1
|
Implementation of a new integrated d-lactic acid biosensor in a semiautomatic FIA system for the simultaneous determination of lactic acid enantiomers. Application to the analysis of beer samples. Talanta 2016; 152:147-54. [DOI: 10.1016/j.talanta.2016.01.063] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 01/22/2016] [Accepted: 01/30/2016] [Indexed: 11/21/2022]
|
2
|
Pakapongpan S, Mensing JP, Phokharatkul D, Lomas T, Tuantranont A. Highly selective electrochemical sensor for ascorbic acid based on a novel hybrid graphene-copper phthalocyanine-polyaniline nanocomposites. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2014.03.167] [Citation(s) in RCA: 74] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
3
|
Sekretaryova AN, Vagin MY, Beni V, Turner AP, Karyakin AA. Unsubstituted phenothiazine as a superior water-insoluble mediator for oxidases. Biosens Bioelectron 2014; 53:275-82. [DOI: 10.1016/j.bios.2013.09.071] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2013] [Revised: 09/13/2013] [Accepted: 09/26/2013] [Indexed: 11/28/2022]
|
4
|
Vargas E, Gamella M, Campuzano S, Guzmán-Vázquez de Prada A, Ruiz M, Reviejo A, Pingarrón J. Development of an integrated electrochemical biosensor for sucrose and its implementation in a continuous flow system for the simultaneous monitoring of sucrose, fructose and glucose. Talanta 2013; 105:93-100. [DOI: 10.1016/j.talanta.2012.11.058] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2012] [Revised: 11/22/2012] [Accepted: 11/24/2012] [Indexed: 10/27/2022]
|
5
|
References. Anal Chem 2012. [DOI: 10.1201/b11478-14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
6
|
Conzuelo F, Gamella M, Campuzano S, Ruiz MA, Reviejo AJ, Pingarrón JM. An integrated amperometric biosensor for the determination of lactose in milk and dairy products. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2010; 58:7141-7148. [PMID: 20509693 DOI: 10.1021/jf101173e] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
An integrated amperometric biosensor for the determination of lactose is reported. The bioelectrode design is based on the use of a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)-modified gold electrode on which the enzymes beta-galactosidase (beta-Gal), glucose oxidase (GOD), peroxidase (HRP) and the mediator tetrathiafulvalene (TTF) are coimmobilized by a dialysis membrane. beta-Gal catalyzes the hydrolysis of lactose, and the produced glucose is catalytically oxidized to gluconic acid and H(2)O(2), which is reduced in the presence of HRP. This enzyme reaction is mediated by TTF, and the reduction of TTF(+) at 0.00 V (vs Ag/AgCl) gives rise to an amperometric signal proportional to the lactose concentration. The biosensor exhibits a good repeatability of the measurement carried out with the same biosensor, a good reproducibility of the responses obtained with different biosensors and a useful lifetime of 28 days. A linear calibration plot was obtained for lactose over the 1.5 x 10(-6) to 1.2 x 10(-4) M concentration range, with a limit of detection of 4.6 x 10(-7) M. The effect of potential interferents (sucrose, lactulose, fructose, arabinose, maltose, galactose, glucose and uric and ascorbic acids) on the biosensor response was evaluated. Furthermore, the bioelectrode exhibits a suitable performance in flow-injection systems in connection with amperometric detection. The developed biosensor was applied to the determination of lactose in milk and other foodstuffs (chocolate, butter, margarine, yogurt, cheese and mayonnaise), and the results obtained were validated by comparison with those provided by using a commercial enzyme test kit.
Collapse
Affiliation(s)
- F Conzuelo
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, Madrid, Spain
| | | | | | | | | | | |
Collapse
|
7
|
Integrated multienzyme electrochemical biosensors for monitoring malolactic fermentation in wines. Talanta 2010; 81:925-33. [DOI: 10.1016/j.talanta.2010.01.038] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2009] [Revised: 01/11/2010] [Accepted: 01/17/2010] [Indexed: 11/24/2022]
|
8
|
Gamella M, Campuzano S, Reviejo AJ, Pingarrón JM. Integrated multienzyme electrochemical biosensors for the determination of glycerol in wines. Anal Chim Acta 2008; 609:201-9. [PMID: 18261515 DOI: 10.1016/j.aca.2007.12.036] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2007] [Revised: 12/20/2007] [Accepted: 12/24/2007] [Indexed: 10/22/2022]
Abstract
The construction and performance of integrated amperometric biosensors for the determination of glycerol are reported. Two different biosensor configurations have been evaluated: one based on the glycerol dehydrogenase/diaphorase (GDH/DP) bienzyme system, and another using glycerol kinase/glycerol-3-phosphate oxidase/peroxidase (GK/GPOx/HRP). Both enzyme systems were immobilized together with the mediator tetrathiafulvalene (TTF) on a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)-modified gold electrode by using a dialysis membrane. The electrochemical oxidation of TTF at +150mV (vs. Ag/AgCl), and the reduction of TTF(+) at 0mV were used for the monitoring of the enzyme reactions for the bienzyme and trienzyme configurations, respectively. Experimental variables concerning both the biosensors composition and the working conditions were optimized for each configuration. A good repeatability of the measurements with no need of cleaning or pretreatment of the biosensors was obtained in both cases. After 51 days of use, the GDH/DP biosensor still exhibited 87% of the original sensitivity, while the GK/GPOx/HRP biosensor yielded a 46% of the original response after 8 days. Calibration graphs for glycerol with linear ranges of 1.0x10(-6) to 2.0x10(-5) or 1.0x10(-6) to 1.0x10(-5)M glycerol and sensitivities of 1214+/-21 or 1460+/-34microAM(-1) were obtained with GDH/DP and GK/GPOx/HRP biosensors, respectively. The calculated detection limits were 4.0x10(-7) and 3.1x10(-7)M, respectively. The biosensors exhibited a great sensitivity with no significant interferences in the analysis of wines. The biosensors were applied to the determination of glycerol in 12 different wines and the results advantageously compared with those provided by a commercial enzyme kit.
