1
|
Vauchot F, Dubois J, Bourdon A. Improving multi-pinhole CZT myocardial perfusion imaging specificity without changing sensibility by using adapted filter parameters. EJNMMI Res 2024; 14:27. [PMID: 38453724 PMCID: PMC10920588 DOI: 10.1186/s13550-024-01083-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 02/19/2024] [Indexed: 03/09/2024] Open
Abstract
BACKGROUND Meta-analysis show the diagnostic performance of cardiac dedicated multi-pinhole cadmium-zinc-telluride myocardial perfusion imaging (MPI) with a sensibility around 0.9 and a specificity around 0.7. The aim of the present study is to explore a simple method to generate less artefact on MPI using single photon emission computed tomography (SPECT) and to enhance specificity without changing sensibility. RESULTS From October 2018 to March 2019, 200 patients who underwent SPECT with [99mTc]Tc-tetrofosmin were prospectively recruited: 100 patients with ischemia or necrosis diagnosis (first arm), and 100 patients with myocardial reversible SPECT artefact (second arm). Each SPECT was explored using two image process based on a Butterworth prefilter and post-filter: the original image processing (reconstruction A) with a cut-off frequency equals to 37% of the Nyquist frequency and order equals to 7, and a second image processing (reconstruction B) with a cut-off frequency equals to 25% of the Nyquist frequency and order equals to 5. For each patient, sum stress or rest score with and without septum (SSRS and SSRSws) were calculated with the two reconstructions. No significant statistical difference between SSRSa and SSRSb was identified for the first arm (P = 0.54) and the relative difference ∆r was - 0.5 ± 11.1% (95% CI - 2.7 to 1.7). We found a significant statistical difference between SSRSa and SSRSb for the second arm (p < 0.0001) and the relative difference ∆r was 69.7 ± 16.2% (95% CI 66.6-72.9). CONCLUSION In conclusion, using a Butterworth prefilter and post-filter cut-off frequency equal to 25% of the Nyquist frequency before iterative reconstruction generates less artefact and improves myocardial SPECT specificity without affecting sensibility compared with the original reconstruction.
Collapse
Affiliation(s)
- Fabien Vauchot
- Department of Nuclear Medicine, Montpellier University Hospital, Montpellier, France.
| | - Julien Dubois
- Department of Radiopharmacy, Montpellier University Hospital, Montpellier University, Montpellier, France
| | - Aurélie Bourdon
- Department of Nuclear Medicine, Montpellier University Hospital, Montpellier, France
| |
Collapse
|
2
|
Otaki Y, Manabe O, Miller RJH, Manrique A, Nganoa C, Roth N, Berman DS, Germano G, Slomka PJ, Agostini D. Quantification of myocardial blood flow by CZT-SPECT with motion correction and comparison with 15O-water PET. J Nucl Cardiol 2021; 28:1477-1486. [PMID: 31452085 PMCID: PMC7042031 DOI: 10.1007/s12350-019-01854-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 07/16/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND We compared quantification of MBF and myocardial flow reserve (MFR) with a 99mTc-sestamibi CZT-SPECT to 15O-water PET. METHODS SPECT MBF for thirty patients in the WATERDAY study was re-analyzed by QPET software with motion correction and optimal placement of the arterial input function. 15O-water PET MBF was re-quantified using dedicated software. Inter-operator variability was assessed using repeatability coefficients (RPC). RESULTS Significant correlations were observed between global (r = 0.91, P < 0.001) and regional MBF (r = 0.86, P < 0.001) with SPECT compared to PET. Global MBF (rest 0.95 vs 1.05 ml/min/g, P = 0.07; stress 2.62 vs 2.68 mL/min/g, P = 0.17) and MFR (2.65 vs 2.75, P = 0.86) were similar between SPECT and PET. Rest (0.81 vs 0.98 mL/min/g, P = 0.03) and stress MBF (1.98 vs 2.61 mL/min/g, P = 0.01) in right coronary artery (RCA) were lower with SPECT compared to PET. However, MFR in the RCA territory was similar (2.54 vs 2.77, P = 0.21). The SPECT-PET RPC for global MBFs and MFR were 0.95 mL/min/g and 0.94, with inter-observer RPC of 0.59 mL/min/g and 0.74, respectively. CONCLUSIONS MBF and MFR derived from CZT-SPECT with motion correction and optimal placement of the arterial input function showed good agreement with 15O-water PET, as well as low inter-operator variability.
