1
|
Sun X, Berthiller J, Trouillas P, Derex L, Diallo L, Hanss M. Early fibrinogen degradation coagulopathy: A predictive factor of parenchymal hematomas in cerebral rt-PA thrombolysis. J Neurol Sci 2015; 351:109-114. [DOI: 10.1016/j.jns.2015.02.048] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2014] [Revised: 02/26/2015] [Accepted: 02/27/2015] [Indexed: 10/23/2022]
|
2
|
MONREAL L, ANGLES ANNAM, MONREAL M, ESPADA YVONNE, MONASTERIO J. Changes in haemostasis in endurance horses: detection by highly sensitive ELISA-tests. Equine Vet J 2010. [DOI: 10.1111/j.2042-3306.1995.tb04903.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
3
|
Paniccia R, Prisco D, Bandinelli B, Fedi S, Giusti B, Pepe G, Abbate R. Plasma and serum levels of D-dimer and their correlations with other hemostatic parameters in pregnancy. Thromb Res 2002; 105:257-62. [PMID: 11927132 DOI: 10.1016/s0049-3848(02)00022-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The measurement of D-dimer in serum samples (s-DD) after standardized coagulation has been reported as a possible single global test for fibrinolysis in unstimulated conditions in healthy subjects and in patients with ischemic heart disease and with different metabolic disorders. No study has been performed on the use of this test in pregnancy, a condition characterized by physiological changes both in coagulation and in fibrinolysis. In this preliminary study, we have evaluated in 28 women with physiological pregnancy and in 23 comparable controls s-DD and a number of markers of coagulation and fibrinolysis. In nonpregnant women s-DD showed a good correlation with fibrinolytic parameters [euglobulin lysis time (ELT) and type 1 inhibitor of tissue plasminogen activator (PAI-1) act: P<.01; tissue plasminogen activator (t-PA) ag and PAI-1 ag: P<.05], confirming previous data, whereas in pregnant women no correlation was observed. Plasma DD (pls-DD) and s-DD levels were not correlated either in pregnant or in control women. s-DD levels were significantly higher than pls-DD in controls and in 15/28 pregnant women whose pls-DD values were in normal range or mildly increased (<110 ng/ml; P<.05), whereas in the 13 pregnant women with high pls-DD levels no significant differences were found between pls-DD and s-DD levels. Because in pregnancy high pls-DD levels are frequently found, possibly only as a consequence of enhanced clotting activation and fibrin deposition, we cannot exclude that D-dimer measured in serum reflects, at least in part, cross-linked fibrin degradation products (FDP) already present in blood before standardized coagulation. Therefore, D-dimer generated in vitro would account only in part for s-DD measured. This can explain why in pregnant women, differently from controls, s-DD does not correlate with fibrinolytic parameters. In conclusion, this preliminary study indicates that baseline pls-DD levels may be an important potential confounder in the interpretation of s-DD results in pregnant women and that s-DD cannot be proposed as a tool for a rapid evaluation of fibrinolytic activity in pregnancy.
Collapse
Affiliation(s)
- Rita Paniccia
- Dipartimento di Area Critica Medico-Chirurgica, Sezione di Clinica Medica Generale e Cliniche Specialistiche, University of Florence, Viale Morgagni, 85, 50134, Italy.
