1
|
Khaledi N, Khan R, Gräfe JL. Historical Progress of Stereotactic Radiation Surgery. J Med Phys 2023; 48:312-327. [PMID: 38223793 PMCID: PMC10783188 DOI: 10.4103/jmp.jmp_62_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 09/24/2023] [Accepted: 09/27/2023] [Indexed: 01/16/2024] Open
Abstract
Radiosurgery and stereotactic radiotherapy have established themselves as precise and accurate areas of radiation oncology for the treatment of brain and extracranial lesions. Along with the evolution of other methods of radiotherapy, this type of treatment has been associated with significant advances in terms of a variety of modalities and techniques to improve the accuracy and efficacy of treatment. This paper provides a comprehensive overview of the progress in stereotactic radiosurgery (SRS) over several decades, and includes a review of various articles and research papers, commencing with the emergence of stereotactic techniques in radiotherapy. Key clinical aspects of SRS, such as fixation methods, radiobiology considerations, quality assurance practices, and treatment planning strategies, are presented. In addition, the review highlights the technological advancements in treatment modalities, encompassing the transition from cobalt-based systems to linear accelerator-based modalities. By addressing these topics, this study aims to offer insights into the advancements that have shaped the field of SRS, that have ultimately enhanced the accuracy and effectiveness of treatment.
Collapse
Affiliation(s)
- Navid Khaledi
- Department of Medical Physics, Cancer Care Manitoba, Winnipeg, MB, Canada
| | - Rao Khan
- Department of Physics, Toronto Metropolitan University, Toronto, ON, Canada
- Department of Physics and Astronomy and Department of Radiation Oncology, Howard University, Washington, District of Columbia, USA
| | - James L. Gräfe
- Department of Physics, Toronto Metropolitan University, Toronto, ON, Canada
- Cancer Care Program, Dr. H. Bliss Murphy Cancer Center. 300 Prince Philip Drive St. John’s, NL, Canada
| |
Collapse
|
2
|
Abstract
OBJECTIVE To determine the long-term hearing preservation rate for spontaneous vestibular schwannoma treated by primary radiotherapy. DATA SOURCES The MEDLINE/PubMed, Web of Science, Cochrane Reviews, and EMBASE databases were searched using a comprehensive Boolean keyword search developed in conjunction with a scientific librarian. English language papers published from 2000 to 2016 were evaluated. STUDY SELECTION Inclusion criteria: full articles, pretreatment and posttreatment audiograms or audiogram based scoring system, vestibular schwannoma only tumor type, reported time to follow-up, published after 1999, use of either Gamma Knife or linear accelerator radiotherapy. EXCLUSION CRITERIA case report or series with fewer than five cases, inadequate audiometric data, inadequate time to follow-up, neurofibromatosis type 2 exceeding 10% of study population, previous treatment exceeding 10% of study population, repeat datasets, use of proton beam therapy, and non-English language. DATA EXTRACTION Two reviewers independently analyzed papers for inclusion. Class A/B, 1/2 hearing was defined as either pure tone average less than or equal to 50 db with speech discrimination score more than or equal to 50%, American Academy of Otolaryngology-Head & Neck Surgery (AAO-HNS) Hearing Class A or B, or Gardner-Robertson Grade I or II. Aggregate data were used when individual data were not specified. DATA SYNTHESIS Means were compared with student t test. CONCLUSIONS Forty seven articles containing a total of 2,195 patients with preserved Class A/B, 1/2 hearing were identified for analysis. The aggregate crude hearing preservation rate was 58% at an average reporting time of 46.6 months after radiotherapy treatment. Analysis of time-based reporting shows a clear trend of decreased hearing preservation extending to 10-year follow-up. This data encourages a future long-term controlled trial.
Collapse
|
3
|
Kohyama S, Uematsu M, Ishihara S, Shima K, Tamai S, Kusano S. An Experience of Stereotactic Radiation Therapy for Primary Intracranial Choriocarcinoma. TUMORI JOURNAL 2018; 87:162-5. [PMID: 11504371 DOI: 10.1177/030089160108700310] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We report on a patient with choriocarcinoma in the pineal region who was successfully treated with stereotactic radiation therapy (SRT). The increased level of serum human chorionic gonadotropin (HCG) was lowered during chemotherapy with etoposide, cisplatin, and ifosfamide. However, HCG was not normalized and magnetic resonance images still showed an enhanced tumor mass with gadolinium. The patient underwent SRT of 40 Gy at an 80% isodose line per 10 fractions over'two weeks, followed by conventional craniospinal irradiation of 32.4 Gy. The level of HCG dropped below the detection limit. The patient has been in good condition for more than four years after the completion of treatment, without any signs of recurrence. We propose SRT as a valid treatment option for malignant germ cell tumors in the pineal region.
Collapse
Affiliation(s)
- S Kohyama
- Department of Radiology, National Defense Medical College, Tokorozawa, Saitama, Japan.
| | | | | | | | | | | |
Collapse
|
4
|
Keeling V, Hossain S, Jin H, Algan O, Ahmad S, Ali I. Quantitative evaluation of patient setup uncertainty of stereotactic radiotherapy with the frameless 6D ExacTrac system using statistical modeling. J Appl Clin Med Phys 2016; 17:111-127. [PMID: 27167267 PMCID: PMC5690915 DOI: 10.1120/jacmp.v17i3.5959] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2015] [Revised: 01/18/2016] [Accepted: 01/11/2016] [Indexed: 11/23/2022] Open
Abstract
The purpose of this study is to evaluate patient setup accuracy and quantify individual and cumulative positioning uncertainties associated with different hardware and software components of the stereotactic radiotherapy (SRS/SRT) with the frameless 6D ExacTrac system. A statistical model is used to evaluate positioning uncertainties of the different components of SRS/SRT treatment with the Brainlab 6D ExacTrac system using the positioning shifts of 35 patients having cranial lesions. All these patients are immobilized with rigid head‐and‐neck masks, simulated with Brainlab localizer and planned with iPlan treatment planning system. Stereoscopic X‐ray images (XC) are acquired and registered to corresponding digitally reconstructed radiographs using bony‐anatomy matching to calculate 6D translational and rotational shifts. When the shifts are within tolerance (0.7 mm and 1°), treatment is initiated. Otherwise corrections are applied and additional X‐rays (XV) are acquired to verify that patient position is within tolerance. The uncertainties from the mask, localizer, IR ‐frame, X‐ray imaging, MV, and kV isocentricity are quantified individually. Mask uncertainty (translational: lateral, longitudinal, vertical; rotational: pitch, roll, yaw) is the largest and varies with patients in the range (−2.07−3.71mm,−5.82−5.62mm,−5.84−3.61mm;−2.10−2.40∘,−2.23−2.60∘,and−2.7−3.00∘) obtained from mean of XC shifts for each patient. Setup uncertainty in IR positioning (0.88, 2.12, 1.40 mm, and 0.64°, 0.83°, 0.96°) is extracted from standard deviation of XC. Systematic uncertainties of the frame (0.18, 0.25, −1.27mm, −0.32∘, 0.18°, and 0.47°) and localizer (−0.03, −0.01, 0.03 mm, and −0.03∘, 0.00°, −0.01∘) are extracted from means of all XV setups and mean of all XC distributions, respectively. Uncertainties in isocentricity of the MV radiotherapy machine are (0.27, 0.24, 0.34 mm) and kV imager (0.15, −0.4, 0.21 mm). A statistical model is developed to evaluate the individual and cumulative systematic and random positioning uncertainties induced by the different hardware and software components of the 6D ExacTrac system. The uncertainties from the mask, localizer, IR frame, X‐ray imaging, couch, MV linac, and kV imager isocentricity are quantified using statistical modeling. PACS number(s): 87.56.B‐, 87.59.B‐
Collapse
Affiliation(s)
- Vance Keeling
- Stephenson Oklahoma Cancer Center; University of Oklahoma Health Sciences Center.
| | | | | | | | | | | |
Collapse
|
5
|
Li W, Bootsma G, Von Schultz O, Carlsson P, Laperriere N, Millar BA, Jaffray D, Chung C. Preliminary Evaluation of a Novel Thermoplastic Mask System with Intra-fraction Motion Monitoring for Future Use with Image-Guided Gamma Knife. Cureus 2016; 8:e531. [PMID: 27081592 PMCID: PMC4829406 DOI: 10.7759/cureus.531] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Objectives A non-invasive immobilization system consisting of a thermoplastic mask with image-guidance using cone-beam CT (CBCT) and infrared (IR) tracking has been developed to ensure minimal inter- and intra-fractional movement during Gamma Knife radiosurgery. Prior to clinical use for patients on a Gamma Knife, this study clinically evaluates the accuracy and stability of this novel immobilization system with image-guidance in patients treated with standard fractionated radiation therapy on a linear accelerator. Materials & methods This prospective cohort study evaluated adult patients planned for fractionated brain radiotherapy. Patients were immobilized with a thermoplastic mask (with the nose cut out) and customized head cushion. A reflective marker was placed on the patient’s nose tip and tracked with a stereoscopic IR camera throughout treatment. For each fraction, a pre-treatment, verification (after any translational correction for inter-fraction set-up variation), and post-treatment CBCT was acquired to evaluate inter- and intra-fraction movement of the target and nose. Intra-fraction motion of the nose tip measured on CBCT and IR tracking were compared. Results Corresponding data from 123 CBCT and IR datasets from six patients are summarized. The mean ± standard deviation (SD) intra-fraction motion of the nose tip was 0.41±0.36 mm based on pre- and post-treatment CBCT data compared with 0.56±0.51 mm using IR tracking. The maximum intra-fraction motion of the nose tip was 1.7 mm using CBCT and 3.2 mm using IR tracking. The mean ± SD intra-fraction motion of the target was 0.34±0.25 mm, and the maximum intra-fraction motion was 1.5 mm. Conclusions: This initial clinical evaluation of the thermoplastic mask immobilization system using both IR tracking and CBCT demonstrate that mean intra-fraction motion of the nose and target is small. The presence of isolated measures of larger intra-fraction motion supports the need for image-guidance and intra-fraction motion management when using this mask-based immobilization system for radiosurgery.
