1
|
Kalendra V, Turčak J, Usevičius G, Karas H, Hülsmann M, Godt A, Jeschke G, Banys J, Morton JJL, Šimėnas M. Q-band EPR cryoprobe. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 356:107573. [PMID: 37856964 DOI: 10.1016/j.jmr.2023.107573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 10/09/2023] [Accepted: 10/11/2023] [Indexed: 10/21/2023]
Abstract
Following the success of cryogenic EPR signal preamplification at X-band, we present a Q-band EPR cryoprobe compatible with a standard EPR resonator. The probehead is equipped with a cryogenic ultra low-noise microwave amplifier and its protection circuit that are placed close to the sample in the same cryostat. Our cryoprobe maintains the same sample access and tuning which is typical in Q-band EPR, as well as supports high-power pulsed experiments on typical samples. The performance of our setup is benchmarked against that of existing commercial and home-built Q-band spectrometers, using CW EPR and pulsed EPR/ENDOR experiments to reveal a significant sensitivity improvement which reduces the measurement time by a factor of about 40× at 6 K temperature at reduced power levels.
Collapse
Affiliation(s)
- Vidmantas Kalendra
- Faculty of Physics, Vilnius University, Sauletekio 3, LT-10257 Vilnius, Lithuania; Amplify My Probe Ltd., London NW1 1NJ, UK
| | - Justinas Turčak
- Faculty of Physics, Vilnius University, Sauletekio 3, LT-10257 Vilnius, Lithuania
| | - Gediminas Usevičius
- Faculty of Physics, Vilnius University, Sauletekio 3, LT-10257 Vilnius, Lithuania
| | - Hugo Karas
- Department of Chemistry and Applied Biosciences, ETH Zurich, Vladimir-Prelog-Weg 1-5/10, 8093 Zurich, Switzerland
| | - Miriam Hülsmann
- Faculty of Chemistry and Center for Molecular Materials (CM(2)), Bielefeld University, Universitätsstraße 25, 33615 Bielefeld, Germany
| | - Adelheid Godt
- Faculty of Chemistry and Center for Molecular Materials (CM(2)), Bielefeld University, Universitätsstraße 25, 33615 Bielefeld, Germany
| | - Gunnar Jeschke
- Department of Chemistry and Applied Biosciences, ETH Zurich, Vladimir-Prelog-Weg 1-5/10, 8093 Zurich, Switzerland
| | - Jūras Banys
- Faculty of Physics, Vilnius University, Sauletekio 3, LT-10257 Vilnius, Lithuania
| | - John J L Morton
- London Centre for Nanotechnology, University College London, London WC1H 0AH, UK; Department of Electronic & Electrical Engineering, University College London, London WC1E 7JE, UK
| | - Mantas Šimėnas
- Faculty of Physics, Vilnius University, Sauletekio 3, LT-10257 Vilnius, Lithuania.
| |
Collapse
|
2
|
Vasquez JK, Zhou Z, Clark B, Kimenai AJ, Reiner BR, Rau NJ, Baugh D, Eldred DV, Paradkar M, Zheng C, DeFelippis J, Potter JM, Qiu XH, Zong X, Young WO, Fitzgibbons T, Moreno A, Freudenberger C, Mayzel M. Removing acoustic ringing baseline curvature in 13 C NMR spectra for quantitative analyses. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2023; 61:544-553. [PMID: 37551084 DOI: 10.1002/mrc.5384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 07/11/2023] [Accepted: 07/14/2023] [Indexed: 08/09/2023]
Abstract
13 C nuclear magnetic resonance (NMR) is traditionally considered an insensitive technique, requiring long acquisition times to measure dilute functionalities on large polymers. With the introduction of cryoprobes and better electronics, sensitivity has improved in a way that allows measurements to take less than 1/20th the time that they previously did. Unfortunately, a high Q-factor with cryoprobes creates baseline curvature related to acoustic ringing that affects quantitative NMR analyses. Manual baseline correction is commonly used to compensate for the baseline roll, but it is a time-intensive process. The outcome of manual baseline correction can vary depending on processing parameters, especially for complicated spectra. Additionally, it can be challenging to distinguish between broad peaks and baseline rolls. A new anti-ring pulse sequence (zgig_pisp) was previously reported to improve on the incumbent single pulse experiment (zgig). The original report presented limited comparison data with 13 C NMR, but a thorough validation is needed before broader implementation can be considered. In this work, we report the round-robin testing and comparison of zgig_pisp and zgig pulse sequences. During the testing phase, we found that zgig_pisp is practically equivalent to zgig to ±2% for the majority of integrals examined. Additionally, a short broadband inversion pulse (BIP) was demonstrated as an alternative to the originally reported adiabatic CHIRP shaped pulse. The zgig_pisp pulse sequence code for Bruker spectrometers is also simplified.
Collapse
|
3
|
Wang W, Sánchez-Heredia JD, Olin RB, Hansen ESS, Laustsen C, Zhurbenko V, Ardenkjaer-Larsen JH. A cryogenic 14-channel 13 C receiver array for 3T human head imaging. Magn Reson Med 2023; 89:1265-1277. [PMID: 36321576 PMCID: PMC10092528 DOI: 10.1002/mrm.29508] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 09/09/2022] [Accepted: 10/11/2022] [Indexed: 12/27/2022]
Abstract
PURPOSE This article presents a novel 14-channel receive-only array for 13 C human head imaging at 3 T that explores the SNR gain by operating at cryogenic temperature cooled by liquid nitrogen. METHODS Cryostats are developed to evaluate single-coil bench SNR performance and cool the 14-channel array with liquid nitrogen while having enough thermal insulation between the coils and the sample. The temperature distribution for the coil array is measured. Circuits are adapted to the -189°C environment and implemented in the 14-channel array. 13 C images are acquired with the array at cryogenic and room temperature in a 3T scanner. RESULTS Compared with room temperature, the array at cryogenic temperature provides 27%-168% SNR improvement over all voxels and 47% SNR improvement near the image center. The measurements show a decrease of the element noise correlation at cryogenic temperature. CONCLUSION It is demonstrated that higher SNR can be achieved by cryogenically cooling the 14-channel array. A cryogenic array suitable for clinical imaging can be further developed on the array proposed. The cryogenic coil array is most likely suited for scenarios in which high SNR deep in a head and decent SNR on the periphery are required.
