endogenous carotenoid hydrocarbons, namely lycopene or its structural isomer β-carotene, ionized as radical cations. To our knowledge, this is the first demonstration of ionizing hydrocarbons in the MSI field.
Collapse
Affiliation(s)
- M Caleb Bagley
- FTMS Laboratory for Human Health Research, Department of Chemistry, USA.
| | - Crystal L Pace
- FTMS Laboratory for Human Health Research, Department of Chemistry, USA.
| | - Måns Ekelöf
- FTMS Laboratory for Human Health Research, Department of Chemistry, USA.
| | - David C Muddiman
- FTMS Laboratory for Human Health Research, Department of Chemistry, USA. and Department of Plant and Microbial Biology, USA and Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC 27695, USA
| |
Collapse
|