1
|
Sundaravadivelu D, Sanan TT, Venkatapathy R, Mash H, Tettenhorst D, DAnglada L, Frey S, Tatters AO, Lazorchak J. Determination of Cyanotoxins and Prymnesins in Water, Fish Tissue, and Other Matrices: A Review. Toxins (Basel) 2022; 14:toxins14030213. [PMID: 35324710 PMCID: PMC8949488 DOI: 10.3390/toxins14030213] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/10/2022] [Accepted: 03/13/2022] [Indexed: 12/10/2022] Open
Abstract
Harmful algal blooms (HABs) and their toxins are a significant and continuing threat to aquatic life in freshwater, estuarine, and coastal water ecosystems. Scientific understanding of the impacts of HABs on aquatic ecosystems has been hampered, in part, by limitations in the methodologies to measure cyanotoxins in complex matrices. This literature review discusses the methodologies currently used to measure the most commonly found freshwater cyanotoxins and prymnesins in various matrices and to assess their advantages and limitations. Identifying and quantifying cyanotoxins in surface waters, fish tissue, organs, and other matrices are crucial for risk assessment and for ensuring quality of food and water for consumption and recreational uses. This paper also summarizes currently available tissue extraction, preparation, and detection methods mentioned in previous studies that have quantified toxins in complex matrices. The structural diversity and complexity of many cyanobacterial and algal metabolites further impede accurate quantitation and structural confirmation for various cyanotoxins. Liquid chromatography–triple quadrupole mass spectrometer (LC–MS/MS) to enhance the sensitivity and selectivity of toxin analysis has become an essential tool for cyanotoxin detection and can potentially be used for the concurrent analysis of multiple toxins.
Collapse
Affiliation(s)
| | - Toby T. Sanan
- Office of Research and Development, Center for Environmental Solutions and Emergency Response, U.S. EPA, Cincinnati, OH 45268, USA; (H.M.); (D.T.)
- Correspondence: (T.T.S.); (J.L.); Tel.: +1-513-569-7076 (J.L.)
| | | | - Heath Mash
- Office of Research and Development, Center for Environmental Solutions and Emergency Response, U.S. EPA, Cincinnati, OH 45268, USA; (H.M.); (D.T.)
| | - Dan Tettenhorst
- Office of Research and Development, Center for Environmental Solutions and Emergency Response, U.S. EPA, Cincinnati, OH 45268, USA; (H.M.); (D.T.)
| | - Lesley DAnglada
- Office of Water, Science and Technology, U.S. EPA, Washington, DC 20004, USA; (L.D.); (S.F.)
| | - Sharon Frey
- Office of Water, Science and Technology, U.S. EPA, Washington, DC 20004, USA; (L.D.); (S.F.)
| | - Avery O. Tatters
- Center for Environmental Measurement and Modeling, U.S. EPA, Gulf Breeze, FL 32561, USA;
| | - James Lazorchak
- Center for Environmental Measurement and Modeling, U.S. EPA, Cincinnati, OH 45268, USA
- Correspondence: (T.T.S.); (J.L.); Tel.: +1-513-569-7076 (J.L.)
| |
Collapse
|
2
|
Liu J, Xing Y, Zhou X, Chen GY, Shi H. Light-sheet skew rays enhanced U-shaped fiber-optic fluorescent immunosensor for Microcystin-LR. Biosens Bioelectron 2021; 176:112902. [PMID: 33341317 DOI: 10.1016/j.bios.2020.112902] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 12/06/2020] [Accepted: 12/09/2020] [Indexed: 02/06/2023]
Abstract
A novel U-shaped fiber-optic evanescent-wave fluorescent immunosensor was designed that exploits light-sheet excitation of skew rays in a passive fiber for sensitive microcystin-LR (MC-LR) detection in real-time. In particular, a light sheet comprising a thin plane of light can be concentrated into exciting the optimum ray group, resulting in enhanced interaction between light and fluorophores. Meanwhile, skew rays excited by transmitting light into an optical fiber with an angle offset allow a much higher number of total-internal-reflections with increased interaction length along the fiber interface, which strengthens the light-matter interactions. Under the optimal angle offset, the proposed evanescent wave fluorescent immunosensor is the first demonstration of integrating light-sheet skew rays and a U-shaped fiber-optic probe for enhanced sensitivity. The results show that fluorescence sensitivity of the U-shaped fiber-optic probe with light-sheet skew rays excitation is 16 times higher than that of collimated skew rays excitation. Combined with this newly designed light-sheet skew rays enhanced U-shaped fiber-optic fluorescent immunosensor, a sensitive and real-time MC-LR detection method was established based on the indirect competitive immunoassay principle. Real environmental water samples spiked with MC-LR were determined by the immunosensor with recovery rates between 85% and 112%. The present system could be an alternative tool for the on-site environmental monitoring, in-field food safety assurance and clinical diagnostics. It also advances the fiber-optic sensors field in terms of experimental design.