Collapse
Affiliation(s)
- Winnie Li
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, ON
| | - Gregory Bootsma
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON / University Health Network, Toronto, ON
| | - Oscar Von Schultz
- Elekta Research & Development, Elekta Instruments AB, Stockholm, Sweden
| | - Per Carlsson
- Elekta Research & Development, Elekta Instruments AB, Stockholm, Sweden
| | - Normand Laperriere
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, ON
| | - Barbara-Ann Millar
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, ON
| | - David Jaffray
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, ON
| | - Caroline Chung
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON / University Health Network, Toronto, ON
| |
Collapse
|
6
|
Implementation and validation of a new fixation system for stereotactic radiation therapy: An analysis of patient immobilization. Pract Radiat Oncol 2015. [DOI: 10.1016/j.prro.2015.03.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
7
|
Wissel T, Bruder R, Schweikard A, Ernst F. Estimating soft tissue thickness from light-tissue interactions--a simulation study. BIOMEDICAL OPTICS EXPRESS 2013; 4:1176-1187. [PMID: 23847741 PMCID: PMC3704097 DOI: 10.1364/boe.4.001176] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2013] [Accepted: 06/09/2013] [Indexed: 06/02/2023]
Abstract
Immobilization and marker-based motion tracking in radiation therapy often cause decreased patient comfort. However, the more comfortable alternative of optical surface tracking is highly inaccurate due to missing point-to-point correspondences between subsequent point clouds as well as elastic deformation of soft tissue. In this study, we present a proof of concept for measuring subcutaneous features with a laser scanner setup focusing on the skin thickness as additional input for high accuracy optical surface tracking. Using Monte-Carlo simulations for multi-layered tissue, we show that informative features can be extracted from the simulated tissue reflection by integrating intensities within concentric ROIs around the laser spot center. Training a regression model with a simulated data set identifies patterns that allow for predicting skin thickness with a root mean square error of down to 18 µm. Different approaches to compensate for varying observation angles were shown to yield errors still below 90 µm. Finally, this initial study provides a very promising proof of concept and encourages research towards a practical prototype.
Collapse
Affiliation(s)
- Tobias Wissel
- Institute for Robotics and Cognitive Systems, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany
- Graduate School for Computing in Medicine and Life Sciences, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany
| | - Ralf Bruder
- Institute for Robotics and Cognitive Systems, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany
| | - Achim Schweikard
- Institute for Robotics and Cognitive Systems, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany
| | - Floris Ernst
- Institute for Robotics and Cognitive Systems, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany
| |
Collapse
|
8
|
Ajeawung NF, Wang HY, Kamnasaran D. Progress from clinical trials and emerging non-conventional therapies for the treatment of Medulloblastomas. Cancer Lett 2012; 330:130-40. [PMID: 23211539 DOI: 10.1016/j.canlet.2012.11.039] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2012] [Revised: 11/19/2012] [Accepted: 11/22/2012] [Indexed: 12/18/2022]
Abstract
Medulloblastomas are highly aggressive tumors of the cerebellum with an embryonal origin. Despite current treatment modalities which include a combination of surgery, chemotherapy and/or radiation, challenges still exist to effectively treat some patients, especially those within the younger age group. In an effort to find improved therapies, ongoing research led by world-wide teams have explored non-conventional therapeutic strategies, as well as examined the efficacy of several drugs in clinical trials among patients with Medulloblastomas. We outline in this article, recent advances on the efficacy and toxicity of numerous therapeutic agents including those that are DNA damaging agents, microtubules binding compounds, and those that are inhibitors of Topoisomerase and of the Notch and Hedgehog signaling pathway, which were assessed in recent Phase I and II clinical trials. Among these clinical trials, it is unfortunate that the outcomes were dismal with the majority of the patients with Medulloblastomas still succumbing to relapse after conventional therapies. Furthermore, it is yet to be established clearly the clinical efficacy of non-conventional therapies such as immunotherapy and gene therapy. Moreover, there is growing interest in proton therapy as a potential replacement for photon therapy, while high dose chemotherapy and autologous stem cell rescue may improve therapeutic efficacies. However, further research is needed to resolve the inherent toxicity from these novel therapeutic methods. In conclusion, novel therapies based on a better understanding of the biology of Medulloblastomas are pivotal in improving non-conventional therapies in the treatment of this deadly disease.
Collapse
|
9
|
Rosenfelder NA, Corsini L, McNair H, Pennert K, Burke K, Lamb CM, Aitken A, Ashley S, Khoo V, Brada M. Achieving the relocation accuracy of stereotactic frame-based cranial radiotherapy in a three-point thermoplastic shell. Clin Oncol (R Coll Radiol) 2012; 25:66-73. [PMID: 22795232 DOI: 10.1016/j.clon.2012.06.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2012] [Revised: 03/25/2012] [Accepted: 06/26/2012] [Indexed: 12/25/2022]
Abstract
AIMS To compare the accuracy of fractionated cranial radiotherapy in a standard three-point thermoplastic shell using daily online correction with accuracy in a Gill-Thomas-Cosman relocatable stereotactic frame. MATERIALS AND METHODS All patients undergoing fractionated radiotherapy for benign intracranial tumours between March 2009 and August 2010 were included. Patients were immobilised in the frame with those unable to tolerate it immobilised in the shell. The ExacTrac imaging system was used for verification/correction. Daily online imaging before and after correction was carried out for shell patients and systematic and random population set-up errors calculated. These were compared with frame patients who underwent standard departmental imaging/correction with fractions 1-3 and weekly thereafter. Set-up margins were calculated from population errors. RESULTS Systematic and random errors were 0.3-0.7 mm/° before correction and 0.1-0.2 mm/° after correction in all axes in the frame, and 0.6-1.5 mm/° before correction and 0.1-0.4 mm/° after correction in the shell. Isotropic margins required for patient set-up could be reduced from 2 mm to <1 mm in the frame and from 5 mm to <1 mm in the shell. CONCLUSION Similar set-up accuracy can be achieved in the standard thermoplastic shell as in a relocatable frame despite less precise immobilisation. The use of daily online correction precludes the need for larger set-up margins.
Collapse
Affiliation(s)
- N A Rosenfelder
- Department of Clinical Oncology, Royal Marsden NHS Foundation Trust, London, UK.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Winey B, Daartz J, Dankers F, Bussière M. Immobilization precision of a modified GTC frame. J Appl Clin Med Phys 2012; 13:3690. [PMID: 22584167 PMCID: PMC5716563 DOI: 10.1120/jacmp.v13i3.3690] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2011] [Revised: 12/19/2011] [Accepted: 12/22/2011] [Indexed: 11/23/2022] Open
Abstract
The purpose of this study was to evaluate and quantify the interfraction reproducibility and intrafraction immobilization precision of a modified GTC frame. The error of the patient alignment and imaging systems were measured using a cranial skull phantom, with simulated, predetermined shifts. The kV setup images were acquired with a room‐mounted set of kV sources and panels. Calculated translations and rotations provided by the computer alignment software relying upon three implanted fiducials were compared to the known shifts, and the accuracy of the imaging and positioning systems was calculated. Orthogonal kV setup images for 45 proton SRT patients and 1002 fractions (average 22.3 fractions/patient) were analyzed for interfraction and intrafraction immobilization precision using a modified GTC frame. The modified frame employs a radiotransparent carbon cup and molded pillow to allow for more treatment angles from posterior directions for cranial lesions. Patients and the phantom were aligned with three 1.5 mm stainless steel fiducials implanted into the skull. The accuracy and variance of the patient positioning and imaging systems were measured to be 0.10±0.06 mm, with the maximum uncertainty of rotation being ±0.07°.957 pairs of interfraction image sets and 974 intrafraction image sets were analyzed. 3D translations and rotations were recorded. The 3D vector interfraction setup reproducibility was 0.13 mm ±1.8 mm for translations and the largest uncertainty of ±1.07° for rotations. The intrafraction immobilization efficacy was 0.19 mm ±0.66 mm for translations and the largest uncertainty of ±0.50° for rotations. The modified GTC frame provides reproducible setup and effective intrafraction immobilization, while allowing for the complete range of entrance angles from the posterior direction. PACS number: 87.53.Ly, 87.55.Qr
Collapse
Affiliation(s)
- Brian Winey
- Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| | | | | | | |
Collapse
|
11
|
Abstract
The increasing efficacy of pediatric cancer therapy over the past four decades has produced many long-term survivors that now struggle with serious treatment related morbidities affecting their quality of life. Radiation therapy is responsible for a significant proportion of these late effects, but a relatively new and emerging modality, proton radiotherapy hold great promise to drastically reduce these treatment related late effects in long term survivors by sparing dose to normal tissues. Dosimetric studies of proton radiotherapy compared with best available photon based treatment show significant dose sparing to developing normal tissues. Furthermore, clinical data are now emerging that begin to quantify the benefit in decreased late treatment effects while maintaining excellent cancer control rates.
