1
|
Izoe Y, Nagao M, Sato K, Sakai A, Ando K, Kanai M, Yamamoto A, Sakai S, Chida K. Dynamic coronary CT Angiography-Estimated coronary flow in Non-Obstructive, Plaque-free coronary Arteries: Association with dyslipidemia and diabetes. IJC HEART & VASCULATURE 2022; 42:101098. [PMID: 36032266 PMCID: PMC9399286 DOI: 10.1016/j.ijcha.2022.101098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2022] [Revised: 07/09/2022] [Accepted: 07/25/2022] [Indexed: 11/18/2022]
Abstract
Rationale and Objectives In this study, we implemented dynamic coronary CT angiography (CCTA) in order to estimate the coronary flow rate in morphologically normal coronary arteries as well as to identify factors affecting the coronary flow rate. Materials and Methods We retrospectively enrolled 95 consecutively presenting patients without stenosis or plaque in their major coronary arteries on CCTA conducted with a 320-detector scanner (mean age, 57 years; 43 % men). Time-attenuation curves of the distal sites of the major coronary arteries and the aortic root were extracted from dynamic CCTA data. Coronary flow rate, an indicator of coronary blood flow, was calculated via a convolution-integration method integrating the two curves. Patients with dyslipidemia were divided according to the presence or absence of familial hypercholesterolemia (FH) as well as according to the receipt of statin therapy. Results We found that the coronary flow rate was statistically significantly lower in statin-naïve patients with dyslipidemia (n = 27, 0.56 ± 0.10) than in patients without dyslipidemia (n = 32, 0.64 ± 0.10, p = 0.0013). In FH (n = 26), the coronary flow rate was statistically significantly lower in statin-naïve patients (n = 7, 0.65 ± 0.08) than in those taking statins (n = 19, 0.72 ± 0.10, p = 0.0221). Coronary flow rate likewise exhibited a statistically significant negative correlation with hemoglobin A1c (Pearson r, −0.437; p = 0.0003), but no correlation with other coronary risk factors. The coronary flow rate was statistically significantly lower in patients with diabetes (n = 14, 0.55 ± 0.10) than in those without diabetes (n = 81, 0.61 ± 0.11, p = 0.0461). Conclusion We found a reduction in coronary flow rate in patients with statin-naive dyslipidemia and diabetes, even within morphologically normal coronary arteries.
Collapse
Affiliation(s)
- Yukako Izoe
- Graduate School of Medicine, Health Sciences, Division of Radiological Examination and Technology Tohoku University, Sendai City, Japan
| | - Michinobu Nagao
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women’s Medical University, Tokyo, Japan
- Corresponding author.
| | - Kayoko Sato
- Department of Cardiology, Tokyo Women’s Medical University, Tokyo, Japan
| | - Akiko Sakai
- Department of Cardiology, Tokyo Women’s Medical University, Tokyo, Japan
| | - Kiyoe Ando
- Department of Cardiology, Tokyo Women’s Medical University, Tokyo, Japan
| | - Miwa Kanai
- Department of Cardiology, Tokyo Women’s Medical University, Tokyo, Japan
| | - Astushi Yamamoto
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women’s Medical University, Tokyo, Japan
- Department of Cardiology, Tokyo Women’s Medical University, Tokyo, Japan
| | - Shuji Sakai
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women’s Medical University, Tokyo, Japan
| | - Koichi Chida
- Graduate School of Medicine, Health Sciences, Division of Radiological Examination and Technology Tohoku University, Sendai City, Japan
| |
Collapse
|
2
|
Matsuo Y, Nagao M, Yamamoto A, Ando K, Nakao R, Fukushima K, Momose M, Sakai A, Sato K, Sakai S. Coronary flow quantification estimated by dynamic 320-detector CT angiography: validation by 13N ammonia PET myocardial flow reserve. Br J Radiol 2021; 94:20201415. [PMID: 34586914 DOI: 10.1259/bjr.20201415] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
OBJECTIVES Resting coronary flow index (rCFI) estimated by 320-detector low-dose dynamic coronary CT angiography (CCTA) is a direct flow quantification using intracoronary attenuation. We propose modified-rCFI from new protocol combining dynamic scan and standard CCTA using dose-modulation, and validate its consistency with quantitative values and ischemia depicted by 13N-ammonia PET (NH3-PET). METHODS 46 patients who underwent dynamic CCTA and NH3-PET for coronary artery disease were evaluated using original rCFI in 21 patients and modified-rCFI in 25 patients. Two types of rCFI were calculated for three major coronary arteries. Myocardial blood flow (MBF) at rest and stress, myocardial flow reserve (MFR), and the presence or absence of ischemia for three major territories were depicted by NH3-PET. Coronary territories were categorized as territories with MFR <2.0, ≥2.0, or with and without ischemia. Receiver operating characteristic analysis was performed to determine the optimal cut-off of rCFI to distinguish territories with MFR <2.0 or the presence of ischemia. RESULTS rCFI and modified-rCFI had significant positive correlations with stress MBF and MFR. The optical cut-offs of rCFI and modified-rCFI of 0.39 and 0.61 could detect territories with MFR <2.0, with AUCs of 0.75 and 0.73, sensitivities of 48 and 34%, and specificities of 97 and 98%. Optimal cut-offs of rCFI and modified-rCFI distinguished ischemic segments from non-ischemic segments, with AUCs of 0.75 and 0.91, sensitivities of 53 and 50%, and specificities of 93 and 95%. CONCLUSION Two types of rCFI correlated with quantitative values from NH3-PET, and were consistent with a high specificity in detecting functional ischemia. ADVANCES IN KNOWLEDGE rCFI can contribute as additional functional test over standard CCTA in clinical work-up.
Collapse
Affiliation(s)
- Yuka Matsuo
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan.,Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Michinobu Nagao
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan
| | - Atsushi Yamamoto
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan
| | - Kiyoe Ando
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, Saitama, Japan
| | - Risako Nakao
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, Saitama, Japan
| | - Kenji Fukushima
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, Saitama, Japan
| | - Mitsuru Momose
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan
| | - Akiko Sakai
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Kayoko Sato
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Shuji Sakai
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan
| |
Collapse
|
3
|
Schroder J, Prescott E. Doppler Echocardiography Assessment of Coronary Microvascular Function in Patients With Angina and No Obstructive Coronary Artery Disease. Front Cardiovasc Med 2021; 8:723542. [PMID: 34778394 PMCID: PMC8585781 DOI: 10.3389/fcvm.2021.723542] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 09/22/2021] [Indexed: 01/18/2023] Open
Abstract
Echocardiographic evaluation is an essential part of the diagnostic work-up in patients with known or suspected cardiovascular disease. Transthoracic Doppler echocardiography (TTDE) enables straightforward and reliable visualization of flow in the left anterior descending artery. In the absence of obstructive coronary artery disease, low TTDE-derived coronary flow velocity reserve (CFVR) is considered a marker of coronary microvascular dysfunction (CMD). TTDE CFVR is free from ionizing radiation and widely available, utilizing high-frequency transducers, pharmacologic vasodilator stress, and pulsed-wave Doppler quantification of diastolic peak flow velocities. European Society of Cardiology guidelines recommend TTDE CFVR evaluation only following preceding anatomic invasive or non-invasive coronary imaging excluding obstructive CAD. Accordingly, clinical use of TTDE CFVR is limited and CMD frequently goes undiagnosed. An evolving body of evidence underlines that low CFVR is an important and robust predictor of adverse prognosis and continuing symptoms in angina patients both with and without obstructive CAD. The majority of angina patients have no obstructive CAD, particularly among women. This has led to the suggestion that there may be a gender-specific female atherosclerotic phenotype with less epicardial obstruction, and a low CFVR signifying CMD instead. Nevertheless, available evidence indicates low CFVR is an equally important prognostic marker in both men and women. In this review, TTDE CFVR was evaluated regarding indication, practical and technical aspects, and interpretation of results. Association with symptoms and prognosis, comparison with alternative invasive and non-invasive imaging modalities, and possible interventions in angina patients with low CFVR were discussed, and key research questions were proposed.
Collapse
Affiliation(s)
- Jakob Schroder
- Department of Cardiology, Bispebjerg Frederiksberg Hospital, University of Copenhagen, Copenhagen, Denmark
| | | |
Collapse
|
4
|
Corban M, Prasad A, Gulati R, Lerman L, Lerman A. Sex-specific differences in coronary blood flow and flow velocity reserve in symptomatic patients with non-obstructive disease. EUROINTERVENTION 2021; 16:1079-1084. [PMID: 31589144 PMCID: PMC9724856 DOI: 10.4244/eij-d-19-00520] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS Reduced coronary flow velocity reserve (CFVR) is associated with adverse cardiovascular outcomes. Whether CFVR and coronary blood flow (CBF) are similar in men and women with chest pain and non-obstructive CAD remains unknown. We hypothesised sex differences in CFVR and CBF. METHODS AND RESULTS A total of 1,683 patients with signs/symptoms of ischaemia and angiographically unobstructed coronary arteries (<40% angiographic stenosis) underwent coronary vasomotion evaluation. CFVR was measured as hyperaemic/resting average velocity in the LAD. Mid-LAD diameter was measured with quantitative angiography and CBF calculated at rest (rCBF) and hyperaemia (hCBF). Resting microvascular resistance (rMR) was calculated as mean arterial pressure/rCBF. Of the total number of patients, 1,096 (65%) were women, median age 51 [42, 59] years. Compared to men, women had lower median CFVR (2.7 [2.4, 3.2] vs 3.1 [2.7, 3.6], p<0.001), higher rCBF (49.7 [34.0, 71.1] vs 45.9 [31.8, 68.7] ml/min, p=0.04), lower hCBF (139.5 [93.0, 195.2] vs 147.1 [95.7, 218.6] ml/min, p=0.02), but similar rMR (p=0.82). Female sex was an independent predictor of lower CFVR, higher rCBF, and lower hCBF. CONCLUSIONS Compared to men, women with signs/symptoms of ischaemia and non-obstructive CAD have lower CFVR, higher rCBF, and lower hCBF. Female sex is a predictor of these sex-specific differences. The clinical diagnostic and prognostic implications of sex differences in coronary physiology need further evaluation.
Collapse
Affiliation(s)
- Michel Corban
- Department of Cardiovascular Diseases, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Abhiram Prasad
- Department of Cardiovascular Diseases, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Rajiv Gulati
- Department of Cardiovascular Diseases, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Lilach Lerman
- Department of Cardiovascular Diseases, Mayo Clinic College of Medicine and Science, Rochester, MN, USA,Division of Nephrology and Hypertension, Department of Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Amir Lerman
- Mayo Clinic, Division of Cardiovascular Diseases, 200 First Street SW, Rochester, MN 55905, USA. E-mail:
| |
Collapse
|
5
|
Godo S, Shimokawa H. Gender Differences in Endothelial Function and Coronary Vasomotion Abnormalities. GENDER AND THE GENOME 2020. [DOI: 10.1177/2470289720957012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Introduction: Structural and functional abnormalities of coronary microvasculature, referred to as coronary microvascular dysfunction (CMD), have been implicated in a wide range of cardiovascular diseases and have gained growing attention in patients with chest pain with no obstructive coronary artery disease, especially in females. The central mechanisms of coronary vasomotion abnormalities encompass enhanced coronary vasoconstrictive reactivity (ie, coronary spasm), reduced endothelium-dependent and -independent coronary vasodilator capacities, and increased coronary microvascular resistance. The 2 major endothelium-derived relaxing factors, nitric oxide (NO) and endothelium-dependent hyperpolarization (EDH) factors, modulate vascular tone in a distinct vessel size–dependent manner; NO mainly mediates vasodilatation of relatively large, conduit vessels, while EDH factors in small resistance vessels. Endothelium-dependent hyperpolarization–mediated vasodilatation is more prominent in female resistance arteries, where estrogens exert beneficial effects on endothelium-dependent vasodilatation via multiple mechanisms. In the clinical settings, therapeutic approaches targeting NO are disappointing for the treatment of various cardiovascular diseases, where endothelial dysfunction and CMD are substantially involved. Significance: In this review, we will discuss the current knowledge on the pathophysiology and molecular mechanisms of endothelial function and coronary vasomotion abnormalities from bench to bedside, with a special reference to gender differences. Results: Recent experimental and clinical studies have demonstrated distinct gender differences in endothelial function and coronary vasomotion abnormalities with major clinical implications. Moreover, recent landmark clinical trials regarding the management of stable coronary artery disease have questioned the benefit of percutaneous coronary intervention, supporting the importance of the coronary microvascular physiology. Conclusion: Further characterization and a better understanding of the gender differences in basic vascular biology as well as those in cardiovascular diseases are indispensable to improve health care and patient outcomes in cardiovascular medicine.