| | | | | | | | | | | | | |
Collapse
|
4
|
Bayes-Genis A, Mateo J, Santaló M, Oliver A, Guindo J, Badimon L, Martínez-Rubio A, Fontcuberta J, Schwartz RS, De Luna AB. D-Dimer is an early diagnostic marker of coronary ischemia in patients with chest pain. Am Heart J 2000; 140:379-84. [PMID: 10966534 DOI: 10.1067/mhj.2000.108823] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Chest pain is a frequent symptom in the emergency department and often presents a diagnostic challenge. Because coronary thrombosis is a hallmark of acute ischemic syndromes, the substrates of the coagulation and fibrinolysis cascades may be markers of coronary ischemia. The objective of this study was to determine the diagnostic value of several hemostatic markers in patients presenting to the emergency department (ED) with chest pain syndromes. METHODS Two hundred fifty-seven consecutive patients with acute chest pain were studied in this prospective study conducted in an urban ED. D-Dimer levels were measured at admission to the ED in all patients. We also measured thrombin-antithrombin complexes, prothrombin fragment 1+2, activated factor VII, and fibrinogen. We used regression analysis to estimate the likelihood of myocardial infarction and the diagnostic value of D-dimer. RESULTS D-Dimer and fibrinogen levels were significantly higher in patients with acute ischemic events (myocardial infarction and unstable angina) than in nonischemic patients (P <.01 and P =.02, respectively). The other hemostatic markers were not significantly elevated in patients with ischemic events. D-Dimer level >500 microg/L had an independent diagnostic value for myocardial infarction and increased the diagnostic sensitivity of the electrocardiogram and history from 73% to 92%. CONCLUSION D-Dimer, an expression of ongoing thrombus formation and lysis, is a marker of substantial incremental value for the early diagnosis of acute coronary syndromes presenting with chest pain. It adds independent information to the traditional assessment for myocardial infarction. D-Dimer can be incorporated into clinical decision models in the ED.
Collapse
Affiliation(s)
- A Bayes-Genis
- Departments of Cardiology and Cardiac Surgery, Hematology, Hospital de la Santa Creu I Sant Pau, Barcelona, Spain
| | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Monreal L, Anglés A, Espada Y, Monasterio J, Monreal M. Hypercoagulation and hypofibrinolysis in horses with colic and DIC. Equine Vet J 2000:19-25. [PMID: 11202377 DOI: 10.1111/j.2042-3306.2000.tb05329.x] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Changes in haemostasis in horses with colic were assessed by using specific and sensitive markers of coagulation and fibrinolysis activity. Blood samples from 41 horses with severe colic and from 30 healthy control horses were tested. Diagnosis of DIC was based on the findings of at least 3 of 6 abnormalities: thrombocytopenia, prolonged clotting times (PT and APTT), increased polyclonal FDPs, decreased fibrinogen and decreased AT-III activity. Plasma thrombin-antithrombin III complexes (TAT), monoclonal fibrin degradation products fragment D (D-dimer) and monoclonal fibrinogen degradation products (FgDP) were also tested by using ELISA kits. DIC was diagnosed in 16 of 41 horses with colic. Compared to control and non-DIC colic values, TAT was significantly (P < 0.000) greater in horses with colic and DIC (Control group, mean +/- s.d. 2.6 +/- 2; non-DIC colic group, 7.5 +/- 9, and DIC colic group, 30.9 +/- 36 ng/ml). Also, D-dimer was significantly (P < 0.000) less in the DIC group when compared to control and non-DIC colic values (mean +/- s.d. 677 +/- 119, 682 +/- 220 and 399 +/- 234 ng/ml, respectively). Compared to non-DIC colic values, FgDP was significantly (P < 0.05) lower in the DIC group (363 +/- 111, 437 +/- 230 and 293 +/- 187 ng/ml respectively). Both PT and APTT showed a significant positive correlation with TAT. DIC was more common among nonsurvivors and horses with ischaemic bowel. We conclude that a hypercoagulative state was detected in horses with colic, which was stronger in horses with colic and DIC. Hypofibrinolysis was present only in horses with DIC. Therefore, marked hypercoagulation together with hypofibrinolysis are associated with DIC in horses.
