1
|
Arya A, Haghjoo M, Sadr-Ameli MA. Can Amiodarone Prevent Sudden Cardiac Death in Patients with Hemodynamically Tolerated Sustained Ventricular Tachycardia and Coronary Artery Disease? Cardiovasc Drugs Ther 2005; 19:219-26. [PMID: 16142600 DOI: 10.1007/s10557-005-2502-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
One of the most important challenges in today's cardiology is prevention of sudden cardiac death in high risk patients with coronary artery disease (CAD). Sustained hemodynamically tolerated ventricular tachycardia (HTVT) comprises up to 30% of all cases of monomorphic ventricular tachycardia in patients with CAD. While there is a consensus on treatment of hemodynamically unstable sustained ventricular tachycardia in patients with CAD, some controversies regarding the proper treatment of HTVT exist. We re-examined existing clinical evidence, controversies and current guidelines on the treatment of HTVT in patients with CAD and demonstrated that compared to implantable cardioverter-defibrillator, amiodarone is not an acceptable therapeutic option in patients with ischemic heart disease who suffer from HTVT.
Collapse
Affiliation(s)
- Arash Arya
- Department of Pacemaker and Electrophysiology, Rajaie Cardiovascular Medical Center, Mellat Park, Vali-Asr Avenue, Tehran 1996911151, Iran.
| | | | | |
Collapse
|
2
|
Schläpfer J, Rapp F, Kappenberger L, Fromer M. Electrophysiologically guided amiodarone therapy versus the implantable cardioverter-defibrillator for sustained ventricular tachyarrhythmias after myocardial infarction: results of long-term follow-up. J Am Coll Cardiol 2002; 39:1813-9. [PMID: 12039497 DOI: 10.1016/s0735-1097(02)01863-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVES We sought to compare the long-term survival rates of patients with sustained ventricular tachyarrhythmia after myocardial infarction (MI) who were treated according to the results of electrophysiological (EP) study either with amiodarone or an implantable cardioverter-defibrillator (ICD). BACKGROUND Patients with sustained ventricular tachyarrhythmias after MI are at high risk of sudden cardiac death (SCD). However, data comparing the long-term survival rates of patients treated with amiodarone or ICD, according to the results of EP testing, are lacking. METHODS Patients underwent a first EP study at baseline and a second one after a loading dose of amiodarone of 14 +/- 2.9 g. According to the results of the second EP study, patients were classified either as responders or non-responders to amiodarone; non-responders were eventually treated with an ICD. RESULTS Eighty-four consecutive patients with MI (78 men; 21-77 years old; mean left ventricular (LV) ejection fraction 36 +/- 11%) were consecutively included. Forty-three patients (51%) were responders, and 41 patients (49%) were non-responders to amiodarone therapy. During a mean follow-up period of 63 +/- 30 months, SCD and total mortality rates were significantly higher in the amiodarone-treated patients (p = 0.03 and 0.02, respectively). CONCLUSIONS The long-term survival of patients with sustained ventricular tachyarrhythmias after MI, with depressed LV function, is significantly better with an ICD than with amiodarone therapy, even when stratified according to the results of the EP study. These patients should benefit from early ICD placement, and any previous amiodarone treatment seems to have no additional value.
Collapse
Affiliation(s)
- Jürg Schläpfer
- Division of Cardiology, University Hospital (CHUV), 1011 Lausanne, Switzerland.
| | | | | | | |
Collapse
|
3
|
Maury P, Zimmermann M, Metzger J, Reynard C, Dorsaz P, Adamec R. Amiodarone therapy for sustained ventricular tachycardia after myocardial infarction: long-term follow-up, risk assessment and predictive value of programmed ventricular stimulation. Int J Cardiol 2000; 76:199-210. [PMID: 11104875 DOI: 10.1016/s0167-5273(00)00379-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We determine the value of the programmed ventricular stimulation (PVS) and of clinical, angiographic and electrophysiologic variables in assessing the long-term risk of arrhythmia recurrence in a group of coronary artery diseased patients presenting with a first episode of monomorphic sustained ventricular tachycardia (VT) treated with amiodarone. Mortality and arrhythmia recurrence rates were retrospectively assessed in 55 consecutive patients with previous myocardial infarction presenting with a first VT episode. Results of left heart catheterization, echocardiography and time-domain signal-averaging were collected. Patients underwent PVS after amiodarone oral loading and were classified according to inducibility before being all discharged on amiodarone (200 mg daily). The mean follow-up was 42+/-31 months. Total and cardiac mortality rates were 29% (16 patients) and 23% (13 patients) respectively. Sudden death (SD) occurred in nine patients (16%). VT recurred in 13 patients (23%). Sustained monomorphic VT was inducible in 40 patients (72%) after amiodarone loading. Neither total mortality (10/40 vs. 6/15) nor cardiac mortality (3/40 vs. 1/15) were significantly different between inducible and non-inducible patients. Recurrent VT rate was 27% (11/40 patients) for the inducible group and 13% (2/15 patients) for the non-inducible group (NS). SD occurred in 6/40 inducible patients (15%) and in 2/15 non-inducible patients (13%) (NS). Arrhythmic events occurred in 42% (17/40) inducible patients vs. 26% (4/15) non-inducible patients (P=0.07). Parameters correlated with outcome were ejection fraction (EF) (5 SD/11 patients with EF <0.3 vs. 4/44 with EF >0.3, P=0.003), mitral insufficiency (MI) (4 SD/10 patients with MI vs. 4/44 patients without MI, P=0.004) and age (65+/-9 years for patients with VT recurrence vs. 58+/-9, P=0.02). Although the risk stratification can be improved, reliable and safe long-term prediction of recurrence of malignant ventricular arrhythmia in individual patients cannot be made. Consequently, the systematic implantation of a cardioverter-defibrillator in case of a first episode of sustained VT occurring in coronary artery disease patients should be further debated.