Collapse
Affiliation(s)
- Shigeo Godo
- Department of Cardiovascular Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Hiroaki Shimokawa
- Department of Cardiovascular Medicine, Tohoku University Graduate School of Medicine, Sendai, Japan
| |
Collapse
|
6
|
Hong J, Su M, Yu Y, Zhang Z, Liu R, Huang Y, Mu P, Zheng H, Qiu W. A Dual-Mode Imaging Catheter for Intravascular Ultrasound Application. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:657-663. [PMID: 30222555 DOI: 10.1109/tmi.2018.2869942] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Both the morphological anatomy and functional parameters such as flow speed of the artery provide valuable information for the evaluation of cardiovascular diseases. Direct measurement of the arterial wall can be achieved by intravascular optical/ultrasound imaging methods, and however, no functional data are acquired with these methods. Fractional flow reserve and Doppler wire have been used to assess the blood flow information, but do not provide cross-sectional images of the artery. This paper is the first to design and fabricate a dual-mode imaging catheter that contains a forward-looking ultrasonic transducer and a side-looking ultrasonic transducer together in one catheter. This dual-mode catheter not only provides morphological information about the artery, but also a precise measurement of functional flow. The data indicate that the proposed catheter can be used to acquire multiple parameters of the artery with a one-time procedure. This novel one-catheter approach could be used for the functional diagnosis of atherosclerotic arteries.
Collapse
|
7
|
AlBadri A, Bairey Merz CN, Johnson BD, Wei J, Mehta PK, Cook-Wiens G, Reis SE, Kelsey SF, Bittner V, Sopko G, Shaw LJ, Pepine CJ, Ahmed B. Impact of Abnormal Coronary Reactivity on Long-Term Clinical Outcomes in Women. J Am Coll Cardiol 2019; 73:684-693. [PMID: 30765035 PMCID: PMC6383781 DOI: 10.1016/j.jacc.2018.11.040] [Citation(s) in RCA: 145] [Impact Index Per Article: 29.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Revised: 10/30/2018] [Accepted: 11/05/2018] [Indexed: 01/15/2023]
Abstract
BACKGROUND Currently as many as one-half of women with suspected myocardial ischemia have no obstructive coronary artery disease (CAD), and abnormal coronary reactivity (CR) is commonly found. OBJECTIVES The authors prospectively investigated CR and longer-term adverse cardiovascular outcomes in women with and with no obstructive CAD in the National Heart, Lung, and Blood Institute-sponsored WISE (Women's Ischemia Syndrome Evaluation) study. METHODS Women (n = 224) with signs and symptoms of ischemia underwent CR testing. Coronary flow reserve and coronary blood flow were obtained to test microvascular function, whereas epicardial CR was tested by coronary dilation response to intracoronary (IC) acetylcholine and IC nitroglycerin. All-cause mortality, major adverse cardiovascular events (MACE) (cardiovascular death, myocardial infarction, stroke, and heart failure), and angina hospitalizations served as clinical outcomes over a median follow-up of 9.7 years. RESULTS The authors identified 129 events during the follow-up period. Low coronary flow reserve was a predictor of increased MACE rate (hazard ratio [HR]: 1.06; 95% confidence interval [CI]: 1.01 to 1.12; p = 0.021), whereas low coronary blood flow was associated with increased risk of mortality (HR: 1.12; 95% CI: 1.01 to 1.24; p = 0.038) and MACE (HR: 1.11; 95% CI: 1.03 to 1.20; p = 0.006) after adjusting for cardiovascular risk factors. In addition, a decrease in cross-sectional area in response to IC acetylcholine was associated with higher hazard of angina hospitalization (HR: 1.05; 95% CI: 1.02 to 1.07; p < 0.0001). There was no association between epicardial IC-nitroglycerin dilation and outcomes. CONCLUSIONS On longer-term follow-up, impaired microvascular function predicts adverse cardiovascular outcomes in women with signs and symptoms of ischemia. Evaluation of CR abnormality can identify those at higher risk of adverse outcomes in the absence of significant CAD. (Women's Ischemia Syndrome Evaluation [WISE]; NCT00000554).
Collapse
Affiliation(s)
- Ahmed AlBadri
- Division of Cardiology, Department of Medicine, Emory University School of Medicine, Atlanta, Georgia
| | - C Noel Bairey Merz
- Barbra Streisand Women's Heart Center, Cedars-Sinai Heart Institute, Los Angeles, California.
| | - B Delia Johnson
- Cardiovascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Janet Wei
- Barbra Streisand Women's Heart Center, Cedars-Sinai Heart Institute, Los Angeles, California
| | - Puja K Mehta
- Division of Cardiology, Department of Medicine, Emory University School of Medicine, Atlanta, Georgia
| | - Galen Cook-Wiens
- Biostatistics and Bioinformatics Research Center, Cedars-Sinai Medical Center, Los Angeles, California
| | - Steven E Reis
- Cardiovascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Sheryl F Kelsey
- Cardiovascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Vera Bittner
- Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
| | - George Sopko
- Division of Cardiovascular Sciences, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Leslee J Shaw
- Division of Cardiology, Department of Medicine, Emory University School of Medicine, Atlanta, Georgia
| | - Carl J Pepine
- Division of Cardiovascular Medicine, University of Florida College of Medicine, Gainesville, Florida
| | - Bina Ahmed
- Division of Cardiovascular Disease, Department of Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
| |
Collapse
|
8
|
Ciampi Q, Cortigiani L, Pratali L, Rigo F, Villari B, Picano E, Sicari R. Left Bundle Branch Block Negatively Affects Coronary Flow Velocity Reserve and Myocardial Contractile Reserve in Nonischemic Dilated Cardiomyopathy. J Am Soc Echocardiogr 2015; 29:112-8. [PMID: 26365426 DOI: 10.1016/j.echo.2015.08.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2015] [Indexed: 01/19/2023]
Abstract
BACKGROUND Coronary flow velocity reserve (CFVR) of the left anterior descending coronary artery (LAD) and myocardial contractile reserve are often impaired in nonischemic dilated cardiomyopathy (DCM). Whether they are affected by the presence of left bundle branch block (LBBB) remains unaddressed. The aim of the study was to investigate how LBBB influences CFVR of the LAD and myocardial contractile reserve in patients with DCM. METHODS One hundred eighty-one patients with DCM (116 men; mean age, 63 ± 12 years) underwent high-dose dipyridamole (0.84 mg/kg over 6 min) stress echocardiography with CFVR evaluation of the LAD by Doppler. All patients had ejection fractions < 40% (mean, 31 ± 8%) and angiographically normal or near normal coronary arteries. CFVR was defined as the ratio between hyperemic peak and basal peak diastolic coronary flow velocities. CFVR > 2.0 was considered normal. Inotropic reserve was defined as rest-stress variation in wall motion score index ≥ 0.20. This was a prospective analysis of an unselected sample consecutively enrolled and retrospectively selected. RESULTS The study group was separated on the basis of presence (n = 122) or absence (n = 59) of LBBB. Patients with LBBB were older (64 ± 11 vs 59 ± 12 years, P = .004) and had reduced resting ejection fractions (30 ± 9% vs 33 ± 7%, P = .02), CFVR of the LAD (1.96 ± 0.41 vs 2.23 ± 0.73, P = .001), and myocardial contractile reserve (variation in wall motion score index, -0.18 ± 0.17 vs -0.33 ± 0.28; P < .001). On multivariate logistic regression analysis, resting ejection fraction (hazard ratio [HR], 1.15; 95% CI, 1.03-1.29; P = .01), smoking habit (HR, 2.63; 95% CI, 1.23-5.62; P = .01), and LBBB (HR, 2.29; 95% CI, 1.05-5.04; P = .04) were independently associated with reduced CFVR, while restrictive transmitral pattern (HR, 2.56; 95% CI, 1.18-5.55; P = .02), end-diastolic volume (HR, 0.98; 95% CI, 0.67-0.99; P = .02), and LBBB (HR, 2.20; 95% CI, 1.11-4.34; P = .02) independently predicted reduced myocardial contractile reserve. CONCLUSIONS CFVR during vasodilator stress echocardiography is a suitable tool for assessing microvascular dysfunction in routine clinical practice. Patients with DCM and LBBB show more severe forms of microvascular dysfunction, which is related to worse left ventricular function and lack of contractile reserve. Therapeutic interventions to restore microvascular function may improve left ventricular function parameters in patients with DCM.
Collapse
Affiliation(s)
- Quirino Ciampi
- Division of Cardiology, Fatebenefratelli Hospital, Benevento, Italy.
| | | | | | - Fausto Rigo
- Department of Cardiology, Dell'Angelo Hospital, Mestre, Italy
| | - Bruno Villari
- Division of Cardiology, Fatebenefratelli Hospital, Benevento, Italy
| | | | - Rosa Sicari
- CNR, Institute of Clinical Physiology, Pisa, Italy
| |
Collapse
|
9
|
Galderisi M, Rigo F, Gherardi S, Cortigiani L, Santoro C, Sicari R, Picano E. The impact of aging and atherosclerotic risk factors on transthoracic coronary flow reserve in subjects with normal coronary angiography. Cardiovasc Ultrasound 2012; 10:20. [PMID: 22583387 PMCID: PMC3403974 DOI: 10.1186/1476-7120-10-20] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2012] [Accepted: 05/14/2012] [Indexed: 11/10/2022] Open
Abstract
Age may affect coronary flow reserve (CFR) especially in subjects with atherosclerotic risk factors (ARFs). The aim of this prospective, multicenter, observational study was to determine the effects of aging on CFR in patients with normal epicardial coronary arteries and ARFs. Three-hundred-thirty-five subjects (mean age = 61 years) with at least one ARF but normal coronary angiography underwent high-dose dipyridamole stress-echo with Doppler evaluation of left anterior descending artery. CFR was calculated as the ratio between hyperemic and resting coronary diastolic peak velocities. Patients were divided in age quartiles. CFR was progressively reduced with aging (1st quartile: 3.01 ± 0.69, 4th quartile: 2.39 ± 0.49, p < 0.001). This was mainly due to a gradual increase of resting velocities (1st quartile = 26.3 ± 6.1 cm/s, 4th quartile = 30.2 ± 6.4 cm/s, p < 0.001) while the reduction of hyperemic velocities remained unaffected (1st quartile = 77.7 ± 18.9 cm/s, 4th quartile = 70.9 ± 18.4 cm/s, NS). When age quartiles and ARFs were entered into a regression model, third and fourth age quartile (p < 0.0005 and p < 0.0001 respectively), left ventricular mass index (p < 0.0001), diastolic blood pressure (p < 0.001), total cholesterol (p < 0.002), fasting blood glucose (p < 0.01) and male gender (p < 0.05) were independent determinants of CFR in the whole population. Aging reduces coronary flow reserve in patients with angiographically normal coronary arteries due to a gradual increase of resting coronary flow velocity. CFR is also affected by atherosclerotic risk factors and left ventricular hypertrophy.