Collapse
Affiliation(s)
- Shane E Cotter
- Department of Radiation Oncology, Brigham and Women's Hospital and Dana Farber Cancer Institute, Boston, MA 02115, USA
| | | | | |
Collapse
|
12
|
Muller K, Naus N, Nowak PJ, Schmitz PI, de Pan C, van Santen CA, Marijnissen JP, Paridaens DA, Levendag PC, Luyten GP. Fractionated stereotactic radiotherapy for uveal melanoma, late clinical results. Radiother Oncol 2012; 102:219-24. [DOI: 10.1016/j.radonc.2011.06.038] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2010] [Revised: 04/16/2011] [Accepted: 06/24/2011] [Indexed: 12/17/2022]
|
13
|
Theelen A, Martens J, Bosmans G, Houben R, Jager JJ, Rutten I, Lambin P, Minken AW, Baumert BG. Relocatable fixation systems in intracranial stereotactic radiotherapy. Accuracy of serial CT scans and patient acceptance in a randomized design. Strahlenther Onkol 2011; 188:84-90. [PMID: 22194025 DOI: 10.1007/s00066-011-0018-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2011] [Accepted: 06/28/2011] [Indexed: 12/25/2022]
Abstract
PURPOSE The goal was to provide a quantitative evaluation of the accuracy of three different fixation systems for stereotactic radiotherapy and to evaluate patients' acceptance for all fixations. METHODS A total of 16 consecutive patients with brain tumours undergoing fractionated stereotactic radiotherapy (SCRT) were enrolled after informed consent (Clinical trials.gov: NCT00181350). Fixation systems evaluated were the BrainLAB® mask, with and without custom made bite-block (fixations S and A) and a homemade neck support with bite-block (fixation B) based on the BrainLAB® frame. The sequence of measurements was evaluated in a randomized manner with a cross-over design and patients' acceptance by a questionnaire. RESULTS The mean three-dimensional (3D) displacement and standard deviations were 1.16 ± 0.68 mm for fixation S, 1.92 ± 1.28 and 1.70 ± 0.83 mm for fixations A and B, respectively. There was a significant improvement of the overall alignment (3D vector) when using the standard fixation instead of fixation A or B in the craniocaudal direction (p = 0.037). Rotational deviations were significantly less for the standard fixation S in relation to fixations A (p = 0.005) and B (p = 0.03). EPI imaging with off-line correction further improved reproducibility. Five out of 8 patients preferred the neck support with the bite-block. CONCLUSION The mask fixation system in conjunction with a bite-block is the most accurate fixation for SCRT reducing craniocaudal and rotational movements. Patients favoured the more comfortable but less accurate neck support. To optimize the accuracy of SCRT, additional regular portal imaging is warranted.
Collapse
Affiliation(s)
- A Theelen
- Department of Radiation-Oncology (MAASTRO), GROW (School for Oncology & Developmental Biology), Maastricht University Medical Centre, Dr Tanslaan 12, 6229, Maastricht, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Minniti G, Scaringi C, Clarke E, Valeriani M, Osti M, Enrici RM. Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomes. Radiat Oncol 2011; 6:158. [PMID: 22085700 PMCID: PMC3253058 DOI: 10.1186/1748-717x-6-158] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2011] [Accepted: 11/16/2011] [Indexed: 11/21/2022] Open
Abstract
Purpose To assess the accuracy of patient repositioning and clinical outcomes of frameless stereotactic radiosurgery (SRS) for brain metastases using a stereotactic mask fixation system. Patients and Methods One hundred two patients treated consecutively with frameless SRS as primary treatment at University of Rome Sapienza Sant'Andrea Hospital between October 2008 and April 2010 and followed prospectively were involved in the study. A commercial stereotactic mask fixation system (BrainLab) was used for patient immobilization. A computerized tomography (CT) scan obtained immediately before SRS was used to evaluate the accuracy of patient repositioning in the mask by comparing the isocenter position to the isocenter position established in the planning CT. Deviations of isocenter coordinates in each direction and 3D displacement were calculated. Overall survival, brain control, and local control were estimated using the Kaplan-Meier method calculated from the time of SRS. Results The mean measured isocenter displacements were 0.12 mm (SD 0.35 mm) in the lateral direction, 0.2 mm (SD 0.4 mm) in the anteroposterior, and 0.4 mm (SD 0.6 mm) in craniocaudal direction. The maximum displacement of 2.1 mm was seen in craniocaudal direction. The mean 3D displacement was 0.5 mm (SD 0.7 mm), being maximum 2.9 mm. The median survival was 15.5 months, and 1-year and 2-year survival rates were 58% and 24%, respectively. Nine patients recurred locally after SRS, with 1-year and 2-year local control rates of 91% and 82%, respectively. Stable extracranial disease (P = 0.001) and KPS > 70 (P = 0.01) were independent predictors of survival. Conclusions Frameless SRS is an effective treatment in the management of patients with brain metastases. The presented non-invasive mask-based fixation stereotactic system is associated with a high degree of patient repositioning accuracy; however, a careful evaluation is essential since occasional errors up to 3 mm may occur.
Collapse
Affiliation(s)
- Giuseppe Minniti
- Department of Radiation Oncology, Sant' Andrea Hospital, University Sapienza, Rome, Italy.
| | | | | | | | | | | |
Collapse
|
15
|
Gladstone DJ, Li S, Jarvis LA, Hartford AC. Case report of a near medical event in stereotactic radiotherapy due to improper units of measure from a treatment planning system. Med Phys 2011; 38:4108-11. [PMID: 21859011 DOI: 10.1118/1.3598444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The authors hereby notify the Radiation Oncology community of a potentially lethal error due to improper implementation of linear units of measure in a treatment planning system. The authors report an incident in which a patient was nearly mistreated during a stereotactic radiotherapy procedure due to inappropriate reporting of stereotactic coordinates by the radiation therapy treatment planning system in units of centimeter rather than in millimeter. The authors suggest a method to detect such errors during treatment planning so they are caught and corrected prior to the patient positioning for treatment on the treatment machine. METHODS Using pretreatment imaging, the authors found that stereotactic coordinates are reported with improper linear units by a treatment planning system. The authors have implemented a redundant, independent method of stereotactic coordinate calculation. RESULTS Implementation of a double check of stereotactic coordinates via redundant, independent calculation is simple and accurate. Use of this technique will avoid any future error in stereotactic treatment coordinates due to improper linear units, transcription, or other similar errors. CONCLUSIONS The authors recommend an independent double check of stereotactic treatment coordinates during the treatment planning process in order to avoid potential mistreatment of patients.
Collapse
Affiliation(s)
- D J Gladstone
- Division of Radiation Oncology, Department of Medicine, Dartmouth-Hitchcock Medical Center, Norris Cotton Cancer Center, Lebanon, New Hampshire 03756, USA.
| | | | | | | |
Collapse
|
16
|
Ackerly T, Lancaster CM, Geso M, Roxby KJ. Clinical accuracy of ExacTrac intracranial frameless stereotactic system. Med Phys 2011; 38:5040-8. [PMID: 21978048 DOI: 10.1118/1.3611044] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Affiliation(s)
- T Ackerly
- William Buckland Radiotherapy Centre, Alfred Hospital, Melbourne 3004, Australia.
| | | | | | | |
Collapse
|
17
|
Li S, Kleinberg LR, Rigamonti D, Wharam MD, Rashid A, Jackson J, Djajaputra D, He S, Creasey T, DeWeese TL. Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy. Technol Cancer Res Treat 2011; 9:603-17. [PMID: 21070083 DOI: 10.1177/153303461000900609] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Real-time stereovision-guidance has been introduced for efficient and convenient fractionated stereotactic radiotherapy (FSR) and image-guided intensity-modulated radiation therapy (IMRT). This first pilot study is to clinically evaluate its accuracy and precision as well as impact on treatment doses. Sixty-one FSR patients wearing stereotactic masks (SMs) and nine IMRT patients wearing flexible masks (FMs), were accrued. Daily target reposition was initially based-on biplane-radiographs and then adjusted in six degrees of freedom under real-time stereovision guidance. Mean and standard deviation of the head displacements measured the accuracy and precision. Head positions during beam-on times were measured with real-time stereovisions and used for determination of delivered doses. Accuracy ± ± precision in direction with the largest errors shows improvement from 0.4 ± 2.3 mm to 0.0 ± 1.0 mm in the inferior-to-superior direction for patients wearing SM or from 0.8 ± 4.3 mm to 0.4 ± 1.7 mm in the posterior-to-anterior direction for patients wearing FM. The image-guidance increases target volume coverage by >30% for small lesions. Over half of head position errors could be removed from the stereovision-guidance. Importantly, the technique allows us to check head position during beam-on time and makes it possible for having frameless head refixation without tight masks.