Collapse
Affiliation(s)
- P Maury
- Division of Cardiology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | | | | | | | | | | |
Collapse
|
4
|
Abstract
This article provides a review of the risks faced by patients with sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) in the absence of a reversible or transient cause so that the goals of therapy can be clearly defined. The therapeutic approaches that have been proposed to achieve these goals are outlined and evidence comparing these various approaches to therapy is then summarized in order to propose an algorithm for the optimal use of antiarrhythmic drug therapies as primary therapy for selected VT/VF patients. Options for the ancillary uses of antiarrhythmic drug therapies in ICD patients are considered.
Collapse
Affiliation(s)
- L B Mitchell
- Division of Cardiology, University of Calgary, Alberta, Canada
| |
Collapse
|
5
|
Haverkamp W, Eckardt L, Borggrefe M, Breithardt G. Drugs versus devices in controlling ventricular tachycardia, ventricular fibrillation, and recurrent cardiac arrest. Am J Cardiol 1997; 80:67G-73G. [PMID: 9354413 DOI: 10.1016/s0002-9149(97)00715-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Patients with symptomatic ventricular tachycardia, ventricular fibrillation, or aborted sudden cardiac death remain at high risk for arrhythmia recurrence. In recent years, strategies to treat these patients have changed. Concerns about the proarrhythmia risk and uncertain efficacy of class I agents have resulted in a shift in interest to non-class I antiarrhythmic drugs such as sotalol and amiodarone. Both drugs have class III antiarrhythmic properties (i.e., both lengthen repolarization and refractoriness); however, each also has its own additional electrophysiologic effects. Prospectively designed, randomized studies have shown that both sotalol and amiodarone have more potent antiarrhythmic actions than class I agents. However, even as the advantages of sotalol and amiodarone have been recognized, enthusiasm for nonpharmacologic modes of treatment, particularly the implantable cardioverter-defibrillator (ICD), has also markedly increased. The ICD has been shown to decrease dramatically the incidence of sudden death, which may lead to the reduction of total mortality. Whether patients with life-threatening ventricular tachyarrhythmias should be treated first with antiarrhythmic agents or with an ICD is an important question. The results of recent studies suggest that treatment with an ICD is more effective than electrophysiologically guided treatment with class I agents. However, results of prospectively designed randomized studies comparing the efficacy of the ICD with that of sotalol and amiodarone must become available before definitive recommendations can be made concerning the use of the ICD as first-line therapy in patients with ventricular tachycardia/ventricular fibrillation or aborted sudden cardiac death. In addition, there may be a significant role for the use of antiarrhythmic drugs in conjunction with ICDs.
Collapse
Affiliation(s)
- W Haverkamp
- Department of Cardiology and Angiology and Institute for Arteriosclerosis Research, WestfâlischeWilhelms-University, Münster, Germany
| | | | | | | |
Collapse
|
6
|
Kupersmith J, Holmes-Rovner M, Hogan A, Rovner D, Gardiner J. Cost-effectiveness analysis in heart disease, Part III: Ischemia, congestive heart failure, and arrhythmias. Prog Cardiovasc Dis 1995; 37:307-46. [PMID: 7871179 DOI: 10.1016/s0033-0620(05)80017-9] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Cost-effectiveness analyses were reviewed in the following diagnostic and treatment categories: acute myocardial infarction (MI) and diagnostic strategies for coronary artery disease (CAD), coronary artery bypass graft (CABG) surgery, percutaneous transluminal coronary angioplasty (PTCA), congestive heart failure (CHF), and arrhythmias. In the case of acute MI, coronary care units, as presently used, are rather expensive but could be made much more efficient with more effective triage and resource utilization; reperfusion via thrombolysis is cost-effective, as are beta-blockers and angiotensin-converting enzyme (ACE) inhibitors post-MI in appropriate patients. Cost-effectiveness of CAD screening tests depends strongly on the prevalence of disease in the population studied. Cost-effectiveness of CABG surgery depends on targeting; eg, it is highly effective for such conditions as left-main and three-vessel disease but not for lesser disease. PTCA appears to be cost-effective in situations where there is clinical consensus for its use, eg, severe ischemia and one-vessel disease, but requires further analysis based on randomized data; coronary stents also appear to be cost-effective. In preliminary analysis, ACE inhibition for CHF dominates, ie, saves both money and lives. Cardiac transplant appears to be cost-effective but requires further study. For arrhythmias, implantable cardioverter defibrillators are cost-effective, especially the transvenous device, in life-threatening situations; radiofrequency ablation is also cost-effective in patients with Wolff-Parkinson-White syndrome apart from asymptomatic individuals; and pacemakers have not been analyzed except in the case of biofascicular block, where results were variable depending on the situation and preceding tests.