Collapse
Affiliation(s)
- Maurizio Galderisi
- Division of Cardioangiology, Department of Clinical and Experimental Medicine, Federico II University Hospital, Naples, Italy.
| | | | | | | | | | | | | |
Collapse
|
10
|
Effects of type 2 diabetes mellitus on coronary microvascular function and myocardial perfusion in patients without obstructive coronary artery disease. Eur J Nucl Med Mol Imaging 2012; 39:1199-206. [PMID: 22526959 DOI: 10.1007/s00259-012-2117-9] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2011] [Accepted: 03/11/2012] [Indexed: 10/28/2022]
Abstract
PURPOSE We assessed the impact of type 2 diabetes, in the presence of other major cardiovascular risk factors, on coronary microvascular function and myocardial perfusion in patients without obstructive coronary artery disease (CAD). METHODS In this prospective study, 23 patients with type 2 diabetes and 26 nondiabetic patients matched for age, sex and other cardiovascular risk factors underwent a cold pressure test (CPT) and dipyridamole transthoracic echocardiography to determine their coronary flow (CF) ratio. Within 2 weeks, all diabetic patients also underwent dipyridamole-rest myocardial perfusion single-photon emission (MPS) CT. None of the patients with or without diabetes had significant CAD on invasive coronary angiography. RESULTS The CPT-CF ratio was significantly lower in diabetic patients than in nondiabetic patients (1.46 ± 0.26 vs. 1.71 ± 0.32, p = 0.006) and was correlated significantly with fasting glycaemia (r = -0.35, p = 0.01), but not with glycated haemoglobin. The dipyridamole-CF ratio was also lower in diabetic patients than in nondiabetic patients (2.38 ± 0.74 vs. 2.75 ± 0.49, p = 0.04). On MPS imaging, 5 diabetic patients (22%) had stress-induced ischaemia and the remaining 18 (78%) had normal myocardial perfusion. The dipyridamole-CF ratio was not different in patients with and without reversible defects (2.3 ± 1.1 vs. 2.4 ± 0.6, p = 0.97). CONCLUSION Coronary microvascular function is impaired in type 2 diabetic patients without significant CAD, compared to nondiabetic patients with similar other cardiovascular risk factors. In the majority of diabetic patients, microvascular dysfunction is associated with normal myocardial perfusion.
Collapse
|
11
|
Clinical Applications of Transthoracic Doppler Echocardiographic Coronary Flow Reserve Measurements in the Left Anterior Descending Coronary Artery. J Med Ultrasound 2011. [DOI: 10.1016/j.jmu.2011.10.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
12
|
Capaldo B, Galderisi M, Turco AA, D'Errico A, Nosso G, Sidiropulos M, de Divitiis O, Riccardi G. Coronary vasoreactivity is not altered in young people with type 1 diabetes. Nutr Metab Cardiovasc Dis 2010; 20:748-753. [PMID: 20080039 DOI: 10.1016/j.numecd.2009.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2009] [Revised: 06/16/2009] [Accepted: 06/16/2009] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND AIM Abnormal coronary microvascular circulation has been demonstrated in diabetes and is associated with increased rate of cardiovascular events. Our objective was to evaluate coronary vasoreactivity in young people with type 1 diabetes with and without microvascular complications. METHODS AND RESULTS Twenty-five type 1 diabetic patients without microvascular complications (DC-), 23 with microvascular complications (DC+), and 18 control subjects (C) were studied. Coronary vasoreactivity was assessed by means of coronary flow reserve (CFR). Blood flow velocity in the left anterior descending coronary artery was measured at rest and after high-dose dipyridamole using transthoracic color-guided pulsed Doppler echocardiography. CFR was defined as the ratio of hyperaemic to resting diastolic peak flow velocities. The three groups had similar cardiac function parameters, and also systolic and diastolic blood pressure at rest, which remained unchanged during dipyridamole infusion. Resting coronary flow velocity was comparable in C, DC-, and DC+ (p=ns). Dipyridamole infusion produced a threefold increase in coronary diastolic peak velocity, which reached similar values in C (0.69±0.16 m/s), DC- (0.69±0.18 m/s), and DC+ (0.66±0.11 m/s). Mean CFR ratio was similar in C (3.33±0.66), DC- (3.30±0.51), and DC+ (3.24±0.60). At multiple linear regression analysis, no association was found between CFR and age, sex, HbA(1c), duration of diabetes, and complications. CONCLUSION Coronary vasodilatory function is preserved in young D patients, even those with early microvascular complications, suggesting that coronary vasoreactivity deteriorates at more advanced stages of microvascular complications and/or in the presence of other cardiovascular risk factors.
Collapse
Affiliation(s)
- B Capaldo
- Department of Clinical and Experimental Medicine, University Federico II, Naples, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Meimoun P, Malaquin D, Benali T, Boulanger J, Zemir H, Tribouilloy C. Transient impairment of coronary flow reserve in tako-tsubo cardiomyopathy is related to left ventricular systolic parameters. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY 2008; 10:265-70. [PMID: 18755700 DOI: 10.1093/ejechocard/jen222] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
AIMS Recent studies suggest that coronary flow reserve (CFR) is transiently impaired in tako-tsubo cardiomyopathy (TTC). Mechanisms by which such impairment occurs are still unknown. To assess the relationship between CFR obtained by transthoracic Doppler echocardiography (TDE) and parameters of left ventricular (LV) performance in patients with TTC. METHODS AND RESULTS A total of 20 consecutive patients in sinus rhythm, with TTC (mean age 70+/-9 years, 19 women) underwent serial evaluation of TDE-CFR, in the distal part of the left anterior descending coronary artery (LAD), at the acute phase and after recovery using intravenous adenosine infusion (140 microg/kg/min over 2 min). CFR was calculated as hyperaemic to basal mean diastolic coronary flow velocity (CFV). Average of the septal and lateral mitral annulus early diastolic (Ea) and systolic (Sa) tissue velocity, early (E) and late (A) diastolic transmitral velocity, the ratio E/Ea, wall motion score (WMS, 16 segment model), LV end-systolic volume index (ESV/m(2)) and LV end-diastolic volume index (EDV/m(2), biplane-Simpson method) were serially measured by TDE. Basal CFV, LV mass index and haemodynamics parameters did not differ between acute phase and recovery, whereas hyperaemic CFV increased significantly after recovery (P<0.01) leading to a greater CFR (2.9+/-0.3 vs. 2.1+/-0.4, P<0.0001). At the acute phase, hyperaemic CFV was significantly correlated to WMS, ESV/m(2), but not to E/Ea, whereas at recovery, hyperaemic CFV was not correlated to LV parameters. The improvement of CFR was closely correlated to the decrease of ESV/m(2), of WMS, but not to diastolic parameters. No significant correlation was found between CFR and E/Ea or LV mass index at each stage. CONCLUSION There is a transient impairment of CFR at the acute phase of TTC, which is due to a reduced vasodilating capacity. This impairment is closely correlated to LV systolic parameters. Diastolic compressive forces to the coronary microcirculation do not appear to play a critical role.
Collapse
Affiliation(s)
- Patrick Meimoun
- Department of Cardiology and Intensive Care Unit, Compiègne Hospital, 8 rue Henri Adnot, 60200 Compiègne, France.
| | | | | | | | | | | |
Collapse
|
14
|
Galderisi M, D'Errico A. Beta-blockers and coronary flow reserve: the importance of a vasodilatory action. Drugs 2008; 68:579-90. [PMID: 18370439 DOI: 10.2165/00003495-200868050-00002] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Coronary flow reserve (CFR) is the maximal increase in coronary blood flow (CBF) above its resting level for a given perfusion pressure when coronary vasculature is maximally dilated. Normally, hyperaemic CBF reaches values at least 2- to 3-fold greater than resting CBF. Reduction of CFR is mainly due to epicardial coronary artery stenosis or to coronary microvascular dysfunction. CFR can be determined by several techniques that measure CBF itself (e.g. positron emission tomography) or CBF velocities (Doppler methods) from which coronary flow velocity reserve is calculated. Hyperaemic coronary vasodilation can be obtained by pharmacological agents (e.g. adenosine and dipyridamole), but also by the cold pressure test. Long-term antihypertensive treatment induces significant improvement of CFR, which is parallel to the regression of left ventricular (LV) hypertrophy. First- and second-generation beta-adrenergic receptor antagonists (beta-blockers) have shown contradictory influences on CFR. This can be explained by the interaction of the effects on CBF at rest, generally reduced by these drugs, and after hyperaemia, when minimal coronary resistance appears to be either increased or reduced. Third-generation beta-blockers (e.g. carvedilol and nebivolol), which have vasodilating capacity, improve hyperaemic CBF. This occurs as a result of a reduction in minimal resistance, which can be attributed to alpha-adrenergic blockade and/or to a nitric oxide-mediated effect. This improvement is clearly beneficial in patients with coronary artery disease and indicates an improved coronary microvascular function. Changes of CFR due to vasodilating beta-blockers improve microvascular angina pectoris or silent ischaemia in patients without epicardial artery stenosis, and are also helpful in predicting the response or the further improvement of LV function to treatment.
Collapse
Affiliation(s)
- Maurizio Galderisi
- Cardioangiology Unit with CCU, Department of Clinical and Experimental Medicine, Federico II University Hospital, Naples, Italy.
| | | |
Collapse
|
15
|
Kolyva C, Spaan JAE, Piek JJ, Siebes M. Windkesselness of coronary arteries hampers assessment of human coronary wave speed by single-point technique. Am J Physiol Heart Circ Physiol 2008; 295:H482-90. [PMID: 18515650 DOI: 10.1152/ajpheart.00223.2008] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A novel single-point technique to calculate local arterial wave speed (SPc) has recently been presented and applied in healthy human coronary arteries at baseline flow. We investigated its applicability for conditions commonly encountered in the catheterization laboratory. Intracoronary pressure (P(d)) and Doppler velocity (U) were recorded in 29 patients at rest and during adenosine-induced hyperemia in a distal segment of a normal reference vessel and downstream of a single stenosis before and after revascularization. Conduit vessel tone was minimized with nitroglycerin. Microvascular resistance (MR) and SPc were calculated from P(d) and U. In the reference vessel, SPc decreased from 21.5 m/s (SD 8.0) to 10.5 m/s (SD 4.1) after microvascular dilation (P < 0.0001). SPc was substantially higher in the presence of a proximal stenosis and decreased from 34.4 m/s (SD 18.2) at rest to 27.5 m/s (SD 13.4) during hyperemia (P < 0.0001), with a concomitant reduction in P(d) by 20 mmHg and MR by 55.4%. The stent placement further reduced hyperemic MR by 26% and increased P(d) by 26 mmHg but paradoxically decreased SPc to 13.1 m/s (SD 7.7) (P < 0.0001). Changes in SPc correlated strongly with changes in MR (P < 0.001) but were inversely related to changes in P(d) (P < 0.01). In conclusion, the single-point method yielded erroneous predictions of changes in coronary wave speed induced by a proximal stenosis and distal vasodilation and is therefore not appropriate for estimating local wave speed in coronary vessels. Our findings are well described by a lumped reservoir model reflecting the "windkesselness" of the coronary arteries.
Collapse
Affiliation(s)
- Christina Kolyva
- Dept. of Medical Physics, Academic Medical Ctr., Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
| | | | | | | |
Collapse
|
16
|
Maret E, Engvall J, Nylander E, Ohlsson J. Feasibility and diagnostic power of transthoracic coronary Doppler for coronary flow velocity reserve in patients referred for myocardial perfusion imaging. Cardiovasc Ultrasound 2008; 6:12. [PMID: 18373873 PMCID: PMC2292686 DOI: 10.1186/1476-7120-6-12] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2008] [Accepted: 03/29/2008] [Indexed: 11/12/2022] Open
Abstract
Background Myocardial perfusion imaging (MPI), using single photon emission computed tomography (SPECT) is a validated method for detecting coronary artery disease. Transthoracic Doppler echocardiography (TTDE) of flow at rest and during adenosine provocation has previously been evaluated in selected patient groups. We therefore wanted to compare the diagnostic ability of TTDE in the left anterior descending coronary artery (LAD) to that of MPI in an unselected population of patients with chest pain referred for MPI. Our hypothesis was that TTDE with high accuracy would identify healthy individuals and exclude them from the need for further studies, enabling invasive investigations to be reserved for patients with a high probability of disease. Methods Sixty-nine patients, 44 men and 25 women, age 61 ± 10 years (range 35–82), with a clinical suspicion of stress induced myocardial ischemia, were investigated. TTDE was performed at rest and during adenosine stress for myocardial scintigraphy. Results We found that coronary flow velocity reserve (CFVR) determined from diastolic measurements separated normal from abnormal MPI findings with statistical significance. TTDE identified coronary artery disease, defined from MPI, as reversible ischemia and/or permanent defect, with a sensitivity of 60% and a specificity of 79%. The positive predictive value was 43% and the negative predictive value was 88%. There was an overlap between groups which could be due to abnormal endothelial function in patients with normal myocardial perfusion having either hypertension or diabetes. Conclusion TTDE is an attractive non-invasive method to evaluate chest pain without the use of isotopes, but the diagnostic power is strongly dependent on the population investigated. Even in our heterogeneous clinical cardiac population, we found that CFVR>2 in the LAD excluded significant coronary artery disease detected by MPI.
