1
|
Chen T, Sun C, Abbas SC, Alam N, Qiang S, Tian X, Fu C, Zhang H, Xia Y, Liu L, Ni Y, Jiang X. Multi-dimensional microfluidic paper-based analytical devices (μPADs) for noninvasive testing: A review of structural design and applications. Anal Chim Acta 2024; 1321:342877. [PMID: 39155092 DOI: 10.1016/j.aca.2024.342877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 06/13/2024] [Accepted: 06/14/2024] [Indexed: 08/20/2024]
Abstract
The rapid emergence of microfluidic paper-based devices as point-of-care testing (POCT) tools for early disease diagnosis and health monitoring, particularly in resource-limited areas, holds immense potential for enhancing healthcare accessibility. Leveraging the numerous advantages of paper, such as capillary-driven flow, porous structure, hydrophilic functional groups, biodegradability, cost-effectiveness, and flexibility, it has become a pivotal choice for microfluidic substrates. The repertoire of microfluidic paper-based devices includes one-dimensional lateral flow assays (1D LFAs), two-dimensional microfluidic paper-based analytical devices (2D μPADs), and three-dimensional (3D) μPADs. In this comprehensive review, we provide and examine crucial information related to paper substrates, design strategies, and detection methods in multi-dimensional microfluidic paper-based devices. We also investigate potential applications of microfluidic paper-based devices for detecting viruses, metabolites and hormones in non-invasive samples such as human saliva, sweat and urine. Additionally, we delve into capillary-driven flow alternative theoretical models of fluids within the paper to provide guidance. Finally, we critically examine the potential for future developments and address challenges for multi-dimensional microfluidic paper-based devices in advancing noninvasive early diagnosis and health monitoring. This article showcases their transformative impact on healthcare, paving the way for enhanced medical services worldwide.
Collapse
Affiliation(s)
- Ting Chen
- College of Bioresources Chemical and Materials Engineering, Shaanxi Province Key Laboratory of Papermaking Technology and Specialty Paper Development, Shaanxi University of Science & Technology, Xi'an, Shaanxi, 710021, China; Limerick Pulp & Paper Centre & Department of Chemical Engineering, University of New Brunswick, Fredericton, NB, E3B 5A3, Canada
| | - Ce Sun
- College of Bioresources Chemical and Materials Engineering, Shaanxi Province Key Laboratory of Papermaking Technology and Specialty Paper Development, Shaanxi University of Science & Technology, Xi'an, Shaanxi, 710021, China
| | - Syed Comail Abbas
- Limerick Pulp & Paper Centre & Department of Chemical Engineering, University of New Brunswick, Fredericton, NB, E3B 5A3, Canada; Department of Chemical and Biomedical Engineering, University of Maine, Orono, ME, USA
| | - Nur Alam
- Limerick Pulp & Paper Centre & Department of Chemical Engineering, University of New Brunswick, Fredericton, NB, E3B 5A3, Canada
| | - Sheng Qiang
- College of Bioresources Chemical and Materials Engineering, Shaanxi Province Key Laboratory of Papermaking Technology and Specialty Paper Development, Shaanxi University of Science & Technology, Xi'an, Shaanxi, 710021, China
| | - Xiuzhi Tian
- College of Bioresources Chemical and Materials Engineering, Shaanxi Province Key Laboratory of Papermaking Technology and Specialty Paper Development, Shaanxi University of Science & Technology, Xi'an, Shaanxi, 710021, China
| | - Chenglong Fu
- Limerick Pulp & Paper Centre & Department of Chemical Engineering, University of New Brunswick, Fredericton, NB, E3B 5A3, Canada
| | - Hui Zhang
- College of Bioresources Chemical and Materials Engineering, Shaanxi Province Key Laboratory of Papermaking Technology and Specialty Paper Development, Shaanxi University of Science & Technology, Xi'an, Shaanxi, 710021, China; Limerick Pulp & Paper Centre & Department of Chemical Engineering, University of New Brunswick, Fredericton, NB, E3B 5A3, Canada
| | - Yuanyuan Xia
- College of Bioresources Chemical and Materials Engineering, Shaanxi Province Key Laboratory of Papermaking Technology and Specialty Paper Development, Shaanxi University of Science & Technology, Xi'an, Shaanxi, 710021, China; Limerick Pulp & Paper Centre & Department of Chemical Engineering, University of New Brunswick, Fredericton, NB, E3B 5A3, Canada
| | - Liu Liu
- College of Bioresources Chemical and Materials Engineering, Shaanxi Province Key Laboratory of Papermaking Technology and Specialty Paper Development, Shaanxi University of Science & Technology, Xi'an, Shaanxi, 710021, China
| | - Yonghao Ni
- Limerick Pulp & Paper Centre & Department of Chemical Engineering, University of New Brunswick, Fredericton, NB, E3B 5A3, Canada; Department of Chemical and Biomedical Engineering, University of Maine, Orono, ME, USA.
| | - Xue Jiang
- College of Bioresources Chemical and Materials Engineering, Shaanxi Province Key Laboratory of Papermaking Technology and Specialty Paper Development, Shaanxi University of Science & Technology, Xi'an, Shaanxi, 710021, China.
| |
Collapse
|
2
|
Sathishkumar N, Toley BJ. Paper-microfluidic signal-enhanced immunoassays. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:267-288. [PMID: 35033288 DOI: 10.1016/bs.pmbts.2021.07.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Over the past decade, paper-based microfluidic devices have become popular for their simplicity and ability to conduct diagnostic tests at a low cost. An important class of diagnostic assays that paper-based analytical devices have been used for is immunoassays. The lateral flow immunoassay (LFIA), of which the home pregnancy test is the most prominent example, has been one of the most commercially successful membrane-based diagnostic tests. Yet, the analytical sensitivity of LFIAs is lower than the corresponding laboratory technique called ELISA (enzyme-linked immunoassay). As a consequence, traditional LFIAs fail to deliver on the promise of bedside diagnostic testing for many applications. Recognizing this shortcoming, several new developments have been made by researchers to enhance the sensitivity of membrane-based immunoassays. In this chapter, we present the various strategies that have been employed to this end. In the end, we present a brief SWOT analysis to guide future work in this area.
