1
|
Ieritano C, Haack A, Hopkins WS. Chemical Transformations Can Occur during DMS Separations: Lessons Learned from Beer's Bittering Compounds. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37310853 DOI: 10.1021/jasms.3c00040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
While developing a DMS-based separation method for beer's bittering compounds, we observed that the argentinated forms of humulone tautomers (i.e., [Hum + Ag]+) were partially resolvable in a N2 environment seeded with 1.5 mol % of isopropyl alcohol (IPA). Attempting to improve the separation by introducing resolving gas unexpectedly caused the peaks for the cis-keto and trans-keto tautomers of [Hum + Ag]+ to coalesce. To understand why resolution loss occurred, we first confirmed that each of the tautomeric forms (i.e., dienol, cis-keto, and trans-keto) responsible for the three peaks in the [Hum + Ag]+ ionogram were assigned to the correct species by employing collision-induced dissociation, UV photodissociation spectroscopy, and hydrogen-deuterium exchange (HDX). The observation of HDX indicated that proton transfer was stimulated by dynamic clustering processes between IPA and [Hum + Ag]+ during DMS transit. Because IPA accretion preferentially occurs at Ag+, which can form pseudocovalent bonds with a suitable electron donor, solvent clustering also facilitated the formation of exceptionally stable microsolvated ions. The exceptional stability of these microsolvated configurations disproportionately impacted the compensation voltage (CV) required to elute each tautomer when the temperature within the DMS cell was varied. The disparity in CV response caused the peaks for the cis- and trans-keto species to merge when a temperature gradient was induced by the resolving gas. Moreover, simulations showed that microsolvation with IPA mediates dienol to trans-keto tautomerization during DMS transit, which, to the best of our knowledge, is the first observation of keto/enol tautomerization occurring within an ion-mobility device.
Collapse
Affiliation(s)
- Christian Ieritano
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
- Watermine Innovation, Waterloo, Ontario N0B 2T0, Canada
| | - Alexander Haack
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
- Watermine Innovation, Waterloo, Ontario N0B 2T0, Canada
- Centre for Eye and Vision Research, 17 W Hong Kong Science Park, Shatin, New Territories 999077, Hong Kong
| |
Collapse
|
2
|
Du X, Wang Y, Zeng H, Zeng H, Chen Z, Li H. High-field asymmetric waveform ion mobility spectrometry for xylene isomer separation assisted by helium-chemical modifiers. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:4649-4658. [PMID: 36377690 DOI: 10.1039/d2ay01098d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
We propose a combined helium-chemical modifier method for a faster and more convenient separation and detection of xylene isomers. The method employs high-field asymmetric waveform ion mobility spectrometry (FAIMS) to investigate the separation and identification of three xylene isomers. A homemade hollow needle-ring ion source was used, and five chemical modifiers, represented by methanol, ethanol, acetone, ethyl acetate, and acetic acid, were doped into the xylene target analytes to observe the separation and identification of the three isomers. This was based on the fact that the addition of helium and the increase of the RF voltage could no longer improve the resolution of the field asymmetric waveform ion mobility spectrometry system. The experimental results at an RF field voltage of 15 kV cm-1 showed that the spectral peak shifts of o-, m-, and p-xylene in a normal nitrogen environment were -0.21, -0.21, and -0.24 V, respectively. o-Xylene showed a spectral peak of -1.33 V after the addition of helium; however, the separation was not evident. The FAIMS spectrum of xylene showed multiple cluster ion peaks upon addition of the chemical modifiers on top of helium. The alcohol chemical modifiers caused three spectral peaks, with the best effect for methanol, and the characteristic ion peak positions of -7.16, -6.90, and -6.01 V for o-, m-, and p-xylene, respectively. The separation using proton-based chemical modifiers was confirmed to be stronger than that using non-proton-based chemical modifiers, and appropriate volume fractions of chemical modifiers provided a better separation of the target analytes. This study introduces a novel concept and method for the separation and identification of xylene isomers.
Collapse
Affiliation(s)
- Xiaoxia Du
- School of Life and Environmental Sciences, GuiLin University of Electronic Technology, GuiLin 541004, China.
| | - Yifei Wang
- School of Life and Environmental Sciences, GuiLin University of Electronic Technology, GuiLin 541004, China.
| | - Hongda Zeng
- School of Life and Environmental Sciences, GuiLin University of Electronic Technology, GuiLin 541004, China.
| | - Hao Zeng
- School of Life and Environmental Sciences, GuiLin University of Electronic Technology, GuiLin 541004, China.
| | - Zhencheng Chen
- School of Life and Environmental Sciences, GuiLin University of Electronic Technology, GuiLin 541004, China.
| | - Hua Li
- School of Life and Environmental Sciences, GuiLin University of Electronic Technology, GuiLin 541004, China.
| |
Collapse
|
3
|
Paglia G, Smith AJ, Astarita G. Ion mobility mass spectrometry in the omics era: Challenges and opportunities for metabolomics and lipidomics. MASS SPECTROMETRY REVIEWS 2022; 41:722-765. [PMID: 33522625 DOI: 10.1002/mas.21686] [Citation(s) in RCA: 96] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 01/17/2021] [Accepted: 01/17/2021] [Indexed: 06/12/2023]
Abstract
Researchers worldwide are taking advantage of novel, commercially available, technologies, such as ion mobility mass spectrometry (IM-MS), for metabolomics and lipidomics applications in a variety of fields including life, biomedical, and food sciences. IM-MS provides three main technical advantages over traditional LC-MS workflows. Firstly, in addition to mass, IM-MS allows collision cross-section values to be measured for metabolites and lipids, a physicochemical identifier related to the chemical shape of an analyte that increases the confidence of identification. Second, IM-MS increases peak capacity and the signal-to-noise, improving fingerprinting as well as quantification, and better defining the spatial localization of metabolites and lipids in biological and food samples. Third, IM-MS can be coupled with various fragmentation modes, adding new tools to improve structural characterization and molecular annotation. Here, we review the state-of-the-art in IM-MS technologies and approaches utilized to support metabolomics and lipidomics applications and we assess the challenges and opportunities in this growing field.