Collapse
Affiliation(s)
- J Kupersmith
- Department of Medicine, College of Human Medicine, Michigan State University, East Lansing 48824
| | | | | | | | | |
Collapse
|
7
|
Man KC, Williamson BD, Niebauer M, Daoud E, Bakr O, Strickberger SA, Hummel JD, Kou W, Morady F. Electrophysiologic effects of sotalol and amiodarone in patients with sustained monomorphic ventricular tachycardia. Am J Cardiol 1994; 74:1119-23. [PMID: 7977070 DOI: 10.1016/0002-9149(94)90463-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
No prospective studies have compared sotalol and amiodarone during electropharmacologic testing. The purpose of this prospective, randomized study was to compare the electrophysiologic effects of sotalol and amiodarone in patients with coronary artery disease and sustained monomorphic ventricular tachycardia (VT). Patients with coronary artery disease and sustained monomorphic VT inducible by programmed stimulation were randomly assigned to receive either sotalol (n = 17) or amiodarone (n = 17). The sotalol dose was titrated to 240 mg twice daily over 7 days. Amiodarone dosing consisted of 600 mg 3 times daily for 10 days. An electrophysiologic test was performed in the baseline state and at the end of the loading regimen. An adequate response was defined as the inability to induce VT or the ability to induce only relatively slow hemodynamically stable VT. During the follow-up electrophysiologic test, 24% of patients taking sotalol and 41% of those taking amiodarone had an adequate response to therapy (p = 0.30). Amiodarone lengthened the mean VT cycle length to a greater degree than sotalol (28% vs 12%, p < 0.01). There were no significant differences in the effects of sotalol and amiodarone on the ventricular effective refractory period. In patients with coronary artery disease, amiodarone and sotalol are similar in efficacy in the treatment of VT as assessed by electropharmacologic testing. The effects of the 2 drugs on ventricular refractoriness are similar, but amiodarone slows VT to a greater extent than sotalol.
Collapse
Affiliation(s)
- K C Man
- Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor 48109-0022
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Roberts SA, Viana MA, Nazari J, Bauman JL. Invasive and noninvasive methods to predict the long-term efficacy of amiodarone: a compilation of clinical observations using meta-analysis. Pacing Clin Electrophysiol 1994; 17:1590-602. [PMID: 7800560 DOI: 10.1111/j.1540-8159.1994.tb02352.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
BACKGROUND The method of choice to predict the long-term efficacy of amiodarone in the treatment of complex ventricular arrhythmias is unknown. Whether electrophysiological testing or Holter monitoring better predicts long-term outcome is controversial. METHODS AND RESULTS We performed a meta-analysis of trials using electrophysiological testing or electrocardiographic monitoring to predict the efficacy of amiodarone in patients with sustained ventricular tachycardia. Arrhythmia recurrence data were combined after homogeneity testing across trials. Bayesian estimates and 95% credibility intervals were constructed to compare the arrhythmia-free probability among groups. Nine studies using electrophysiological testing (351 patients) and three using Holter monitoring (167 patients) met criteria for inclusion determined a priori. The combined arrhythmia-free probability estimate and credibility intervals were 0.86 (0.78-0.92) for patients rendered noninducible and 0.81 (0.73-0.87) for patients with abolition of ventricular tachycardia during Holter monitoring on amiodarone. With this primary analysis, there was no significant difference between the predictive value of noninducibility during electrophysiological testing and abolition of ventricular tachycardia with Holter. However, if only those electrophysiological studies using at least triple extrastimuli were included, arrhythmia-free probability for patients rendered noninducible increased to 0.96 (0.88-0.99), significantly better than noninvasive testing. CONCLUSIONS Noninducible ventricular tachycardia during electrophysiological testing and abolition of ventricular tachycardia during electrocardiographic monitoring on amiodarone appear equally predictive of long-term amiodarone success, but this conclusion seems dependent on the stimulation protocol used. Although the yield is lower (compared to Holter monitoring), ventricular tachycardia rendered noninducible with a stimulation protocol using triple extrastimuli is the most highly predictive test of long-term amiodarone efficacy.