Collapse
Affiliation(s)
- Jinchuan Liu
- State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Yunpeng Xing
- State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Xiaohong Zhou
- State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing, 100084, China.
| | - George Y Chen
- Laser Physics and Photonic Devices Laboratories, UniSA STEM, University of South Australia, Mawson Lakes, South Australia, 5095, Australia.
| | - Hanchang Shi
- State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
3
|
Recent Advances in Information and Communications Technology (ICT) and Sensor Technology for Monitoring Water Quality. WATER 2020. [DOI: 10.3390/w12020510] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Water quality control and management in water resources are important for providing clean and safe water to the public. Due to their large area, collection, analysis, and management of a large amount of water quality data are essential. Water quality data are collected mainly by manual field sampling, and recently real-time sensor monitoring has been increasingly applied for efficient data collection. However, real-time sensor monitoring still relies on only a few parameters, such as water level, velocity, temperature, conductivity, dissolved oxygen (DO), and pH. Although advanced sensing technologies, such as hyperspectral images (HSI), have been used for the areal monitoring of algal bloom, other water quality sensors for organic compounds, phosphorus (P), and nitrogen (N) still need to be further developed and improved for field applications. The utilization of information and communications technology (ICT) with sensor technology shows great potential for the monitoring, transmission, and management of field water-quality data and thus for developing effective water quality management. This paper presents a review of the recent advances in ICT and field applicable sensor technology for monitoring water quality, mainly focusing on water resources, such as rivers and lakes, and discusses the challenges and future directions.
Collapse
|
4
|
Tripathi SM, Dandapat K, Bock WJ, Mikulic P, Perreault J, Sellamuthu B. Gold coated dual-resonance long-period fiber gratings (DR-LPFG) based aptasensor for cyanobacterial toxin detection. SENSING AND BIO-SENSING RESEARCH 2019. [DOI: 10.1016/j.sbsr.2019.100289] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
|
5
|
Picardo M, Filatova D, Nuñez O, Farré M. Recent advances in the detection of natural toxins in freshwater environments. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.12.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
6
|
Development of novel portable and reusable fiber optical chemiluminescent biosensor and its application for sensitive detection of microcystin-LR. Biosens Bioelectron 2018; 121:27-33. [DOI: 10.1016/j.bios.2018.08.062] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 08/22/2018] [Accepted: 08/25/2018] [Indexed: 11/21/2022]
|
7
|
Bickman SR, Campbell K, Elliott C, Murphy C, O'Kennedy R, Papst P, Lochhead MJ. An Innovative Portable Biosensor System for the Rapid Detection of Freshwater Cyanobacterial Algal Bloom Toxins. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:11691-11698. [PMID: 30208702 DOI: 10.1021/acs.est.8b02769] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Harmful algal blooms in freshwater systems are increasingly common and present threats to drinking water systems, recreational waters, and ecosystems. A highly innovative simple to use, portable biosensor system (MBio) for the rapid and simultaneous detection of multiple cyanobacterial toxins in freshwater is demonstrated. The system utilizes a novel planar waveguide optical sensor that delivers quantitative fluorescent competitive immunoassay results in a disposable cartridge. Data are presented for the world's first duplex microcystin (MC)/cylindrospermopsin (CYN) assay cartridge using a combination of fluorophore-conjugated monoclonal antibodies as detector molecules. The on-cartridge detection limits of 20% inhibitory concentration (IC20) was 0.4 μg/L for MC and 0.7 μg/L for CYN. MC assay coverage of eight important MC congeners was demonstrated. Validation using 45 natural lake water samples from Colorado and Lake Erie showed quantitative correlation with commercially available laboratory-based enzyme linked immunosorbent assays. A novel cell lysis module was demonstrated using cyanobacteria cultures. Results show equivalent or better performance than the gold-standard but more tedious 3× freeze-thaw method, with >90% cell lysis for laboratory cultures. The MBio system holds promise as a versatile tool for multiplexed field-based cyanotoxin detection, with future analyte expansion including saxitoxin, anatoxin-a, and marine biotoxins.