Collapse
Affiliation(s)
- L Monreal
- Unitat Experimental de Trombosi, Dept. Patologia Mèdica, Facultat de Veterinària, Universitat Autònoma de Barcelona, 08193-Barcelona, Spain
| | | | | | | | | |
Collapse
|
6
|
Prisco D, Paniccia R, Bandinelli B, Liotta AA, Fedi S, Giusti B, Pepe G, Abbate R. Effect of temperature and incubation time on D-dimer serum levels in healthy subjects. Thromb Res 2000; 97:513-7. [PMID: 10704663 DOI: 10.1016/s0049-3848(99)00204-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- D Prisco
- Istituto di Clinica Medica Generale e Cardiologia, University of Florence, Florence, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Bach-Gansmo ET, Strand O, Godal HC, Wisløff F, Skjønsberg OH. Discrepancy between latex and ELISA D-dimer values in sepsis may be caused by human neutrophil elastase. Thromb Res 1997; 86:141-52. [PMID: 9175235 DOI: 10.1016/s0049-3848(97)00057-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
We have recently shown that D-dimers are degraded by human neutrophil elastase (HNE) in vitro, causing rapid decrease in the D-dimer levels measured by a Latex test, but not with an ELISA test employing the same monoclonal antibody against D-dimer. To see if such discrepant D-dimer concentrations occurred in patients with high HNE concentration, we examined 80 plasma samples from 8 patients with sepsis with a Latex and an ELISA test and calculated the ratio between the D-dimer values obtained with the two tests. Twenty healthy pregnant and twenty pre-eclamptic patients, who are known to have raised D-dimer but low HNE concentrations, were chosen as controls. HNE levels were estimated by determining the HNE-alpha 1-proteinase inhibitor complex (HNE-A1PI) concentration. HNE-A1PI concentration was increased in sepsis patients compared with pre-eclamptic patients (p < 0.0005) and healthy pregnant women (p < 0.0005). In sepsis patients, the D-dimer results were skewed towards lower ratios between Latex and ELISA values compared to pre-eclamptic patients (p = 0.008) and healthy pregnant women (p = 0.0001). In plasma samples from patients with the largest discrepancy between Latex and ELISA D-dimer values, Western blotting with immunostaining indicated degradation of D-dimers to D-like fragments similar to those observed following degradation of cross-linked fibrin by HNE in vitro. We conclude that in sepsis patients there is a marked discrepancy between Latex and ELISA D-dimer values that may be caused by HNE. In such patients Latex D-dimer assays may cause severe underestimation of fibrinolysis.
Collapse
Affiliation(s)
- E T Bach-Gansmo
- Department of Pulmonary Medicine, Ullevål Hospital, University of Oslo, Norway.
| | | | | | | | | |
Collapse
|
8
|
Bach-Gansmo ET, Halvorsen S, Godal HC, Skjonsberg OH. D-dimers are degraded by human neutrophil elastase. Thromb Res 1996; 82:177-86. [PMID: 9163071 DOI: 10.1016/0049-3848(96)00064-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
To see if D-dimers were degraded by human neutrophil elastase (HNE), cross-linked fibrin was obtained by adding thrombin to purified fibrinogen in the presence of calcium ions and factor XIII, and the fibrin clot subsequently degraded by plasmin. Thereafter, the supernatant containing fibrin degradation products was removed and incubated with HNE. D-dimer levels were measured by two rapid semiquantitative tests, a latex agglutination test and the Nycocard immunofiltration test, and a quantitative ELISA-method. With increasing incubation time, D-dimer levels as measured by the latex and Nycocard tests rapidly decreased and subsequently became undetectable, while the ELISA D-dimer values remained essentially unchanged. By using SDS-electrophoresis and immunoblotting, the degradation of plasmic derivatives of cross-linked fibrin by fiNE was visualised. We conclude that in a purified system, D-dimers formed during plasmin mediated lysis of cross linked fibrin are further degraded by HNE. Such HNE degradation reduces the D-dimer concentration as measured by rapid semiquantitive tests, and may be partly responsible for discrepant results when using different D-dimer assays.