Collapse
Affiliation(s)
- S A Roberts
- Department of Pharmacy Practice, School of Public Health, University of Illinois at Chicago 60612
| | | | | | | |
Collapse
|
9
|
Martínez-Rubio A, Shenasa M, Chen X, Wichter T, Breithardt G, Borggrefe M. Response to sotalol predicts the response to amiodarone during serial drug testing in patients with sustained ventricular tachycardia and coronary artery disease. Am J Cardiol 1994; 73:357-60. [PMID: 7509121 DOI: 10.1016/0002-9149(94)90008-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
UNLABELLED It was analyzed whether the response to sotalol can predict the response to amiodarone as evaluated by programmed ventricular stimulation in 30 patients with coronary artery disease and documented recurrent sustained ventricular tachycardia (VT). Programmed ventricular stimulation was performed using 1 or 2 extrastimuli during sinus rhythm and 4 drive cycle lengths at 2 right ventricular sites. If no ventricular tachyarrhythmia was induced, a third extrastimulus was introduced during a paced cycle length of 500 ms. During the control study, VT (mean cycle length 305 +/- 63 ms) was induced in all patients, and the right ventricular effective refractory period (during S1-S1 = 500 ms) was 223 +/- 12 ms. After sotalol, sustained and nonsustained VT were inducible in 22 (73%) and 7 (23%) patients, respectively. One patient did not undergo stimulation on sotalol, because of side effects. After amiodarone, sustained and nonsustained VT were inducible in 23 (77%) and 7 (23%) patients, respectively. The mean cycle length of the induced VT was prolonged after both drugs by 17% (p < 0.001). The effective refractory period was prolonged by 15% (p < 0.001) after sotalol and by 13% (p < 0.001 compared with baseline study; p = NS between both drugs) after amiodarone. Thus, concordant results (effective or ineffective drug) between sotalol and amiodarone were found in 26 patients (87%). IN CONCLUSION (1) The effects of sotalol and amiodarone on the cycle length of induced VT and on right ventricular effective refractory period were similar; and (2) inability to suppress VT by amiodarone can be predicted from the response to sotalol.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- A Martínez-Rubio
- Department of Cardiology and Angiology, University of Münster, Germany
| | | | | | | | | | | |
Collapse
|
10
|
Kalbfleisch SJ, Williamson B, Man KC, Vorperian V, Hummel JD, Hasse C, Strickberger SA, Calkins H, Langberg JJ, Morady F. Prospective, randomized comparison of conventional and high dose loading regimens of amiodarone in the treatment of ventricular tachycardia. J Am Coll Cardiol 1993; 22:1723-9. [PMID: 8227846 DOI: 10.1016/0735-1097(93)90603-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVES The purpose of this prospective randomized study was to compare the electrophysiologic effects of conventional and high dose loading regimens of amiodarone in patients with sustained ventricular tachycardia. BACKGROUND Uncontrolled studies in which patients have been treated with an oral loading dose of 2 to 4 g/day of amiodarone have suggested that, compared with a conventional loading dose, this dosing regimen results in more rapid control of spontaneous ventricular tachycardia and ventricular tachycardia induced by programmed stimulation. METHODS Patients in whom sustained monomorphic ventricular tachycardia was inducible by programmed stimulation and who were refractory to class I antiarrhythmic medications were randomly assigned to receive either a conventional (n = 15) or a high (n = 17) loading dose of amiodarone. The conventional dose consisted of 600 mg twice a day for 10 days. The high dose regimen consisted of 50 mg/kg body weight per day on days 1 to 3, 30 mg/kg per day on days 4 and 5 and 600 mg twice a day on days 6 to 10. An electrophysiologic test was performed in the baseline state and after 3 and 10 days of therapy. An adequate response to amiodarone was defined as the inability to induce ventricular tachycardia or the ability to induce only relatively slow (cycle length > or = 350 ms) hemodynamically stable ventricular tachycardia. RESULTS After 3 days of therapy, 2 of 14 patients who received the conventional loading dose and 6 of 15 patients who received the high dose loading regimen had an adequate response to amiodarone (p = 0.08). After 10 days of therapy, four patients in each group had an adequate response to amiodarone (p = NS). Three patients who received the high dose and one patient who received the conventional dose of amiodarone had an adequate response after 3 days of therapy but not after 10 days of therapy. There were significant increases in the sinus cycle length, atrioventricular block cycle length, ventricular effective refractory period and ventricular tachycardia cycle length after 3 and 10 days of therapy compared with baseline values regardless of the dosing regimen. The extent of the effects of amiodarone on these variables after 3 and 10 days of therapy was similar with both dosing regimens. CONCLUSIONS The therapeutic and electrophysiologic effects of conventional and high dose loading regimens of amiodarone do not differ significantly after 3 or 10 days of therapy. High oral loading doses of amiodarone do not offer any significant clinical advantage over a conventional loading dose of amiodarone for controlling ventricular tachycardia induced by programmed stimulation.