Collapse
Affiliation(s)
- Eva Maret
- Department of Clinical Physiology, Ryhov County Hospital, SE-551 85 Jonkoping, Sweden.
| | | | | | | |
Collapse
|
17
|
Meimoun P, Tribouilloy C. Non-invasive assessment of coronary flow and coronary flow reserve by transthoracic Doppler echocardiography: a magic tool for the real world. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY 2008; 9:449-57. [PMID: 18296409 DOI: 10.1093/ejechocard/jen004] [Citation(s) in RCA: 89] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Transthoracic Doppler echocardiography, introduced in the echo-lab in recent last years, to measure coronary flow and coronary flow reserve, is a very attractive tool, totally non-invasive, and easily available at bedside. This review summarizes the actual possibilities of this tool, its multiple potential clinical applications and diagnostic insights, and its arising prognosis value, in coronary artery disease as in various settings affecting the coronary microcirculation.
Collapse
Affiliation(s)
- Patrick Meimoun
- Department of Cardiology and Intensive Care Unit, Compiègne Hospital, 8 rue Henri Adnot, 60200 Compiègne, France
| | | |
Collapse
|
18
|
Preserved coronary endothelial function by inhibition of delta protein kinase C in a porcine acute myocardial infarction model. Int J Cardiol 2008; 133:256-9. [PMID: 18242734 DOI: 10.1016/j.ijcard.2007.11.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2007] [Accepted: 11/17/2007] [Indexed: 11/20/2022]
Abstract
BACKGROUND Previous studies demonstrate impairment of endothelial-dependent vasodilation after ischemia/reperfusion (I/R). Though we have demonstrated that inhibition of delta protein kinase C (delta PKC) at reperfusion reduces myocyte damage and improves cardiac function in a porcine acute myocardial infarction (AMI) model, impact of the selective delta PKC inhibitor on epicardial coronary endothelial function remains unknown. METHODS Either delta PKC inhibitor (delta V1-1, n=5) or saline (n=5) was infused into the left anterior descending artery at the last 1 min of the 30-min ischemia by balloon occlusion. In vivo responses to bradykinin (endothelium-dependent vasodilator) or nitroglycerin (endothelium-independent vasodilator) were analyzed at 24 h after I/R using intravascular ultrasound. Vascular responses were calculated as the ratio of vessel area at each time point (30, 60, 90 and 120 s after the infusion), divided by values at baseline (before the infusion). RESULTS In control pigs, endothelial-dependent vasodilation following bradykinin infusion in infarct-related epicardial coronary artery was impaired, whereas in delta PKC inhibitor-treated pigs the endothelial-dependent vasodilation was preserved. Nitroglycerin infusion caused similar vasodilatory responses in the both groups. CONCLUSIONS This is the first demonstration that a delta PKC inhibitor preserves vasodilator capacity in epicardial coronary arteries in an in vivo porcine AMI model. Because endothelial dysfunction correlates with worse outcome in patients with AMI, this preserved endothelial function in epicardial coronary arteries might result in a better clinical outcome.
Collapse
|
19
|
Meimoun P, Malaquin D, Sayah S, Benali T, Luycx-Bore A, Levy F, Zemir H, Tribouilloy C. The coronary flow reserve is transiently impaired in tako-tsubo cardiomyopathy: a prospective study using serial Doppler transthoracic echocardiography. J Am Soc Echocardiogr 2007; 21:72-7. [PMID: 17628401 DOI: 10.1016/j.echo.2007.05.024] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2007] [Indexed: 01/09/2023]
Abstract
The clinical features of tako-tsubo cardiomyopathy or transient left apical ballooning syndrome (LABS) have been clearly described, but the mechanisms are still unknown. Our objective was to prospectively assess coronary microcirculation at the acute phase of LABS and after functional recovery, using Doppler transthoracic echocardiography-coronary flow reserve (CFR). Twelve consecutive patients (11 women, mean age 68 +/- 10 years) satisfying the criteria for LABS underwent Doppler transthoracic echocardiography-CFR in the distal part of the left anterior descending coronary artery, using intravenous adenosine infusion (0.14 mg/kg/min over 2 minutes) at the acute phase and 25 +/- 3 days later. CFR was calculated as the ratio of hyperemic to basal mean diastolic flow velocity. Wall-motion score (WMS) was calculated using the 16-segment model during the same echocardiographic examination (normal WMS = 16). Doppler transthoracic echocardiography-CFR increased between the two examinations from 2.2 +/- 0.4 at the acute phase to 2.9 +/- 0.3 (P < .01), whereas WMS decreased (from 31 +/- 6 at the acute phase to 16.5 +/- 0.8, delta WMS = -14.6 +/- 6, P < .01). All patients exhibited an increase of CFR between the two tests (delta CFR = 0.73 +/- 0.39, range: 0.3-1.6). A significant correlation was observed between delta CFR and delta WMS (r = -0.89, P < .01). In conclusion, serial noninvasive CFR measurements performed in LABS suggested transient microcirculatory impairment during the acute phase of the syndrome. The wall-motion improvement parallel to the dynamic improvement of the microcirculation suggests a role of coronary microcirculatory damage in the pathogenesis of acute and transient wall-motion abnormalities in LABS.
Collapse
Affiliation(s)
- Patrick Meimoun
- Department of Cardiology and Intensive Care Unit, Compiègne Hospital, Compiègne, France.
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Lee TM, Su SF, Tsai CH. Effects of distension of urinary bladder on coronary conduit and resistance vessels in hyperlipidemic patients. Clin Cardiol 2006; 25:467-73. [PMID: 12375805 PMCID: PMC6654040 DOI: 10.1002/clc.4960251006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Distension of the urinary bladder reflexly causes a change of coronary vasomotor response. The effect of such distension on the coronary circulation in hyperlipidemic patients, a condition with impaired endothelial function, remains unknown. HYPOTHESIS We tested the hypothesis whether urinary bladder distension caused an exaggerated vasomotor response of epicardial and resistance vasoconstriction in hyperlipidemic patients. METHODS Thirty patients with early atherosclerosis (< 50% diameter stenosis) were divided into three groups: Group 1 (n = 10): hyperlipidemia without doxazosin administration; Group 2 (n = 10): hyperlipidemia with pretreatment of alpha1-adrenergic receptor blocker (oral doxazosin 2 mg); and Group 3 (n = 10): normolipidemia. A prospective analysis of the results of quantitative angiograms, intracoronary Doppler flow, and lactate concentrations from aortic root and coronary sinus was performed during distension of urinary bladder. RESULTS Bladder distension significantly decreased coronary diameter at the stenotic segments (p = 0.004), coronary blood flow (p = 0.05), and increased coronary resistance (p = 0.006) compared with baseline values, in Group 1 patients. In Group 2 patients during bladder distension, coronary diameter, coronary blood flow, and coronary resistance showed no significant changes compared with baseline values. There were significant differences of stenotic coronary diameter (p = 0.01) between Groups 1 and 3 during bladder distension despite similar changes in rate-pressure product. No significant differences were noted among the groups in the responses of coronary diameter, coronary blood flow, and coronary resistance after nitroglycerin administration. CONCLUSIONS The present study showed that urinary bladder distension caused an abnormal vasomotor response of epicardial vasoconstriction and that a concomitant increased coronary resistance involved mechanisms related to alpha1-adrenoceptors. Hyperlipidemia may further impair the response. Pretreated administration of doxazosin had reversed the changes toward baseline. Vasoconstriction during bladder distension can be relieved after nitroglycerin administration, suggesting an unchanged responsiveness of vascular smooth muscle cells to such distension.
Collapse
Affiliation(s)
- Tsung-Ming Lee
- National Taiwan University College of Medicine, Department of Internal Medicine, and National Taiwan University Hospital, Taipei.
| | | | | |
Collapse
|
21
|
Takagi A, Tsurumi Y, Ishizuka N, Omori H, Arai K, Hagiwara N, Kasanuki H. Single administration of cerivastatin, an HMG-CoA reductase inhibitor, improves the coronary flow velocity reserve: a transthoracic Doppler echocardiography study. Heart Vessels 2006; 21:298-301. [PMID: 17151817 DOI: 10.1007/s00380-006-0905-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2005] [Accepted: 01/13/2006] [Indexed: 10/23/2022]
Abstract
HMG-CoA reductase inhibitors (statins) have been shown to improve the endothelial function by lowering lipids. Recent studies also suggest a direct impact of statins on the vascular wall. We assessed the rapid effect of cerivastatin on the coronary flow velocity reserve (CFVR) using transthoracic Doppler echocardiography (TTDE). The coronary flow velocity from the distal left anterior descending artery was measured in 16 healthy subjects (all male, age 24-38 years) using a 5-MHz transducer, on the day before, just before, and 3 h after administering 0.3 mg of cerivastatin. Hyperemia was achieved by the intravenous administration of adenosine, and the CFVR was calculated as the radio of the mean diastolic hyperemic coronary flow velocity to the basal flow velocity. The serum lipid profile and high-sensitivity C-reactive protein (hsCRP) were measured. The CFVR following the single administration of cerivastatin increased from 2.93+/-0.58 to 3.91+/-0.86, P=0.003, and was significantly higher than the CFVR measured at the same time on the previous day (3.91+/-0.86 vs 3.37+/-0.48, P=0.009). Neither the serum lipid profile nor hsCRP exhibited a remarkable change after cerivastatin administration. We concluded that a single-dose administration of cerivastatin, an HMG-CoA reductase inhibitor, improves the coronary flow velocity reserve without modifying the serum lipid profile.
Collapse
Affiliation(s)
- Atsushi Takagi
- Department of Cardiology, Tokyo Women's Medical University Hospital, 8-1 Kawada-cho, Shinjuku, Tokyo, 162-8666, Japan.
| | | | | | | | | | | | | |
Collapse
|
22
|
Rigo F, Gherardi S, Galderisi M, Cortigiani L. Coronary flow reserve evaluation in stress-echocardiography laboratory. J Cardiovasc Med (Hagerstown) 2006; 7:472-9. [PMID: 16801808 DOI: 10.2459/01.jcm.0000234765.58207.b3] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The assessment of coronary flow reserve by transthoracic echocardiography has recently been introduced into clinical practice with good results for the diagnosis of left anterior descending artery disease and fairly promising results for posterior descending coronary artery disease. By looking at what is behind wall motion, we may realize a sonographer's dream and, in particular, the addition of coronary flow reserve to regional wall motion analysis allows us to have - in the same sitting - high specificity (regional wall motion) and a highly sensitive (coronary flow reserve) diagnostic marker, with an improvement in overall diagnostic accuracy. Coronary flow reserve evaluation may shift the balance of stress choice in favor of vasodilators, which are easier to perform with dual imaging than dobutamine or exercise coronary flow reserve evaluation and may shift the choice in favor of dipyridamole or adenosine stress tests, which are also easier to perform with dual imaging than those using dobutamine or exercise. Lastly, it adds quantitative support to the exquisitely qualitative assessment of wall motion analysis, thereby facilitating the communication of stress echo results to the cardiological world outside the echo laboratory.