Collapse
Affiliation(s)
- Giuseppe Paglia
- School of Medicine and Surgery, University of Milano-Bicocca, Vedano al Lambro (MB), Italy
| | - Andrew J Smith
- School of Medicine and Surgery, University of Milano-Bicocca, Vedano al Lambro (MB), Italy
| | - Giuseppe Astarita
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University, Washington, District of Columbia, USA
| |
Collapse
|
4
|
Lee J, Clowers BH, Hogan CJ. Condensable Vapor Sorption by Low Charge State Protein Ions. Anal Chem 2022; 94:7050-7059. [PMID: 35500255 DOI: 10.1021/acs.analchem.2c00357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Measurement of the gas-phase ion mobility of proteins provides a means to quantitatively assess the relative sizes of charged proteins. However, protein ion mobility measurements are typically singular values. Here, we apply tandem mobility analysis to low charge state protein ions (+1 and +2 ions) introduced into the gas phase by nanodroplet nebulization. We first determine protein ion mobilities in dry air and subsequently examine shifts in mobilities brought about by the clustering of vapor molecules. Tandem mobility analysis yields mobility-vapor concentration curves for each protein ion, expanding the information obtained from mobility analysis. This experimental procedure and analysis is extended to bovine serum albumin, transferrin, immunoglobulin G, and apoferritin with water, 1-butanol, and nonane. All protein ions appear to adsorb vapor molecules, with mobility "diameter" shifts of up to 6-7% at conditions just below vapor saturation. We parametrize results using κ-Köhler theory, where the term κ quantifies the extent of uptake beyond Köhler model expectations. For 1-butanol and nonane, κ decreases with increasing protein ion size, while it increases with increasing protein ion size for water. For the systems probed, the extent of mobility shift for the organic vapors is unaffected by the nebulized solution pH, while shifts with water are sensitive to pH.
Collapse
Affiliation(s)
- Jihyeon Lee
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Brian H Clowers
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
| | - Christopher J Hogan
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
5
|
Wang DD, Wang J. Characterization of Allergic Polymerized Impurities in Cephalosporins by MALDI-TOF MS/MS Spectrometry. CURR PHARM ANAL 2022. [DOI: 10.2174/1573412918666220330003952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Characterization of allergic polymerized impurities in cephalosporins is significant to ensure the safety and quality of the products.
Objective:
To develop a MALDI-TOF MS/MS method to characterize the structures of polymerized impurities in cefuroxime axetil drug substance and cefetamet pivoxil drug substance.
Methods:
Calibrant references were TOF mix, including Angiotensin 2, Angiotensin 1, Glu-1-fibrino, N-Acetyl renin, ACTH 1-17, ACTH 18-39 and ACTH 7-38. Matrix was DHB at a concentration of 10 mg•mL-1. Acetone and water were used as solvent to dissolve cefuroxime axetil and cefetamet pivoxil hydrochloride drug substances, respectively. The prepared solutions were mixed with DHB, volatilized to dry, and subjected to MALDI-TOF MS/MS analysis, respectively. MS data was obtained in the linear mode with a power of 80, and MS2 data was obtained in the reflection mode with a power of 120. Molecular weights of polymerized impurities in cefuroxime axetil and cefetamet pivoxil were obtained based on the MS data. Their fragmentation patterns and structural assignments were studied based on the MS2 data.
Results:
Eight polymerized impurities in cefuroxime axetil drug substance and cefetamet pivoxil hydrochloride drug substance made in China were characterized by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS/MS), among which impurity Ⅰ-Ⅴ were in cefuroxime axetil and impurities Ⅵ-Ⅷ were in cefetamet pivoxil. Based on the experimental results, the polymerization mechanism of polymerized impurities in cephalosporins was discussed.
Conclusion:
MALDI-TOF MS/MS was proved to be simple, quick and sensitive for the analysis of polymerized impurities in cephalosporins.
Collapse
Affiliation(s)
- Dan-dan Wang
- Zhejiang Institute for Food and Drug Control, Hangzhou, China
- Key Laboratory of Drug Contacting Materials Quality Control of Zhejiang Province, Hangzhou, China
| | - Jian Wang
- Zhejiang Institute for Food and Drug Control, Hangzhou, China
| |
Collapse
|
6
|
Zhang J, Hu L, Shao H. Research Progress on Quantification Methods of Drug Concentration of Monoclonal Antibodies. CURR PHARM ANAL 2022. [DOI: 10.2174/1573412918666220329110712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
With the development of monoclonal antibodies (mAbs) from the first generation of mice to the fourth generation of human origin, the efficacy and safety in the treatment of many diseases have been continuously improved. MAbs have been widely used in the treatment of cancer, chronic inflammatory diseases, and so on. However, the treatment response of mAbs varies greatly among individuals, and drug exposure may be affected by a variety of physiological and pathological factors, such as combined use of drugs and progression of disease. Therefore, studies tend to recommend therapeutic drug monitoring and individualized treatment strategies.
Objective:
In this paper, the commonly used methods of quantification of monoclonal antibodies were reviewed, especially liquid chromatography- mass spectrometry (LC-MS/MS) and enzyme-linked immunosorbent assay (ELISA), to provide technical support for therapeutic drug detection and individualize dosing for patients.
Conclusion:
For patients achieving mAbs treatment, it is necessary to carry out therapeutic drug monitoring and take it as a routine monitoring index. We recommend that for pharmaceutical laboratories in hospitals, establishing an appropriate assay formats, such as ELISA and LC-MS/MS is critical to determine drug concentration and antidrug antibody (ADA) for mAbs.
Collapse
Affiliation(s)
- Jinlu Zhang
- School of Medicine, Southeast University, Nanjing, China
| | - Linlin Hu
- Office of Medication Clinical Institution, Zhongda Hospital, Southeast University, Nanjing, China;
- Department of Pharmacy, Zhongda Hospital, Southeast University, Nanjing, China
| | - Hua Shao
- Department of Pharmacy, Zhongda Hospital, Southeast University, Nanjing, China
| |
Collapse
|
7
|
Meta-proteomic analysis of two mammoth's trunks by EVA technology and high-resolution mass spectrometry for an indirect picture of their habitat and the characterization of the collagen type I, alpha-1 and alpha-2 sequence. Amino Acids 2022; 54:935-954. [PMID: 35434776 PMCID: PMC9213349 DOI: 10.1007/s00726-022-03160-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 03/27/2022] [Indexed: 12/30/2022]
Abstract
The recent paleoproteomic studies, including paleo-metaproteomic analyses, improved our understanding of the dietary of ancient populations, the characterization of past human diseases, the reconstruction of the habitat of ancient species, but also provided new insights into the phylogenetic relationships between extant and extinct species. In this respect, the present work reports the results of the metaproteomic analysis performed on the middle part of a trunk, and on the portion of a trunk tip tissue of two different woolly mammoths some 30,000 years old. In particular, proteins were extracted by applying EVA (Ethylene-Vinyl Acetate studded with hydrophilic and hydrophobic resins) films to the surface of these tissues belonging to two Mammuthus primigenus specimens, discovered in two regions located in the Russian Far East, and then investigated via a shotgun MS-based approach. This approach allowed to obtain two interesting results: (i) an indirect description of the habitat of these two mammoths, and (ii) an improved characterization of the collagen type I, alpha-1 and alpha-2 chains (col1a1 and col1a2). Sequence characterization of the col1a1 and col1a2 highlighted some differences between M. primigenius and other Proboscidea together with the identification of three (two for col1a1, and one for col1a2) potentially diagnostic amino acidic mutations that could be used to reliably distinguish the Mammuthus primigenius with respect to the other two genera of elephantids (i.e., Elephas and Loxodonta), and the extinct American mastodon (i.e., Mammut americanum). The results were validated through the level of deamidation and other diagenetic chemical modifications of the sample peptides, which were used to discriminate the "original" endogenous peptides from contaminant ones. The data have been deposited to the ProteomeXchange with identifier < PXD029558 > .
