1
|
Hossain MS, Khaleque MA, Ali MR, Bacchu MS, Hossain MI, Aly Saad Aly M, Khan MZH. Poly(3,4-ethylenedioxythiophene):Polystyrene Sulfonate-Modified Electrode for the Detection of Furosemide in Pharmaceutical Products. ACS OMEGA 2023; 8:16851-16858. [PMID: 37214665 PMCID: PMC10193417 DOI: 10.1021/acsomega.3c00463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 04/19/2023] [Indexed: 05/24/2023]
Abstract
Furosemide (4-chloro-2-(furan-2-ylmethylamino)-5-sulfamoyl benzoic acid) is a widely used, FDA-approved drug prescribed for several symptoms associated with heart, kidney, liver failure, or chronic high blood pressure. In this work, a glassy carbon working electrode modified with poly(3,4-ethylenedioxythiophene):polystyrene sulfonate is developed to detect furosemide (FURO) with high sensitivity and precise selectivity. The modified electrode was also characterized using field emission scanning electron microscopy, attenuated total reflectance-Fourier transform infrared, and cyclic voltammetry. Here, an efficient and cost- and time-efficient technique to study the furosemide mechanism of reaction in an acidic liquid medium is presented. An electrochemical oxidation of loop diuretic furosemide was investigated in a supporting electrolyte, 0.01 M of phosphate buffer (at a pH level of 4.0) at 25 ± 0.1 °C using a differential pulse voltammetric (DPV) technique. Under optimized parameters, the developed sensor displays a wide detection range of furosemide concentrations of 6.0 × 10-6 to 1.0 × 10-4 M with a detection limit of 2.0 × 10-6 M using DPV. The presented sensor offers a robust and high-precision technique with an excellent reproducibility to detect furosemide in as a real sample such as urine and pharmaceutical products.
Collapse
Affiliation(s)
- Md. Shamim Hossain
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Md. Abdul Khaleque
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Md. Romzan Ali
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Md. Sadek Bacchu
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Md. Ikram Hossain
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| | - Mohamed Aly Saad Aly
- Department
of Electrical and Computer Engineering at Georgia Tech Shenzhen Institute
(GTSI), Tianjin University, Shenzhen, Guangdong 518052, China
| | - Md. Zaved Hossain Khan
- Department
of Chemical Engineering, Jashore University
of Science and Technology, Jashore 7408, Bangladesh
- Laboratory
of Nano-Bio and Advanced Materials Engineering (NAME), Jashore University of Science and Technology, Jashore 7408, Bangladesh
| |
Collapse
|
2
|
Al-Hashimi NN, El-Sheikh AH, Alruwad MI, Odeh MM. Solvent bar microextraction combined with HPLC-DAD for simultaneous determination of diuretics in human urine and plasma samples. Curr Pharm Biotechnol 2021; 23:1204-1213. [PMID: 33618643 DOI: 10.2174/1389201022666210222111943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 01/01/2021] [Accepted: 01/11/2021] [Indexed: 11/22/2022]
Abstract
BACKGROUND A simple and powerful microextraction procedure, the solvent bar microextraction (SBME), was used for the simultaneous determination of two diuretics, furosemide and spironolactone in human urine and plasma samples, using high-performance liquid chromatography coupled with diode array detection (HPLC-DAD). METHODS The appropriate amount (2 µL) of 1-octanol as an organic solvent confined within (2.5 cm) of a porous hollow fiber micro-tube, sealed at both ends was used for this procedure. The conditions for the SBME were optimized in water and the analytical performance were examined in spiked human urine and plasma samples. RESULTS The optimized method exhibited good linearity (R2 > 0.997) over the studied range of higher than 33 to 104 µg L-1 for furosemide and spironolactone in urine and plasma samples, illustrating a satisfactory precision level with RSD values between 2.1% and 9.1%. DISCUSSION The values of the limits of detection were found to be in the range of 6.39 to 9.67 µg L-1, and extraction recovery˃ 58.8% for both diuretics in urine and plasma samples. The applicability and effectiveness of the proposed method for the determination of furosemide and spironolactone in patient urine samples were tested. CONCLUSION In comparison with reference methods, the attained results demonstrated that SBME combined with HPLC-DAD was proved to be simple, inexpensive, and promising analytical technology for the simultaneous determination of furosemide and spironolactone in urine and plasma samples.
