1
|
Tatry M, Bastelica P, Brasnu E, Buffault J, Hamard P, Baudouin C, Labbé A. [Glaucoma surgeries: Long-term results - A review]. J Fr Ophtalmol 2024; 47:104098. [PMID: 39208602 DOI: 10.1016/j.jfo.2024.104098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 08/12/2023] [Accepted: 08/31/2023] [Indexed: 09/04/2024]
Abstract
The surgical treatment of glaucoma has been and is still based on filtering surgeries, commonly used for about half a century. The safety and efficacy of these techniques have been well described, as it has also been done for cyclophotocoagulation and valves or tubes, indicated in France mostly for refractory glaucoma. Minimally invasive glaucoma surgeries have emerged in recent decades, increasing the number of therapeutic options, and allowing treatment decisions to be as patient-centered as possible. Most of these techniques have now been studied for more than five years. Since glaucoma is a chronic, progressive optic neuropathy, the sustainability of each surgery's results is essential. The amount of available data concerning long-term efficacy and safety of glaucoma surgeries is increasing, so we have decided to describe it through this review of the literature.
Collapse
Affiliation(s)
- M Tatry
- Service 3, IHU FOReSIGHT, hôpital national de la vision des 15-20, Paris, France.
| | - P Bastelica
- Service 3, IHU FOReSIGHT, hôpital national de la vision des 15-20, Paris, France; Institut de la Vision, IHU FOReSIGHT, Sorbonne Université, Paris, France
| | - E Brasnu
- Service 3, IHU FOReSIGHT, hôpital national de la vision des 15-20, Paris, France; Institut de la Vision, IHU FOReSIGHT, Sorbonne Université, Paris, France; Inserm 1423, IHU FOReSIGHT, hôpital national de la vision, centre d'investigation clinique, Paris, France
| | - J Buffault
- Service 3, IHU FOReSIGHT, hôpital national de la vision des 15-20, Paris, France; Institut de la Vision, IHU FOReSIGHT, Sorbonne Université, Paris, France; IHU FOReSIGHT, hôpital Ambroise-Paré, AP-HP, université de Versailles Saint-Quentin-en-Yvelines, Versailles, France; Inserm 1423, IHU FOReSIGHT, hôpital national de la vision, centre d'investigation clinique, Paris, France
| | - P Hamard
- Service 3, IHU FOReSIGHT, hôpital national de la vision des 15-20, Paris, France
| | - C Baudouin
- Service 3, IHU FOReSIGHT, hôpital national de la vision des 15-20, Paris, France; Institut de la Vision, IHU FOReSIGHT, Sorbonne Université, Paris, France; IHU FOReSIGHT, hôpital Ambroise-Paré, AP-HP, université de Versailles Saint-Quentin-en-Yvelines, Versailles, France; Inserm 1423, IHU FOReSIGHT, hôpital national de la vision, centre d'investigation clinique, Paris, France
| | - A Labbé
- Service 3, IHU FOReSIGHT, hôpital national de la vision des 15-20, Paris, France; Institut de la Vision, IHU FOReSIGHT, Sorbonne Université, Paris, France; IHU FOReSIGHT, hôpital Ambroise-Paré, AP-HP, université de Versailles Saint-Quentin-en-Yvelines, Versailles, France; Inserm 1423, IHU FOReSIGHT, hôpital national de la vision, centre d'investigation clinique, Paris, France
| |
Collapse
|
2
|
Vizzari G, Ceruti P. Effectiveness and safety of istent inject as an interventional glaucoma approach for uncontrolled open-angle glaucoma. Eur J Ophthalmol 2024:11206721241272224. [PMID: 39105221 DOI: 10.1177/11206721241272224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/07/2024]
Abstract
INTRODUCTION To describe the results of iStent inject implantation as a standalone procedure in early-stage uncontrolled glaucoma, with results up to 24 months. METHODS A retrospective, single-center case series that recruited patients with open-angle glaucoma (OAG), uncontrolled IOP (defined as ≥18 mmHg), and who are receiving 1-4 glaucoma medications were implanted the iStent inject as a standalone procedure. Exclusion criteria were the contraindications of iStent inject implantation. Primary outcome measures were IOP at 6, 12, 18, and 24 months compared to baseline, and the number of medications at baseline and 24 months. RESULTS Eighty-eight eyes from 88 patients, aged 57.6 ± 9.8 years, were included. Ten eyes underwent a subsequent glaucoma procedure during follow-up and were excluded from the analysis. The mean IOP (mmHg) was reduced from 20.54 ± 1.42 at baseline to 15.99 ± 1.98 and 16.15 ± 2.21 (n = 78, p < 0.001) at the 12- and 24-month follow-up, respectively, and the mean number of medications was reduced from 2.35 ± 0.70 to 1.31 ± 0.80 (p < 0.001) at 24 months. Of those eyes, 59% had ≥20% reduction in IOP at 24 months, 91% had an IOP ≤18 mmHg at 24 months, and 71.8% were receiving fewer medications. At 24 months, 14.1% of eyes were medication-free, compared to none at baseline. No serious intraoperative or postoperative adverse events occurred. DISCUSSION iStent inject can effectively control intraocular pressure in mild glaucoma, reducing medication reliance and improving patient quality of life.
Collapse
Affiliation(s)
- Gabriele Vizzari
- Department of Ophthalmology, Hospital Mater Salutis Legnago, Legnago, Verona, Italy
| | - Piero Ceruti
- Department of Ophthalmology, Hospital Mater Salutis Legnago, Legnago, Verona, Italy
| |
Collapse
|
3
|
Gong Z, Johnstone MA, Wang RK. iStent insertion orientation and impact on trabecular meshwork motion resolved by optical coherence tomography imaging. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:076008. [PMID: 39070082 PMCID: PMC11283271 DOI: 10.1117/1.jbo.29.7.076008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 07/02/2024] [Accepted: 07/03/2024] [Indexed: 07/30/2024]
Abstract
Significance The iStent is a popular device designed for glaucoma treatment, functioning by creating an artificial fluid pathway in the trabecular meshwork (TM) to drain aqueous humor. The assessment of iStent implantation surgery is clinically important. However, current tools offer limited information. Aim We aim to develop innovative assessment strategies for iStent implantation using optical coherence tomography (OCT) to evaluate the position and orientation of the iStent and its biomechanical impact on outflow system dynamics. Approach We examined four iStents in the two eyes of a glaucoma patient. Three-dimensional (3D) OCT structural imaging was conducted for each iStent, and a semi-automated algorithm was developed for iStent segmentation and visualization, allowing precise measurement of position and orientation. In addition, phase-sensitive OCT (PhS-OCT) imaging was introduced to measure the biomechanical impact of the iStent on the outflow system quantified by cumulative displacement (CDisp) of pulse-dependent trabecular TM motion. Results The 3D structural image processed by our algorithm definitively resolved the position and orientation of the iStent in the anterior segment, revealing substantial variations in relevant parameters. PhS-OCT imaging demonstrated significantly higher CDisp in the regions between two iStents compared to locations distant from the iStents in both OD ( p = 0.0075 ) and OS ( p = 0.0437 ). Conclusions Our proposed structural imaging technique improved the characterization of the iStent's placement. The imaging results revealed inherent challenges in achieving precise control of iStent insertion. Furthermore, PhS-OCT imaging unveiled potential biomechanical alterations induced by the iStent. This unique methodology shows potential as a valuable clinical tool for evaluating iStent implantation.
Collapse
Affiliation(s)
- Zhaoyu Gong
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
| | - Murray A. Johnstone
- University of Washington, Department of Ophthalmology, Seattle, Washington, United States
| | - Ruikang K. Wang
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
- University of Washington, Department of Ophthalmology, Seattle, Washington, United States
| |
Collapse
|
4
|
Kiramira D, Voßmerbäumer U, Pfeiffer N, Linnerth-Braun LKM, Lorenz K, Prokosch V. Mid-term real world outcomes of the Hydrus ® Microstent in open angle glaucoma. Eye (Lond) 2024; 38:1454-1461. [PMID: 38182656 PMCID: PMC11126590 DOI: 10.1038/s41433-023-02920-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 11/15/2023] [Accepted: 12/20/2023] [Indexed: 01/07/2024] Open
Abstract
PURPOSE To evaluate the mid-term clinical results and the safety aspects of the Hydrus® Microstent (Ivantis, Inc, Irvine, CA) in a real-life setting. DESIGN Retrospective case series. METHODS Hydrus® Microstent was implanted in phakic eyes (88 eyes, 87.1%) and in pseudophakic eyes (13 eyes, 12.9%), respectively. Mean follow-up time was 16 ± 9 months with 27 eyes having a follow-up time of more than 24 months. MAIN OUTCOME MEASURES The primary endpoint was reduction in IOP compared to baseline. Target IOP levels were set at ≤20 mmHg, ≤18 mmHg and ≤15 mmHg. Kaplan-Meier survival was defined as a reduction in IOP of ≥20% compared to baseline. Secondary endpoints were reduction in number of glaucoma medications and safety assessments addressing visual acuity, adverse events, re-surgery rate and identification of factors that made the implantation more difficult. RESULT 101 eyes underwent Hydrus® implantation. The mean preoperative IOP was 21.60 mmHg (SD 6.6) on 2.18 (SD 1.3) medications. After a mean follow up time of 16 months, the mean IOP was reduced to 14.61 ± 3.7 mmHg on 1.12 (SD 1.1) medication classes (p < 0.001). Mean decrease in IOP was 26.7%. Analysis of the target IOP levels showed that in 29%, 34% and 35% of cases an IOP of ≤15 mmHg, ≤18 mmHg and ≤20 mmHg respectively could be achieved. BCVA improved from 0.56 ± 0.3 at baseline to 0.85 ± 0.3 more than 24 months after surgery (p < 0.001). The rate of re-operation was low at <3%. Adverse events occurred in 4 eyes (<4%). CONCLUSION This study underlines the effectiveness and the safety of the Hydrus® Microstent in an elective setting, but it also demonstrates certain limits and risk factors of this procedure.
Collapse
Affiliation(s)
- David Kiramira
- Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University, Mainz, Germany
- Department of Periodontology and Operative Dentistry, University Medical Center, Johannes Gutenberg-University, Mainz, Germany
| | - Urs Voßmerbäumer
- Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University, Mainz, Germany
- Frankfurt Hoechst Eye Hospital, Frankfurt, Germany
| | - Norbert Pfeiffer
- Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University, Mainz, Germany
| | - Lea K M Linnerth-Braun
- Department of Periodontology and Operative Dentistry, University Medical Center, Johannes Gutenberg-University, Mainz, Germany
| | - Katrin Lorenz
- Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University, Mainz, Germany
| | - Verena Prokosch
- Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University, Mainz, Germany.
- Department of Ophthalmology, University Hospital of Cologne, Cologne, Germany.
| |
Collapse
|
5
|
Hengerer FH, Auffarth GU, Conrad-Hengerer I. 7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage. Adv Ther 2024; 41:1481-1495. [PMID: 38363465 PMCID: PMC10960914 DOI: 10.1007/s12325-024-02788-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/17/2024] [Indexed: 02/17/2024]
Abstract
INTRODUCTION This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma. METHODS This prospective, non-randomized, unmasked, longitudinal study included 125 consecutive iStent inject cases of a single surgeon at a large German academic hospital. Patients had considerable preoperative disease burden, with mean intraocular pressure (IOP) of 23.5 mmHg, 84.8% of eyes on ≥ 2 medications, and 38.4% of eyes with prior glaucoma surgery. IOP, medications, adverse events, and secondary surgeries were assessed through 7 years in the Overall cohort and in Combined (n = 81) and Standalone (n = 44) subgroups. RESULTS Over 7-year follow-up, mean IOP decreased by 36.2-40.0% in Overall eyes, 34.1-38.9% in Combined eyes, and 39.5-43.5% in Standalone eyes (p < 0.001 at all timepoints for all groups). Meanwhile, mean medications decreased by 59.3-71.3% in Overall eyes, 57.9-69.0% in Combined eyes, and 62.1-76.2% in Standalone eyes (p < 0.001 at all timepoints in all groups). At last follow-up (mean 77.4 months; 92.8% of patients with last visit at 6 or 7 years), 83.7% of Overall eyes, 82.3% of Combined eyes, and 86.4% of Standalone eyes had achieved ≥ 20% IOP reduction vs preoperative. At last follow-up vs preoperative, 100% of eyes in all groups had the same or lower IOP and 100% had the same or lower medication regimen. Safety outcomes were favorable, with no filtration surgeries and only 4.84% of eyes experiencing clinically significant visual field loss over 7 years of follow-up. CONCLUSION iStent inject implantation with or without phacoemulsification produced significant and durable 7-year reductions in IOP (~ 34-44% reduction) and medications (~ 58-76% reduction) while preventing filtering surgery in this cohort of patients with relatively high preoperative disease burden. Combined and Standalone cases had similarly favorable effectiveness and safety.
Collapse
Affiliation(s)
- Fritz H Hengerer
- David J Apple International Laboratory of Ophthalmic Pathology, Department of Ophthalmology, International Vision Correction Research Centre (IVCRC), Buergerhospital, University of Heidelberg, Frankfurt, Germany.