Collapse
|
8
|
Slifer ZM, Hernandez L, Pridgen TA, Carlson AR, Messenger KM, Madan J, Krishnan BR, Laumas S, Blikslager AT. Larazotide acetate induces recovery of ischemia-injured porcine jejunum via repair of tight junctions. PLoS One 2021; 16:e0250165. [PMID: 33886649 PMCID: PMC8061941 DOI: 10.1371/journal.pone.0250165] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 03/31/2021] [Indexed: 12/14/2022] Open
Abstract
Intestinal ischemia results in mucosal injury, including paracellular barrier loss due to disruption of tight junctions. Larazotide acetate (LA), a small peptide studied in Phase III clinical trials for treatment of celiac disease, regulates tight junctions (TJs). We hypothesized that LA would dose-dependently hasten recovery of intestinal ischemic injury via modulation of TJs. Ischemia-injured tissue from 6-8-week-old pigs was recovered in Ussing chambers for 240-minutes in the presence of LA. LA (1 μM but not 0.1 μM or 10 μM) significantly enhanced transepithelial electrical resistance (TER) above ischemic injured controls and significantly reduced serosal-to-mucosal flux LPS (P<0.05). LA (1 μM) enhanced localization of the sealing tight junction protein claudin-4 in repairing epithelium. To assess for the possibility of fragmentation of LA, an in vitro enzyme degradation assay using the brush border enzyme aminopeptidase M, revealed generation of peptide fragments. Western blot analysis of total protein isolated from uninjured and ischemia-injured porcine intestine showed aminopeptidase M enzyme presence in both tissue types, and mass spectrometry analysis of samples collected during ex vivo analysis confirmed formation of LA fragments. Treatment of tissues with LA fragments had no effect alone, but treatment with a fragment missing both amino-terminus glycines inhibited barrier recovery stimulated by 1 μM LA. To reduce potential LA inhibition by fragments, a D-amino acid analog of larazotide Analog #6, resulted in a significant recovery response at a 10-fold lower dose (0.1 μM) similar in magnitude to that of 1 μM LA. We conclude that LA stimulates repair of ischemic-injured epithelium at the level of the tight junctions, at an optimal dose of 1 μM LA. Higher doses were less effective because of inhibition by LA fragments, which could be subverted by chirally-modifying the molecule, or microdosing LA.
Collapse
Affiliation(s)
- Zachary M. Slifer
- Comparative Medicine Institute, Department of Clinical Sciences, North Carolina State University, Raleigh, NC, United States of America
| | - Liliana Hernandez
- Comparative Medicine Institute, Department of Clinical Sciences, North Carolina State University, Raleigh, NC, United States of America
| | - Tiffany A. Pridgen
- Comparative Medicine Institute, Department of Clinical Sciences, North Carolina State University, Raleigh, NC, United States of America
| | - Alexandra R. Carlson
- Comparative Medicine Institute, Department of Clinical Sciences, North Carolina State University, Raleigh, NC, United States of America
| | - Kristen M. Messenger
- Comparative Medicine Institute, Department of Clinical Sciences, North Carolina State University, Raleigh, NC, United States of America
| | - Jay Madan
- Innovate Biopharmaceuticals, Inc., Raleigh, NC, United States of America
| | - B. Radha Krishnan
- Innovate Biopharmaceuticals, Inc., Raleigh, NC, United States of America
| | - Sandeep Laumas
- 9 Meters Biopharma, Inc., Raleigh, NC, United States of America
| | - Anthony T. Blikslager
- Comparative Medicine Institute, Department of Clinical Sciences, North Carolina State University, Raleigh, NC, United States of America
- * E-mail:
| |
Collapse
|
9
|
Vera NB, Coy SL, Laiakis EC, Fornace AJ, Clasquin M, Barker CA, Pfefferkorn JA, Vouros P. Quantitation of Urinary Acylcarnitines by DMS-MS/MS Uncovers the Effects of Total Body Irradiation in Cancer Patients. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:498-507. [PMID: 32013416 PMCID: PMC7489307 DOI: 10.1021/jasms.9b00076] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Acylcarnitines have been identified in human and animal metabolomic-profiling studies as urinary markers of radiation exposure, a result which is consistent with their cytoprotective effects and roles in energy metabolism. In the present work, a rapid method for quantitation of the more abundant acylcarnitines in human urine is developed using a valuable set of samples from cancer patients who received total body irradiation (TBI) at Memorial Sloan Kettering Cancer Center. The method uses solid-phase extraction (SPE) processing followed by differential mobility spectrometry (DMS with ethyl acetate modifier) tandem mass spectrometry (ESI-DMS-MS/MS) with deuterated internal standards. The analyzed human urine samples were collected from 38 individual patients at three time points over 24 h during and after the course of radiation treatment, a design allowing each patient to act as their own control and creatinine normalization. Creatinine-normalized concentrations for nine urinary acylcarnitine (acyl-CN) species are reported. Six acyl-CN species were reduced at the 6 h point. Acetylcarnitine (C2:0-CN) and valerylcarnitine (C5:0-CN) showed recovery at 24 h, but none of the other acyl-CN species showed recovery at that point. Levels of three acyl-CN species were not significantly altered by radiation. This rapid quantitative method for clinical samples covers the short- and medium-chain acylcarnitines and has the flexibility to be expanded to cover additional radiation-linked metabolites. The human data presented here indicates the utility of the current approach as a rapid, quantitative technique with potential applications by the medical community, by space research laboratories concerned with radiation exposure, and by disaster response groups.
Collapse
Affiliation(s)
- Nicholas B. Vera
- Pfizer Global Research and Development, Cambridge Laboratories, Pfizer Inc., Cambridge, Massachusetts 02139 United States
- Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 02115 United States
| | - Stephen L. Coy
- Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 02115 United States
| | - Evagelia C. Laiakis
- Department of Oncology, Georgetown University, 3700 O Street NW, Washington, D.C. 20057 United States
- Department of Biochemistry and Molecular & Cellular Oncology, Georgetown University, 3700 O Street NW, Washington D.C. 20057 United States
| | - Albert J. Fornace
- Department of Oncology, Georgetown University, 3700 O Street NW, Washington, D.C. 20057 United States
- Department of Biochemistry and Molecular & Cellular Oncology, Georgetown University, 3700 O Street NW, Washington D.C. 20057 United States
| | - Michelle Clasquin
- Pfizer Global Research and Development, Cambridge Laboratories, Pfizer Inc., Cambridge, Massachusetts 02139 United States
| | - Christopher A. Barker
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York 10065, United States
| | - Jeffrey A. Pfefferkorn
- Pfizer Global Research and Development, Cambridge Laboratories, Pfizer Inc., Cambridge, Massachusetts 02139 United States
| | - Paul Vouros
- Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 02115 United States
| |
Collapse
|
10
|
Morris CB, Poland JC, May JC, McLean JA. Fundamentals of Ion Mobility-Mass Spectrometry for the Analysis of Biomolecules. Methods Mol Biol 2020; 2084:1-31. [PMID: 31729651 DOI: 10.1007/978-1-0716-0030-6_1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Ion mobility-mass spectrometry (IM-MS) combines complementary size- and mass-selective separations into a single analytical platform. This chapter provides context for both the instrumental arrangements and key application areas that are commonly encountered in bioanalytical settings. New advances in these high-throughput strategies are described with description of complementary informatics tools to effectively utilize these data-intensive measurements. Rapid separations such as these are especially important in systems, synthetic, and chemical biology in which many small molecules are transient and correspond to various biological classes for integrated omics measurements. This chapter highlights the fundamentals of IM-MS and its applications toward biomolecular separations and discusses methods currently being used in the fields of proteomics, lipidomics, and metabolomics.