Collapse
Affiliation(s)
- S J Kalbfleisch
- Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Proclemer A, Facchin D, Vanuzzo D, Feruglio GA. Risk stratification and prognosis of patients treated with amiodarone for malignant ventricular tachyarrhythmias after myocardial infarction. Cardiovasc Drugs Ther 1993; 7:683-9. [PMID: 8241012 DOI: 10.1007/bf00877822] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Seventy-seven consecutive patients (mean age 62 years) with episodes of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) after acute myocardial infarction (AMI) were evaluated to assess the long-term efficacy of first-line amiodarone treatment and to identify clinical and laboratory factors associated with a high risk of death or arrhythmia recurrence. The presenting arrhythmia was VT in 41 cases (53%) and VF in 36 (47%). VT or VF occurred between the 4th and 90th day after AMI in 45 cases (58%) and later (more than 90 days) in the remaining 32 (42%). The mean number of arrhythmic episodes was 4.2. Forty patients (52%) were in New York Heart Association (NYHA) class I or II, and 37 (48%) were in class III or IV. Mean left ventricular ejection fraction was 32%; ventricular aneurysm was present in 41 subjects. Most patients had multivessel coronary artery disease. Amiodarone was administered as a first-choice drug in all patients, in combination with other antiarrhythmic drugs in 14. By ventricular stimulation after loading doses of amiodarone, sustained VT was inducible in 46 (62%) and noninducible in 28 (38%). During a mean follow-up of 28 months the incidence of cardiac mortality at 1, 3, and 5 years was 21%, 37%, and 47%; of sudden death was 7%, 19%, and 23%; of nonfatal VT recurrence was 13%, 13%, and 24%, respectively. The overall incidence of amiodarone side effects was 35%.2+ was a weak predictor only by univariate analysis (p = 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- A Proclemer
- Istituto di Cardiologia, Ospedale S.M. della Misericordia, Udine, Italy
| | | | | | | |
Collapse
|
12
|
Kowey PR, Marinchak RA, Rials SJ, Rubin AM, Smith L. Electrophysiologic testing in patients who respond acutely to intravenous amiodarone for incessant ventricular tachyarrhythmias. Am Heart J 1993; 125:1628-32. [PMID: 8498304 DOI: 10.1016/0002-8703(93)90751-t] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The outcome of patients who receive intravenous amiodarone for suppression of incessant ventricular tachyarrhythmia has not been studied conclusively. We conducted a prospective study in which all patients who responded acutely to intravenous amiodarone and went on to receive a subsequent oral loading dose were subjected to electrophysiologic testing before hospital discharge to determine whether additional or alternative therapy would be required. Among 18 patients (17 with ischemic heart disease) who entered the protocol, 16 had a clinical response to intravenous amiodarone alone (12 patients) or in combination with another antiarrhythmic drug (4 patients) and survived to study. Of these, 10 had monomorphic ventricular tachycardia (VT) when first seen, five had polymorphous VT or ventricular fibrillation (VF), and three had both. In seven patients sustained monomorphic VT was inducible (group 1), and in nine it was not (group 2). The only clinical factor that distinguished group 1 from group 2 was age (group 1 > group 2). Five patients in group 1 and one in group 2 received an implantable cardioverter defibrillator; one patient in group 1 had a successful endocardial resection. During a mean follow-up period of 11 months, four patients in group 1 have had appropriate implantable cardioverter defibrillator discharges, whereas only one patient in group 2 has had a clinical event (sudden death). We conclude that intravenous amiodarone is a highly effective drug used alone or in combination to suppress spontaneous incessant VT/VF. Predischarge electrophysiologic testing, even in patients who have polymorphous VT, has predictive value over and above the observed clinical response. These preliminary results favor predischarge testing and aggressive device treatment in this cohort.
Collapse
Affiliation(s)
- P R Kowey
- Cardiac Arrhythmia Service, Lankenau Hospital and Medical Research Center, Wynnewood, PA
| | | | | | | | | |
Collapse
|
13
|
Olson PJ, Woelfel A, Simpson RJ, Foster JR. Stratification of sudden death risk in patients receiving long-term amiodarone treatment for sustained ventricular tachycardia or ventricular fibrillation. Am J Cardiol 1993; 71:823-6. [PMID: 8456761 DOI: 10.1016/0002-9149(93)90831-v] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
One hundred twenty-two patients treated chronically with amiodarone for sustained ventricular tachycardia or ventricular fibrillation after failing conventional antiarrhythmic therapy were analyzed to determine which factors were predictive of sudden cardiac death during follow-up. The mean left ventricular ejection fraction in the study group was 0.32, and 87% of the patients had coronary artery disease with a prior myocardial infarction. During a median follow-up of 19.5 months, 30 patients died suddenly. The only variable that was predictive of sudden death was left ventricular ejection fraction. Twenty-nine of the 84 patients with ejection fractions < 0.40 died suddenly, compared with 1 of 35 patients with ejection fractions > or = 0.40. The actuarial probability of sudden death at 5 years was 49% when the ejection fraction was < 0.40, and 5% when the ejection fraction was > or = 0.40 (p = 0.0004). These results indicate that patients treated with amiodarone for sustained ventricular tachycardia or ventricular fibrillation whose ejection fractions are > or = 0.40 are at low risk for sudden death. Patients with ejection fractions < 0.40 remain at high risk for sudden death, and should be considered for additional or alternative therapy.