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Ina Conrad-Hengerer
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
6
|
Fang Z, Bi S, Brown JD, Chen J, Pan T. Microfluidics in the eye: a review of glaucoma implants from an engineering perspective. LAB ON A CHIP 2023; 23:4736-4772. [PMID: 37847237 DOI: 10.1039/d3lc00407d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
Glaucoma is a progressive optic neuropathy in the eye, which is a leading cause of irreversible blindness worldwide and currently affects over 70 million individuals. Clinically, intraocular pressure (IOP) reduction is the only proven treatment to halt the progression of glaucoma. Microfluidic devices such as glaucoma drainage devices (GDDs) and minimally invasive glaucoma surgery (MIGS) devices are routinely used by ophthalmologists to manage elevated IOP, by creating an artificial pathway for the over-accumulated aqueous humor (AH) in a glaucomatous eye, when the natural pathways are severely blocked. Herein, a detailed modelling and analysis of both the natural microfluidic pathways of the AH in the eye and artificial microfluidic pathways formed additionally by the various glaucoma implants are conducted to provide an insight into the causes of the IOP abnormality and the improvement schemes of current implant designs. The mechanisms of representative glaucoma implants have been critically reviewed from the perspective of microfluidics, and we have categorized the current implants into four groups according to the targeted drainage sites of the AH, namely Schlemm's canal, suprachoroidal space, subconjunctival space, and ocular surface. In addition, we propose to divide the development and evolution of glaucoma implant designs into three technological waves, which include microtube (1st), microvalve (2nd) and microsystem (3rd). With the emerging trends of minimal invasiveness and artificial intelligence in the development of medical implants, we envision that a comprehensive glaucoma treatment microsystem is on the horizon, which is featured with active and wireless control of IOP, real-time continuous monitoring of IOP and aqueous rate, etc. The current review could potentially cast light on the unmatched needs, challenges, and future directions of the microfluidic structural and functional designs of glaucoma implants, which would enable an enhanced safety profile, reduced complications, increased efficacy of lowering IOP and reduced IOP fluctuations, closed-loop and on-demand control of IOP, etc.
Collapse
Affiliation(s)
- Zecong Fang
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
| | - Shuzhen Bi
- Center for Intelligent Medical Equipment and Devices (iMED), University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
| | | | - Junyi Chen
- Department of Ophthalmology and Visual Science, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia, Chinese Academy of Medical Sciences, and Shanghai Key Laboratory of Visual Impairment and Restoration (Fudan University), Shanghai, 200031, China
| | - Tingrui Pan
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
- Center for Intelligent Medical Equipment and Devices (iMED), University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui, 230026, China
| |
Collapse
|
7
|
Ang BCH, Chen EJ. Novel surgical technique to manage iStent inject over-implantation. Eur J Ophthalmol 2023; 33:2309-2312. [PMID: 37549939 DOI: 10.1177/11206721231190417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
PURPOSE To describe a novel surgical technique to manage over-implantation of the iStent inject intra-operatively, utilizing only the iStent inject delivery system itself to perform both device extraction and reimplantation, without the need for additional instrumentation. METHODS A demonstration of managing over-implantation of the iStent inject, with two case examples. RESULTS Over-implantation of the iStent inject can be successfully managed intra-operatively to ensure ideal positioning to optimise post-operative outcomes, with the use of only the iStent inject delivery system itself for both device extraction and reimplantation. CONCLUSION This novel technique provides a cost-effective and feasible means to intra-operatively manage over-implantation of the iStent inject.
Collapse
Affiliation(s)
- Bryan Chin Hou Ang
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | - Elizabeth Jiahui Chen
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| |
Collapse
|
8
|
Laroche D, Madu CT. Preventing Blindness with Early Cataract Surgery and Micro-Invasive Glaucoma Surgery in Patients Over 50: Guidance for Patients, Physicians and World Governments in Dealing with Glaucoma. Clin Ophthalmol 2023; 17:2929-2938. [PMID: 37814637 PMCID: PMC10560466 DOI: 10.2147/opth.s422415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 09/25/2023] [Indexed: 10/11/2023] Open
Abstract
Purpose To offer clinical guidance and address safety and efficacy concerns regarding the growing use of micro-invasive glaucoma surgery (MIGS) as an initial treatment for glaucoma in adult patients. Design Narrative literature review. Methods A review was conducted to assess outcomes and complications of MIGS in the treatment of glaucoma, both alone and in combination with lens replacement. These outcomes were compared with those of standard glaucoma surgery and/or glaucoma management with medication. Results MIGS are effective at lowering intraocular pressure (IOP) over long periods of follow-up. These techniques share a similarly high safety profile between one another. MIGS were found to have lower complication rates and to be more effective in reducing the total amount of medication needed to maintain control of intraocular pressure than standard surgery approaches. Conclusion MIGS techniques are growing in popularity and have been demonstrated to be a safe and effective alternative to standard glaucoma surgery. Guidance in the implementation of these procedures has been outlined.
Collapse
Affiliation(s)
- Daniel Laroche
- Department of Ophthalmology, New York Eye and Ear Infirmary, Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Advanced Eye Care of New York, New York, NY, USA
| | - Chisom T Madu
- City University of New York School of Medicine, New York, NY, USA
| |
Collapse
|
9
|
Kanda S, Fujishiro T, Karakawa A, Nakagawa S, Ishii K. Clinical Outcomes of Phacoemulsification in Japanese Patients Receiving First and Revised Second-Generation Trabecular Microbypass Stents. Asia Pac J Ophthalmol (Phila) 2023; 12:279-283. [PMID: 37171124 DOI: 10.1097/apo.0000000000000611] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 03/28/2023] [Indexed: 05/13/2023] Open
Abstract
PURPOSE This study evaluated the effectiveness and safety of first and revised second-generation trabecular microbypass stent insertion [iStent (IS) and iStent inject W (IW)] in cataract surgery. DESIGN Single-center, retrospective, cohort study. METHODS The study included 176 eyes that received trabecular microbypass stents combined with cataract surgery at the Saitama Red Cross Hospital between September 2017 and September 2021. Patients were divided into IS and IW groups depending on the implant type. Demographic characteristics, intraocular pressure (IOP), and the number of antiglaucoma medications (Med) were analyzed preoperatively and 12 months postoperatively. In addition, postoperative complications were compared between the groups. RESULTS IS and IW were implanted in 86 eyes and 90 eyes, respectively. IOP and Med at 1, 3, 6, 9, and 12 months decreased significantly from baseline in both groups ( P = 0.04, P < 0.001, P < 0.001, P < 0.001, and P < 0.001, respectively, for IOP in the IS group; P = 0.02, P < 0.001, P < 0.001, P < 0.001, and P < 0.001, respectively, for IOP in the IW group; P = 0.03, P = 0.002, P < 0.001, P < 0.001, and P < 0.001, respectively, for Med in the IS group; and P < 0.001 for all time points for Med in the IW group). IOP did not vary significantly between the groups at 1, 3, 6, 9, and 12 months postoperatively. Med was significantly lower in IW than IS at 1, 3, 6, 9, and 12 months postoperatively ( P < 0.001, P < 0.001, P = 0.002, P = 0.002, and P = 0.002, respectively). Hyphema and IOP >30 mm Hg (spike) occurred in 1.2% and 4.4%, and 1.2% and 3.3% of patients in the IS and IW groups, respectively. The probability of successful discontinuation of medications at 12 months postoperatively was 10.5% and 41.1%, respectively ( P < 0.001). CONCLUSIONS Postoperative Med was significantly lower in the IW group. Simultaneous insertion of IW in patients with glaucoma requiring cataract surgery may be preferred to IS because it reduces the burden of Med.
Collapse
Affiliation(s)
- Satoru Kanda
- Saitama Red Cross Hospital, Department of Ophthalmology, University of Tokyo, Tokyo, Japan
| | - Takashi Fujishiro
- The University of Tokyo Hospital, Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Ayako Karakawa
- Saitama Red Cross Hospital, Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Suguru Nakagawa
- Saitama Red Cross Hospital, Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Kiyoshi Ishii
- Saitama Red Cross Hospital, Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
10
|
Droste AP, Newman-Casey PA. Emerging glaucoma treatments: are we seeing an improvement in adherence? EXPERT REVIEW OF OPHTHALMOLOGY 2023; 18:101-111. [PMID: 37520660 PMCID: PMC10373909 DOI: 10.1080/17469899.2023.2199981] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 04/03/2023] [Indexed: 08/01/2023]
Abstract
Introduction Non-adherence to glaucoma medication and poor follow-up is a global health concern. Areas covered Glaucoma remains one of the largest causes of irreversible blindness worldwide. Traditional treatment guidelines suggest topical eye drop medication as first line therapy followed by addition of supplementary medications before proceeding to more invasive glaucoma surgeries. Unfortunately, poor glaucoma self-management remains high, leading to disease progression and blindness. Recent advancements in the field of pharmacotherapies, surgeries, and behavioral approaches have taken aim at increasing support for glaucoma self-management. We review the current and emerging approaches towards glaucoma management, with the exception of bleb-based surgical approaches, to investigate if they have had an impact on adherence. Literature searches were conducted via MEDLINE (PubMed), Embase (Elsevier), Cochrane Library (Wiley), and Preprints from January 1st, 2018, to January 26th, 2023. Expert opinion The ability to offer patients a multitude of choices enables patients to tailor their glaucoma treatment to their values and lifestyle. Offering personalized patient education and coaching to support chronic glaucoma self-management would better enable patient engagement in whichever treatment path is chosen. Currently, literature regarding the impact of these new advancements on treatment engagement is lacking; this field is ripe for additional intervention and assessment.
Collapse
Affiliation(s)
- Andrew P Droste
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, MI, USA
| | | |
Collapse
|
11
|
Risk factors and management of choroidal effusions. Curr Opin Ophthalmol 2023; 34:162-167. [PMID: 36730733 DOI: 10.1097/icu.0000000000000929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE OF REVIEW Choroidal effusions are recognized as a common early postoperative complication of glaucoma surgery, and although often benign, they may cause significant ocular morbidity. This article aims to summarize current research on the risk factors and management of choroidal effusions. RECENT FINDINGS Glaucoma drainage device (GDD) implantation and trabeculectomy are the most commonly performed surgeries for the management of moderate to severe glaucoma. Common postoperative complications of these procedures include hypotony and the development of choroidal effusions. Choroidal effusions have recently been associated with the oral administration of certain drugs, including select monoclonal antibody, antiseizure and bisphosphonate medications. Risk factors for effusion development include specific patient characteristics such as pseudoexfoliative glaucoma, older age and hypertension. Although choroidal effusions typically resolve with medical therapy alone, surgical intervention may be required. Various methods of surgical intervention, such as surgical drainage or GDD tube ligation, can be utilized to treat choroidal effusions when conservative management with medical treatment fails, but themselves carry alternative risks that must be considered. SUMMARY Minimizing the incidence and duration of hypotony following ophthalmic surgery and careful monitoring of patients starting certain oral medications are important in limiting the occurrence of choroidal effusions. Risk factors for choroidal effusions have been recently identified in the literature. A better understanding of these risk factors, as well as the outcomes of choroidal effusion management, can help to reduce the occurrence of effusions overall and minimize ocular morbidity.
Collapse
|
12
|
Feinberg L, Swampillai AJ, Byles D, Smith M. Six year outcomes of combined phacoemulsification surgery and endoscopic cyclophotocoagulation in refractory glaucoma. Graefes Arch Clin Exp Ophthalmol 2022; 261:1339-1347. [PMID: 36482212 DOI: 10.1007/s00417-022-05906-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 10/13/2022] [Accepted: 11/08/2022] [Indexed: 12/13/2022] Open
Abstract
PURPOSE This study is to describe the 6-year results of combined phacoemulsification surgery and endoscopic cyclophotocoagulation (Phaco-ECP) surgery in patients with uncontrolled glaucoma and no previous glaucoma surgery. METHODS This is a retrospective case series of 84 eyes. The primary outcome measure was intraocular pressure (IOP) reduction 6 years postoperatively. Secondary outcome measures were the cumulative probability of failure of the surgical procedure at 6 years. Failure was defined as IOP higher than 21 mm Hg or lower than 6 mm Hg or IOP not reduced by 20% from baseline at the 1, 2, 3, 4, 5, or 6-year time points or further laser or other surgery to reduce IOP at any timepoint. RESULTS There was a statistically significant decrease in mean IOP from 18.9 mmHg pre-operatively to 13.7, 12.8, 13.0, 12.7, 12.5, and 12.3 mmHg at the 1, 2, 3, 4, 5, and 6 years post-operatively respectively (p < 0.001). Fifty-seven (68%) reached criteria for failure by 6 years. In 36% of cases, this was due to inadequate IOP control, whereas 32% required further laser or surgery. When we excluded patients who only had selective laser trabeculoplasty rather than further surgery, the failure rate reduced to 51%. Eleven percent had a post-operative complication, 2.4% requiring further surgical intervention. CONCLUSIONS At 6 years postoperatively, combined phaco-ECP achieved a significant reduction in IOP in patients with uncontrolled glaucoma and no previous drainage surgery. Significant complications were uncommon, but 68% was classified as surgical failures by the six year point.
Collapse
Affiliation(s)
- Leo Feinberg
- West of England Eye Unit, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, EX2 5DW, Devon, UK.
| | - Andrew J Swampillai
- West of England Eye Unit, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, EX2 5DW, Devon, UK
| | - Daniel Byles
- West of England Eye Unit, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, EX2 5DW, Devon, UK
| | - Michael Smith
- West of England Eye Unit, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, EX2 5DW, Devon, UK
| |
Collapse
|
13
|
Lima FE, Geraissate JC, Ávila MP. A multicenter prospective comparative study evaluating cataract surgery and endoscopic cyclophotocoagulation either with or without iStent inject implantation in Brazilian patients with glaucoma. Int Ophthalmol 2022; 43:1665-1676. [PMID: 36273360 PMCID: PMC10149466 DOI: 10.1007/s10792-022-02563-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 10/10/2022] [Indexed: 11/24/2022]
Abstract
Abstract
Purpose
Compare 12-month (12 M) safety and efficacy of endoscopic cyclophotocoagulation (ECP) + cataract surgery (Group 1) versus ECP + cataract surgery + iStent inject trabecular micro-bypass implantation (Group 2) in Brazilian patients with open-angle glaucoma (OAG).