Collapse
Affiliation(s)
- M Gamella
- Dpto. Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain
| | | | | | | |
Collapse
|
9
|
Ramos LA, Cavalheiro ETG, Chierice GO. Evaluation of the electrochemical behavior and analytical potentialities of a carbon paste electrode modified with a ruthenium (III) piperidinedithiocarbamate complex. FARMACO (SOCIETA CHIMICA ITALIANA : 1989) 2005; 60:149-55. [PMID: 15752473 DOI: 10.1016/j.farmac.2004.11.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2004] [Revised: 10/30/2004] [Accepted: 11/23/2004] [Indexed: 10/25/2022]
Abstract
The preparation and electrochemical characterization of a carbon paste electrode modified with bis(N,N-piperidinedithiocarbamate)-mu-tris(N,N-piperidinedithiocarbamate)diruthenium(III) complex, alpha-[Ru2(Pip)5]Cl are described. The best voltammetric response was obtained for a 10% (m/m) alpha-[Ru2(Pip)5]Cl content in the paste, potassium acid phthalate solution pH 4.0 as supporting electrolyte and scan rate of 100 mV s-1. The analytical potentialities of the electrode have been evaluated using L-ascorbic acid (vitamin C) as a probe. A sensitive linear voltammetric response for L-ascorbic acid was obtained in the concentration range 4.50-113x10(-5) mol l-1 (7.92-200 mg l-1) with a slope of 1.12x10(4) microA mol-1, and a detection limit (3sigma/slope) of 7.00x10(-6) mol l-1 using cyclic voltammetry. The concentrations of L-ascorbic acid in pharmaceutical formulations (tablets and liquid) were determined using the modified electrode and compared with an iodimetric procedure with good agreement at the 95% confidence and relative error lower than 1%.
Collapse
Affiliation(s)
- Luiz Antônio Ramos
- Departamento de Química e Física Molecular, Instituto de Química de São Carlos, USP Caixa Postal 780, CEP 13560-970, São Carlos, SP, Brazil
| | | | | |
Collapse
|
10
|
Campuzano S, Loaiza OA, Pedrero M, de Villena FJM, Pingarrón JM. An integrated bienzyme glucose oxidase–fructose dehydrogenase–tetrathiafulvalene-3-mercaptopropionic acid–gold electrode for the simultaneous determination of glucose and fructose. Bioelectrochemistry 2004; 63:199-206. [PMID: 15110273 DOI: 10.1016/j.bioelechem.2003.10.019] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2003] [Revised: 10/06/2003] [Accepted: 10/08/2003] [Indexed: 10/26/2022]
Abstract
A bienzyme biosensor for the simultaneous determination of glucose and fructose was developed by coimmobilising glucose oxidase (GOD), fructose dehydrogenase (FDH), and the mediator, tetrathiafulvalene (TTF), by cross-linking with glutaraldehyde atop a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM) on a gold disk electrode (AuE). The performance of this bienzyme electrode under batch and flow injection (FI) conditions, as well as an amperometric detection in high-performance liquid chromatography (HPLC), are reported. The order of enzyme immobilisation atop the MPA-SAM affected the biosensor amperometric response in terms of sensitivity, with the immobilisation order GOD, FDH, TTF being selected. Similar analytical characteristics to those obtained with single GOD or FDH SAM-based biosensors for glucose and fructose were achieved with the bienzyme electrode, indicating that no noticeable changes in the biosensor responses to the analytes occurred as a consequence of the coimmobilisation of both enzymes on the same MPA-AuE. The suitability of the bienzyme biosensor for the analysis of real samples under flow injection conditions was tested by determining glucose in two certified serum samples. The simultaneous determination of glucose and fructose in the same sample cannot be performed without a separation step because at the detection potential used (+0.10 V), both sugars show amperometric response. Consequently, HPLC with amperometric detection at the TTF-FDH-GOD-MPA-AuE was accomplished. Glucose and fructose were simultaneously determined in honey, cola softdrink, and commercial apple juice, and the results were compared with those obtained by using other reference methods.