Collapse
Affiliation(s)
- Fausto Rigo
- Department of Cardiology, Umberto I Hospital, Mestre-Venice, Italy.
| | | | | | | |
Collapse
|
23
|
Hutchison SJ, Browne AEM, Ko E, Chou TM, Zellner C, Komesaroff PA, Chatterjee K, Sudhir K. Dehydroepiandrosterone Sulfate Induces Acute Vasodilation of Porcine Coronary Arteries In Vitro and In Vivo. J Cardiovasc Pharmacol 2005; 46:325-32. [PMID: 16116338 DOI: 10.1097/01.fjc.0000175434.64412.9d] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Although an inverse relationship between dehydroepiandrosterone sulfate (DHEAS) and coronary artery disease has been demonstrated in men, the vascular effects of DHEAS are not well defined. The vasoactive effects of intracoronary DHEAS and testosterone (0.1 nM to 1 microM) were examined in vivo in 24 pigs. Epicardial cross-sectional area was measured by intravascular ultrasound, and coronary flow velocity by intravascular Doppler velocimetry. We also examined the effects of antagonism of the androgen receptor, nitric oxide synthase, and potassium channels on DHEAS-induced vasodilation in vitro in coronary rings from male and female pig hearts. DHEAS and testosterone induced increases in cross-sectional area, average peak velocity, and coronary blood flow. The maximal increase in coronary blood flow in response to testosterone was 1.26-fold (P=0.02), and in average peak velocity 1.43-fold (P=0.05), greater than that to DHEAS, whereas increases in cross-sectional area were similar. Vasodilation to both hormones was rapid, with maximal responses occurring <10 minutes after administration. In vitro, DHEAS and testosterone induced vasodilation in coronary rings, greater with testosterone. At doses of 0.1 and 1 microM, the vasodilator effects of DHEAS and testosterone were inhibited by the androgen receptor antagonist flutamide but not the estrogen receptor antagonist ICI 182,780. At 10 microM, neither DHEAS- nor testosterone-induced vasorelaxation was inhibited by flutamide, ICI 182,780, L-NAME, or deendothelialization, but both were attenuated by pretreatment with glibenclamide. No gender differences were observed in any of the responses examined. In conclusion, DHEAS is an acute coronary artery vasodilator, but less potent than testosterone. Its effect might be mediated via androgen receptors and may involve ATP-sensitive potassium channels.
Collapse
Affiliation(s)
- Stuart J Hutchison
- Vascular Research Laboratory, Division of Cardiology, University of California, San Francisco, California, USA
| | | | | | | | | | | | | | | |
Collapse
|
24
|
Hägg U, Grönros J, Wikström J, Jonsdottir IH, Bergström G, Gan LM. Voluntary physical exercise and coronary flow velocity reserve: a transthoracic colour Doppler echocardiography study in spontaneously hypertensive rats. Clin Sci (Lond) 2005; 109:325-34. [PMID: 15918793 DOI: 10.1042/cs20050052] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In the present study, we have developed and demonstrated a coronary artery imaging protocol in rats using transthoracic high-frequency CDE (colour Doppler echocardiography) to investigate the potential direct effects of exercise on CFVR (coronary flow velocity reserve). SHR (spontaneously hypertensive rats) performed voluntary exercise for 6 weeks. Rats were then submitted to ultrasonographic examination and CFVR measurements. The LAD (left anterior descending coronary artery) was visualized using transthoracic CDE in a modified parasternal long-axis view. Doppler measurement was made in mid-LAD during baseline and adenosine-induced hyperaemic condition. Gene and protein expression in cardiac tissue were studied using real-time PCR and immunohistochemistry. Adenosine infusion significantly (P<0.001, as determined by ANOVA) decreased HR, without affecting blood pressure in anaesthetized SHR. A significantly greater adenosine dose-dependent response was seen in exercised rats compared with controls (P=0.02, as determined by ANOVA). The baseline flow velocity in mid-LAD was 0.33±0.06 and 0.41±0.14 m/s in the exercised and control animals respectively (P value was not significant). The maximum adenosine-induced response was reached at a dose of 140 μg·kg−1 of body weight·min−1, and CFVR averaged at 2.6±0.53 and 1.5±0.24 in exercised and control animals respectively (P<0.01). Gene expression of CuZnSOD was up-regulated by 21% in exercised animals compared with controls (1.1±0.16 compared with 0.89±0.09; P<0.01), whereas eNOS expression was unchanged. In conclusion, CFVR in rats can be non-invasively assessed using CDE with high feasibility. Physical exercise is associated with improved CFVR and antioxidative capacity in SHR.
Collapse
Affiliation(s)
- Ulrika Hägg
- Department of Physiology, Institute of Physiology and Pharmacology, Göteborg University, Göteborg, Sweden
| | | | | | | | | | | |
Collapse
|
25
|
Capaldo B, Galderisi M, Turco AA, D'Errico A, Turco S, Rivellese AA, de Simone G, de Divitiis O, Riccardi G. Acute hyperglycemia does not affect the reactivity of coronary microcirculation in humans. J Clin Endocrinol Metab 2005; 90:3871-6. [PMID: 15797958 DOI: 10.1210/jc.2004-2207] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
OBJECTIVE There is some evidence that acute hyperglycemia (H) may cause vascular dysfunction in normal subjects. This study investigates whether acute, short-term H affects coronary vasodilatory function in healthy subjects. DESIGN Diastolic peak flow velocity in the left anterior descending coronary artery was measured at rest and after dipyridamole (0.56 mg/kg over 4 min) using transthoracic color Doppler echocardiography in 13 healthy men. Coronary flow reserve (CFR) was defined as the ratio of dipyridamole-induced coronary peak diastolic to resting peak diastolic flow velocity. CFR was measured both in euglycemia (E) and after 3 h H ( approximately 14 mmol/liter) by a variable infusion of glucose and octreotide (0.4 mg/h) to prevent increase in insulin concentration. RESULTS Fasting plasma glucose increased to 14.3 +/- 0.33 mmol/liter during the study and maintained variability within less than 10%. Plasma insulin remained nearly stable during H. Resting diastolic flow velocity was 18.5 +/- 0.6 cm/sec in E and increased to 20.0 +/- 0.7 cm/sec during H (P < 0.005). Dipyridamole infusion produced a marked increase in coronary flow velocity, which reached values of 50.8 +/- 2.9 cm/sec in E and 51.8 +/- 2.1 cm/sec in H (P = not significant). CFR was 2.78 +/- 0.16 in E and 2.59 +/- 0.12 in H (P = not significant). CONCLUSION Our study indicates that short-term hyperglycemia does not affect the vasodilatory response of coronary microcirculation in healthy subjects.
Collapse
Affiliation(s)
- Brunella Capaldo
- Department of Clinical and Experimental Medicine, University Federico II, Naples, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Galderisi M, Cicala S, D'Errico A, de Divitiis O, de Simone G. Nebivolol improves coronary flow reserve in hypertensive patients without coronary heart disease. J Hypertens 2004; 22:2201-8. [PMID: 15480106 DOI: 10.1097/00004872-200411000-00024] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To examine the effects of nebivolol, a beta-blocker with nitroxide-mediated vasodilating properties, on coronary flow reserve (CFR) in patients with uncomplicated arterial hypertension. DESIGN, SETTING AND PATIENTS Fourteen newly diagnosed, never-treated, World Health Organization grade I-II hypertensive patients (male/female, 10/4; mean age, 47 years), free of coronary heart disease, underwent standard Doppler echocardiography and determination of CFR in the distal left anterior descending artery by low-dose dipyridamole (0.56 mg/kg intravenously in 4 min) at baseline and after 4 weeks of treatment with 5 mg nebivolol once daily. RESULTS At baseline, nine patients had left ventricular (LV) hypertrophy (LV mass index > or = 51 g/m). After 4 weeks of therapy, the blood pressure was decreased from 148 +/- 8.1/101.4 +/- 4.6 mmHg to 140.7 +/- 7.0/91.1 +/- 7.4 mmHg and end-systolic stress was also significantly reduced. Heart rate was reduced (P <0.01), whereas LV end-diastolic diameter and stroke volume tended to increase (P=0.07 and P=0.09, respectively). No changes were detected in the LV mass index, relative wall thickness, fractional shortening and LV diastolic properties. Both resting and dipyridamole rate-pressure products were lower after nebivolol but dipyridamole-induced changes were not influenced by the therapy. In contrast, nebivolol therapy did not alter coronary velocities at rest, but caused a greater increase in coronary velocities after dipyridamole (P <0.03), leading to a greater CFR (2.12 +/- 0.33 versus 1.89 +/- 0.31, P <0.0001). Nebivolol induced an absolute increase of 8% in the CFR in nine of 14 patients (64.3%). CONCLUSIONS In hypertensive patients free of coronary artery disease, 4-week nebivolol therapy induces a significant increase of the CFR. Nebivolol preserves coronary flow at rest despite the reduction of metabolic (O2 consumption) and hemodynamic (diastolic blood pressure) determinants. The increase of hyperemic coronary velocities appears due to the reduction of coronary resistance.
Collapse
Affiliation(s)
- Maurizio Galderisi
- Cardioangiology Unit, Department of Clinical and Experimental Medicine, Federico II University Hospital, Naples, Italy.
| | | | | | | | | |
Collapse
|
27
|
Andrews RT, Binkert CA. Relative rates of blood flow reduction during transcatheter arterial embolization with tris-acryl gelatin microspheres or polyvinyl alcohol: quantitative comparison in a swine model. J Vasc Interv Radiol 2004; 14:1311-6. [PMID: 14551279 DOI: 10.1097/01.rvi.0000092903.31640.70] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To determine whether two commonly used embolic agents have differing rates of blood flow reduction during transcatheter embolization of the renal arteries in an animal model. MATERIALS AND METHODS The renal arteries of 10 pigs were embolized with either polyvinyl alcohol (300-500 or 500-700- micro m) or tris-acryl gelatin microspheres (300-500 or 700-900- micro m). Equivalent unit doses of each agent were suspended in 40 mL of fluid and injected in 1-mL aliquots for 20 mL and then in 5-mL aliquots for 20 mL. Blood flow was measured after each aliquot with an intraarterial Doppler flow wire placed through the embolization catheter. RESULTS Renal arterial blood flow was most rapidly and reliably decreased by 300-500- and 700-900- micro m microspheres, both of which had achieved >90% reduction from baseline flow after the injection of 6 mL of suspension. An equivalent reduction in flow required 25 mL of 300-500- micro m PVA suspension and 30 mL of 500-700- micro m PVA suspension. The reduction in blood flow with microspheres was significantly greater (P <.05) than that with PVA between 5 and 19 mL of suspension delivered. Differences between larger and smaller particle sizes of the same agent were not statistically significant. CONCLUSIONS Tris-acryl gelatin microspheres reduced renal blood flow more quickly and reliably than did PVA. The type of agent used in embolization had a greater impact on the rate of flow reduction than did particle size in the range of sizes tested.
Collapse
Affiliation(s)
- Robert T Andrews
- Dotter Interventional Institute, University of Washington Medical Center, 1959 NE Pacific St., RR 215, Box 357115, Seattle, Washington 98195-7115, USA.
| | | |
Collapse
|
28
|
Lupotti FA, Mastik F, Carlier SG, de Korte CL, van der Giessen WJ, Serruys PW, van der Steen AFW. Quantitative IVUS blood flow: validation in vitro, in animals and in patients. ULTRASOUND IN MEDICINE & BIOLOGY 2003; 29:507-515. [PMID: 12749921 DOI: 10.1016/s0301-5629(02)00774-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
In recent years, a new method to measure transverse blood flow based on the decorrelation of the radiofrequency (RF) signals of intravascular ultrasound (IVUS) rotating single-element scanners was introduced. We report here in vitro, animal and patient testing to evaluate the correlation-based method using an IVUS array catheter. A new correlation-based method to dynamically correct the correlation coefficients for noise is implemented. The decorrelation due to noise was estimated from the correlation coefficients from flowing blood obtained at increasing time lags. First, blood flow experiments were carried out with different catheters in a tissue-mimicking flow phantom with an inner diameter ranging from 3.0 to 5.0 mm. A calibrated electromagnetic flow meter (EMF, range: 0 to 250 cc/min) was used as a reference. Good linear relationships were found between the IVUS-derived flow and the calibrated EMF (all R(2)> 0.96). The catheter position within the flow phantom and the size of the ring-down were theoretically analyzed. These elements, and noise in the RF signals, have an important influence on the IVUS blood flow measurements reflected by the offset and the slope of the linear relationships. By placing the IVUS catheter outside the flow phantom, parabolic blood flow profiles were also measured. Second, IVUS blood flow measurements were performed in the carotid artery of two Yorkshire pigs, which showed linear relationships (all R(2)> 0.85) between the IVUS-derived flow and the calibrated EMF. Experimentally, the offset was lower than 3 mL/min and the slope was close to 1. Third, IVUS blood flow measurements were performed in coronary arteries in patients. Preliminary results for the coronary flow reserve (CFR = high flow/baseline flow) in patients using the decorrelation method of RF signals of an array IVUS scanner were comparable with CFR based on Doppler measurements.