Collapse
Affiliation(s)
- Shidong Li
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Wilbert J, Guckenberger M, Polat B, Sauer O, Vogele M, Flentje M, Sweeney RA. Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results. Radiat Oncol 2010; 5:42. [PMID: 20504338 PMCID: PMC2890022 DOI: 10.1186/1748-717x-5-42] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2010] [Accepted: 05/26/2010] [Indexed: 11/28/2022] Open
Abstract
Background To introduce a novel method of patient positioning for high precision intracranial radiotherapy. Methods An infrared(IR)-array, reproducibly attached to the patient via a vacuum-mouthpiece(vMP) and connected to the table via a 6 degree-of-freedom(DoF) mechanical arm serves as positioning and fixation system. After IR-based manual prepositioning to rough treatment position and fixation of the mechanical arm, a cone-beam CT(CBCT) is performed. A robotic 6 DoF treatment couch (HexaPOD™) then automatically corrects all remaining translations and rotations. This absolute position of infrared markers at the first fraction acts as reference for the following fractions where patients are manually prepositioned to within ± 2 mm and ± 2° of this IR reference position prior to final HexaPOD-based correction; consequently CBCT imaging is only required once at the first treatment fraction. The preclinical feasibility and attainable repositioning accuracy of this method was evaluated on a phantom and human volunteers as was the clinical efficacy on 7 pilot study patients. Results Phantom and volunteer manual IR-based prepositioning to within ± 2 mm and ± 2° in 6DoF was possible within a mean(± SD) of 90 ± 31 and 56 ± 22 seconds respectively. Mean phantom translational and rotational precision after 6 DoF corrections by the HexaPOD was 0.2 ± 0.2 mm and 0.7 ± 0.8° respectively. For the actual patient collective, the mean 3D vector for inter-treatment repositioning accuracy (n = 102) was 1.6 ± 0.8 mm while intra-fraction movement (n = 110) was 0.6 ± 0.4 mm. Conclusions This novel semi-automatic 6DoF IR-based system has been shown to compare favourably with existing non-invasive intracranial repeat fixation systems with respect to handling, reproducibility and, more importantly, intra-fraction rigidity. Some advantages are full cranial positioning flexibility for single and fractionated IGRT treatments and possibly increased patient comfort.
Collapse
Affiliation(s)
- Jürgen Wilbert
- Department of Radiation Oncology, University Hospital Würzburg, Josef-Schneider-Str. 11, 97080 Würzburg, Germany
| | | | | | | | | | | | | |
Collapse
|
19
|
Ali I, Tubbs J, Hibbitts K, Algan O, Thompson S, Herman T, Ahmad S. Evaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on-board imaging. J Appl Clin Med Phys 2010; 11:3192. [PMID: 20717086 PMCID: PMC5720447 DOI: 10.1120/jacmp.v11i3.3192] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2009] [Revised: 12/01/2009] [Accepted: 03/27/2010] [Indexed: 11/24/2022] Open
Abstract
The purpose of this study was to evaluate setup accuracy and quantify random and systematic errors of the BrainLAB stereotactic immobilization mask and localization system using kV on‐board imaging. Nine patients were simulated and set up with the BrainLAB stereotactic head immobilization mask and localizer to be treated for brain lesions using single and hypofractions. Orthogonal pairs of projections were acquired using a kV on‐board imager mounted on a Varian Trilogy machine. The kV projections were then registered with digitally‐reconstructed radiographs (DRR) obtained from treatment planning. Shifts between the kV images and reference DRRs were calculated in the different directions: anterior‐posterior (A‐P), medial‐lateral (R‐L) and superior‐inferior (S‐I). If the shifts were larger than 2 mm in any direction, the patient was reset within the immobilization mask until satisfying setup accuracy based on image guidance has been achieved. Shifts as large as 4.5 mm, 5.0 mm, 8.0 mm in the A‐P, R‐L and S‐I directions, respectively, were measured from image registration of kV projections and DRRs. These shifts represent offsets between the treatment and simulation setup using immobilization mask. The mean offsets of 0.1 mm, 0.7 mm, and −1.6 mm represent systematic errors of the BrainLAB localizer in the A‐P, R‐L and S‐I directions, respectively. The mean of the radial shifts is about 1.7 mm. The standard deviations of the shifts were 2.2 mm, 2.0 mm, and 2.6 mm in A‐P, R‐L and S‐I directions, respectively, which represent random patient setup errors with the BrainLAB mask. The BrainLAB mask provides a noninvasive, practical and flexible immobilization system that keeps the patients in place during treatment. Relying on this system for patient setup might be associated with significant setup errors. Image guidance with the kV on‐board imager provides an independent verification technique to ensure accuracy of patient setup. Since the patient may relax or move during treatment, uncontrolled and undetected setup errors may be produced with patients that are not well‐immobilized. Therefore, the combination of stereotactic immobilization and image guidance achieves more controlled and accurate patient setup within 2 mm in A‐P, R‐L and S‐I directions. PACS numbers: 87.56.‐v, 87.56.Da
Collapse
Affiliation(s)
- Imad Ali
- Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA.
| | | | | | | | | | | | | |
Collapse
|
20
|
Sanghera P, Lightstone AW, Hyde DE, Davey P. Case report. Fractionated Helical Tomotherapy as an alternative to radiosurgery in patients unwilling to undergo additional radiosurgery for recurrent brain metastases. Br J Radiol 2010; 83:e25-30. [PMID: 20139253 DOI: 10.1259/bjr/19238690] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Our clinic routinely treats brain metastases with stereotactic radiosurgery using a 6 megavoltage (MV) linear accelerator, cones, and a surgically attached head frame. Four patients declined repeat radiosurgery for new lesions due to their previous discomfort and a fifth patient could not complete radiosurgery because of uncontrolled nausea. Instead patients were treated with Helical Tomotherapy (HT). This report discusses the spatial dose distribution of HT as measured in a head phantom and the clinical course of these five patients. The planning target volume (PTV) was a 3 mm geometric expansion of the gross tumour volume (GTV). The prescribed dose to the PTV was 27 Gy in five daily fractions with the distribution optimised to deliver 30 Gy to the GTV. Patients were immobilised with a mask and the lesions were targeted by MV computerised tomography, an inherent feature of the system. One patient died six weeks later from systemic disease; the remaining patients survived eight to 16 months. No patient experienced an exacerbation of neurological symptoms following Helical Tomotherapy. These results suggest that fractionated Helical Tomotherapy for brain metastases may be a viable alternative to radiosurgery in patients unable or unwilling to undergo that procedure.
Collapse
Affiliation(s)
- P Sanghera
- Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
| | | | | | | |
Collapse
|
21
|
Ramakrishna N, Rosca F, Friesen S, Tezcanli E, Zygmanszki P, Hacker F. A clinical comparison of patient setup and intra-fraction motion using frame-based radiosurgery versus a frameless image-guided radiosurgery system for intracranial lesions. Radiother Oncol 2010; 95:109-15. [PMID: 20116123 DOI: 10.1016/j.radonc.2009.12.030] [Citation(s) in RCA: 110] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2009] [Revised: 12/08/2009] [Accepted: 12/29/2009] [Indexed: 10/19/2022]
Abstract
BACKGROUND AND PURPOSE A comparison of patient positioning and intra-fraction motion using invasive frame-based radiosurgery with a frameless X-ray image-guided system utilizing a thermoplastic mask for immobilization. MATERIALS AND METHODS Overall system accuracy was determined using 57 hidden-target tests. Positioning agreement between invasive frame-based setup and image-guided (IG) setup, and intra-fraction displacement, was evaluated for 102 frame-based SRS treatments. Pre and post-treatment imaging was also acquired for 7 patients (110 treatments) immobilized with an aquaplast mask receiving fractionated IG treatment. RESULTS The hidden-target tests demonstrated a mean error magnitude of 0.7mm (SD=0.3mm). For SRS treatments, mean deviation between frame-based and image-guided initial positioning was 1.0mm (SD=0.5mm). Fusion failures were observed among 3 patients resulting in aberrant predicted shifts. The image-guidance system detected frame slippage in one case. The mean intra-fraction shift magnitude observed for the BRW frame was 0.4mm (SD=0.3mm) compared to 0.7mm (SD=0.5mm) for the fractionated patients with the mask system. CONCLUSIONS The overall system accuracy is similar to that reported for invasive frame-based SRS. The intra-fraction motion was larger with mask-immobilization, but remains within a range appropriate for stereotactic treatment. These results support clinical implementation of frameless radiosurgery using the Novalis Body Exac-Trac system.
Collapse
Affiliation(s)
- Naren Ramakrishna
- Department of Radiation Oncology, Brigham and Women's Hospital and Dana Farber Cancer Institute, Boston, MA, USA.
| | | | | | | | | | | |
Collapse
|
22
|
Minniti G, Valeriani M, Clarke E, D'Arienzo M, Ciotti M, Montagnoli R, Saporetti F, Enrici RM. Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation system. Radiat Oncol 2010; 5:1. [PMID: 20070901 PMCID: PMC2823752 DOI: 10.1186/1748-717x-5-1] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2009] [Accepted: 01/13/2010] [Indexed: 11/20/2022] Open
Abstract
Background To assess the accuracy of fractionated stereotactic radiotherapy (FSRT) using a stereotactic mask fixation system. Patients and Methods Sixteen patients treated with FSRT were involved in the study. A commercial stereotactic mask fixation system (BrainLAB AG) was used for patient immobilization. Serial CT scans obtained before and during FSRT were used to assess the accuracy of patient immobilization by comparing the isocenter position. Daily portal imaging were acquired to establish day to day patient position variation. Displacement errors along the different directions were calculated as combination of systematic and random errors. Results The mean isocenter displacements based on localization and verification CT imaging were 0.1 mm (SD 0.3 mm) in the lateral direction, 0.1 mm (SD 0.4 mm) in the anteroposterior, and 0.3 mm (SD 0.4 mm) in craniocaudal direction. The mean 3D displacement was 0.5 mm (SD 0.4 mm), being maximum 1.4 mm. No significant differences were found during the treatment (P = 0.4). The overall isocenter displacement as calculated by 456 anterior and lateral portal images were 0.3 mm (SD 0.9 mm) in the mediolateral direction, -0.2 mm (SD 1 mm) in the anteroposterior direction, and 0.2 mm (SD 1.1 mm) in the craniocaudal direction. The largest displacement of 2.7 mm was seen in the cranio-caudal direction, with 95% of displacements < 2 mm in any direction. Conclusions The results indicate that the setup error of the presented mask system evaluated by CT verification scans and portal imaging are minimal. Reproducibility of the isocenter position is in the best range of positioning reproducibility reported for other stereotactic systems.