Collapse
Affiliation(s)
- P J Olson
- Division of Cardiology, University of North Carolina School of Medicine, Chapel Hill
| | | | | | | |
Collapse
|
14
|
|
15
|
NATTEL STANLEY, TALAJIC MARIO, FERMINI BERNARD, ROY DENIS. Amiodarone: Pharmacology, Clinical Actions, and Relationships Between Them. J Cardiovasc Electrophysiol 1992. [DOI: 10.1111/j.1540-8167.1992.tb00972.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
Gill J, Heel RC, Fitton A. Amiodarone. An overview of its pharmacological properties, and review of its therapeutic use in cardiac arrhythmias. Drugs 1992; 43:69-110. [PMID: 1372862 DOI: 10.2165/00003495-199243010-00007] [Citation(s) in RCA: 114] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Amiodarone, originally developed over 20 years ago, is a potent antiarrhythmic drug with the actions of all antiarrhythmic drug classes. It has been successfully used in the treatment of symptomatic and life-threatening ventricular arrhythmias and symptomatic supraventricular arrhythmias. In patients with left ventricular dysfunction amiodarone does not usually produce any clinically significant cardiodepression and the drug has relatively high antiarrhythmic efficacy. Preliminary studies indicate that amiodarone may have a beneficial effect on mortality and survival in certain groups of patients with ventricular arrhythmias, an action probably related to both its antiarrhythmic and antifibrillatory effects. The adverse effect profile of amiodarone is diverse, involving the cardiac, thyroid, pulmonary, hepatic, gastrointestinal, ocular, neurological and dermatological systems. Interstitial pneumonitis and hepatitis are potentially fatal, but the vast majority of adverse events are less serious, and some may be dose dependent. Pretreatment monitoring, regular assessments and the use of minimum effective doses are, therefore, necessary. Thus, with appropriate monitoring to control its well recognised adverse effects amiodarone has an important place as an effective 'broad spectrum' antiarrhythmic drug which has, so far, been used when other treatments have proved ineffective. More recent preliminary data also suggest that it may also have a beneficial effect in the prevention of sudden death in some patients.
Collapse
Affiliation(s)
- J Gill
- Adis International Limited, Chester, UK
| | | | | |
Collapse
|
17
|
Larsen GC, Manolis AS, Sonnenberg FA, Beshansky JR, Estes NA, Pauker SG. Cost-effectiveness of the implantable cardioverter-defibrillator: effect of improved battery life and comparison with amiodarone therapy. J Am Coll Cardiol 1992; 19:1323-34. [PMID: 1564234 DOI: 10.1016/0735-1097(92)90341-j] [Citation(s) in RCA: 78] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The implantable cardioverter-defibrillator (ICD) greatly reduces the incidence of sudden cardiac death among patients with recurrent sustained ventricular tachycardia and fibrillation who do not respond to conventional antiarrhythmic therapy. A cost-effectiveness analysis was performed, comparing the ICD, amiodarone and conventional agents. Actual variable costs of hospitalization and follow-up care were used for 21 ICD- and 43 amiodarone-treated patients. Life expectancy and total variable costs were predicted with use of a Markov decision analytic model. Clinical event rates and probabilities were based on published reports or expert opinion. Life expectancy with an ICD (6.1 years) was 50% greater than that associated with treatment with amiodarone (3.9 years) and 2.5 times that associated with conventional treatment (2.5 years). Assuming replacement every 24 months, ICD lifetime treatment costs (in 1989 dollars) for a 55-year old patient are expected to be $89,600 compared with $24,800 for amiodarone and $16,100 for conventional therapy, yielding a marginal cost/effectiveness ratio for ICD versus amiodarone therapy of 1f429,200/year of life saved, which is comparable to that of other accepted medical treatments. If technologic improvements extend average battery life to 36 months, the marginal cost/effectiveness ratio would be $21,800/year of life saved, and at 96 months it would be $13,800/year of life saved. Patient age at implantation did not significantly affect these results. If quality of life on amiodarone therapy is 30% lower than that with the ICD, the marginal cost/effectiveness ratio decreases by 35%. If the quality of life for patients receiving drugs is 40% lower than that of patients treated with an ICD, use of the defibrillator becomes the dominant strategy.