Collapse
Affiliation(s)
- Caleb B Morris
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Vanderbilt University, Nashville, TN, USA.,Vanderbilt-Ingram Cancer Center, Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, TN, USA
| | - James C Poland
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Vanderbilt University, Nashville, TN, USA.,Vanderbilt-Ingram Cancer Center, Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, TN, USA
| | - Jody C May
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Vanderbilt University, Nashville, TN, USA.,Vanderbilt-Ingram Cancer Center, Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, TN, USA
| | - John A McLean
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Vanderbilt University, Nashville, TN, USA. .,Vanderbilt-Ingram Cancer Center, Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, TN, USA.
| |
Collapse
|
11
|
Quantitation of Cyclosporin A in Cell Culture Media by Differential Mobility Mass Spectrometry (DMS-MS/MS). Methods Mol Biol 2019. [PMID: 31729659 DOI: 10.1007/978-1-0716-0030-6_9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Cell permeability is an important factor in determining the bioavailability of therapeutics that is usually measured by cell culture testing. The concentration of pharmaceutical in a medium such as Hank's Balanced Salt Solution with HEPES organic buffer (HBSS-HEPES) is measured at a series of time points, making simplicity and high throughput of the analytical method important characteristics. We report an electrospray differential mobility spectrometry mass spectrometry method (nanoESI-DMS-MS) for the rapid determination of cyclosporin A (CsA, cyclosporine) concentration in such a buffer. DMS technology provides gas phase atmospheric pressure ion filtration for small-molecule bioanalytical methods that suppresses interfering ions and reduces chemical noise, without the use of chromatography. This allows simplified sample preparation, fast calibration curve development, and shortened analysis times. It has also been noted that the DMS prefilter can reduce contamination of the mass spectrometer by salts, thereby extending mass spectrometer system uptime.In the application described here, DMS-MS/MS is applied to cyclosporine A (CsA) in cell medium. Sample preparation is limited to dilution with an ammonium acetate-methanol-water mobile phase and the addition of CsA-d4 internal standard. The isotope ratio data are obtained in DMS-MS MRM mode observing NH3 loss from the ammonium adduct of the two species. A calibration curve with high linearity (R2 = 0.998) is rapidly obtained with nearly zero intercept, while it was found that a liquid chromatography LC-MS method required a preliminary SPE step to obtain a linear calibration curve. The time for data acquisition in the DMS-MS MRM method with flow injection (FIA) or infusion introduction at ESI flow of 400 nL/min is typically 30 s leading to a cycle time of less than 1 min.
Collapse
|
12
|
The Use of DMS-MS for the Quantitative Analysis of Acylcarnitines. Methods Mol Biol 2019. [PMID: 31729655 DOI: 10.1007/978-1-0716-0030-6_5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Differential mobility spectrometry (DMS) is capable of separating molecules based on their size and shape. When coupled to mass spectrometry (MS), DMS reduces chemical background and enhances signal-to-noise (S/N) ratio. Flow injection analysis (FIA) is a technique used to introduce samples into the source of the DMS-MS platform. Here we describe the application of FIA-DMS-MS/MS for the analysis of urinary acylcarnitine species. More than 20 acylcarnitine species can be detected and quantified during a single FIA-DMS-MS/MS acquisition.
Collapse
|
13
|
Wu R, Chen X, Wu WJ, Wang Z, Wong YLE, Hung YLW, Wong HT, Yang M, Zhang F, Chan TWD. Rapid Differentiation of Asian and American Ginseng by Differential Ion Mobility Spectrometry-Tandem Mass Spectrometry Using Stepwise Modulation of Gas Modifier Concentration. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:2212-2221. [PMID: 31502223 DOI: 10.1007/s13361-019-02317-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 07/21/2019] [Accepted: 08/10/2019] [Indexed: 06/10/2023]
Abstract
This study reports a rapid and robust method for the differentiation of Asian and American ginseng samples based on differential ion mobility spectrometry-tandem mass spectrometry (DMS-MS/MS). Groups of bioactive ginsenoside/pseudo-ginsenoside isomers, including Rf/Rg1/F11, Rb2/Rb3/Rc, and Rd/Re, in the ginseng extracts were sequentially separated using DMS with stepwise changes in the gas modifier concentration prior to MS analysis. The identities of the spatially separated ginsenoside/pseudo-ginsenoside isomers were confirmed by their characteristic compensation voltages at specific modifier loading and MS/MS product ions. As expected, Asian ginseng samples contained some Rf and an insignificant amount of F11, whereas American ginseng samples had a high level of F11 but no Rf. The origin of the whole and sliced ginseng could further be confirmed using the quantitative ratios of three sets of ginsenoside markers, namely, Rg1/Re, Rb1/Rg1, and Rb2/Rc. Based on our results, new benchmark ratios of Rg1/Re < 0.15, Rb1/Rg1 > 2.15, and Rb2/Rc < 0.26 were proposed for American ginseng (as opposed to Asian ginseng).
Collapse
Affiliation(s)
- Ri Wu
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, People's Republic of China
| | - Xiangfeng Chen
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, People's Republic of China.
- Shandong Analysis and Test Centre, Qilu University of Technology (Shandong Academy of Sciences), Jinan, Shandong, People's Republic of China.
| | - Wei-Jing Wu
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, People's Republic of China
| | - Ze Wang
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, People's Republic of China
| | - Y-L Elaine Wong
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, People's Republic of China
| | - Y-L Winnie Hung
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, People's Republic of China
| | - H-T Wong
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, People's Republic of China
| | - Minli Yang
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing, 100123, China
| | - Feng Zhang
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing, 100123, China
| | - T-W Dominic Chan
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, People's Republic of China.
| |
Collapse
|
14
|
Coughlan NJA, Liu C, Lecours MJ, Campbell JL, Hopkins WS. Preferential Ion Microsolvation in Mixed-Modifier Environments Observed Using Differential Mobility Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:2222-2227. [PMID: 31529402 DOI: 10.1007/s13361-019-02332-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 08/20/2019] [Accepted: 08/27/2019] [Indexed: 06/10/2023]
Abstract
The preferential solvation behavior for eight different derivatives of protonated quinoline was measured in a tandem differential mobility spectrometer mass spectrometer (DMS-MS). Ion-solvent cluster formation was induced in the DMS by the addition of chemical modifiers (i.e., solvent vapors) to the N2 buffer gas. To determine the effect of more than one modifier in the DMS environment, we performed DMS experiments with varying mixtures of water, acetonitrile, and isopropyl alcohol solvent vapors. The results show that doping the buffer gas with a binary mixture of modifiers leads to the ions binding preferentially to one modifier over another. We used density functional theory to calculate the ion-solvent binding energies, and in all cases, calculations show that the quinolinium ions bind most strongly with acetonitrile, then isopropyl alcohol, and most weakly with water. Computational results support the hypothesis that the quinolinium ions bind exclusively to whichever solvent they have the strongest interaction with, regardless of the presence of other modifier gases.