Collapse
Affiliation(s)
- Giuseppe Minniti
- Department of Radiation Oncology, Sant' Andrea Hospital, University La Sapienza, via di Grottarossa 1035-1039, 00189, Rome, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Takakura T, Mizowaki T, Nakata M, Yano S, Fujimoto T, Miyabe Y, Nakamura M, Hiraoka M. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system. Phys Med Biol 2009; 55:1-10. [DOI: 10.1088/0031-9155/55/1/001] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
|
25
|
Effect of MLC Leaf Width and PTV Margin on the Treatment Planning of Intensity-Modulated Stereotactic Radiosurgery (IMSRS) or Radiotherapy (IMSRT). Med Dosim 2009; 34:110-6. [DOI: 10.1016/j.meddos.2008.06.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2008] [Revised: 05/14/2008] [Accepted: 06/03/2008] [Indexed: 11/17/2022]
|
26
|
Bednarz G, Machtay M, Werner-Wasik M, Downes B, Bogner J, Hyslop T, Galvin J, Evans J, Curran W, Andrews D. Report on a randomized trial comparing two forms of immobilization of the head for fractionated stereotactic radiotherapy. Med Phys 2009; 36:12-7. [PMID: 19235368 DOI: 10.1118/1.3030950] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Fractionated stereotactic radiotherapy (SRT) requires accurate and reproducible immobilization of the patient's head. This randomized study compared the efficacy of two commonly used forms of immobilization used for SRT. Two routinely used methods of immobilization, which differ in their approach to reproduce the head position from day to day, are the Gill-Thomas-Cosman (GTC) frame and the BrainLab thermoplastic mask. The GTC frame fixates on the patient's upper dentition and thus is in direct mechanical contact with the cranium. The BrainLab mask is a two-part masking system custom fitted to the front and back of the patient's head. After patients signed an IRB-approved informed consent form, eligible patients were randomized to either GTC frame or mask for their course of SRT. Patients were treated as per standard procedure; however, prior to each treatment a set of digital kilovolt images (ExacTrac, BrainLabAB, Germany) was taken. These images were fused with reference digitally reconstructed radiographs obtained from treatment planning CT to yield lateral, longitudinal, and vertical deviations of isocenter and head rotations about respective axes. The primary end point of the study was to compare the two systems with respect to mean and standard deviations using the distance to isocenter measure. A total of 84 patients were enrolled (69 patients evaluable with detailed positioning data). A mixed-effect linear regression and two-tiled t test were used to compare the distance measure for both the systems. There was a statistically significant (p < 0.001) difference between mean distances for these systems, suggesting that the GTC frame was more accurate. The mean 3D displacement and standard deviations were 3.17+1.95 mm for mask and 2.00+1.04 mm for frame. Both immobilization techniques were highly effective, but the GTC frame was more accurate. To optimize the accuracy of SRT, daily kilovolt image guidance is recommended with either immobilization system.
Collapse
Affiliation(s)
- Greg Bednarz
- Department of Radiation Oncology, Kimmel Cancer Center, Jefferson Medical College, Philadelphia, Pennsylvania 19107, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Abstract
The multimodality management of visual pathway tumors frequently involves radiation. Most commonly, photons are delivered via multiple focused beams aimed at the tumor while sparing adjacent tissues. The dose can be delivered in multiple treatments (radiation therapy) or in a single treatment (radiosurgery). Children with visual pathway gliomas should be treated with chemotherapy alone, delaying the use of radiation therapy until progression. Definitive radiation therapy of optic nerve sheath meningiomas results in stable vision in most patients. Radiation therapy or radiosurgery for pituitary tumors can result in control of both tumor growth and hormone hypersecretion. Postoperative radiation therapy or radiosurgery of craniopharyngiomas significantly improves local control rates compared with surgery alone. Radiation therapy is highly effective for eradicating orbital pseudolymphoma and lymphoma. The risk of complications from radiation treatment is dependent on the organ at risk, the cumulative dose it receives, and the dose delivered per fraction.
Collapse
|
28
|
Girvigian MR, Chen JCT, Rahimian J, Miller MJ, Tome M. Comparison of early complications for patients with convexity and parasagittal meningiomas treated with either stereotactic radiosurgery or fractionated stereotactic radiotherapy. Neurosurgery 2008; 62:A19-27; discussion A27-8. [PMID: 18580776 DOI: 10.1227/01.neu.0000325933.34154.cb] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Patients with convexity and parasagittal (CPS) meningiomas treated with stereotactic radiosurgery (SRS) have been shown to be at risk for posttreatment symptomatic peritumoral edema (SPTE). We sought to analyze the pattern of this complication and compare it with the SPTE experienced in our patients treated with fractionated stereotactic radiotherapy. METHODS From January 2003 to October 2005, 32 patients with CPS meningiomas were treated. Thirty patients with a total of 38 lesions had sufficient follow-up for analysis. Group A (n = 14) patients were treated with single fraction SRS, and Group B (n = 16) patients were treated with fractionated stereotactic radiotherapy. The lesion volume was different between the two groups with the Group B median volume (7.46 cm) being larger than that for Group A (2.84 cm) (P = 0.0008). Conversely age, follow-up, sex, prior surgical events, number of lesions, tumor location, and atypical histology did not differ between these groups. The median marginal dose for patients in Group A was 14 Gy (range, 12.5-18 Gy). For Group B, six patients received a median marginal dose of 50.4 Gy in 28 fractions, and 10 patients received a marginal dose of 25 Gy in five fractions. RESULTS Seven of the 30 patients treated in this series developed posttreatment SPTE. The incidence of SPTE in Group A (six of 14 patients) was significantly higher than that in Group B (one of 16 patients) (P = 0.031). The median time to onset of SPTE in the six patients in Group A was 4 months. In Group B, one patient had onset of SPTE in 3 months. On univariate analysis, larger tumor volume (P = 0.0014) and tumor margin dose >14 Gy in patients undergoing SRS (P = 0.031) was associated with onset of SPTE. Age, previous surgery, and tumor location were not associated with onset of SPTE. CONCLUSION Despite larger lesion volumes, fractionated stereotactic radiotherapy is associated with less risk of posttreatment SPTE than SRS for patients with CPS meningiomas in our series. For patients treated with SRS, smaller volume and dose <14 Gy seems to be safe. Longer follow-up will be required to compare late complications and tumor control rates in these patients.
Collapse
Affiliation(s)
- Michael R Girvigian
- Department of Radiation Oncology, Kaiser Permanente Los Angeles Medical Center and the Southern California Permanente Medical Group, Los Angeles, California, USA.
| | | | | | | | | |
Collapse
|
29
|
Benedict SH, Bova FJ, Clark B, Goetsch SJ, Hinson WH, Leavitt DD, Schlesinger DJ, Yenice KM. The role of medical physicists in developing stereotactic radiosurgery. Med Phys 2008; 35:4262-77. [DOI: 10.1118/1.2969268] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
|
30
|
Munier FL, Verwey J, Pica A, Balmer A, Zografos L, Abouzeid H, Timmerman B, Goitein G, Moeckli R. New developments in external beam radiotherapy for retinoblastoma: from lens to normal tissue-sparing techniques. Clin Exp Ophthalmol 2008; 36:78-89. [PMID: 18290958 DOI: 10.1111/j.1442-9071.2007.01602.x] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Historically, retinoblastoma was treated with external beam radiotherapy (EBR) and for many years this was the accepted standard of care. With greater knowledge of radiation-induced morbidity and mortality, the trend over the past decade has shifted towards primary chemotherapy for most globe conservative treatments. Such a radical change in treatment modalities has restrained EBR to second-line and salvage indications with little consensus regarding dose, timing and techniques. New radiotherapy options now allow for more focused radiation to the globe with further sparing of adjacent structures in such a way that their role in the management of retinoblastoma need to be reappraised. In this perspective paper, first the historical techniques of using EBR primarily with linear accelerated photons are reviewed. Then modern approaches are described, such as stereotactic conformal radiotherapy using a micromultileaf collimator, and proton therapy using a fixed horizontal beam and tantalum localization, or a rotating ganthry with spot scanning. For the first time, to the authors' knowledge, the benefits of these new irradiation modalities over conventional EBR are illustrated with six successfully treated pilot cases. Finally, some guidelines are provided regarding indications to modern radiation therapy in patients requiring second-line or salvage treatment for intraocular retinoblastoma, as well as adjuvant therapy for orbital involvement.