Methods
This prospective, multicenter, comparative case series included patients with OAG and cataract who were randomized to receive treatment in Group 1 or Group 2. Outcomes included mean and percent reduction versus preoperative in intraocular pressure (IOP) and number of glaucoma medications; visual acuity; occurrence of adverse events; and rate of secondary surgeries.
Results
Preoperatively, Groups 1 and 2 had similar mean IOP (mean ± standard deviation 22.1 ± 3.6 and 22.0 ± 2.5 mmHg, respectively) and mean number of medications (3.3 ± 0.6 and 3.4 ± 0.6 medications, respectively). At all follow-up timepoints through 12 M, both groups achieved significant IOP and medication reductions versus preoperative (IOP p < 0.001 and number of medications p < 0.001 for both groups). At 12 M, IOP reductions were 24.2% (Group 1) and 43.6% (Group 2) (p < 0.001); mean medication reductions were 50.2% and 71.5%, respectively. Mean postoperative IOP and number of medications were higher in Group 1 than Group 2 (IOP p < 0.01 all visits, medication p < 0.01 at 6 M and 12 M). Adverse events were generally mild and infrequent in both groups.
Conclusion
Both treatment groups (ECP + phacoemulsification, with/without iStent inject implantation) achieved significant and safe reductions in IOP and medications versus preoperative in Brazilian OAG patients. Percent reductions were significantly greater, and mean IOP and medications were significantly lower, in the group receiving iStent inject.
Clinical trial registration (CTR)
CAAE project identification #20053019.5.0000.5078. Protocol #3.587.147. Clinical Trial Database of the Federal University of Goiás, Brazil. Registration Date: September 19, 2019.
Collapse
Affiliation(s)
- Francisco E. Lima
- Federal University of Goiás, Goiânia, Brazil
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
| | - João C. Geraissate
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
- Centro Brasileiro da Visão, Brasília, Brazil
| | - Marcos P. Ávila
- Federal University of Goiás, Goiânia, Brazil
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
- Centro Brasileiro da Visão, Brasília, Brazil
| |
Collapse
|
14
|
Clement C, Howes F, Ioannidis A, Shiu M, Manning D, Lusthaus JA, Skalicky SE, Goodwin TW. Multicenter Effectiveness and Disease Stability Through 3 Years After iStentTrabecular Micro-Bypass with Phacoemulsification in Glaucoma and Ocular Hypertension. Clin Ophthalmol 2022; 16:2955-2968. [PMID: 36071724 PMCID: PMC9444145 DOI: 10.2147/opth.s373290] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To evaluate 3-year safety and efficacy of two second-generation trabecular micro-bypass stents. (iStent inject®) with phacoemulsification. Materials and Methods This multicenter retrospective study of iStent inject implantation with phacoemulsification included data from eight surgeons across Australia. Eyes with cataract and mild to advanced glaucoma [predominantly primary open-angle (POAG), primary angle closure (PAC), or normal-tension (NTG) glaucoma] or ocular hypertension (OHT) were included. Study assessments included intraocular pressure (IOP); number of ocular hypotensive medications; proportions of eyes with 0, 1, 2, or ≥3 IOP-lowering medications; IOP ≤15 mmHg or ≤18 mmHg; visual fields (VF); retinal nerve fiber layer thickness (RNFL); central corneal thickness (CCT); intraoperative complications; adverse events; and secondary surgeries. Results A total of 273 eyes underwent surgery and had 36-month follow-up. At 36 months versus preoperative, mean IOP decreased by 15.5% (16.4±4.6 mmHg to 13.9±3.5 mmHg; p<0.001), and 70.3% of eyes achieved IOP of ≤15 mmHg (versus 49.1% preoperatively; p<0.001). The mean medication burden decreased by 68.5% (from 1.51±1.17 to 0.48±0.89 medications; p<0.001); 71.4% of eyes were medication-free (versus 21.6% preoperatively; p<0.001), while 6.2% of eyes were on ≥3 medications (versus 22.3% preoperatively; p<0.001); 96.3% of eyes maintained or reduced medications vs preoperative. Significant IOP and medication reductions occurred across glaucoma subtypes (POAG, PAC, NTG, OHT): 13–22% for IOP (p<0.05 for all) and 42–94% for medication (p<0.05 for all). Favorable safety included few adverse events; stable VF, RNFL, and CCT; and filtering surgery in only 8 eyes (2.9%) over 3 years. Conclusion In this multicenter cohort from 8 surgeons across Australia, significant IOP and medication reductions were sustained through 3 years after iStent inject implantation with phacoemulsification. Results were favorable across different glaucoma subtypes (including POAG, PAC, NTG, OHT), severities, and surgeons, thereby underscoring the real-world relevance and efficacy of iStent inject implantation for glaucoma treatment.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia
- Fairfield Eye Surgery, Fairfield, NSW, Australia
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Correspondence: Colin Clement, Eye Associates, Level 4, 187 Macquarie Street, Sydney, NSW, 2000, Australia, Tel +612 9247 9972, Email
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed A Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Eyehaus, Sydney, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
15
|
Ang BCH, Chiew W, Yip VCH, Chua CH, Han WS, Tecson IOC, Ogle JJ, Lim BA, Hee OK, Tay ELY, Yong VKY, Wong HT, Yip LWL. Prospective 12-month outcomes of combined iStent inject implantation and phacoemulsification in Asian eyes with normal tension glaucoma. EYE AND VISION (LONDON, ENGLAND) 2022; 9:27. [PMID: 35794666 PMCID: PMC9258099 DOI: 10.1186/s40662-022-00294-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 06/04/2022] [Indexed: 11/17/2022]
Abstract
BACKGROUND Glaucoma is the leading cause of irreversible blindness. Normal tension glaucoma (NTG) is a subset of open-angle glaucoma, demonstrating glaucomatous optic nerve damage in the absence of raised intraocular pressure (IOP). NTG is more prevalent in Asian populations. While generally slow-progressing, NTG may be associated with significant central visual field loss. In recent years, minimally invasive glaucoma surgery has been added to the armamentarium of glaucoma surgery. This prospective study aims to evaluate 12-month surgical outcomes of combined iStent inject (Glaukos Corporation, Laguna Hills, CA) implantation and phacoemulsification in Asian eyes with NTG. METHODS This is a prospective, single-centre case series of 30 eyes followed up until 12 months after surgery. Outcome measures included IOP, number of glaucoma medications, best-corrected visual acuity (BCVA) and intra and postoperative complications. RESULTS Mean age of subjects was 73.1 ± 6.3 years. Majority were ethnic Chinese (n = 27, 90%). Baseline medicated mean IOP was 13.8 ± 2.4 mmHg and mean number of glaucoma medications was 1.3 ± 0.7. Mean Humphrey visual field mean deviation was - 13.7 ± 7.6. The mean IOP reduction at all timepoints from postoperative month (POM) 3 onwards was statistically significant (all P < 0.05), with mean reduction of 1.2 mmHg (95% CI: 0.1-2.2, P = 0.037) by POM12. There was statistically significant reduction in mean number of medications from postoperative day (POD) 1 onwards (all P < 0.05), with mean decrease of 1.0 medication (95% CI: 0.9-1.1, P < 0.001) by POM12. By POM12, 25 (83.3%) eyes were medication-free. Three (10%) eyes had stent occlusion by iris requiring laser iridoplasty. One eye had gross hyphema which resolved on conservative management before POM1. Mean BCVA improved from the baseline 0.3 ± 0.3 logMAR to 0.1 ± 0.1 logMAR postoperatively (P < 0.001). There were no major adverse or sight-threatening events. No eyes required further glaucoma surgery during the 12-month follow-up period. CONCLUSION Asian eyes with NTG which underwent combined iStent inject implantation and phacoemulsification demonstrated a significant and sustained reduction in IOP and glaucoma medications, up to 12 months postoperatively.
Collapse
Affiliation(s)
- Bryan Chin Hou Ang
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore.
- National Healthcare Group Eye Institute, Woodlands Health Campus, Singapore, Singapore.
| | - Wenqi Chiew
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Vivien Cherng Hui Yip
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | - Chun Hau Chua
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | - Wei Shan Han
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | - Ivan O'Neill C Tecson
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
- Cardinal Santos Medical Centre, Manila, Philippines
| | - Jeanne Joyce Ogle
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | - Boon Ang Lim
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | | | - Elton Lik Yong Tay
- National Healthcare Group Eye Institute, Woodlands Health Campus, Singapore, Singapore
| | - Vernon Khet Yau Yong
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | - Hon Tym Wong
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| | - Leonard Wei Leon Yip
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore, Singapore
| |
Collapse
|
16
|
Guedes RAP, Souza CP, Dias LLDS, Murta L, Gravina DM, Chaoubah A. A Brazilian cost-utility analysis of trabecular micro-bypass with iStent inject® for the treatment of open-angle glaucoma. REVISTA BRASILEIRA DE OFTALMOLOGIA 2022. [DOI: 10.37039/1982.8551.20220049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
17
|
Sigona M, Saravanan A, Pipis S, Masood I. Gonioscopy-assisted Transluminal Trabeculotomy Following Failed iStent Surgery. J Glaucoma 2022; 31:e83-e86. [PMID: 35658067 DOI: 10.1097/ijg.0000000000002058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 05/25/2022] [Indexed: 11/25/2022]
Abstract
We describe four cases of eyes initially treated with phacoemulsification and iStent trabecular micro-bypass (Glaukos Corporation, Laguna Hills, CA, USA). These patients subsequently required further surgery and were successfully treated with removal of the iStent device followed by Gonioscopy-assisted transluminal trabeculotomy (GATT) using the iTrack catheter (Ellex Medical Lasers Ltd., Adelaide, SA, Australia). Three of the cases had prior first-generation iStent (G1), and one had prior second-generation iStent (G2). This case series demonstrates that in selected cases a further angle procedure in the form of a GATT can show efficacy and durability in the medium term. Our patients had controlled intraocular pressures at one year post GATT; two on IOP-lowering therapy and two without any IOP-lowering medications. Three patients had transient hyphaema and two with high IOP in the immediate postoperative period. No patients experienced a decrease in BCVA postoperatively. To our knowledge, there is no prior literature describing this surgical strategy. This series demonstrates that GATT could potentially be an effective procedure in the case of a failed initial iStent microtrabecular bypass.
Collapse
Affiliation(s)
- Mark Sigona
- Birmingham Midland Eye Centre, SWBH NHS Trust, Birmingham Institute of Glaucoma Research, University Hospitals Birmingham NHS Foundation Trust
| | | | | | | |
Collapse
|
18
|
McNiel CL, Sanchez FG, Rees JP, Gardiner SK, Young JW, Kinast RM, Young A, Jones EP, Mansberger SL. Intraocular Pressure and Medication Burden With Cataract Surgery Alone, or Cataract Surgery Combined With Trabecular Bypass or Goniotomy. J Glaucoma 2022; 31:423-429. [PMID: 35353775 DOI: 10.1097/ijg.0000000000002028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 03/17/2022] [Indexed: 11/25/2022]
Abstract
PRCIS When compared with cataract surgery in glaucoma patients, trabecular micro-bypass and goniotomy resulted in a large decrease in the incidence of intraocular pressure (IOP) spikes, a modest effect on IOP, and a minimal effect on medication burden. PURPOSE To compare changes in IOP and ocular hypotensive medications in 3 surgical cohorts: cataract surgery, cataract surgery with trabecular micro-bypass (cataract/trabecular), and cataract surgery with goniotomy (cataract/goniotomy). MATERIALS AND METHODS We included 138 eyes diagnosed with open-angle glaucoma: (1) 84 eyes with cataract surgery alone, (2) 25 eyes with cataract/trabecular surgery, and (3) 29 eyes with cataract/goniotomy surgery. We compared the groups for postoperative IOP and the number of ocular hypotensive medications. We adjusted for preoperative IOP, and preoperative and postoperative number of ocular hypotensive medications. We defined an IOP spike as IOP ≥21 mm Hg and 10 mm Hg higher than preoperative on postoperative day 1. RESULTS All 3 surgeries showed a decrease in IOP (P≤0.004) and medication burden (P≤0.001) at 3 and 6 months postoperatively when compared with their own preoperative baselines. When compared with cataract surgery alone, cataract/trabecular and cataract/goniotomy had similar IOP lowering at 1 month postoperatively, and variable results at 3 and 6 months. The change in ocular hypotensive medications was not statistically different between the surgical groups at any postoperative visit. Cataract/trabecular and cataract/goniotomy decreased IOP on postoperative day 1, and had relative risk reduction of ~70% for IOP spikes (P≤0.001 for both). CONCLUSION Trabecular micro-bypass and goniotomy when added to cataract surgery resulted in a large decrease in IOP spikes, a modest effect on IOP, and a minimal effect on medication burden when compared with cataract surgery alone in glaucoma patients.