Collapse
Affiliation(s)
- Nabil N Al-Hashimi
- The Hashemite University, Faculty of Pharmaceutical Sciences, Department of Pharmaceutical Chemistry, P.O. Box 330127, Al-Zarqa 13133. Jordan
| | - Amjad H El-Sheikh
- The Hashemite University, Faculty of Science, Department of Chemistry, P.O. Box 150459, Al-Zarqa 13115. Jordan
| | - Manal I Alruwad
- The Hashemite University, University Health Center, P.O. Box 330127, Al-Zarqa 13133. Jordan
| | - Mohanad M Odeh
- The Hashemite University, Faculty of Pharmaceutical Sciences, Department of Clinical Pharmacy and Pharmacy Practice, P.O. Box 330127, Al-Zarqa 13133. Jordan
| |
Collapse
|
3
|
Vasconcelos SC, Rodrigues EM, de Almeida LG, Lepri FG, Pacheco WF, Semaan FS, Dornellas RM. An improved drop casting electrochemical strategy for furosemide quantification in natural waters exploiting chemically reduced graphene oxide on glassy carbon electrodes. Anal Bioanal Chem 2020; 412:7123-7130. [PMID: 32737552 DOI: 10.1007/s00216-020-02845-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 07/16/2020] [Accepted: 07/23/2020] [Indexed: 11/28/2022]
Abstract
This work exploits the applicability of a chemically reduced graphene oxide (CRGO) modification on the electrochemical response of a glassy carbon electrode (GCE) for the first-time sensitive determination of furosemide in natural waters. The batch injection analysis (BIA) is proposed as an analytical method, where CRGO-GCE is coupled to a BIA cell for amperometric measurements. Acetate buffer (0.1 μmol L-1, pH 5.2) was used as the background electrolyte. The modification provided an increase in sensitivity (0.024 μA/μmol L-1), low limit of detection (0.7 μmol L-1), RSD (< 4%), and broad linear range (1-600 μmol L-1). Recovery tests performed in two different concentration ranges resulted in values between 89 and 99%. Recovery tests were performed and compared with high-performance liquid chromatography (HPLC) with UV-Vis detection using Student's t test at a 95% significance level, and no significant differences were found, confirming the accuracy of the method. The developed method is proven faster (169 h-1) compared with the HPLC analysis (5 h-1), also comparable with other flow procedures hereby described, offering a low-cost strategy suitable to quantify an emerging pharmaceutical pollutant. Graphical abstract.
Collapse
Affiliation(s)
- Sancler C Vasconcelos
- Peter Sørensen Group of Analytical Chemistry, Institute of Chemistry, Fluminense Federal University, Niteroi, RJ, 24020-141, Brazil
| | - Eduardo M Rodrigues
- Peter Sørensen Group of Analytical Chemistry, Institute of Chemistry, Fluminense Federal University, Niteroi, RJ, 24020-141, Brazil
| | - Leonardo G de Almeida
- Peter Sørensen Group of Analytical Chemistry, Institute of Chemistry, Fluminense Federal University, Niteroi, RJ, 24020-141, Brazil
| | - Fábio G Lepri
- Peter Sørensen Group of Analytical Chemistry, Institute of Chemistry, Fluminense Federal University, Niteroi, RJ, 24020-141, Brazil
| | - Wagner F Pacheco
- Peter Sørensen Group of Analytical Chemistry, Institute of Chemistry, Fluminense Federal University, Niteroi, RJ, 24020-141, Brazil
| | - Felipe S Semaan
- Peter Sørensen Group of Analytical Chemistry, Institute of Chemistry, Fluminense Federal University, Niteroi, RJ, 24020-141, Brazil
| | - Rafael M Dornellas
- Peter Sørensen Group of Analytical Chemistry, Institute of Chemistry, Fluminense Federal University, Niteroi, RJ, 24020-141, Brazil.
