Veeram Reddy SR, Arar Y, Zahr RA, Gooty V, Hernandez J, Potersnak A, Douglas P, Blair Z, Greer JS, Roujol S, Forte MNV, Greil G, Nugent AW, Hussain T. Invasive cardiovascular magnetic resonance (iCMR) for diagnostic right and left heart catheterization using an MR-conditional guidewire and passive visualization in congenital heart disease. J Cardiovasc Magn Reson 2020; 22:20. [PMID: 32213193 PMCID: PMC7098096 DOI: 10.1186/s12968-020-0605-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Accepted: 02/05/2020] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Today's standard of care, in the congenital heart disease (CHD) population, involves performing cardiac catheterization under x-ray fluoroscopy and cardiac magnetic resonance (CMR) imaging separately. The unique ability of CMR to provide real-time functional imaging in multiple views without ionizing radiation exposure has the potential to be a powerful tool for diagnostic and interventional procedures. Limiting fluoroscopic radiation exposure remains a challenge for pediatric interventional cardiologists. This pilot study's objective is to establish feasibility of right (RHC) and left heart catheterization (LHC) during invasive CMR (iCMR) procedures at our institution in the CHD population. Furthermore, we aim to improve simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures. METHODS Subjects with CHD were enrolled in a pilot study for iCMR procedures at 1.5 T with an MR-conditional guidewire. The CMR area is located adjacent to a standard catheterization laboratory. Using the interactive scanning mode for real-time control of the imaging location, a dilute gadolinium-filled balloon-tip catheter was used in combination with an MR-conditional guidewire to obtain cardiac saturations and hemodynamics. A recently developed catheter tracking technique using a real-time single-shot balanced steady-state free precession (bSSFP), flip angle (FA) 35-45°, echo time (TE) 1.3 ms, repetition time (TR) 2.7 ms, 40° partial saturation (pSAT) pre-pulse was used to visualize the gadolinium-filled balloon, MR-conditional guidewire, and cardiac structures simultaneously. MR-conditional guidewire visualization was enabled due to susceptibility artifact created by distal markers. Pre-clinical phantom testing was performed to determine the optimum imaging FA-pSAT combination. RESULTS The iCMR procedure was successfully performed to completion in 31/34 (91%) subjects between August 1st, 2017 to December 13th, 2018. Median age and weight were 7.7 years and 25.2 kg (range: 3 months - 33 years and 8 - 80 kg). Twenty-one subjects had single ventricle (SV) anatomy: one subject was referred for pre-Glenn evaluation, 11 were pre-Fontan evaluations and 9 post-Fontan evaluations for protein losing enteropathy (PLE) and/or cyanosis. Thirteen subjects had bi-ventricular (BiV) anatomy, 4 were referred for coarctation of the aorta (CoA) evaluations, 3 underwent vaso-reactivity testing with inhaled nitric oxide, 3 investigated RV volume dimensions, two underwent branch PA stenosis evaluation, and the remaining subject was status post heart transplant. No catheter related complications were encountered. Average time taken for first pass RHC, LHC/aortic pull back, and to cross the Fontan fenestration was 5.2, 3.0, and 6.5 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 331/337 (98%). Subjects were transferred to the x-ray fluoroscopy lab if further intervention was required including Fontan fenestration device closure, balloon angioplasty of pulmonary arteries/conduits, CoA stenting, and/or coiling of aortopulmonary (AP) collaterals. Starting with subject #10, an MR-conditional guidewire was used in all subsequent subjects (15 SV and 10 BiV) with a success rate of 96% (24/25). Real-time CMR-guided RHC (25/25 subjects, 100%), retrograde and prograde LHC/aortic pull back (24/25 subjects, 96%), CoA crossing (3/4 subjects, 75%) and Fontan fenestration test occlusion (2/3 subjects, 67%) were successfully performed in the majority of subjects when an MR-conditional guidewire was utilized. CONCLUSION Feasibility for detailed diagnostic RHC, LHC, and Fontan fenestration test occlusion iCMR procedures in SV and BiV pediatric subjects with complex CHD is demonstrated with the aid of an MR-conditional guidewire. A novel real-time pSAT GRE sequence with optimized FA-pSAT angle has facilitated simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures.