Collapse
Affiliation(s)
- Christopher L McNiel
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
- Department of Osteopathic Medicine, Western University of Health Sciences, Lebanon, OR
| | - Facundo G Sanchez
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
| | - Jack P Rees
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
| | - Stuart K Gardiner
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
| | - Jonathan W Young
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
| | - Robert M Kinast
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
| | - Amber Young
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
| | - Emily P Jones
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
| | - Steven L Mansberger
- Legacy Devers Eye Institute and Discoveries In Sight Research Laboratories at Legacy Health, Portland
| |
Collapse
|
19
|
Kan JT, Betzler BK, Lim SY, Ang BCH. Anterior segment imaging in minimally invasive glaucoma surgery - A systematic review. Acta Ophthalmol 2022; 100:e617-e634. [PMID: 34250742 DOI: 10.1111/aos.14962] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 06/17/2021] [Indexed: 12/13/2022]
Abstract
Minimally invasive glaucoma surgery (MIGS) has grown in popularity over the past decade. This systematic review explores the peri-operative and intraoperative application of anterior segment imaging to maximize the efficacy and safety of MIGS. A review of the PubMed, EMBASE and CINAHL databases was conducted, with inclusion criteria restricted to MIGS that had received United States Food and Drug Administration (FDA) premarket approval, FDA 510(K) premarket notification, or were listed as a class 1 device exempt from FDA approval or notification. 21 manuscripts from 21 unique studies were identified pertaining to MIGS devices including the XEN Gel Stent, Trabectome, iStent Inject, 1st-generation iStent and the Kahook Dual Blade (KDB). Anterior segment imaging modalities included anterior segment optical coherence tomography (AS-OCT), ultrasound biomicroscopy (UBM), aqueous angiography, OCT volumetric scans and in vivo confocal microscopy. Identification and evaluation of aqueous outflow pathways before and after MIGS have potential for improving patient preoperative patient selection and postoperative outcomes. Intraoperative imaging potentially provides the resolution needed for good visualization of angle anatomy and accurate evaluation of surgical endpoints in angle-based MIGS. Anterior segment imaging has been used to identify procedural complications, provide objective information on implant location in relation to surrounding anatomy, assess the post-implantation structural impact of MIGS devices and manage bleb failure and scarring. Technical difficulties in incorporating imaging modalities into the surgical microscope, variable quality of images and optical interference from ocular structures or surgical instruments are remaining barriers, which discourage the widespread clinical use of this technology.
Collapse
Affiliation(s)
- John Tsia‐Chuen Kan
- Department of Ophthalmology Tan Tock Seng Hospital National Healthcare Group Eye Institute Singapore Singapore
| | - Bjorn Kaijun Betzler
- Yong Loo Lin School of Medicine National University of Singapore Singapore Singapore
| | - Sheng Yang Lim
- Yong Loo Lin School of Medicine National University of Singapore Singapore Singapore
| | - Bryan Chin Hou Ang
- Department of Ophthalmology Tan Tock Seng Hospital National Healthcare Group Eye Institute Singapore Singapore
- Department of Ophthalmology Woodlands Health Campus National Healthcare Group Eye Institute Singapore Singapore
| |
Collapse
|
20
|
iStent inject Trabecular Micro-Bypass with or Without Cataract Surgery Yields Sustained 5-Year Glaucoma Control. Adv Ther 2022; 39:1417-1431. [PMID: 35113323 PMCID: PMC8918186 DOI: 10.1007/s12325-021-02039-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Accepted: 12/23/2021] [Indexed: 11/05/2022]
Abstract
Introduction This study evaluated the 5-year effectiveness and safety of iStent inject® trabecular micro-bypass with or without cataract surgery (Combined or Standalone, respectively) in patients with open-angle glaucoma (OAG). Methods This prospective longitudinal case series included consecutive iStent inject cases from a single surgeon at a large German academic hospital. Intraocular pressure (IOP), medications, safety, and indicators of disease stability through 5 years were assessed in the Overall cohort and in subgroup analyses stratified by usage (Combined or Standalone). Results Preoperative mean IOP in the Overall cohort (n = 125) was 23.5 ± 6.2 mmHg on 2.68 ± 1.02 mean medications, reducing to 14.1 ± 1.8 mmHg on 0.77 ± 0.82 medications at 5 years (40% and 71% reductions, respectively; both p < 0.001). All but 1 eye (> 99%) were on medication(s) preoperatively, but 46% were medication-free at 5 years (p < 0.001). In Combined eyes (n = 81), mean IOP decreased by 39% (22.6 mmHg to 13.8 mmHg, p < 0.001) and medications by 69% (2.52 to 0.78, p < 0.001). In Standalone eyes, mean IOP reduced by 42% (25.3 mmHg to 14.6 mmHg, p < 0.001) and medications by 75% (2.98 to 0.74, p < 0.001). At final follow-up, 83% of eyes had achieved ≥ 20% IOP reduction, and all but 1 eye (> 99%) had the same or lower IOP versus preoperative; all eyes (100%) maintained or reduced their medication burden versus preoperative. Favorable safety included 0 intraoperative complications and 0 filtration surgeries through 5 years. Long-term indicators of disease stability (visual fields, retinal nerve-fiber layer thickness, and cup:disc ratio) were unchanged over the course of 5-year follow-up. Conclusions iStent inject produced significant and durable 5-year reductions in IOP (nearly 10-mmHg reduction) and medications (nearly 2-medication reduction), with stable disease parameters over time. Combined and Standalone subgroups had similar outcomes.
Collapse
|
21
|
Zhang S, Hu C, Cheng H, Gu J, Samuel K, Lin H, Deng Y, Xie Y, Hu J, Le R, Xu S, Tham CC, Liang Y. Efficacy of bleb-independent penetrating canaloplasty in primary angle-closure glaucoma: one-year results. Acta Ophthalmol 2022; 100:e213-e220. [PMID: 33880864 DOI: 10.1111/aos.14869] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 03/02/2021] [Accepted: 03/16/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE To report the efficacy and safety of bleb-independent penetrating canaloplasty in the management of primary angle-closure glaucoma (PACG). METHODS This single-centre prospective interventional case series enrolled 57 eyes from 53 PACG patients with medically uncontrolled intraocular pressure (IOP) and peripheral anterior synechiae of over 270°. Penetrating canaloplasty, mainly consisted of tensioning suture-aided Schlemm's canal dilation and a trabeculectomy, was performed to create a direct communication between the anterior chamber and the Schlemm's canal. Postoperative IOP, number of glaucoma medications and procedure-related complications were evaluated. Rate of success was defined as IOP ≤ 21, ≤18 and ≤15 mmHg, and a ≥30% IOP reduction without (complete) or with/without (qualified) IOP-lowering medications. RESULTS A total of 45 eyes had 360° catheterization successfully completed. The mean preoperative IOP was 33.9 ± 11.7 mmHg (range, 13-59.6 mmHg), on 3.2 ± 0.8 glaucoma medications (range 2-5), which was decreased to 15.4 ± 3.7 mmHg (range, 8.6-22.5) and 0.2 ± 0.6 (range, 0-3) medications at 6 months and 14.8 ± 3.5 mmHg (range, 9-24) and 0.1 ± 0.3 (range, 0-1) medications at 12 months postoperatively. Complete success at 12 months were achieved in 78.9% (95% CI: 0.65-0.93), 71.1% (0.56-0.86) and 50.0% (0.33-0.67) eyes at IOP ≤ 21, ≤18 and ≤15 mmHg, respectively. Transient IOP elevation (>30 mmHg, 26.7%) and hyphema (11.1%) were the most common early surgical complications. CONCLUSION Penetrating canaloplasty in PACG appeared to have good efficacy and safety profiles in this pilot study. Further studies are justified.
Collapse
Affiliation(s)
- Shaodan Zhang
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
- The National Clinical Research Center for Ocular Diseases of China Glaucoma Research Institute of Wenzhou Medical University Wenzhou China
| | - Cheng Hu
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
| | - Huanhuan Cheng
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
| | - Juan Gu
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
| | - Kwizera Samuel
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
| | - Haishuang Lin
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
- The National Clinical Research Center for Ocular Diseases of China Glaucoma Research Institute of Wenzhou Medical University Wenzhou China
| | - Yuxuan Deng
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
| | - Yanqian Xie
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
- The National Clinical Research Center for Ocular Diseases of China Glaucoma Research Institute of Wenzhou Medical University Wenzhou China
| | - Jingjing Hu
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
| | - Rongrong Le
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
- The National Clinical Research Center for Ocular Diseases of China Glaucoma Research Institute of Wenzhou Medical University Wenzhou China
| | - Shuxia Xu
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
- The National Clinical Research Center for Ocular Diseases of China Glaucoma Research Institute of Wenzhou Medical University Wenzhou China
| | - Clement C. Tham
- Department of Ophthalmology and Visual Sciences The Chinese University of Hong Kong Hong Kong SAR China
| | - Yuanbo Liang
- The Eye Hospital of Wenzhou Medical University Glaucoma Research Institute of Wenzhou Medical University Zhejiang China
- The National Clinical Research Center for Ocular Diseases of China Glaucoma Research Institute of Wenzhou Medical University Wenzhou China
| |
Collapse
|
22
|
Salimi A, Watt H, Harasymowycz P. Long-term outcomes of two first-generation trabecular micro-bypass stents (iStent) with phacoemulsification in primary open-angle glaucoma: eight-year results. EYE AND VISION 2021; 8:43. [PMID: 34782017 PMCID: PMC8594216 DOI: 10.1186/s40662-021-00263-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 10/11/2021] [Indexed: 02/06/2023]
Abstract
Background The short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up. Methods This longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery. Eight-year efficacy outcomes included mean intraocular pressure (IOP) and medications, as well as surgical success. Eight-year safety outcomes included best-corrected visual acuity (BCVA), visual field mean deviation (VF-MD), cup-to-disc ratio (CDR), retinal nerve fiber layer (RNFL) thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, and adverse events. Results A total of 62 eyes with primary open-angle glaucoma (POAG) were included. At 8 years postoperative, IOP reduced by 26% from 19.2 ± 3.9 mmHg preoperatively to 14.2 ± 2.4 mmHg (P < 0.001), 91.1% of eyes achieved IOP ≤ 18 mmHg (vs. 51.6% preoperatively), 69.6% of eyes achieved IOP ≤ 15 mmHg (vs. 14.5% preoperatively), and 25% of eyes achieved IOP ≤ 12 mmHg (vs. 1.6% preoperatively). Medication use decreased by 17.9% from 2.8 ± 1.1 preoperatively to 2.3 ± 1.2 (P = 0.018). Surgical success was 90%, as six eyes underwent subsequent glaucoma surgeries. Safety measures of BCVA, CDR, RNFL thickness and GC-IPL thickness remained stable through 8 years postoperative. VF-MD remained stable until postoperative year 5 and subsequently progressed according to the natural history of glaucomatous disease. Conclusions Implantation of two iStents with concomitant cataract surgery is an effective and safe treatment option for surgery-naïve POAG eyes, evidenced by significant IOP and medication reductions, reasonable surgical success, and favorable safety outcomes, throughout the 8-year follow-up. Our data additionally supports the efficacy of this combined procedure in stabilizing or slowing disease progression. Supplementary Information The online version contains supplementary material available at 10.1186/s40662-021-00263-1.
Collapse
Affiliation(s)
- Ali Salimi
- Department of Ophthalmology, Faculty of Medicine, McGill University, Montreal, QC, Canada.,Montreal Glaucoma Institute, Montreal, QC, Canada
| | - Harrison Watt
- Faculty of Medicine, McGill University, Montreal, QC, Canada
| | - Paul Harasymowycz
- Montreal Glaucoma Institute, Montreal, QC, Canada. .,Department of Ophthalmology, University of Montreal, 4135 de Rouen, Montreal, QC, H1V1G5, Canada.
| |
Collapse
|
23
|
Ang BCH, Tecson ICRO, Hu JYW, Kan JTC, Yip LWL. 12-Month Outcomes of Combined Phacoemulsification and iStent Inject in Asian Eyes with Normal Tension Glaucoma: A Single-Centre Experience. Int Ophthalmol 2021; 42:611-620. [PMID: 34652545 DOI: 10.1007/s10792-021-02033-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Accepted: 09/22/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate efficacy and safety of the iStent inject combined with phacoemulsification in Asian eyes with normal-tension glaucoma (NTG) up to 12 months after surgery. STUDY DESIGN Retrospective case series. METHODS Retrospective case series of eyes undergoing surgery from April 2017 to August 2019. Outcome measures included intraocular pressure (IOP), number of topical glaucoma medications and adverse outcomes. Data were retrieved from the post-operative day 1 (POD1), week 1 (POW1), month 1 (POM1), month 3 (POM3), month 6 (POM6) and month 12 (POM12) timepoints. Data were analysed at each timepoint for eyes with available clinical data at that visit. Subgroup analysis was performed for a consistent cohort which included only eyes with data at all six follow-up timepoints. RESULTS Data from 91 eyes in the collective subject group was analysed. Majority of subjects were male (53, 58.2%) and Chinese (79, 86.8%). Mean age was 73.2 ± 7.2 years. Pre-operatively, mean IOP was 14.3 ± 3.0 mmHg and mean number of medications was 1.5 ± 0.8. Significant IOP reduction was observed at all timepoints except POW1 and POM12. The number of medications was reduced at all timepoints (p < 0.001). By POM12, there was reduction of 1.2 ± 1.0 medications (p < 0.001). Both the collective and consistent cohorts demonstrated a trend towards decreasing surgical efficacy with time, in IOP reduction and decrease in medications. None of the eyes experienced sight-threatening complications. CONCLUSIONS Asian eyes with NTG undergoing combined phacoemulsification and iStent inject surgery demonstrated significant and sustained reduction in number of glaucoma medications up to 12 months post-operatively.