Collapse
Affiliation(s)
- G C Larsen
- Department of Medicine, New England Medical Center, Boston, Massachusetts
| | | | | | | | | | | |
Collapse
|
18
|
Evans SJ, Myers M, Zaher C, Simonson J, Nalos P, Vaughn C, Oseran D, Gang E, Peter T, Mandel W. High dose oral amiodarone loading: electrophysiologic effects and clinical tolerance. J Am Coll Cardiol 1992; 19:169-73. [PMID: 1729329 DOI: 10.1016/0735-1097(92)90069-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Although amiodarone is an effective drug for the treatment of life-threatening ventricular arrhythmias, no standard oral loading dose protocol has been defined, and patients often undergo prolonged hospitalization for amiodarone loading. High dose (greater than 1,800 mg/day) oral loading has usually been reserved for unstable patients with incessant ventricular tachyarrhythmias. The current study was designed to 1) examine the clinical and electrophysiologic effects of a high dose oral amiodarone loading regimen in more stable patients; and 2) ascertain its safety and tolerance, possibly allowing shortened amiodarone loading periods and potentially decreased length of hospital stay. The study group included 16 patients with a history of recurrent ventricular arrhythmias and decreased left ventricular function, who were refractory to prior antiarrhythmic drug therapy. The oral loading protocol was 50 mg/kg per day of amiodarone for 3 days, then 30 mg/kg per day for 2 days, followed by maintenance therapy of 300 to 400 mg twice daily. Electrophysiologic testing was performed at baseline, on days 1 and 5 and during week 6. Amiodarone and desethylamiodarone levels were measured and symptoms monitored. Clinically, the high dose loading protocol was well tolerated in 15 of the 16 patients. Arrhythmias were rendered noninducible by day 1 in three patients and remained noninducible throughout the study period in two of the three. The remaining patients continued to have inducible ventricular tachycardia. Ventricular tachycardia cycle length and right ventricular effective refractory period both progressively increased significantly over baseline, starting on day 1. The 15 patients who remained in the study had no significant side effects during the loading period.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- S J Evans
- Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles 90048
| | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Abstract
Nonpharmacologic therapy for ventricular arrhythmias has gained growing attention with the development of the implantable cardioverter-defibrillator. In addition, the reports of adverse effects of drug therapy from several studies, including the Cardiac Arrhythmia Suppression Trial (CAST), have supported the need for these devices. The development of new implantable cardioverter-defibrillators that have the capability of antitachycardia pacing, bradycardia pacing, cardioversion and defibrillation has enhanced their clinical utility. The currently available implantable cardioverter-defibrillators have been shown to significantly improve survival after sudden cardiac arrest in patients with life-threatening ventricular arrhythmias. Newer devices with expanded capabilities may reduce mortality even further. In this report the features of currently available antitachycardia devices and implantable cardioverter-defibrillators are reviewed and the features and current implant data on newer antitachycardia devices are discussed.
Collapse
Affiliation(s)
- L S Klein
- Krannert Institute of Cardiology, Indianapolis, Indiana 46202-4800
| | | | | |
Collapse
|
20
|
Morady F, Kadish A, de Buitleir M, Kou WH, Calkins H, Schmaltz S, Rosenheck S, Sousa J. Prospective comparison of a conventional and an accelerated protocol for programmed ventricular stimulation in patients with coronary artery disease. Circulation 1991; 83:764-73. [PMID: 1999027 DOI: 10.1161/01.cir.83.3.764] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND This study compared the sensitivity, specificity, and efficiency of a "conventional" and "accelerated" programmed stimulation protocol in 293 patients with coronary artery disease who had a history of sustained or nonsustained monomorphic ventricular tachycardia (VT). METHODS AND RESULTS In the conventional protocol, one and two extrastimuli were introduced during sinus rhythm and during basic drive trains at cycle lengths of 600 and 400 msec at the right ventricular apex and then at the outflow tract or septum. In the accelerated protocol, one, two, and then three extrastimuli were introduced at each of three basic drive train cycle lengths (350, 400, and 600 msec) at the right ventricular apex; the procedure was repeated at a second right ventricular site. Six hundred thirty-four electrophysiological tests were performed using one of these two protocols either in the baseline state (293 tests) or during drug testing (341 tests). The yield of sustained, monomorphic VT was 89% with the conventional protocol and 92% with the accelerated protocol during baseline tests in patients who had a history of sustained VT (p = 0.05); 20% and 34%, respectively, during baseline tests in patients with a history of nonsustained VT (p = 0.06); and 70% and 77%, respectively, during drug testing (p = 0.2). To induce sustained, monomorphic VT, 10.1 +/- 5.0 (mean +/- SD) protocol steps and 14.4 +/- 8.7 minutes were required with the conventional protocol, compared with 4.0 +/- 3.7 steps and 5.6 +/- 6.1 minutes with the accelerated protocol (p less than 0.001 for each comparison). Among the tests in which sustained, monomorphic VT was induced, sustained polymorphic VT or ventricular fibrillation was induced more often with the conventional protocol (3.6%) than with the accelerated protocol (0.9%, p = 0.05). CONCLUSIONS The efficiency of programmed stimulation can be improved by the early use of a basic drive train cycle length of 350 msec and three extrastimuli. Compared with a conventional stimulation protocol, the accelerated protocol used in this study reduces the number of protocol steps and duration of time required to induce monomorphic VT by an average of more than 50% and improves the specificity of programmed stimulation without impairing the yield of monomorphic VT.