Collapse
Affiliation(s)
- Wenjun Wang
- National Space Institute, Technical University of Denmark, Kongens Lyngby, Denmark
| | | | - Rie Beck Olin
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
| | | | - Christoffer Laustsen
- MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Vitaliy Zhurbenko
- National Space Institute, Technical University of Denmark, Kongens Lyngby, Denmark
| | | |
Collapse
|
4
|
Eichhorn TR, Parker AJ, Josten F, Müller C, Scheuer J, Steiner JM, Gierse M, Handwerker J, Keim M, Lucas S, Qureshi MU, Marshall A, Salhov A, Quan Y, Binder J, Jahnke KD, Neumann P, Knecht S, Blanchard JW, Plenio MB, Jelezko F, Emsley L, Vassiliou CC, Hautle P, Schwartz I. Hyperpolarized Solution-State NMR Spectroscopy with Optically Polarized Crystals. J Am Chem Soc 2022; 144:2511-2519. [PMID: 35113568 DOI: 10.1021/jacs.1c09119] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Nuclear spin hyperpolarization provides a promising route to overcome the challenges imposed by the limited sensitivity of nuclear magnetic resonance. Here we demonstrate that dissolution of spin-polarized pentacene-doped naphthalene crystals enables transfer of polarization to target molecules via intermolecular cross-relaxation at room temperature and moderate magnetic fields (1.45 T). This makes it possible to exploit the high spin polarization of optically polarized crystals, while mitigating the challenges of its transfer to external nuclei. With this method, we inject the highly polarized mixture into a benchtop NMR spectrometer and observe the polarization dynamics for target 1H nuclei. Although the spectra are radiation damped due to the high naphthalene magnetization, we describe a procedure to process the data to obtain more conventional NMR spectra and extract the target nuclei polarization. With the entire process occurring on a time scale of 1 min, we observe NMR signals enhanced by factors between -200 and -1730 at 1.45 T for a range of small molecules.
Collapse
Affiliation(s)
| | - Anna J Parker
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany
| | - Felix Josten
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany
| | | | | | - Jakob M Steiner
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany.,Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Martin Gierse
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany.,Institute for Quantum Optics, Ulm University, 89081 Ulm, Germany
| | | | - Michael Keim
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany
| | | | | | - Alastair Marshall
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany.,Institute for Quantum Optics, Ulm University, 89081 Ulm, Germany
| | - Alon Salhov
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany.,Racah Institute of Physics, The Hebrew University of Jerusalem, Jerusalem 91904, Givat Ram, Israel
| | - Yifan Quan
- Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Jan Binder
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany
| | - Kay D Jahnke
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany
| | | | | | | | - Martin B Plenio
- Institute for Theoretical Physics, Ulm University, 89081 Ulm, Germany.,Center for Integrated Quantum Science and Technology, Ulm University, 89081 Ulm, Germany
| | - Fedor Jelezko
- Institute for Quantum Optics, Ulm University, 89081 Ulm, Germany.,Center for Integrated Quantum Science and Technology, Ulm University, 89081 Ulm, Germany
| | - Lyndon Emsley
- Institut des Sciences et Ingénierie Chimiques, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
| | | | | | - Ilai Schwartz
- NVision Imaging Technologies GmbH, 89081 Ulm, Germany
| |
Collapse
|
5
|
Sestile S, Richardson D, Toomey R, Cool LG, Harper JK. NMR structural characterization from one-bond 13 C 13 C couplings: Complete assignment of a hydrogen-poor depsidone. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2021; 59:23-33. [PMID: 32687644 DOI: 10.1002/mrc.5077] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 06/20/2020] [Accepted: 07/16/2020] [Indexed: 06/11/2023]
Abstract
The connectivity, conformation, tautomeric form, and dynamics of a new depsidone (perisalazinic acid) were characterized using one-bond 13 C13 C NMR scalar couplings (1 JCC ) obtained from the INADEQUATE experiment. Characterization of perisalazinic acid using more conventional NMR techniques is problematic due to the extremely limited number of CH protons present. In the present study, 81 candidate structures were considered and a best fit structure was selected by comparing computed 1 JCC values for each candidate to 15 experimental values. Of the six flexible moieties in perisalazinic acid, three are adequately represented by a single orientation stabilized by intramolecular hydrogen bonding. The three remaining groups are present as mixtures of conformers with two sites consisting of a pair of conformations and another disordered over six orientations. This study demonstrates the feasibility of complete three-dimensional structural characterization of an unknown using only theoretical and experimental 1 JCC values.