Collapse
Affiliation(s)
- Surendranath R. Veeram Reddy
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
- Pediatric Cardiology, Children’s Medical Center Dallas, 1935 Medical District Dr, Dallas, TX 75235 USA
| | - Yousef Arar
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
- Pediatric Cardiology, Children’s Medical Center Dallas, 1935 Medical District Dr, Dallas, TX 75235 USA
| | - Riad Abou Zahr
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
- Pediatric Cardiology, Children’s Medical Center Dallas, 1935 Medical District Dr, Dallas, TX 75235 USA
| | - Vasu Gooty
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
- Pediatric Cardiology, Children’s Medical Center Dallas, 1935 Medical District Dr, Dallas, TX 75235 USA
| | - Jennifer Hernandez
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
- Pediatric Cardiology, Children’s Medical Center Dallas, 1935 Medical District Dr, Dallas, TX 75235 USA
| | - Amanda Potersnak
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
| | - Phillip Douglas
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
| | - Zachary Blair
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
| | - Joshua S. Greer
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
| | - Sébastien Roujol
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
| | - Mari Nieves Velasco Forte
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
| | - Gerald Greil
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
- Pediatric Cardiology, Children’s Medical Center Dallas, 1935 Medical District Dr, Dallas, TX 75235 USA
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
| | - Alan W. Nugent
- Ann & Robert H. Lurie Children’s Hospital of Chicago, 225 E Chicago Ave, Chicago, IL 60611 USA
| | - Tarique Hussain
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
- Pediatric Cardiology, Children’s Medical Center Dallas, 1935 Medical District Dr, Dallas, TX 75235 USA
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390 USA
| |
Collapse
|
2
|
Schleicher KE, Bock M, Düring K, Kroboth S, Krafft AJ. Radial MRI with variable echo times: reducing the orientation dependency of susceptibility artifacts of an MR-safe guidewire. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017; 31:235-242. [PMID: 28770356 DOI: 10.1007/s10334-017-0645-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 07/20/2017] [Accepted: 07/21/2017] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Guidewires are indispensable tools for intravascular MR-guided interventions. Recently, an MR-safe guidewire made from a glass-fiber/epoxy compound material with embedded iron particles was developed. The size of the induced susceptibility artifact, and thus the guidewire's visibility, depends on its orientation against B 0. We present a radial acquisition scheme with variable echo times that aims to reduce the artifact's orientation dependency. MATERIALS AND METHODS The radial acquisition scheme uses sine-squared modulated echo times depending on the physical direction of the spoke to balance the susceptibility artifact of the guidewire. The acquisition scheme was studied in simulations based on dipole fields and in phantom experiments for different orientations of the guidewire against B 0. The simulated and measured artifact widths were quantitatively compared. RESULTS Compared to acquisitions with non-variable echo times, the proposed acquisition scheme shows a reduced angular variability. For the two main orientations (i.e., parallel and perpendicular to B 0), the ratio of the artifact widths was reduced from about 2.2 (perpendicular vs. parallel) to about 1.2 with the variable echo time approach. CONCLUSION The reduction of the orientation dependency of the guidewire's artifact via sine-squared varying echo times could be verified in simulations and measurements. The more balanced artifact allows for a better overall visibility of the guidewire.