Collapse
Affiliation(s)
- Susana Campuzano
- Departamento de Química Analítica, Facultad de CC Químicas, Universidad Complutense de Madrid, Madrid E-28040, Spain
| | | | | | | | | |
Collapse
|
11
|
Abstract
A new type of sol-gel-derived titanium oxide/copolymer composite material was developed and used for the construction of glucose biosensor. The composite material merged the best properties of the inorganic species, titanium oxide and the organic copolymer, poly(vinyl alcohol) grafting 4-vinylpyridine (PVA-g-PVP). The glucose oxidase entrapped in the composite matrix retained its bioactivity. Morphologies of the composite-modified electrode and the enzyme electrode were characterized with a scanning electron microscope. The dependence of the current responses on enzyme-loading and pH was studied. The response time of the biosensor was < 20 s and the linear range was up to 9 microM with a sensitivity of 405 nA/microM. The biosensor was stable for at least 1 month. In addition, the tetrathiafulvalene-mediated enzyme electrode was constructed for the decrease of detection potential and the effect of three common physiological sources that might interfere was also investigated.
Collapse
Affiliation(s)
- Xu Chen
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, People's Republic of China
| | | |
Collapse
|
12
|
Teixeira MFS, Ramos LA, Fatibello-Filho O, Cavalheiro ETG. Carbon paste electrode modified with copper (II) phosphate immobilized in a polyester resin for voltammetric determination of L-ascorbic acid in pharmaceutical formulations. Anal Bioanal Chem 2003; 376:214-9. [PMID: 12677341 DOI: 10.1007/s00216-003-1866-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2002] [Revised: 02/05/2003] [Accepted: 02/10/2003] [Indexed: 10/20/2022]
Abstract
A carbon paste electrode modified with copper(II) phosphate immobilized in a polyester resin (CuP-Poly) is proposed for voltammetric determination of L-ascorbic acid in pharmaceutical formulations. The modified electrode allows the detection of L-ascorbic acid at lower anodic potentials than observed at unmodified electrodes. Several parameters that can influence the voltammetric response of the proposed electrode such as carbon paste composition, pH, scan rate, and possible interference were investigated. The peak current was proportional to the concentration of ascorbic acid in the range 2.0 x 10(-5) to 3.2 x 10(-3) mol L(-1) with a detection limit of 1.0 x 10(-5) mol L(-1). The stability and repeatability of the electrode for the determination of L-ascorbic acid are also discussed. Amperometric response was also recorded for electrocatalytic oxidation of the L-ascorbic acid. Concentrations of the vitamin C in pharmaceutical formulations (tablets) measured using the modified electrode and a titrimetric method are in agreement at the 95% confidence level and within an acceptable range of error.
Collapse
Affiliation(s)
- Marcos F S Teixeira
- Departamento de Química, Centro de Ciências Exatas e de Tecnologia, Universidade Federal de São Carlos, Caixa Postal 676, CEP 13.560-970, São Carlos, SP, Brazil.
| | | | | | | |
Collapse
|
13
|
Abstract
Direct electrode transfer between enzyme and the electrode in biosensors requires high efficiency therefore, synthetic replacement for oxygen led to the development of enzyme mediators and modified electrodes in biosensor fabrication. In this context, a number of electron acceptors and complexes have been used. Present paper gives an overview of various methodologies involved in the mediated systems, their merits and wide applications.
Collapse
Affiliation(s)
- Asha Chaubey
- Biomolecular Electronics and Conducting Polymer Research Group, National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110 012, India.
| | | |
Collapse
|
14
|
Wang J, Wu Z, Tang J, Teng R, Wang E. Electrocatalytic Oxidation of Ascorbic Acid by Ferrocene in Lipid Film Cast on a Glassy Carbon Electrode. ELECTROANAL 2001. [DOI: 10.1002/1521-4109(200109)13:13<1093::aid-elan1093>3.0.co;2-b] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
15
|
Han X, Tang J, Wang J, Wang E. Electrocatalytic oxidation of ascorbic acid by norepinephrine embedded in lipid cast film at glassy carbon electrode. Electrochim Acta 2001. [DOI: 10.1016/s0013-4686(01)00542-4] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
Murthy ASN, Sharma J. Electrocatalytic oxidation of ascorbic acid using benzoquinone as a mediator. ELECTROANAL 1997. [DOI: 10.1002/elan.1140090914] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
17
|
Voltammetric characterisation of an insoluble tetrathiafulvalene derivative by means of modified carbon paste electrode. Anal Chim Acta 1996. [DOI: 10.1016/s0003-2670(96)00330-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|