Collapse
Affiliation(s)
- Fermín A Lupotti
- Interuniversity Cardiology Institute of the Netherlands (I.C.I.N.), Utrecht, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
29
|
Gatzoulis L, Ramnarine KV, Pye SD, Anderson T, Newby DE, Hoskins PR, McDicken WN. Doppler colour flow imaging and flow quantification with a novel forward-viewing intravascular ultrasound system. ULTRASOUND IN MEDICINE & BIOLOGY 2003; 29:53-64. [PMID: 12604117 DOI: 10.1016/s0301-5629(02)00699-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The aim of this work was to investigate the potential of a novel forward-viewing intravascular ultrasound (IVUS) system for flow quantification and colour flow imaging combined with B-mode imaging. A stiff 3.8-mm diameter catheter was used to scan a 72 degrees sector ahead of its tip. Operating at 30 MHz, the catheter was integrated with an IVUS scanner and a radiofrequency (RF) data-acquisition system. RF data were software processed for producing B-mode images and deriving velocity estimates. Steady flow in the range of 45 to 146 mL/min toward the catheter, was used in wall-less tissue-mimicking phantoms simulating healthy lumen (8-mm diameter), 30% diameter symmetrical stenosis and 37% diameter eccentric stenosis. The system provided colour flow images and good estimation of peak velocity and volumetric flows (within 1% to 9% and 16% to 48%, respectively, of calculated values) at 5 to 7 mm distal to the catheter. A sector forward-viewing IVUS imaging/Doppler system is suitable for combined anatomical and functional assessment of stenosed vessels.
Collapse
Affiliation(s)
- Loukianos Gatzoulis
- Department of Medical Physics and Medical Engineering, University of Edinburgh, Edinburgh, UK
| | | | | | | | | | | | | |
Collapse
|
30
|
Fernández del Palacio MJ, Luis Fuentes V, Bonagura JD, Schober KE, Hatfield DG, Laughlin MH. Evaluation of transcutaneous Doppler ultrasonography for the measurement of blood flow in the femoral artery of pigs. Am J Vet Res 2003; 64:43-50. [PMID: 12518877 DOI: 10.2460/ajvr.2003.64.43] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare measurements of blood flow in the common femoral artery obtained by duplex Doppler ultrasonography (DDU) and a reference ultrasonic transit-time flow (TTF) method and to examine the impact of Doppler spectral waveform measurement techniques on volumetric estimates. ANIMALS 5 healthy female pigs. PROCEDURES Femoral arterial blood flow was measured simultaneously in anesthetized pigs by use of a TTF probe (left femoral artery) and transcutaneous DDU (right femoral artery). A range of flow states was induced pharmacologically by using xylazine, bradykinin, dobutamine, and isoflurane. Volumetric blood flow was calculated from DDU waveforms, using the product of the flow velocity integral (FVI), the cross-sectional vessel area, and heart rate. Three calculations of FVI were obtained by manually tracing the Doppler spectral envelopes at the outer envelope, the modal, and the inner envelope of the spectral dispersion pattern. Data analysis included calculation of Pearson correlation coefficients and Bland-Altman limits of agreement. RESULTS Blood flow measured by DDU was more closely correlated with TTF measurements when the modal or inner envelope tracing method was used (r, 0.76 and 0.78; limits of agreement, -100 to 54.2 and -48.5 to 770 mL/min, respectively). Limits of agreement for the outer envelope tracing method were -238.5 to 64 mL/min. CONCLUSIONS AND CLINICAL RELEVANCE Transcutaneous DDU is a reliable noninvasive technique for measuring blood flow in the femoral artery of pigs over a range of flow states. Tracing the inner envelope of the Doppler spectral dispersion pattern provided the best estimate of blood flow in this study.
Collapse
|
31
|
Voci P, Pizzuto F, Mariano E, Puddu PE, Chiavari PA, Romeo F. Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound. Am J Cardiol 2002; 90:988-91. [PMID: 12398967 DOI: 10.1016/s0002-9149(02)02666-8] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
We describe for the first time transthoracic Doppler ultrasound assessment of coronary flow reserve (CFR) in both the posterior descending (PDA) and left anterior descending (LAD) coronary arteries. CFR (hyperemic/resting diastolic flow velocity ratio) was measured by 90-second intravenous adenosine infusion (140 microg/kg/min). Baseline PDA flow was detected in 62 of 81 subjects (76%), and the CFR was measurable in 44 of them (54%) because of adenosine-induced hyperventilation. According to angiography, these 44 subjects were divided into 3 groups: group 1 (0% to 29% stenosis), group 2 (30% to 69% stenosis), and group 3 (> or =70% stenosis). PDA CFR was 2.62 +/- 0.25 in 17 patients in group 1, 2.33 +/- 0.32 in 9 patients in group 2, and 1.40 +/- 0.54 in 18 patients in group 3 (F = 41.83, p <0.0001). LAD CFR was 3.31 +/- 0.54 in 15 patients in group 1, 2.49 +/- 0.71 in 10 patients in group 2, and 1.12 +/- 0.49 in 19 patients in group 3 (F = 65.68, p <0.0001). A cut-off of <2 identified > or =70% stenosis in both of the arteries supplying the PDA and in the LAD. Noninvasive measurement of PDA CFR is feasible and may improve with technologic advancement and the use of selective adenosine receptor agonists, thus preventing hyperventilation.
Collapse
Affiliation(s)
- Paolo Voci
- Section of Cardiology II, University of Rome "La Sapienza", Rome, Italy.
| | | | | | | | | | | |
Collapse
|
32
|
Jiang XJ, O'Rourke MF, Jin WQL, Liu LS, Li CW, Tai PC, Zhang XC, Liu SZ. Quantification of glyceryl trinitrate effect through analysis of the synthesised ascending aortic pressure waveform. Heart 2002; 88:143-8. [PMID: 12117838 PMCID: PMC1767201 DOI: 10.1136/heart.88.2.143] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVE To establish through analysis of the radial pressure pulse waveform the dose dependent effects of glyceryl trinitrate (GTN) on properties of different blood vessels. DESIGN Radial pulse waveform was measured in randomised order before, during a five hour application of a GTN patch delivering 0.104-0.625 mg/h, and for two hours after patch removal. The radial pressure waveform (Millar applanation tonometer) was convolved into an ascending aortic wave using a generalised transfer function (SphygmoCor process) enabling measurement of aortic systolic, diastolic, pulse, mean, and augmented pressure and left ventricular ejection duration in addition to standard brachial cuff pressures. SETTING Fu Wai and Ren Ming hospitals in Beijing, China. PATIENTS 46 recumbent hospitalised patients aged 56 (9) years, awaiting electrophysiological or other diagnostic studies, fasting, and with other treatments suspended. MAJOR OUTCOME MEASURES Conventional brachial pressure measures and data from the synthesised aortic pulse. RESULTS There was no consistent change in heart rate or brachial pressures except for a decrease in systolic and pulse pressures (p < 0.01) at dose > 0.416 mg/h. In contrast, there were substantial and significant (p < 0.0001) decreases in aortic systolic, pulse, and augmented pressures at all doses, mean pressure (p < 0.001) at doses > 0.416 mg/h, and ejection duration (p < 0.001) at doses > 0.208 mg/h. CONCLUSIONS Pulse waveform analysis exposes dose dependent effects of GTN on the aortic waveform, suggesting muscular conduit arterial dilatation with reduced wave reflection at the lowest dose, arteriolar dilatation and decreased peripheral resistance at the highest dose, and venous dilatation at the intermediate dose.
Collapse
Affiliation(s)
- X J Jiang
- Hypertension Division, Fu Wai Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, PR China
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Newby DE, Fox KAA. Invasive assessment of the coronary circulation: intravascular ultrasound and Doppler. Br J Clin Pharmacol 2002; 53:561-75. [PMID: 12047480 PMCID: PMC1874337 DOI: 10.1046/j.1365-2125.2002.01582.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Affiliation(s)
- David E Newby
- Cardiovascular Research, Department of Cardiology, Royal Infirmary, 1 Lauriston Place, Edinburgh EH3 9YW.
| | | |
Collapse
|
34
|
Wellnhofer E, Bocksch W, Hiemann N, Dandel M, Klimek W, Hetzer R, Fleck E. Shear stress and vascular remodeling: study of cardiac allograft coronary artery disease as a model of diffuse atherosclerosis. J Heart Lung Transplant 2002; 21:405-16. [PMID: 11927216 DOI: 10.1016/s1053-2498(01)00374-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND The assessment of remodeling in diffuse atherosclerosis by intravascular ultrasound is hampered by the lack of an appropriate reference segment. Transplant coronary artery disease is an accepted model of diffuse atherosclerosis. Flow-dependent remodeling is regulated by shear stress. Thus, normal levels of shear stress at baseline flow reflect adequate regulation and provide a functional assessment of flow-dependent remodeling. METHODS The approach was evaluated in 91 patients with transplant coronary artery disease and in 9 non-transplanted controls and 16 control transplant recipients. Quantitative coronary angiography, intracoronary ultrasound and intracoronary velocity studies were performed at baseline and after pharmacologic intervention. Calculated shear stress was compared between these groups and a sub-group with coronary angioplasty at follow-up (8 of 60 patients with control angiography after 23 +/- 8 months). The relation of shear stress to flow, diameter, flow/area ratio and endothelial function was analyzed. RESULTS Normal shear stress was found in non-transplanted controls and transplant recipients without coronary artery disease. Patients with coronary angioplasty at follow-up had elevated shear stress and enhanced endothelial dysfunction on the initial investigation. Shear stress was not correlated with flow (r = 0.062, non-significant), but with diameter (r = -0.654), flow/area ratio (r = 0.814) and endothelial dysfunction (r = 0.722). CONCLUSION Calculated local shear stress appears to be useful for the assessment of the adequacy of flow-dependent macrovascular remodeling in diffuse atherosclerosis. Elevated blood flow/area ratio is a potential clinical marker of increased shear stress that reflects inadequate flow-dependent remodeling.
Collapse
Affiliation(s)
- Ernst Wellnhofer
- Departments of Internal Medicine/Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany.
| | | | | | | | | | | | | |
Collapse
|
35
|
Abstract
Noninvasive imaging techniques offer a unique opportunity to study the relation of surrogate markers to the development of atherosclerosis. These noninvasive imaging modalities include: (1) carotid artery, coronary, and aorta imaging; (2) left ventricular echocardiography imaging; (3) electron-beam computed tomography; (4) magnetic resonance imaging; and (5) ankle-brachial index. Because the incidence of coronary artery disease is a function of the development and progression of atherosclerosis, the use of noninvasive surrogate markers of atherosclerosis can aid in the diagnosis of cardiovascular disease through the identification of subclinical disease. Noninvasive imaging techniques provide an approach for identifying high-risk individuals who may benefit from active intervention to prevent clinical disease.
Collapse
Affiliation(s)
- Steven B Feinstein
- Echocardiography Laboratory, Rush-Presbyterian-St. Luke's Medical Center, Chicago, Illinois 60612, USA.
| | | | | |
Collapse
|
36
|
Tanedo JS, Kelly RF, Marquez M, Burns DE, Klein LW, Costanzo MR, Parrillo JE, Hollenberg SM. Assessing coronary blood flow dynamics with the TIMI frame count method: comparison with simultaneous intracoronary Doppler and ultrasound. Catheter Cardiovasc Interv 2001; 53:459-63. [PMID: 11514994 DOI: 10.1002/ccd.1203] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This study compared the TIMI frame count (TFC), which has been proposed as a method for quantifying coronary blood flow, with coronary flow and microvascular function measured with intracoronary Doppler and intracoronary ultrasound. Coronary blood flow volume was calculated from coronary blood velocity (by intracoronary Doppler) and lumen area (by intracoronary ultrasound) in the LAD in 46 post-heart transplant patients at baseline and after intracoronary adenosine. TFC correlated significantly with average peak coronary blood velocity (r = -0.42; P = 0.004) and coronary lumen area (r = 0.39; P = 0.008), but not with coronary blood flow volume (r = -0.01; P = 0.96) or the coronary flow reserve response to adenosine (r = 0.09; P = 0.58). In conclusion, TFC is a simple method of assessing coronary blood velocity but not volumetric flow. While TFC does not predict coronary flow reserve, as a measure of velocity it does provide an assessment of basal microvascular tone, information that is complementary to that afforded by flow reserve measurements.