Collapse
Affiliation(s)
- Katharina E Schleicher
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Strasse 60a, 79106, Freiburg, Germany.
| | - Michael Bock
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Strasse 60a, 79106, Freiburg, Germany
| | | | - Stefan Kroboth
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Strasse 60a, 79106, Freiburg, Germany
| | - Axel J Krafft
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Strasse 60a, 79106, Freiburg, Germany
| |
Collapse
|
3
|
Massmann A, Buecker A, Schneider GK. Glass-Fiber-based MR-safe Guidewire for MR Imaging-guided Endovascular Interventions: In Vitro and Preclinical in Vivo Feasibility Study. Radiology 2017; 284:541-551. [PMID: 28301310 DOI: 10.1148/radiol.2017152742] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Purpose To evaluate glass-fiber-based guidewires that are safe for magnetic resonance (MR) imaging-guided endovascular interventions by using a phantom and an in vivo swine model. Materials and Methods MR imaging-safe guidewires were made from micropultruded glass and/or aramid fibers and epoxy resin with diameters of 0.89 mm (0.035 inch) for standard and stiff guidewires and 0.36 mm (0.014 inch) for micro guidewires. MR imaging visibility and mechanical properties were assessed in a pulsatile flow model. After approval was obtained from the institutional animal care and use committee, MR imaging guidewires were evaluated for standard endovascular procedures in nine pigs. Real-time steady-state free-precession sequences were used for MR imaging-guided catheterization, balloon dilation, and stent implantation into aorto-iliac/visceral arteries and the vena cava (temporal resolution, five images per second; and spatial resolution, 150-mm field of view, and 128 × 128 matrix) with a 1.5-T clinical imager. Visualization with the guidewires was rated on a four-point scale, handling was rated on a three-point scale, and catheterization times for different vessel regions were determined by two interventional radiologists. Afterward, handling ratings and catheterization times were obtained for standard nitinol guidewires during x-ray-based fluoroscopy. Cannulation times, signal intensity in each vessel region, and visualization and handling ratings were measured for the MR imaging guidewires. Bland-Altman analysis was performed for inter- and intraobserver variability of cannulation time. Spearman rank correlation was used to compare handling of MR imaging guidewires and standard nitinol guidewires. Results MR imaging guidewires were characterized by good to excellent visibility, with a continuous artifact of 2 mm in diameter and 4 × 8-mm ball-shaped tip marker. Stiffness, flexibility, and guidance reflected comparable times for all in vitro and in vivo procedures with both the MR imaging and standard nitinol guidewires. Standard and micro MR imaging guidewires were most suitable for the iliac crossover maneuver. Phantom visceral artery cannulation was easier with standard and micro MR imaging guidewires. The stiff MR imaging guidewire provided the best support for cannulation of the swine aorta and vena cava. All interventional procedures were performed successfully without complications. Conclusion Preliminary results showed that the use of glass-fiber-based guidewires for evaluation of MR imaging-guided endovascular interventions is technically feasible and safe in a swine model, and potentially, in humans. © RSNA, 2017 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Alexander Massmann
- From the Clinic for Diagnostic and Interventional Radiology, Saarland University Medical Center, Kirrberger Strasse, Geb. 50.1, 66421 Homburg/Saar, Germany
| | - Arno Buecker
- From the Clinic for Diagnostic and Interventional Radiology, Saarland University Medical Center, Kirrberger Strasse, Geb. 50.1, 66421 Homburg/Saar, Germany
| | - Guenther K Schneider
- From the Clinic for Diagnostic and Interventional Radiology, Saarland University Medical Center, Kirrberger Strasse, Geb. 50.1, 66421 Homburg/Saar, Germany
| |
Collapse
|
4
|
Basar B, Rogers T, Ratnayaka K, Campbell-Washburn AE, Mazal JR, Schenke WH, Sonmez M, Faranesh AZ, Lederman RJ, Kocaturk O. Segmented nitinol guidewires with stiffness-matched connectors for cardiovascular magnetic resonance catheterization: preserved mechanical performance and freedom from heating. J Cardiovasc Magn Reson 2015; 17:105. [PMID: 26620420 PMCID: PMC4665398 DOI: 10.1186/s12968-015-0210-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Accepted: 11/19/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Conventional guidewires are not suitable for use during cardiovascular magnetic resonance (CMR) catheterization. They employ metallic shafts for mechanical performance, but which are conductors subject to radiofrequency (RF) induced heating. To