Collapse
|
31
|
Ramos-Cruz MV, Bohle GC. A technique for fabricating the dental positioning component for stereotactic radiotherapy. J Prosthet Dent 2008; 99:160-1. [PMID: 18262018 DOI: 10.1016/s0022-3913(08)60033-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Affiliation(s)
- Maria V Ramos-Cruz
- Dental Service, Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY 10021, USA
| | | |
Collapse
|
32
|
|
33
|
Elia AEH, Shih HA, Loeffler JS. Stereotactic radiation treatment for benign meningiomas. Neurosurg Focus 2007; 23:E5. [PMID: 17961042 DOI: 10.3171/foc-07/10/e5] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Meningiomas are the second most common primary tumor of the brain. Gross-total resection remains the preferred treatment if achievable with minimal morbidity. For incompletely resected or inoperable benign meningiomas, 3D conformal external-beam radiation therapy can provide durable local tumor control in 90 to 95% of cases. Stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) are highly conformal techniques, using steep dose gradients and stereotactic patient immobilization. Stereotactic radiosurgery has been used as an alternative or adjuvant therapy to surgery for meningiomas in locations, such as the skull base, where operative manipulation may be particularly difficult. Stereotactic radiotherapy is useful for larger meningiomas (> 3-3.5 cm) and those closely approximating critical structures, such as the optic chiasm and brainstem. Although SRS has longer follow-up than SRT, both techniques have excellent 5-year tumor control rates of greater than 90% for benign meningiomas. Stereotactic radiotherapy has toxicity equivalent to that of radiosurgery, despite its biased use for larger meningiomas with more complicated volumes. Reported rates of imaging-documented regression are higher for radiosurgery, but neurological recovery is relatively good with both techniques. Stereotactic radiosurgery and fractionated SRT are complementary techniques appropriate for different clinical scenarios.
Collapse
Affiliation(s)
- Andrew E H Elia
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | | | | |
Collapse
|
34
|
Feuvret L, Noel G, Weber DC, Pommier P, Ferrand R, De Marzi L, Dhermain F, Alapetite C, Mammar H, Boisserie G, Habrand JL, Mazeron JJ. A treatment planning comparison of combined photon-proton beams versus proton beams-only for the treatment of skull base tumors. Int J Radiat Oncol Biol Phys 2007; 69:944-54. [PMID: 17889276 DOI: 10.1016/j.ijrobp.2007.07.2326] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2007] [Revised: 07/12/2007] [Accepted: 07/13/2007] [Indexed: 11/22/2022]
Abstract
PURPOSE To compare treatment planning between combined photon-proton planning (CP) and proton planning (PP) for skull base tumors, so as to assess the potential limitations of CP for these tumors. METHODS AND MATERIALS Plans for 10 patients were computed for both CP and PP. Prescribed dose was 67 cobalt Gray equivalent (CGE) for PP; 45 Gy (photons) and 22 CGE (protons) for CP. Dose-volume histograms (DVHs) were calculated for gross target volume (GTV), clinical target volume (CTV), normal tissues (NT), and organs at risk (OARs) for each plan. Results were analyzed using DVH parameters, inhomogeneity coefficient (IC), and conformity index (CI). RESULTS Mean doses delivered to the GTVs and CTVs with CP (65.0 and 61.7 CGE) and PP (65.3 and 62.2 Gy CGE) were not significantly different (p > 0.1 and p = 0.72). However, the dose inhomogeneity was drastically increased with CP, with a mean significant incremental IC value of 10.5% and CP of 6.8%, for both the GTV (p = 0.01) and CTV (p = 0.04), respectively. The CI(80%) values for the GTV and CTV were significantly higher with PP compared with CP. Compared with CP, the use of protons only led to a significant reduction of NT and OAR irradiation, in the intermediate-to-low dose (< or =80% isodose line) range. CONCLUSIONS These results suggest that the use of CP results in levels of target dose conformation similar to those with PP. Use of PP significantly reduced the tumor dose inhomogeneity and the delivered intermediate-to-low dose to NT and OARs, leading us to conclude that this treatment is mainly appropriate for tumors in children.
Collapse
Affiliation(s)
- Loïc Feuvret
- Institut Curie, Centre de Protonthérapie d'Orsay, Orsay Cedex, France.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
35
|
Chang J, Yenice KM, Narayana A, Gutin PH. Accuracy and feasibility of cone-beam computed tomography for stereotactic radiosurgery setup. Med Phys 2007; 34:2077-84. [PMID: 17654911 DOI: 10.1118/1.2731031] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Image fusion, target localization, and setup accuracy of cone-beam computed tomography (CBCT) for stereotactic radiosurgery (SRS) were investigated in this study. A Rando head phantom rigidly attached to a stereotactic Brown-Roberts-Wells (BRW) frame was utilized to study the geometric accuracy of CBCT. Measurements of distances and angular separations between selected pairs of multiple radio-opaque targets embedded in the head phantom from a conventional simulation CT provided comparative data for geometric accuracy analysis. Localization accuracy of the CBCT scan was investigated from an analysis of BRW localization of four cylindrical objects (9 mm in diameter and 25 mm in length) independently computed from CBCT and conventional CT scans. Image fusion accuracy was quantitatively evaluated from BRW localization of multiple simulated targets from the CBCT and conventional CT scan. Finally, a CBCT setup procedure for stereotactic radiosurgery treatments was proposed and its accuracy was assessed using orthogonal target verification imaging. Our study showed that CBCT did not present any significant geometric distortions. Stereotactic coordinates of the four cylindrical objects as determined from the CBCT differed from those determined from the conventional CT on average by 0.30 mm with a standard deviation (SD) of 0.09 mm. The mean image registration accuracy of CBCT with conventional CT was 0.28 mm (SD = 0.10 mm). Setup uncertainty of our proposed CBCT setup procedure was on the same order as the conventional framed-based stereotactic systems reported in the literature (mean = 1.34 mm, SD = 0.33 mm). In conclusion, CBCT can be used to guide SRS treatment setup with accuracy comparable to the currently used frame-based stereotactic radiosurgery systems provided that intra-treatment patient motion is prevented.
Collapse
Affiliation(s)
- Jenghwa Chang
- Medical Physics Department, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10021, USA.
| | | | | | | |
Collapse
|
36
|
Koh ES, Millar BA, Ménard C, Michaels H, Heydarian M, Ladak S, McKinnon S, Rutka JA, Guha A, Pond GR, Laperriere NJ. Fractionated stereotactic radiotherapy for acoustic neuroma. Cancer 2007; 109:1203-10. [PMID: 17318817 DOI: 10.1002/cncr.22499] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The clinical outcome and toxicity of fractionated stereotactic radiotherapy (FSRT) was assessed for acoustic neuroma in 60 patients treated in a single institution. METHODS Between October 1996 and February 2005, 60 patients received FSRT for acoustic neuroma (AN). The mean total dose applied was 50 Gy in single daily 2-Gy fractions over 5 weeks. The median irradiated tumor volume was 4.9 cm(3) (range, 0.3-49.0 cm(3)). The median follow-up period was 31.9 months. RESULTS FSRT was well tolerated in all patients. The 5-year actuarial local control rate was 96.2% (95% CI: 91.1%-100.0%). Five-year actuarial progression-free survival was 92.8% (95% CI: 84.8%-100.0%). The overall hearing preservation rate was 77.3%. Five of 6 patients with initial cranial nerve V (CNV) numbness remained stable post-FSRT. Two of 3 patients with baseline trigeminal neuralgia improved with the remaining patient stable. All 3 patients with nonsurgically related facial nerve weakness either improved or achieved stability in function. There were no cases of new cranial nerve toxicity post-FSRT. CONCLUSIONS FSRT for the treatment of AN is safe, effective, and well tolerated. FSRT should thus be considered as an effective alternative treatment modality when compared with microsurgical resection or single fraction stereotactic radiosurgery.
Collapse
Affiliation(s)
- Eng-Siew Koh
- Department of Radiation Oncology, University of Toronto, Princess Margaret Hospital, Toronto, Ontario, Canada
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Narayana A, Chang J, Yenice K, Chan K, Lymberis S, Brennan C, Gutin PH. Hypofractionated stereotactic radiotherapy using intensity-modulated radiotherapy in patients with one or two brain metastases. Stereotact Funct Neurosurg 2006; 85:82-7. [PMID: 17167236 DOI: 10.1159/000097923] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
PURPOSE A small fraction of patients with 1-2 brain metastases will not be suitable candidates to either surgical resection or stereotactic radiosurgery (SRS) due to either their location or their size. The objective of this study was to determine the local control, survival, patterns of relapse and the incidence of brain injury following a course of hypofractionated stereotactic radiotherapy while avoiding upfront whole brain radiation therapy (WBRT) in this subgroup of patients. METHODS A Gill-Thomas removable head frame system was used for immobilization. Brain LAB software with dynamic multileaf collimator hardware was used to design and deliver an intensity-modulated radiation therapy treatment plan. A dose of 600 cGy was prescribed to the 100% isodose line that would encompass the lesion with a 3-mm margin. A total dose of 3,000 cGy was delivered in 5 fractions using 2 fractions per week. The patients were followed with neurological examination and serial MRI images done every 3 months following the procedure. RESULTS Twenty patients have been treated using this fractionation schedule since April 2004. The 1-year local control at the site of original disease is 70%. The complete response, partial response and stable disease at the last follow-up were 15, 30 and 45%, respectively. Two patients had local recurrence at the site of original disease, while 5 had evidence of leptomeningeal disease. Two additional patients developed new brain metastases, resulting in a 1-year brain relapse-free survival of 36% following this approach. The median overall survival was 8.5 months. Three patients (15%) developed steroid dependency lasting 3 months or longer following the procedure. Four patients (20%) needed WBRT as salvage following this approach. CONCLUSIONS The preliminary results of hypofractionated SRS are comparable to both surgery and SRS data for solitary brain metastases in terms of local control and overall survival with acceptable morbidity in this cohort of unfavorable patients.
