Ito H, Matsubara K, Kobayashi I, Shimakawa Y, Murayama D, Sakai T, Isobe T, Yanagawa N, Ochi S. Relationship between assistant's lens exposure and dose information during computed tomography examinations. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2024; 44:021513. [PMID: 38722292 DOI: 10.1088/1361-6498/ad4903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Accepted: 05/09/2024] [Indexed: 05/18/2024]
Abstract
According to International Commission of Radiological Protection, the equivalent dose limit for the eye lens for occupational exposure is recommended to be 20 mSv yr-1, averaged over 5 years, with no single year above 50 mSv. Some studies reported the measurement of assistant's lens exposure in diagnostic computed tomography (CT) examinations, but further investigation is still required in the association between the lens dose for assistants and various dose parameters. Therefore, we measured the assistant's lens exposure using small optically stimulated luminescence dosimeters. The type of occupation, type of assistance, total scan time, total mAs, total scan length, and dose-length product (DLP) were recorded and analyzed in association with air kerma at the lens position. The assistance was classified into four types: 'assisted ventilation,' 'head holding,' 'body holding,' and 'raising patient's arm.' The air kerma of lens position was not significantly different for each assistance type (p< 0.05, Kruskal-Wallis test). Further, the lens doses for assistants correlated with DLP, but with various strengths of correlation with the assistance type and were influenced by the distance from the CT gantry. In conclusion, lens dose during assistance and DLP demonstrated the strongest correlation. 'Raising patient's arm' and 'head holding' exhibited stronger correlations, which required less table movement during the CT scan than 'assisted ventilation' and 'body holding'.
Collapse
Affiliation(s)
- Hajime Ito
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2, Okayamadai, Togane, Chiba 283-8686, Japan
- Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan
| | - Kosuke Matsubara
- Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan
| | - Ikuo Kobayashi
- Research Institute of Nuclear Engineering, University of Fukui, 1-3-33 Kanawa, Tsuruga, Fukui 914-0055, Japan
| | - Yurie Shimakawa
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2, Okayamadai, Togane, Chiba 283-8686, Japan
| | - Daichi Murayama
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2, Okayamadai, Togane, Chiba 283-8686, Japan
| | - Takayuki Sakai
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2, Okayamadai, Togane, Chiba 283-8686, Japan
| | - Tomonori Isobe
- Institute of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan
| | - Noriyuki Yanagawa
- Department of Radiological Technology, Faculty of Health Sciences, Tsukuba International University, 6-20-1, Manabe, Tsuchiura, Ibaraki 300-0051, Japan
| | - Shigehiro Ochi
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2, Okayamadai, Togane, Chiba 283-8686, Japan
| |
Collapse
|
2
|
Fukushima K, Matsubara K, Tanabe M, Ito H. Eye lens dose for medical staff assisting patients during computed tomography: comparison of several types of radioprotective glasses. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2023; 43:021505. [PMID: 37023744 DOI: 10.1088/1361-6498/accaf1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 04/06/2023] [Indexed: 06/19/2023]
Abstract
Medical staff sometimes assists patients in the examination room during computed tomography (CT) scans for several purposes. This study aimed to investigate the dose reduction effects of four radioprotective glasses with different lead equivalents and lens shapes. A medical staff phantom was positioned assuming body movement restraint of the patient during chest CT, and Hp(3) at the eye surfaces of the medical staff phantom and inside the lens of the four types of radioprotective glasses were measured by changing the distance of the staff phantom from the gantry, eye height, and width of the nose pad. The Hp(3) at the right eye surface with glasses of 0.50-0.75 mmPb and 0.07 mmPb was approximately 83.5% and 58.0%, respectively, lower than that without radioprotective glasses. The dose reduction rates at left eye surface increased with over-glass type glasses by 14%-28% by increasing the distance from the CT gantry to the staff phantom from 25 to 65 cm. The dose reduction rates at the left eye surface decreased with over-glass type glasses by 26%-31% by increasing the height of the eye lens for the medical staff phantom from 130 to 170 cm. The Hp(3) on the left eye surface decreased by 46.9% with the widest nose pad width compared to the narrowest nose pad width for the glasses with adjustable nose pad width. The radioprotective glasses for staff assisting patients during CT examinations should have a high lead equivalent and no gap around the nose and under the front lens.