date, non-metallic CMR guidewire designs have provided inadequate mechanical support, trackability, and torquability. We propose a metallic guidewire for CMR that is by design intrinsically safe and that retains mechanical performance of commercial guidewires. METHODS The NHLBI passive guidewire is a 0.035" CMR-safe, segmented-core nitinol device constructed using short nitinol rod segments. The electrical length of each segment is less than one-quarter wavelength at 1.5 Tesla, which eliminates standing wave formation, and which therefore eliminates RF heating along the shaft. Each of the electrically insulated segments is connected with nitinol tubes for stiffness matching to assure uniform flexion. Iron oxide markers on the distal shaft impart conspicuity. Mechanical integrity was tested according to International Organization for Standardization (ISO) standards. CMR RF heating safety was tested in vitro in a phantom according to American Society for Testing and Materials (ASTM) F-2182 standard, and in vivo in seven swine. Results were compared with a high-performance commercial nitinol guidewire. RESULTS The NHLBI passive guidewire exhibited similar mechanical behavior to the commercial comparator. RF heating was reduced from 13 °C in the commercial guidewire to 1.2 °C in the NHLBI passive guidewire in vitro, using a flip angle of 75°. The maximum temperature increase was 1.1 ± 0.3 °C in vivo, using a flip angle of 45°. The guidewire was conspicuous during left heart catheterization in swine. CONCLUSIONS We describe a simple and intrinsically safe design of a metallic guidewire for CMR cardiovascular catheterization. The guidewire exhibits negligible heating at high flip angles in conformance with regulatory guidelines, yet mechanically resembles a high-performance commercial guidewire. Iron oxide markers along the length of the guidewire impart passive visibility during real-time CMR. Clinical translation is imminent.
Collapse
Affiliation(s)
- Burcu Basar
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey.
| | - Toby Rogers
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
| | - Kanishka Ratnayaka
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
- Department of Cardiology, Children's National Medical Center, Washington DC, USA.
| | - Adrienne E Campbell-Washburn
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
| | - Jonathan R Mazal
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
| | - William H Schenke
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
| | - Merdim Sonmez
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
| | - Anthony Z Faranesh
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
| | - Robert J Lederman
- National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey.
| |
Collapse
|
5
|
Rube MA, Fernandez-Gutierrez F, Cox BF, Holbrook AB, Houston JG, White RD, McLeod H, Fatahi M, Melzer A. Preclinical feasibility of a technology framework for MRI-guided iliac angioplasty. Int J Comput Assist Radiol Surg 2014; 10:637-50. [PMID: 25102933 DOI: 10.1007/s11548-014-1102-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2014] [Accepted: 07/02/2014] [Indexed: 11/25/2022]
Abstract
PURPOSE Interventional MRI has significant potential for image guidance of iliac angioplasty and related vascular procedures. A technology framework with in-room image display, control, communication and MRI-guided intervention techniques was designed and tested for its potential to provide safe, fast and efficient MRI-guided angioplasty of the iliac arteries. METHODS A 1.5-T MRI scanner was adapted for interactive imaging during endovascular procedures using new or modified interventional devices such as guidewires and catheters. A perfused vascular phantom was used for testing. Pre-, intra- and post-procedural visualization and measurement of vascular morphology and flow was implemented. A detailed analysis of X-ray fluoroscopic angiography workflow was conducted and applied. Two interventional radiologists and one physician in training performed 39 procedures. All procedures were timed and analyzed. RESULTS MRI-guided iliac angioplasty procedures were successfully performed with progressive adaptation of techniques and workflow. The workflow, setup and protocol enabled a reduction in table time for a dedicated MRI-guided procedure to 6 min 33 s with a mean procedure time of 9 min 2 s, comparable to the mean procedure time of 8 min 42 s for the standard X-ray-guided procedure. CONCLUSIONS MRI-guided iliac vascular interventions were found to be feasible and practical using this framework and optimized workflow. In particular, the real-time flow analysis was found to be helpful for pre- and post-interventional assessments. Design optimization of the catheters and in vivo experiments are required before clinical evaluation.