Collapse
Affiliation(s)
- Ashwatha Narayana
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Weill Medical College of Cornell University, New York, NY, USA.
| | | | | | | | | | | | | |
Collapse
|
38
|
Andrews DW, Bednarz G, Evans JJ, Downes B. A review of 3 current radiosurgery systems. ACTA ACUST UNITED AC 2006; 66:559-64. [PMID: 17145309 DOI: 10.1016/j.surneu.2006.08.002] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2005] [Accepted: 07/21/2006] [Indexed: 11/18/2022]
Abstract
BACKGROUND Stereotactic radiosurgery and fractionated stereotactic radiotherapy have become widespread techniques applied to the treatment of a variety of intracranial lesions. Rapid evolution of new technologies has now enabled clinicians to treat tumors outside the cranium and down the spinal axis. This review compares 3 commercially available systems in widespread use throughout the world. METHODS Literature review and interviews with practitioners in the United States were performed to establish data for a comparative analysis of the Gamma Knife (Elekta, Sweden), Novalis (BrainLabs, Germany), and CyberKnife systems (Accuray, Sunnyvale, CA). Cost analyses were deliberately excluded because of the need for detailed cost-benefit analysis beyond the scope of the review. RESULTS An unbiased comparative analysis was not possible because of the lack of objective data from a standard metric for these systems. Despite this shortcoming, disparate features of each system were compared and contrasted. CONCLUSION A careful assessment of each system, including its operational features, capabilities, and yearly capacity must be weighed against the composition of the radiosurgery team, the case mix of the practice, and the objectives of the clinical unit to yield the best fit.
Collapse
Affiliation(s)
- David W Andrews
- Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, PA 19107, USA.
| | | | | | | |
Collapse
|
39
|
Deloar HM, Kunieda E, Kawase T, Tsunoo T, Saitoh H, Ozaki M, Saito K, Takagi S, Sato O, Fujisaki T, Myojoyama A, Sorell G. Investigations of different kilovoltage x-ray energy for three-dimensional converging stereotactic radiotherapy system: Monte Carlo simulations with CT data. Med Phys 2006; 33:4635-42. [PMID: 17278816 DOI: 10.1118/1.2361080] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
We are investigating three-dimensional converging stereotactic radiotherapy (3DCSRT) with suitable medium-energy x rays as treatment for small lung tumors with better dose homogeneity at the target. A computed tomography (CT) system dedicated for non-coplanar converging radiotherapy was simulated with BEAMnrc (EGS4) Monte-Carlo code for x-ray energy of 147.5, 200, 300, and 500 kilovoltage (kVp). The system was validated by comparing calculated and measured percentage of depth dose in a water phantom for the energy of 120 and 147.5 kVp. A thorax phantom and CT data from lung tumors (<20 cm3) were used to compare dose homogeneities of kVp energies with MV energies of 4, 6, and 10 MV. Three non-coplanar arcs (0 degrees and +/-25 degrees ) around the center of the target were employed. The Monte Carlo dose data format was converted to the XiO RTP format to compare dose homogeneity, differential, and integral dose volume histograms of kVp and MV energies. In terms of dose homogeneity and DVHs, dose distributions at the target of all kVp energies with the thorax phantom were better than MV energies, with mean dose absorption at the ribs (human data) of 100%, 85%, 50%, 30% for 147.5, 200, 300, and 500 kVp, respectively. Considering dose distributions and reduction of the enhanced dose absorption at the ribs, a minimum of 500 kVp is suitable for the lung kVp 3DCSRT system.
Collapse
Affiliation(s)
- Hossain M Deloar
- Department of Radiology, Keio University, Tokyo, Japan and CREST, Japan Science and Technology Agency, Tokyo, Japan
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Georg D, Bogner J, Dieckmann K, Pötter R. Is mask-based stereotactic head-and-neck fixation as precise as stereotactic head fixation for precision radiotherapy? Int J Radiat Oncol Biol Phys 2006. [DOI: 10.1016/j.ijrobp.2006.05.075] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
41
|
Yenice KM, Narayana A, Chang J, Gutin PH, Amols HI. Intensity-modulated stereotactic radiotherapy (IMSRT) for skull-base meningiomas. Int J Radiat Oncol Biol Phys 2006. [DOI: 10.1016/j.ijrobp.2005.09.040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
42
|
Yin FF, Das S, Kirkpatrick J, Oldham M, Wang Z, Zhou SM. Physics and imaging for targeting of oligometastases. Semin Radiat Oncol 2006; 16:85-101. [PMID: 16564444 DOI: 10.1016/j.semradonc.2005.12.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Oligometastases refer to metastases that are limited in number and location and are amenable to regional treatment. The majority of these metastases appear in the brain, lung, liver, and bone. Although the focus of interest in the past within radiation oncology has been on the treatment of intracranial metastases, there has been growing interest in extracranial sites such as the liver and lung. This is largely because of the rapid development of targeting techniques for oligometastases such as intensity-modulated and image-guided radiation therapy, which has made it possible to deliver single or a few fractions of high-dose radiation treatments, highly conformal to the target. The clinical decision to use radiation to treat oligometastases is based on both radiobiological and physics considerations. The radiobiological considerations involve improvement of treatment schema for time, dose, and volume. Areas of interests are hypofractionation, tumor and normal tissue tolerance, and hypoxia. The physics considerations for oligometastases treatment are focused mainly on ensuring treatment accuracy and precision. This article discusses the physics and imaging aspects involved in each step of the radiation treatment process for oligometastases, including target definition, treatment simulation, treatment planning, pretreatment target localization, radiation delivery, treatment verification, and treatment evaluation.
Collapse
Affiliation(s)
- Fang-Fang Yin
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710, USA.
| | | | | | | | | | | |
Collapse
|
43
|
Kunieda E, Deloar HM, Kitamura M, Kawaguchi O, Shiba H, Takeda A, Kawase T, Seki S, Shigematsu N, Kubo A. Rotational and translational reproducibility of newly developed Leksell frame-based relocatable fixation system. RADIATION MEDICINE 2006; 24:503-10. [PMID: 17058144 DOI: 10.1007/s11604-006-0066-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2005] [Accepted: 05/18/2006] [Indexed: 05/12/2023]
Abstract
PURPOSE The aim of this study was to evaluate three-dimensional movement of the cranium in a relocatable frame using positions of anatomical landmarks obtained from repeated quality-assurance (QA) computed tomography (CT) studies. MATERIALS AND METHODS We analyzed 17 series of QA-CT data representing five patients who underwent stereotactic radiotherapy for treatment of acoustic neurinoma. Helical-CT scans with 1-mm collimation were obtained at the time of treatment planning and during the course of treatment. The right and left short processes of the incus and the top of the crista galli were used as the three anatomical reference points. RESULTS Fluctuations in distance among the reference points were all <1 mm. The translational displacements for these points were <2 mm, with standard deviations (SD) of <2 mm. A plane that included all three reference points was defined as the reference plane. To investigate the direction of cranial rotation for each QA-CT scan, unit normal vectors of the reference plane were obtained. Three-dimensional analyses indicated that cranial rotation was greatest along the X-axis, followed by the Y-axis, with the least rotation along the Z-axis. CONCLUSION The result suggested that movement of the craniocaudal axis in the sagittal plane was a major factor behind displacement of the cranium.
Collapse
Affiliation(s)
- Etsuo Kunieda
- Department of Radiology, Keio University, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Higgins PD, Gerbi BJ, Macedon M, Dusenbery KE. Fractionated stereotactic radiotherapy for pediatric patients with retinoblastoma. J Appl Clin Med Phys 2006; 7:9-17. [PMID: 17533322 PMCID: PMC5722448 DOI: 10.1120/jacmp.v7i2.2161] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2005] [Revised: 01/26/2006] [Accepted: 12/31/1969] [Indexed: 12/04/2022] Open
Abstract
In this report, we discuss the application of a modified Gill‐Thomas‐Cosman (GTC) relocatable head frame to enable fractionated stereotactic radiotherapy (SRT) of infants under anesthesia. This system has been used to treat two infants, ages 12 and 18 months, for bilateral retinoblastoma on a Varian 6/100 linear accelerator. The GTC head frame was used to reproducibly position and treat the orbits of these children to between 2520 cGy and 3960 cGy in 180‐cGy fractions. A standard head and neck tray, with accompanying thermoplastic mask, was adapted to mount to the head frame to enable these treatments. We found the maximum average deviation in the repeat fixations, as compared with the initial fitting data, to be ±2mm. The overall average difference and standard deviation in measurement was 0.47±0.63mm for the first case and 0.19±0.94mm for the second case, with a combined average of 0.35±0.79mm overall from a total of 381 point measurements. The stereotactic treatment plan (Radionics®) incorporated a single isocenter for each orbit and 3 or 4 arcs per isocenter. An intercomparison has been made between this technique and a standard lateral field technique, designed using the stereotactic radiosurgery (SRS) planning system. Dose‐volume histograms and corresponding normal tissue complication probabilities (NTCP) based on pediatric bone growth inhibition have been calculated for each method for the orbital bone areas. We found that the NTCP is reduced from 95% or more in the standard treatment method to 16% or less with SRT. Use of the modified head frame provides excellent setup reproducibility, facilitates access to patients for anesthesia, and reduces the chances of a poor cosmetic result in these growing children. PACS number: 87.53.Ly
Collapse
Affiliation(s)
- Patrick D Higgins
- Department of Therapeutic Radiology-Radiation Oncology, University of Minnesota, Minneapolis, Minnesota 55455, USA.