| |
Collapse
|
4
|
Lustri WR, Lazarini SC, Lustri BC, Corbi PP, Silva MAC, Resende Nogueira FA, Aquino R, Amaral AC, Treu Filho O, Massabni AC, da Silva Barud H. Spectroscopic characterization and biological studies in vitro of a new silver complex with furosemide: Prospective of application as an antimicrobial agent. J Mol Struct 2017. [DOI: 10.1016/j.molstruc.2016.12.056] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
5
|
Bowen L, Mangan M, Haywood A, Glass B. Stability of Frusemide Tablets Repackaged in Dose Administration Aids. JOURNAL OF PHARMACY PRACTICE AND RESEARCH 2015. [DOI: 10.1002/j.2055-2335.2007.tb00738.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
| | - Martina Mangan
- School of Pharmacy and Molecular Sciences; James Cook University; Townsville
| | - Alison Haywood
- School of Pharmacy; Griffith University, Gold Coast Campus
| | - Beverley Glass
- School of Pharmacy and Molecular Sciences; James Cook University; Townsville Queensland
| |
Collapse
|
6
|
Luiz VHM, Pezza L, Pezza HR. Rapid determination of furosemide by combined spot test/diffuse reflectance spectroscopy to detect doping in sport. Microchem J 2013. [DOI: 10.1016/j.microc.2012.04.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
7
|
de Carvalho LM, Viana C, Moreira APL, do Nascimento PC, Bohrer D, Motta MJ, da Silveira GD. Pulsed amperometric detection (PAD) of diuretic drugs in herbal formulations using a gold electrode following ion-pair chromatographic separation. J Solid State Electrochem 2013. [DOI: 10.1007/s10008-013-2115-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
8
|
MALODE SHWETAJ, SHETTI NAGARAJP, NANDIBEWOOR SHARANAPPAT. Mechanistic aspects of Os(VIII) catalysed oxidation of loop diuretic drug furosemide by Ag(III) periodate complex in aqueous alkaline medium. J CHEM SCI 2012. [DOI: 10.1007/s12039-011-0182-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
9
|
Peralta CM, Fernández LP, Masi AN. A novel application of immobilization on membranes for the separation and spectrofluorimetric quantification of amiloride and furosemide in pharmaceutical samples. Anal Chim Acta 2010; 661:85-90. [DOI: 10.1016/j.aca.2009.12.015] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2009] [Revised: 12/09/2009] [Accepted: 12/11/2009] [Indexed: 11/30/2022]
|
10
|
Recent developments in analytical determination of furosemide. J Pharm Biomed Anal 2008; 48:519-32. [DOI: 10.1016/j.jpba.2008.07.003] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2008] [Revised: 07/01/2008] [Accepted: 07/02/2008] [Indexed: 11/23/2022]
|
11
|
Legorburu MJ, Alonso RM, Jiménez RM. DETERMINATION OF THE NON-THIAZIDE DIURETIC XIPAMIDE IN PHARMACEUTICALS AND URINE BY HPLC WITH AMPEROMETRIC DETECTION. J LIQ CHROMATOGR R T 2006. [DOI: 10.1081/jlc-100101695] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- M. J. Legorburu
- a Departamento de Química Analítica, Facultad de Ciencias , Universidad del País Vasco/EHU , Apdo. 644, Bilbao , 48080 , Spain
| | - R. M. Alonso
- a Departamento de Química Analítica, Facultad de Ciencias , Universidad del País Vasco/EHU , Apdo. 644, Bilbao , 48080 , Spain
| | - R. M. Jiménez
- a Departamento de Química Analítica, Facultad de Ciencias , Universidad del País Vasco/EHU , Apdo. 644, Bilbao , 48080 , Spain
| |
Collapse
|
12
|