Collapse
Affiliation(s)
- Shannon Sestile
- Department of Chemistry, University of Central Florida, Orlando, FL, USA
| | - David Richardson
- Department of Chemistry, University of Central Florida, Orlando, FL, USA
| | - Ryan Toomey
- Department of Chemistry, Utah Valley University, Orem, UT, USA
| | - Laurence G Cool
- Agricultural Research Service, United States Department of Agriculture, Albany, CA, USA
| | - James K Harper
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA
| |
Collapse
|
6
|
Saniour I, Authelet G, Baudouy B, Dubuisson RM, Jourdain L, Willoquet G, Darrasse L, Ginefri JC, Poirier-Quinot M. A temperature-controlled cryogen free cryostat integrated with transceiver-mode superconducting coil for high-resolution magnetic resonance imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:055106. [PMID: 32486746 DOI: 10.1063/1.5143107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Accepted: 05/01/2020] [Indexed: 06/11/2023]
Abstract
Small-sized High Temperature Superconducting (HTS) radiofrequency coils are used in a number of micro-magnetic resonance imaging applications and demonstrate a high detection sensitivity that improves the signal-to-noise ratio. However, the use of HTS coils could be limited by the rarity of cryostats that are suitable for the MR environment. This study presents a magnetic resonance (MR)-compatible and easily operated cryogen-free cryostat based on the pulse tube cryocooler technology for the cooling and monitoring of HTS coils below the temperature of liquid nitrogen. This cryostat features a real-time temperature control function that allows the precise frequency adjustment of the HTS coil. The influence of the temperature on the electrical properties, resonance frequency (f0), and quality factor (Q) of the HTS coil was investigated. Temperature control is obtained with an accuracy of over 0.55 K from 60 K to 86 K, and the sensitivity of the system, extracted from the frequency measurement from 60 K to 75 K, is of about 2 kHz/K, allowing a fine retuning (within few Hz, compared to 10 kHz bandwidth) in good agreement with experimental requirements. We demonstrated that the cryostat, which is mainly composed of non-magnetic materials, does not perturb the electromagnetic field in any way. MR images of a 10 × 10 × 15 mm3 liquid phantom were acquired using the HTS coil as a transceiver with a spatial resolution of 100 × 100 × 300 µm3 in less than 20 min under experimental conditions at 1.5 T.
Collapse
Affiliation(s)
- Isabelle Saniour
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Orsay, France
| | - Gilles Authelet
- Irfu, CEA, Université Paris-Saclay, F-91191 Gif-sur-Yvette, France
| | - Bertrand Baudouy
- Irfu, CEA, Université Paris-Saclay, F-91191 Gif-sur-Yvette, France
| | | | - Laurène Jourdain
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Orsay, France
| | | | - Luc Darrasse
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Orsay, France
| | | | | |
Collapse
|
7
|
de Graaf RA, Hendriks AD, Klomp DWJ, Kumaragamage C, Welting D, de Castro CSA, Brown PB, McIntyre S, Nixon TW, Prompers JJ, De Feyter HM. On the magnetic field dependence of deuterium metabolic imaging. NMR IN BIOMEDICINE 2020; 33:e4235. [PMID: 31879985 PMCID: PMC7141779 DOI: 10.1002/nbm.4235] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 10/15/2019] [Accepted: 11/10/2019] [Indexed: 05/23/2023]
Abstract
Deuterium metabolic imaging (DMI) is a novel MR-based method to spatially map metabolism of deuterated substrates such as [6,6'-2 H2 ]-glucose in vivo. Compared with traditional 13 C-MR-based metabolic studies, the MR sensitivity of DMI is high due to the larger 2 H magnetic moment and favorable T1 and T2 relaxation times. Here, the magnetic field dependence of DMI sensitivity and transmit efficiency is studied on phantoms and rat brain postmortem at 4, 9.4 and 11.7 T. The sensitivity and spectral resolution on human brain in vivo are investigated at 4 and 7 T before and after an oral dose of [6,6'-2 H2 ]-glucose. For small animal surface coils (Ø 30 mm), the experimentally measured sensitivity and transmit efficiency scale with the magnetic field to a power of +1.75 and -0.30, respectively. These are in excellent agreement with theoretical predictions made from the principle of reciprocity for a coil noise-dominant regime. For larger human surface coils (Ø 80 mm), the sensitivity scales as a +1.65 power. The spectral resolution increases linearly due to near-constant linewidths. With optimal multireceiver arrays the acquisition of DMI at a nominal 1 mL spatial resolution is feasible at 7 T.
Collapse
Affiliation(s)
- Robin A. de Graaf
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Arjan D. Hendriks
- Department of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Dennis W. J. Klomp
- Department of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Chathura Kumaragamage
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Dimitri Welting
- Department of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - Peter B. Brown
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Scott McIntyre
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Terence W. Nixon
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Jeanine J. Prompers
- Department of Radiology, Imaging Division, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Henk M. De Feyter
- Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center, Yale University School of Medicine, New Haven, Connecticut, USA
| |
Collapse
|
8
|
Kusaka Y, Hasegawa T, Kaji H. Noise Reduction in Solid-State NMR Spectra Using Principal Component Analysis. J Phys Chem A 2019; 123:10333-10338. [PMID: 31682439 DOI: 10.1021/acs.jpca.9b04437] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
A noise reduction method was developed for solid-state nuclear magnetic resonance spectroscopy using multivariate analysis. Principal component analysis was first applied for cross-polarization/magic angle spinning and 13C spin-lattice relaxation measurements of solid-state nuclear magnetic resonance array spectra. The contact time of cross-polarization/magic angle spinning and the delay time in spin-lattice relaxation measurements were continuously changed to obtain a series of spectra, which were used for noise reduction using principal component analysis. The noise reduction method successfully produced spectra with improved signal-to-noise ratios. This noise reduction method shortens the measurement time and allows for detection of components with minute signals.