Collapse
Affiliation(s)
- Sarah R Bickman
- MBio Diagnostics, Inc. , 5603 Arapahoe Ave , Boulder , Colorado 80303 , United States
| | - Katrina Campbell
- Institute for Global Food Security, School of Biological Sciences , Queen's University, Belfast , Stranmillis Road , Belfast , United Kingdom , BT9 5AG
| | - Christopher Elliott
- Institute for Global Food Security, School of Biological Sciences , Queen's University, Belfast , Stranmillis Road , Belfast , United Kingdom , BT9 5AG
| | - Caroline Murphy
- School of Biotechnology, National Centre for Sensor Research and Biomedical Diagnostics Institute , Dublin City University , Dublin 9 , Ireland
| | - Richard O'Kennedy
- School of Biotechnology, National Centre for Sensor Research and Biomedical Diagnostics Institute , Dublin City University , Dublin 9 , Ireland
| | - Philip Papst
- MBio Diagnostics, Inc. , 5603 Arapahoe Ave , Boulder , Colorado 80303 , United States
| | - Michael J Lochhead
- MBio Diagnostics, Inc. , 5603 Arapahoe Ave , Boulder , Colorado 80303 , United States
| |
Collapse
|
8
|
Pyo D, Yim M. Comparison of strip analysis and HPLC analysis for the quantitative analysis of cyanobacterial toxin. ANALYTICAL SCIENCE AND TECHNOLOGY 2015. [DOI: 10.5806/ast.2015.28.3.168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
9
|
McNamee SE, Elliott CT, Greer B, Lochhead M, Campbell K. Development of a planar waveguide microarray for the monitoring and early detection of five harmful algal toxins in water and cultures. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:13340-9. [PMID: 25361072 DOI: 10.1021/es504172j] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A novel multiplex microarray has been developed for the detection of five groups of harmful algal and cyanobacterial toxins found in marine, brackish, and freshwater environments including domoic acid (DA), okadaic acid (OA, and analogues), saxitoxin (STX, and analogues), cylindrospermopsin (CYN) and microcystins (MC, and analogues). The sensitivity and specificity were determined and feasibility to be used as a screening tool investigated. Results for algal/cyanobacterial cultures (n = 12) and seawater samples (n = 33) were compared to conventional analytical methods, such as high performance liquid chromatography (HPLC) and liquid chromatography tandem mass spectrometry (LC-MS/MS). Detection limits for the 15 min assay were 0.37, 0.44, 0.05, 0.08, and 0.40 ng/mL for DA, OA, STX, CYN, and MC, respectively. The correlation of data obtained from the microarray compared to conventional analysis for the 12 cultures was r(2) = 0.83. Analysis of seawater samples showed that 82, 82, 70, 82, and 12% of samples were positive (>IC20) compared to 67, 55, 36, 0, and 0% for DA, OA, STX, CYN, and MC, respectively, for conventional analytical methods. The discrepancies in results can be attributed to the enhanced sensitivity and cross-reactivity profiles of the antibodies in the MBio microarray. The feasibility of the microarray as a rapid, easy to use, and highly sensitive screening tool has been illustrated for the five-plex detection of biotoxins. The research demonstrates an early warning screening assay to support national monitoring agencies by providing a faster and more accurate means of identifying and quantifying harmful toxins in water samples.
Collapse
Affiliation(s)
- Sara E McNamee
- Institute for Global Food Security, School of Biological Sciences, Queen's University , Stranmillis Road, Belfast BT9 5AG, United Kingdom
| | | | | | | | | |
Collapse
|
10
|
Liu L, Xing C, Yan H, Kuang H, Xu C. Development of an ELISA and immunochromatographic strip for highly sensitive detection of microcystin-LR. SENSORS (BASEL, SWITZERLAND) 2014; 14:14672-85. [PMID: 25120158 PMCID: PMC4179011 DOI: 10.3390/s140814672] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Revised: 08/03/2014] [Accepted: 08/06/2014] [Indexed: 01/16/2023]
Abstract
A monoclonal antibody for microcystin-leucine-arginine (MC-LR) was produced by cell fusion. The immunogen was synthesized in two steps. First, ovalbumin/ bovine serum albumin was conjugated with 6-acetylthiohexanoic acid using a carbodiimide EDC (1-ethyl-3-[3-dimethylaminopropyl]carbodiimide hydrochloride)/ NHS (N-hydroxysulfosuccinimide) reaction. After dialysis, the protein was reacted with MC-LR based on a free radical reaction under basic solution conditions. The protein conjugate was used for immunization based on low volume. The antibodies were identified by indirect competitive (ic)ELISA and were subjected to tap water and lake water analysis. The concentration causing 50% inhibition of binding of MC-LR (IC50) by the competitive indirect ELISA was 0.27 ng/mL. Cross-reactivity to the MC-RR, MC-YR and MC-WR was good. The tap water and lake water matrices had no effect on the detection limit. The analytical recovery of MC-LR in the water samples in the icELISA was 94%-110%. Based on this antibody, an immunochromatographic biosensor was developed with a cut-off value of 1 ng/mL, which could satisfy the requirement of the World Health Organization for MC-LR detection in drinking water. This biosensor could be therefore be used as a fast screening tool in the field detection of MC-LR.