Collapse
Affiliation(s)
- F Morady
- Division of Cardiology, University of Michigan Medical Center, Ann Arbor 48109-0022
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Abstract
With the limitations of currently available modalities for treating clinically important tachycardias, the role of implanted antitachycardia devices will continue to expand. The challenge of the future will not only involve continued technological advances but the socioeconomic impact of this efficacious but expensive mode of therapy in an era of increasing financial restraints. Further studies to definitively prove the efficacy of more widespread use of antitachycardia device therapy will be needed.
Collapse
Affiliation(s)
- M E Rosenthal
- Clinical Electrophysiology Laboratory, Hospital of the University of Pennsylvania, Philadelphia 19104
| | | |
Collapse
|
22
|
Leclercq JF, Leenhardt A, Lemarec H, Clémenty J, Hermida JS, Sebag C, Aliot E. Predictive value of electrophysiologic studies during treatment of ventricular tachycardia with the beta-blocking agent nadolol. The Working Group on Arrhythmias of the French Society of Cardiology. J Am Coll Cardiol 1990; 16:413-7. [PMID: 2373820 DOI: 10.1016/0735-1097(90)90594-f] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Sixty patients with recurrent inducible sustained ventricular tachycardia were prospectively treated with nadolol (40 or 80 mg/day). Old myocardial infarction was present in 43 patients and dilated cardiomyopathy in 12. In group I (n = 36), nadolol was given alone, whereas in group II (n = 24), previously ineffective treatment with amiodarone was continued in combination with nadolol. Left ventricular ejection fraction was higher in patients in group I (0.40 +/- 0.12) than in group II (0.30 +/- 0.10, p less than 0.01) patients. Electrophysiologic study was repeated after short-term treatment with nadolol, which was continued regardless of the results of this test, according to the scheme of the parallel approach. Recurrence of spontaneous tachycardia or sudden death occurred in 21 patients after 10 +/- 9.2 months; sustained tachycardia was inducible in 19 on nadolol therapy. The remaining 39 patients (of whom 21 had inducible tachycardia while taking the drug) have had no recurrence of tachycardia after 27.8 +/- 9.3 months of follow-up study. Sensitivity, specificity and predictive value of a positive and negative test were 90.5%, 46%, 47.5% and 90%, respectively. The results differ between group I and group II patients, the latter having a high percent of false positive responses. This difference is even more obvious with respect to left ventricular ejection fraction: the predictive value of a positive test was 86% when ejection fraction was greater than 0.40 and 39% when it was less than 0.40.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
23
|
Manolis AS, Uricchio F, Estes NA. Prognostic value of early electrophysiologic studies for ventricular tachycardia recurrence in patients with coronary artery disease treated with amiodarone. Am J Cardiol 1989; 63:1052-7. [PMID: 2705375 DOI: 10.1016/0002-9149(89)90077-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Amiodarone was used in 86 patients with ventricular tachycardia (VT) (67 patients) or ventricular fibrillation (19 patients) secondary to coronary artery disease. The mean +/- standard deviation left ventricular ejection fraction was 30 +/- 12% (range 8 to 65%). Prior trials with 4 +/- 1.2 alternate antiarrhythmic agents had been unsuccessful. Amiodarone was loaded at dosages of 1,200 to 1,800 mg/day, with maintenance dosages of 400 to 600 mg/day. Drug efficacy was evaluated by programmed stimulation at 10 to 14 days in 68 patients. In 38 patients sustained VT or ventricular fibrillation was inducible (group I), whereas 30 patients (group II) had either no inducible VT (8) or had nonsustained VT induced (22). Holter monitoring was used to assess drug efficacy in 18 patients (group III). All patients were evaluated at 3- to 6-month intervals with Holter monitors for efficacy and a standard protocol for toxicity. During a long-term follow-up of 18 +/- 16 months, sudden death occurred in 5 patients and nonfatal arrhythmia recurrences were detected in 16. The actuarial probability of freedom from fatal and nonfatal arrhythmia recurrences at 24 months was 0.52 for group I, 0.97 for group II and 0.68 for group III. The mode of induction, rate change or hemodynamic tolerance of the induced ventricular tachycardia did not predict arrhythmia recurrence. Among the clinical variables analyzed, only an ejection fraction of less than or equal to 30% was identified as a significant predictor of arrhythmia recurrence. Nonsudden cardiac death occurred in 21 patients, including 19 from heart failure and 2 from myocardial infarction. Noncardiac death occurred in 7 patients.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- A S Manolis
- Department of Medicine, Tufts University School of Medicine, Boston, Massachusetts
| | | | | |
Collapse
|
24
|
Affiliation(s)
- T A Mattioni
- Department of Medicine, Northwestern University School of Medicine, Chicago, IL 60611
| | | | | | | |
Collapse
|
25
|
Greene HL. The efficacy of amiodarone in the treatment of ventricular tachycardia or ventricular fibrillation. Prog Cardiovasc Dis 1989; 31:319-54. [PMID: 2646655 DOI: 10.1016/0033-0620(89)90029-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- H L Greene
- Electrophysiology Laboratory, Harborview Medical Center, University of Washington, Seattle 98104
| |
Collapse
|