Collapse
Affiliation(s)
- Yuka Otaki
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Osamu Manabe
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
- Department of Nuclear Medicine, Hokkaido University of Graduate School of Medicine, Sapporo, Japan
| | - Robert J H Miller
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Alain Manrique
- Department of Nuclear Medicine, CHU Cote de Nacre, Normandy University, Caen, France
| | - Catherine Nganoa
- Department of Nuclear Medicine, CHU Cote de Nacre, Normandy University, Caen, France
| | | | - Daniel S Berman
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Guido Germano
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Piotr J Slomka
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
| | - Denis Agostini
- Department of Nuclear Medicine, CHU Cote de Nacre, Normandy University, Caen, France
| |
Collapse
|
3
|
Hage FG, AlJaroudi WA. Review of cardiovascular imaging in the Journal of Nuclear Cardiology 2019: Single-photon emission computed tomography. J Nucl Cardiol 2020; 27:1171-1179. [PMID: 32410057 DOI: 10.1007/s12350-020-02167-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 04/16/2020] [Indexed: 02/07/2023]
Abstract
In 2019, the Journal of Nuclear Cardiology published excellent articles pertaining to imaging in patients with cardiovascular disease. In this review, we will summarize a selection of these articles to provide a concise review of the main advancements that have recently occurred in the field and provide the reader with an opportunity to review a wide selection of articles. In the first article of this 2-part series, we focused on publications dealing with positron emission tomography, computed tomography, and magnetic resonance. This review will place emphasis on myocardial perfusion imaging using single-photon emission computed tomography summarizing advances in the field including in diagnosis and prognosis, non-perfusion variables, safety of testing, imaging in patients with heart failure and renal disease.
Collapse
Affiliation(s)
- Fadi G Hage
- Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham, Lyons Harrison Research Building 306, 1900 University BLVD, Birmingham, AL, 35294, USA.
- Section of Cardiology, Birmingham Veterans Affairs Medical Center, Birmingham, AL, USA.
| | - Wael A AlJaroudi
- Division of Cardiovascular Medicine, Clemenceau Medical Center, Beirut, Lebanon
| |
Collapse
|
4
|
Hyafil F, Gimelli A, Slart RHJA, Georgoulias P, Rischpler C, Lubberink M, Sciagra R, Bucerius J, Agostini D, Verberne HJ. EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras. Eur J Hybrid Imaging 2019; 3:11. [PMID: 34191169 PMCID: PMC8218102 DOI: 10.1186/s41824-019-0058-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 06/10/2019] [Indexed: 01/28/2023] Open
Abstract
An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature.
Collapse
Affiliation(s)
- Fabien Hyafil
- Department of Nuclear Medicine; Bichat University Hospital, Assistance Publique - Hôpitaux de Paris; Inserm UMR 1148, Paris Diderot-Paris 7 University, 46 rue Henri Huchard, 75018, Paris, France.