Collapse
Affiliation(s)
- Bryan C H Ang
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore.
- Department of Ophthalmology, Woodlands Health Campus, National Healthcare Group Eye Institute, Singapore, Singapore.
| | | | - Jeremy Y W Hu
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore
| | - John T C Kan
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore
| | - Leonard W L Yip
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore
| |
Collapse
|
24
|
Konopińska J, Saeed E, Lisowski Ł, Gołaszewska K, Kraśnicki P, Dmuchowska DA, Obuchowska I. Evaluation of the Effect of the First Generation iStent on Corneal Endothelial Cell Loss-A Match Case-Control Study. J Clin Med 2021; 10:jcm10194410. [PMID: 34640426 PMCID: PMC8509432 DOI: 10.3390/jcm10194410] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 09/16/2021] [Accepted: 09/24/2021] [Indexed: 12/31/2022] Open
Abstract
Glaucoma is the leading cause of irreversible blindness worldwide. The only proven factor in slowing the progression of glaucomatous neuropathy is lower intraocular pressure (IOP), which can be achieved with pharmacology, laser therapy, or surgery. However, these treatments are associated with various adverse effects, including corneal endothelial cell loss (CECL). In recent years, several novel surgeries for reducing the IOP, collectively referred to as minimally invasive glaucoma surgery (MIGS), have been developed, one of which is the iStent. However, the long-term effects of such surgeries remain unknown. We compared a group of patients with open-angle glaucoma and cataract who underwent phacoemulsification alone with a group of patients with similar demographic and clinical characteristics who underwent simultaneous phacoemulsification and iStent implantation. Overall, 26 eyes of 22 subjects who underwent a combined phacoemulsification-iStent procedure and 26 eyes of 24 subjects who underwent cataract surgery were included. Before surgery, endothelial cells accounted to 2228.65 ± 474.99 in iStent group and 2253.96 ± 404.76 in the control group (p = 0.836). After surgery, their number declined to 1389.77 ± 433.26 and 1475.31 ± 556.45, respectively (p = 0.509). There was no statistically significant difference in CECL between the two groups 18–24 months after surgery, despite increased manipulation in the anterior chamber and the presence of an implant in the trabecular meshwork in those with an iStent implant. Thus, iStent bypass implantation is a safe treatment in terms of CECL for mild-to-moderate open-angle glaucoma.
Collapse
|
25
|
Three-Year Outcomes of Second-generation Trabecular Micro-bypass Stents (iStent inject) With Phacoemulsification in Various Glaucoma Subtypes and Severities. J Glaucoma 2021; 30:266-275. [PMID: 33105306 DOI: 10.1097/ijg.0000000000001716] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 10/04/2020] [Indexed: 12/21/2022]
Abstract
PRECIS This longitudinal case series provides valuable long-term data on the safety and efficacy of iStent inject with concomitant cataract surgery. Patients experienced significant and durable reductions in both intraocular pressure (IOP) and medication burden through 3 years postoperative. PURPOSE The purpose of this study was to examine the 3-year effectiveness and safety of iStent inject second-generation trabecular micro-bypass stent implantation with concomitant phacoemulsification cataract surgery in eyes with various glaucoma subtypes and severities. METHODS This was a single-center consecutive case series. Three-year outcomes included mean IOP and medications, the proportions of eyes with IOP ≤18, ≤15, and ≤12 mm Hg, and success (absence of secondary glaucoma interventions). Safety included best-corrected visual acuity (BCVA), cup-to-disc ratio, visual field (VF) mean deviation, retinal nerve fiber layer (RNFL), and ganglion cell-inner plexiform layer (GCIPL) thickness, and adverse events. RESULTS A total of 124 eyes with different glaucoma subtypes and severities were included. At 3 years postoperative, mean IOP reduced from 16.90±3.85 mm Hg preoperatively to 13.17±2.83 mm Hg (22% reduction, P<0.001) and mean medication burden decreased from 2.38±1.29 medications preoperatively to 1.16±1.22 medications (51% reduction, P<0.001). At 3 years, 96% of eyes achieved IOP ≤18 mm Hg (vs. 69% preoperatively), 80% of eyes achieved IOP ≤15 mm Hg (vs. 40% preoperatively), and 42% of eyes achieved IOP ≤12 mm Hg (vs. 7% preoperatively) with 76% of eyes eliminating ≥1 medication and 37% of eyes eliminating ≥2 medications versus preoperative medication burden. The 3-year cumulative survival rate was 74%. Postphacoemulsification BCVA improvement was preserved, and cup-to-disc ratio, VF mean deviation, and RNFL and GCIPL thickness remained stable. A favorable safety profile included no intraoperative complications and few, transient, postoperative adverse events. CONCLUSION Significant and sustained IOP and medication reductions were achieved through 3 years after iStent inject implantation with cataract surgery in a real-world clinical population with mild-to-severe glaucoma, along with favorable safety including stable BCVA, VF, and RNFL and GCIPL thickness.
Collapse
|
26
|
Shalaby WS, Lam SS, Arbabi A, Myers JS, Moster MR, Kolomeyer NN, Razeghinejad R, Shukla AG, Hussein TR, Eid TM, Shalaby SM, Lee D. iStent versus iStent inject implantation combined with phacoemulsification in open angle glaucoma. Indian J Ophthalmol 2021; 69:2488-2495. [PMID: 34427250 PMCID: PMC8544096 DOI: 10.4103/ijo.ijo_308_21] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
Purpose To compare the outcomes of iStent vs. iStent inject implantation combined with phacoemulsification. Methods This single center retrospective comparative case series included subjects with open angle glaucoma who underwent iStent or iStent inject implantation combined with phacoemulsification with ≥1 year follow-up. The main outcome measures were in-group and between-group changes in intraocular pressure (IOP) and medication number, proportion of eyes that achieved IOP ≤15 mmHg, and surgical success defined as 20% IOP reduction from baseline at 6/12 months. Univariate/multivariate regression analyses were done to identify predictors of surgical failure. Results One hundred ninety-seven eyes of 148 patients were included (122 iStent, 75 iStent inject). Both groups achieved significant IOP and medication reduction at months 6/12 (P < 0.05). At month 6, IOP was significantly lower in iStent inject vs. iStent eyes (P = 0.003), but the difference was insignificant by month 12 (P = 0.172). Medication number was comparable in both groups at months 6/12 (P > 0.05). More iStent inject eyes achieved IOP ≤15 mmHg at month 6 (P = 0.003) and 12 (P = 0.047). Surgical success was comparable in both groups at months 6/12 (P > 0.05). Kaplan-Meier survival analysis showed similar cumulative rate of surgical failure at year-1 in both groups (P = 0.644). The multivariate model identified older age (P = 0.017) and lower baseline IOP (P = 0.002) as the strongest predictors of surgical failure. Conclusion Compared to iStent, iStent inject achieved lower IOP at month 6 and higher proportion of eyes achieved IOP ≤15 mmHg at month 6/12. However, surgical success was similar in both groups. Predictors of surgical failure were older age and lower baseline IOP rather than the stent type.
Collapse
Affiliation(s)
- Wesam Shamseldin Shalaby
- Glaucoma Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA; Tanta Medical School, Tanta University, Tanta, Gharbia, Egypt
| | - Sophia S Lam
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Amirmohsen Arbabi
- Glaucoma Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Jonathan S Myers
- Glaucoma Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Marlene R Moster
- Glaucoma Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Natasha N Kolomeyer
- Glaucoma Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Reza Razeghinejad
- Glaucoma Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Aakriti Garg Shukla
- Glaucoma Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Tarek R Hussein
- Tanta Medical School, Tanta University, Tanta, Gharbia, Egypt
| | - Tarek M Eid
- Tanta Medical School, Tanta University, Tanta, Gharbia, Egypt
| | - Said M Shalaby
- Tanta Medical School, Tanta University, Tanta, Gharbia, Egypt
| | - Daniel Lee
- Glaucoma Research Center, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA
| |
Collapse
|
27
|
iStent inject: comprehensive review. J Cataract Refract Surg 2021; 47:385-399. [PMID: 32842078 DOI: 10.1097/j.jcrs.0000000000000325] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 06/22/2020] [Indexed: 11/26/2022]
Abstract
Microinvasive glaucoma surgeries (MIGSs) are new surgical procedures for treatment of glaucoma. They aim to safely and effectively reduce intraocular pressure (IOP) with minimal trauma to the eye and less complications. The first-generation iStent is the first approved ab interno MIGS implant for management of open-angle glaucoma. It works by allowing aqueous humor to drain directly from the anterior chamber into Schlemm canal bypassing the trabecular meshwork, the major site of outflow resistance. The second-generation iStent inject is the smallest available trabecular device that occupies less than 0.5 mm. It is designed to facilitate the surgical technique and allow simultaneous implantation of 2 stents, aiming for more IOP reduction. This review examines publications about the iStent inject, focusing on the device's efficacy, safety, and comparison with the first generation iStent. Both devices were found to be a safe and effective tool in management of open-angle glaucoma.
Collapse
|
28
|
Ab externo device for the treatment of glaucoma: direct flow from the anterior chamber to the ocular surface. J Cataract Refract Surg 2021; 46:941-943. [PMID: 32271273 DOI: 10.1097/j.jcrs.0000000000000202] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
A new microinvasive glaucoma surgery device, the Beacon Aqueous Microshunt (BAM), drains aqueous humor directly from the anterior chamber to the surface of the eye vs draining to enclosed spaces within the eye, where outflow resistance, including the episcleral venous pressure, might limit drainage effectiveness. The BAM has a 0.030 mm × 0.048 mm channel and provides a fixed resistance. For implantation, a 1.40 mm wide transcorneal incision into the anterior chamber was created with a posterolimbal outer placement under topical anesthesia. The surgery was easy to execute and had a flat learning curve. Preliminary and early experience have shown success with lowering intraocular pressure immediately postoperatively. In conclusion, the BAM offers a promising minimally invasive surgical procedure.
Collapse
|
29
|
Abstract
Micro- or minimally invasive glaucoma surgeries (MIGS) have been the latest addition to the glaucoma surgical treatment paradigm. This term refers not to a single surgery, but rather to a group of distinct procedures and devices that aim to decrease intraocular pressure. Broadly, MIGS can be categorized into surgeries that increase the trabecular outflow [Trabectome, iStent (first and second generations), Hydrus microstent, Kahook Dual Blade and gonioscopy-assisted transluminal trabeculotomy], surgeries that increase suprachoroidal outflow (Cypass microstent and iStent Supra), and conjunctival bleb-forming procedures (Xen gel stent and InnFocus microshunt). Compared to traditional glaucoma surgeries, such as trabeculectomy and glaucoma drainage device implantation (Ahmed, Baerveldt, and Molteno valves), MIGS are touted to have less severe complications and shorter surgical time. MIGS represent an evolving field, and the efficacy and complications of each procedure should be considered independently, giving more importance to high-quality and longer-term studies.
Collapse
Affiliation(s)
- David J Mathew
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario M5T 2S8, Canada;
| | - Yvonne M Buys
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario M5T 2S8, Canada;
| |
Collapse
|
30
|
Reoperation for complications within 90 days of minimally invasive glaucoma surgery. J Cataract Refract Surg 2021; 47:886-891. [PMID: 33315736 DOI: 10.1097/j.jcrs.0000000000000545] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 12/01/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVE To describe reoperations that occurred within 90 days of minimally invasive glaucoma surgery (MIGS) at a single institution over a 30-month period. SETTING Tertiary care hospital. DESIGN Retrospective case series. METHODS Charts of adult patients who underwent trabecular microbypass stents, gel microstents, and goniotomy procedures (including gonioscopy-assisted transluminal trabeculotomy) from October 1, 2017, to March 15, 2020, at Wills Eye Hospital were examined. Outcome measures were unanticipated reoperations within the first 90 days after MIGS procedures and the complications that led to these reoperations. RESULTS A total of 448 MIGS procedures were performed on 436 eyes of 348 patients over a 30-month period by 6 glaucoma surgeons. Of these, 206 (46.0%) were trabecular microbypass stents (198 iStent/iStent inject and 8 Hydrus), 152 (33.9%) were gel microstents, and 90 (20.1%) were goniotomy procedures. Combined phacoemulsification took place in 256 eyes (58.7%). Reoperation within 90 days took place in 23 (5.3%) of 436 eyes, including 16 (10.5%) of 152 eyes in the gel microstent group, 4 (2.0%) of 198 eyes in iStent/iStent inject group, and 3 (3.3%) of 90 eyes in the goniotomy group. Indications for reoperation were elevated intraocular pressure (IOP) in 16 (69.6%) of 23 eyes, gel microstent tip exposure with wound leakage in 3 (13.0%) of 23 eyes, and early gel microstent encapsulation without elevated IOP in 1 (4.3%) of 23 eyes. Two (8.7%) of 23 eyes required reoperation for intraocular lens complications, whereas 1 (4.3%) of 23 eyes had elevated IOP and aphakia requiring reoperation. CONCLUSIONS The rate of reoperation within the first 90 days after MIGS was low. Elevated IOP and complications associated with gel microstents were the main indications for reoperation.