Collapse
Affiliation(s)
- J S Tanedo
- Division of Cardiology, Cook County Hospital, Chicago, Illinois, USA
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Tamborini G, Maltagliati A, Trupiano L, Berna G, Sisillo E, Salvi L, Pepi M. Lowering of blood pressure and coronary blood flow in isolated systolic hypertension. Coron Artery Dis 2001; 12:259-65. [PMID: 11428534 DOI: 10.1097/00019501-200106000-00001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND In essential hypertension, the lower limit of autoregulation of coronary flow shifts to higher perfusion and the hypertensive ventricle is at a higher than normal risk of ischemia, and less able to tolerate acute reduction of coronary perfusion pressure. Little is known about pattern of coronary flow in isolated systolic hypertension, a pathologic condition in which the elevated systolic blood pressure is associated with a lower than normal vascular compliance and normal or slightly greater than normal mean arterial pressure and vascular resistance. OBJECTIVE To evaluate the effects of rapid normalization of blood pressure on coronary blood flow in isolated systolic hypertension. METHODS We subjected 20 patients with isolated systolic hypertension to intraoperative hemodynamic and transesophageal echocardiographic monitoring during peripheral vascular surgery. Coronary flow velocity integrals and diameters in the left anterior descending coronary artery were evaluated under baseline conditions and after normalization of blood pressure, which occurred spontaneously during anesthesia (10 cases; group 1A) or was induced by infusion of nitrate (10 cases, group 1B). RESULTS After normalization of systolic blood pressure integrals decreased significantly only for patients in group 1A; percentage changes of diameter were significantly greater for patients in group 1B. Therefore, coronary blood flow after normalization of systolic blood pressure increased for patients in group 1B (by 28+/-25%) and decreased for patients in group 1A (by 30+/-21%). Changes in integrals were inversely related to those in diameter (r= -0.72, P < 0.001); for patients in group 1A changes in coronary perfusion pressure and diameter were related to those of integrals (r= 0.94; P < 0.0005). CONCLUSIONS In isolated systolic hypertension, despite there being similar changes of the systolic blood pressure, administration of nitrates caused a marked increase of coronary flow through direct effects on coronary circulation, whereas spontaneous normotension was associated with a significant reduction of coronary flow.
Collapse
Affiliation(s)
- G Tamborini
- Centro Cardiologico, Fondazione Monzino, IRCCS, Centro di Studio per le Ricerche Cardiovascolari del CNR, Milan, Italy.
| | | | | | | | | | | | | |
Collapse
|
38
|
Kawabata T, Fujii T, Hiro T, Yasumoto K, Yamada J, Yano M, Miura T, Matsuzaki M. Vasodilator responses of coronary conduit and resistance arteries to continuous nitroglycerin infusion in humans: a Doppler guide wire study. J Cardiovasc Pharmacol 2000; 36:764-9. [PMID: 11117377 DOI: 10.1097/00005344-200012000-00012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
To examine the responses of coronary conduit and resistance arteries to the continuous i.v. administration of nitroglycerin in 15 patients with atypical chest pain, we measured coronary blood flow velocity in the left anterior descending coronary artery using a Doppler guide wire and the lumen diameter and cross-sectional area by quantitative coronary angiography. Systolic flow, diastolic flow, total coronary flow, and coronary vascular resistance were calculated. Stepwise increases in dose of nitroglycerin resulted in significant dose-dependent decrease in mean aortic pressure (p < 0.01) and increase in lumen diameter (p < 0.05). After nitroglycerin administration of 0.5 microg/kg/min, systolic flow decreased significantly by 89.9+/-15.7% (p < 0.01), and diastolic flow increased significantly by 74.2+/-37.1% (p < 0.05). Total coronary flow did not change significantly with the various doses of nitroglycerin. However, coronary vascular resistance decreased significantly at concentrations greater than 0.5 microg/kg/min nitroglycerin. Continuous nitroglycerin infusion did not reduce either diastolic or total coronary blood flow despite a significant reduction in coronary perfusion pressure. These results indicate that subendocardial blood flow might be maintained during continuous i.v. infusion of nitroglycerin within the clinical dose range.
Collapse
Affiliation(s)
- T Kawabata
- The Second Department of Internal Medicine, Yamaguchi University School of Medicine, Ube, Japan
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Mikhail MS, Thangathurai D, Thaker KB, Hutchison SJ, Black DR, Chandraratna PA. Echocardiographic assessment of coronary blood flow velocity during controlled hypotensive anesthesia with nitroglycerin. J Cardiothorac Vasc Anesth 2000; 14:565-70. [PMID: 11052440 DOI: 10.1053/jcan.2000.9446] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To determine the effect of nitroglycerin on coronary blood flow velocity during controlled hypotensive anesthesia in humans. DESIGN Internally controlled prospective study. SETTING Single university hospital. PARTICIPANTS Twenty American Society of Anesthesiologists class I and II patients undergoing general anesthesia for surgical resection of a malignancy. INTERVENTIONS General anesthesia was induced with thiopental, fentanyl, and succinylcholine and maintained with isoflurane and vecuronium. Transesophageal echocardiography was used to evaluate left ventricular wall motion and blood flow velocity in the left anterior descending coronary artery. Intravenous nitroglycerin was used to reduce systolic arterial pressure to 60 to 70 mmHg. Intravenous albumin 5% was administered to maintain pulmonary capillary wedge pressure >5 mmHg. MEASUREMENTS AND MAIN RESULTS The left anterior descending coronary artery was visualized clearly in 16 of 20 patients. At a mean nitroglycerin dose of 16+/-14 microg/kg/min, peak diastolic left anterior descending flow velocity increased significantly from 32.5+/-10.3 cm/sec to 44.7+/-14.6 cm/sec (p = 0.0103). None of the patients developed any ST-segment changes. CONCLUSIONS During nitroglycerin-induced hypotensive anesthesia, coronary blood flow as assessed by peak diastolic left anterior descending flow velocity is preserved or increased in most patients. Increases in left anterior descending flow velocity are predictably achieved only at nitroglycerin doses >5 microg/kg/min. Intraoperative transesophageal echocardiography is useful in monitoring coronary flow velocity responses to controlled hypotensive anesthesia.
Collapse
Affiliation(s)
- M S Mikhail
- Department of Anesthesiology, University of Southern California School of Medicine, Kenneth Norris Hospital, Los Angeles 90033, USA
| | | | | | | | | | | |
Collapse
|
40
|
Hildick-Smith DJ, Johnson PJ, Wisbey CR, Winter EM, Shapiro LM. Coronary flow reserve is supranormal in endurance athletes: an adenosine transthoracic echocardiographic study. Heart 2000; 84:383-9. [PMID: 10995406 PMCID: PMC1729440 DOI: 10.1136/heart.84.4.383] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
OBJECTIVE To compare coronary flow reserve in endurance athletes and healthy sedentary controls, using adenosine transthoracic echocardiography. METHODS 29 male endurance athletes (mean (SD) age 27.3 (6.6) years, body mass index (BMI) 22.1 (1.9) kg/m(2)) and 23 male controls (age 27.2 (6.1) years, BMI 23.9 (2.6) kg/m(2)) with no coronary risk factors underwent transthoracic echocardiographic assessment of distal left anterior descending coronary artery (LAD) diameter and flow, both at rest and during intravenous adenosine infusion (140 microg/kg/min). RESULTS Distal LAD diameter and flow were adequately assessed in 19 controls (83%) and 26 athletes (90%). Distal LAD diameter in athletes (2.04 (0.25) mm) was not significantly greater than in sedentary controls (1.97 (0.27) mm). Per cent increase in LAD diameter following 400 microg sublingual nitrate was greater in the athletes than in the controls, at 14.1 (7. 2)% v 8.8 (5.7)% (p < 0.01). Left ventricular mass index in athletes exceeded that of controls, at 130 (19) v 98 (14) g/m(2) (p < 0.01). Resting flow among the athletes (10.6 (3.1) ml/min; 4.4 (1.2) ml/min/100 g left ventricular mass) was less than in the controls (14.3 (3.6) ml/min; 8.2 (2.2) ml/min/100 g left ventricular mass) (both p < 0.01). Hyperaemic flow among the athletes (61.9 (17.8) ml/min) exceeded that of the controls (51.1 (14.6) ml/min; p = 0.02), but not when corrected for left ventricular mass (25.9 (5.6) v 28.5 (7.4) ml/min/100 g left ventricular mass; NS). Coronary flow reserve was therefore substantially greater in the athletes than in the controls, at 5.9 (1.0) v 3.7 (0.7) (p < 0.01). CONCLUSIONS Coronary flow reserve in endurance athletes is supranormal and endothelium independent vasodilatation is enhanced. Myocardial hypertrophy per se does not necessarily impair coronary flow reserve. Adenosine transthoracic echocardiography is a promising technique for the investigation of coronary flow reserve.
Collapse
|
41
|
Lee TM, Su SF, Chen MF, Tsai CH. Acute effects of urinary bladder distention on the coronary circulation in patients with early atherosclerosis. J Am Coll Cardiol 2000; 36:453-60. [PMID: 10933357 DOI: 10.1016/s0735-1097(00)00751-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVES We sought to examine whether distention of the urinary bladder, a physiologic stimulus, could induce impaired coronary circulation in patients with early atherosclerosis. BACKGROUND Distention of the urinary bladder reflexively causes an increase in sympathetic activity. The effect of such distention on the coronary circulation in patients with early atherosclerosis remains unknown. METHODS To assess the effect of bladder distention on coronary dynamic forces, epicardial and microvascular responses were measured with an intracoronary Doppler flow wire in 40 patients with early atherosclerosis (<50% diameter stenosis). Patients were randomized into two groups according to whether they did not (group 1, n = 20) or did have (group 2, n = 20) pretreatment with an alpha1-adrenergic receptor blocker (oral doxazosin, 2 mg). Coronary flow velocity was monitored by quantitative coronary angiography at baseline, during urinary bladder distention and after intracoronary nitroglycerin injection. RESULTS Bladder distention significantly decreased the coronary diameter in the stenotic segments (p<0.001), decreased coronary blood flow (p<0.001) and increased coronary resistance (p<0.001), as compared with baseline values, in group 1 patients. In group 2 patients with bladder distention, the angiographic variables did not show significant changes, as compared with baseline values. No significant differences were noted between the groups in the responses of the angiographic variables after nitroglycerin administration. CONCLUSIONS The present study shows, for the first time, that urinary bladder distention caused vasoconstriction of coronary conduit and resistance vessels involved mechanisms related to alpha1 adrenoceptors. Pretreated administration of doxazosin reversed the changes toward baseline. Vasoconstriction during bladder distention can be relieved after nitroglycerin administration, suggesting an unchanged responsiveness of vascular smooth muscle cells to such distention.