Collapse
Affiliation(s)
- Yasunari Kusaka
- Research & Development Institute, High-Performance Functional Plastics Company , Sekisui Chemical Co., Ltd. , Mishimagun-Shimamotocho, Osaka 618-0021 , Japan.,Institute for Chemical Research , Kyoto University , Uji, Kyoto 611-0011 , Japan
| | - Takeshi Hasegawa
- Institute for Chemical Research , Kyoto University , Uji, Kyoto 611-0011 , Japan
| | - Hironori Kaji
- Institute for Chemical Research , Kyoto University , Uji, Kyoto 611-0011 , Japan
| |
Collapse
|
9
|
Johansen DH, Sanchez-Heredia JD, Petersen JR, Johansen TK, Zhurbenko V, Ardenkjaer-Larsen JH. Cryogenic Preamplifiers for Magnetic Resonance Imaging. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:202-210. [PMID: 29377808 DOI: 10.1109/tbcas.2017.2776256] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Pursuing the ultimate limit of detection in magnetic resonance imaging (MRI) requires cryogenics to decrease the thermal noise of the electronic circuits. As cryogenic coils for MRI are slowly emerging cryogenic preamplifiers are required to fully exploit their potential. A cryogenic preamplifier operated at 77 K is designed and implemented for C imaging at 3 T (32.13 MHz), using off-the-shelves components. The design is based on a high electron mobility transistor (ATF54143) in a common source configuration. Required auxiliary circuitry for optimal cryogenic preamplifier performance is also presented consisting of a voltage regulator (noise free supply voltage and optimal power consumption), switch, and trigger (for active detuning during transmission to protect the preamplifier). A gain of 18 dB with a noise temperature of 13.7 K is achieved. Performing imaging experiments in a 3 T scanner showed an 8% increased signal-to-noise ratio from 365 to 399 when lowering the temperature of the preamplifier from 296 to 77 K while keeping the coil at room temperature. This paper thus enables the merger of cryogenic coils and preamplifiers in the hopes of reaching the ultimate limit of detection for MRI.
Collapse
|
10
|
Tayler MCD, Theis T, Sjolander TF, Blanchard JW, Kentner A, Pustelny S, Pines A, Budker D. Invited Review Article: Instrumentation for nuclear magnetic resonance in zero and ultralow magnetic field. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:091101. [PMID: 28964224 DOI: 10.1063/1.5003347] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Accepted: 08/30/2017] [Indexed: 05/22/2023]
Abstract
We review experimental techniques in our laboratory for nuclear magnetic resonance (NMR) in zero and ultralow magnetic field (below 0.1 μT) where detection is based on a low-cost, non-cryogenic, spin-exchange relaxation free 87Rb atomic magnetometer. The typical sensitivity is 20-30 fT/Hz1/2 for signal frequencies below 1 kHz and NMR linewidths range from Hz all the way down to tens of mHz. These features enable precision measurements of chemically informative nuclear spin-spin couplings as well as nuclear spin precession in ultralow magnetic fields.
Collapse
Affiliation(s)
| | - Thomas Theis
- Department of Chemistry, Duke University, Durham, North Carolina 27708, USA
| | | | | | | | - Szymon Pustelny
- Institute of Physics, Jagiellonian University, 30-348 Kraków, Poland
| | - Alexander Pines
- College of Chemistry, UC Berkeley, Berkeley, California 94720, USA
| | - Dmitry Budker
- Department of Physics, UC Berkeley, Berkeley, California 94720, USA
| |
Collapse
|
11
|
Perras FA, Sadow A, Pruski M. In Silico Design of DNP Polarizing Agents: Can Current Dinitroxides Be Improved? Chemphyschem 2017; 18:2279-2287. [DOI: 10.1002/cphc.201700299] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 06/07/2017] [Indexed: 12/18/2022]
Affiliation(s)
| | - Aaron Sadow
- US DOE Ames Laboratory Ames IA 50011 USA
- Department of Chemistry Iowa State University Ames IA 50011 USA
| | - Marek Pruski
- US DOE Ames Laboratory Ames IA 50011 USA
- Department of Chemistry Iowa State University Ames IA 50011 USA
| |
Collapse
|
12
|
Ramaswamy V, Edison AS, Brey WW. Inductively-coupled Frequency Tuning and Impedance Matching in HTS-based NMR Probes. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY : A PUBLICATION OF THE IEEE SUPERCONDUCTIVITY COMMITTEE 2017; 27:1502505. [PMID: 29038639 PMCID: PMC5639725 DOI: 10.1109/tasc.2017.2672718] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Nuclear Magnetic Resonance (NMR) probes based on High Temperature Superconducting (HTS) resonators have demonstrated significant gains in detection sensitivity. However, the widespread acceptance of this technology has been limited by some unresolved issues including the mechanical unreliability of the moveable inductive loops used to adjust tuning and matching. In order to improve reliability, we propose to implement frequency tuning and impedance matching of HTS resonators using fixed inductively coupled loops and variable capacitors. By analyzing the loss mechanisms associated with inductive loops, we predict that using a superconducting inductive loop for tuning and matching will not only improve the reliability of HTS probes, but also provide improvements in sensitivity.
Collapse
|
13
|
Spiess HW. 50th Anniversary Perspective: The Importance of NMR Spectroscopy to Macromolecular Science. Macromolecules 2017. [DOI: 10.1021/acs.macromol.6b02736] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
14
|
Sundekilde UK, Meier S. 1H–13C NMR-Based Profiling of Biotechnological Starch Utilization. Anal Chem 2016; 88:9685-9690. [DOI: 10.1021/acs.analchem.6b02555] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Ulrik K. Sundekilde
- Department
of Food Science, Aarhus University, Kirstinebjergvej 10, 5792 Årslev, Denmark
| | - Sebastian Meier
- Department
of Chemistry, Technical University of Denmark, Kemitorvet, 2800 Kgs Lyngby, Denmark
| |
Collapse
|
15
|
Krunić A, Orjala J. Application of high-field NMR spectroscopy for characterization and quantitation of submilligram quantities of isolated natural products. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2015; 53:1043-50. [PMID: 26289113 PMCID: PMC4752180 DOI: 10.1002/mrc.4304] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 06/18/2015] [Accepted: 06/27/2015] [Indexed: 05/13/2023]
Abstract
We have investigated and compared a number of sample conditions on different NMR platforms in the search of maximum SNR and optimal experiment time efficiency for structure elucidation and quantitation of natural products. Using restricted volume 3 mm Shigemi microcell assembly in conjunction with a 900 MHz NMR spectrometer equipped with a 5 mm carbon-sensitive inverse cryoprobe, it was possible to achieve a substantial increase in SNR (46-fold) as compared with a conventional room temperature 400 MHz instrument. Switching from standard 5 mm NMR tube to 3 mm Shigemi microcell assembly typically improved SNR by threefold on either 600 or 900 MHz cryoplatform. A quantitation method that relies on a calibrated residual protonated NMR solvent signal as internal standard was developed using the same hardware setup and restricted sample volume tubes. Linearity of the method spans over 3 orders of magnitude, from low microgram to milligram quantities. We successfully applied this method to quantify a low micrgram sample of paclitaxel, verified by a UV/VIS quantitation measurement.