Collapse
Affiliation(s)
- Neville J A Coughlan
- Department of Chemistry, University of Waterloo, 200 University Ave. W., Waterloo, ON, N2L 3G1, Canada
| | - Chang Liu
- SCIEX, Four Valley Dr., Concord, ON, L4K 4V8, Canada
| | - Michael J Lecours
- Department of Chemistry, University of Waterloo, 200 University Ave. W., Waterloo, ON, N2L 3G1, Canada
| | - J Larry Campbell
- Department of Chemistry, University of Waterloo, 200 University Ave. W., Waterloo, ON, N2L 3G1, Canada.
- SCIEX, Four Valley Dr., Concord, ON, L4K 4V8, Canada.
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Ave. W., Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
15
|
Morris CB, May JC, Leaptrot KL, McLean JA. Evaluating Separation Selectivity and Collision Cross Section Measurement Reproducibility in Helium, Nitrogen, Argon, and Carbon Dioxide Drift Gases for Drift Tube Ion Mobility-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:1059-1068. [PMID: 30887459 PMCID: PMC6520154 DOI: 10.1007/s13361-019-02151-4] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 02/05/2019] [Accepted: 02/06/2019] [Indexed: 05/04/2023]
Abstract
Previous ion mobility (IM) studies have demonstrated that varying the drift gas composition can be used to enhance chemical selectivity and resolution, yet there are few drift gas studies aimed at achieving quantitatively reproducible mobility measurements. Here, we critically evaluate the conditions necessary to achieve reproducible collision cross section (CCS) measurements in pure drift gases (helium, nitrogen, argon, and carbon dioxide) using a commercial uniform field drift tube instrument. Optimal experimental parameters are assessed based on the convergence of CCS measurements to reproducible values which are compared with literature values. A suite of calibration standards with diverse masses, biological classes, and charge states are examined to assess chemical selectivity and resolution achievable in each drift gas. Results indicate nitrogen and argon perform similarly and are sufficient for most applications where high resolving power and high peak capacity are desired. Carbon dioxide exhibits more selectivity for resolving structurally heterogeneous compounds, which may be preferable in specific analyte pair separations. Helium demonstrated modest separation capabilities but has utility for comparison to theoretical values and previously published work. In drift gases other than nitrogen, pressure differentials up to 230 mTorr between the drift tube and upstream chamber were optimal for improving correlation to literature values, while in nitrogen, the recommended pressure differential of 150 mTorr was found appropriate. We present recommended experimental parameters as well as gas-specific CCS measurements for structurally homogeneous sets of analytes which are suitable for use by other laboratories as standards for purposes of instrument calibration and overall assessment of IM separation performance.
Collapse
Affiliation(s)
- Caleb B Morris
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Jody C May
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Katrina L Leaptrot
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - John A McLean
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA.
| |
Collapse
|
16
|
Morris CB, May JC, Leaptrot KL, McLean JA. Evaluating Separation Selectivity and Collision Cross Section Measurement Reproducibility in Helium, Nitrogen, Argon, and Carbon Dioxide Drift Gases for Drift Tube Ion Mobility-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:1059-1068. [PMID: 30887459 DOI: 10.1021/jasms.8b06014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 02/05/2019] [Accepted: 02/06/2019] [Indexed: 05/18/2023]
Abstract
Previous ion mobility (IM) studies have demonstrated that varying the drift gas composition can be used to enhance chemical selectivity and resolution, yet there are few drift gas studies aimed at achieving quantitatively reproducible mobility measurements. Here, we critically evaluate the conditions necessary to achieve reproducible collision cross section (CCS) measurements in pure drift gases (helium, nitrogen, argon, and carbon dioxide) using a commercial uniform field drift tube instrument. Optimal experimental parameters are assessed based on the convergence of CCS measurements to reproducible values which are compared with literature values. A suite of calibration standards with diverse masses, biological classes, and charge states are examined to assess chemical selectivity and resolution achievable in each drift gas. Results indicate nitrogen and argon perform similarly and are sufficient for most applications where high resolving power and high peak capacity are desired. Carbon dioxide exhibits more selectivity for resolving structurally heterogeneous compounds, which may be preferable in specific analyte pair separations. Helium demonstrated modest separation capabilities but has utility for comparison to theoretical values and previously published work. In drift gases other than nitrogen, pressure differentials up to 230 mTorr between the drift tube and upstream chamber were optimal for improving correlation to literature values, while in nitrogen, the recommended pressure differential of 150 mTorr was found appropriate. We present recommended experimental parameters as well as gas-specific CCS measurements for structurally homogeneous sets of analytes which are suitable for use by other laboratories as standards for purposes of instrument calibration and overall assessment of IM separation performance.
Collapse
Affiliation(s)
- Caleb B Morris
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Jody C May
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - Katrina L Leaptrot
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA
| | - John A McLean
- Center for Innovative Technology, Department of Chemistry, Vanderbilt Institute of Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, USA.
| |
Collapse
|
17
|
Wei MS, Kemperman RHJ, Yost RA. Effects of Solvent Vapor Modifiers for the Separation of Opioid Isomers in Micromachined FAIMS-MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:731-742. [PMID: 30877655 DOI: 10.1007/s13361-019-02175-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2018] [Revised: 02/24/2019] [Accepted: 02/27/2019] [Indexed: 06/09/2023]
Abstract
Opioid addiction is an escalating problem that is compounded by the introduction of synthetic opiate analogues such as fentanyl. Screening methods for these compound classes are challenged by the availability of synthetically manufactured analogues, including isomers of existing substances. High-field asymmetric-waveform ion mobility spectrometry (FAIMS) utilizes an alternating asymmetric electric field to separate ions by their different mobilities at high and low fields as they travel through the separation space. When coupled to mass spectrometry (MS), FAIMS enhances the separation of analytes from other interfering compounds with little to no increase in analysis time. Addition of solvent vapor into the FAIMS carrier gas has been demonstrated to enable and improve the separation of isomers. Here we investigate the effects of several solvents for the separation of four opioids. FAIMS-MS spectra with added solvent vapors show dramatic compensation field (CF) shifts for opioid [M+H]+ ions when compared to spectra acquired using dry nitrogen. Addition of vapor from aprotic solvents, such as acetonitrile and acetone, produces significantly improved resolution between the tested opioids, with baseline resolution achieved between certain opioid isomers. For protic solvents, notable CF shift differences were observed in FAIMS separations between addition of water vapor and vapors from small alcohols. Graphical Abstract.