Collapse
|
31
|
Abstract
PURPOSE Interest in micro-invasive glaucoma surgery (MIGS) has exploded over the last 8 years with an increase in MIGS procedures of at least 400% in the United States, according to Medicare data. MIGS is an umbrella term that can cover many different types of surgeries. This review focuses on peer-reviewed evidence for Trabectome®, iStent inject®, Kahook Dual Blade®, XEN® Gel Stent, and Hydrus®. METHODS We present key recent studies evaluating the efficacy and safety of MIGS in various types of glaucoma patients with different stages of disease. CONCLUSION We conclude that MIGS is generally safe and efficacious, although only some MIGS have been studied through randomized clinical trials. When comparing and contrasting the different MIGS procedures, large prospective studies are not yet the norm. High-quality large prospective studies involving MIGS will be an important next step as ophthalmologists decide how to incorporate MIGS into their surgical armamentarium.
Collapse
Affiliation(s)
- Faith A Birnbaum
- Department of Ophthalmology, Glaucoma Service, Massachusetts Eye and Ear Infirmary, Boston, MA United States
| | - Cameron Neeson
- Department of Ophthalmology, Glaucoma Service, Massachusetts Eye and Ear Infirmary, Boston, MA United States
| | - David Solá-Del Valle
- Department of Ophthalmology, Glaucoma Service, Massachusetts Eye and Ear Infirmary, Boston, MA United States
| |
Collapse
|
32
|
Guemes-Villahoz N, Garcia-Feijoo J, Martinez-de-la-Casa JM, Torres-Imaz R, Donate-López J. Trabecular microbypass stent to treat ocular hypertension after intravitreal injection of a dexamethasone implant. J Fr Ophtalmol 2021; 44:e591-e594. [PMID: 34281762 DOI: 10.1016/j.jfo.2021.01.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 01/14/2021] [Accepted: 01/14/2021] [Indexed: 10/20/2022]
Affiliation(s)
- N Guemes-Villahoz
- Ophthalmology Department, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain.
| | - J Garcia-Feijoo
- Ophthalmology Department, Hospital Clínico San Carlos, Departamento de Inmunología, Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Oftared, Madrid, Spain
| | - J M Martinez-de-la-Casa
- Ophthalmology Department, Hospital Clínico San Carlos, Departamento de Inmunología, Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Oftared, Madrid, Spain
| | - R Torres-Imaz
- Ophthalmology Department, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - J Donate-López
- Ophthalmology Department, Hospital Clínico San Carlos, Departamento de Inmunología, Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Oftared, Madrid, Spain
| |
Collapse
|
33
|
Teus MA, Belda JI, Lavín C, GarcÃa-Feijoà J, Falvey H, Buseghin G, Soler M, Appierto M. Cost-effectiveness analysis of iStent Inject® implantation during cataract surgery compared to cataract surgery alone for mild to moderate open-angle glaucoma patients in Spain. EXPERT REVIEW OF OPHTHALMOLOGY 2021. [DOI: 10.1080/17469899.2021.1939685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Miguel A Teus
- Ophtalmology Department, Hospital Universitario Príncipe De Asturias, University of Alcalá, Madrid, Spain
| | - Jose I Belda
- Ophthalmology Department, Hospital Universitario Torrevieja, Alicante, Spain
| | - Cosme Lavín
- Ophthalmology Department, Hospital Universitario La Paz, Madrid, Spain
| | - Julián GarcÃa-FeijoÃ
- Ophthalmology Unit, Hospital Clínico San Carlos, Instituto De Investigación Sanitaria Del Hospital Clínico San Carlos (Idissc), OFTARED, Madrid, Spain
| | - H Falvey
- Health Economics and Market Access Department, Glaukos, San Clemente, California, United States
| | - Giorgio Buseghin
- Health Economics and Market Access Department, Glaukos, San Clemente, California, United States
| | - María Soler
- Health Economics Department, Outcomes’10 S.L.U, Castellón De La Plana, Spain
| | - Marilena Appierto
- Health Economics Department, Outcomes’10 S.L.U, Castellón De La Plana, Spain
| |
Collapse
|
34
|
Pahlitzsch M, Davids AM, Winterhalter S, Zorn M, Reitemeyer E, Klamann MKJ, Torun N, Bertelmann E, Maier AK. Selective Laser Trabeculoplasty Versus MIGS: Forgotten Art or First-Step Procedure in Selected Patients with Open-Angle Glaucoma. Ophthalmol Ther 2021; 10:509-524. [PMID: 33963524 PMCID: PMC8319229 DOI: 10.1007/s40123-021-00347-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 04/24/2021] [Indexed: 01/04/2023] Open
Abstract
Introduction To evaluate the long-term effect on intraocular pressure (IOP) and glaucoma medication of selective laser trabeculoplasty (SLT) compared to minimally invasive glaucoma surgery (MIGS) in primary open-angle glaucoma (POAG) and its potential in clinical practice. Methods A total of 342 consecutive patients (stand-alone procedures) were included. One hundred and five patients underwent SLT treatment (360° SLT, 95–105 spots, Trabeculas SLT ARCLaser, Nürnberg, DE), 107 patients had an ab interno-derived trabeculotomy (Trabectome®, NeoMedix, Tustin, USA), and 130 patients received iStent inject® implantation (2 implants-Glaukos, CA, USA). IOP and glaucoma therapy were evaluated preoperatively, 1 day, 6 weeks, 3 months, 6 months, and 1, 2, and 3 years postoperatively. Statistical analysis was performed using a regression model and propensity matching score (reduced cohort number) using SPSS v20.0. Kaplan–Meier analysis was included using the following six criteria: criterion A (IOP ≤ 21 mmHg with or without medication, qualified success), criterion B (IOP ≤ 18 mmHg with or without medication, qualified success), criterion C (IOP ≤ 21 mmHg without medication, complete success), criterion D (IOP ≤ 18 mmHg without medication, complete success), criterion E (IOP ≤ 21 mmHg and IOP reduction > 20% after therapy), and criterion F (IOP ≤ 18 mmHg and IOP reduction > 20% after therapy). Results In the matched cohort, the SLT cohort showed an IOP reduction of 31.2% from 19.9 ± 2.3 to 13.7 ± 2.7 mmHg (p < 0.001) 3 years postoperatively; in Trabectome® IOP decreased by 31.4% from 20.5 ± 1.3 to 13.8 ± 2.0 mmHg (p < 0.001) and in iStent inject® by 29.9% from 19.5 ± 2.0 to 13.8 ± 2.7 mmHg (p < 0.001). Trabectome® and iStent inject® could not demonstrate a significant reduction in glaucoma therapy (Trabectome®p = 0.138, iStent inject®p = 0.612); a significant drop was noted in SLT (2.2 ± 1.2 to 1.7 ± 1.2, p = 0.046). SLT and MIGS achieved good to moderate survival rates using criterion A (93.3% SLT, 79.7% Trabectome®, 77.6% iStent inject®) and criterion B (74.5% SLT, 48.0% Trabectome®, 56.2% iStent inject®). As expected, low survival rates were obtained with non-filtering procedures: criterion C 11.1% in SLT, 6.5% in Trabectome®, 7.0% in iStent inject® and criterion D 3.0% in SLT, 4.3% in Trabectome®, 3.7% in iStent inject® in 3-year follow-up. Conclusion The SLT is a low-complication and effective method for reducing pressure in mild to moderate POAG. SLT is suitable as an initial procedure when setting up a step scheme; MIGS is the treatment of choice as a follow-up for mild to moderate forms of glaucoma and accepted topical therapy. Ethic approval had been given by the Ethikkommission Charité – Universitätsmedizin Berlin, EA4/047/20—retrospectively registered. Supplementary Information The online version contains supplementary material available at 10.1007/s40123-021-00347-0.
Collapse
Affiliation(s)
- Milena Pahlitzsch
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - Anja-Maria Davids
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Sibylle Winterhalter
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Malte Zorn
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Emanuel Reitemeyer
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Matthias K J Klamann
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Necip Torun
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Eckart Bertelmann
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Anna-Karina Maier
- Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Berlin Institute of Health, Humboldt-Universität Zu Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| |
Collapse
|
35
|
Hu Yw J, Ang Ch B, Tecson IOC, Kan Tsia-Chuen J, Yip Wl L. Combined phacoemulsification and iStent inject implantation in Asian eyes. Eur J Ophthalmol 2021; 32:288-295. [PMID: 33745350 DOI: 10.1177/11206721211000641] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of the iStent inject device combined with phacoemulsification in Asian eyes with primary open angle glaucoma. METHODS A retrospective study of combined phacoemulsification and iStent inject surgeries performed in a single institution from July 2017 to August 2019 on patients with co-existing cataracts and primary open angle glaucoma (POAG). Outcome measures included best-corrected visual acuity, intraocular pressure (IOP), number of glaucoma eyedrop medications, and surgical complications. RESULTS A total of 95 eyes were included. Majority of subjects were male (59, 62.1%) and Chinese (83, 87.4%). Mean age was 74.7 ± 8.7 years. Pre-operatively, mean IOP was 16.2 ± 4.3 mmHg and number of medications was 1.9 ± 0.9. Significant post-operative reduction in mean IOP was observed at all timepoints - post-operative month (POM)1: 3.0 ± 5.6 mmHg reduction (n = 95, p < 0.05); POM3: 1.6 ± 3.8 mmHg (n = 66, p < 0.05); POM6: 1.8 ± 4.7 mmHg (n = 55, p < 0.05); POM12: 1.3 ± 4.2 mmHg (n = 48) (p < 0.05). The number of glaucoma medications was also reduced from a mean of 1.9 ± 0.8 to 0.6 ± 1.0 at POM12 (p < 0.05). Intraoperatively, one case of malignant glaucoma occurred. Post operatively, implant obstruction by iris was observed in two eyes post-operatively requiring iridoplasty. One case of cystoid macular edema and one case of drop in visual acuity due to glaucoma progression was/were also observed. CONCLUSION Asian eyes undergoing combined phacoemulsification and iStent inject surgery demonstrate a significant and sustained reduction in both IOP and number of glaucoma medications. Overall, there is a good safety profile for iStent inject.
Collapse
Affiliation(s)
- Jeremy Hu Yw
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore
| | - Bryan Ang Ch
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore
| | - Ivan O'Neill C Tecson
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore.,Cardinal Santos Medical Centre, San Juan, Metro Manila, Philippines
| | - John Kan Tsia-Chuen
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore
| | - Leonard Yip Wl
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore.,Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore
| |
Collapse
|
36
|
Abstract
BACKGROUND The main goals of glaucoma treatment are to preserve the visual function and maintain as high a quality of life as possible at a cost acceptable to society. Therefore, it is crucial to carefully observe each individual patient in order to determine an individual and personalized treatment approach. MATERIAL AND METHODS This article summarizes the advantages and disadvantages of medicinal glaucoma treatment as well as traditional methods of glaucoma surgery, based on the current state of knowledge. The article explains the various mechanisms of action of new minimally invasive procedures, introduces the methods mostly commonly used in Germany and gives recommendations for preoperative care and postoperative follow-up. RESULTS/CONCLUSION In addition to the plethora of medicinal glaucoma treatments and classical surgical procedures, new minimally invasive treatment alternatives have become available in the past few years. The latter are an option for an earlier surgical intervention, especially in naïve or previously treated patients who appear to be unsuitable for medicinal treatment.
Collapse
Affiliation(s)
- Esther M Hoffmann
- Augenklinik und Poliklinik, Universitätsmedizin Mainz, Mainz, Deutschland.
| | - Fritz Hengerer
- Bürgerhospital Frankfurt a. M., Frankfurt a. M., Deutschland
| | - Karsten Klabe
- Breyer - Kaymak - Klabe Augenchirurgie, Düsseldorf, Deutschland
| | - Marc Schargus
- Asklepios Augenklinik Nord-Heidberg Hamburg, Hamburg, Deutschland
- Universitäts-Augenklinik Düsseldorf, Düsseldorf, Deutschland
| | - Hagen Thieme
- Universitätsaugenklinik Magdeburg, Magdeburg, Deutschland
| | | |
Collapse
|
37
|
Standalone iStent Trabecular Micro-bypass Glaucoma Surgery: A Systematic Review and Meta-Analysis. J Glaucoma 2021; 30:606-620. [PMID: 33596009 DOI: 10.1097/ijg.0000000000001805] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 01/07/2021] [Indexed: 11/25/2022]
Abstract
PRECIS Standalone trabecular micro-bypass glaucoma surgery with the iStent devices is associated with clinically relevant reductions in intraocular pressure (IOP) sustained over a reasonably long-term while simultaneously reducing medication burden and a relatively favorable safety profile. PURPOSE While there is a relatively large body of evidence supporting the implantation of the iStent trabecular micro-bypass devices during phacoemulsification in patients with open-angle glaucoma (OAG), its efficacy as a standalone procedure has been less widely reported. The aims of this study were to systematically identify and quantitatively evaluate the efficacy of iStent devices (iStent and iStent inject) when performed independently of cataract surgery in patients with OAG. METHODS A systematic review of the literature was undertaken in August 2019 to identify studies of standalone trabecular micro-bypass glaucoma surgery with iStent devices in patients with OAG. All randomized trials were considered and nonrandomized studies that included at least 6 months of follow-up or more than 10 eyes. Key efficacy analyses included postoperative IOP and medication use, which were used to evaluate weighted mean differences from baseline, and the proportion of eyes free of ocular medication. Postoperative adverse events were descriptively summarized. RESULTS A total of 13 studies were identified including 4 randomized controlled trials and 9 nonrandomized or single-arm studies providing data for 778 eyes. In eyes implanted with iStent devices, a weighted mean IOP reduction of 31.1% was observed at 6 to 12 months. In studies reporting longer-term outcomes (36 to 48 mo or 60 mo), the weighted mean IOP reduction was 30.4% and 32.9%, respectively. The pooled weighted mean reduction in IOP from baseline across all studies at 6 to 12 months and 36 to 60 months poststent implantation was 7.01 mm Hg (95% confidence interval: 5.91, 8.11) and 6.59 mm Hg (95% confidence interval: 5.55, 7.63), respectively. Medication burden was reduced by ~1.0 medication at 6 to 18 months and 1.2 medications at 36 to 60 months. Adverse events reported in more than 5% of participants were progression of pre-existing cataract/cataract surgery and loss of best-corrected visual acuity but these rates were no different to those reported in comparator medical therapy study arms. CONCLUSIONS The results from these studies support the independent effect of the iStent trabecular bypass devices on IOP and medication burden over a duration of follow-up of up to 5 years.