Collapse
Affiliation(s)
- Aleksej Krunić
- Department of Medicinal Chemistry and Pharmacognosy, College of Pharmacy, University of Illinois at Chicago, Chicago, IL, 60612, USA
| | - Jimmy Orjala
- Department of Medicinal Chemistry and Pharmacognosy, College of Pharmacy, University of Illinois at Chicago, Chicago, IL, 60612, USA
| |
Collapse
|
16
|
Ivanov KL, Pravdivtsev AN, Yurkovskaya AV, Vieth HM, Kaptein R. The role of level anti-crossings in nuclear spin hyperpolarization. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2014; 81:1-36. [PMID: 25142733 DOI: 10.1016/j.pnmrs.2014.06.001] [Citation(s) in RCA: 105] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Revised: 06/11/2014] [Accepted: 06/13/2014] [Indexed: 05/22/2023]
Abstract
Nuclear spin hyperpolarization is an important resource for increasing the sensitivity of NMR spectroscopy and MRI. Signal enhancements can be as large as 3-4 orders of magnitude. In hyperpolarization experiments, it is often desirable to transfer the initial polarization to other nuclei of choice, either protons or insensitive nuclei such as (13)C and (15)N. This situation arises primarily in Chemically Induced Dynamic Nuclear Polarization (CIDNP), Para-Hydrogen Induced Polarization (PHIP), and the related Signal Amplification By Reversible Exchange (SABRE). Here we review the recent literature on polarization transfer mechanisms, in particular focusing on the role of Level Anti-Crossings (LACs) therein. So-called "spontaneous" polarization transfer may occur both at low and high magnetic fields. In addition, transfer of spin polarization can be accomplished by using especially designed pulse sequences. It is now clear that at low field spontaneous polarization transfer is primarily due to coherent spin-state mixing under strong coupling conditions. However, thus far the important role of LACs in this process has not received much attention. At high magnetic field, polarization may be transferred by cross-relaxation effects. Another promising high-field technique is to generate the strong coupling condition by spin locking using strong radio-frequency fields. Here, an analysis of polarization transfer in terms of LACs in the rotating frame is very useful to predict which spin orders are transferred depending on the strength and frequency of the B1 field. Finally, we will examine the role of strong coupling and LACs in magnetic-field dependent nuclear spin relaxation and the related topic of long-lived spin-states.
Collapse
Affiliation(s)
- Konstantin L Ivanov
- International Tomography Center, Siberian Branch of the Russian Academy of Science, Institutskaya 3a, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova 2, Novosibirsk 630090, Russia.
| | - Andrey N Pravdivtsev
- International Tomography Center, Siberian Branch of the Russian Academy of Science, Institutskaya 3a, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova 2, Novosibirsk 630090, Russia
| | - Alexandra V Yurkovskaya
- International Tomography Center, Siberian Branch of the Russian Academy of Science, Institutskaya 3a, Novosibirsk 630090, Russia; Novosibirsk State University, Pirogova 2, Novosibirsk 630090, Russia
| | - Hans-Martin Vieth
- Freie Universität Berlin, Institut für Experimentalphysik, Arnimallee 14, Berlin 14195, Germany
| | - Robert Kaptein
- Bijvoet Center for Biomolecular Research, Utrecht University, Padualaan 8, NL-3584 CH Utrecht, The Netherlands.
| |
Collapse
|
17
|
Chiwan Koo, Godley RF, McDougall MP, Wright SM, Han A. A microfluidically cryocooled spiral microcoil with inductive coupling for MR microscopy. IEEE Trans Biomed Eng 2014; 61:76-84. [PMID: 23955689 DOI: 10.1109/tbme.2013.2276770] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/06/2024]
Abstract
Magnetic resonance (MR) microscopy typically employs microcoils for enhanced local signal-to-noise ratio (SNR). Planar (surface) microcoils, in particular, offer the potential to be configured into array elements as well as to enable the imaging of extremely small samples because of the uniformity and precision provided by microfabrication techniques. Microcoils, in general, however, are copper-loss dominant, and cryocooling methods have been successfully used to improve the SNR. Cryocooling of the matching network elements, in addition to the coil itself, has shown to provide the most improvement, but can be challenging with respect to cryostat requirements, cabling, and tuning. Here we present the development of a microfluidically cryocooled spiral microcoil with integrated microfabricated parallel plate capacitors, allowing for localized cryocooling of both the microcoil and the on-chip resonating capacitor to increase the SNR while keeping the sample-to-coil distance within the most sensitive imaging range of the microcoil. Inductive coupling was used instead of a direct transmission line connection to eliminate the physical connection between the microcoil and the tuning network so that a single cryocooling microfluidic channel could enclose both the microcoil and the on-chip capacitor with minimum loss in cooling capacity. Comparisons between the cooled and uncooled cases were made via Q-factor measurements and agreed well with the theoretically achievable improvement: the cooled integrated capacitor coil with inductive coupling achieved a factor of 2.6 improvement in Q-factor over a reference coil conventionally matched and tuned with high- Q varactors and capacitively connected to the transmission line.