Collapse
Affiliation(s)
- Michael S Wei
- Department of Chemistry, University of Florida, 214 Leigh Hall, 117200, Gainesville, FL, 32611, USA
| | - Robin H J Kemperman
- Department of Chemistry, University of Florida, 214 Leigh Hall, 117200, Gainesville, FL, 32611, USA
| | - Richard A Yost
- Department of Chemistry, University of Florida, 214 Leigh Hall, 117200, Gainesville, FL, 32611, USA.
| |
Collapse
|
18
|
Chen Z, Coy SL, Pannkuk EL, Laiakis EC, Fornace AJ, Vouros P. Differential Mobility Spectrometry-Mass Spectrometry (DMS-MS) in Radiation Biodosimetry: Rapid and High-Throughput Quantitation of Multiple Radiation Biomarkers in Nonhuman Primate Urine. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:1650-1664. [PMID: 29736597 PMCID: PMC6287943 DOI: 10.1007/s13361-018-1977-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 04/19/2018] [Accepted: 04/21/2018] [Indexed: 05/21/2023]
Abstract
High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. Graphical Abstract.
Collapse
Affiliation(s)
- Zhidan Chen
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA, 02115, USA
| | - Stephen L Coy
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA, 02115, USA.
| | - Evan L Pannkuk
- Tumor Biology Program, Lombardi Comprehensive Cancer Center, Georgetown University, Washington, DC, 20057, USA
| | - Evagelia C Laiakis
- Department of Biochemistry and Molecular and Cellular Biology, Georgetown University Medical Center, Washington, DC, 20057, USA
| | - Albert J Fornace
- Department of Biochemistry and Molecular and Cellular Biology, Georgetown University Medical Center, Washington, DC, 20057, USA
- Department of Oncology, Georgetown University Medical Center, Washington, DC, 20057, USA
| | - Paul Vouros
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA, 02115, USA.
- Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA, 02115, USA.
| |
Collapse
|
19
|
Vera NB, Chen Z, Pannkuk E, Laiakis EC, Fornace AJ, Erion DM, Coy SL, Pfefferkorn JA, Vouros P. Differential mobility spectrometry (DMS) reveals the elevation of urinary acetylcarnitine in non-human primates (NHPs) exposed to radiation. JOURNAL OF MASS SPECTROMETRY : JMS 2018; 53:548-559. [PMID: 29596720 PMCID: PMC6030448 DOI: 10.1002/jms.4085] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Revised: 03/08/2018] [Accepted: 03/12/2018] [Indexed: 05/21/2023]
Abstract
Acetylcarnitine has been identified as one of several urinary biomarkers indicative of radiation exposure in adult rhesus macaque monkeys (non-human primates, NHPs). Previous work has demonstrated an up-regulated dose-response profile in a balanced male/female NHP cohort. As a contribution toward the development of metabolomics-based radiation biodosimetry in human populations and other applications of acetylcarnitine screening, we have developed a quantitative, high-throughput method for the analysis of acetylcarnitine. We employed the Sciex SelexIon DMS-MS/MS QTRAP 5500 platform coupled to flow injection analysis (FIA), thereby allowing for fast analysis times of less than 0.5 minutes per injection with no chromatographic separation. Ethyl acetate is used as a DMS modifier to reduce matrix chemical background. We have measured NHP urinary acetylcarnitine from the male cohorts that were exposed to the following radiation levels: control, 2, 4, 6, 7, and 10 Gy. Biological variability, along with calibration accuracy of the FIA-DMS-MS/MS method, indicates LOQ of 20 μM, with observed biological levels on the order of 600 μM and control levels near 10 μM. There is an apparent onset of intensified response in the transition from 6 to 10 Gy. The results demonstrate that FIA-DMS-MS/MS is a rapid, quantitative technique that can be utilized for the analysis of urinary biomarker levels for radiation biodosimetry.
Collapse
Affiliation(s)
- Nicholas B Vera
- Pfizer Global Research and Development, Cambridge Laboratories, Pfizer Inc., Cambridge, MA, 02139, USA
- Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA
| | - Zhidan Chen
- Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA
| | - Evan Pannkuk
- Georgetown University, 3700 O Street NW, Washington, DC, 20057, USA
| | | | - Albert J Fornace
- Georgetown University, 3700 O Street NW, Washington, DC, 20057, USA
| | - Derek M Erion
- Pfizer Global Research and Development, Cambridge Laboratories, Pfizer Inc., Cambridge, MA, 02139, USA
| | - Stephen L Coy
- Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA
| | - Jeffrey A Pfefferkorn
- Pfizer Global Research and Development, Cambridge Laboratories, Pfizer Inc., Cambridge, MA, 02139, USA
| | - Paul Vouros
- Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA
| |
Collapse
|
20
|
Garabedian A, Leng F, Ridgeway ME, Park MA, Fernandez-Lima F. Tailoring peptide conformational space with organic gas modifiers in TIMS-MS. ACTA ACUST UNITED AC 2018. [DOI: 10.1007/s12127-018-0231-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
21
|
Pampanin DM, Brooks SJ, Grøsvik BE, Le Goff J, Meier S, Sydnes MO. DNA adducts in marine fish as biological marker of genotoxicity in environmental monitoring: The way forward. MARINE ENVIRONMENTAL RESEARCH 2017; 125:49-62. [PMID: 28167386 DOI: 10.1016/j.marenvres.2017.01.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Revised: 01/17/2017] [Accepted: 01/19/2017] [Indexed: 05/25/2023]
Abstract
DNA adducts in fish represent a very important genotoxicity endpoint in environmental monitoring, being a pre-mutagenic lesion that plays an essential role in the initiation of carcinogenesis. The analysis of DNA adducts is a challenging task due to the low concentration of the analyte. Methods are available to determine the presence of DNA adducts, although further knowledge is required to fully understand the nature of the adducts and responsible xenobiotics (i.e. position of adduct in DNA, most active xenobiotic and metabolite forms, structural information). At present, 32P-postlabeling is the most used method that has the required sensitivity for DNA adduct analyses in both human health and environmental monitoring. Development of new mass spectrometry based methods for identifying DNA adducts in complex matrixes is now considered as a necessary mission in toxicology in order to gain the necessary information regarding adduct formation and facilitate tracking sources of contamination. Mass spectrometry therefore represents the future of DNA adduct detection, bringing along a series of challenges that the scientific community is facing at present.