Collapse
|
38
|
Recurrent, Delayed-Onset Hyphema Following iStent Inject Managed With Device Removal: A Case Report. J Glaucoma 2021; 30:e184-e186. [PMID: 33596013 DOI: 10.1097/ijg.0000000000001808] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 01/18/2021] [Indexed: 11/25/2022]
Abstract
Minimally invasive glaucoma surgeries have become increasingly popular in recent years, with the iStent Inject trabecular micro-bypass device (Glaukos, Laguna Hills, CA) being a well-tolerated treatment option for mild to moderate glaucoma, available for placement at the time of cataract surgery. While there have been reports of hyphema in the immediate postoperative period, there is little information available regarding etiology and management of delayed-onset, recurrent hyphema following iStent Inject placement. We present a case of recurrent hyphema occurring after iStent Inject placement and describe successful management with surgical removal of the device. Since we observed a reflux of heme originating from the site of stent placement into the anterior chamber intraoperatively when the intraocular pressure was lowered, we hypothesize that placement of the device into a collector channel allowed for influx of heme when the intraocular pressure dropped below episcleral venous pressure.
Collapse
|
39
|
Arnljots TS, Economou MA. Kahook Dual Blade Goniotomy vs iStent inject: Long-Term Results in Patients with Open-Angle Glaucoma. Clin Ophthalmol 2021; 15:541-550. [PMID: 33603332 PMCID: PMC7884935 DOI: 10.2147/opth.s284687] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 12/21/2020] [Indexed: 12/05/2022] Open
Abstract
Purpose Efficacy and safety evaluation of Kahook Dual Blade (KDB) goniotomy vs iStent inject implantation. Materials and Methods Retrospective study in patients that underwent goniotomy with KDB or iStent inject implantation, stand-alone or combined with cataract surgery. Main outcome parameters were intraocular pressure (IOP), number of glaucoma medications, proportion of eyes achieving >20% IOP reduction and number of eyes with postoperative IOP <19 mmHg at last follow-up. Results A total of 29 patients (30 eyes) were included in the iStent inject group and 30 patients (32 eyes) in the KDB group. Mean follow-ups were 20.9±6.5 (KDB-alone) to 29.5±7.6 (phaco-iStent inject) months. Pre- and post-operative IOPs were 22.2±5.8 mmHg and 15.9±4.3 mmHg (P=0.004) in the KDB-alone, 24.2±6.8 mmHg and 16.2±6.7 mmHg (P=0.001) in the phaco-KDB, 20.6±5.4 mmHg and 20.9±6.8 mmHg (P=0.598) in the iStent inject-alone as well as 20.9±5.5 mmHg and 15.6±3.4 mmHg (P=0.003) in the phaco-iStent inject subgroups. No major complications occurred. Conclusion All KDB and iStent subgroups except the stand-alone iStent inject subgroup showed a clinically significant IOP-lowering effect as a stand-alone procedure or combined with cataract surgery. Goniotomy with KDB in this setting seems to offer an advantageous IOP reduction compared to iStent inject.
Collapse
Affiliation(s)
| | - Mario A Economou
- Division of Ophthalmology and Vision, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Ophthalmology, Sophiahemmet Hospital, Stockholm, Sweden
| |
Collapse
|
40
|
Mercer R, Alaghband P. Critique of the Study, "Five-year Outcomes Prospective Study of Two First-Generation Trabecular Micro-Bypass Stents (Istent®) in Open-Angle Glaucoma" by Hady Saheb Et Al. Curr Eye Res 2021; 46:1073-1074. [PMID: 33302706 DOI: 10.1080/02713683.2020.1863429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
41
|
Silveira Seixas RC, Balbino M, Basile Neto A, de Alcantara Almeida Costa A, Jordão MLDS, Russ HHA. Mid-Term Evaluation of iStent Inject ® Trabecular Micro-Bypass Stent Implantation with or without Phacoemulsification: A Retrospective Study. Clin Ophthalmol 2020; 14:4403-4413. [PMID: 33364745 PMCID: PMC7751698 DOI: 10.2147/opth.s283587] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 11/13/2020] [Indexed: 11/23/2022] Open
Abstract
Introduction This study evaluated the 6-month performance and safety of micro-invasive glaucoma surgery (MIGS) with iStent inject either with or without cataract surgery. Material and Methods Longitudinal retrospective study of 86 surgeries in 49 patients with inadequately controlled open-angle glaucoma (OAG) or ocular hypertension who underwent iStent inject trabecular micro-bypass implantation either alone (isolated group) or combined with cataract surgery (combined group). The two primary outcomes included an intraocular pressure (IOP) drop of ≥20% versus preoperative values (adequate drop) and IOP maintenance between 6 and 18 mmHg (adequate Range). For both outcomes, we determined “complete” and “qualified” success if patients did not require or did require glaucoma medications, respectively, at the end of follow-up. Safety outcomes included best-corrected visual acuity, adverse events, and secondary surgeries. Results In the adequate drop analysis, 30.2% achieved “complete success,” and 37.2% achieved “qualified success.” For adequate range, 40.7% achieved “complete success” and 39.5% achieved “qualified success.” There was no difference in medication decrease (p=0.77) nor IOP reduction (p=0.46) between the isolated and combined groups. Safety was generally favorable and similar between groups, with mild transient adverse events that resulted in no sequelae. Discussion/Conclusion iStent inject implantation either with or without cataract surgery was able to safely decrease IOP and medication requirements through 6 months after surgery.
Collapse
Affiliation(s)
| | - Marcos Balbino
- HCloe Oftalmologia Especializada, Centro Universitário São Camilo, São Paulo, SP, Brazil
| | - Alberto Basile Neto
- Clínica Oftalmológica do Complexo Hospitalar Padre Bento de Guarulhos, Guarulhos, SP, Brazil
| | - Amanda de Alcantara Almeida Costa
- Clínica Oftalmológica do Complexo Hospitalar Padre Bento de Guarulhos, Guarulhos, Universidade Estadual de Campinas, Campinas, SP, Brazil
| | - Marcelo Lopes da Silva Jordão
- Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto Medical School, Universidade de São Paulo, Ribeirão Preto, Brazil
| | | |
Collapse
|
42
|
A Prospective Analysis of iStent Inject Microstent Implantation: Surgical Outcomes, Endothelial Cell Density, and Device Position at 12 Months. J Glaucoma 2020; 29:639-647. [PMID: 32433094 DOI: 10.1097/ijg.0000000000001546] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
PRECIS The surgical outcome of iStent inject devices is associated with device protrusion within the anterior chamber. Schlemm canal (SC) dilatation has a prognostic value. iStent inject devices do not move within the first year after implantation. INTRODUCTION The iStent inject is a device designed to be implanted ab-interno through the trabecular meshwork. The present study follows up on our preliminary report, using successive in vivo anterior segment optical coherence tomography (AS-OCT) imaging to analyze the associations between stent positioning, iridocorneal angle structures, and surgical outcomes. METHODS In total, 54 eyes of 42 patients (73.3±7.4 y) with cataract and mild-to-moderate open-angle glaucoma were examined in this prospective study. All patients underwent implantation of 2 iStent inject devices combined with phacoemulsification. Patients were followed up over a 12-month period. AS-OCT was performed after 3 and 12 months. Thirty unoperated fellow eyes served as control eyes. RESULTS Intraocular pressure (IOP) decreased from 16.5±4.2 mm Hg at baseline to 15.1±3.7 mm Hg at 12 months (-8.7%; P=0.004), while medications decreased from 1.8±1.0 to 0.5±0.9 (-72.2%; P<0.001). Unmedicated IOP≤18 mm Hg was achieved in 58.8% of operated eyes. No sight-threatening complications were reported. On AS-OCT, 44.9% of devices were buried within the trabeculum. Device position was unchanged between scans. Regression analysis elicited significant predictors: SC dilatation effect [risk ratio (RR)=0.230; P=0.003], greatest SC diameter (RR=0.991; P=0.049), extrusion of the most anterior device (RR=0.993; P=0.012), gonioscopically visible devices (RR=0.406; P=0.040), baseline treatments (RR=2.214; P=0.001), and baseline IOP (RR=0.184; P=0.006). Endothelial cell density decreased by 14.6% at 12 months (P<0.001). CONCLUSIONS This study demonstrates the IOP-lowering and medication-lowering potential of iStent inject surgery in primary open-angle and pseudoexfoliative glaucoma. It confirms that surgical outcomes are positively associated with device protrusion within the anterior chamber, and suggests SC dilatation effect as a favorable prognostic indicator. It shows that stents are stable in time, highlighting the importance of the initial implantation location.
Collapse
|
43
|
Maier AKB, Arani P, Pahlitzsch M, Davids AM, Pilger D, Klamann MKJ, Winterhalter S. Influence of Selective Laser Trabeculoplasty (SLT) on the iStent inject® outcomes. BMC Ophthalmol 2020; 20:457. [PMID: 33213403 PMCID: PMC7678109 DOI: 10.1186/s12886-020-01723-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 11/09/2020] [Indexed: 11/29/2022] Open
Abstract
Background To evaluate the influence of Selective Laser Trabeculoplasty (SLT) on iStent inject® outcomes in open-angle glaucoma (OAG). Methods In this retrospective comparative cohort outcome study, 66 patients who were treated with two iStent inject® devices were included. Patients were divided into two subgroups consisting of patients without SLT treatment prior to surgery and patients who had been treated previously with 360° SLT but without sufficient response. Outcome measures included intraocular pressure (IOP) and number of antiglaucoma medications after 6 weeks with three, six, 12, and 24 month follow-ups. Results Mean preoperative IOP decreased from 20.4 ± 5.3 mmHg to 14.8 ± 3.0 mmHg for patients without SLT treatment prior to surgery (p = 0.001) and from 19.2 ± 4.5 mmHg to 14.0 ± 1.6 mmHg for patients with insufficient response to 360° SLT treatment (p = 0.027) at 12 months after iStent inject® implantation. No significant difference was found between the two groups (p > 0.05). The number of antiglaucoma medications did not change in both groups (p > 0.05) and showed no significant difference between the two groups (p > 0.05). Conclusion Prior SLT treatment seems to have no negative influence on the IOP lowering-effect of iStent inject® implantation in patients with OAG. It is therefore an appropriate incremental procedure with no exclusion criterion for an iStent inject® implantation.
Collapse
Affiliation(s)
- Anna-Karina B Maier
- Department of Ophthalmology, Campus Virchow- Klinikum, Charité - University Medicine Berlin, corporate member of Freie Universität Berlin, Humboldt- Universität zu Berlin and Berlin Institute of Health, Berlin, Germany.
| | - Parisa Arani
- Department of Ophthalmology, Campus Virchow- Klinikum, Charité - University Medicine Berlin, corporate member of Freie Universität Berlin, Humboldt- Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Milena Pahlitzsch
- Department of Ophthalmology, Campus Virchow- Klinikum, Charité - University Medicine Berlin, corporate member of Freie Universität Berlin, Humboldt- Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Anja-Maria Davids
- Department of Ophthalmology, Campus Virchow- Klinikum, Charité - University Medicine Berlin, corporate member of Freie Universität Berlin, Humboldt- Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Daniel Pilger
- Department of Ophthalmology, Campus Virchow- Klinikum, Charité - University Medicine Berlin, corporate member of Freie Universität Berlin, Humboldt- Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Matthias K J Klamann
- Department of Ophthalmology, Campus Virchow- Klinikum, Charité - University Medicine Berlin, corporate member of Freie Universität Berlin, Humboldt- Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| | - Sibylle Winterhalter
- Department of Ophthalmology, Campus Virchow- Klinikum, Charité - University Medicine Berlin, corporate member of Freie Universität Berlin, Humboldt- Universität zu Berlin and Berlin Institute of Health, Berlin, Germany
| |
Collapse
|
44
|
Kasahara M, Shoji N. Effectiveness and limitations of minimally invasive glaucoma surgery targeting Schlemm's canal. Jpn J Ophthalmol 2020; 65:6-22. [PMID: 33150512 DOI: 10.1007/s10384-020-00781-w] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Accepted: 09/07/2020] [Indexed: 12/15/2022]
Abstract
Glaucoma surgery is performed to lower intraocular pressure (IOP); ideally, the IOP reduction is safely maintained for an extended period of time. Although trabeculectomy was considered the gold standard for glaucoma surgery for many years because of its effective IOP reduction, yet now it is considered unsafe because of serious complications. In recent years, minimally invasive glaucoma surgery (MIGS), which emphasizes safety and can be performed rapidly, has become widespread. Because MIGS does not involve conjunctival incisions, patients can undergo future trabeculectomy. If IOP reduction can be maintained safely, the number of anti-glaucoma drops can be reduced and visual function maintained, good outcomes for patients with glaucoma. Currently, many types of MIGS approved in Japan are reported to yield relatively good results, with targets of approximately 15-19 mmHg. However, the IOP-lowering effects of MIGS are limited. In procedures targeting Schlemm's canal, it is difficult to lower IOP beyond episcleral venous pressure. In some instances, a beneficial effect cannot be achieved if function is reduced beyond the collector channel. There are many unclear aspects regarding long-term outcomes following MIGS. Notably, investigation is ongoing to determine which patients are likely to benefit most from surgery. Based on previous reports, this review describes the characteristics and results of MIGS, approved in Japan, as well as underlying factors that affect the preoperative predictions and outcomes of the surgical procedure.