Collapse
|
18
|
Nakano H, Nakai T. Improved SNR of magnetic resonance microimaging using a cooled resonance circuit at 0.3T. Magn Reson Med Sci 2012; 10:259-62. [PMID: 22214912 DOI: 10.2463/mrms.10.259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Because it is noninvasive, magnetic resonance microimaging (MRMI) can be used for 3-dimensional measurement of living tissues for cell engineering. Thermal noise in the resonance circuit of the radiofrequency (RF) system of the MRMI cannot become ignored as the signal diminishes in accordance with decreasing sample size, and cooling the RF coil of the receiver circuit can effectively reduce thermal noise. We used a low temperature normal conductor circuit to reduce noise and confirmed improved signal-to-noise ratio for a conventional microimaging system at low B(0) field (0.3T) with low cost.
Collapse
Affiliation(s)
- Hiroshi Nakano
- Research Institute for Ubiquitous Energy Devices, National Institute of Advanced Industrial Science and Technology, Ikeda, Osaka, Japan.
| | | |
Collapse
|
19
|
Mizuno T, Takegoshi K. Development of a cryogenic duplexer for solid-state nuclear magnetic resonance. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2009; 80:124702. [PMID: 20059159 DOI: 10.1063/1.3263908] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
To fully appreciate sensitivity enhancement achievable by reducing thermal noise at the detection coil for nuclear magnetic resonance (NMR), a duplexer operational at low temperature is required. In this work, we developed a cryogenic duplexer that can work below 50 K using GaAs diodes and rf-microelectrical mechanical systems switches. As the observed leakage of a rf pulse (100 W and 50 micros) through the duplexer is below 1 mW, it can be used not only for NMR in liquids but also for NMR in solids. We reported recently the cryocoil magic-angle spinning (MAS) probe [T. Mizuno et al., Rev. Sci. Instrum. 79, 044706 (2008)] into which was incorporated with this duplexer and a commercial rf preamplifier, we show that signal-to-noise ratio gain of 4.0 times can be achieved for (1)H MAS-NMR by lowering the detection-coil temperature to 12 K and the temperatures for the rf preamplifier and the duplexer to 43 K.
Collapse
Affiliation(s)
- Takashi Mizuno
- JEOL Ltd., 1-2 Musashino 3-Chome, Akishima, Tokyo 196-8558, Japan.
| | | |
Collapse
|
20
|
Dóra B, Simon F. Unusual hyperfine interaction of dirac electrons and NMR spectroscopy in graphene. PHYSICAL REVIEW LETTERS 2009; 102:197602. [PMID: 19518995 DOI: 10.1103/physrevlett.102.197602] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2009] [Indexed: 05/27/2023]
Abstract
A theory of nuclear magnetic resonance (NMR) in graphene is presented. The canonical form of the electron-nucleus hyperfine interaction is strongly modified by the linear electronic dispersion. The NMR shift and spin-lattice relaxation time are calculated as a function of temperature, chemical potential, and magnetic field, and three distinct regimes are identified: Fermi-, Dirac-gas, and extreme quantum limit behaviors. A critical spectrometer assessment shows that NMR is within reach for fully 13C enriched graphene of reasonable size.
Collapse
Affiliation(s)
- Balázs Dóra
- Max-Planck-Institut für Physik Komplexer Systeme, Nöthnitzer Strasse 38, 01187 Dresden, Germany
| | | |
Collapse
|
21
|
Mizuno T, Hioka K, Fujioka K, Takegoshi K. Development of a magic-angle spinning nuclear magnetic resonance probe with a cryogenic detection system for sensitivity enhancement. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:044706. [PMID: 18447543 DOI: 10.1063/1.2912946] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A novel nuclear magnetic resonance (NMR) probe for high-resolution solid-state NMR has been developed. In this probe, temperature of the detection coil is kept at cryogenic temperature (approximately 12 K) for sensitivity enhancement, which is achieved not only by suppression of thermal noise but also by increment of a Q factor of the coil. A marked feature of this probe is that a sample rotating at magic angle is thermally isolated from the cryogenic system in order to realize high-resolution solid-state NMR measurement at various sample temperatures. We call this system as cryocoil magic-angle spinning (cryocoil MAS). (1)H MAS NMR with the coil temperature of approximately 20 K was successfully observed for solid adamantane rotating at room temperature, and signal-to-noise increment due to this cryocoil approach was confirmed.
Collapse
Affiliation(s)
- Takashi Mizuno
- JEOL Ltd., 1-2 Musashino 3-Chome, Akishima, Tokyo 196-8558, Japan.
| | | | | | | |
Collapse
|
22
|
Voehler MW, Collier G, Young JK, Stone MP, Germann MW. Performance of cryogenic probes as a function of ionic strength and sample tube geometry. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2006; 183:102-9. [PMID: 16949320 PMCID: PMC4852285 DOI: 10.1016/j.jmr.2006.08.002] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2006] [Revised: 08/06/2006] [Accepted: 08/09/2006] [Indexed: 05/11/2023]
Abstract
The pursuit for more sensitive NMR probes culminated with development of the cryogenic cooled NMR probe. A key factor for the sensitivity is the overall resistance of RF circuitry and sample. Lowering the coil temperature to approximately 25 K and the use of superconducting coil material has greatly reduced the resistance contribution of the hardware. However, the resistance of a salty sample remains the same and evolves as the major factor determining the signal-to-noise ratio. Several approaches have been proposed to reduce the resistance contribution of the sample. These range from encapsulating proteins in a water cavity formed by reverse micelles in low viscosity fluids to the optimal selection of low mobility, low conductivity buffer ions. Here we demonstrate that changing the sample diameter has a pronounced effect on the sample resistance and this results in dramatic improvements of the signal-to-noise ratio and shorter pi/2 pulses. We determined these parameters for common 5 mm NMR tubes under different experimental conditions and compared them to the 2, 3 and 4 mm tubes, in addition, 5mm Shigemi tubes were included since these are widely used. We demonstrate benefits and applicability of studying NMR samples with up to 4M salt concentrations in cryogenic probes. Under high salt conditions, best results in terms of short pi/2 pulses and high signal-to-noise ratios are obtained using 2 or 3mm NMR tubes, especially when limited sample is available. The 4 mm tube is preferred when sample amounts are abundant at intermediate salt conditions.