José Ruiz‐Angel M, Berthod A, Carda‐Broch S, Celia García‐Álvarez‐Coque M. Analytical Techniques for Furosemide Determination. SEPARATION AND PURIFICATION REVIEWS 2006. [DOI: 10.1080/15422110600671726] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
13
|
Llorent-Martínez EJ, Ortega-Barrales P, Molina-Díaz A. Multicommuted flow-through fluorescence optosensor for determination of furosemide and triamterene. Anal Bioanal Chem 2005; 383:797-803. [PMID: 16211379 DOI: 10.1007/s00216-005-0079-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2005] [Revised: 08/16/2005] [Accepted: 08/23/2005] [Indexed: 10/25/2022]
Abstract
Multicommutation implemented with flow-through optosensors is a very promising area of research. This recent approach benefits from the advantages of both methods and results in high sensitivity, selectivity, and speed, and little waste generation. This paper reports the simultaneous determination of furosemide and triamterene, two widely used diuretics, by measurement of their native fluorescence. The system has been proved to be useful for determination of both analytes in pharmaceutical preparations and for determination of triamterene in human urine and serum. A minicolumn filled with Sephadex SPC-25 microbeads was used to achieve separation of both analytes before detection in a flow-through cell filled with the same resin. The sensor is linear in the range 50-1200 and 0.4-8 ng mL(-1) with detection limits of 15 and 0.1 ng mL(-1) for furosemide and triamterene, respectively.
Collapse
Affiliation(s)
- E J Llorent-Martínez
- Department of Physical and Analytical Chemistry, Faculty of Experimental Sciences, University of Jaén, Paraje Las Lagunillas, 23071 Jaén, Spain
| | | | | |
Collapse
|
14
|
Huclová J, Satínský D, Maia T, Karlícek R, Solich P, Araújo AN. Sequential injection extraction based on restricted access material for determination of furosemide in serum. J Chromatogr A 2005; 1087:245-51. [PMID: 16130720 DOI: 10.1016/j.chroma.2004.11.055] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Restricted access material (RAM) column containing 25 microm C18 alkyl-diol support was integrated into the sequential injection analysis (SIA) manifold and the SIA-RAM system was tested for direct determination of furosemide in serum. LiChrospher ADS column based on restricted access material is proposed to direct injection of biofluids. The integration of RAM material into SIA enabled creation of a comprehensive on-line sample clean-up technique combined with fluorescence quantitation of analyte. Centrifuged and diluted serum sample was aspirated into the system and loaded onto the column using acetonitrile-water (2:98), pH 2.7. The analyte was retained on the column while proteins contained in the sample were removed to the waste without precipitation and clogging the column. Interfering substances complicating the detection were washed out by acetonitrile-water (15:85), pH 2.7 in the next step. The extracted analyte was eluted by means of acetonitrile-water (25:75), pH 2.3 to the fluorescence detector (emission filter 385 nm). The whole procedure comprising sample pre-treatment, analyte detection and column reconditioning took 20 min. The recoveries of furosemide from serum lay between 101.4 and 103.4% for three concentrations of analyte.