Collapse
Affiliation(s)
- Liqiang Liu
- State Key Lab of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, JiangSu 214122, China.
| | - Changrui Xing
- State Key Lab of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, JiangSu 214122, China.
| | - Huijuan Yan
- State Key Lab of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, JiangSu 214122, China.
| | - Hua Kuang
- State Key Lab of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, JiangSu 214122, China.
| | - Chuanlai Xu
- State Key Lab of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi, JiangSu 214122, China.
| |
Collapse
|
11
|
Eissa S, Ng A, Siaj M, Zourob M. Label-free voltammetric aptasensor for the sensitive detection of microcystin-LR using graphene-modified electrodes. Anal Chem 2014; 86:7551-7. [PMID: 25011536 DOI: 10.1021/ac501335k] [Citation(s) in RCA: 96] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
The development of successful biosensing platforms is highly dependent upon the biorecognition properties of the recognition receptor and the sensitivity of the transducer of the binding signal. The integration of the high affinity and specificity of DNA aptamers with the unique properties of the carbon nanomaterial graphene offers an excellent avenue for sensitive and selective biosensing architectures. In this work, a highly sensitive and selective aptasensor which utilizes an unlabeled DNA aptamer assembled on a graphene electrode for microcystin-LR detection was developed. A facile strategy was used for the aptasensor fabrication on the basis of the noncovalent assembly of DNA aptamer on graphene-modified screen printed carbon electrodes. Assembly of the DNA aptamer on the graphene-modified electrodes caused a marked drop in the square wave voltammetric reduction signal of the [Fe(CN)6](4-/3-) redox couple. The presence of microcystin-LR, on the other hand, caused a dose-responsive increase in peak current, allowing the quantification of microcystin-LR through the measurement of peak current change. Under optimal conditions, the detection limit of the developed aptasensor was 1.9 pM in buffer, a concentration much lower than those offered by previously reported biosensors for microcystin-LR. The developed aptasensor also exhibited excellent selectivity for microcystin-LR with no detectable cross-reactivity to okadaic acid, microcystin-LA, and microcystin-YR. Moreover, the proposed aptasensor has been applied for the analysis of spiked tap water and fish samples showing good recovery percentages. This novel, simple, high-performance, and low-cost detection platform would facilitate the routine monitoring of microcystin-LR in real samples.
Collapse
Affiliation(s)
- Shimaa Eissa
- Institut National de la Recherche Scientifique, Centre - Énergie, Matériaux et Télécommunications, 1650 Boulevard Lionel Boulet, Varennes, Québec J3X 1S2, Canada
| | | | | | | |
Collapse
|
12
|
Immunoassays and biosensors for the detection of cyanobacterial toxins in water. SENSORS 2013; 13:15085-112. [PMID: 24196435 PMCID: PMC3871135 DOI: 10.3390/s131115085] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2013] [Revised: 10/11/2013] [Accepted: 10/14/2013] [Indexed: 12/16/2022]
Abstract
Algal blooms are a frequent phenomenon in nearly all kinds of fresh water. Global warming and eutrophication by waste water, air pollution and fertilizers seem to lead to an increased frequency of occurrence. Many cyanobacteria produce hazardous and quite persistent toxins, which can contaminate the respective water bodies. This may limit the use of the raw water for many purposes. The purification of the contaminated water might be quite costly, which makes a continuous and large scale treatment economically unfeasible in many cases. Due to the obvious risks of algal toxins, an online or mobile detection method would be highly desirable. Several biosensor systems have been presented in the literature for this purpose. In this review, their mode of operation, performance and general suitability for the intended purpose will be described and critically discussed. Finally, an outlook on current developments and future prospects will be given.