Collapse
Affiliation(s)
- E T Bach-Gansmo
- Department of Pulmonary Medicine, Ulleval Hospital, University of Oslo, Norway
| | | | | | | |
Collapse
|
9
|
Bongard O, Wicky J, Peter R, Simonovska S, Vogel JJ, de Moerloose P, Reber G, Bonameaux H. D-dimer plasma measurement in patients undergoing major hip surgery: use in the prediction and diagnosis of postoperative proximal vein thrombosis. Thromb Res 1994; 74:487-93. [PMID: 8085249 DOI: 10.1016/0049-3848(94)90269-0] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Plasma D-Dimer (DD), a highly sensitive marker of venous thromboembolism, was measured with an ELISA assay preoperatively and on the 12th postoperative day in 173 patients undergoing major hip surgery (78 elective arthroplasties and 95 operations for fractures). Proximal deep venous thrombosis (DVT) was detected by systematic compression venous ultrasonography on the 12th postoperative day in 12 (7%) patients. In one additional case, proximal DVT was diagnosed by venography. Preoperative DD level was significantly higher in patients with fracture than in patients undergoing elective arthroplasty. At a cutoff of 500 micrograms/L as determined by ROC curve analysis, the sensitivity, specificity, positive and negative predictive values of the pre-operative DD concentration for the development of subsequent proximal DVT were 93%, 23%, 36% and 96%, respectively. The diagnostic exclusion value of the DD measurement on the 12th postoperative day was similar but for a cutoff of 2000 micrograms/L. These data suggest that plasma DD measurement might be useful to predict and diagnose proximal DVT following major hip surgery.
Collapse
Affiliation(s)
- O Bongard
- Division of Angiology and Hemostasis, University Hospital of Geneva, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Raimondi P, Bongard O, de Moerloose P, Reber G, Waldvogel F, Bounameaux H. D-dimer plasma concentration in various clinical conditions: implication for the use of this test in the diagnostic approach of venous thromboembolism. Thromb Res 1993; 69:125-30. [PMID: 8465271 DOI: 10.1016/0049-3848(93)90009-d] [Citation(s) in RCA: 76] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Plasma measurement of D-Dimer (DD) represents a definite aid in the diagnostic approach of outpatients with suspected venous thromboembolism (VTE). However, the high sensitivity (about 95%) of the test which allows to rule out VTE when concentrations are below a given cutoff (500 micrograms/L as measured by the ELISA technique) is counterbalanced by a poor specificity (about 40%). Because the specificity might even be lower in patients who are hospitalized we determined the DD plasma concentration in 255 patients who were consecutively admitted in general internal medicine wards with various pathological conditions. The proportion of patients who had DD levels below the cutoff of 500 micrograms/L was 6% (1/18) in patients with VTE and 22% (52/237) in hospitalized patients without VTE: the figure was 21% in patients with pulmonary infections, 14% in patients with other infections, 11% in patients with neoplastic diseases, 34% in patients with coronary or cerebrovascular disease, 19% in patients with cardiac failure, 69% in patients with rheumatologic disease and in 16% in subjects with miscellaneous clinical conditions. The high rate of elevated plasma DD in hospitalized patients questions the usefulness of this test in the diagnostic approach of VTE in aged patients who present with concomitant disease like infections, neoplasia, cardiac failure and many other pathological conditions, except rheumatologic affections and coronary or cerebrovascular diseases.