Collapse
Affiliation(s)
- T M Lee
- Department of Internal Medicine, National Taiwan University Hospital, Taipei
| | | | | | | |
Collapse
|
42
|
Schlaifer JD, Mills RM. Effect of low molecular weight heparin on coronary endothelial function in acute cellular heart transplant rejection. Am J Cardiol 2000; 86:117-20. [PMID: 10867109 DOI: 10.1016/s0002-9149(00)00843-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- J D Schlaifer
- University of Florida College of Medicine, Division of Cardiovascular Medicine, Gainesville, Florida, USA
| | | |
Collapse
|
43
|
|
44
|
Jenni R, Linka A, Barton M. Assessment of coronary flow reserve by contrast-enhanced second harmonic echo Doppler. Circulation 2000; 101:E100. [PMID: 10715278 DOI: 10.1161/01.cir.101.10.e100] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
45
|
Nakamoto A, Yoshitake J, Hase T, Harasawa H, Okamoto S, Fuse D, Kawasaki R, Kuga H, Kishiro I, Machida S, Oshiro H, Totsuka M, Kaneko N. Intravascular ultrasound imaging of the pulmonary arteries in primary pulmonary hypertension. Respirology 2000; 5:71-8. [PMID: 10728735 DOI: 10.1046/j.1440-1843.2000.00229.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE Intravascular ultrasound has the unique ability to provide cross-sectional images of the arterial wall. This study examined intravascular ultrasound (IVUS) images of the proximal pulmonary arteries in primary pulmonary hypertension (PPH). METHODOLOGY Study 1: Specimens from four patients who had died of PPH (in vitro PPH group) were compared with those of three patients who had died of subarachnoid haemorrhage but had no evidence of cardiopulmonary disease (in vitro control group). Three-centimetre segments of the following levels were examined by IVUS: pulmonary trunk, eight secondary branch arteries of the upper, middle, and lower lobes of both lungs, and the thoracic descending aorta. Study 2: Four patients with PPH (in vivo PPH group) and five patients without pulmonary hypertension and no evidence of cardiopulmonary disease (in vivo control group) were examined. The IVUS images of the apical segmental artery of the right upper lobe and the descending branch of the right pulmonary artery were studied. RESULTS Echographic examination of formalin-fixed preparations of secondary branch sections of the pulmonary artery failed to show a clear three-layer structure in the in vitro control group (24 preparations), but a distinct three-layer structure and increased vessel wall thickness were observed in the in vitro PPH group (32 preparations). Similar findings were obtained in the in vivo study. The mean echo density of the proximal pulmonary arterial wall correlated well with the mean pulmonary arterial pressure (mPA) in the in vitro PPH, and also correlated with the mPA in the in vivo study (r = 0.960, P < 0.0001). The echo intensity of secondary branch sections of the pulmonary artery was higher in the in vitro PPH group than in the in vitro control group (180.5 +/- 27.0 vs 132.5 +/- 26.7 counts, P < 0.001); similar results were obtained in the in vivo study (144.7 +/- 23.4 vs 85.0 +/- 14.3 counts, P < 0.01). CONCLUSIONS These results suggest that the histological changes detected in the pulmonary artery walls in the PPH group were responsible for the increased echo intensity.
Collapse
Affiliation(s)
- A Nakamoto
- Department of Cardiology and Pneumology, Dokkyo University School of Medicine, Tochigi, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Kal JE, Van Wezel HB, Porsius M, Vergroesen I, Spaan JA. Metabolic coronary-flow regulation and exogenous nitric oxide in human coronary artery disease: assessment by intravenous administration of nitroglycerin. J Cardiovasc Pharmacol 2000; 35:7-15. [PMID: 10630728 DOI: 10.1097/00005344-200001000-00002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
We sought to evaluate the effect of intravenous administration of the nitric oxide--donor substance nitroglycerin (NTG) on metabolic coronary-flow regulation in patients with coronary artery disease (CAD). In 12 patients with stable CAD, we measured coronary sinus blood flow and myocardial oxygen supply and consumption (MVO2) at sinus rhythm and during atrial pacing (30 beats/min above sinus rate), both at control and during infusion of NTG, 1 microg/kg/min, and NTG, 2 microg/kg/min. To study metabolic coronary vasodilation, changes in myocardial oxygen supply were related to pacing-induced changes in MVO2, by using standard regression analysis. The myocardial oxygen supply/consumption ratio (i.e., the slope of the regression line at control, characterizing physiological metabolic coronary flow regulation) was compared with the ratios obtained during infusion of NTG. Compared with control measurements, NTG, 1 microg/kg/min, and NTG, 2 microg/kg/min, attenuated pacing-induced increases in MVO2 by 29 and 60%, respectively, whereas coronary blood flow during pacing remained unchanged. At control, normal metabolic coronary-flow regulation resulted in a myocardial oxygen supply/demand ratio of 1.39 (95% CI, 1.29-1.49). This ratio did not change during NTG, 1 microg/kg/min: 1.44 (95% CI, 1.33-1.56). However, during NTG, 2 microg/kg/min, this ratio significantly increased to 1.84 (95% CI, 1.63-2.05; p<0.01). Intravenous administration of high-dose NTG, a donor of exogenous NO, blunts pacing-induced increases in MVO2 and may increase metabolic coronary vasodilation in patients with CAD.
Collapse
Affiliation(s)
- J E Kal
- Department of Anesthesiology, Academic Medical Center, University of Amsterdam, The Netherlands
| | | | | | | | | |
Collapse
|
47
|
Arbab-Zadeh A, DeMaria AN, Penny WF, Russo RJ, Kimura BJ, Bhargava V. Axial movement of the intravascular ultrasound probe during the cardiac cycle: implications for three-dimensional reconstruction and measurements of coronary dimensions. Am Heart J 1999; 138:865-72. [PMID: 10539817 DOI: 10.1016/s0002-8703(99)70011-6] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Motion of the intravascular ultrasound (IVUS) probe within the coronary artery from cardiac contraction may result in artifacts during 3-dimensional ultrasound image reconstruction and inaccurate measurements of coronary compliance. The purpose of this study was to establish whether longitudinal movement of the IVUS transducer in the coronary artery occurs and to quantify such motion. METHODS In 31 patients we positioned IVUS transducers at 59 coronary branch points: 41 in the left anterior descending coronary artery, 11 in the left circumflex coronary artery, and 7 in the right coronary artery. In each image sequence the branching vessel oscillated in and out of the imaging plane during the cardiac cycle, confirming longitudinal transducer movement. The extent of movement was estimated by IVUS from the dimension of the branch vessel traversed. In addition, angiographic visualization and measurement of IVUS probe motion was performed at 17 branch points in 12 patients. RESULTS Average longitudinal transducer movement as measured by IVUS was 1.50 +/- 0.80 mm (n = 46, range 0.5 to 5.5 mm). Because IVUS could not account for probe motion that exceeded the vessel branch diameter, the values obtained represent minimum movement. Average probe motion as assessed by cineangiography in a subset of 12 patients was 2.43 +/- 1.42 mm (range 0.57 to 6.56 mm). CONCLUSIONS This study establishes that longitudinal movement of IVUS transducers within coronary vessels occurs during the cardiac cycle. Because documented extent of motion may be sufficient to influence analysis, IVUS images are best obtained with electrocardiographic gating.
Collapse
Affiliation(s)
- A Arbab-Zadeh
- University of California at San Diego, Division of Cardiovascular Medicine, San Diego, CA, USA
| | | | | | | | | | | |
Collapse
|
48
|
Caiati C, Montaldo C, Zedda N, Montisci R, Ruscazio M, Lai G, Cadeddu M, Meloni L, Iliceto S. Validation of a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve: comparison with intracoronary Doppler flow wire. J Am Coll Cardiol 1999; 34:1193-200. [PMID: 10520812 DOI: 10.1016/s0735-1097(99)00342-3] [Citation(s) in RCA: 157] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
OBJECTIVES We tested the hypothesis that coronary flow reserve (CFR) in the left anterior descending coronary artery (LAD) as assessed by a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) is in agreement with CFR measurements assessed by intracoronary Doppler flow wire. BACKGROUND Contrast-enhanced transthoracic second harmonic echo Doppler is a novel noninvasive method to detect blood flow velocity and reserve in the LAD. However, it has not yet been validated versus a gold-standard method. METHODS Twenty-five patients undergoing CFR assessment in the LAD by Doppler flow wire were also evaluated by contrast-enhanced transthoracic Doppler to record blood flow in the distal LAD at rest and during hyperemia obtained by adenosine i.v. infusion. In five patients CFR was evaluated twice (before and after angioplasty). RESULTS As a result of the combined use of i.v. contrast and second harmonic Doppler technology, feasibility in assessing coronary flow reserve equaled 100%. The agreement between the two methods was high. In fact, in all but five patients the maximum difference between the two CFR measurements was 0.38. Overall, the prediction (95%) interval of individual differences was -0.69 to +0.72. Reproducibility of CFR measurements was also high. The limits of the agreement (95%) between the two measurements were -0.32 to +0.32. CONCLUSIONS Coronary flow reserve in the LAD as assessed by contrast-enhanced transthoracic echo Doppler along with harmonic mode concurs very closely with Doppler flow wire CFR measurements. This new noninvasive method allows feasible, reliable and reproducible assessment of CFR in the LAD.
Collapse
Affiliation(s)
- C Caiati
- Division of Cardiology, S. Maugeri Foundation, IRCCS Medical Center of Rehabilitation, Cassano Murge, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
49
|
Hildick-Smith DJ, Shapiro LM. Potential use of transthoracic echocardiography in the assessment of coronary flow reserve. J Am Soc Echocardiogr 1999; 12:590-5. [PMID: 10398918 DOI: 10.1016/s0894-7317(99)70007-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Coronary flow reserve provides a gold standard assessment of the epicardial and microvascular coronary circulation. However, measurement of coronary flow reserve is limited by the invasiveness or complexity of the methods hitherto available. We investigated whether transthoracic echocardiography could be used to assess coronary flow reserve. We imaged distal left anterior descending coronary artery diameter and flow in 14 healthy volunteers, both at rest and during intravenous infusion of adenosine (140 microg/kg per minute). Volunteers were men, with an average (+/-SD) age of 28.4 +/- 6.3 years. Complete data were acquired in 11 cases. Average distal left anterior descending coronary artery diameter was 0.213 +/- 0.03 cm. Velocity time integral rose from 8.6 +/- 2.1 cm to 27.7 +/- 5.6 cm with adenosine infusion. Heart rate rose from 64.7 +/- 9. 8 to 75.3 +/- 11.7 bpm. The Doppler angle of incidence to flow was 42.4 +/- 8.7 degrees. Resting distal left anterior descending coronary artery flow was therefore calculated as 13.4 +/- 3.2 mL/min and hyperemic flow as 51.2 +/- 16.2 mL/min, yielding a coronary flow reserve of 3.81 +/- 0.6. We conclude that coronary flow reserve can be assessed in a selected population with the use of transthoracic echocardiography and an intravenous infusion of adenosine. The simplicity of this noninvasive technique suggests that it could become a useful tool for measurement of coronary flow reserve if imaging success rates can be optimized.
Collapse
|
50
|
Karila-Cohen D, Delpy E, Dubois-Randé JL, Puybasset L, Hittinger L, Giudicelli JF, Berdeaux A. Influence of the endothelium, nitric oxide and serotonergic receptors on coronary vasomotor responses evoked by ergonovine in conscious dogs. Br J Pharmacol 1999; 127:1039-47. [PMID: 10433513 PMCID: PMC1566101 DOI: 10.1038/sj.bjp.0702635] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
1. The respective contributions of coronary vascular endothelium, nitric oxide (NO) and serotonergic receptors to the effects of ergonovine on large and small coronary arteries were investigated in conscious dogs. 2. In seven dogs with an endothelium intact, ergonovine (30 - 1000 microg, i.v.) induced a biphasic response on large coronary artery with an early and transient vasodilatation (up to +2.9+/-0.5% from 3310+/-160 microm, P<0.01) followed by a sustained vasoconstriction (down to -4.9+/-0.5%, P<0.001) which occurred simultaneously with a sustained increase in coronary blood flow (CBF) (up to +100+/-26% from 28+/-4 ml min(-1), P<0.001). After endothelium removal (balloon angioplasty), the ergonovine-induced vasodilatation was abolished and vasoconstriction potentiated (-6.4+/-0.9% after vs -4.9+/-0.5% before endothelium removal, P<0.01). 3. After blockade of NO synthesis by Nomega-nitro-L-arginine (30 mg kg(-1)) in four other dogs, the early vasodilatation induced by ergonovine was abolished but the delayed vasoconstriction as well as the increase in CBF remained unchanged. 4. Both ketanserin and methiothepin (0.3 mg kg(-1)) abolished the early vasodilatation and reduced the delayed vasoconstriction induced by ergonovine. Ketanserin decreased and methiothepin abolished the reduction in coronary resistance induced by ergonovine. 5. Thus, the complex interactions between vascular endothelium and serotonergic receptors to ergonovine-induced constriction of large coronary arteries might explain the induction of coronary spasms in patients with endothelial dysfunction.
Collapse
Affiliation(s)
- D Karila-Cohen
- Département de Pharmacologie, Faculté de Médecine Paris-Sud, Le Kremlin Bicêtre, France
| | | | | | | | | | | | | |
Collapse
|