Collapse
|
13
|
Merel S, Walker D, Chicana R, Snyder S, Baurès E, Thomas O. State of knowledge and concerns on cyanobacterial blooms and cyanotoxins. ENVIRONMENT INTERNATIONAL 2013; 59:303-27. [PMID: 23892224 DOI: 10.1016/j.envint.2013.06.013] [Citation(s) in RCA: 471] [Impact Index Per Article: 42.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2012] [Revised: 06/12/2013] [Accepted: 06/18/2013] [Indexed: 05/17/2023]
Abstract
Cyanobacteria are ubiquitous microorganisms considered as important contributors to the formation of Earth's atmosphere and nitrogen fixation. However, they are also frequently associated with toxic blooms. Indeed, the wide range of hepatotoxins, neurotoxins and dermatotoxins synthesized by these bacteria is a growing environmental and public health concern. This paper provides a state of the art on the occurrence and management of harmful cyanobacterial blooms in surface and drinking water, including economic impacts and research needs. Cyanobacterial blooms usually occur according to a combination of environmental factors e.g., nutrient concentration, water temperature, light intensity, salinity, water movement, stagnation and residence time, as well as several other variables. These environmental variables, in turn, have promoted the evolution and biosynthesis of strain-specific, gene-controlled metabolites (cyanotoxins) that are often harmful to aquatic and terrestrial life, including humans. Cyanotoxins are primarily produced intracellularly during the exponential growth phase. Release of toxins into water can occur during cell death or senescence but can also be due to evolutionary-derived or environmentally-mediated circumstances such as allelopathy or relatively sudden nutrient limitation. Consequently, when cyanobacterial blooms occur in drinking water resources, treatment has to remove both cyanobacteria (avoiding cell lysis and subsequent toxin release) and aqueous cyanotoxins previously released. Cells are usually removed with limited lysis by physical processes such as clarification or membrane filtration. However, aqueous toxins are usually removed by both physical retention, through adsorption on activated carbon or reverse osmosis, and chemical oxidation, through ozonation or chlorination. While the efficient oxidation of the more common cyanotoxins (microcystin, cylindrospermopsin, anatoxin and saxitoxin) has been extensively reported, the chemical and toxicological characterization of their by-products requires further investigation. In addition, future research should also investigate the removal of poorly considered cyanotoxins (β-methylamino-alanine, lyngbyatoxin or aplysiatoxin) as well as the economic impact of blooms.
Collapse
Affiliation(s)
- Sylvain Merel
- Department of Chemical and Environmental Engineering, University of Arizona, 1133 James E. Rogers Way, Tucson, AZ 85721, USA.
| | | | | | | | | | | |
Collapse
|
14
|
Shi HC, Song BD, Long F, Zhou XH, He M, Lv Q, Yang HY. Automated online optical biosensing system for continuous real-time determination of microcystin-LR with high sensitivity and specificity: early warning for cyanotoxin risk in drinking water sources. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:4434-41. [PMID: 23514076 DOI: 10.1021/es305196f] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The accelerated eutrophication of surface water sources and climate change have led to an annual occurrence of cyanobacterial blooms in many drinking water resources. To minimize the health risks to the public, cyanotoxin detection methods that are rapid, sensitive, real time, and high frequency must be established. In this study, an innovative automated online optical biosensing system (AOBS) was developed for the rapid detection and early warning of microcystin-LR (MC-LR), one of the most toxic cyanotoxins and most frequently detected in environmental water. In this system, the capturing molecular MC-LR-ovalbumin (MC-LR-OVA) was covalently immobilized onto a biochip surface. By an indirect competitive detection mode, samples containing different concentrations of MC-LR were premixed with a certain concentration of fluorescence-labeled anti-MC-LR-mAb, which binds to MC-LR with high specificity. Then, the sample mixture was pumped onto the biochip surface, and a higher concentration of MC-LR led to less fluorescence-labeled antibody bound onto the biochip surface and thus to lower fluorescence signal. The quantification of MC-LR ranges from 0.2 to 4 μg/L, with a detection limit determined as 0.09 μg/L. The high specificity and selectivity of the sensor were evaluated in terms of its response to a number of potentially interfering cyanotoxins. Potential interference of the environmental sample matrix was assessed by spiked samples, and the recovery of MC-LR ranged from 90 to 120% with relative standard deviation values <8%. The immunoassay performance of the AOBS was validated with respect to that of conventional high-performance liquid chromatography, and the correlation between methods agreed well (R(2) = 0.9762). This system has successfully been applied to long-term, continuous determination and early warning for MC-LR in Lake Tai from June 2011 to May 2012. Thus, the AOBS paves the way for a vital routine online analysis that satisfies the high demand for ensuring the safety of drinking water sources. The AOBS can also serve as early warning system for accidental or intentional water pollution.
Collapse
Affiliation(s)
- Han-Chang Shi
- State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing, China.