Collapse
Affiliation(s)
- Jitka Huclová
- Department of Analytical Chemistry, Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
| | | | | | | | | | | |
Collapse
|
15
|
Guzmán A, Agüí L, Pedrero M, Yáñez-Sedeño P, Pingarrón JM. Flow injection and HPLC determination of furosemide using pulsed amperometric detection at microelectrodes. J Pharm Biomed Anal 2003; 33:923-33. [PMID: 14656583 DOI: 10.1016/s0731-7085(03)00422-9] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The flow-injection and HPLC determination of the diuretic drug furosemide using pulsed amperometric detection (PAD) at cylindrical carbon fibre microelectrodes (CFMEs) is reported. Experimental conditions such as pH (6.5) and buffer concentration (0.05 mol l(-1) HPO4(2-)/H2PO4(-)) were optimized using square-wave voltammetry (SWV). Repetitive flow-injection amperometric measurements at +1.25 V for furosemide showed a continuous decrease in the peak current, probably as a consequence of the microelectrode surface fouling. However, a suitable amperometric detection of furosemide was achieved using a PAD program consisting of a two-step potential waveform with alternating anodic and cathodic polarization. The anodic (detection) potential was +1.25 V (time of application 0.1 s), and the cathodic (cleaning) potential was -0.20 V (t=0.2 s). A linear calibration graph was obtained for furosemide in the 5.0 x 10(-7)-1.0 x 10(-4) mol l(-1) concentration range, with a limit of detection of 1.7 x 10(-7) mol l(-1). HPLC-PAD at carbon fibre microelectrodes was used for the determination of furosemide in the presence of several thiouracil drugs and oxytetracycline (OTC). The mobile phase selected was a 25:75 acetonitrile:5.0 x 10(-3) mol l(-1) NaH2PO4 (pH 5.0) mixture. A linear calibration graph was obtained for furosemide in the 1-100 microM range, with a limit of detection of 0.55 microM. The usefulness of this method for the determination of furosemide in real samples was evaluated by performing the analysis of commercial milk samples spiked with furosemide at a concentration level of 4.5 x 10(-7) mol l(-1) (150 ng ml(-1)), as well as with other thiouracil drugs and OTC. A mean recovery of 95+/-5% furosemide was obtained.
Collapse
Affiliation(s)
- Alicia Guzmán
- Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, 28040 Madrid, Spain
| | | | | | | | | |
Collapse
|
16
|
Effect of Ultrasonic Pretreatment on Analysis of Potassium Ion in Human Urine Using 15-Crown-5-Anthracene-based Membrane. JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE 2003. [DOI: 10.5012/jkcs.2003.47.1.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
17
|
Inés Toral M, Pope S, Quintanilla S, Richter P. Simultaneous determination of amiloride and furosemide in pharmaceutical formulations by first digital derivative spectrophotometry. Int J Pharm 2002; 249:117-26. [PMID: 12433440 DOI: 10.1016/s0378-5173(02)00482-9] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
This work presents a simple and fast method for the simultaneous determination of amiloride and furosemide by digital derivative spectrophotometry. HCl 1 x 10(-2) mol/l dissolved in ethanol was used as solvent and to extract drugs from formulations. Subsequently the samples were evaluated directly by first digital derivative spectrophotometry, using a smoothing factor of 8 and scale factor of 1 x 10(-4). The simultaneous determination of furosemide and amiloride can be carried out at 241.4 and 343.6 nm, respectively. In both cases, the zero crossing approach was used. When both compounds are present together in a sample, it is possible to quantify one in the presence of the other, without mutual interference. The determination range was found to be of 6.9 x 10(-8) to 16 x 10(-5) and 6.8 x 10(-8) to 8 x 10(-5) mol/l, for amiloride and furosemide, respectively. A good level of repeatability (RSD) of 0.9 and 0.6% was observed for amiloride and furosemide, respectively. The ingredients commonly found in commercial pharmaceutical formulations do not interfere. The proposed method was applied to the determination of these drugs in pharmaceutical formulations.