Collapse
Affiliation(s)
- Markus W. Voehler
- Department of Chemistry, Center in Molecular Toxicology, Vanderbilt University, Nashville, TN 37235, USA
| | - Galen Collier
- Georgia State University, Departments of Chemistry and Biology, Atlanta, GA 30303, USA
| | - John K. Young
- Mississippi State University, Department of Chemistry, MS 39762, USA
| | - Michael P. Stone
- Department of Chemistry, Center in Molecular Toxicology, Vanderbilt University, Nashville, TN 37235, USA
| | - Markus W. Germann
- Georgia State University, Departments of Chemistry and Biology, Atlanta, GA 30303, USA
| |
Collapse
|
23
|
Krishnan VV. Radiation damping in microcoil NMR probes. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2006; 179:294-8. [PMID: 16427795 DOI: 10.1016/j.jmr.2005.12.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2005] [Revised: 12/15/2005] [Accepted: 12/23/2005] [Indexed: 05/06/2023]
Abstract
Radiation damping arises from the field induced in the receiver coil by large bulk magnetization and tends to selectively drive this magnetization back to equilibrium much faster than relaxation processes. The demand for increased sensitivity in mass-limited samples has led to the development of microcoil NMR probes that are capable of obtaining high quality NMR spectra with small sample volumes (nL-microL). Microcoil probes are optimized to increase sensitivity by increasing either the sample-to-coil ratio (filling factor) of the probe or quality factor of the detection coil. Though radiation damping effects have been studied in standard NMR probes, these effects have not been measured in the microcoil probes. Here a systematic evaluation of radiation damping effects in a microcoil NMR probe is presented and the results are compared with similar measurements in conventional large volume samples. These results show that radiation-damping effects in microcoil probe is much more pronounced than in 5 mm probes, and that it is critically important to optimize NMR experiments to minimize these effects. As microcoil probes provide better control of the bulk magnetization, with good RF and B0 inhomogeneity, in addition to negligible dipolar field effects due to nearly spherical sample volumes, these probes can be used exclusively to study the complex behavior of radiation damping.
Collapse
Affiliation(s)
- V V Krishnan
- Biosciences Directorate, Lawrence Livermore National Laboratory, Livermore, CA 94551, USA.
| |
Collapse
|
24
|
Bieri S, Varesio E, Veuthey JL, Muñoz O, Tseng LH, Braumann U, Spraul M, Christen P. Identification of isomeric tropane alkaloids from Schizanthus grahamii by HPLC-NMR with loop storage and HPLC-UV-MS/SPE-NMR using a cryogenic flow probe. PHYTOCHEMICAL ANALYSIS : PCA 2006; 17:78-86. [PMID: 16634283 DOI: 10.1002/pca.889] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Two fully automated HPLC-NMR methods are reported and compared for the structure elucidation of four isomeric tropane alkaloids from the stem-bark of an endemic Chilean plant, Schizanthus grahamii Gill. (Solanaceae). The first approach interfaced a conventional HPLC column to NMR by means of a loop storage unit. After elution with a mobile phase consisting of deuterated water and standard protonated organic solvents, the separated analytes were momentarily stored in a loop cassette and then transferred one-at-a-time to the NMR flow probe for measurements. The second strategy combined HPLC with parallel ion-trap MS detection and NMR spectroscopy using an integrated solid-phase extraction (SPE) unit for post-column analyte trapping. The SPE cartridges were dried under a gentle stream of nitrogen and analytes were sequentially eluted and directed to a cryogenically cooled flow-probe with an NMR-friendly solvent. The structures of the four isomeric alkaloids, 3alpha-senecioyloxy-7beta-hydroxytropane, 3alpha-hydroxy-7beta-angeloyloxytropane, 3alpha-hydroxy-7beta-tigloyloxytropane and 3alpha-hydroxy-7beta-senecioyloxytropane, were unambiguously determined by combining NMR assignments with MS data.
Collapse
Affiliation(s)
- Stefan Bieri
- Laboratory of Pharmaceutical Analytical Chemistry, School of Pharmaceutical Sciences EPGL, University of Geneva, 20 Bd d'Yvoy, 1211 Geneva 4, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Nelson BN, Schieber LJ, Barich DH, Lubach JW, Offerdahl TJ, Lewis DH, Heinrich JP, Munson EJ. Multiple-sample probe for solid-state NMR studies of pharmaceuticals. SOLID STATE NUCLEAR MAGNETIC RESONANCE 2006; 29:204-13. [PMID: 16246531 DOI: 10.1016/j.ssnmr.2005.08.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2005] [Indexed: 05/04/2023]
Abstract
Solid-state NMR spectroscopy (SSNMR) is an extremely powerful technique for the analysis of pharmaceutical dosage forms. A major limitation of SSNMR is the number of samples that can be analyzed in a given period of time. A solid-state magic-angle spinning (MAS) probe that can simultaneously acquire up to seven SSNMR spectra is being developed to increase throughput/signal-to-noise ratios. A prototype probe incorporating two MAS modules has been developed and spectra of ibuprofen and aspirin have been acquired simultaneously. This version is limited to being a two-module probe due to large amounts of space required for the tuning elements located next to the MAS modules. A new probe design incorporating coaxial transmission lines and smaller MAS modules has been constructed. This probe allows for close proximity of the MAS modules (within 3 cm), adequate proton decoupling power (>50 kHz), and the capability of remote tuning and sample changing. Spectra of hexamethylbenzene (HMB) have been acquired and show signal-to-noise ratios comparable to existing SSNMR probes. Adamantane line widths are also comparable to conventional probe technology. Decoupling powers of 70 kHz have been achieved using a MAS module suitable for 3 cm spacing between modules. Remote tuning has also been achieved with this new coaxial transmission line design. This probe design can be easily scaled to incorporate multiple MAS modules, which is a limitation of the previous design. The number of modules that can be incorporated is only limited by the number of transmission lines that will fit in a cross-sectional diameter of the bore and the axial field length of the magnet.