| | | | | | | | | | | | | |
Collapse
|
15
|
Dixit RB, Suseela MR. Cyanobacteria: potential candidates for drug discovery. Antonie van Leeuwenhoek 2013; 103:947-61. [DOI: 10.1007/s10482-013-9898-0] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2012] [Accepted: 02/28/2013] [Indexed: 11/30/2022]
|
16
|
Liu M, Zhao H, Chen S, Yu H, Quan X. Colloidal graphene as a transducer in homogeneous fluorescence-based immunosensor for rapid and sensitive analysis of microcystin-LR. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2012; 46:12567-12574. [PMID: 23113735 DOI: 10.1021/es3028583] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Herein, we reported the assembly of colloidal graphene (CG) and microcystin (MC)-LR-DNA bioconjugates to develop a homogeneous competitive fluorescence-based immunoassay for rapid and sensitive detection of MC-LR in water samples. Initially, the MC-LR-DNA probe was quickly adsorbed onto the CG surface through the strong noncovalent π-π stacking interactions and can be effectively quenched benefiting from the high quenching efficiency of CG. In contrast, the competitive binding of anti-MC-LR with MC-LR-DNA destroyed the graphene/MC-LR-DNA interaction, thus resulting in the restoration of fluorescence signal. This signal transduction mechanism made it possible for analysis of the target MC-LR. Taking advantage of the colloidal nature of the as-prepared graphene, the assay was carried out in homogeneous solution throughout, which avoided numerous immobilization, incubation, and washing steps that were necessary to traditional heterogeneous immunoassays, thereby reducing the whole assay time (within less than 35 min) and allowing a much better antigen-antibody interaction. Moreover, due to the direct competitive mode, the assay did not involve any antibody labeling or modification process, which would be beneficial to preserve the binding affinity of antigen-antibody. Under optimal conditions, the proposed immunosensor can be applied for quantitative analysis of MC-LR with a detection limit of 0.14 μg/L, which satisfied the World Health Organization (WHO) provisional guideline limit of 1 μg/L for MC-LR in drinking water, thus providing a powerful tool for rapid and sensitive monitoring of MC-LR in environmental samples.
Collapse
Affiliation(s)
- Meng Liu
- School of Environmental Science and Technology, Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), Dalian University of Technology, Dalian, 116024, China
| | | | | | | | | |
Collapse
|
17
|
Hayama T, Katoh K, Aoki T, Itoyama M, Todoroki K, Yoshida H, Yamaguchi M, Nohta H. Liquid chromatographic determination of microcystins in water samples following pre-column excimer fluorescence derivatization with 4-(1-pyrene)butanoic acid hydrazide. Anal Chim Acta 2012; 755:93-9. [DOI: 10.1016/j.aca.2012.10.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2012] [Revised: 09/27/2012] [Accepted: 10/04/2012] [Indexed: 10/27/2022]
|
18
|
Queirós RB, Noronha JP, Marques PVS, Fernandes JS, Sales MGF. Determination of microcystin-LR in waters in the subnanomolar range by sol-gel imprinted polymers on solid contact electrodes. Analyst 2012; 137:2437-44. [PMID: 22436780 DOI: 10.1039/c2an35141b] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol-Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol-Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol-gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 × 10(-10) M, corresponding to 0.75 μg L(-1). It showed linear responses in the range of 7.7 × 10(-10) to 1.9 × 10(-9) M of MC-LR (corresponding to 0.77-2.00 μg L(-1)), thus including the limiting value for MC-LR in waters (1.0 μg L(-1)). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl(-)) showed limited interference while aluminium (Al(3+)), ammonium (NH(4)(+)), magnesium (Mg(2+)), manganese (Mn(2+)), sodium (Na(+)), and sulfate (SO(4)(2-)) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.
Collapse
Affiliation(s)
- Raquel B Queirós
- BioMark Sensor Research, Instituto Superior de Engenharia do Porto, R. Dr António Bernardino de Almeida, no. 431, 4200-072 Porto, Portugal
| | | | | | | | | |
Collapse
|
19
|
Herranz S, Marazuela M, Moreno-Bondi M. Automated portable array biosensor for multisample microcystin analysis in freshwater samples. Biosens Bioelectron 2012; 33:50-5. [DOI: 10.1016/j.bios.2011.12.016] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2011] [Revised: 12/04/2011] [Accepted: 12/10/2011] [Indexed: 10/14/2022]
|
20
|
Yu HW, Jang A, Kim LH, Kim SJ, Kim IS. Bead-based competitive fluorescence immunoassay for sensitive and rapid diagnosis of cyanotoxin risk in drinking water. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2011; 45:7804-11. [PMID: 21851106 DOI: 10.1021/es201333f] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Due to the increased occurrence of cyanobacterial blooms and their toxins in drinking water sources, effective management based on a sensitive and rapid analytical method is in high demand for security of safe water sources and environmental human health. Here, a competitive fluorescence immunoassay of microcystin-LR (MCYST-LR) is developed in an attempt to improve the sensitivity, analysis time, and ease-of-manipulation of analysis. To serve this aim, a bead-based suspension assay was introduced based on two major sensing elements: an antibody-conjugated quantum dot (QD) detection probe and an antigen-immobilized magnetic bead (MB) competitor. The assay was composed of three steps: the competitive immunological reaction of QD detection probes against analytes and MB competitors, magnetic separation and washing, and the optical signal generation of QDs. The fluorescence intensity was found to be inversely proportional to the MCYST-LR concentration. Under optimized conditions, the proposed assay performed well for the identification and quantitative analysis of MCYST-LR (within 30 min in the range of 0.42-25 μg/L, with a limit of detection of 0.03 μg/L). It is thus expected that this enhanced assay can contribute both to the sensitive and rapid diagnosis of cyanotoxin risk in drinking water and effective management procedures.