Collapse
Affiliation(s)
- Kotaro Fukushima
- Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, Japan
| | - Kosuke Matsubara
- Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, Japan
| | - Mariko Tanabe
- Department of Radiological Technology, School of Health Sciences, College of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, Japan
| | - Hajime Ito
- Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, Japan
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2 Okayamadai, Togane, Chiba, Japan
| |
Collapse
|
3
|
Miyaji N, Miwa K, Iimori T. [Eye Lens Monitoring for Nuclear Medicine]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:1367-1375. [PMID: 36403970 DOI: 10.6009/jjrt.2022-2110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Affiliation(s)
- Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
| | | |
Collapse
|
4
|
Miyaji N, Miwa K, Iimori T, Wagatsuma K, Tsushima H, Yokotsuka N, Murata T, Kasahara T, Terauchi T. Determination of a reliable assessment for occupational eye lens dose in nuclear medicine. J Appl Clin Med Phys 2022; 23:e13713. [PMID: 35775691 PMCID: PMC9359038 DOI: 10.1002/acm2.13713] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 05/31/2022] [Accepted: 06/14/2022] [Indexed: 11/29/2022] Open
Abstract
The most recent statement published by the International Commission on Radiological Protection describes a reduction in the maximum allowable occupational eye lens dose from 150 to 20 mSv/year (averaged over 5‐year periods). Exposing the eye lens to radiation is a concern for nuclear medicine staff who handle radionuclide tracers with various levels of photon energy. This study aimed to define the optimal dosimeter and means of measuring the amount of exposure to which the eye lens is exposed during a routine nuclear medicine practice. A RANDO human phantom attached to Glass Badge and Luminess Badge for body or neck, DOSIRIS and VISION for eyes, and nanoDot for body, neck, and eyes was exposed to 99mTc, 123I, and 18F radionuclides. Sealed syringe sources of each radionuclide were positioned 30 cm from the abdomen of the phantom. Estimated exposure based on measurement conditions (i.e., air kerma rate constants, conversion coefficient, distance, activity, and exposure time) was compared measured dose equivalent of each dosimeter. Differences in body, neck, and eye lens dosimeters were statistically analyzed. The 10‐mm dose equivalent significantly differed between the Glass Badge and Luminess Badge for the neck, but these were almost equivalent at the body. The 0.07‐mm dose equivalent for the nanoDot dosimeters was greatly overestimated compared to the estimated exposure of 99mTc and 123I radionuclides. Measured dose equivalents of exposure significantly differed between the body and eye lens dosimeters with respect to 18F. Although accurately measuring radiation exposure to the eye lenses of nuclear medicine staff is conventionally monitored using dosimeters worn on the chest or abdomen, eye lens dosimeters that provide a 3‐mm dose equivalent near the eye would be a more reliable means of assessing radiation doses in the mixed radiation environment of nuclear medicine.
Collapse
Affiliation(s)
- Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
| | - Takashi Iimori
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | - Kei Wagatsuma
- School of Allied Health Science, Kitasato University, Kanagawa, Japan
| | - Hiroyuki Tsushima
- Department of Radiological Technology, Faculty of Health Sciences, Kobe Tokiwa University, Hyogo, Japan
| | - Noriyo Yokotsuka
- Department of Radiological Technology, Faculty of Medical Technology, Teikyo University, Tokyo, Japan
| | - Taisuke Murata
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | | | - Takashi Terauchi
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| |
Collapse
|
5
|
Ito H, Matsubara K, Kobayashi I, Sakai T, Isobe T, Yanagawa N, Ochi S. Usefulness of a lead-acrylic shield for reducing lens dose of assistant in x-ray CT examination. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2022; 42:021529. [PMID: 35705067 DOI: 10.1088/1361-6498/ac7919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 06/15/2022] [Indexed: 06/15/2023]
Abstract
In computed tomography (CT) examinations, the usefulness of protective glasses for reducing lens exposure to assistants has been reported. The present study aimed to compare the dose reduction effect for assistants with lead-acrylic shields and protective glasses (0.07 mm Pb, 0.5 mm Pb) during CT examination. The air dose distribution in a CT examination room with and without a lead-acrylic shield was compared. It was found that the amount of scattered radiation was significantly reduced by installing a lead-acrylic shield at the CT gantry aperture. Moreover, the reduction rate of air kerma at the assistant's lens was higher using the lead acrylic shield than with the protective glasses-95.7% during head holding and 76.1% during assisted ventilation.
Collapse
Affiliation(s)
- Hajime Ito
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2 Okayamadai, Togane, Chiba 283-8686, Japan
- Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan
| | - Kosuke Matsubara
- Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan
| | - Ikuo Kobayashi
- Research Institute of Nuclear Engineering, University of Fukui, 1-3-33 Kanawa, Tsuruga, Fukui 914-0055, Japan
| | - Takayuki Sakai
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2 Okayamadai, Togane, Chiba 283-8686, Japan
| | - Tomonori Isobe
- Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan
| | - Noriyuki Yanagawa
- Department of Radiological Technology, Faculty of Health Sciences, Tsukuba International University, 6-20-1 Manabe, Tsuchiura, Ibaraki 300-0051, Japan
| | - Shigehiro Ochi
- Department of Radiology, Eastern Chiba Medical Center, 3-6-2 Okayamadai, Togane, Chiba 283-8686, Japan
| |
Collapse
|
6
|
Chida K. What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel? Radiol Phys Technol 2022; 15:101-115. [PMID: 35608759 DOI: 10.1007/s12194-022-00660-8] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 04/20/2022] [Accepted: 04/20/2022] [Indexed: 11/24/2022]
Abstract
Protection against occupational radiation exposure in clinical settings is important. This paper clarifies the present status of medical occupational exposure protection and possible additional safety measures. Radiation injuries, such as cataracts, have been reported in physicians and staff who perform interventional radiology (IVR), thus, it is important that they use shielding devices (e.g., lead glasses and ceiling-suspended shields). Currently, there is no single perfect radiation shield; combinations of radiation shields are required. Radiological medical workers must be appropriately educated in terms of reducing radiation exposure among both patients and staff. They also need to be aware of the various methods available for estimating/reducing patient dose and occupational exposure. When the optimizing the dose to the patient, such as eliminating a patient dose that is higher than necessary, is applied, exposure of radiological medical workers also decreases without any loss of diagnostic benefit. Thus, decreasing the patient dose also reduces occupational exposure. We propose a novel four-point policy for protecting medical staff from radiation: patient dose Optimization, Distance, Shielding, and Time (pdO-DST). Patient dose optimization means that the patient never receives a higher dose than is necessary, which also reduces the dose received by the staff. The patient dose must be optimized: shielding is critical, but it is only one component of protection from radiation used in medical procedures. Here, we review the radiation protection/reduction basics for radiological medical workers, especially for IVR staff.
Collapse
Affiliation(s)
- Koichi Chida
- Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba-ku, Sendai, 980-8575, Japan. .,Division of Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, 468-1 Aoba, Aramaki, Aoba-ku, Sendai, 980-8572, Japan.
| |
Collapse
|