Collapse
Affiliation(s)
- N Sathishkumar
- Department of Chemical Engineering, Indian Institute of Science, Bengaluru, KA, India
| | - Bhushan J Toley
- Department of Chemical Engineering, Indian Institute of Science, Bengaluru, KA, India.
| |
Collapse
|
3
|
Sinha A, Basu M, Chandna P. Paper based microfluidics: A forecast toward the most affordable and rapid point-of-care devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:109-158. [PMID: 35033281 DOI: 10.1016/bs.pmbts.2021.07.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The microfluidic industry has evolved through years with acquired scientific knowledge from different, and already developed industries. Consequently, a wide range of materials like silicon from the electronic industry to all the way, silicone, from the chemical engineering industry, has been spotted to solve similar challenges. Although a typical microfluidic chip, fabricated from glass or polymer substrates offers definite benefits, however, paper-based microfluidic analytical devices (μPADs) possess numerous special benefits for practical implementation at a lower price. Owing to these features, in recent years, paper microfluidics has drawn immense interest from researchers in industry and academia alike. These devices have wider applications with advantages like lower cost, speedy detection, user-easiness, biocompatibility, sensitivity, and specificity etc. when compared to other microfluidic devices. Therefore, these sensitive but affordable devices fit themselves into point-of-care (POC) testing with features in demand like natural disposability, situational flexibility, and the capability to store and analyze the target at the point of requirement. Gradually, advancements in fabrication technologies, assay development techniques, and improved packaging capabilities, have contributed significantly to the real-time identification and health investigation through paper microfluidics; however, the growth has not been limited to the biomedical field; industries like electronics, energy storage and many more have expanded substantially. Here, we represent an overall state of the paper-based microfluidic technology by covering the fundamentals, working principles, different fabrication procedures, applications for various needs and then to make things more practical, the real-life scenario and practical challenges involved in launching a device into the market have been revealed. To conclude, recent contribution of μPADs in the 2020 pandemic and potential future possibilities have been reviewed.
Collapse
|
4
|
Rath D, Toley BJ. Modeling-Guided Design of Paper Microfluidic Networks: A Case Study of Sequential Fluid Delivery. ACS Sens 2021; 6:91-99. [PMID: 33382580 DOI: 10.1021/acssensors.0c01840] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Paper-based microfluidic devices are popular for their ability to automate multistep assays for chemical or biological sensing at a low cost, but the design of paper microfluidic networks has largely relied on experimental trial and error. A few mathematical models of flow through paper microfluidic devices have been developed and have succeeded in explaining experimental flow behavior. However, the reverse engineering problem of designing complex paper networks guided by appropriate mathematical models is largely unsolved. In this article, we demonstrate that a two-dimensional paper network (2DPN) designed to sequentially deliver three fluids to a test zone on the device can be computationally designed and experimentally implemented without experimental trial and error. This was accomplished by three new developments in modeling flow through paper networks: (i) coupling of the Richards equation of flow through porous media to the species transport equation, (ii) modeling flow through assemblies of multiple paper materials (test membrane and wicking pad), and (iii) incorporating limited-volume fluid sources. We demonstrate the application of this model in the optimal design of a paper-based signal-enhanced immunoassay for a malaria protein, PfHRP2. This work lays the foundation for the development of a computational design toolbox to aid in the design of paper microfluidic networks.
Collapse
Affiliation(s)
- Dharitri Rath
- Department of Chemical Engineering, Indian Institute of Science, C V Raman Avenue, Bengaluru, Karnataka 560012, India
| | - Bhushan J. Toley
- Department of Chemical Engineering, Indian Institute of Science, C V Raman Avenue, Bengaluru, Karnataka 560012, India
| |
Collapse
|
5
|
Paper Stacks for Uniform Rehydration of Dried Reagents in Paper Microfluidic Devices. Sci Rep 2019; 9:15755. [PMID: 31673060 PMCID: PMC6823543 DOI: 10.1038/s41598-019-52202-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Accepted: 10/15/2019] [Indexed: 01/05/2023] Open
Abstract
Spatially uniform reconstitution of dried reagents is critical to the function of paper microfluidic devices. Advancing fluid fronts in paper microfluidic devices drive (convect) and concentrate rehydrated reagents to the edges, causing steep chemical gradients and imperfect mixing. This largely unsolved problem in paper microfluidics is exacerbated by increasing device dimensions. In this article, we demonstrate that mixing of dried reagents with a rehydrating fluid in paper microfluidics may be significantly enhanced by stacking paper layers having different wicking rates. Compared to single-layer paper membranes, stacking reduced the “non-reactive area”, i.e. area in which the reconstituted reagents did not interact with the rehydrating fluid, by as much as 97% in large (8 cm × 2 cm) paper membranes. A paper stack was designed to collect ~0.9 ml liquid sample and uniformly mix it with dried reagents. Applications of this technology are demonstrated in two areas: (i) collection and dry storage of sputum samples for tuberculosis testing, and (ii) salivary glucose detection using an enzymatic assay and colorimetric readout. Maximizing the interaction of liquids with dried reagents is central to enhancing the performance of all paper microfluidic devices; this technique is therefore likely to find important applications in paper microfluidics.
Collapse
|