Collapse
Affiliation(s)
- Hye-Weon Yu
- School of Environmental Science and Engineering, Gwangju Institute of Science and Technology (GIST), 261 Cheomdan-gwagiro, Buk-gu, Gwangju 500-712, Republic of Korea
| | | | | | | | | |
Collapse
|
21
|
Ding Y, Mutharasan R. Highly sensitive and rapid detection of microcystin-LR in source and finished water samples using cantilever sensors. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2011; 45:1490-1496. [PMID: 21189000 DOI: 10.1021/es1020795] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Microcystin-leucine-arginine (MCLR) is one of the toxic microcystin congeners produced by the common cyanobacteria, blue-green algae. A piezoelectric-excited millimeter-sized cantilever (PEMC) sensor was developed for the sensitive detection of MCLR in a flow format using both monoclonal and polyclonal antibodies that bind specifically to MCLR. PEMC is a resonant cantilever sensor whose resonant frequency decreases as target analyte binds to its surface. Monoclonal antibody against MCLR was immobilized on the sensor surface via amine coupling. As the toxin in the sample water bound to the antibody, resonant frequency decreased proportional to toxin concentration. Three water matrices, namely buffer, tap water, and river water, were spiked with MCLR standards and were successfully detected in the dynamic range of 1 pg/mL to 100 ng/mL (effective concentration -250 fg/mL to 25 ng/mL). The sensor response was characterized by a log-linear relationship between resonant frequency change and MCLR concentration. Positive verification of MCLR detection was confirmed by a sandwich binding on the sensor with a second antibody binding to MCLR on the sensor (attached in first detection step) which caused a further resonant frequency decrease. We show for the first time that MCLR in various water samples can be detected at 1 pg/mL.
Collapse
Affiliation(s)
- Yanjun Ding
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, PA 19104, USA
| | | |
Collapse
|
22
|
An SPR biosensor for the detection of microcystins in drinking water. Anal Bioanal Chem 2010; 398:2625-34. [DOI: 10.1007/s00216-010-3856-8] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2010] [Revised: 05/14/2010] [Accepted: 05/17/2010] [Indexed: 11/26/2022]
|
23
|
Clavé G, Ronco C, Boutal H, Kreich N, Volland H, Franck X, Romieu A, Renard PY. Facile and rapid access to linear and truncated microcystin analogues for the implementation of immunoassays. Org Biomol Chem 2009; 8:676-90. [PMID: 20090987 DOI: 10.1039/b920193a] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A series of simplified microcystin-LR analogues based on Adda [(2S,3S,8S,9S,4E,6E)-3-amino-9-methoxy-2,6,8-trimethyl-10-phenyldecadienoic acid] or its corresponding aldol precursor linked to a polypeptide moiety have been synthesised and assessed for their binding affinity by the monoclonal antibody mAb MC159, an anti-microcystin-LR mAb recently selected by us for the detection of microcystins through various immunoassay formats. Some modifications have been brought to the enantiospecific synthesis of N-Boc-Adda developed by Pearson et al. (Org. Lett., 2000, 2, 2901) which enabled us to access in an economical and time-saving manner a small library of MC-LR linear analogues. Among which Adda was chosen to synthesise, as an illustrative example, a fluorescent probe derived from this beta-amino acid. This probe was subsequently solid-phase immobilised by means of oxime ligation in order to lead to biochips suitable for microcystin detection through the SPIT-FRI method.
Collapse
Affiliation(s)
- G Clavé
- Equipe de Chimie Bio-Organique, COBRA-CNRS UMR 6014 & FR 3038, rue Lucien Tesnière, 76131 Mont-Saint-Aignan, France
| | | | | | | | | | | | | | | |
Collapse
|
24
|
Sensitive and rapid chemiluminescence enzyme immunoassay for microcystin-LR in water samples. Anal Chim Acta 2009; 649:123-7. [DOI: 10.1016/j.aca.2009.07.026] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2009] [Revised: 07/06/2009] [Accepted: 07/08/2009] [Indexed: 11/20/2022]
|
25
|
Matrix Effects on the Microcystin-LR Fluorescent Immunoassay Based on Optical Biosensor. SENSORS 2009; 9:3000-10. [PMID: 22574059 PMCID: PMC3348817 DOI: 10.3390/s90403000] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2009] [Revised: 03/25/2009] [Accepted: 04/15/2009] [Indexed: 11/23/2022]
Abstract
Matrix effects on the microcystin-LR fluorescent immunoassay based on the evanescent wave all-fiber immunosensor (EWAI) and their elimination methods were studied. The results indicated that PBS and humic acid did not affect the monitoring of samples under the investigated conditions. When the pH was less than 6 or higher than 8, the fluorescence signals detected by immunosensor systems were obviously reduced with the decrease or increase of pH. When the pH ranged from 6 to 8, IC50 and the linear working range of MC-LR calculated from the detection curves were 1.01∼1.04 μg/L and 0.12∼10.5 μg/L, respectively, which was favourable for an MC-LR immunoassay. Low concentrations of Cu2+ rarely affected the detection performance of MC-LR. When the concentration of CuSO4 was higher than 5 mg/L, the fluorescence signal detected by EWAI clearly decreased, and when the concentration of CuSO4 was 10 mg/L, the fluorescence signal detected was reduced by 70%. The influence of Cu2+ on the immunoassay could effectively be compromised when chelating reagent EDTA was added to the pre-reaction mixture.