Collapse
Affiliation(s)
- P Raimondi
- Department of Medicine, University Hospital of Geneva, Switzerland
| | | | | | | | | | | |
Collapse
|
11
|
Bakker CM, Metselaar HJ, Groenland TN, Gomes MJ, Knot EA, Hesselink EJ, Schalm SW, Stibbe J, Terpstra OT. Increased tissue-type plasminogen activator activity in orthotopic but not heterotopic liver transplantation: the role of the anhepatic period. Hepatology 1992; 16:404-8. [PMID: 1639350 DOI: 10.1002/hep.1840160219] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The major cause of the increased tissue-type plasminogen activator activity during orthotopic liver transplantation is still unclear. Both the lack of hepatic clearance of tissue-type plasminogen activator in the anhepatic period and increased endothelial release from the graft on reperfusion have been proposed as the major causes. Heterotopic liver transplantation avoids the resection of the host liver and is a useful model to help differentiate between these two possibilities. In this study the fibrinolytic system was evaluated in 10 orthotopic liver transplantations, 18 heterotopic liver transplantations and a control group of 10 partial hepatic resections. A marked increment in tissue-type plasminogen activator activity, from 0.2 to 5.2 IU/ml (p less than 0.02), was observed during the anhepatic period of orthotopic liver transplantation, which rapidly normalized after reperfusion. In contrast, tissue-type plasminogen activator activity levels remained normal in heterotopic liver transplantation and partial hepatic resections. In orthotopic liver transplantation and in heterotopic liver transplantation no increase occurred in tissue-type plasminogen activator activity after reperfusion. The first venous hepatic outflow after reperfusion did not contain elevated tissue-type plasminogen activator activity levels. Plasma degradation products of fibrin and fibrinogen increased during the anhepatic period of orthotopic liver transplantation (from 2.60 to 8.80 micrograms/ml [p less than 0.008] and from 0.40 to 1.60 micrograms/ml [p less than 0.04], respectively) and remained elevated thereafter. In heterotopic liver transplantation and partial hepatic resections these levels remained low. In conclusion, the lack of hepatic clearance during the anhepatic period is probably the most important factor in the evolution of increased tissue-type plasminogen activator activity during orthotopic liver transplantation.
Collapse
Affiliation(s)
- C M Bakker
- Department of Internal Medicine, University Hospital Dijkzigt, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Tanswell P, Tebbe U, Neuhaus KL, Gläsle-Schwarz L, Wojcik J, Seifried E. Pharmacokinetics and fibrin specificity of alteplase during accelerated infusions in acute myocardial infarction. J Am Coll Cardiol 1992; 19:1071-5. [PMID: 1372625 DOI: 10.1016/0735-1097(92)90297-z] [Citation(s) in RCA: 81] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Pharmacokinetics and fibrin specificity of alteplase (recombinant tissue-type plasminogen activator) were determined in 10 patients with acute myocardial infarction undergoing an accelerated infusion regimen during the alteplase/anistreplase patency study (TAPS). Fifteen milligrams of alteplase was administered as an intravenous bolus injection, followed by infusions of 50 mg over 30 min and 35 mg over a further 60 min. Mean steady state plasma concentrations of alteplase during the initial 30 min were 3.2 +/- 0.84 micrograms/ml, measured immunochemically, and 2.1 +/- 0.23 micrograms/ml, measured using a functional activity assay. These values were 45% and 51% higher, respectively, than those during the standard infusion schedule (p less than 0.01). However, the predominant plasma half-life determined by model fitting based on either assay (3.3 to 3.5 min) was unaltered compared with the standard regimen. Maximal concentrations of fibrin and fibrinogen degradation products were 5.1 +/- 2.2 and 1.9 +/- 1.1 micrograms/ml, respectively. Plasminogen decreased to 70% and alpha 2-antiplasmin to 35% of values before infusion. The results indicate that 1) improved coronary patency rates during "front-loaded" infusions can be rationalized in terms of higher plasma concentrations of both free and immunoreactive alteplase, 2) kinetic variables are comparable with those of other dosing strategies, and 3) fibrin specificity is not diminished relative to that of the standard infusion regimen.