| | | | | | | |
Collapse
|
45
|
Li S, Liu D, Yin G, Zhuang P, Geng J. Real-time 3D-surface-guided head refixation useful for fractionated stereotactic radiotherapy. Med Phys 2006; 33:492-503. [PMID: 16532957 DOI: 10.1118/1.2150778] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Accurate and precise head refixation in fractionated stereotactic radiotherapy has been achieved through alignment of real-time 3D-surface images with a reference surface image. The reference surface image is either a 3D optical surface image taken at simulation with the desired treatment position, or a CT/MRI-surface rendering in the treatment plan with corrections for patient motion during CT/MRI scans and partial volume effects. The real-time 3D surface images are rapidly captured by using a 3D video camera mounted on the ceiling of the treatment vault. Any facial expression such as mouth opening that affects surface shape and location can be avoided using a new facial monitoring technique. The image artifacts on the real-time surface can generally be removed by setting a threshold of jumps at the neighboring points while preserving detailed features of the surface of interest. Such a real-time surface image, registered in the treatment machine coordinate system, provides a reliable representation of the patient head position during the treatment. A fast automatic alignment between the real-time surface and the reference surface using a modified iterative-closest-point method leads to an efficient and robust surface-guided target refixation. Experimental and clinical results demonstrate the excellent efficacy of <2 min set-up time, the desired accuracy and precision of <1 mm in isocenter shifts, and <1 degree in rotation.
Collapse
Affiliation(s)
- Shidong Li
- Department of Radiation Oncology and Molecular Radiation Science, Johns Hopkins University School of Medicine, USA.
| | | | | | | | | |
Collapse
|
46
|
Engelsman M, Rosenthal SJ, Michaud SL, Adams JA, Schneider RJ, Bradley SG, Flanz JB, Kooy HM. Intra- and interfractional patient motion for a variety of immobilization devices. Med Phys 2006; 32:3468-74. [PMID: 16372417 DOI: 10.1118/1.2089507] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The magnitude of inter- and intrafractional patient motion has been assessed for a broad set of immobilization devices. Data was analyzed for the three ordinal directions--left-right (x), sup-inf (y), and ant-post (z)--and the combined spatial displacement. We have defined "rigid" and "non-rigid" immobilization devices depending on whether they could be rigidly and reproducibly connected to the treatment couch or not. The mean spatial displacement for intrafractional motion for rigid devices is 1.3 mm compared to 1.9 mm for nonrigid devices. The modified Gill-Thomas-Cosman frame performed best at controlling intrafractional patient motion, with a 95% probability of observing a three-dimensional (3D) vector length of motion (v95) of less than 1.8 mm, but could not be evaluated for interfractional motion. All other rigid and nonrigid immobilization devices had a v95 of more than 3 mm for intrafractional patient motion. Interfractional patient motion was only evaluated for the rigid devices. The mean total interfractional displacement was at least 3.0 mm for these devices while v95 was at least 6.0 mm.
Collapse
Affiliation(s)
- Martijn Engelsman
- Northeast Proton Therapy Center, Massachusetts General Hospital and Department of Radiation Oncology, Harvard Medical School, 55 Fruit Street, Boston, Massachusetts 02114, USA
| | | | | | | | | | | | | | | |
Collapse
|
47
|
Abstract
In summary, much progress has been made in our understanding of childhood craniopharyngiomas. These histologically benign but "geographically malignant" tumors are challenging to treat and require experienced clinicians from multiple disciplines including neurosurgery, radiology, hematology/oncology, ophthalmology, endocrinology, and general pediatrics to address the multiple issues that arise with diagnosis, treatment, and long-term follow-up of affected children. The study and close observation of patients who have craniopharyngiomas may also be beneficial for our general understanding of pathophysiologic processes such as the observed "growth without growth hormone" phenomenon or the well-described and studied hypothalamic obesity phenotypes.
Collapse
Affiliation(s)
- Joshua A May
- Division of Endocrinology, Diabetes, and Metabolism, Childrens Hospital Los Angeles, Keck School of Medicine, University of Southern California, 4650 Sunset Boulevard, MS #61, Los Angeles, CA 90027, USA.
| | | | | | | |
Collapse
|
48
|
Yock TI, Tarbell NJ. Technology insight: Proton beam radiotherapy for treatment in pediatric brain tumors. ACTA ACUST UNITED AC 2005; 1:97-103; quiz 1 p following 111. [PMID: 16264827 DOI: 10.1038/ncponc0090] [Citation(s) in RCA: 56] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2004] [Accepted: 10/28/2004] [Indexed: 11/08/2022]
Abstract
Tumors of the central nervous system are the most common solid tumor in childhood. Treatment options for childhood brain tumors include radiation therapy, surgery and chemotherapy, often given in combination. Radiation therapy regularly has a pivotal role in treatment, and technological advancements during the past quarter of a century have dramatically improved the ability to deliver radiation in a more focused manner. Improvements in imaging and computing ability led to better targeting of tumor tissue using conventional X-ray therapy. These advances have been harnessed for proton radiation therapy. Proton radiotherapy has special physical characteristics that allow normal tissues to be spared better than even the most conformal photon radiation, and it will reduce the complications from treatment. This review discusses the characteristics of proton radiation, and describes examples of pediatric brain tumor patients who would benefit most from this form of treatment.
Collapse
Affiliation(s)
- Torunn I Yock
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA 02114, USA.
| | | |
Collapse
|
49
|
Muller K, Nowak PJCM, de Pan C, Marijnissen JP, Paridaens DA, Levendag P, Luyten GPM. Effectiveness of fractionated stereotactic radiotherapy for uveal melanoma. Int J Radiat Oncol Biol Phys 2005; 63:116-22. [PMID: 16111579 DOI: 10.1016/j.ijrobp.2005.01.058] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2004] [Revised: 01/04/2005] [Accepted: 01/12/2005] [Indexed: 10/25/2022]
Abstract
PURPOSE To study the effectiveness and acute side effects of fractionated stereotactic radiation therapy (fSRT) for uveal melanoma. METHODS AND MATERIALS Between 1999 and 2003, 38 patients (21 male, 17 female) were included in a prospective, nonrandomized clinical trial (mean follow-up of 25 months). A total dose of 50 Gy was given in 5 consecutive days. A blinking light and a camera (to monitor the position of the diseased eye) were fixed to a noninvasive relocatable stereotactic frame. Primary end points were local control, best corrected visual acuity, and toxicity at 3, 6, 12, and 24 months, respectively. RESULTS After 3 months (38 patients), the local control was 100%; after 12 months (32 patients) and 24 months (15 patients), no recurrences were seen. The best corrected visual acuity declined from a mean of 0.21 at diagnosis to 0.06 2 years after therapy. The acute side effects after 3 months were as follows: conjunctival symptoms (10), loss of lashes or hair (6), visual symptoms (5), fatigue (5), dry eye (1), cataract (1), and pain (4). One eye was enucleated at 2 months after fSRT. CONCLUSIONS Preliminary results demonstrate that fSRT is an effective and safe treatment modality for uveal melanoma with an excellent local control and mild acute side effects. The follow-up should be prolonged to study both long-term local control and late toxicity.
Collapse
Affiliation(s)
- Karin Muller
- Department of Radiation Oncology, Erasmus Medical Center, Rotterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
50
|
Giller CA, Berger BD, Pistenmaa DA, Sklar F, Weprin B, Shapiro K, Winick N, Mulne AF, Delp JL, Gilio JP, Gall KP, Dicke KA, Swift D, Sacco D, Harris-Henderson K, Bowers D. Robotically guided radiosurgery for children. Pediatr Blood Cancer 2005; 45:304-10. [PMID: 15558704 DOI: 10.1002/pbc.20267] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
BACKGROUND A robotically guided linear accelerator has recently been developed which provides frameless radiosurgery with high precision. Potential advantages for the pediatric population include the avoidance of the cognitive decline associated with whole brain radiotherapy, the ability to treat young children with thin skulls unsuitable for frame-based methods, and the possible avoidance of general anesthesia. We report our experience with this system (the "Cyberknife") in the treatment of 21 children. PROCEDURES Cyberknife radiosurgery was performed on 38 occasions for 21 patients, age ranging from 8 months to 16 years (7.0 +/- 5.1 years), with tumors considered unresectable. Three had pilocytic astrocytomas, two had anaplastic astrocytomas, three had ependymomas (two anaplastic), four had medulloblastomas, three had atypical teratoid/rhabdoid tumors, three had craniopharyngiomas, and three had other pathologies. The mean target volume was 10.7 +/- 20 cm(3), mean marginal dose was 18.8 +/- 8.1 Gy, and mean follow-up is 18 +/- 11 months. Twenty-seven (71%) of the treatments were single-shot and eight (38%) patients did not require general anesthesia. RESULTS Local control was achieved in the patients with pilocytic and anaplastic astrocytoma, three of the patients with medulloblastoma, and the three with craniopharyngioma, but not for those with ependymoma. Two of the patients with rhabdoid tumors are alive 16 and 35 months after this diagnosis. There have been no procedure related deaths or complications. CONCLUSION Cyberknife radiosurgery can be used to achieve local control for some children with CNS tumors without the need for rigid head fixation.
Collapse
Affiliation(s)
- Cole A Giller
- Baylor University Medical Center, HTPN, 8080 N. Central Expressway, Ste. 1650, Dallas, TX 75206, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|