Collapse
Affiliation(s)
- Masayuki Kasahara
- Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan
| | - Nobuyuki Shoji
- Department of Ophthalmology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-ku, Sagamihara, Kanagawa, 252-0374, Japan.
| |
Collapse
|
45
|
Clement C, Howes F, Ioannidis AS, Shiu M, Manning D, Lusthaus J, Lim R, Skalicky SE, Goodwin T. Two-Year Multicenter Outcomes of iStent inject Trabecular Micro-Bypass Stents Combined with Phacoemulsification in Various Types of Glaucoma and Ocular Hypertension. Clin Ophthalmol 2020; 14:3507-3517. [PMID: 33149544 PMCID: PMC7604539 DOI: 10.2147/opth.s271646] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 10/15/2020] [Indexed: 12/11/2022] Open
Abstract
Purpose This multicenter study evaluated 2-year effectiveness and safety following implantation of two second-generation trabecular micro-bypass stents (iStent inject®) with phacoemulsification. Materials and Methods This was a retrospective study of iStent inject implantation with phacoemulsification by nine surgeons across Australia. Eyes had mild to advanced glaucoma (predominantly primary open-angle/POAG, appositional angle-closure/ACG, or normal-tension/NTG) or ocular hypertension (OHT), and cataract. Evaluations included intraocular pressure (IOP); medications; proportions of eyes with 0 or ≥2 medications, reduced/stable medications versus preoperative, and IOP ≤15 mmHg; visual acuity; cup-to-disc ratio (CDR); visual fields (VF); adverse events; and secondary surgery. Results A total of 340 eyes underwent surgery and had 24-month follow-up data. At 24 months, mean IOP decreased by 16% from 16.4±4.7 mmHg preoperatively to 13.7±3.1 mmHg (p<0.001), and 77% of eyes achieved IOP of ≤15 mmHg versus 49% preoperatively (p<0.001). Mean number of medications decreased by 67% to 0.49±0.95 versus 1.49±1.20 preoperatively (p<0.001), with 74% of eyes medication-free versus 25% preoperatively (p<0.001), and 14% of eyes on ≥2 medications versus 46% preoperatively (p<0.001). Medication burden was reduced or stable in 98% of eyes versus preoperative. Stratified analyses showed significant IOP and medication reductions across glaucoma subtypes (POAG, ACG, NTG, OHT): 13–22% for IOP (p<0.01 for all) and 62–100% for medication (p<0.001 for all). Favorable safety included few adverse events; stable CDR, VF, and visual acuity; and filtering surgery in only 8 eyes (2.4%) over 2 years. Conclusion This 340-eye multicenter dataset provides robust evidence of the safety and efficacy of iStent inject implantation with phacoemulsification, with significant and sustained IOP and medication reductions through 2 years. Results were similarly favorable across glaucoma subtypes (including POAG, ACG, NTG, OHT) and were attained across various glaucoma severities, clinical sites, and surgeons, highlighting the real-world versatility and utility of this treatment modality.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia.,Fairfield Eye Surgery, Fairfield, NSW, Australia.,Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia.,Eyehaus, Sydney, NSW, Australia
| | - Ridia Lim
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Hunter St. Eye Specialists, Parramatta, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
46
|
Nitta K, Yamada Y, Morokado S, Sugiyama K. iStent Trabecular Micro-Bypass Stent Implantation with Cataract Surgery in a Japanese Glaucoma Population. Clin Ophthalmol 2020; 14:3381-3391. [PMID: 33116389 PMCID: PMC7574908 DOI: 10.2147/opth.s274281] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 09/28/2020] [Indexed: 01/18/2023] Open
Abstract
Introduction This study assesses two-year efficacy and safety following implantation of a single trabecular micro-bypass stent (iStent®) with concomitant phacoemulsification cataract surgery in Japanese patients with open-angle glaucoma (OAG). Materials and Methods This retrospective, consecutive case series included eyes that underwent iStent implantation with phacoemulsification and were followed for 24 months postoperative. Efficacy and safety measures included intraocular pressure (IOP), number of glaucoma medications, adverse events, secondary surgeries, visual fields, and endothelial cell counts. Results Of 73 operated eyes, 53 eyes had 24 months of follow-up and are analyzed. Diagnoses included primary open-angle glaucoma (POAG, n=25), normal-tension glaucoma (NTG, n=16), and pseudoexfoliative glaucoma (PXG, n=12). At 24 months, mean IOP reduced by 18% to 13.6±3.0 mmHg versus 16.5±3.4 mmHg preoperatively (p<0.0001), and mean medication number reduced by 81% to 0.37±0.74 versus 1.96±0.98 preoperatively (p<0.0001). The percentage of medication-free eyes was 77% versus 0% preoperatively, and 81% of eyes had IOP ≤15 mmHg versus 42% preoperatively. Results were similarly favorable across glaucoma subtypes (POAG, NTG, PXG). Notably, mean IOP in NTG eyes decreased to 12.8±1.4 mmHg from 14.4±3.0 mmHg preoperatively (p=0.03), and medications decreased by 87% to 0.31±0.70 versus 2.38±0.72 preoperatively (p<0.0001). At 24 months, 81% of NTG eyes were medication-free (versus 0% preoperatively); 2 NTG eyes (13%) were on ≥2 medications (versus 100% preoperatively). Throughout the follow-up, visual fields and endothelial cell counts remained stable; 1 eye (1.9%) underwent filtration surgery. Discussion Favorable safety and significant IOP and mediation reductions were achieved through two years following iStent implantation with phacoemulsification in a Japanese population. These gains were achieved across all glaucoma subtypes (including POAG, NTG, PXG). Conclusion This real-world study supports the viability of iStent implantation to treat Japanese patients with glaucoma and shows that the benefits extend to those with NTG or PXG in addition to POAG.
Collapse
Affiliation(s)
- Koji Nitta
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Yutaro Yamada
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Satomi Morokado
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Kazuhisa Sugiyama
- Department of Ophthalmology, Kanazawa University, Kanazawa, Ishikawa Prefecture, Japan
| |
Collapse
|
47
|
Costagliola C, Sbordone M, Gandolfi S, Cesari L, Furneri G, Fea AM. Minimally Invasive Surgery in Mild-to-Moderate Glaucoma Patients in Italy: Is It Time to Change? Clin Ophthalmol 2020; 14:2639-2655. [PMID: 32982157 PMCID: PMC7500840 DOI: 10.2147/opth.s264839] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 08/04/2020] [Indexed: 12/11/2022] Open
Abstract
Medical therapy is the first treatment choice for most patients with glaucoma; however, in a relevant proportion of patients, intraocular pressure (IOP) reduction is achieved with multi-therapy and/or high therapeutic doses. Conventional surgery is the standard alternative to medical therapy when this is not effective or not tolerated. Recently, selective laser trabeculoplasty (SLT) has been advocated as first-line therapy, and "minimally invasive glaucoma surgery" (MIGS) has been developed as safer and less traumatic surgical intervention for patients with glaucoma. Schlemm's canal surgery has emerged as one of the approaches with the most favorable risk-benefit profile for glaucoma patients in need of cataract surgery. However, despite the promising results, use of MIGS in Italy has been extremely low. We aimed to investigate the reasons of the lower-than-expected use of Schlemm's canal-based MIGS devices in Italy, share our perspective on their potential place in therapy, and give practical suggestions to improve the management of glaucoma patients.
Collapse
Affiliation(s)
- Ciro Costagliola
- Department of Medicine & Health Sciences “V. Tiberio”, University of Molise, Campobasso, Italy
| | - Mario Sbordone
- Ophthalmology Unit, Santa Maria Delle Grazie Hospital, Pozzuoli, Naples, Italy
| | - Stefano Gandolfi
- Ophthalmology Unit, Department of Biological, Biotechnological and Translational Sciences, University of Parma, Parma, Italy
| | - Luca Cesari
- UOC Ophthalmology - Area 5, Ascoli Piceno, San Benedetto del Tronto, Italy
| | | | | |
Collapse
|
48
|
Visual outcomes of combined cataract surgery and minimally invasive glaucoma surgery. J Cataract Refract Surg 2020; 46:1422-1432. [PMID: 32657904 DOI: 10.1097/j.jcrs.0000000000000317] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Minimally invasive glaucoma surgery (MIGS) has become a reliable standard of care for the treatment of glaucoma when combined with cataract surgery. This review describes the MIGS procedures currently combined with and without cataract surgery with a focus on visual outcomes based on the literature and the experience of the ASCRS Glaucoma Clinical Committee.
Collapse
|
49
|
Second-Generation Trabecular Micro-Bypass (iStent inject) with Cataract Surgery in Eyes with Normal-Tension Glaucoma: One-Year Outcomes of a Multi-Centre Study. Ophthalmol Ther 2020; 9:585-596. [PMID: 32613589 PMCID: PMC7406634 DOI: 10.1007/s40123-020-00266-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Indexed: 02/08/2023] Open
Abstract
Purpose The efficacy and safety of the trabecular micro-bypass stents (iStent and iStent inject) have been well documented in various open-angle glaucoma subtypes. However, their outcomes remain understudied in normal-tension glaucoma (NTG). The present study aimed to assess the 1-year outcomes related to the implantation of two second-generation trabecular micro-bypass stents (iStent inject) concomitant with cataract surgery (CE-TMS), exclusively in eyes with NTG. Methods This multi-center, consecutive case series included eyes with cataract and normal-tension glaucoma that underwent CE-TMS to reduce intraocular pressure or glaucoma medication use. The 12-month efficacy measures included change in average intraocular pressure (IOP) and medication burden. Safety included change in best-corrected visual acuity, cup-to-disc ratio, visual field mean-deviation and retinal nerve fiber layer thickness. Intra- or postoperative adverse events were noted. Results A total of 62 eyes with mild-to-severe NTG and average preoperative IOP of 15.82 ± 2.94 mmHg on 1.50 ± 1.28 glaucoma medications were included. Postoperatively, IOP declined by 22% from 15.82 ± 2.94 mmHg to 12.32 ± 2.58 (p < 0.001), all eyes had IOP ≤ 18 mmHg (versus 74% preoperatively), and half had IOP ≤ 12 mmHg (versus 15% preoperatively). Medication burden decreased by 70% from 1.50 ± 1.28 to 0.45 ± 0.86 (p < 0.001), and 73% of the eyes were medication-free (versus 23% preoperatively). Safety was favorable, with no evidence of sight-threatening adverse events. Conclusion Implantation of iStent inject (two second-generation trabecular micro-bypass stents) combined with cataract surgery is efficacious in reducing IOP and medication burden with a favorable safety profile in eyes with mild-to-severe NTG.
Collapse
|
50
|
Use of iStent as a Standalone Operation in Patients with Open-Angle Glaucoma. J Ophthalmol 2020; 2020:8754730. [PMID: 32566270 PMCID: PMC7267876 DOI: 10.1155/2020/8754730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 05/03/2020] [Accepted: 05/12/2020] [Indexed: 12/04/2022] Open
Abstract
Purpose The iStent provides a direct pathway for aqueous outflow from the anterior chamber to Schlemm's canal in patients with open-angle glaucoma (OAG). We performed a meta-analysis to evaluate the effectiveness of iStent as a standalone operation in patients with OAG in reducing the intraocular pressure (IOP) and the number of topical glaucoma medications. Methods We searched various databases between January 1, 2000, and September 30, 2019, and included only peer-reviewed, prospective, or retrospective clinical studies in our analyses. Details regarding the IOP and the number of medications at baseline and end point were recorded from each study. Standardized mean differences (SMDs) of IOP and medication numbers were calculated. Furthermore, the success rate (the proportion of IOP ≤18 mmHg and IOP reduction ≥20% at end point) and the complication rate were also summarized. Finally, a subgroup analysis was done based on the iStent generation (first and second), follow-up duration (≤6, 6–18, 18–36, and >36 months), and iStent number (one, two, and three). The outcome measures were aggregated SMDs computed from each study. Results A total of 17 studies with 978 eyes were included in this analysis. All studies demonstrated a reduction in IOP after iStent implantation. Aggregated SMDs of IOP revealed a significant reduction (SMD = −2.64, 95% confidence interval (CI): −3.21 to −2.07). The success rate was significantly good, and most of the complication rates were low. The number of medications was also significantly reduced (SMD = −1.71, 95% CI: −2.18 to −1.24). The subgroup analysis revealed a reduction in IOP and medication burden in each category of iStent generation, follow-up duration of up to 42 months, and iStent numbers. Conclusion Use of iStent as a standalone procedure does reduce the IOP and the number of glaucoma medications. The benefit of iStent lasts for at least 42 months.
Collapse
|