Collapse
Affiliation(s)
- P Tanswell
- Department of Pharmacokinetics and Metabolism, Universität Ulm, Germany
| | | | | | | | | | | |
Collapse
|
13
|
Bounameaux H, Cirafici P, de Moerloose P, Schneider PA, Slosman D, Reber G, Unger PF. Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism. Lancet 1991; 337:196-200. [PMID: 1670841 DOI: 10.1016/0140-6736(91)92158-x] [Citation(s) in RCA: 202] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The potential of plasma measurement of D-dimer (DD), a specific derivative of crosslinked fibrin, for diagnosis or exclusion of pulmonary embolism was investigated in a prospective series of 171 consecutive patients who attended an emergency department with suspected pulmonary embolism. The diagnosis was made or excluded by means of a clinical decision-making process which included clinical evaluation, ventilation-perfusion (VQ) lung scan, and, as indicated, pulmonary angiography, venography, or non-invasive examination of the leg veins. Pulmonary embolism was diagnosed by this process in 55 (32%) of 170 patients with sufficient data. All but 1 of these 55 patients had a DD concentration of 500 micrograms/l or above. The sensitivity and specificity of this cutoff concentration for the presence of pulmonary embolism were 98% and 39%, respectively, which give positive and negative predictive values of 44% and 98%. Among the 115 patients (68%) who had inconclusive VQ scans, 31 were diagnosed as having pulmonary embolism. 29 of the remaining 84 patients without pulmonary embolism had DD concentrations below 500 micrograms/l, which means that further diagnostic procedures could have been avoided in a quarter of the patients with inconclusive VQ scans. The sensitivity of the plasma measurement of DD remained high even 3 and 7 days after presentation (96% and 93%). Plasma measurement of DD therefore has a definite place in the diagnostic procedure for suspected acute pulmonary embolism in attenders at emergency departments: a concentration below 500 micrograms/l rules out the diagnosis.
Collapse
Affiliation(s)
- H Bounameaux
- Department of Medicine, University Hospital of Geneva, Switzerland
| | | | | | | | | | | | | |
Collapse
|
14
|
Eisenberg PR, Jaffe AS, Stump DC, Collen D, Bovill EG. Validity of enzyme-linked immunosorbent assays of cross-linked fibrin degradation products as a measure of clot lysis. Circulation 1990; 82:1159-68. [PMID: 2119264 DOI: 10.1161/01.cir.82.4.1159] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Concentrations of cross-linked fibrin degradation products (XL-FDPs) in plasma, measured by enzyme-linked immunosorbent assays (ELISAs) based on monoclonal antibodies (MAbs) raised against fragment D-dimer of cross-linked fibrin, increase when patients are given fibrinolytic agents. Whether XL-FDPs derive from circulating cross-linked fibrin polymers in plasma, compared with clot-associated fibrin, has been questioned because increases in XL-FDP are measured by some assays after fibrinolysis in vitro in the absence of clot. We characterized the source of XL-FDP immunoreactivity in plasma of patients with acute myocardial infarction and ischemic heart disease and the response to plasminogen activation in vitro induced by pharmacological concentrations of tissue-type plasminogen activator (t-PA) and streptokinase. XL-FDPs were measured with two different ELISA. One, "pan-specific tag ELISA," was based on a capture MAb specific for XL-FDP and a tag MAb that recognizes an epitope exposed in the fragment D region of both fibrin and fibrinogen, whereas the other, "fibrin-specific tag ELISA," was based on a capture and tag MAbs both specific for fibrin. After plasminogen activation was induced in vitro in plasma from patients with myocardial infarction, increased concentrations of XL-FDP were measured by the pan-specific tag ELISA; however, concentrations measured with the fibrin-specific tag ELISA were not increased. To determine the mechanism for this discrepancy, plasma was subjected to immunoadsorption with a MAb specific for fragment D-dimer before and after in vitro activation of the fibrinolytic system and immunoblotting with a fragment D-dimer-specific MAb and with the pan-specific MAb. Increased concentrations of fragment D-dimer, as well as fibrinogen fragment D at high concentrations, were recognized by the specific MAb. Non-cross-linked fragments were also shown by immunoblotting with the pan-specific MAb to coprecipitate with cross-linked fibrin fragments. This suggested the increased concentrations of XL-FDP measured by the pan-specific tag ELISA after in vitro activation of the fibrinolytic system were due to detection of non-cross-linked fibrinogen fragments. However, fibrin fragment D-dimer concentrations were found to increase in plasma of 15 patients given t-PA for acute myocardial infarction. We conclude fragment D-dimer in plasma of patients during thrombolysis does not originate from circulating soluble cross-linked fibrin but rather is a marker of solid-phase fibrin dissolution, which may be quantitated with assays based on capture and tag antibodies that do not detect fibrinogen or its degradation products.