| | | | - Riemer H J A Slart
- Medical Imaging Center, Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Groningen, The Netherlands
- TechMed Centre, Department of Biomedical Photonic Imaging, University of Twente, Enschede, The Netherlands
| | - Panagiotis Georgoulias
- Department of Nuclear Medicine, University of Thessaly, University Hospital of Larissa, Larissa, Greece
| | - Christoph Rischpler
- Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Mark Lubberink
- Department of Medical Physics and PET Centre, Uppsala University Hospital, Uppsala, Sweden
| | - Roberto Sciagra
- Nuclear Medicine Unit, Department of Experimental and Clinical Biomedical Sciences, University of Florence, Florence, Italy
| | - Jan Bucerius
- Department of Nuclear Medicine, Maastricht University Medical Center and Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
- Department of Nuclear Medicine, University Hospital RWTH Aachen, Aachen, Germany
| | - Denis Agostini
- Department of Nuclear Medicine, CHU Caen Normandy University, Caen, France
| | - Hein J Verberne
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
5
|
Perrin M, Roch V, Claudin M, Verger A, Boutley H, Karcher G, Baumann C, Veran N, Marie PY, Imbert L. Assessment of Myocardial CZT SPECT Recording in a Forward-Leaning Bikerlike Position. J Nucl Med 2019; 60:824-829. [PMID: 30389818 PMCID: PMC6581225 DOI: 10.2967/jnumed.118.217695] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 10/15/2018] [Indexed: 01/04/2023] Open
Abstract
This prospective randomized study assessed myocardial perfusion imaging with the high-sensitivity D.SPECT cadmium-zinc-telluride camera in a forward-leaning bikerlike position, which may potentially lower diaphragmatic attenuation and reduce breathing-related cardiac motion, in a manner comparable to the prone position proposed with other SPECT cameras. Methods: Patients referred for a stress-rest 99mTc-sestamibi protocol and positioned in the biker position, with the chest leaning forward on the D.SPECT camera-head at 35° from vertical, had an additional resting D.SPECT recording in the supine position (n = 40) or in the sitting position with the back rearward at 30° from vertical (n = 40). Segments with attenuation artifacts were defined as those with less than 65% uptake but with strictly normal contractility at gated SPECT and no defect reversibility from stress images. Results: The biker position was associated with lower heart-to-detector distances than the supine or sitting positions (both P < 0.001); lower cardiac motion amplitudes, assessed on panograms, than the supine position (P < 0.001); and fewer segments with attenuation artifacts than the supine position (on average, 1.10 ± 1.01 vs. 1.90 ± 1.74, P = 0.010) or the sitting position (0.75 ± 0.93 vs. 1.38 ± 1.60, P = 0.011). Conclusion: Myocardial perfusion images from D.SPECT are enhanced for patients positioned in a forward-leaning bikerlike position comparatively to sitting or supine positions, with a notably lower rate of attenuation artifacts.
Collapse
Affiliation(s)
- Mathieu Perrin
- Department of Nuclear Medicine, CHRU-Nancy, Nancy, France
| | - Véronique Roch
- Department of Nuclear Medicine, CHRU-Nancy, Nancy, France
| | - Marine Claudin
- Department of Nuclear Medicine, CHRU-Nancy, Nancy, France
| | - Antoine Verger
- Department of Nuclear Medicine, CHRU-Nancy, Nancy, France
- Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Nancy, France
- Université de Lorraine, INSERM, UMR 1254, Nancy, France
| | - Henri Boutley
- Laboratoire de Biophysique and Nancyclotep Molecular Imaging Platform, Université de Lorraine, Nancy, France
| | - Gilles Karcher
- Department of Nuclear Medicine, CHRU-Nancy, Nancy, France
- Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Nancy, France
- Laboratoire de Biophysique and Nancyclotep Molecular Imaging Platform, Université de Lorraine, Nancy, France
| | - Cédric Baumann
- Clinical Research Support Platform, Université de Lorraine, CHRU-Nancy, Nancy, France; and
| | - Nicolas Veran
- Department of Nuclear Medicine, CHRU-Nancy, Nancy, France
| | - Pierre-Yves Marie
- Department of Nuclear Medicine, CHRU-Nancy, Nancy, France
- Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Nancy, France
- Université de Lorraine, INSERM, UMR 1116, Nancy, France
| | - Laetitia Imbert
- Department of Nuclear Medicine, CHRU-Nancy, Nancy, France
- Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Nancy, France
- Université de Lorraine, INSERM, UMR 1254, Nancy, France
| |
Collapse
|