Collapse
Affiliation(s)
- Daniela M Pampanin
- International Research Institute of Stavanger, Mekjarvik 12, NO-4070 Randaberg, Norway; Faculty of Science and Technology, Department of Mathematics and Natural Science, University of Stavanger, NO-4036 Stavanger, Norway.
| | - Steven J Brooks
- Norwegian Institute for Water Research (NIVA), Gaustadalléen 21, NO-0349 Oslo, Norway
| | | | - Jérémie Le Goff
- ADn'tox, Bâtiment Recherche, Centre François Baclesse 3, Avenue du Général Harris, 14076 Caen Cedex 5, France
| | - Sonnich Meier
- Institute of Marine Research, Box 1870, Nordnes, NO-5817 Bergen, Norway
| | - Magne O Sydnes
- Faculty of Science and Technology, Department of Mathematics and Natural Science, University of Stavanger, NO-4036 Stavanger, Norway
| |
Collapse
|
22
|
Manolakos S, Sinatra F, Albers L, Hufford K, Alberti J, Nazarov E, Evans-Nguyen T. Differential Mobility Spectrometry for Inorganic Filtration in Nuclear Forensics. Anal Chem 2016; 88:11399-11405. [DOI: 10.1021/acs.analchem.6b01441] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Spiros Manolakos
- Draper Laboratory, 3802 Spectrum Boulevard,
Suite 201, Tampa, Florida 33612, United States
| | - Francy Sinatra
- Draper Laboratory, 3802 Spectrum Boulevard,
Suite 201, Tampa, Florida 33612, United States
| | - Leila Albers
- Draper Laboratory, 3802 Spectrum Boulevard,
Suite 201, Tampa, Florida 33612, United States
| | - Kevin Hufford
- Draper Laboratory, 3802 Spectrum Boulevard,
Suite 201, Tampa, Florida 33612, United States
| | - James Alberti
- Draper Laboratory, 3802 Spectrum Boulevard,
Suite 201, Tampa, Florida 33612, United States
| | - Erkinjon Nazarov
- Draper Laboratory, 3802 Spectrum Boulevard,
Suite 201, Tampa, Florida 33612, United States
| | - Theresa Evans-Nguyen
- Draper Laboratory, 3802 Spectrum Boulevard,
Suite 201, Tampa, Florida 33612, United States
- The University of South Florida, Department
of Chemistry, 4202 East
Fowler Avenue, CHE 205, Tampa, Florida 33620, United States
| |
Collapse
|
23
|
Chen Z, Coy SL, Pannkuk EL, Laiakis EC, Hall AB, Fornace AJ, Vouros P. Rapid and High-Throughput Detection and Quantitation of Radiation Biomarkers in Human and Nonhuman Primates by Differential Mobility Spectrometry-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:1626-36. [PMID: 27392730 PMCID: PMC5018447 DOI: 10.1007/s13361-016-1438-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2016] [Revised: 06/02/2016] [Accepted: 06/16/2016] [Indexed: 05/04/2023]
Abstract
Radiation exposure is an important public health issue due to a range of accidental and intentional threats. Prompt and effective large-scale screening and appropriate use of medical countermeasures (MCM) to mitigate radiation injury requires rapid methods for determining the radiation dose. In a number of studies, metabolomics has identified small-molecule biomarkers responding to the radiation dose. Differential mobility spectrometry-mass spectrometry (DMS-MS) has been used for similar compounds for high-throughput small-molecule detection and quantitation. In this study, we show that DMS-MS can detect and quantify two radiation biomarkers, trimethyl-L-lysine (TML) and hypoxanthine. Hypoxanthine is a human and nonhuman primate (NHP) radiation biomarker and metabolic intermediate, whereas TML is a radiation biomarker in humans but not in NHP, which is involved in carnitine synthesis. They have been analyzed by DMS-MS from urine samples after a simple strong cation exchange-solid phase extraction (SCX-SPE). The dramatic suppression of background and chemical noise provided by DMS-MS results in an approximately 10-fold reduction in time, including sample pretreatment time, compared with liquid chromatography-mass spectrometry (LC-MS). DMS-MS quantitation accuracy has been verified by validation testing for each biomarker. Human samples are not yet available, but for hypoxanthine, selected NHP urine samples (pre- and 7-d-post 10 Gy exposure) were analyzed, resulting in a mean change in concentration essentially identical to that obtained by LC-MS (fold-change 2.76 versus 2.59). These results confirm the potential of DMS-MS for field or clinical first-level rapid screening for radiation exposure. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Zhidan Chen
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA, 02115, USA
| | - Stephen L Coy
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA, 02115, USA.
| | - Evan L Pannkuk
- Department of Biochemistry and Molecular and Cellular Biology, Georgetown University Medical Center, Washington, DC, 20057, USA
| | - Evagelia C Laiakis
- Department of Biochemistry and Molecular and Cellular Biology, Georgetown University Medical Center, Washington, DC, 20057, USA
| | - Adam B Hall
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA, 02115, USA
| | - Albert J Fornace
- Department of Biochemistry and Molecular and Cellular Biology, Georgetown University Medical Center, Washington, DC, 20057, USA
- Lombardi Comprehensive Cancer Center, Georgetown University, Washington, DC, 20057, USA
- Center of Excellence in Genomic Medicine Research, King Abdulaziz University, Jeddah, 22254, Saudi Arabia
| | - Paul Vouros
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA, 02115, USA.
- Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, MA, 02115, USA.
| |
Collapse
|
24
|
Schneider BB, Nazarov EG, Londry F, Vouros P, Covey TR. Differential mobility spectrometry/mass spectrometry history, theory, design optimization, simulations, and applications. MASS SPECTROMETRY REVIEWS 2016; 35:687-737. [PMID: 25962527 DOI: 10.1002/mas.21453] [Citation(s) in RCA: 131] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2014] [Accepted: 11/26/2014] [Indexed: 05/28/2023]
Abstract
This review of differential mobility spectrometry focuses primarily on mass spectrometry coupling, starting with the history of the development of this technique in the Soviet Union. Fundamental principles of the separation process are covered, in addition to efforts related to design optimization and advancements in computer simulations. The flexibility of differential mobility spectrometry design features is explored in detail, particularly with regards to separation capability, speed, and ion transmission. 2015 Wiley Periodicals, Inc. Mass Spec Rev 35:687-737, 2016.