Collapse
Affiliation(s)
- P R Eisenberg
- Cardiovascular Division, Washington University School of Medicine, St. Louis, Missouri 63110
| | | | | | | | | |
Collapse
|
15
|
Rowbotham BJ, Egerton-Vernon J, Whitaker AN, Elms MJ, Bunce IH. Plasma cross linked fibrin degradation products in pulmonary embolism. Thorax 1990; 45:684-7. [PMID: 2218975 PMCID: PMC462695 DOI: 10.1136/thx.45.9.684] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Plasma concentrations of cross linked fibrin degradation products, a marker of intravascular thrombosis and fibrinolysis, were measured in 495 patients with suspected pulmonary embolism referred for ventilation-perfusion lung scanning to determine whether concentrations are increased in pulmonary embolism and their potential use in diagnosis. Lung scans were described as normal (n = 66) or as showing a low (n = 292), indeterminate (n = 58), or high probability (n = 79) of pulmonary embolism. There was a difference between the mean levels of cross linked fibrin degradation products in each scan category: normal scans, 142 ng/ml; low probability scans, 295 ng/ml; indeterminate probability scans, 510 ng/ml; high probability scans, 952 ng/ml (p less than 0.001). Of the patients with high probability scans, 96% had raised concentrations. Explanations for discrepant low results include incorrect scan diagnosis, delay in blood sampling, and anticoagulation. Of the patients with a low or indeterminate probability of pulmonary embolism, 43% had increased concentrations of cross linked fibrin degradation products that could be attributed in most cases to another illness. Owing to the wide range of values in each lung scan diagnostic category, raised concentrations of these fibrin degradation products cannot be used without reference to the patient's clinical state as a discriminatory test for pulmonary embolism. Further evaluation of the significance of normal concentrations in excluding a diagnosis of pulmonary embolism appears to be warranted.
Collapse
Affiliation(s)
- B J Rowbotham
- University of Queensland, Department of Pathology, Australia
| | | | | | | | | |
Collapse
|
16
|
Mannucci PM. Screening for hemostasis during hemorrhagic emergencies. LA RICERCA IN CLINICA E IN LABORATORIO 1989; 19:339-43. [PMID: 2633302 DOI: 10.1007/bf02871823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
We propose a laboratory screening scheme for the hemostatic system to be adopted during hemorrhagic emergencies in hospital patients bleeding excessively to the extent of requiring massive blood transfusions. The aim of the screening scheme is to establish whether excessive bleeding is due to alterations of the hemostatic system or to other causes. Seven tests were chosen on the basis of their simplicity, rapidity and comprehensiveness in the evaluation of the hemostatic system: the platelet count, the prothrombin and activated partial thromboplastin times, the thrombin and reptilase times and the assays of plasma fibrinogen and fibrin(ogen) degradation products. We then attempted to validate the choice of these tests with 172 emergency cases due to excessive bleeding which led to massive blood replacement. The high frequency of abnormalities of one or more tests found in this series (93%) indicates the excellent diagnostic sensitivity of the screening scheme in detecting hemostatic abnormalities. The screening scheme was also useful in the diagnostic work-up of the bleeding disorders most frequently encountered during hemorrhagic emergencies (disseminated intravascular coagulation, liver disease, unsuspected heparinization and the hemostatic defect associated with massive blood transfusion).
Collapse
Affiliation(s)
- P M Mannucci
- Centro Emofilia e Trombosi Angelo Bianchi Bonomi, Università degli Studi ed Ospedale Maggiore, Milano
| |
Collapse
|
17
|
Affiliation(s)
- R J Porte
- Department of Internal Medicine II, University Hospital Dijkzigt, Rotterdam, The Netherlands
| | | | | |
Collapse
|