1
|
Urbanowicz M, Sadowska K, Pijanowska DG, Pomećko R, Bocheńska M. Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva. SENSORS (BASEL, SWITZERLAND) 2020; 20:E2817. [PMID: 32429165 PMCID: PMC7288078 DOI: 10.3390/s20102817] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/06/2020] [Accepted: 05/12/2020] [Indexed: 12/13/2022]
Abstract
A new solid-contact potentiometric ion-selective electrode for the determination of SCN- (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included selection of a plasticizer for the ion-selective membrane composition and type of the electrode material. The study was carried out using ISE with liquid internal electrolyte (LE-ISE) and solid-contact electrodes made of glassy carbon (GC-ISE) and gold rods (Au-ISE). The best parameters were found for GC sensors for which the ion-selective membrane contained chloroparaffin as a plasticizer (S = 59.9 mV/dec, LOD = 1.6 ´ 10-6 M). The study of potentiometric selectivity coefficients has shown that the thiocyanate-selective sensor could be applied in biomedical research for determination of SCN- concentration in human saliva. The accuracy of the SCN- determination was verified by testing 59 samples of volunteers' saliva by potentiometric sensors and UV-Vis spectrophotometry as a reference technique. Moreover, SCN- concentrations in the smokers' and non-smokers' saliva were compared. In order to investigate the influence of various factors (sex, health status, taken medications) on the thiocyanate level in the saliva, more extensive studies on a group of 100 volunteers were carried out. Additionally, for a group of 18 volunteers, individual profiles of SCN- concentration in saliva measured on a daily basis for over a month were collected.
Collapse
Affiliation(s)
- Marcin Urbanowicz
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Ks. Trojdena 4, 02-109 Warsaw, Poland; (K.S.); (D.G.P.)
| | - Kamila Sadowska
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Ks. Trojdena 4, 02-109 Warsaw, Poland; (K.S.); (D.G.P.)
| | - Dorota G. Pijanowska
- Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Ks. Trojdena 4, 02-109 Warsaw, Poland; (K.S.); (D.G.P.)
| | - Radosław Pomećko
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland; (R.P.); (M.B.)
| | - Maria Bocheńska
- Department of Chemistry and Technology of Functional Materials, Chemical Faculty, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland; (R.P.); (M.B.)
| |
Collapse
|
2
|
|
3
|
Shamsipur M, Tashkhourian J, Hasaninejad A, Sharghi H. Potentiometric Behavior of Co(II)-Meso-tetraarylporphyrin Derivatives as Ionophores in Anion-Selective Electrodes. Cross Sensitivity Studies. ANAL LETT 2010. [DOI: 10.1080/00032710903276588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
4
|
|
5
|
Dong YY, Li CY, Zhang XB, Yu RQ, Shen GL. A Novel Potentiometric Sensor for Thiocyanate Based on an Amide-Linked Manganese Diporphyrin Xanthene. ELECTROANAL 2008. [DOI: 10.1002/elan.200804239] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
6
|
Yang P, Wei W, Tao C. Determination of trace thiocyanate with nano-silver coated multi-walled carbon nanotubes modified glassy carbon electrode. Anal Chim Acta 2007; 585:331-6. [PMID: 17386682 DOI: 10.1016/j.aca.2007.01.011] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2006] [Revised: 01/02/2007] [Accepted: 01/11/2007] [Indexed: 10/23/2022]
Abstract
Novel nano-silver coated multi-walled carbon nanotube composites were prepared and used to fabricate a modified electrode. The application of the nano-silver coated multi-walled carbon nanotube composites modified electrode for determination of trace thiocyanate is demonstrated for the first time. The influence of substrate, pH and interference of coexisting substances was investigated for response properties of the electrode. There was a linear relationship at the range 2.5 x 10(-9) to 5 x 10(-8) mol L(-1) and 5 x 10(-8) to 1 x 10(-6) mol L(-1) of thiocyanate with the decrement of anodic DPV peak currents. The limit of detection was 1 x 10(-9) mol L(-1)(S/N=3). The constructed electrode showed excellent reproducibility and stability. Actual urine and saliva samples of smoker and non-smoker were analyzed and satisfactory results were obtained. This method provides a new way to construct any electrode for biological and environmental analysis.