Collapse
Affiliation(s)
| | | | | | - Paul Vouros
- Department of Chemistry and Chemical Biology, Barnett Institute, Northeastern University, Boston, MA 02115
| | | |
Collapse
|
25
|
Waraksa E, Perycz U, Namieśnik J, Sillanpää M, Dymerski T, Wójtowicz M, Puton J. Dopants and gas modifiers in ion mobility spectrometry. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.06.009] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
26
|
Raeber AE, Wong BM. The Importance of Short- and Long-Range Exchange on Various Excited State Properties of DNA Monomers, Stacked Complexes, and Watson-Crick Pairs. J Chem Theory Comput 2016; 11:2199-209. [PMID: 26574420 DOI: 10.1021/acs.jctc.5b00105] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We present a detailed analysis of several time-dependent DFT (TD-DFT) methods, including conventional hybrid functionals and two types of nonempirically tuned range-separated functionals, for predicting a diverse set of electronic excitations in DNA nucleobase monomers and dimers. This large and extensive set of excitations comprises a total of 50 different transitions (for each tested DFT functional) that includes several n → π and π → π* valence excitations, long-range charge-transfer excitations, and extended Rydberg transitions (complete with benchmark calculations from high-level EOM-CCSD(T) methods). The presence of localized valence excitations as well as extreme long-range charge-transfer excitations in these systems poses a serious challenge for TD-DFT methods that allows us to assess the importance of both short- and long-range exchange contributions for simultaneously predicting all of these various transitions. In particular, we find that functionals that do not have both short- and full long-range exchange components are unable to predict the different types of nucleobase excitations with the same accuracy. Most importantly, the current study highlights the importance of both short-range exchange and a nonempirically tuned contribution of long-range exchange for accurately predicting the diverse excitations in these challenging nucleobase systems.
Collapse
Affiliation(s)
- Alexandra E Raeber
- Department of Chemical & Environmental Engineering and Materials Science & Engineering Program, University of California, Riverside , Riverside, California 92521, United States
| | - Bryan M Wong
- Department of Chemical & Environmental Engineering and Materials Science & Engineering Program, University of California, Riverside , Riverside, California 92521, United States
| |
Collapse
|
27
|
Zhu S, Campbell JL, Chernushevich I, Le Blanc JCY, Wilson DJ. Differential Mobility Spectrometry-Hydrogen Deuterium Exchange (DMS-HDX) as a Probe of Protein Conformation in Solution. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:991-999. [PMID: 26965162 DOI: 10.1007/s13361-016-1364-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 02/04/2016] [Accepted: 02/05/2016] [Indexed: 06/05/2023]
Abstract
Differential mobility spectrometry (DMS) is an ion mobility technique that has been adopted chiefly as a pre-filter for small- to medium-sized analytes (<1 000 Da). With the exception of a handful of studies that employ an analogue of DMS-field asymmetric waveform ion mobility spectroscopy (FAIMS)-the application of DMS to intact biomacromolecules remains largely unexplored. In this work, we employ DMS combined with gas-phase hydrogen deuterium exchange (DMS-HDX) to probe the gas-phase conformations generated from proteins that were initially folded, partially-folded, and unfolded in solution. Our findings indicate that proteins with distinct structural features in solution exhibit unique deuterium uptake profiles as function of their optimal transmission through the DMS. Ultimately we propose that DMS-HDX can, if properly implemented, provide rapid measurements of liquid-phase protein structural stability that could be of use in biopharmaceuticals development. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Shaolong Zhu
- Chemistry Department, York University, Toronto, ON, M3J 1P3, Canada
| | | | | | | | - Derek J Wilson
- Chemistry Department, York University, Toronto, ON, M3J 1P3, Canada.
- Center for Research in Mass Spectrometry, Department of Chemistry, York University, Toronto, ON, M3J 1P3, Canada.
| |
Collapse
|
28
|
Liu C, Le Blanc JCY, Shields J, Janiszewski JS, Ieritano C, Ye GF, Hawes GF, Hopkins WS, Campbell JL. Using differential mobility spectrometry to measure ion solvation: an examination of the roles of solvents and ionic structures in separating quinoline-based drugs. Analyst 2015; 140:6897-903. [DOI: 10.1039/c5an00842e] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Understanding the mechanisms and energetics of ion solvation using differential mobility spectrometry.
Collapse
Affiliation(s)
| | | | - Jefry Shields
- Groton lab
- Pfizer Global Research and Development
- Groton
- USA
| | | | | | - Gene F. Ye
- Department of Chemistry
- University of Waterloo
- Waterloo
- Canada
| | | | | | | |
Collapse
|
29
|
Auerbach D, Aspenleiter J, Volmer DA. Description of gas-phase ion/neutral interactions in differential ion mobility spectrometry: CV prediction using calibration runs. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:1610-1621. [PMID: 24927778 DOI: 10.1007/s13361-014-0934-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 05/12/2014] [Accepted: 05/12/2014] [Indexed: 06/03/2023]
Abstract
Differential ion mobility spectrometry (DMS) coupled to mass spectrometry is increasingly used in both quantitative analyses of biological samples and as a means of removing background interferences for enhanced selectivity and improved quality of mass spectra. However, DMS separation efficiency using dry inert gases often lacks the required selectivity to achieve baseline separation. Polar gas-phase modifiers such as alcohols are therefore frequently employed to improve selectivity via clustering/declustering processes. The choice of an optimal modifier currently relies on trial and error experiments, making method development a tedious activity. It was the goal of this study to establish a means of CV prediction for compounds using a homologous series of alcohols as gas-phase modifiers. This prediction was based on linear regression of compensation voltages of two calibration runs for the alcohols with the lowest and the highest molecular weights and readily available descriptors such as proton affinity and gas phase acidity of the modifier molecules. All experiments were performed on a commercial quadrupole linear ion trap mass spectrometer equipped with a DMS device between electrospray ionization source and entrance quadrupole lens. We evaluated our approach using a homologous series of 4-alkylbenzoic acids and a selection of 23 small molecules of high chemical diversity. Predicted CV values typically deviated from the experimentally determined values by less than 0.5 V. Several test compounds changed their ion mobility behavior for the investigated gas phase modifiers (e.g., from type B to type A) and thus could thus not be evaluated.
Collapse
Affiliation(s)
- David Auerbach
- Institute of Bioanalytical Chemistry, Saarland University, Saarbrücken, Germany
| | | | | |
Collapse
|
30
|
Campbell JL, Zhu M, Hopkins WS. Ion-molecule clustering in differential mobility spectrometry: lessons learned from tetraalkylammonium cations and their isomers. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:1583-1591. [PMID: 25001379 DOI: 10.1007/s13361-014-0939-3] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Revised: 05/28/2014] [Accepted: 05/30/2014] [Indexed: 06/03/2023]
Abstract
Differential mobility spectrometry (DMS) can distinguish ions based upon the differences in their high- and low-field ion mobilities as they experience the asymmetric waveform applied to the DMS cell. These mobilities are known to be influenced by the ions' structure, m/z, and charge distribution (i.e., resonance structures) within the ions themselves, as well as by the gas-phase environment of the DMS cell. While these associations have been developed over time through empirical observations, the exact role of ion structures or their interactions with clustering molecules remains generally unknown. In this study, that relationship is explored by observing the DMS behaviors of a series of tetraalkylammonium ions as a function of their structures and the gas-phase environment of the DMS cell. To support the DMS experiments, the basin-hopping search strategy was employed to identify candidate cluster structures for density functional theory treatment. More than a million cluster structures distributed across 72 different ion-molecule cluster systems were sampled to determine global minimum structures and cluster binding energies. This joint computational and experimental approach suggests that cluster geometry, in particular ion-molecule intermolecular separation, plays a critical role in DMS.
Collapse
|