Collapse
Affiliation(s)
- M Inés Toral
- Department of Chemistry, University of Chile, P O Box 653, Santiago, Chile
| | | | | | | |
Collapse
|
18
|
Ferraro MC, Castellano PM, Kaufman TS. A spectrophotometric-partial least squares (PLS-1) method for the simultaneous determination of furosemide and amiloride hydrochloride in pharmaceutical formulations. J Pharm Biomed Anal 2001; 26:443-51. [PMID: 11489390 DOI: 10.1016/s0731-7085(01)00432-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A numerical method, based on the use of spectrophotometric data coupled to PLS-1 multivariate calibration, is reported for the simultaneous determination of furosemide and amiloride hydrochloride in synthetic samples and commercial tablets. The method was applied in the concentration ranges of 8.0-13.0 mg l(-1) for furosemide and 1.0-1.6 mg l(-1) for amiloride hydrochloride. Its accuracy and precision were determined, and it was validated by the analysis of synthetic mixtures of both drugs. The method was successfully applied to the quantitation of furosemide and amiloride hydrochloride in three different pharmaceutical formulations, providing results in agreement with those obtained by HPLC. It allowed the rapid, accurate and precise simultaneous estimation of the concentration of both analytes of interest in spite of their important spectral overlap, high concentration relationship and the presence of small amounts of different, unmodelled, absorbing excipients.
Collapse
Affiliation(s)
- M C Ferraro
- Area Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, (S2002LRK), Rosario, Argentina
| | | | | |
Collapse
|
19
|
Carda-Broch S, Esteve-Romero J, García-Alvarez-Coque MC. Furosemide assay in pharmaceuticals by Micellar liquid chromatography: study of the stability of the drug. J Pharm Biomed Anal 2000; 23:803-17. [PMID: 11022906 DOI: 10.1016/s0731-7085(00)00378-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
A simplified high-performance liquid chromatographic procedure is described for the determination of furosemide (4-chloro-N-furfuryl-5-sulphamoylanthranillic acid), which makes use of UV detection, a C18, reversed-phase column, and micellar mobile phases of sodium dodecyl sulphate (SDS) and 1-propanol at pH 3 buffered with phosphate system. The most adequate experimental conditions to handle furosemide solutions in the analytical laboratory are studied. The mixture of furosemide and its degradation products which are formed upon light exposition was resolved with a mobile phase of 0.04 M SDS-2% propanol. Separation of furosemide from its common impurities and the hydrolytic product, 4-chloro-5-sulphamoylanthranillic acid, was also possible. A mobile phase of larger elution strength, such as 0.06 M SDS-8%, propanol was preferred to assay furosemide in several dosage forms (tablets, capsules, injectables and drops). The validity of the procedure was checked by analysing 27 pharmaceuticals commercialised in several countries. The label claim percentages and coefficients of variation were in the 95-102% and 0.05-1.3% ranges, respectively. The results showed that the procedure is suitable for routine analysis of the diuretic.
Collapse
Affiliation(s)
- S Carda-Broch
- Department de Química Analítica, Facultat de Química, Universitat de València, Burjassot, Spain
| | | | | |
Collapse
|
20
|
Rao Y, Zhang X, Luo G, Baeyens WR. Chemiluminescence flow-injection determination of furosemide based on a rhodamine 6G sensitized cerium(IV) method. Anal Chim Acta 1999. [DOI: 10.1016/s0003-2670(99)00425-0] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
21
|
Lalljie SP, Barroso MB, Steenackers D, Alonso RM, Jiménez RM, Sandra P. Micellar electrokinetic chromatography as a fast screening method for the determination of the doping agents furosemide and piretanide in urine. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1997; 688:71-8. [PMID: 9029315 DOI: 10.1016/s0378-4347(97)88057-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The possibility of using micellar electrokinetic chromatography for the screening of the loop diuretics piretanide and furosemide in urine was studied. A fast and simple method with good repeatability is described. The method was applied to urine samples collected from a healthy volunteer after oral administration of therapeutic doses of each compound. Positive identification in the urine matrix was possible through recording diode array spectra.
Collapse
Affiliation(s)
- S P Lalljie
- Department of Organic Chemistry, University of Ghent, Belgium
| | | | | | | | | | | |
Collapse
|