Collapse
Affiliation(s)
- Pinghua Yang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, PR China
| | | | | |
Collapse
|
7
|
Hassan S, Mohmoud W, Elgazwy AS, Badawy N. A Novel Potentiometric Membrane Sensor Based on Aryl Palladium Complex for Selective Determination of Thiocyanate in the Saliva and Urine of Cigarette Smokers. ELECTROANAL 2006. [DOI: 10.1002/elan.200603640] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
8
|
Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects. B KOREAN CHEM SOC 2004. [DOI: 10.5012/bkcs.2004.25.10.1484] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
9
|
Armijo F, Isaacs M, Ramı́rez G, Trollund E, Canales J, Aguirre MJ. Electrocatalytic reduction of nitrate ion on Cu and Ni poly-tetraaminophenylporphyrin-modified electrodes. J Electroanal Chem (Lausanne) 2004. [DOI: 10.1016/j.jelechem.2003.11.043] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Valdés M, Díaz-García M. Determination of Thiocyanate within Physiological Fluids and Environmental Samples: Current Practice and Future Trends. Crit Rev Anal Chem 2004. [DOI: 10.1080/10408340490273726] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
11
|
Hassan SS, Abou Ghalia M, Amr AGE, Mohamed AH. Novel thiocyanate-selective membrane sensors based on di-, tetra-, and hexa-imidepyridine ionophores. Anal Chim Acta 2003. [DOI: 10.1016/s0003-2670(03)00172-7] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
Abstract
Poly(vinyl chloride) membrane sensors for Ca(II) ions were constructed based on bilirubin (1,3,6,7-tetramethyl-4,5-dicarboxyethy-2,8-divinyl-[b-13]-dihydrobilenone) as a neutral carrier in the presence of various plasticizers (o-nitrophenyloctyl ether, dioctyl phethalate and dibutyl sebacate), which were used as solvent mediators to incorporate the carrier into the membranes. The role of plasticizers as a medium of complexation was demonstrated. The influences of an anionic excluder, the pH and foreign ions were investigated. The selectivity coefficients were measured by a separate solution method. Among the plasticizers used, o-nitrophenyloctyl ether gave the best selectivity in the presence of large concentrations of alkali and alkaline earth's metal ions. Using sensor number I, a linear calibration graph with a good Nernstian slope of 29.5 +/- 0.8 mV was obtained for Ca(II) concentrations of 5 x 10(-7)-10(-2) mol l(-1) with a detection limit of 3 x 10(-7) mol l(-1) (12 ppb). The sensor can be used for more than 3 months with good reproducibility and a fast response time of 10 s. The developed sensor has been successfully applied to the analysis of some pharmaceutical formulations, baby-food products and human plasma. Moreover, it can be used as an indicator sensor in the potentiometric titration of Ca(II) with EDTA.
Collapse
Affiliation(s)
- Wagiha H Mahmoud
- Department of Chemistry, Faculty of Science, Ain Shams University, Abassia, Cairo, 11566, Egypt
| |
Collapse
|
13
|
Malinowska E, Niedziółka J, Roźniecka E, Meyerhoff ME. Salicylate-selective membrane electrodes based on Sn(IV)- and OMo(V)-porphyrins: differences in response mechanism and analytical performance. J Electroanal Chem (Lausanne) 2001. [DOI: 10.1016/s0022-0728(01)00615-5] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
14
|
Potentiometric and spectroscopic characterization of anion selective electrodes based on metal(III) porphyrin ionophores in polyurethane membranes. Anal Chim Acta 2001. [DOI: 10.1016/s0003-2670(00)01348-9] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Leyzerovich NN, Shvedene NV, Blikova YN, Tomilova LG, Pletnev IV. Comparative Study of the Metal Phthalocyanates as Active Components in Salicylate-Selective Electrodes. ELECTROANAL 2001. [DOI: 10.1002/1521-4109(200103)13:3<246::aid-elan246>3.0.co;2-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
16
|
|
17
|
Bühlmann P, Pretsch E, Bakker E. Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. Chem Rev 1998; 98:1593-1688. [PMID: 11848943 DOI: 10.1021/cr970113+] [Citation(s) in RCA: 1275] [Impact Index Per Article: 49.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Philippe Bühlmann
- Department of Chemistry, School of Science, The University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-0033, Japan, Department of Organic Chemistry, Swiss Federal Institute of Technology (ETH), Universitätstrasse 16, CH-8092 Zürich, Switzerland, and Department of Chemistry, Auburn University, Auburn, Alabama 36849
| | | | | |
Collapse
|
18
|
STEINLE ED, SCHALLER U, MEYERHOFF ME. Response Characteristics of Anion-Selective Polymer Membrane Electrodes Based on Gallium(III), Indium(III) and Thallium(III) Porphyrins. ANAL SCI 1998. [DOI: 10.2116/analsci.14.79] [Citation(s) in RCA: 98] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
19
|
|