Collapse
|
26
|
Long F, He M, Zhu A, Shi H. Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples. Biosens Bioelectron 2009; 24:2346-51. [DOI: 10.1016/j.bios.2008.12.003] [Citation(s) in RCA: 98] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2008] [Revised: 12/01/2008] [Accepted: 12/03/2008] [Indexed: 11/30/2022]
|
27
|
A semi-quantitative dipstick assay for microcystin. Anal Bioanal Chem 2009; 394:863-9. [PMID: 19306114 DOI: 10.1007/s00216-009-2750-8] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2008] [Revised: 02/12/2009] [Accepted: 03/09/2009] [Indexed: 10/21/2022]
Abstract
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 microg x l(-1) (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
Collapse
|
28
|
Rapid chemiluminescence biosensing of microcystin-LR. Anal Chim Acta 2009; 636:218-23. [DOI: 10.1016/j.aca.2009.01.061] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2008] [Revised: 01/27/2009] [Accepted: 01/29/2009] [Indexed: 12/17/2022]
|
29
|
Loyprasert S, Thavarungkul P, Asawatreratanakul P, Wongkittisuksa B, Limsakul C, Kanatharana P. Label-free capacitive immunosensor for microcystin-LR using self-assembled thiourea monolayer incorporated with Ag nanoparticles on gold electrode. Biosens Bioelectron 2008; 24:78-86. [DOI: 10.1016/j.bios.2008.03.016] [Citation(s) in RCA: 105] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2007] [Revised: 03/18/2008] [Accepted: 03/18/2008] [Indexed: 11/15/2022]
|
30
|
A highly specific immunoassay for microcystin-LR detection based on a monoclonal antibody. Anal Chim Acta 2007; 603:111-8. [DOI: 10.1016/j.aca.2007.09.029] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2007] [Revised: 09/09/2007] [Accepted: 09/17/2007] [Indexed: 10/22/2022]
|
31
|
Sheng JW, He M, Shi HC, Qian Y. A comprehensive immunoassay for the detection of microcystins in waters based on polyclonal antibodies. Anal Chim Acta 2006; 572:309-15. [PMID: 17723494 DOI: 10.1016/j.aca.2006.05.040] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2006] [Revised: 05/11/2006] [Accepted: 05/12/2006] [Indexed: 11/22/2022]
Abstract
Microcystins (MCs) are a group of closely related toxic cyclic heptapeptides produced by common cyanobacteria (blue-green algae), and microcystin-leucine-arginine (MC-LR) is among the most frequent and most toxic microcystin congeners. In this study, a free amino group was introduced to MC-LR at its seventh amino acid residue with 2-mercaptoethylamine, and the product aminoethyl-MC-LR was coupled to bovine serum albumin (BSA) and horseradish peroxidise (HRP) by glutaraldehyde to be complete antigen (MC-LR-BSA) and labelled hapten (MC-LR-HRP), respectively. Polyclonal antibodies against MC-LR were generated by immunization with MC-LR-BSA. A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was established to detect the MCs in waters, which showed a good cross-reactivity with MC-LR, MC-RR, MC-YR, MC-LF, MC-LW and nodularin, and have a detection limit for MC-LR 0.12 microg L(-1), the 50% inhibition concentration (IC50) for MC-LR was 0.63+/-0.06 microg L(-1) and the quantitative detection range was from 0.17 to 2.32 microg L(-1), the analysis result of water samples showed good recovery and reliability. So the comprehensive and reliable dc-ELISA will well potentially suit for sensitive analysis for total MCs in drinking as well as resource water samples.
Collapse
Affiliation(s)
- Jian-Wu Sheng
- Environmental Simulation and Pollution Control, State Key Joint Laboratory, Department of Environmental Science and Engineering, Tsinghua University, Beijing 100084, China
| | | | | | | |
Collapse
|
32
|
Current awareness in phytochemical analysis. PHYTOCHEMICAL ANALYSIS : PCA 2005; 16:287-94. [PMID: 16042157 DOI: 10.1002/pca.796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
|