Collapse
Affiliation(s)
- Benjamin N Nelson
- Department of Pharmaceutical Chemistry, University of Kansas, 2095 Constant Avenue, Lawrence, KS 66047, USA
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Exarchou V, Krucker M, van Beek TA, Vervoort J, Gerothanassis IP, Albert K. LC-NMR coupling technology: recent advancements and applications in natural products analysis. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2005; 43:681-7. [PMID: 16049952 DOI: 10.1002/mrc.1632] [Citation(s) in RCA: 90] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
An overview of recent advances in nuclear magnetic resonance (NMR) coupled with separation technologies and their application in natural product analysis is given and discussed. The different modes of LC-NMR operation are described, as well as how technical improvements assist in establishing LC-NMR as an important tool in the analysis of plant-derived compounds. On-flow, stopped-flow and loop-storage procedures are mentioned, together with the new LC-SPE-NMR configuration. The implementation of mass spectrometry in LC-NMR is also useful on account of the molecular weight and fragmentation information that it provides, especially when new plant species are studied. Cryogenic technology and capillary LC-NMR are the other important recent developments. Since the plant kingdom is endless in producing potential drug candidates, development and optimization of LC-NMR techniques convert the study of natural products to a less-time-consuming task, speeding up identification.
Collapse
|
27
|
Poirier-Quinot M, Ginefri JC, Ledru F, Fornes P, Darrasse L. Preliminary ex vivo 3D microscopy of coronary arteries using a standard 1.5 T MRI scanner and a superconducting RF coil. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2005; 18:89-95. [PMID: 15711851 DOI: 10.1007/s10334-004-0097-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2004] [Revised: 12/01/2004] [Accepted: 12/01/2004] [Indexed: 11/28/2022]
Abstract
This paper presents the feasibility of three-dimensional (3D) magnetic resonance (MR) histology of atheromatous coronary lesions in the entire human heart ex vivo using a standard 1.5 T scanner and a 12 mm high-temperature superconducting (HTS) surface coil. The HTS coil was a five-turn transmission-line resonator operated at 77 K, affording a signal-to-noise ratio (SNR) gain of about ninefold as compared to a similar, room-temperature copper coil. Local microscopy at the surface of an explanted, entire heart was achieved by a 3D spoiled gradient echo sequence and assessed by comparison with conventional histology. One hundred and twenty four adjacent cross sections of the coronary artery, with voxels of 59 x 59 x 100 microm3 and an SNR of about 20, were obtained in 25 min. Consecutive data sets were combined to reconstruct extended views along the artery. Compared to histology, MR microscopy allowed precise nondestructive 3D depiction of the architecture of the atheromatous plaques. This is the first report of microscopic details (less than 10(-3) mm3 voxels) of diseased arteries obtained in an entire human heart preserving the arterial integrity and the spatial geometry of atheroma. This noninvasive microscopy approach using a HTS surface coil might be applied in vivo to study the architecture and components of superficial human structures, using routine MR scanners.
Collapse
|
28
|
McDougall MP, Wright SM. 64-channel array coil for single echo acquisition magnetic resonance imaging. Magn Reson Med 2005; 54:386-92. [PMID: 16032696 DOI: 10.1002/mrm.20568] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A 64-channel array coil for magnetic resonance imaging (MRI) has been designed and constructed. The coil was built to enable the testing of a new imaging method, single echo acquisition (SEA) MRI, in which an independent full image is acquired with every echo. This is accomplished by entirely eliminating phase encoding and instead using the spatial information obtained from an array of very narrow, long, parallel coils. The planar pair element design proved to be key in achieving well-localized field sensitivity patterns and isolated elements, the crucial requirements for performing SEA. The matching and tuning of the array elements were accomplished on the coil array printed circuit board using varactor diodes biased over the RF lines. The array was successfully used to obtain SEA images as well as conventional partially parallel images at unprecedented acceleration factors.
Collapse
Affiliation(s)
- Mary Preston McDougall
- Department of Electrical Engineering, Texas A&M University, College Station, Texas 77845, USA.
| | | |
Collapse
|
29
|
Bringmann G, Feineis D. Stress-related polyketide metabolism of Dioncophyllaceae and Ancistrocladaceae. JOURNAL OF EXPERIMENTAL BOTANY 2001; 52:2015-2022. [PMID: 11559737 DOI: 10.1093/jexbot/52.363.2015] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The discovery of a novel biosynthetic pathway to isoquinoline alkaloids is described. The naphthylisoquinoline alkaloid dioncophylline A, one of the most prominent representatives of a new class of structurally and pharmacologically intriguing secondary metabolites, is shown to originate from acetate units, both molecular halves, the isoquinoline part and the naphthalene portion, being formed from identical polyketide precursors. All other tetrahydroisoquinoline alkaloids previously investigated, ultimately originate from aromatic amino acids. The novel pathway to isoquinoline alkaloids (hence acetogenic) was proved by feeding experiments with (13)C-labelled precursors administered to callus cultures of Triphyophyllum peltatum (Dioncophyllaceae), followed by NMR investigations using the potent cryoprobe methodology. The new pathway is largely stress-sensitive: upon exposure to chemical, biotic or physical stress, T. peltatum stops producing the isoquinoline part, so that the naphthalene moiety accumulates in the chemical form of naphthoquinones like plumbagin and droserone and the chiral tetralone isoshinanolone.
Collapse
Affiliation(s)
- G Bringmann
- Institut für Organische Chemie der Universität Würzburg, Am Hubland, D-97074 Würzburg, Germany.
| | | |
Collapse
|